• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 975
  • 16
  • 16
  • 15
  • 15
  • 11
  • 9
  • 3
  • 3
  • 3
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 994
  • 994
  • 577
  • 427
  • 417
  • 290
  • 177
  • 138
  • 122
  • 105
  • 99
  • 85
  • 71
  • 70
  • 65
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
241

Estudo dos micromecanismos de deformação e fratura da liga de Titânio Ti-6AI-4V utilizando-se técnicas de microscopia eletrônica e difração de Raios- X / Study of deformation and fracture micromechanisms of titanium alloy Ti-6Al-4V using electron microscopy and X-ray difraction techniques

Aparecido Edilson Morcelli 18 December 2009 (has links)
A realização do presente trabalho permitiu o estudo dos micromecanismos de deformação e fratura da liga de titânio Ti-6Al-4V, utilizada comercialmente para a fabricação de biomateriais metálicos. As técnicas empregadas para a análise do material em estudo foram: microscopia eletrônica de varredura (MEV), microscopia eletrônica de transmissão (MET) e a difração de raios X (DRX). Estudar a influência e comportamento das diversas fases existentes em ligas de titânio é importante para se avaliar o comportamento de trincas nas ligas de titânio com alta resistência mecânica, que possuem microestrutura fina, relacionando a presença das fases alfa (α), beta (β) e alfa+beta (α+β) com a resistência do material. A avaliação in situ dos micromecanismos de deformação e fratura foi realizada por MET e também foi feito o estudo das transformações de fase durante o resfriamento em ligas de titânio, por MET, utilizando-se as técnicas de campo claro, campo escuro e difração de elétrons (DEAS), em área selecionada. Após tratamento térmico foram observadas as diferenças entre a quantidade das fases α e β, em relação à microestrutura original do material para diferentes condições utilizadas no tratamento térmico aplicado à liga metálica. Observou-se a presença da microestrutura lamelar, formada durante o resfriamento no campo β, promovendo a transformação de parte da estrutura alfa secundária em beta, que se encontrava retida entre as lamelas de alfa. / This present work allowed the study of deformation and fracture micromechanisms of titanium alloy Ti-6Al-4V, used commercially for the manufacture of metallic biomaterials. The techniques employed for the analysis of the material under study were: scanning electron microscopy (SEM), transmission electron microscopy (TEM) and X-ray diffraction (XRD). The study of the influence and behavior of the phases present in titanium alloys is important to evaluate the behavior of cracks in titanium alloys with high mechanical strength, which have fine alpha (α), beta (β) and alpha+beta (α+β) microstructure, linking the presence of the phases with the strength of the material. The evaluation in situ of deformation and fracture micromechanisms were performed by TEM and was also a study of phase transformations during cooling in titanium alloys, using the techniques of bright field, dark field and diffraction of electrons in the selected area. After heat treatment differences were observed between the amount of in relation to the original microstructure of the β and α phases material for different conditions used in heat treatment applied to the alloy. The presence of lamellar microstructure formed during cooling in the β field was observed, promoting the conversion of part of the secondary alpha structure in β phase, which was trapped between the lamellar of alpha.
242

Estudo da agregação de copolímeros anfifílicos de poliestireno e Poli[5-(N,N-Dialquilamino) Isopreno]

Riegel, Izabel Cristina January 2002 (has links)
As propriedades em solução e a auto-associação de copolímeros em bloco de estireno e 5- (N,N-dialquilamino)isopreno foram estudados. Copolímeros di e tribloco são formados por um longo bloco de poliestireno, com um ou dois blocos menores de poli[5-(N,Ndialquilamino) isopreno] em uma ou ambas as extremidades. A polaridade do solvente é determinante na afinidade deste com um ou ambos blocos constituintes do polímero e, conseqüentemente, afetará as propriedades dinâmicas e estruturais do mesmo. Após a quaternização dos sistemas com dimetil sulfato, os agregados foram preparados pela prévia dissolução dos polímeros em um solvente orgânico e subsequente adição de água para induzir a agregação das cadeias insolúveis de PS. Solventes puros (DMF, THF e dioxano), bem como misturas de DMF e THF foram empregados como solvente comum. A concentração crítica de água (cwc) e as morfologias foram estudadas em função da natureza do solvente comum, da concentração inicial, arquitetura e massa molecular do copolímero, por espalhamento de luz estático e microscopia eletrônica de transmissão (MET), respectivamente. Determinou-se que tanto a cwc quanto as morfologias, são predominantemente influenciadas pela natureza do solvente comum. Alguns resultados inesperados foram encontrados para os copolímeros tribloco, incluindo a descoberta de uma nova morfologia formada a partir desse tipo de copolímero- a morfologia bowl-shape. Os agregados bowl-shaped, são essencialmente esferas bastante polidispersas, contendo um vazio alocado assimetricamente em seu interior. A fase contínua é composta de um arranjo de micelas inversas (núcleo de PAI e coroa de PS), sendo que as cadeias hidrofílicas de PAI circundam toda a estrutura na interface polímero/água. Acredita-se que a formação desta morfologia está sob controle cinético e não representa uma estrutura de equilíbrio. Foi proposto um possível mecanismo para a formação deste novo tipo de agregado.
243

Contribuição ao estudo tribologico dos pares acionadores de motores ultra-sonicos

Fukui, Marcelo 03 June 1996 (has links)
Orientador : Vitor Baranauskas / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-01T18:17:41Z (GMT). No. of bitstreams: 1 Fukui_Marcelo_D.pdf: 5129017 bytes, checksum: f428b49f537a6d37681249df0d1ca8de (MD5) Previous issue date: 1996 / Resumo: Apresenta-se uma análise tribológica de pares de atrito em motores ultra-sônicos de deslocamento linear. Foram analisados pares formados por diferentes materiais como aço/cerâmica de alumina, aço/diamante, cerâmica de aluminaldiamante e diamante/diamante. As amostras de diamante foram obtidas por deposição química a partir da fase vapor (CVD) e utilizadas sem nenhuma etapa de polimento. Tanto com a alumina quanto com o diamante, o aço apresentou um processo de deformação plástica formando trilhas de desgaste com dentes periódicos, os quais podem ser utilizados para a autosincronização ou para o uso destes motores como motor de passos nanométricos. O par aço-alumina apresentou problemas de tribo-oxidação levando a desgastes no aço e a geração de partículas no ar. O diamante apresentou melhores resultados mas devido ao seu baixo coeficiente de atrito a força de tração é 350 vezes maior que o par aço/alumina Os pares alumina-diamante e diamante/diamante sotteram desgastes intensos durante as vibrações ultra-sônicas, levando em ambos os casos ao rápido polimento do diamante, principalmente com o par aluminaldiamante. As morfologias das interfaces foram caracterizadas pela microscopia eletrônica de varredura e microscopia de força atômica / Abstract: A tribological study of the potential materials to be employed in linear ultrasonic motors is presented. Different pairs of materiais such as steel/alumina, steel/diamond, alumina/diamond and diamond/diamond have been studied. The diamond samples were obtained by chemical vapor deposition (CVD) and used in the ultrasonic pairs without any previous polishing. Using either alumina or diamond, the steel showed plastic deformation forming trenches with periodic features along them, which are of interest for motor autosynchronization or nanometric stepping. The steel/alumina pair showed problems of steel tribo-oxidation and of the generation of dust particles released to the atmosphere, probably fom the alumina debris. The steel/diamond pair presented the best results but due to the low lliction coefficient of diamond the tracking force was around 350 times less than for the steel/alumina pair. The diamond surface in the alumina/diamond pairs and diamond/diamond suffered intense polishing under ultrasonic vibration. The diamond polishing rate was higher is the alumina/diamond pair than in the diamond diamond pairo The morphologies of the surfaces were characterised by scanning electron microscopy and atomic force microscopy / Doutorado / Doutor em Engenharia Elétrica
244

Avaliação de materiais restauradores em cavidades retrogradas preparadas com pontas ultra-sonicas

Gondim Junior, Eudes 16 October 2002 (has links)
Orientador : Francisco Jose de Souza Filho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-02T19:42:40Z (GMT). No. of bitstreams: 1 GondimJunior_Eudes_D.pdf: 7941631 bytes, checksum: a8b9f4b39b84e33266c5bdd50686a830 (MD5) Previous issue date: 2002 / Resumo: O objetivo deste estudo foi comparar, usando réplicas de resina epóxica, a topografia de superfícies apicais de caninos humanos contento cavidades retrógradas preparadas com pontas ultra-sônicas antes e depois de seu preenchimento e acabamento com três diferentes técnicas. Também foi realizada uma avaliação quantitativa da capacidade de selamento marginal dessas obturações retrógradas. Oitenta e uma cavidades retrógradas preparadas em caninos humanos foram divididas em grupos de 27 cada. As cavidades foram preenchidas com Super-EBA, IRM, ou ProRoot-MTA e receberam um acabamento inicial com um brunidor de formato arredondado. Dezoito raízes de cada grupo receberam um acabamento final com brocas carbide de tungstênio 30 lâminas (9 raízes) ou com brocas de 28 mm Zekrya (9 raízes). Fotomicrografias de cada espécime obtidas com um microscópio eletrônico de varredura (MEV), antes e depois do preenchimento das cavidades retrógradas, foram comparadas através de um programa de análise de imagens. Após a análise da interface retrobturação/ dentina os espécimes foram preparados e imersos em uma solução de azul de metileno 2% por 12 horas. As raízes foram então trituradas e preparadas para análise em um espectrofotômetro de absorbância. Resultados obtidos mostraram que quando uma broca foi utilizada para um acabamento final nos materiais, uma área significativa (p < 0,05) de ranhuras marginais foi eliminada. A técnica de acabamento não afetou significativamente (p > 0,05) a incidência de fendas nos grupos retrobturados com MT A ou IRM. As obturações retrógradas feitas com Super EBA e IRM, e acabadas com um brunidor ou com brocas Zekrya apresentaram áreas calculadas das fendas significativamente (p < 0,05) maiores que as retrobturações feitas com MT A. Com relação à infiltração os resultados revelaram que o Pro Root MT A apresentou uma média de infiltração significativamente (p < 0,05) menor que retrobturações de Super-EBA e IRM. O fator técnica de acabamento não afetou significativamente (p > 0,05) a incidência de infiltração entre os materiais testados. O coeficiente de correção de Pearson indica que há uma associação positiva de 55,61 % entre as variáveis, ou seja, o acréscimo da quantidade de corante infiltrado está associado com o acréscimo da área de desadaptação das cavidades retrógradas / Abstract: The aim of this study was to compare, using epoxy resin replicas, the surface topography of root ends following ultrasonic preparation, and again after root-end fillings submitted to three different finishing techniques. A quantitatively evaluation of the sealing ability of Super-EBA, IRM and Pro Root MTA root-end fillings was also performed. Eighty-one ultrasonically root-end cavities prepared in human canines, were divided at random into three test groups of 27 each. The cavities were filled with Super-EBA, IRM, or ProRoot-MT A and finished by ball burnishing. Eighteen roots from each group received a final smoothing with either a 30-fluted tungsten carbide finishing bur, or a Zekrya carbide 28 mm bur. Scanning electron micrography (SEM) pictures of each sample were taken prior to and after root-end filling, and dentin/retrofilling interfaces inspected and compared with the aid of an image and analysis system. Samples were then prepared and immersed in 2% methylene blue dye solution for 12 hours. Roots were ground into a powder and prepared for analysis in an absorbency spectrophotometer. Results showed that when a finishing bur was used to finish the set materials, a significant (p < 0.05) area of marginal chipping was eliminated. The fishing technique did not significantly (p > 0.05) affect the incidence of gaps in groups retrofilled with MT A or IRM. Super EBA and IRM retrofillings finished with a ball burnisher or a Zekrya bur displayed a significantly (p < 0.05) larger calculated gap area than roots filled with MT A. In relation to microleakage the results revealed that Pro Root MT A displayed a significantly inferior mean dye microleakage (p < 0.05) than Super-EBA and IRM retrofillings. The finishing technique did not significantly (p > 0.05) affect the incidence of microleakage among the materials tested. The correlation coefficient of Pearson indicates that there is a positive, 55.61% association between the variables and this coefficient, that is, the increase of the quantity of infiltrated dye is associated with the increase of the root-end filling marginal disruption area / Doutorado / Endodontia / Doutor em Clínica Odontológica
245

Analise experimental da cinetica de secagem da alga marinha Sargassum sp

Cavalcante, Josilene de Assis 20 March 2003 (has links)
Orientadores : Sandra Cristina dos Santos Rocha, Meuris Gurgel Carlos da Silva / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Quimica / Made available in DSpace on 2018-08-03T04:06:14Z (GMT). No. of bitstreams: 1 Cavalcante_JosilenedeAssis_D.pdf: 7170954 bytes, checksum: da9ece3cce29b75a4e495f8832fcfce9 (MD5) Previous issue date: 2003 / Doutorado / Engenharia de Processos / Doutor em Engenharia Química
246

Sintese e caracterização de nanovidros de silica para preforma de fibra optica

Tomiyama, Masahiro 03 August 2018 (has links)
Orientador: Carlos Kenichi Suzuki / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-03T16:33:35Z (GMT). No. of bitstreams: 1 Tomiyama_Masahiro_D.pdf: 6209654 bytes, checksum: 3fc0f90a6c9e466ecf892fcf5fdf6e92 (MD5) Previous issue date: 2003 / Doutorado
247

Anodização de ligas de aluminio por corrente pulsada

Regone, Natal Nerimio 03 August 2018 (has links)
Orientador: Celia Marina Alvarenga Freire / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-03T21:12:04Z (GMT). No. of bitstreams: 1 Regone_NatalNerimio_D.pdf: 7846072 bytes, checksum: 7b9d73211e61fea4842f739fc2d0df32 (MD5) Previous issue date: 2004 / Doutorado
248

Avaliação da micromorfologia da interface adesiva composta por diferentes tipos de sistemas

COSTA, Daene Patrícia Tenório Salvador da 31 January 2009 (has links)
Made available in DSpace on 2014-06-12T22:58:26Z (GMT). No. of bitstreams: 2 arquivo4058_1.pdf: 7946496 bytes, checksum: a9fd143f8820a5f21e28b5028c89eff7 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2009 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Este estudo objetivou verificar a relação entre diferentes composições de sistemas adesivos convencionais ou autocondicionantes e a qualidade da interface adesiva alcançada. Foram obtidos 50 discos dentários a partir de terceiros molares humanos extraídos, os quais foram divididos em 10 grupos. A técnica de condicionamento total foi usada em 6 grupos, seguida dos adesivos One Coat Bond SL (Coltène Whaledent), AdperTM Single Bond 2 (3M/ESPE), Master Bond (Biodinâmica), XP Bond (Dentsply), Stae (SDI) e Prime & Bond® NT (Dentsply). Nos demais grupos foram utilizados 4 adesivos autocondicionantes: AdperTM PromptTM (3M/ESPE), AdheSE (Ivoclar Vivadent), Go! (SDI) e Clearfil SE Bond (Kuraray Medical). Cada adesivo recebeu dois incrementos de 1 mm de resina composta e, após 24h em água destilada, os discos foram seccionados para análise em MEV. Os adesivos autocondicionantes apresentaram menores valores de tamanho dos tags quando comparados aos adesivos convencionais, em especial na presença de partículas de carga; formaram camadas híbridas mais espessas com os que possuíam acidez forte ou acetona na sua composição; e ainda, foi encontrado menor número e comprimento de tags no adesivo autocondicionante à base de água e maior pH. Em relação aos adesivos convencionais não houve influência da adição de partículas de carga na qualidade da interface adesiva, nem do tipo de solvente, exceto quando utilizado o butanol terciário, que propiciou a menor formação de número e comprimento de tags
249

Ação do veneno total de Bothrops pirajai e de suas frações miotoxicas piratoxinas I e III sobre a musculatura esqueletica : estudos in vitro

Costa, Patricia Dourado 24 July 2018 (has links)
Orientadores: Maria Alice da Cruz-Hofling, Lea Rodrigues-Simioni / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-07-24T21:59:09Z (GMT). No. of bitstreams: 1 Costa_PatriciaDourado_M.pdf: 12162774 bytes, checksum: bc20d738d02786ba6422eeb6cadaf073 (MD5) Previous issue date: 1999 / Resumo: Várias são as motivações que levam ao estudo de substâncias naturais podendo ser citadas, a caracterização dos seus princípios ativos e dos seus efeitos biológicos. Dentre estas, ocupam lugar de destaque os venenos ofídicos, uma vez que é freqüente o envenenamento acidental causado por picada de serpentes, nos países de clima tropical. No Brasil, os acidentes ofídicos representam problema de Saúde Pública, sendo o gênero Bothrops responsável por cerca de 90% dos casos. Dentre os efeitos sistêmicos e locais, destaca-se a mionecrose que se manifesta rapidamente, é de difícil controle e merece atenção especial nas estratégias de tratamento. A mionecrose é provocada por proteínas miotóxicas que atuam especificamente no sítio da picada. Frente à escassez de estudos quanto à ação biológica do veneno da serpente Bothrops pirajai ("jararacussu da Bahia") uma espécie rara e exclusiva do estado da Bahia e nordeste de Minas Gerais, o presente trabalho foi proposto com o objetivo de investigar as possíveis atividades miotóxica e neurotóxica do seu veneno total e de suas frações isoladas, Piratoxina-I (prTX- I) e Piratoxina-III (PrTX-III). Para o estudo, foram utilizadas preparações neuromusculares, nervo frênico-diafragma (NFD) e extensor longo dos dedos (EDL) de camundongos. Os parâmetros utilizados foram a técnica miográfica, a determinação de creatinoquinase (CK), análise histológica e ultraestrutural. O veneno total e a fração PrTX-III nas doses de 10, 25 e 50 µg/ml causaram bloqueio dose-dependente da resposta contrátil do músculo EDL, alterações morfológicas e ultraestrututais com elevada liberação da enzima creatinoquinase (CK) na cuba. A miotoxina PrTX-I provocou bloqueio dose-dependente (doses de 5, 10 e 20 µg/ml) da resposta contrátil do músculo diafragma de camundongo e severa mionecrose constatada pela análise histológica do tecido. No entanto, esta fração não provocou alterações miográficas ou histológicas no músculo EDL. Essas diferenças quanto à sensibilidade foram provavelmente devidas às diferenças entre o EDL e o diafragma, que diferem quanto às quantidades de fibras de contração rápida e lenta. Nossos resultados sugerem que a miotoxina PrTX-I e a fração PrTX-III do veneno total de B. pirajai seriam os componentes responsáveis pela atividade miotóxica do veneno, muito embora haja evidência de que seus modos de ação podem ser distintos. Além disso, os resultados preliminares com a fração PrTX-III apontam para uma potente ação neurotóxica, fato observado também com o veneno total. / Abstract: Several reasons can be cited which motivate the study of natural substances such as the characterization of the active principles and its biological effects. Among them, the ophidic venoms stand out because it is common the occurrence of accidental envenomation after snake bites in tropical countries. In Brazil, ophidic accidents account for a major part in the context of Public Health were the genus Bothrops is responsable for about 90% of them. Myonecrosis is one ofthe local effects whose rapid onset is difficult to control and deserves special attention in the treatment approaches after envenomation. Myonecrosis is triggred by myotoxic proteins specifical1y acting in muscle fibers at the bite site. Due to the scarcity of studies about the biological actions of Bothrops pirajai (li jararacussu of Bahia") snake venom, arare and exclusive specimen living in Bahia and northeastrn of Minas Gerais, the present work was proposed viewing to investigate miotoxic and neurotoxic activities of crude venom and its fractions Piratoxin-I (PrTX-I) and Piratoxin-III (PrTX-III). The studies were performed in mice isolated muscle preparations of the extensor'digitorum longus (EDL) and phrenic nerve-diaphragm (PND) muscles through myographic, histological and ultrastructural analysis and determination of creatinokinase (CK) in the incubation bath. The venom and the fraction PrTX-III (10, 25 and 50 µg/ml) caused a dose-dependent twitch-tension blockade of the EDL muscle fibers, histological and ultrastructural changes of muscle cells and nerve endings culminating in complete necrosis of both and increased CK release in the bath. PrTX-I caused a dose dependent blockade (5, 10 and 20 µg/ml) onhe twitch tension in PND muscle fibers and severe myonecrosis. However, PrTX-I did not affect muscle fibers nor caused alter(!.tions on the twitch tension responses in EDL. These differences could be accounted for a distinct sensitivity of EDL and PND muscle fibers to the venom and PrTX-I possibly related to the amount of slow- and fast-contracting fibers present in each one. Our results suggest that PrTX-I and PrTX-III of B. pirajai venom would be the components accounting for the myotoxic activity of venom despite a distinct mechanism of action could be implied. Additionally, these preliminary results suggest a potent neurotoxic activity, also observed with the whole venom. / Mestrado / Farmacologia / Mestre em Ciências
250

Estudos dos efeitos do preparo sonico e ultra-sonico de cavidades retrogradas em dentes recem extraidos : analise de replicas com microscopio eletronico de varredura

Gondim Junior, Eudes 12 February 1999 (has links)
Orientador: Francisco Jose de Souza Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-25T20:14:41Z (GMT). No. of bitstreams: 1 GondimJunior_Eudes_M.pdf: 15092413 bytes, checksum: 3f9169afbcc9508c7640e8b12602e3e8 (MD5) Previous issue date: 1999 / Resumo: A nova geração de instrumentos sônicos e ultra sônicos desenvolvidas para o preparo de cavidades retrógradas vem tomando os preparos mais conservadores, profundos e alinhados ao longo eixo do canal radicular. Entretanto, estudos "in vitro" mostram o aparecimento de ranhuras e microfraturas nas superfícies seccionadas submetidas a estes tratamentos. O possível aparecimento de microfraturas em ápices estreitos e frágeis devido a ação vibratória destes sistemas é preocupante. Os objetivos deste estudo foram: avaliar a integridade das superfícies apicaisseccionadas depois da utilização de pontas sônicas e ultra-sônicas para preparos retrógrados; determinar se estruturas radiculares mais finas e pequenas são mais susceptíveis a ação destes instrumentos; comparar quantitativamente a qualidade das cavidades retrógradas. Cinco grupos formados por 16 dente~ anteriores humanos recém extraídos divididos por tipos de dentes e por tamanhos (pequenos e grandes) foram preparados das seguintes formas: tratamento 1- apicectomia e preparo ultra-sônico retrógrado com pontas' KIS; tratamento 2- apicectomia e preparo ultra-sônico retrógrado com as pontas Satelec S-12 (sem diamante); tratamento 3 apicectomia e preparo com o sistema sônico Sonicflex e pontas diamantadas; tratamento 4- apicectomia e preparo ultra-sônico retrógrado com pontas Satelec S-12D (diamantadas). Répiicas das superfícies apicais seccionadas pré e pós-operatórias foram feitas através de moldagens de siloxano. Com o auxílio de um programa de análise de imagens, as imagens das réplicas feitas com um microscópio eletrônico de varredura foram avaliadas com relação às dimensões e a presença de microfraturas ou ranhuras. Os resultados mostraram não haver diferenças estatisticamente significativas em relação à presença de microfraturas ou ranhuras entre os tipos de dente, tratamentos e tamanho das raízes (p>O,05). O tratamento 3 produziu as cavidades menos conservadoras quando comparado aos outros tratamentos, tomando desaconselhável sua utilização em raízes pequenas como as dos incisivos inferiores / Abstract: The new generation of sonic and ultrasonic root-end preparation devices has simplified the rreparation of conservative and sufficiently deep cavities that follow the original path of the root canal. However, "in vitro" studies have demonstrated microfractures and marginal chipping in resected roots after the use of such instruments. The occasional appearance of lines of infraction when vibratory action of sonic and ultrasonic instruments are applied on narrow or more fragile apices raised some concem. The purposes of this study were: to evaluate the integrity of resected root-end surfaces after using sonic and ultrasonic tips for retrograde preparation; to determine if finer and smaller roots are more susceptible to sonic and ultrasonic vibratory action; to compare quantitatively the quality of the root-end cavities. Five groups of 16 freshly extracted hurnan anterior teeth divided by anatomic group and size (small or big) were prepare.d as follows: treatment 1 - root-end resection and root-end cavity preparation with KIS ultrasonic retrotips; treatment 2 - resection and preparation with Satelec S-12 (no I diamond coated) ultrasonic retrotips; treatment 3- resection and preparation with a diamond-coated retrotip driven by a sonic device; treatment 4- resection and preparation with Satelec S-12D (diamond coated) ultrasonic retrotips. The resected pre-operative and postoperative root surfaces were replicated with polyvinylsiloxane impressions. With the aid of image processing and analysis system, the replicas were inspected under a Scanning electron microscope for further evaluation of shape quality and presence of cracks and marginal chipping. The results showed no significant difference in cracking or chipping amongst anatomic groups, treatments and tooth size (p>O.05). Treatment 3 produced less conservative cavities than the other three treatments and should not be used on small teeth as lower incisors / Mestrado / Endodontia / Mestre em Clínica Odontológica

Page generated in 0.0482 seconds