An?lise de linhas de fita n?o-homog?neas com camadas diel?tricas anisotr?picasAlbuquerque, Maria Rosa Medeiros Lins de 11 April 1985 (has links)
Made available in DSpace on 2014-12-17T14:55:34Z (GMT). No. of bitstreams: 1
MariaRMLA_da_capa_ate_pag_35.pdf: 6138605 bytes, checksum: 7f71c70a867f399ca2d557dfd94faa99 (MD5)
Previous issue date: 1985-04-11 / Abstract / A an?lise de linhas de fitas n?o-homog?neas com camadas diel?tricas anisotr?picas uniaxiais ? desenvolvida para uma formula??o quase-est?tica. Consideram-se o m?todo da equa??o integral, o m?todo do mapeamento e o m?todo da permissividade efetiva equivalente. O primeiro m?todo ? o mais geral, permitindo a an?lise diretamente das estruturas dadas. Nos outros dois m?todos, as estruturas dadas s?o transformadas em estruturas equivalentes com substratos isotr?picos. Curvas de imped?ncias caracter?sticas, velocidades de fase e permissividades efetivas s?o apresentadas para linhas de microfita: (a) invertidas, (b) suspensas, e (c) com camada superposta (com overlay). O efeito da espessura finita da fita condutora em linha de microfita convencional sobre substratos anisotr?picos ? tamb?m determinado, com uma maior simplicidade computacional. Observa-se concord?ncia com resultados de outros autores. As estruturas analisadas s?o adequadas ao desenvolvimento de circuitos de microondas, tais como: radiadores, bloqueadores, cc e acopladores direcionais
|
2 |
Prote??o de linhas de transmiss?o de corrente alternada baseada em ondas viajantes utilizando um terminalFran?a, Rafael Lucas da Silva 18 December 2017 (has links)
Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2018-04-02T12:36:23Z
No. of bitstreams: 1
RafaelLucasDaSilvaFranca_DISSERT.pdf: 613811 bytes, checksum: baf2e8237ca6f9e8738dd9414568a311 (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2018-04-04T13:41:29Z (GMT) No. of bitstreams: 1
RafaelLucasDaSilvaFranca_DISSERT.pdf: 613811 bytes, checksum: baf2e8237ca6f9e8738dd9414568a311 (MD5) / Made available in DSpace on 2018-04-04T13:41:29Z (GMT). No. of bitstreams: 1
RafaelLucasDaSilvaFranca_DISSERT.pdf: 613811 bytes, checksum: baf2e8237ca6f9e8738dd9414568a311 (MD5)
Previous issue date: 2017-12-18 / O Conselho Nacional de Desenvolvimento Cient?fico e Tecnol?gico - CNPq / Neste trabalho, os princ?pios da prote??o de ondas viajantes s?o investigados e dois
m?todos de prote??o de linhas de transmiss?o baseados em ondas viajantes utilizando um
terminal s?o propostos. O primeiro m?todo ? dependente da primeira reflex?o da onda
viajante, enquanto que o segundo ? baseado nas detec??es das ondas modais e n?o necessita
das reflex?es das ondas, entretanto, ? v?lido apenas para faltas envolvendo a terra.
O efeito da frequ?ncia de amostragem na prote??o ? equacionado, efeito esse, at? ent?o,
ainda n?o investigado para m?todos de um terminal. Em contraponto ?s altas frequ?ncias
de amostragem normalmente adotadas em m?todos baseados em um terminal, procedimentos
para a determina??o da m?nima frequ?ncia de amostragem s?o definidos. Al?m
disso, problemas cl?ssicos inerentes ? prote??o baseada em ondas viajantes, como a ocorr?ncia
de faltas pr?ximas aos terminais da linha e a estima??o da velocidade das ondas,
s?o detalhadamente equacionados e solu??es a tais problemas s?o apresentadas. Os m?todos
foram avaliados por meio de simula??es computacionais e os resultados demonstram
que possuem tempo de atua??o muito abaixo dos m?todos convencionais. Demonstram
tamb?m que o m?todo baseado nas reflex?es das ondas, apesar dos bons resultados obtidos,
pode apresentar dificuldades para sua aplica??o, uma vez que depende da correta
detec??o da onda refletida na falta, enquanto que o m?todo baseado em ondas modais ?
confi?vel, mas aplic?vel apenas ?s faltas que envolvem a terra. / In this work, the traveling wave protection principles are investigated and two oneterminal
transmission line protection method based on traveling waves are proposed. The
first method is dependent of the first wave reflection, whereas the second one is based on
modal waves detections and does not require wave reflections, however, is valid only to
earth-faults. The effect of the sampling frequency on the protection is considered, what
until then has not yet been investigated for one-terminal methods. In contrast to the high
sampling frequencies normally adopted in one-terminal-based methods, procedures for
determining the minimum sampling frequency are defined. In addition, classical problems
inherent to protection based on traveling waves, such as the occurrence of faults
near the line terminals and the estimation of the waves velocity, are detailed equated and
solutions to such problems are presented. The methods were evaluated by means of computational
simulations and the results show that they have an operation time far below the
conventional methods. They also demonstrate that the method based on the wave reflections,
despite the good results obtained, can present difficulties for its application, since it
depends on the correct detection of the wave reflected in the fault point, since the method
based on modal waves is reliable, but applicable only to earth-faults.
|
3 |
Metodologia de estima??o de estados para tratamento de medi??es err?neas e registros n?o sincronizados em algoritmos de localiza??o de faltas em linhas de transmiss?oCruz, Melinda Cesianara Silva da 17 July 2015 (has links)
Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2016-04-22T21:41:53Z
No. of bitstreams: 1
MelindaCesianaraSilvaDaCruz_TESE.pdf: 2034495 bytes, checksum: a7bdc7bc74326370650126bf74a096da (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2016-04-22T22:11:02Z (GMT) No. of bitstreams: 1
MelindaCesianaraSilvaDaCruz_TESE.pdf: 2034495 bytes, checksum: a7bdc7bc74326370650126bf74a096da (MD5) / Made available in DSpace on 2016-04-22T22:11:02Z (GMT). No. of bitstreams: 1
MelindaCesianaraSilvaDaCruz_TESE.pdf: 2034495 bytes, checksum: a7bdc7bc74326370650126bf74a096da (MD5)
Previous issue date: 2015-07-17 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior (CAPES) / O desempenho de algoritmos para localiza??o de faltas em linhas de transmiss?o est? diretamente relacionado ? exatid?o dos seus dados de entrada. Assim, fatores como erros nos par?metros da linha de transmiss?o, falhas na sincroniza??o de registros oscilogr?ficos e erros em medi??es de tens?o e de corrente podem influenciar de forma significativa as ferramentas que usam dados err?neos para indicar o local de defeitos. Este trabalho apresenta uma nova metodologia para localiza??o de faltas em linhas de transmiss?o, baseada na teoria de estima??o de estados, de forma a determinar o local mais prov?vel de ocorr?ncia de curtos-circuitos atrav?s da considera??o de erros sistem?ticos real?sticos que podem estar presentes nas medi??es de tens?o e de corrente. O algoritmo foi implementado em duas etapas: pr?-falta e p?s-falta. Na primeira etapa, admitindo dados n?o sincronizados, estima-se o ?ngulo de sincroniza??o e os par?metros de sequ?ncia positiva da linha de transmiss?o, e na segunda, estima-se a dist?ncia de falta. Al?m de calcular o valor mais prov?vel para a dist?ncia de falta, a partir da considera??o de erros nas medi??es, a vari?ncia associada a esta dist?ncia tamb?m ? determinada, usando defini??es da teoria de erros. Essa ? uma das principais contribui??es deste trabalho, visto que, a partir o algoritmo proposto, ? poss?vel determinar uma regi?o de prov?vel incid?ncia da falta, com aproximadamente 95,45% de confian?a. Testes para avalia??o e valida??o da metodologia foram realizados a partir de registros reais de falta e a partir de simula??es de sistemas fict?cios de transmiss?o no software ATP. Os resultados obtidos s?o relevantes para mostrar que o estimador de localiza??o de faltas desenvolvido apresenta bom desempenho mesmo adotando vari?ncias real?sticas. / The performance of algorithms for fault location i
n transmission lines is directly
related to the accuracy of its input data. Thus, fa
ctors such as errors in the line parameters,
failures in synchronization of oscillographic recor
ds and errors in measurements of voltage
and current can significantly influence the accurac
y of algorithms that use bad data to indicate
the fault location. This work presents a new method
ology for fault location in transmission
lines based on the theory of state estimation in or
der to determine the location of faults more
accurately by considering realistic systematic erro
rs that may be present in measurements of
voltage and current. The methodology was implemente
d in two stages: pre-fault and post-
fault. In the first step, assuming non-synchronized
data, the synchronization angle and
positive sequence line parameters are estimated, an
d in the second, the fault distance is
estimated. Besides calculating the most likely faul
t distance obtained from measurement
errors, the variance associated with the distance f
ound is also determined, using the errors
theory. This is one of the main contributions of th
is work, since, with the proposed algorithm,
it is possible to determine a most likely zone of f
ault incidence, with approximately 95,45%
of confidence. Tests for evaluation and validation
of the proposed algorithm were realized
from actual records of faults and from simulations
of fictitious transmission systems using
ATP software. The obtained results are relevant to
show that the proposed estimation
approach works even adopting realistic variances, c
ompatible with real equipments errors.
|
4 |
Localiza??o de faltas em linhas de transmiss?o de m?ltiplos terminais a partir de registros oscilogr?ficos sincronizados via transformada waveletCruz, Melinda Cesianara Silva da 06 August 2010 (has links)
Made available in DSpace on 2014-12-17T14:55:45Z (GMT). No. of bitstreams: 1
MelindaCSC_DISSERT.pdf: 967257 bytes, checksum: 22530a2989a1b62dc6a9df7bffa70ed3 (MD5)
Previous issue date: 2010-08-06 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior / The electric energy is essential to the development of modern society and its increasing
demand in recent years, effect from population and economic growth, becomes the companies
more interested in the quality and continuity of supply, factors regulated by ANEEL (Ag?ncia
Nacional de Energia El?trica). These factors must be attended when a permanent fault occurs
in the system, where the defect location that caused the power interruption should be
identified quickly, which is not a simple assignment because the current systems complexity.
An example of this occurs in multiple terminals transmission lines, which interconnect
existing circuits to feed the demand. These transmission lines have been adopted as a feasible
solution to suply loads of magnitudes that do not justify economically the construction of new
substations. This paper presents a fault location algorithm for multiple terminals transmission
lines - two and three terminals. The location method is based on the use of voltage and current
fundamental phasors, as well as the representation of the line through its series impedance.
The wavelet transform is an effective mathematical tool in signals analysis with
discontinuities and, therefore, is used to synchronize voltage and current data. The Fourier
transform is another tool used in this work for extract voltage and current fundamental
phasors. Tests to validate the location algorithm applicability used data from faulty signals
simulated in ATP (Alternative Transients Program) as well as real data obtained from
oscillographic recorders installed on CHESF s lines. / A energia el?trica ? indispens?vel para o desenvolvimento da sociedade moderna e sua
crescente demanda nos ?ltimos anos, fruto dos crescimentos populacional e econ?mico, fez
com que as concession?rias se tornassem mais comprometidas com a qualidade e a
continuidade do fornecimento, fatores que s?o regulamentados pela ANEEL (Ag?ncia
Nacional de Energia El?trica). Para que esses fatores sejam atendidos quando ocorre uma falta
permanente no sistema, faz-se necess?ria, primeiramente, uma r?pida localiza??o do defeito
causador da interrup??o da energia, o que n?o ? uma tarefa t?o simples devido ?
complexidade dos sistemas atuais. Um exemplo disso ocorre nas linhas de transmiss?o com
m?ltiplos terminais, que interligam circuitos existentes com objetivo de atender ? demanda.
Nestas linhas, deriva??es para atender a cargas de porte que n?o justificam economicamente a
constru??o de novas subesta??es s?o adotadas como medidas vi?veis para aliviar outros
circuitos. Este trabalho prop?e um algoritmo de localiza??o de faltas que ? aplicado em linhas
de transmiss?o com m?ltiplos terminais dois e tr?s terminais. O m?todo de localiza??o
baseia-se no uso de fasores fundamentais de tens?o e corrente, bem como na representa??o da
linha atrav?s de sua imped?ncia s?rie. A Transformada Wavelet ? uma ferramenta matem?tica
eficaz na an?lise de descontinuidades de sinais e, por este motivo, ? utilizada na sincroniza??o
dos dados de tens?o e corrente oriundos de faltas. A transformada de Fourier ? outra
ferramenta utilizada neste trabalho para extra??o dos fasores fundamentais de tens?o e
corrente. Para testar e validar a aplicabilidade do algoritmo de localiza??o, utilizaram-se
dados de sinais faltosos simulados no ATP (Alternative Transients Program) e tamb?m dados
reais obtidos de registradores oscilogr?ficos instalados em linhas da CHESF.
|
5 |
Localiza??o de faltas em linhas de transmiss?o usando morfologia matem?tica / Location of Fault Lines Transmission using Mathematical MorphologyCavalcante, Paulo Anderson Holanda 19 April 2011 (has links)
Made available in DSpace on 2015-03-03T15:07:33Z (GMT). No. of bitstreams: 1
PauloAHC_DISSERT.pdf: 3758465 bytes, checksum: 6b6aaaf4f22bae19573b264eb2e88629 (MD5)
Previous issue date: 2011-04-19 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior / This work an algorithm for fault location is proposed. It contains the following functions:
fault detection, fault classification and fault location. Mathematical Morphology
is used to process currents obtained in the monitored terminals. Unlike Fourier
and Wavelet transforms that are usually applied to fault location, the Mathematical
Morphology is a non-linear operation that uses only basic operation (sum, subtraction,
maximum and minimum). Thus, Mathematical Morphology is computationally very
efficient.
For detection and classification functions, the Morphological Wavelet was used.
On fault location module the Multiresolution Morphological Gradient was used to
detect the traveling waves and their polarities. Hence, recorded the arrival in the two
first traveling waves incident at the measured terminal and knowing the velocity of
propagation, pinpoint the fault location can be estimated.
The algorithm was applied in a 440 kV power transmission system, simulated on
ATP. Several fault conditions where studied and the following parameters were evaluated:
fault location, fault type, fault resistance, fault inception angle, noise level and
sampling rate. The results show that the application of Mathematical Morphology in
faults location is very promising / Neste trabalho, um algoritmo de localiza??o de faltas ? desenvolvido, consistindo
dos m?dulos de detec??o, classi ca??o e localiza??o da falta. Na implementa??o do
algoritmo a Morfologia Matem?tica ser? a ferramenta utilizada para analisar os sinais
das correntes obtidas em um dos terminais da linha. Diferente das Transformadas de
Fourier e Wavelet que s?o normalmente aplicadas ? localiza??o de faltas, a Morfologia
Matem?tica ? uma transforma??o n?o linear baseada apenas em opera??es de adi??o
e subtra??o acompanhadas da extra??o de m?ximos e m?nimos de conjuntos discretos.
Portanto, a Morfologia Matem?tica apresenta a vantagem de ser computacionalmente
bastante e ciente.
Nos m?dulos de detec??o e classi ca??o a Wavelet Morfol?gica foi usada na extra??o
de informa??es contidas nas baixas e nas altas frequ?ncias. No m?dulo de localiza??o
da falta o ltro Gradiente Morfol?gico Multirresolu??o foi utilizado na detec??o dos
instantes de chegada das ondas viajantes e na determina??o de suas polaridades. A
partir dos instantes de chegada das duas primeiras ondas viajantes incidentes no terminal
de medi??o e da velocidade de propaga??o dessas ondas, a localiza??o da falta
pode ser estimada com precis?o.
Para analisar o desempenho do algoritmo, um sistema de transmiss?o de 440 kV
simulado no software ATP foi submetido ? diversas circunst?ncias de falta, variandose
par?metros como: dist?ncia da falta, tipo da falta, resist?ncia da falta, ?ngulo de
incid?ncia da falta, n?vel de ru?dos e frequ?ncia de amostragem dos sinais. Os resultados
obtidos mostram que a aplica??o da Morfologia Matem?tica na localiza??o de faltas ?
bastante promissora
|
6 |
Estima??o de Fasores para Prote??o de Sistemas El?tricos Baseada em M?nimos Quadrados e Morfologia Matem?ticaFormiga, Diego Alves 18 December 2012 (has links)
Made available in DSpace on 2014-12-17T14:56:16Z (GMT). No. of bitstreams: 1
DiegoAF_DISSERT.pdf: 1045785 bytes, checksum: 38dd893df9531c8e71f483fc22aa3802 (MD5)
Previous issue date: 2012-12-18 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior / This work proposes a new technique for phasor estimation applied in microprocessor
numerical relays for distance protection of transmission lines, based on the recursive least
squares method and called least squares modified random walking. The phasor estimation
methods have compromised their performance, mainly due to the DC exponential
decaying component present in fault currents. In order to reduce the influence of the
DC component, a Morphological Filter (FM) was added to the method of least squares
and previously applied to the process of phasor estimation. The presented method is implemented
in MATLABr and its performance is compared to one-cycle Fourier technique
and conventional phasor estimation, which was also based on least squares algorithm. The
methods based on least squares technique used for comparison with the proposed method
were: forgetting factor recursive, covariance resetting and random walking. The techniques
performance analysis were carried out by means of signals synthetic and signals
provided of simulations on the Alternative Transient Program (ATP). When compared to
other phasor estimation methods, the proposed method showed satisfactory results, when
it comes to the estimation speed, the steady state oscillation and the overshoot. Then,
the presented method performance was analyzed by means of variations in the fault parameters
(resistance, distance, angle of incidence and type of fault). Through this study,
the results did not showed significant variations in method performance. Besides, the apparent
impedance trajectory and estimated distance of the fault were analysed, and the
presented method showed better results in comparison to one-cycle Fourier algorithm / Prop?e-se neste trabalho uma nova t?cnica de estima??o fasorial, a ser utilizada em
rel?s num?ricos microprocessados digitais para prote??o de dist?ncia de linhas de transmiss?o,
baseada no m?todo dos m?nimos quadrados recursivo, denominada m?nimos quadrados
em caminhada aleat?ria modificada. Os m?todos de estima??o fasorial t?m seu
desempenho comprometido devido, principalmente, ? componente DC de decaimento exponencial
presente nas correntes de falta. Para reduzir a influ?ncia da componente DC,
agregou-se ao m?todo de m?nimos quadrados um Filtro Morfol?gico (FM) aplicado previamente
ao processo de estima??o fasorial. O m?todo apresentado foi implementado
em ambiente MATLABr e o seu desempenho comparado aos m?todos convencionais de
estima??o fasorial, tamb?m baseados em m?nimos quadrados, e ao algoritmo de Fourier
de um ciclo. Os m?todos baseados na t?cnica de m?nimos quadrados utilizados para
compara??o com o m?todo proposto foram: recursivo ponderado, com reinicializa??o da
covari?ncia e caminhada aleat?ria. As an?lises de desempenho das t?cnicas foram realizadas
por meio de sinais sint?ticos e sinais oriundos de simula??es no Alternative Transient
Program (ATP). Em compara??o aos demais m?todos de estima??o fasorial, o m?todo
proposto apresentou resultados satisfat?rios no que se refere ? velocidade de resposta, oscila??o
em regime permanente e percentual de overshoot. Em seguida, o m?todo proposto
teve seu desempenho analisado frente ?s varia??es nos par?metros de falta (resist?ncia,
dist?ncia, ?ngulo de incid?ncia e tipo de falta). Nesse estudo, constatou-se que o m?todo
n?o sofreu varia??es significativas em seus resultados. Al?m disso, analisou-se a trajet?ria
da imped?ncia aparente e dist?ncia estimada da falta, ao qual o m?todo proposto
apresentou melhores resultados em compara??o ao algoritmo de Fourier de um ciclo
|