Uma metodologia para otimização de sistemas elétricos de distribuição A N condutores / A methodology for optimization of N conductors electrical distribution systemsVieira, Felipe de Alcântara 28 August 2013 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-04-06T19:22:41Z
No. of bitstreams: 1
felipedealcantaravieira.pdf: 1984655 bytes, checksum: e8afc46ad440a574f9f1764bed5e412a (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-04-24T03:52:44Z (GMT) No. of bitstreams: 1
felipedealcantaravieira.pdf: 1984655 bytes, checksum: e8afc46ad440a574f9f1764bed5e412a (MD5) / Made available in DSpace on 2016-04-24T03:52:44Z (GMT). No. of bitstreams: 1
felipedealcantaravieira.pdf: 1984655 bytes, checksum: e8afc46ad440a574f9f1764bed5e412a (MD5)
Previous issue date: 2013-08-28 / Este trabalho propõe uma metodologia com foco na resolução de problemas de
otimização de sistemas elétricos de potência, que por ser extremamente genérica e
abrangente, permite a inserção de qualquer tipo de equipamento na modelagem do
sistema sob estudo, bem como a análise de desequilíbrios, da geração distribuída e de
cabos neutros e aterramentos, em sistemas com N condutores. A metodologia
desenvolvida utiliza como base o Método dos Pontos Interiores Primal-Dual aplicado ao
Método de Injeção de Correntes para a análise do sistema elétrico considerando
equações de injeções de correntes em cada nó, escritas por meio de variáveis complexas
em sua forma retangular. A amplitude de utilização do método proposto o faz
interessante inclusive para estudos de smart grids, uma vez que possibilita um grau de
detalhamento bastante elevado nas representações e análises dos sistemas de
distribuição. / This work proposes a methodology focusing on the solution of electrical power
systems problems, which for being extremely generical and embracing, allows the
inclusion of any type of equipment, in the modeling of the system under study, as well
as the analysis of imbalances, distributed generation and of neutral cables and
groundings on N conductors systems. The methodology developed is based on the
Primal-Dual Interior Point Method applied in the Current Injection Method for the
analysis of the electrical system considering the current injections equations at each
node, written using complex variables in rectangular formulation. The proposed method
has a range of use that make it interesting even for smart grids studies, since it allows a
higher degree of details in the representation and analysis of distribution systems.
|
22 |
FDIPA - algoritmo de pontos interiores e direções viáveis para otimização não-linear diferenciável: um estudo de parâmetrosFonseca, Erasmo Tales 06 November 2015 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-04-28T17:57:49Z
No. of bitstreams: 1
erasmotalesfonseca.pdf: 866120 bytes, checksum: 042a0c3210df8046171b1593162cde44 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-05-02T01:13:24Z (GMT) No. of bitstreams: 1
erasmotalesfonseca.pdf: 866120 bytes, checksum: 042a0c3210df8046171b1593162cde44 (MD5) / Made available in DSpace on 2016-05-02T01:13:24Z (GMT). No. of bitstreams: 1
erasmotalesfonseca.pdf: 866120 bytes, checksum: 042a0c3210df8046171b1593162cde44 (MD5)
Previous issue date: 2015-11-06 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Neste trabalho apresentamos um estudo da influência dos parâmetros de um algoritmo de
pontos interiores e direções viáveis para solução de problemas de otimização não linear.
Esse algoritmo, denominado FDIPA, tem por objetivo encontrar dentre os pontos de um
conjunto definido por restrições de igualdade e/ou desigualdade, aqueles que minimizam
uma função diferenciável. O FDIPA baseia-se na resolução de dois sistemas de equações
lineares com a mesma matriz de coeficientes, obtidos das condições necessárias de primeira
ordem de Karush-Kuhn-Tucker. A partir de um ponto inicial no interior do conjunto
viável, o FDIPA gera uma sequência de pontos também interiores ao conjunto. Em cada
iteração, uma nova direção de descida é obtida e, em seguida, produz-se uma deflexão da
direção de descida no sentido do interior do conjunto viável, de modo a se obter uma nova
direção que seja de descida e viável. Realiza-se então uma busca linear para obter um novo
ponto interior e garantir a convergência global do método. Uma família de algoritmos
pode ser obtida variando-se as regras de atualização dos parâmetros do FDIPA. O estudo
apresentado neste trabalho foi feito considerando-se um único algoritmo e com restrições
de desigualdade somente. Testes numéricos apontaram para uma escolha de parâmetros
que levou a um número menor de iterações na resolução dos problemas teste. / This work presents a study on the influence of the parameters of an interior point and
feasible directions algorithm for solving non-linear problems. The algorithm, named
FDIPA, aims to find among the points of a set defined by equality and/or inequality
constraints, those which minimize a differentiable function. The FDIPA is based on two
linear systems with the same coefficient matrix, obtained from the Karush-Kuhn-Tucker
first order necessary conditions. From a initial point in the interior of the feasible set,
FDIPA generates a sequence of points which are also interior to the set. At each iteration,
FDIPA produces a descent direction which is deflected towards the interior of the feasible
set in order to create a new descent and feasible direction. Then, a linear search is
performed to get a new interior point and assure the global convergence of the method.
A family of algorithms can be obtained varying the rules used to update the parameters
of the FDIPA. The study presented here has been done considering just one particular
algorithm and inequality constraints only. Numerical tests pointed to a certain choice of
parameters which led to a fewer number of iterations when solving some test problems.
|
23 |
Inclusão de restrições dinâmicas na análise de fluxo de potência ótimo / Inclusion of dynamic restrictions in the analysis of optimal power flowFontoura, Rafael Montes 14 August 2006 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-02-14T10:05:06Z
No. of bitstreams: 1
rafaelmontesfontoura.pdf: 1181632 bytes, checksum: b1fad4f811abb57f040a07696d069ebb (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-02-20T17:52:42Z (GMT) No. of bitstreams: 1
rafaelmontesfontoura.pdf: 1181632 bytes, checksum: b1fad4f811abb57f040a07696d069ebb (MD5) / Made available in DSpace on 2017-02-20T17:52:42Z (GMT). No. of bitstreams: 1
rafaelmontesfontoura.pdf: 1181632 bytes, checksum: b1fad4f811abb57f040a07696d069ebb (MD5)
Previous issue date: 2006-08-14 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Este trabalho propõe a inclusão de restrições dinâmicas na análise de Fluxo de Potência Ótimo (FPO), envolvendo o problema associado ao fechamento de anel elétrico e ao planejamento de fontes de potência reativa. Os algoritmos desenvolvidos utilizam a metodologia primal-dual de pontos interiores (MPI) associada à técnica de decomposição matemática de Benders. A utilização do MPI para cálculo do fluxo de potência é motivada pelo seu bom desempenho, possibilidade de se modelar as não linearidades pertinentes aos sistemas elétricos de potência e conceituada utilização em softwares de uso comercial. A técnica de decomposição matemática de Benders é usada para reduzir a dimensão do sistema e proporcionar informações através dos índices de sensibilidade obtidos nos subproblemas. O objetivo da inclusão de restrições dinâmicas no problema de fluxo de potência ótimo é resguardar a integridade de geradores síncronos diante às perturbações presentes no sistema, sejam elas programadas (Fechamento de Anéis) ou não (Contingências). As análises com restrições dinâmicas podem ser uma ferramenta eficiente para definir ações operacionais preventivas ou investimentos no sistema. Para simulações dinâmicas foi utilizado o programa Anatem, desenvolvido Centro de Pesquisa de Energia Elétrica (CEPEL). A metodologia proposta foi implementada em código MATLAB e testada em sistemas IEEE. / This work proposes the inclusion of dynamic constraints in the Optimal Power Flow (OPF) formulation, involving the problem associated with closing loops and reactive power sources planning. The proposed algorithm uses the primal-dual Interior Point Methodology (IPM) associated with the mathematical Benders decomposition technique. The use of IPM was motivated by its performance, possibility to model the nonlinear issues in power systems and its application in commercial software. The mathematical technique of Benders decomposition was used to reduce system dimension and to provide subproblems sensitivity indexes. Dynamic constraints were included in the problem of optimal power flow in such a way to protect the integrity of synchronous generators when system disturbances occur. These disturbances can either be programmed (closing loops) or not (contingencies). The analysis of dynamic impacts can be an efficient tool to define preventive operational actions or to determine the power system investment planning. The dynamic simulations were carried out using the software ANATEM, from CEPEL. The proposed methodology was implemented in MATLAB and tested in IEEE systems.
|
24 |
Resolução do problema de fluxo de potência ótimo reativo via método da função lagrangiana barreira modificada / Resolution of reactive optimal power flow problem via method of Lagrangian modified barrier functionSousa, Vanusa Alves de 08 June 2006 (has links)
Este trabalho propõe uma abordagem que utiliza uma associação dos métodos de barreira modificada e de pontos interiores primal-dual para a resolução do problema de fluxo de potência ótimo (FPO) reativo. Para isso, foi realizado um levantamento bibliográfico que explicitou os conceitos de otimização aplicados ao sistema estático de energia elétrica e os métodos dual-Lagrangiano, Newton-Lagrangiano, primal-dual barreira logarítmica e de barreira modificada. Na abordagem proposta, as restrições canalizadas são desmembradas em duas desigualdades. Estas são transformadas em igualdades a partir do acréscimo de variáveis de folga ou de excesso, as quais são relaxadas e tratadas pela função barreira modificada. Associa-se a esse problema uma função Lagrangiana. O sistema de equações resultantes das condições de estacionaridade da função Lagrangiana foi resolvido pelo método de Newton. Na implementação computacional foram usadas técnicas de esparsidade. Os sistemas elétricos de potência utilizados para verificar a eficiência da abordagem proposta na solução do problema de FPO reativo em três tipos de testes foram o de 3 barras, os do IEEE 14, 30, 118, 162 e 300 barras, o equivalente CESP 440 kV com 53 barras e o equivalente brasileiro sul-sudeste com 787 barras / This work proposes an approach that uses an association of the methods of modified barrier and primal-dual interior points for the resolution of the reactive optimal power flow (OPF) problem. On this purpose, a bibliographical review was accomplished, which enlightened the optimization concepts applied to the static system of electrical energy and the methods dual-Lagrangian, Newton-Lagrangian, primal-dual logarithmic barrier and modified barrier. In this approach, the bounded constraints are transformed in equalities by adding the non-negative slack variables. Those slack variables are relaxed and handled by the modified barrier function. A Lagrangian function is associated to this problem. The equation sets generated by the first-order necessary conditions of the Lagrangian function, were solved by Newton's method. In the computational implementation, sparsity techniques were used. The electric systems used to verify the efficiency of the approach proposed in the solution of the reative OPF problem in three types of tests were of the 3, IEEE 14, 30, 118, 162 and 300 buses, equivalent CESP 440 kV with 53 buses and the equivalent brazilian south-southeast with 787 buses
|
25 |
Estudo e análise do desempenho do método barreira modificada / Study and analysis of performance of modified barrier methodCristiane Regina Mariano 04 December 2006 (has links)
Este trabalho tem por objetivo estudar e analisar a influência do parâmetro de barreira e de seu fator de correção no processo de convergência dos métodos de pontos interiores primal-dual, primal-dual barreira modificada e primal-dual barreira modificada com as técnicas preditor-corretor e Newton composto. A grande motivação para o desenvolvimento desta pesquisa está relacionada com a busca de métodos eficientes para resolver problemas de otimização de programação não-linear, existentes na área de engenharia elétrica mais especificamente na operação de sistemas elétricos de potência. Esses métodos foram aplicados a um problema de programação não-linear e aos sistemas elétricos de três e de trinta barras para analisar a sensibilidade em relação ao parâmetro de barreira e ao seu fator de correção. / This work has for objective to study and to analyze the influence of the barrier parameter and its correction factor in the convergence process of the methods primal-dual interior point, primal-dual modified barrier and primal-dual barrier modified with the techniques predictor-corrector and composed Newton. The great motivation for the development of this research is related with the search of efficient methods to solve nonlinear programming optimization problems, existent in the area of electric engineering more specifically in the operation of power systems. Those methods were applied to a nonlinear programming problem and the electric systems of three and thirty buses to analyze the sensibility in relation to the barrier parameter and its correction factor.
|
26 |
Estudo e análise do desempenho do método barreira modificada / Study and analysis of performance of modified barrier methodMariano, Cristiane Regina 04 December 2006 (has links)
Este trabalho tem por objetivo estudar e analisar a influência do parâmetro de barreira e de seu fator de correção no processo de convergência dos métodos de pontos interiores primal-dual, primal-dual barreira modificada e primal-dual barreira modificada com as técnicas preditor-corretor e Newton composto. A grande motivação para o desenvolvimento desta pesquisa está relacionada com a busca de métodos eficientes para resolver problemas de otimização de programação não-linear, existentes na área de engenharia elétrica mais especificamente na operação de sistemas elétricos de potência. Esses métodos foram aplicados a um problema de programação não-linear e aos sistemas elétricos de três e de trinta barras para analisar a sensibilidade em relação ao parâmetro de barreira e ao seu fator de correção. / This work has for objective to study and to analyze the influence of the barrier parameter and its correction factor in the convergence process of the methods primal-dual interior point, primal-dual modified barrier and primal-dual barrier modified with the techniques predictor-corrector and composed Newton. The great motivation for the development of this research is related with the search of efficient methods to solve nonlinear programming optimization problems, existent in the area of electric engineering more specifically in the operation of power systems. Those methods were applied to a nonlinear programming problem and the electric systems of three and thirty buses to analyze the sensibility in relation to the barrier parameter and its correction factor.
|
27 |
Resolução do problema de fluxo de potência ótimo reativo via método da função lagrangiana barreira modificada / Resolution of reactive optimal power flow problem via method of Lagrangian modified barrier functionVanusa Alves de Sousa 08 June 2006 (has links)
Este trabalho propõe uma abordagem que utiliza uma associação dos métodos de barreira modificada e de pontos interiores primal-dual para a resolução do problema de fluxo de potência ótimo (FPO) reativo. Para isso, foi realizado um levantamento bibliográfico que explicitou os conceitos de otimização aplicados ao sistema estático de energia elétrica e os métodos dual-Lagrangiano, Newton-Lagrangiano, primal-dual barreira logarítmica e de barreira modificada. Na abordagem proposta, as restrições canalizadas são desmembradas em duas desigualdades. Estas são transformadas em igualdades a partir do acréscimo de variáveis de folga ou de excesso, as quais são relaxadas e tratadas pela função barreira modificada. Associa-se a esse problema uma função Lagrangiana. O sistema de equações resultantes das condições de estacionaridade da função Lagrangiana foi resolvido pelo método de Newton. Na implementação computacional foram usadas técnicas de esparsidade. Os sistemas elétricos de potência utilizados para verificar a eficiência da abordagem proposta na solução do problema de FPO reativo em três tipos de testes foram o de 3 barras, os do IEEE 14, 30, 118, 162 e 300 barras, o equivalente CESP 440 kV com 53 barras e o equivalente brasileiro sul-sudeste com 787 barras / This work proposes an approach that uses an association of the methods of modified barrier and primal-dual interior points for the resolution of the reactive optimal power flow (OPF) problem. On this purpose, a bibliographical review was accomplished, which enlightened the optimization concepts applied to the static system of electrical energy and the methods dual-Lagrangian, Newton-Lagrangian, primal-dual logarithmic barrier and modified barrier. In this approach, the bounded constraints are transformed in equalities by adding the non-negative slack variables. Those slack variables are relaxed and handled by the modified barrier function. A Lagrangian function is associated to this problem. The equation sets generated by the first-order necessary conditions of the Lagrangian function, were solved by Newton's method. In the computational implementation, sparsity techniques were used. The electric systems used to verify the efficiency of the approach proposed in the solution of the reative OPF problem in three types of tests were of the 3, IEEE 14, 30, 118, 162 and 300 buses, equivalent CESP 440 kV with 53 buses and the equivalent brazilian south-southeast with 787 buses
|
28 |
Uma nova metodologia para estimação de estados em sistemas de distribuição radiais utilizando PMUsAlves, Guilherme de Oliveira 18 September 2015 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-05-16T17:51:25Z
No. of bitstreams: 1
guilhermedeoliveiraalves.pdf: 1293169 bytes, checksum: a76074780b2af177b66be7c6435b16d1 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-06-28T12:25:31Z (GMT) No. of bitstreams: 1
guilhermedeoliveiraalves.pdf: 1293169 bytes, checksum: a76074780b2af177b66be7c6435b16d1 (MD5) / Made available in DSpace on 2016-06-28T12:25:31Z (GMT). No. of bitstreams: 1
guilhermedeoliveiraalves.pdf: 1293169 bytes, checksum: a76074780b2af177b66be7c6435b16d1 (MD5)
Previous issue date: 2015-09-18 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O presente trabalho tem por objetivo apresentar uma nova metodologia para estimação
estática de estados em sistemas de distribuição de energia elétrica que estima as correntes
nos ramos como variáveis de estado utilizando medições de tensão e corrente de ramo
fasoriais oriundas de unidades de medição fasorial (Phasor Measurement Units - PMUs).
A metodologia consiste em resolver um problema de otimização não linear minimizando
uma função objetivo quadrática associada com as medições e estados estimados sujeito
às restrições de carga das barras da rede que não apresentam PMUs instaladas baseadas
em dados históricos, sendo esta a principal contribuição deste trabalho. Uma proposta
de alocação de PMUs também é apresentada e que consiste em alocar duas unidades
em cada ramificação do sistema, uma no começo e outra no final do trecho, procurando
utilizar o menor número possível e que não comprometa a qualidade dos estados estimados.
A resolução do problema de otimização é realizada de duas formas, através da ‘toolbox
fmincon’ do software Matlab, que é uma ferramenta muito utilizada na resolução de
problemas de otimização, e através da implementação computacional do Método de Pontos
Interiores com Barreira de Segurança (Safety Barrier Interior Point Method - SFTB - IPM)
proposto na literatura utilizada. Durante o processo de estimação de estados são utilizadas
medidas obtidas através de um fluxo de potência que simulam as PMUs instaladas nos
sistemas analisados variando o carregamento de cada sistema em torno da sua média
histórica de carga até atingir os limites superior e inferior estabelecidos, sendo verificado
o comportamento do estimador de estados perante a ocorrência de ruídos brancos nas
medidas de todos os sistemas analisados. Foram analisados um sistema de distribuição
tutorial de 15 barras e três sistemas encontrados na literatura contendo 33, 50 e 70 barras
respectivamente. No sistema tutorial e no de 70 barras foram incluídas unidades de
geração distribuída para se verificar o comportamento do estimador de estados. Todos
os resultados do processo de estimação de estados são obtidos com os dois métodos de
resolução apresentados e são comparados o desempenho de cada método, principalmente
em relação ao tempo computacional. Todos os resultados obtidos foram validados usando
um programa de fluxo de potência convencional e apresentam boa precisão com valor de
função objetivo baixo mesmo na presença de ruídos nas medidas refletindo de maneira
confiável o real estado do sistema de distribuição, o que torna a metodologia proposta
atraente. / This work aims at presenting a new methodology for static state estimation in electric
power distribution systems which estimates the branch currents as state variables using
voltage measurements and current phasor branch obtained from phasor measurement
units (Phasor Measurement Units - PMUs). The methodology consists of solving a
nonlinear optimization problem minimizing a quadratic objective function associated with
the estimated measurements and states, subject to load constraints for the non monitored
loads based on historical data, which is the main contribution of this work. A PMU
allocation strategy is presented which consists of allocating two PMUs for each system
branch, one at the beginning and another at the end, trying to use as little PMUs as
possible in such a way that the quality of the estimated states are not compromised. The
solution of the optimization problem is obtained through two ways, the first is the toolbox
‘fmincon’ from Matlab solver software which is a widely used tool in the optimization
problem. The second is a computer implementation of interior point method with security
barrier (SFTB - IPM) proposed in the literature. Comparisons of computing times and
results obtained with both methods are shown. A power flow program is used to obtain the
voltages and branch currents in order to emulate the PMUs data in the state estimation
process. Additionaly the non monitored loads are varied from the minimum bounds to
their maximum, allowing white noise errors from the PMUs measurements. A tutorial
test system of 15 buses is fully explored and three IEEE test systems of 33, 50 and 70
buses are used to show the effectiveness of the proposed methodology. For the tutorial
and 70 bus systems, distribued generation units were included to see the state estimator
behavior. All results from the state estimation process are obtained considering the
two presented solving methods and the computing times performance compared. The
results obtained were validated using a conventional power flow program and have good
accuracy with low objective function value even in the presence of white noise errors in
the measurements reflecting the reliability of the proposed methodology, making it very
attractive for distribution system monitoring.
|
29 |
Estimação de estados em sistemas de distribuição: uma abordadgem trifásica e descentralizadaOliveira, Bráulio César de 08 March 2016 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-01-09T11:36:05Z
No. of bitstreams: 1
brauliocesardeoliveira.pdf: 2150243 bytes, checksum: 62faa254539b7873aa1393d8cd8f1bf2 (MD5) / Approved for entry into archive by Diamantino Mayra (mayra.diamantino@ufjf.edu.br) on 2017-01-31T11:23:24Z (GMT) No. of bitstreams: 1
brauliocesardeoliveira.pdf: 2150243 bytes, checksum: 62faa254539b7873aa1393d8cd8f1bf2 (MD5) / Made available in DSpace on 2017-01-31T11:23:24Z (GMT). No. of bitstreams: 1
brauliocesardeoliveira.pdf: 2150243 bytes, checksum: 62faa254539b7873aa1393d8cd8f1bf2 (MD5)
Previous issue date: 2016-03-08 / O presente trabalho tem por objetivo apresentar uma metodologia para estimação de estados em sistemas de distribuição de energia elétrica. São utilizadas como variáveis de estado as correntes nos ramos. As medições são obtidas por meio de medições fasoriais sincronizadas(PhasorMeasurementUnits-PMUs),sendoqueostiposdemedidasadvindos desses equipamentos são as tensões nodais e as correntes nos ramos. A abordagem é trifásica, portanto representa as características próprias de um sistema de distribuição. A metodologia consiste em resolver um problema de otimização não linear cuja função objetivo associa o erro quadrático das medidas em relação aos estados estimados sujeito às restrições de carga das barras da rede que não possuem PMUs instaladas baseadas em estimativas de cargas obtidas para o instante “t-1”, partindo-se da premissa que em curtos intervalos de tempo a carga não sofre grandes variações, sendo esta em conjunto com a abordagem trifásica as principais contribuições deste trabalho. Outra contribuição do trabalho é a descentralização, com esta técnica pode-se dividir uma determinada rede em vários subsistemas que podem ser resolvidos de forma separada e independente. Isso torna o processo mais rápido do ponto de vista computacional além de permitir o uso do processamento paralelo, visto que já existe um paralelismo natural entre as tarefas que devem ser resolvidas. Outra vantagem da divisão em subsistemas reside no fato do monitoramento de áreas de interesse. Para utilizar a descentralização foi proposta uma alternativa de alocação de PMUs que consiste em posicionar duas unidades em cada ramificação do sistema, uma no começo e outra no final do trecho, procurando utilizar o menor número possível e que não comprometa a qualidade dos estados estimados. A resolução do problema de otimização é realizada através da implementação computacional do Método de Pontos Interiores com Barreira de Segurança (Safety Barrier Interior Point Method - SFTB - IPM) proposto na literatura especializada. As medidas das PMUs foram obtidas através de um Fluxo de Potência Trifásico via Injeção de Correntes (FPTIC). Foram realizadas diversas simulações variando-se o percentual da carga e os resultados obtidos foram comparados com outra metodologia existente na literatura e com os valores verdadeiros que foram obtidos através do FPTIC para as barras não monitoradas. Foram tambémcomparadosotempocomputacionalentreaexecuçãoserialeaexecuçãoutilizando o processamento paralelo. Os testes mostraram bons resultados o que torna a metodologia proposta aplicável na supervisão de sistemas de distribuição. / This work aims to present a methodology for static state estimation in electric power distribution systems. Branch currents are used as state variables. Measurements are obtained by means of Phasor Measurement Units (PMUs), in which voltage and current branches measurements are used. The approach is three-phase, thus represents the distribution system characteristics. The methodology consists of solving a nonlinear optimization problem minimizing a quadratic objective function associated with the estimated measurements and states subject to load constraints for the non monitored loads based on estimated load obtained from the ‘t-1’ instant, starting from the assumption that in short time intervals the load does not have large variations, which together with the the three-phase approach are the main contributions of this work. Another contribution of this work is the descentralided approach, with this assumption the network can be divided into several subnetworks that can be solved separately and independently. This speeds up the process of being solved from a computational point of view and allows the use of parallel processing, since there is already a natural parallelism among tasks to be solved. Another advantage of the division into subsystems is the fact that the monitoring areas of interest. With the aim of allowing the decentralization was proposed PMUs allocation strategy that consists of allocating two units for each lateral feeder, one at the beginning and one at the end, trying to use as little PMUs as possible in such a way that the quality of the estimated states are not compromised. The resolution of the optimization problem is done through a computer implementation of Interior Point Method with Security Barrier (SFTB - IPM) proposed in the literature. The PMUs measurements were emulated using a Three-PhasePowerFlowusingtheCurrentInjectionmethod(FPTIC).Severalsimulations were performed varying the load percentage and the results obtained were compared with other existing methodology in literature and also the true values that were obtained from the FPTIC to non monitored loads. The computational time using serial and parallel processing were also compared. Results show good results which makes the proposed methodology applicable in monitoring distribution systems.
|
30 |
Programação diária da operação de sistemas termelétricos utilizando algoritmo genético adaptativo e método de pontos interioresMenezes, Roberto Felipe Andrade 26 January 2017 (has links)
Fundação de Apoio a Pesquisa e à Inovação Tecnológica do Estado de Sergipe - FAPITEC/SE / The growth of the electric energy consumption in the last years has generated the need of
the increase in the amount of power sources, making the electricity sector undergo some large
changes. This has provided the search for tools that promotes a better efficiency and security to the
electrical power systems. A planning problem that is considered important in the daily operation
of the power systems is the Unit Commitment, where the time schedule of the operation is
defined, determining which machines will be online or offline, and which are the operating points.
Those units must operate by load variation, respecting the operative and security constraints.
This research proposes the resolution of the problem for the short-term planning, taking a set
of constraints associated with the thermal generation and the power system. Among them, we
can highlight the output power variation constraints of the machines and the security restrictions
of the transmission system, avoided in most Unit Commitment studies. This problem is nonlinear,
mixed-integer and has a large scale. The methodology used involves the utilization of an
Adaptive Genetic Algorithm, for the Unit Commitment problem, and the Interior-Point Primal-
Dual Predictor–Corrector Method, for DC power flow resolution in economic dispatch problem.
Furthemore, this research proposes the implementation of cross-over and mutation operators of
Genetic Algorithm based on a ring methodology applied in Unit Commitment matrix. The results
were obtained through simulations in a mathematical simulation software, using the IEEE test
systems with 30 bus and 9 generators, and another with 24 bus and 26 generators. The validation
of the algorithm was done by comparing the results with other works in the literature. / O crescimento do consumo de energia elétrica nos últimos anos vem gerando a necessidade de um
aumento na quantidade de fontes geradoras, fazendo com que o setor elétrico passe por grandes
mudanças. Isso tem proporcionado a busca por ferramentas que ofereçam maior eficiência
e segurança aos sistemas de potência. Um problema considerado de extrema importância na
operação diária dos sistemas elétricos é o planejamento da Alocação das Unidades Geradoras,
onde define-se a programação horária das unidades do sistema, determinando quais máquinas
deverão estar ligadas ou desligadas, e quais serão seus respectivos pontos de operação. Essas
unidades geradoras devem operar de forma eficaz, mediante a variação da carga, respeitando
restrições operativas e de segurança do sistema. Este trabalho propõe a resolução do problema
para o planejamento de curto prazo, levando em consideração uma série de restrições relacionadas
a geração térmica e ao sistema elétrico. Entre elas, podemos destacar as restrições de variação de
potência de saída das máquinas e as restrições de segurança do sistema de transmissão, evitadas
na maioria dos estudos de Alocação de Unidades Geradoras. Este problema tem característica
não-linear, inteiro-misto e de grande escala. A metodologia utilizada para resolução do problema
envolve a utilização de um Algoritmo Genético Adaptativo, para Alocação das Unidades, e
o Método de Pontos Interiores Primal-Dual Preditor-Corretor, para a resolução do Fluxo de
Potência Ótimo DC no problema do Despacho Econômico. Além disso, este trabalho propõe
a implementação dos operadores de cross-over e mutação do Algoritmo Genético com base
em uma metodologia anelar aplicada na matriz de alocação de unidades. Os resultados foram
obtidos através de simulações em um software de simulação matemática, utilizando os sistemas
testes do IEEE de 30 barras com 9 geradores e 24 barras com 26 geradores, e a validação do
algoritmo foi feita comparando os resultados obtidos com os outros trabalhos da literatura.
|