• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 76
  • 1
  • Tagged with
  • 77
  • 77
  • 67
  • 64
  • 49
  • 39
  • 21
  • 20
  • 17
  • 15
  • 14
  • 14
  • 13
  • 13
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Microbiologia e cinética de sistema de lodos ativados como pós-tratamento de efluente de reator anaeróbio de leito expandido / Microbiology and kinetic of activated sludge system as post treatment of expanded bed anaerobic reactor

Luciana Coêlho Mendonça 22 November 2002 (has links)
Os principais objetivos deste trabalho foram analisar o desempenho de sistema combinado (escala piloto), constituído por reator anaeróbio de leito expandido (Ralex) seguido por sistema de lodos ativados, utilizado no tratamento de esgoto sanitário, correlacionar as características da microbiota do sistema de lodos ativados com os resultados físico-químicos e determinar a cinética de consumo de substrato no sistema de lodos ativados. O desempenho do sistema combinado quanto à remoção de DQO total e DQO filtrada foi de 82% e 80%, respectivamente. No sistema combinado, a remoção de nitrogênio total foi de 65% e a remoção de fósforo foi de 35%. A população de protozoários foi bem diversificada, sendo condizente com as características operacionais do sistema de lodos ativados. Arqueas metanogênicas foram capazes de sobreviver no tanque de aeração, porém em número reduzido. O modelo cinético que melhor representou a degradação de DQO filtrada, no sistema de lodos ativados, foi o de primeira ordem com residual. A constante aparente específica média foi de 0,05L/gSSV.dia. Nas condições estudadas, não ficou evidenciado o efeito da temperatura na cinética, provavelmente devido à resistência de transferência de massa. / The major objectives of this study were: (i) to evaluate the performance of a combined system (pilot scale) treating wastewater, composed by an expanded bed anaerobic reactor and an activated sludge system; (ii) to correlate microorganisms characteristics of the activated sludge system with the physical-chemical results; and (iii) to determinate the substrate consumption kinetics of the activated sludge system. The performance of the combined system in terms of total and filtrated COD was 82% and 80% respectively. Total nitrogen removal was 65% and total phosphorous removal was 35%, in the combined system. Protozoa populations were well diversified, according to operational characteristics of activated sludge. Methanogenics archeas survived into aeration tank, but in a reduced number. First order with residual kinetic model represented the filtered COD degradation, in the activated sludge system. The mean apparent specific constant was 0,05L/gVSS.day. In this study, the effect of temperature on kinetics was not evident, probably due to mass transfer resistance.
62

Definição do ciclo operacional de um reator seqüencial em batelada aeróbio (SBR) para tratamento de esgoto sanitário / Definition of the operational cycle of an aerobic sequencing batch reactor (SBR) for the treatment of sanitary sewage

Rodrigo Gibbin Marconi 19 January 2001 (has links)
No processo de lodos ativados por batelada, a definição de um ciclo operacional é de fundamental importância para o bom funcionamento de uma estação de tratamento de esgotos que utiliza esse tipo de tratamento. A adoção de um ciclo adequado pode trazer vários benefícios como o aumento da eficiência de tratamento, a introdução da remoção da matéria nitrogenada, por meio dos processos de nitrificação e desnitrificação do efluente e até diminuir o consumo de energia que é relativamente alto nesse tipo de tratamento. Foi aplicada então, a definição do ciclo operacional à ETE Bueno de Andrada que utiliza o processo de lodos ativados por batelada aeróbio para o tratamento da fase líquida. Foram experimentados alguns ciclos de operação com tempos e estratégias diferentes, variando-se os tempos de aeração, mistura, enchimento ou sedimentação. A aplicabilidade de cada estratégia de ciclo foi avaliada em termos da eficiência de remoção da matéria orgânica carbonácea, retratada com as análises de DBO e DQO do esgoto afluente e do efluente final. Foi desenvolvido também, o processo de automação da ETE Bueno de Andrada com o estudo e ajuste de um programa computacional que gera um arquivo de controle utilizado para controle do ciclo de operação dos SBRs. Os resultados mostraram que os ciclos operacionais entre 10 e 12h, consegue-se uma eficiência de remoção da matéria orgânica carbonácea entre 95 e 97%. / The definition of an adequate operational cycle for the batch activated sludge process is of fundamental importance for the proper operation of a sewage treatment plant. The use of a suitable cycle can bring many benefits namely the increase of the treatment efficiency, the introduction of the nitrogen organic material removal through the nitrification and denitrification process of the eflluent and the decrease of energy consumption that is relatively high in this process. The operational cycle definition is then applied to the Sewage Treatment Plant of Bueno de Andrada that use the aerobic batch activated sludge process for the liquid phase treatment. Some operational cycles are experimented with different times and strategies, changing the aeration, rnixture, filling or sedimentation times. The applicability of each cycle strategy was checked by the carbon organic material removal efficiency, measured through the BOD and COD analyses of the influent sewage and the treated eflluent. It was developed, too, the automation process of the Sewage Treatment Plant of Bueno de Andrada, cornplementing and adjusting the control computer program for the PLC that controls the SBRs operational cycle. The results showed that with operational cycles between 10 and 12 hours, the removal efficiency of the carbon organic material was between 95 and 97%.
63

Avaliação do tratamento combinado de lixiviado de aterro sanitário e esgoto sanitário em sistema de lodos ativados / Evaluation of the combined treatment of landfill leachate and domestic sewage in activated sludge system

Edilincon Martins de Albuquerque 05 June 2012 (has links)
Um dos principais resíduos gerados nos aterros é o lixiviado, que possui elevada concentração de matéria orgânica biodegradável e refratária e de matéria inorgânica, como nitrogênio amoniacal e metais pesados. O tratamento combinado de lixiviado com esgoto sanitário tem sido utilizado em algumas estações de tratamento de esgoto (ETE) brasileiras. No entanto, o processo ainda sofre vários questionamentos e incertezas, especialmente sobre os efeitos da adição do lixiviado sobre o sistema de tratamento. Nesse contexto, o presente trabalho visou avaliar a eficiência do tratamento combinado de lixiviado/esgoto em sistema de lodos ativados, em diferentes condições. Na primeira etapa desta pesquisa, foram realizados experimentos de tratabilidade em escala de bancada (regime de batelada) utilizando as proporções volumétricas de 0% (controle), 0,2%, 2% e 5% de lixiviado em diferentes condições experimentais. Dentre eles, o Experimento 2 (lixiviado pré-tratado por alcalinização e air stripping) se mostrou mais viável tecnicamente, alcançando eficiências de remoção da DBO, da DQO e do COD acima de 97, 82, 60%, respectivamente, até a proporção de 2% de lixiviado pré-tratado. Na segunda etapa da pesquisa, foi avaliada a tratabilidade utilizando reatores em escala piloto (regime contínuo) tratando esgoto sanitário com 2% (P1) e 0% (P2-controle) de lixiviado pré-tratado, com relação microrganismo-alimento de 0,22 kgDBO/kgSSV.dia, tempo de detenção hidráulica de 24 horas e idade do lodo de 20 dias. Os resultados indicaram viabilidade do tratamento nas condições estudadas com 2% de lixiviado pré-tratado, cujas eficiências médias de remoção da DBO, da DQO, do COD foram de 93, 84 e 60%, respectivamente. Esta pesquisa foi desenvolvida com apoio financeiro (Processo N° 2010/51955-2) da Fundação de Amparo à Pesquisa de São Paulo (FAPESP). / The leachate is one of the main wastes generated in landfills, it has a high concentration of biodegradable and refractory organic matter and inorganic matter, such as ammonia and heavy metals. The combined treatment of leachate with sewage has been used in various sewage treatment plants in Brazil. However, there are still many questions and uncertainties about the process, especially the effects of adding leachate on the treatment system. In this context, this study aimed at evaluating the efficiency of combined treatment of leachate/sewage in activated sludge under different conditions. In the first stage of this research, treatability experiments were carried out in a bench scale (SBR) using the volumetric proportions of 0% (control), 0.2%, 2% and 5% leachate under different experimental conditions. The Experiment 2 (leachate pretreated by alkalinization and air stripping) was more technically feasible, achieving efficiencies of removal of BOD, COD and DOC above 97, 82, 60%, respectively, until the proportion of 2% pre-treated leachate. In the second stage of the research was evaluated the treatability using pilot-scale reactors (continuous flow) for sewage treatment with 2% (P1) and 0% (P2-control) leachate pretreated. The operational parameters adopted were food-microorganism rate of 0.22 kgDBO/ kgSSV.d, hydraulic retention time of 24 hours and the sludge retention time of 20 days. The results indicated the viability of the combined treatment with 2% leached pretreated, whose average efficiency of removing BOD, COD, DOC were 93, 84 and 60% respectively. This research was developed with financial support (case No. 2010/2-51955) of Fundação de Amparo à Pesquisa de São Paulo (FAPESP).
64

Estudo da tratabilidade das soluções de lactose com ácidos húmicos e lactose com lixiviado de aterro sanitário por lodos ativados em escala de bancada

Rafaella Campos 20 March 2013 (has links)
O lixiviado de aterro sanitário é uma água residuária com elevada concentração de DQO, DBO, amônia, traços de metais pesados e substâncias orgânicas dificilmente biodegradáveis, tais como substâncias húmicas e celulósicas (lignina). Dada essas características, torna-se necessário que ele seja recolhido e devidamente tratado para evitar danos ao meio ambiente e à saúde humana. Uma prática que tem sido adotada por alguns municípios brasileiros é o direcionamento do lixiviado para tratamento consorciado em estações de tratamento de esgoto (ETE). No entanto, são poucos os estudos que avaliam a eficácia desse procedimento. Um dos questionamentos sobre o tratamento biológico diz respeito à remoção do material orgânico dificilmente biodegradável, representado principalmente pelas substâncias húmicas e, dentro dessa classe, destaca-se a fração de ácidos húmicos no lixiviado. Nesse contexto, o presente trabalho teve como objetivo verificar a tratabilidade das soluções contendo lactose, lactose com ácidos húmicos, lactose com 2% em volume de lixiviado de aterro sanitário bruto e lactose com 2% em volume de lixiviado pré-tratado por \"air stripping\", quando submetidas ao tratamento biológico em reatores de lodos ativados em escala de bancada. Assim, buscou-se verificar se essa tecnologia de tratamento é capaz de estabilizar, ainda que parcialmente, compostos orgânicos de difícil biodegradação presentes no lixiviado. A quantificação das substâncias de difícil biodegradação antes e após o tratamento foi realizada pelo método tentativo do \"Equivalente em Ácidos Húmicos\" que se encontra em fase de estudo. Os resultados demonstraram que houve uma remoção parcial dessas substâncias. As análises de espectroscopia na região do infravermelho indicaram que não ocorreu a adsorção dos ácidos húmicos no lodo, o que pode ser uma evidencia de que a redução da concentração dessas substâncias é de fato devida ao seu consumo e não pela precipitação no lodo. Além disso, a adição de 2% em volume do lixiviado não ocasionou redução da população de microrganismos no sistema. / Leachate from sanitary landfills is a type of effluent with high concentrations of COD, BOD, ammonia, heavy metal traces and hardly biodegradable organic compounds such as humic and cellulosic substances (lignin). Thus this effluent needs to be collected and treated in order to prevent damages to the environment and to human health. A common practice in Brazilian cities is to destine the leachate to a sewage treatment plant (STP). However, there are few studies that assess the efficiency of this procedure. One of the questions regarding the biological treatment concerns its efficiency in removing hardly biodegradable organic compounds, represented in the most part by the humic substances, given the high levels of humic acid in the leachate. Within this context, the present study had the objective to verify the treatability of solutions containing lactose, lactose with humic acids, lactose with 2% (in volume) of untreated sanitary landfill leachate, and lactose with 2% of leachate pre-treated by air stripping, submitted to biological treatment in laboratory-scale activated sludge reactors. Thus this paper assessed if such treatment technology can stabilize, even if only partially, the hardly biodegradable organic compounds found in leachate. The quantification of these substances prior to and after treatment was made by using a tentative method called Humic Acids Equivalent, which is still in the phase of studies. The results show that there was a partial removal of these substances. The spectroscopy analyses on the infrared region indicated that there was no adsorption of humic acids onto the sludge, which evidences that the decrease in the levels of these substances was due to their consumption and not precipitation onto the sludge. Also, the addition of 2% of leachate did not reduce the population of microorganisms in the system.
65

Comparação da estrutura de comunidades microbianas presentes em sistemas de lodos ativados modificados para remoção biológica do fósforo em excesso, utilizando a técnica de eletroforese em gel de gradiente desnaturante (DGGE) / Comparison of the microbial communities structure in systems of activated sludge modified for enhanced biological phosphorus removal by denaturing gradient gel electrophoresis technique (DGGE)

Isabel Kimiko Sakamoto 30 October 2001 (has links)
O excesso de nutrientes como nitrogênio e fósforo em efluentes de estação de tratamento de esgoto sanitário pode provocar a eutrofização nos corpos d\'aguas receptoras. Esse processo gera efeitos negativos para a engenharia sanitária, dependendo do grau de qualidade e do uso de água requeridos. Para o abastecimento público, são exigidos métodos e processos de tratamentos avançados, quando a fonte hídrica está eutrofizada. Neste sentido, sistemas aeróbios de lodos ativados passaram a se destacar também como removedores de nutrientes por processos biológicos, após sofrerem algumas modificações operacionais. Um meio para otimizar o processo de remoção biológica do fósforo em excesso (EBPR) é promover condições ideais para o crescimento dos organismos acumuladores de fósforo. Esse trabalho teve como objetivo avaliar uma estação piloto de lodos ativados modificados, para a remoção de fósforo em excesso, utilizados no tratamento de esgoto sanitário, localizada na ETE da cidade de Tóquio - Japão. Essa estação piloto constituía-se de três sistemas de reação (1, 2 e 3), sendo que cada sistema era compartimentado e submetido às condições anaeróbia, anóxica e aeróbia. A avaliação dos três sistemas de reação, consistiu na verificação do desempenho deles com relação a DBO e fósforo e monitoramento da estrutura da comunidade microbiana, pela técnica da eletroforese em gel de gradiente desnaturante (DGGE). O desempenho em relação a DBOs (mg/L) nos três sistemas de reação, sempre foi superior a 90% e a eficiência da remoção do fósforo (%) na forma de fosfato (P-PO4 - mg/L) foi superior, em geral, a 70%, considerando os valores de entrada das alimentações e saída no último compartimento dos três sistemas de reação. Verificou-se que a estrutura da comunidade microbiana apresentou uma grande diversidade, devido aos números de bandas padrões encontradas nas amostras analisadas. Observou-se também uma grande similaridade ) da estrutura da comunidade microbiana nos sistemas estudados, possivelmente, relacionada ao mesmo afluente (esgoto sanitário) e ao mesmo tipo de recirculação interna e do lodo. As mudanças das estruturas das comunidades microbianas foram pequenas, diante das mudanças temporais e operacionais. No entanto, observou-se que o sistema foi menos eficiente (parâmetros de desempenho), frente a essas mudanças, o que pode estar mais relacionado à redução das atividades dos microrganismos do que com as estruturas microbianas. / The excess of nutrients such as nitrogen and phosphate in effluents of treatment plants for sanitary sewage can cause eutrophication in the receiving body of water. Given that process generates negative effects for the sanitary engineering depending on the degree of the quality and of the requested use of water. For the public provisioning, methods and processes of advanced treatments are demanded, when the water body is eutrophic. In this sense, aerobic systems of activated sludge have been expanded also to the processes of biological removal of nutrients after some operational modifications. By means of the optimization process of enhanced biological phosphorus removal (EBPR) will promote ideal conditions for the growth of polyphosphate accumulating organisms. This work had as its objective to evaluate a pilot station modified activated sludge, used for the treatment of sanitary sewage, but specifically for the enhanced phosphorus removal, located in the ETE of the city of Tokyo - Japan. These pilot station was constituted of three reaction systems (1, 2 and 3), and each system were composed of compartments and were submitted to anaerobic, anoxic and aerobic conditions. The evaluation of the three reaction systems, consisted of the verification of the performance of the systems with regard to BOD and phosphate which were monitored through microbial community\'s structure, for the biological phosphorus removal technique (DGGE). The performance in relation to the BODS (mg/L) in the three reaction systems was always above 90% and the efficiency of the removal of phosphorus (%) in the form of phosphate (P-PO4 - mg/L) was in general better than 70%, considering the values of influent and effluent from the last compartment of the three reaction systems. It was verified that the microbial community structure presented a great diversity, due to the standard numbers of bands found in the analyzed samples. A great similarity of the microbial community structure was observed in the studied systems, possibly being related to the same influent (domestic sewage) and to the same type of intern recirculation and of the sludge. The changes of the microbial communities structures were small, before the temporary and operational changes. However, it was observed that the system was less effiecient (performance parametrs) front to those changes, what can be more related the reduction of the activities of the microorganisms than with the microbial structures.
66

Remoção de cistos de Giardia spp. e de Cryptosporidium spp. em sistema de tratamento de esgoto sanitário: quantificação em fases líquida e sólida / Removal of Giardia spp. cysts and Cryptosporidium spp. oocists in wastewater treatment systems: quantification in liquid and solid fases

Eraldo Kobayashi dos Santos 25 September 2015 (has links)
No atual cenário de saneamento, há uma escassez de estudos na temática de retenção de microrganismos patogênicos em estações de tratamento de esgotos, onde os principais tratamentos se baseiam na remoção de parâmetros físico-químicos. Uma abordagem mais ampla na remoção destes microrganismos em estações de tratamento e sua quantificação no lodo retido é um passo importante para o aumento do debate acerca da eficiência dos atuais tratamentos utilizados na retenção de patógenos, diminuindo assim a contaminação de corpos d\'água com posteriores problemáticas no âmbito de saúde pública. Desta forma, a proposta do projeto foi avaliar e quantificar a remoção de cistos de Giardia spp., oocistos de Cryptosporidium spp. e Escherichia Coli em sistema de tratamento de esgoto sanitário constituído de tratamento anaeróbio (reator UASB), utilizando dois valores de TDH - 8 horas (Etapa 1) e 12 horas (Etapa 2) - seguido de tratamento em sistema de lodo ativado. O projeto utilizou uma estação de tratamento piloto junto a estação de tratamento da USP São Carlos. Para análises de E. coli e coliformes totais foi utilizada a técnica de pour plate e para detecção de cistos e oocistos de Giardia spp. e Cryptosporidium spp., a técnica de separação imunomagnética (IMS) e técnica de Reação de Imunoflorescência Direta (RID) foi escolhida como método de detecção e quantificação. Para a remoção no reator UASB, a variação de TDH indicou influência na remoção de parâmetros físico-químicos e na retenção de microrganismos, sendo que a utilização de TDH de 12 horas obteve remoções de 0,21 log para cistos Giardia spp. e 0,48 log para oocistos de Cryptosporidium spp. Para o Sistema de Lodo ativado, as remoções foram de 0,48 log e 0,15 para ambos os microrganismos, respectivamente, não havendo influência significativa na retenção com a mudança de TDH do reator UASB. Nas análises em fase sólida, foram observados valores altos de contaminação no lodo, tanto para Giardia spp., quanto para Cryptosporidium spp., onde a viabilidade dos (oo)cistos detectados estiveram na faixa de 30% a 99% nas amostras analisadas. / Currently, the field of sanitation faces a lack of studies on retention of pathogenic microorganisms in wastewater treatment plants, where main treatments are based on the removal of physical and chemical parameters. A broader approach to the removal of pathogens in wastewater treatment systems and their quantification in retained sludge is an important step to increase the debate around the efficiency of prevailing treatments used to retain those microorganisms and to consequently reduce the contamination of water bodies. The present study was conducted to assess and quantify the removal of Giardia spp. cysts, Cryptosporidium spp. oocysts and E. coli in wastewater treatment systems. For the purpose of this research, the treatment consisted of a UASB reactor using two values of hydraulic retention time (HRT) - 8 hours (phase 1) and 12 hours (phase 2) - followed by an activated sludge system. The project was staged in a pilot wastewater treatment plant coupled to USP Sao Carlos\' wastewater treatment system. Pour plate technique was used for analysis of E.coli and total coliforms. IMS was used to detect cysts and oocysts of Giardia spp. and Cryptosporidium spp. DFA (direct immunofluorescence assay) method was chosen to detection and quantification. HRT variation for removal in UASB reactor indicated influence in removal of physical and chemical parameters and in retention of microorganisms. The 12 hours use of HRT obtained removals of 0.21 log for Giardia cysts and 0.48 log for Cryptosporidium oocysts. Activated sludge removals presented 0.48 log and 0.15 log respectively, without significative influence in retention with the HRT\'s change in UASB reactor. High values of contamination were observed during solid-phase analysis in activated sludge, both for Giardia and Cryptosporidium. Here, viability of the (oo)cysts detected was around 30% up to 99% of the analyzed samples.
67

Desenvolvimento de sistemas de controle ótimo para a operação de processos aeróbios de tratamento de esgotos / Development of optimal control system for the operation of aerobic wastewater treatment processes

José Antonio Tosta dos Reis 17 January 2003 (has links)
Neste trabalho, a partir da aplicação da teoria de controle ótimo, são estabelecidos sistemas de controle aplicáveis a três importantes sistemas aeróbios de tratamento de esgotos - filtros biológicos, processos de lodos ativados e os processos combinados formados a partir da combinação dos filtros biológicos e lodos ativados. Para a definição dos sistemas de controle são necessários modelos dinâmicos que descrevam o comportamento dos diferentes sistemas de tratamento. Da literatura são obtidos os modelos dinâmicos destinados à descrição do comportamento do processo de lodos ativados; para o filtro biológico, é proposto um modelo combinando à equação de balanço do reator e o modelo de ordem variável, este último destinado ao cálculo do fluxo de substrato para o interior de biofilmes profundos. Os resultados demonstram que, independentemente do sistema de tratamento considerado, os sistemas de controle reduzem substancialmente os tempos de acomodação e os desvios apresentados pelas variáveis de estado em relação as suas condições de equilíbrio. Por fim, função da inviabilidade de monitoramento de todas as variáveis de estado utilizadas para caracterizar os sistemas de tratamento, são propostos, a partir de modelos simplificados, controladores que incorporam a observação de estados. Também neste caso, os controladores estabelecidos permitem melhorar significativamente o desempenho dos sistemas de tratamento de esgotos analisados. / This paper constructs automatic control systems by means of optimal control theory for three different combinations of wastewater treatment units, namely, trickling filter, activated sludge process and a combined process. The dynamic model for the activated sludge process available in literature and a model proposed for the trickling filter were used in the construction of control systems. It is shown that the controls obtained in this study substantially reduce the durations necessary for the reestablishment of the equilibrium conditions in terms of state variables and the attenuation of oscillations around these conditions. Controls including observers for the state variables were devised on the basis of simplified models for the process in order to deal with the difficulties involved in monitoring all the state variables. These control systems were also found to be quite effective in improving the performance of the wastewater treatment plants considered in this paper.
68

Avaliação da remoção de Giardia spp. e Cryptosporidium spp. em processos de tratamento de esgoto sanitário / Assessment of removal of Giardia spp. and Cryptosporidium spp. from wastewater treatment processes

Medeiros, Raphael Corrêa 27 September 2013 (has links)
Este trabalho teve o intuito de avaliar a eficiência de remoção de protozoários patogênicos - Giardia spp. e Cryptosporidium spp. - em processos de tratamento de esgoto sanitário por reator UASB, lodos ativados, filtro lento em areia e diferentes desinfetantes. A recuperação de cistos de Giardia e de oocistos de Cryptosporidium, realizada por diferentes metodologias e utilizando ColorSeed®, foi de, respectivamente, 85 e 20% em esgoto bruto, e 62,5 e 17,5% em efluente tratado, quando foi utilizado o método de tripla centrifugação. Cistos de Giardia foram encontrados em 100% as amostras de esgoto pesquisadas, com média de 1,5 x 104 cistos por litro e oocistos de Cryptosporidium em 31,4% com média 3,1 x 10² oocistos por litro, em esgoto bruto. No tratamento biológico por reator UASB seguido de Lodos Ativados, a remoção de cisto de Giardia e esporos de Clostridium perfringens foram estatisticamente menores que as remoções de E. coli e coliformes totais. Não foram encontrados (oo)cistos após o tratamento terciário realizado através da filtração lenta em areia. Houve remoção estatisticamente maior na ETE em escala plena para coliformes totais e Clostridium perfringens. E. coli e cistos de Giardia, em ambas ETEs, apresentaram remoções similares. Elevadas concentrações de (oo)cistos foram encontradas no lodo de esgoto, com grande porcentagem ainda viável. Com relação à desinfecção, entre as bactérias indicadoras, Clostridium perfringens foram mais resistentes ao cloro, ozônio e radiação ultravioleta. O efeito sinérgico, promovido pelas desinfecções sequenciais (clororadiação ultravioleta e ozônio-radiação ultravioleta), foi evidenciado em alguns experimentos para todas as bactérias estudadas. O cloro alterou a fluorescência dos cistos de Giardia e o ozônio, além de alterar a fluorescência, foi capaz de diminuir a concentração de cistos desse microrganismo. Pode-se concluir que as concentrações tanto de microrganismos indicadores como de protozoários patogênicos é bastante elevada, qualquer que seja o tipo de esgoto: bruto, efluente do reator UASB ou efluente do lodos ativados. Isso evidencia o extremo cuidado com que estes efluentes devem ser tratados, para posteriores usos ou lançamento em corpo receptor, em especial devido à presença de (oo)cistos ainda viáveis de Giardia spp. e Cryptosporidium spp. mesmo após o tratamento biológico por lodos ativados, e a necessidade de desinfecção do efluente. / This work aimed to evaluate the efficiency of removal of pathogenic protozoa - Giardia spp. and Cryptosporidium spp. - during wastewater treatment by UASB reactor, activated sludge, slow sand filter and different disinfectants. The recovery of Giardia cysts and of Cryptosporidium oocysts, performed by different methodologies and using ColorSeed®, was respectively of 85 and 20%, in raw wastewater and 62.5 and 17.5% in treated effluent, applying triple centrifugation method. Giardia cysts were found in 100% of the the sewage samples surveyed, with average of 1.5 x 104 cysts per liter and Cryptosporidium oocysts were found in 31.4% with average of 3.1 x 10² oocysts per liter, in raw wastewater. Giardia cyst and Clostridium perfringens spores removals were statistically lower than E. coli and total coliforms removal when applying the biological treatment by UASB reactor followed by Activated Sludge. There were no (oo) cysts after treatment tertiary accomplished by slow sand filtration. There was a statistically higher removal in the full scale WWTP for total coliforms and Clostridium perfringens; however, E. coli and Giardia cysts, in both WWTPs, presented the same removal efficiency. High concentrations of (oo)cysts were found in the sludge sludge, with a high percentage still viable. Regarding disinfection, among the indicating bacteria, Clostridium perfringens was more resistant to chlorine, ozone and ultraviolet radiation. The synergic effect promoted by sequential disinfections (chlorine-ultraviolet radiation and ozone-ultraviolet radiation) was evidenced in some experiments for all the bacteria studied. Chlorine altered the fluorescence of Giardia cysts and ozone, as well as change in fluorescence was able to decrease the concentration of this microorganism. It can be concluded that the concentrations of indicator microorganisms as well as of pathogenic protozoa is very high, regardless the kind of wastewater: raw, UASB reactor effluent or activated sludge effluent. This shows the extreme care that must be taken towards these effluents, for future reuse or simply release in the environment, mainly due to the presence of viable Giardia spp. and Cryptosporidium spp. (oo)cysts even after the activated sludge treatment, and the need of disinfection of the effluent.
69

Avaliação da remoção de Giardia spp. e Cryptosporidium spp. em processos de tratamento de esgoto sanitário / Assessment of removal of Giardia spp. and Cryptosporidium spp. from wastewater treatment processes

Raphael Corrêa Medeiros 27 September 2013 (has links)
Este trabalho teve o intuito de avaliar a eficiência de remoção de protozoários patogênicos - Giardia spp. e Cryptosporidium spp. - em processos de tratamento de esgoto sanitário por reator UASB, lodos ativados, filtro lento em areia e diferentes desinfetantes. A recuperação de cistos de Giardia e de oocistos de Cryptosporidium, realizada por diferentes metodologias e utilizando ColorSeed®, foi de, respectivamente, 85 e 20% em esgoto bruto, e 62,5 e 17,5% em efluente tratado, quando foi utilizado o método de tripla centrifugação. Cistos de Giardia foram encontrados em 100% as amostras de esgoto pesquisadas, com média de 1,5 x 104 cistos por litro e oocistos de Cryptosporidium em 31,4% com média 3,1 x 10² oocistos por litro, em esgoto bruto. No tratamento biológico por reator UASB seguido de Lodos Ativados, a remoção de cisto de Giardia e esporos de Clostridium perfringens foram estatisticamente menores que as remoções de E. coli e coliformes totais. Não foram encontrados (oo)cistos após o tratamento terciário realizado através da filtração lenta em areia. Houve remoção estatisticamente maior na ETE em escala plena para coliformes totais e Clostridium perfringens. E. coli e cistos de Giardia, em ambas ETEs, apresentaram remoções similares. Elevadas concentrações de (oo)cistos foram encontradas no lodo de esgoto, com grande porcentagem ainda viável. Com relação à desinfecção, entre as bactérias indicadoras, Clostridium perfringens foram mais resistentes ao cloro, ozônio e radiação ultravioleta. O efeito sinérgico, promovido pelas desinfecções sequenciais (clororadiação ultravioleta e ozônio-radiação ultravioleta), foi evidenciado em alguns experimentos para todas as bactérias estudadas. O cloro alterou a fluorescência dos cistos de Giardia e o ozônio, além de alterar a fluorescência, foi capaz de diminuir a concentração de cistos desse microrganismo. Pode-se concluir que as concentrações tanto de microrganismos indicadores como de protozoários patogênicos é bastante elevada, qualquer que seja o tipo de esgoto: bruto, efluente do reator UASB ou efluente do lodos ativados. Isso evidencia o extremo cuidado com que estes efluentes devem ser tratados, para posteriores usos ou lançamento em corpo receptor, em especial devido à presença de (oo)cistos ainda viáveis de Giardia spp. e Cryptosporidium spp. mesmo após o tratamento biológico por lodos ativados, e a necessidade de desinfecção do efluente. / This work aimed to evaluate the efficiency of removal of pathogenic protozoa - Giardia spp. and Cryptosporidium spp. - during wastewater treatment by UASB reactor, activated sludge, slow sand filter and different disinfectants. The recovery of Giardia cysts and of Cryptosporidium oocysts, performed by different methodologies and using ColorSeed®, was respectively of 85 and 20%, in raw wastewater and 62.5 and 17.5% in treated effluent, applying triple centrifugation method. Giardia cysts were found in 100% of the the sewage samples surveyed, with average of 1.5 x 104 cysts per liter and Cryptosporidium oocysts were found in 31.4% with average of 3.1 x 10² oocysts per liter, in raw wastewater. Giardia cyst and Clostridium perfringens spores removals were statistically lower than E. coli and total coliforms removal when applying the biological treatment by UASB reactor followed by Activated Sludge. There were no (oo) cysts after treatment tertiary accomplished by slow sand filtration. There was a statistically higher removal in the full scale WWTP for total coliforms and Clostridium perfringens; however, E. coli and Giardia cysts, in both WWTPs, presented the same removal efficiency. High concentrations of (oo)cysts were found in the sludge sludge, with a high percentage still viable. Regarding disinfection, among the indicating bacteria, Clostridium perfringens was more resistant to chlorine, ozone and ultraviolet radiation. The synergic effect promoted by sequential disinfections (chlorine-ultraviolet radiation and ozone-ultraviolet radiation) was evidenced in some experiments for all the bacteria studied. Chlorine altered the fluorescence of Giardia cysts and ozone, as well as change in fluorescence was able to decrease the concentration of this microorganism. It can be concluded that the concentrations of indicator microorganisms as well as of pathogenic protozoa is very high, regardless the kind of wastewater: raw, UASB reactor effluent or activated sludge effluent. This shows the extreme care that must be taken towards these effluents, for future reuse or simply release in the environment, mainly due to the presence of viable Giardia spp. and Cryptosporidium spp. (oo)cysts even after the activated sludge treatment, and the need of disinfection of the effluent.
70

Tratamento consorciado de esgoto sanitário com lixiviados de aterros sanitários, lodo de tanques sépticos e efluentes de sanitários químicos por lodos ativados em batelada na ETE Canoas - CORSAN

Souza, Ândrea Aline Rosa de 31 March 2011 (has links)
Submitted by Mariana Dornelles Vargas (marianadv) on 2015-05-12T12:29:45Z No. of bitstreams: 1 tratamento_consorciado.pdf: 6140063 bytes, checksum: 2e4f0cc893d0de295c3aa7272060c547 (MD5) / Made available in DSpace on 2015-05-12T12:29:45Z (GMT). No. of bitstreams: 1 tratamento_consorciado.pdf: 6140063 bytes, checksum: 2e4f0cc893d0de295c3aa7272060c547 (MD5) Previous issue date: 2011-03-31 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / No Brasil, apenas uma pequena parcela do esgoto sanitário coletado é efetivamente tratado. Entretanto, no âmbito urbano há a geração de outros tipos de efluentes tais como lodos de tanques sépticos, neste caso considerado um efluente devido ao teor de água superior a 90%, efluentes de sanitários químicos e lixiviados de aterro sanitários, todos gerados a partir de atividades urbanas, e que necessitam de tratamento adequado para disposição final. O tratamento consorciado destes efluentes externos com esgoto sanitário tem sido utilizado como estratégia para diminuir os custos no tratamento. No entanto, devido a grande variabilidade de composição e concentração, estes efluentes têm difícil tratabilidade, principalmente em estações convencionais. Ainda não há consenso sobre os impactos provocados por esta mistura de efluentes sobre os processos de tratamento encontrados nas ETE's, nem sobre a proporção segura para a diluição a ser adotada em relação ao esgoto sanitário. A ETE Canoas - CORSAN possui um sistema de lodos ativados operando em batelada, tratando de forma consorciada esgotos sanitários, lixiviados de aterros sanitários, lodos de tanques sépticos e efluentes de sanitários químicos, sem uma quantidade máxima estipulada para o recebimento destes efluentes externos. Nesta pesquisa buscou-se caracterizar a mistura afluente e avaliar o impacto do tratamento combinado sobre as condições operacionais da ETE, bem como o seu desempenho na remoção de matéria orgânica e nutrientes, no período de janeiro de 2009 a agosto de 2010. Verificou-se que o percentual de diluição dos efluentes externos no ES variou entre 2,1% e 11,3% e que a contribuição destes efluentes para a carga total da DQO variou entre 14% e 74%. A composição físico-química da mistura afluente ao reator biológico influenciou na composição da microbiota presente no RSB. O impacto mais freqüentemente observado pela entrada de cargas de choque foi a perda de biomassa, devido a problemas de floculação e sedimentação, como o bulking. A ocorrência de cargas de choque decorrentes da entrada de efluentes externos promoveu um aumento do IVL de 46 mL/g para 287 mL/g, da mesma forma verificou-se um aumento da relação A/M, que passou de 0,42 d-¹ para 0,82 d-¹. Entre os metais pesquisados o Ca, Fe e K foram encontrados em maiores percentuais nas amostras de efluentes externos, correspondendo a 15,8%, 10,4% e 10,1%, respectivamente. Também foram detectados teores de Cu, Zn, Ti, Cr, em menores percentuais. No lodo biológico foram detectados 56% de Fe, 16% de Ca, 10% de Si e 8% de S, adsorvidos nos flocos, além Zn (4%), Cu (3%), Mn (1,5%) e K (1,2%). A exposição freqüente da microbiota a cargas de choque foi o principal efeito a colaborar no decréscimo das eficiências de remoção de SST, DBO5, DQO, Ptotal e N-NH4 +, prejudicando a qualidade do efluente final. A adoção de uma unidade de recebimento e tratamento preliminar dos efluentes externos permitirá um maior controle operacional na dinâmica de recebimento e tratamento dos efluentes externos, melhorando o desempenho da ETE. / In Brazil, only a small portion of domestic wastewater collected is effectively treated. In most cities, the treatment system used is the septage, which have low efficiency and need for maintenance and periodic removal of sludge, which must be properly disposed. In the cities there is the generation of other types of waste such as sludge from septage, in this case considered an effluent as the water content exceeds 90%, effluent from chemical toilet and sanitary landfill leachate, all generated from urban activities, and require adequate treatment to final disposal. The combined treatment of these external effluents with domestic wastewater has been used as a strategy to reduce the cost of tractability. However, the great variability of composition and concentration of this effluents, make it a difficult treatability mixture, especially on conventional plants. There is still no consensus on the impacts caused by this mixture of effluents on the degradation processes commonly found in DWTPs nor on the safe ratio for the dilution to be adopted in regard to domestic wastewater. DWTP Canoas - CORSAN has an activated sludge system operating in batch, there is the combined treatment of domestic wastewater, sludge from septage, effluent from chemical toilet and sanitary landfill leachate, without a maximum amount stipulated for receipt of these external effluent. This study aimed to characterize the influent mixture and assess the impact of combined treatment on the operating conditions of the DWTP, as well as its performance in the removal of organics and nutrients between January 2009 to August 2010. It was found that the percentage of dilution of external effluent in domestic wastewater varied between 2.1% and 11.3% and that the contribution of this effluents to the total COD load varied between 14% and 74%. The physico-chemical composition of the influent mixture to biological reactor has influence on the composition of the microfauna present in the SBR. The most frequently observed impact by the shock loads entry was the loss of biomass due to flocculation and settling problems, such as bulking. The occurrence of shock loads due to the entry of external effluents promoted an increase in the SVL of 46 mL/g to 287 mL/g, just as there was an increase in the F/M, which increased from 0.42 d-¹ to 0.82 d-¹. Among the metals analyzed for Ca, Fe and K were found in higher percentages in the external effluent samples, corresponding to 15.8%, 10.4% and 10.1% respectively. Were also detected for Cu, Zn, Ti, Cr, in low percentages. In biological sludge were detected 56% Fe, 16% Ca, 10% Si and 8% of S, adsorbed on the flocs, and Zn (4%), Cu (3%), Mn (1.5%) and K (1.2%). The frequent exposure of activated slugde community to shock loads was the main effect to collaborate in the removal efficiencies reduction of TSS, BOD5, COD, TP and N-NH4 +, damaging the quality of the final effluent. The adoption of a unit for receiving and preliminary treatment of external effluents could permit a greater operational control in the receiving and treatment dynamic of external effluents, improving the performance of DWTP.

Page generated in 0.2451 seconds