• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Tecnica optica de moire visando a aplicação no estudo de superficies irregulares

Lino, Antonio Carlos Loureiro 03 August 2018 (has links)
Orientador: Inacio Maria Dal Fabbro / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agricola / Made available in DSpace on 2018-08-03T16:34:58Z (GMT). No. of bitstreams: 1 Lino_AntonioCarlosLoureiro_M.pdf: 6146192 bytes, checksum: 34f4cf4a7a53c2b91adc0c5de78ca694 (MD5) Previous issue date: 2002 / Mestrado
2

Desenvolvimento de procedimentos de análise por injeção em fluxo para a determinação de furosemida, paracetamol e acetilcisteína em formulações farmacêuticas. / Development of flow injection analysis procedures to determination of furosemide, paracetamol and acetylcysteine in pharmaceutical formaulation.

Vieira, Heberth Juliano 25 August 2006 (has links)
Made available in DSpace on 2016-06-02T20:34:04Z (GMT). No. of bitstreams: 1 TeseHJV.pdf: 1956534 bytes, checksum: 5b1ec2c1b2bc024b56436faa641fafce (MD5) Previous issue date: 2006-08-25 / Financiadora de Estudos e Projetos / In this thesis are presented the development of flow injection analysis procedures with spectrophotometric detection for determination of furosemide, paracetamol and acetylcysteine in samples of pharmaceutical formulations. A flow injection system was optimized for indirect determination of furosemide monitoring the excess of sodium hypochlorite not consumed in the reaction with the furosemide using o-tolidine as reagent at 430 nm. The analytical curve was linear from 5.0x10-6 to 8.0x10-5 mol L-1 and the detection limit was 2.5x10-6 mol L-1. A RSD smaller than 2.0% (n=10) for 1.0x10-5 and 5.0x10-5 mol L-1 furosemide solutions and an analytical frequency of 60 determinations h-1 were obtained. Another flow injection system was proposed to determine paracetamol in pharmaceutical samples employing sodium hypochlorite and o-tolidine as reagents. In this flow system, sodium hypochlorite reacted with paracetamol and its concentration in excess was monitored with o-tolidine. After system optimization, the analytical curve was linear in the paracetamol concentration range from 8.5x10-6 mol L-1 to 2.5x10-4 mol L-1 with a detection limit of 5.0x10-5 mol L-1. A RSD of 1.2% (n=10) was obtained for 1.5x10-4 mol L-1paracetamol solution. The analytical frequency of the system was 60 determinations h-1. The otolidine and its products used in both proposed flow injection systems were on line destroyed using an ultraviolet lamp (λ=380 nm) and hydrogen peroxide solution. The reversed flow system was proposed for determination of paracetamol employing sodium nitrite as reagent. The product formed was monitored at 400 nm. The analytical curve was linear in the paracetamol concentration range from 4.0x10-5 to 1.1x10-3 mol L-1 with a limit of detection of 2.0x10-5 mol L-1 and analytical frequency of 45 determinations h-1. RSD smaller than 2% were obtained for 8.0x10-4 and 1.0x10-3 paracetamol solutions. A flow system injection procedure with spectrophotometric detection to determine acetylcysteine was developed. In this procedure, acetylcysteine reacts with Ce(IV) solution and the excess of cerium (IV) was monitored with ferroin at 500 nm. An analytical curve ranged from 1.32x10-5 to 1.35x10-4 mol L-1 with a limit of detection of 8.0x10-6 mol L-1 were obtained. A RSD of 1.4% (n=10) for 2.2x10-5 mol L-1 acetylcysteine solution and an analytical frequency of 60 determinations h-1 were obtained. Another flow injection system for determine acetylcysteine using bromine (Br2) as reagent was also proposed. In this system, Br2 chemically generated on line reacts with the analyte and its excess monitored at 400 nm. The analytical curve obtained was linear from 1.6x10-4 and 1.6x10-3 mol L-1 and RSD of 1.2 % (n=10) for 5.3x10-4 solution were obtained. The system showed the analytical frequency of 60 determinations h-1 and ascorbic acid solution was used to destruct bromine on line. / Neste trabalho de tese são apresentados o desenvolvimento de procedimentos de análises por injeção em fluxo com detecção espectrofotométrica para a determinação de furosemida, paracetamol e acetilcisteína em amostras de interesse farmacêutico. Um sistema em fluxo para a determinação indireta de furosemida foi otimizado monitorando-se o excesso de hipoclorito de sódio não consumido em reação com a furosemida utilizando o-tolidina como reagente em 430 nm. A curva analítica apresentou uma linearidade entre 5x10-6 a 8x10-5 mol L-1 e um limite de detecção de 2,5x10-6 mol L-1. Desvios padrão relativos menores que 2,0% (n=10) para soluções de furosemida com concentrações de 1,0x10-5 e 5x10-5 mol L-1 e freqüência de amostragem de 60 determinações h-1 foram obtidos. Outro sistema em fluxo foi proposto para a determinação indireta de paracetamol em formulações farmacêuticas empregando hipoclorito de sódio e o-tolidina como reagentes. Nesse sistema em fluxo o hipoclorito de sódio em excesso foi monitorado com o-tolidina em 430 nm. Após a otimização obteve-se uma curva analítica entre 8,5x10-6 a 2,5x10-4 mol L-1 e um limite de detecção de 5,0x10-5 mol L-1. Desvio padrão relativo para uma solução de paracetamol foi de 1,5x10-4 mol L-1 de 1,2% (n=10) e freqüência de amostragem de 60 determinações h-1 foram obtidos. Nos sistemas em fluxo propostos, os quais empregaram o-tolidina como reagente foi acoplada uma lâmpada ultravioleta (λ=380 nm) após o detector que permitiu a destruição desse reagente empregando conjuntamente uma solução de peróxido de hidrogênio. Um sistema de análise em fluxo reverso foi também proposto para determinação de paracetamol empregando nitrito como reagente. O produto da reação foi monitorado em 430 nm. O sistema em fluxo apresentou uma curva analítica entre 4,0x10-5 a 1,1x10-3 mol L-1. O limite de detecção foi de 2,0x10-5 mol L-1 e a freqüência de amostragem foram 45 determinações por h-1. Desvios padrão relativos menores que 2% foram obtidos para as duas soluções de referência de paracetamol nas concentrações de 8,0x10-4 mol L-1 e 1,0x10-3 mol L-1. Um procedimento analítico para determinação de acetilcisteína, com detecção espectrofotométrica em 500 nm, empregando o Ce(IV) e ferroína como reagentes foi otimizado. Nesse sistema em fluxo obteve-se uma curva analítica entre 1,3x10-5 a 1,3x10-4 mol L-1. O limite de detecção obtido foi de 8,0 x 10-6 mol L-1. Um desvio padrão relativo para uma solução de referência de acetilcisteína 2,2x10-5 mol L-1 foi de 1,4 % (n=10) e uma freqüência de amostragem de 60 determinações por hora foram obtidos. Outro procedimento em fluxo para a determinação de acetilcisteína empregando bromo (Br2) gerado quimicamente foi proposto. Nesse sistema, o bromo produzido quimicamente reage com o analito e seu excesso foi monitorado em 400 nm. A curva analítica foi linear no intervalo de concentração de acetilcisteína de 1,6x10-4 a 1,6 x10-3 mol L-1 e um desvio padrão relativo de 1,2% (n=10) para uma solução de acetilcisteína 5,3x10-4 mol L-1 foi obtido. O sistema apresentou uma freqüência de amostragem de 60 determinações h-1 e uma solução de ácido ascórbico foi empregada para destruição do bromo em linha.
3

Desenvolvimento de estratégias para a determinação espectrofotométrica sequencial em fluxo de Co (II) e Mn (II) / DEVELOPMENT OF FLOW ANALYSIS SPECTROPHOTOMETRIC STRATEGIES FOR SEQUENTIAL DETERMINATION OF Co AND Mn

Ferreira, Juliana Aparecida 24 July 2009 (has links)
Made available in DSpace on 2016-06-02T20:36:18Z (GMT). No. of bitstreams: 1 2542.pdf: 1028251 bytes, checksum: d141897549d1cbb1f8d2fc87cce9ea26 (MD5) Previous issue date: 2009-07-24 / Financiadora de Estudos e Projetos / In this study a kinetic-spectrophotometric method was developed for sequential determination of Co and Mn in pharmaceutical samples. The method was based on the catalytic effect of the analytes in the oxidation reaction of Tiron by H2O2 in basic medium. In the case of Mn it was employed the activator reagent 2,2-bipyridine to effective catalysis. The FIA system was projected taking into account the catalytic properties of each analyte in the indicator reaction. Two factorial designs were applied, initially, a fractionary factorial design 29-5 followed by a complete factorial design 23 to select the important variables, and then a factorial design 22 + central point + star for optimizing of FIA system. Fractionary factorial designs 27-2 were applied in the study of possible interferents for Co and Mn. The main interferents were mathematically described using factorial + central point + star designs. The pharmaceutical samples were digested by concentrated HNO3 in digestor block. To evaluate the accuracy of the developed method, samples (n=3) were analyzed by FS-FAAS and based on the determination concentrations, these were diluted to posterior analysis aplyingby the developed method. Limits of detection (LOD) and quantification (LOQ) for FS-FAAS were 3.9 and 13.2 μg L-1 for Co; 110.0 and 366.0 μg L-1 for Mn, respectively. To developed method the LOD and LOQ were 0.055 and 0.18 μg L-1 for Co, 9.76 and 32.5 μg L-1 for Mn, respectively. Comparison between the two methods was evaluated by paired t-test. At 99% confidence level, the values did not differ statistically for Co. However, for Mn, the concentration values agreed but this data cannot be statistically confirmed due to differences of standard deviations of the two methods. The repeatability was 3.2% for Co and 8.0% for Mn. The sampling frequency was 25 samples h-1. / Neste trabalho desenvolveu-se um método cinético-espectrofotométrico visando a determinação sequencial de Co e Mn em amostras farmacêuticas. O método foi baseado no efeito catalítico dos analitos na reação de oxidação do Tiron (3,5 dihidroxi-1,3-ácido benzenossulfônico-sal dissódico monohidratado [(HO)2C6H2(SO3Na)2.H2O]) pelo H2O2 em meio básico. No caso do Mn foi empregado o reagente ativador 2,2-bipiridina para a efetiva catálise. O sistema FIA foi elaborado com base nas propriedades catalíticas de cada analito na reação indicadora. Foram realizados dois planejamentos fatoriais, inicialmente um fracionário 29-5 e depois um 23, para triagem das variáveis, seguido de um 22 + ponto central + estrela para a devida otimização das mesmas no sistema em fluxo. Planejamentos fatoriais fracionários 27-2 foram realizados para o estudo de possíveis interferentes para Co e Mn; e posteriormente, a porcentagem de interferência foi descrita através de modelos matemáticos construídos a partir de planejamentos do tipo fatorial + ponto central + estrela. As amostras farmacêuticas foram digeridas com HNO3 concentrado em bloco digestor. Para avaliar a exatidão do método desenvolvido, as amostras (n=3) foram analisadas por FS-FAAS e a partir das concentrações obtidas, estas foram diluídas para posterior análise no método desenvolvido. Os limites de detecção e quantificação para FS-FAAS foram 3,9 e 13,2 μg L-1 para Co, 110,0 e 366,0 μg L-1 para Mn, respectivamente. No caso do método desenvolvido, os limites de detecção e quantificação foram 0,055 e 0,18 μg L-1 para Co, 9,76 e 32,5 μg L-1 para Mn, respectivamente. A comparação entre os dois métodos foi realizada através do teste-t pareado. No caso do Co, ao nível de confiança 99% os valores não diferiram estatisticamente. Já para o Mn os valores de concentração obtidos também foram concordantes entre si, apesar deste fato não poder ser comprovado estatisticamente devido à diferença de desvios-padrão dos dois métodos. A repetibilidade foi de 3,2% para Co e 8,0% para Mn. A frequência de amostragem foi de 25 amostras h-1.
4

Desenvolvimento e aplicação de procedimentos envolvendo reações quimiluminescentes em fluxo para a determinação de analitos de interesse alimentício, farmacêutico e bioquímico. / Development and application of procedures envelopemend chemiluminescent reactions in flow for determination of analytes of interest in food, pharmaceutical and biochemistry.

Leite, Oldair Donizeti 23 September 2005 (has links)
Made available in DSpace on 2016-06-02T20:34:03Z (GMT). No. of bitstreams: 1 TeseODL.pdf: 1297245 bytes, checksum: 435cbc8b2b2d81a30ebbfb4ce3797551 (MD5) Previous issue date: 2005-09-23 / Universidade Federal de Minas Gerais / In this work, analytical flow procedures were developed using multicommutation concept and chemiluminescent detection for the determination of hydrogen peroxide, glucose and cholesterol in food, biochemistry and pharmaceutical samples. A personal computer Pentium 233 MHz equipped with PCL 711S interface was employed to control the flow manifold and data acquisition. The detection module consist of a flow-cell constructed with a coiled polyethylene tubing (0.8 mm i.d.), a silicon photodiode (OSD-50E) and an electronic device (model FAC 500) for signals conditioning and amplification, are devices were placed in a dark box. The manifold and detection module were characterized by hydrogen peroxide determination in pharmaceutical samples, monitoring the radiation produced in the chemiluminescent reaction between luminol, H2O2 and hexacyanoferrate(III). The analytical curve obtained was linear in the hydrogen peroxide concentration ranging from 2.2 x 10-6 to 2.1 x 10-4 mol L-4 and the detection limit obtained was 1.8 x 10-6 mol L-1. In the procedures for glucose determination in food, pharmaceutical and biochemical samples, a solid-phase reactor containing glucose oxidase immobilized in glass beads was employed. The hydrogen peroxide generated in this enzymatic reaction was monitored by chemiluminescent emission produced by the luminol/hexacyanoferrate(III) reaction. The proposed procedure showed linear response from 5.0 to 160.0 mg L-1 and a sampling rate of 160 samples per hour was obtained. The analytical procedure was employed with success in the glucose determination in honey, glucose pharmaceutical formulation, grape and tomato juices. For glucose determination in blood serum, the manifold was reconfigured to minimize the sample manipulation. The results obtained in the glucose determination in serum using this proposed procedure are in close agreement with those obtained using the comparative procedure at a confidence level of 95%. In the proposed procedure for cholesterol determination in eggs a solid-phase reactor containing immobilized cholesterol oxidase was used, the hydrogen peroxide produced was monitored by the same chemiluminescent reaction. The linear range of analytical curve obtained in optimized procedure ranged from 250 to 2500 mg L-1, and are described by the equation: Intensity (mV)= 43.0 + 0.325 x [cholesterol], r= 0.999, The luminol and hexacyanoferrate(III) consumption per determination were 356 µg and 2.64 mg, respectively. The manifold was reconfigured for cholesterol determination in serum. The results obtained were in agreement with those obtained using the comparative procedure. Extraction and pre-purification of enzyme peroxidase were carried out with the purpose of employing this enzyme as a catalyst in the chemiluminescent reaction between the luminol and hydrogen peroxide. / No presente trabalho, foram desenvolvidos procedimentos analíticos em fluxo empregando o conceito de multicomutação e detecção por quimiluminescência para a determinação de peróxido de hidrogênio, glicose e colesterol em amostras alimentícias, bioquímicas e farmacêuticas. Para o controle do módulo de análise e a aquisiçãode dados foi empregado um microcomputador Pentium 233 MHz equipado com uma interface eletrônica (PCL-711S), através de programas em linguagem Lab-View 6.0. O módulo de detecção consistiu de uma cela de fluxo de polietileno (em espiral), um fotodiodo de silício (OSD-50E) e um dispositivo eletrônico (modelo FAC 500), para condicionamento e amplificação dos sinais, que foram acondicionados dentro de uma caixa plástica. O módulo de análise e detecção foi caracterizado e empregado inicialmente na determinação de H2O2 em amostras farmacêuticas, monitorando-se a quimiluminesência produzida na reação entre o luminol, H2O2 e hexacianoferrato(III) de potássio. A curva analítica apresentou uma linearidade entre 2,2 x 10-6 a 2,1 x 10-4 mol L-4 e limite de detecção estimado em 1,8 x 10-6 mol L-1. Nos procedimentos para a determinação de glicose em amostras alimentícias, farmacêuticas e bioquímicas, foi acoplado no percurso analítico, um reator enzimático contendo a enzima glicose oxidase imobilizada. O H2O2 gerado na reação enzimática foi monitorado pela quimiluminescência gerada na reação entre o luminol e hexacianoferrato(III) de potássio. Após a otimização do procedimento analítico, obteve-se uma faixa linear de resposta de 5,0 a 160,0 mg L-1 e uma freqüência de amostragem de 160 determinações por hora. O procedimento analítico foi empregado com sucesso na determinação de glicose em mel, soro glicosado, suco de uva e suco de tomate. Para a determinação de glicose em plasma sanguíneo, o modulo de análise foi reconfigurado, a fim de se minimizar a manipulação da amostra. Os resultados obtidos na determinação de glicose em plasma sanguíneo, empregando o procedimento proposto, foram concordantes com o método comparativo a um nível de confiança de 95%. No procedimento analítico para a determinação de colesterol em ovos foi empregado um reator enzimático, no percurso analítico, contendo a enzima colesterol oxidase imobilizada, o H2O2 foi também monitorado pela reação quimiluminescente. A linearidade de resposta obtida, após a otimização do sistema em fluxo, foi de 250 a 2500 mg L-1 descrito pela equação: Intensidade (mV)= 43,0 + 0,325*[colesterol], R= 0,999, com consumo de 356 µg e 2,64 mg de luminol e hexacianoferrato (III) de potássio por determinação. O modulo de análise foi reconfigurado para a determinação de colesterol em plasma sangüíneo, apresentando resultados concordantes com o método comparativo. Foram realizados também estudos de extração e prépurificação da enzima peroxidase, catalisador da reação quimiluminescente, entre o luminol e H2O2.

Page generated in 0.062 seconds