• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 162
  • 101
  • 14
  • 13
  • 12
  • 8
  • 6
  • 4
  • 3
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 364
  • 200
  • 148
  • 124
  • 63
  • 59
  • 56
  • 45
  • 43
  • 41
  • 40
  • 38
  • 35
  • 33
  • 32
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
211

Ferramentas de interação e gerenciamento do BancoWeb: uma base de imagens para auxílio a pesquisas na área de mamografia digital / Interaction and management tools of BancoWeb: a database of images to aid research in the area of digital mammography

Pâmela Serra Rodrigues 23 November 2018 (has links)
O BancoWeb é uma base de imagens para auxilio a pesquisa na área de mamografia digital. Oferece o gerenciamento da base de dados com um conjunto amplo de imagens mamográficas de qualidade apropriada ao processamento digital e, principalmente, comparação entre diferentes esquemas. O sistema de busca da base de dados/imagens mamográficas está disponível desde 2010, sendo on-line e gratuito. Com os avanços em pesquisas durante todos estes anos, a necessidade e demanda de melhorias, mudanças e incrementos no sistema de gerenciamento e buscas foram surgindo. Por isso, os objetivos deste trabalho estão em desenvolver e aperfeiçoar recursos na busca de imagens, tipos de achado, permitir a classificação pelo sistema CAD, além de implementar um novo sistema de gerenciamento e armazenamento de imagens de um novo phantom, desenvolvido como resultado de pesquisa ainda mais recente no grupo. Testes comparativos com outras bases análogas que disponibilizam imagens mamográficas para download faz do BancoWeb uma ferramenta única e poderosa para o pesquisador e interessado da área, oferecendo mais opções que as demais bases disponíveis atualmente. / BancoWeb is a database of images to aid research in the field of digital mammography. It offers the management of the database with a wide set of mammographic images of appropriate quality to the digital processing and, mainly, comparison between different schemes. The database search system/mammographic images are available since 2010, being online and free. With advances in research over the years, the need for and demand for improvements, changes, and increases in the management and search system have been emerging. Therefore, the objectives of this work are in development and improvement of resources in the search of images, types of find, allow the selection of CAD, in addition to implementing a new system of management and storage of images of a new phantom, developed as a result of even more recent research in the group. Comparative tests with other analogous databases that provide mammographic images for download makes BancoWeb a unique and powerful tool for the researcher and the interested party, offering more options than the other databases currently available.
212

Modelo de processamento de imagens mamográficas para detecção de agrupamentos de microcalcificações. / A model of mammography image processing for microcalcifications clusters detection

Evanivaldo Castro Silva Júnior 06 April 2009 (has links)
O objetivo principal deste projeto foi desenvolver um modelo para a detecção de clusters de microcalcificações para o processamento de imagens mamográficas inteiras. O modelo foi subdividido em três etapas sendo na primeira realizado um pré-processamento para a melhoria da qualidade das imagens mamográficas no que se refere à remoção de ruídos e alargamento de contraste. Na segunda etapa do processamento, um conjunto de algoritmos foi aplicado visando-se a detecção propriamente dita de regiões de interesse nas imagens as quais possivelmente representariam os agrupamentos de microcalcificações. A terceira etapa destinou-se à classificação das regiões pré-selecionadas na etapa anterior para a determinação final dos achados verdadeiro-positivos (VP), buscando-se, assim, a diminuição da taxa de achados falso-positivos (FP). Em cada etapa do desenvolvimento do modelo, testes computacionais foram realizados a fim de auxiliarem na análise de resultados preliminares. Por fim, vários testes computacionais foram realizados em três conjuntos de imagens com composições distintas sendo o primeiro formado por regiões de interesse (RI) de phantoms, o segundo por RI de mamografias e o terceiro por imagens mamográficas inteiras. Propõe-se a integração das técnicas propostas ao sistema CAD em desenvolvimento pelo grupo de pesquisa do LAPIMO (Laboratório de Análise e Processamento de Imagens Médicas e Oftalmológicas) da Escola de Engenharia de São Carlos do presente instituto. / The main purpose of this project was to develop a new model for the detection of microcalcifications clusters for image processing in full mammograms. The model was subdivided in three stages being in the first accomplished a pre-processing for the improvement of the quality of the mammographic images through the removal of noise and contrast enlargement. In the second stage of the processing, a group of algorithms was applied being sought the detection properly said of regions of interest (ROI\'s) in the images which possibly would represent the microcalcifications clusters. The third stage was destined to the classification of the pre-selected areas in the previous stage for the final determination of the true-positive findies (TP), being looked for, like this, the decrease of the rate of false-positive (FP) ones. In each stage of the development of the model, computational tests was accomplished in order to analyze the preliminary results. Finally, several computational tests was accomplished in three groups of images with different compositions being the first formed by ROI\'s of phantoms, the second by ROI\'s of mammograms and the third for full mammograms. Is proposed too the integration of the techniques proposed to the CAD scheme in development for the group of research of LAPIMO (Laboratory of Analysis and Processing of Medical and Ophthalmology Images) of the University of São Paulo, São Carlos of the present institute.
213

Método de simulação da redução da dose de radiação na mamografia digital a partir da análise das características do ruído dos equipamentos mamográficos / Method for simulating dose reduction in digital mammography through the analysis of the noise characteristics of the mammographic equipment

Lucas Rodrigues Borges 22 July 2015 (has links)
Este trabalho tem como objetivo o desenvolvimento de um novo método para a simulação de redução da dose de radiação em imagens mamográficas clínicas. Assim, estudos sobre a influência da redução da dose de radiação no diagnóstico do câncer de mama podem ser realizados sem que o paciente se exponha a doses extras de radiação. Uma análise preliminar foi realizada para a caracterização do ruído produzido pelo equipamento mamográfico no processo de aquisição da imagem. Essa análise evidenciou a importância de um método local de simulação, uma vez que o ruído depende da posição ao longo do campo. O novo método proposto consiste em ajustar os níveis de cinza e adicionar uma máscara de ruído Poisson, dependente do sinal, nas imagens clínicas adquiridas com a dose de radiação padrão, simulando sua aquisição com doses de radiação reduzidas. A dependência entre ruído e sinal foi criada com o uso da transformada de Anscombe. O desempenho do método proposto foi avaliado utilizando-se imagens mamográficas de um phantom antropomórfico obtidas com diferentes doses de radiação. As imagens simuladas pelo método proposto foram comparadas com as imagens reais. A similaridade entre os espectros de ruído permitiu a comparação de métricas locais da imagem. O erro percentual entre os níveis de cinza das imagens reais e simuladas se manteve inferior a 1%. O ruído adicionado manteve um erro percentual inferior a 1%. Testes de t-Student mostraram que não existe diferença estatística significante (p < 0,05) entre as imagens reais e simuladas pelo método proposto. / This work aims to develop a new method for simulating reduction of the radiation dose in clinical digital mammography. Using such method, studies regarding the influence of dose reduction in cancer diagnosis can be performed without unnecessary exposure of patients to X-ray radiation. A preliminary study characterized the noise produced by the digital mammography equipment during the acquisition process. This analysis emphasized the importance of simulating noise locally, since noise is dependent on the spatial position of the pixel. Therefore, the proposed method consists of adjusting the gray levels and adding signal-dependent Poisson noise to images acquired at the standard radiation dose. Dependency between noise and signal was created using the Anscombe transformation. The performance of the proposed method was evaluated using mammographic images of an anthropomorphic phantom acquired at different radiation doses. Images simulated using the proposed method were compared to real images acquired using the clinical equipment. Similarity between noise power spectra and local metrics validated the similarity between images. The gray level of the simulated and real images were compared using local mean and reported averaged errors smaller than 1%. The added noise was also compared and the averaged error was smaller than 1%. Statistical Student\'s t-test tests showed no statistical difference (p < 0.05) between real images and the ones simulated using the proposed method.
214

Caracterização de sinais secundários em imagens mamográficas por redes neurais artificiais para auxílio ao diagnóstico do câncer de mama / Characterization of secondary signals in mammographic images by artificial neural networks to aid diagnosis of breast cancer

Renan Caldeira Menechelli 25 February 2013 (has links)
O constante aumento do número de novos casos de câncer de mama vem despertando interesse na elaboração de módulos de esquemas CAD a fim de proporcionar um diagnóstico de maior precisão. Entretanto, a maioria das pesquisas está empenhada em detectar ou classificar fatores primários presentes em imagens mamográficas, como módulos e microcalcificações. Áreas assimétricas, retração de mamilo, linfonodos axilares, entre outros, são considerados como fatores secundários no diagnóstico do câncer de mama, apesar de poderem alertar para o surgimento não só dessa, mas de outras doenças no futuro. Por isso, essa pesquisa contempla a implementação de um sistema computacional capaz de auxiliar na detecção e classificação, conforme padrão BI-RADS®, de regiões que contenham sinais secundários capazes de levantar suspeitas da presença ou surgimento do câncer de mama, em imagens mamográficas digitais, utilizando técnicas inteligentes e automáticas de processamento de imagens e redes neurais artificiais. A acurácia alcançada em cada etapa foi: detecção de assimetria de 82,8%, retração de mamilo de 95% e Az = 0,93, detecção de linfonodos axilares = 74,9%. Objetiva-se que o resultado do trabalho seja inserido como um dos módulos de um protótipo de esquema CADx em mamografia, a fim de ampliar o conjunto de informações a serem usadas na classificação de cada caso sob análise, visando o aumento da precisão diagnóstica. / The increase in the number of cases of breast cancer have attracted interest in developing modules of CAD schemes to provider higher diagnostic accuracy. However, most researches are engaged in detect and classify primary factors present in mammographic images such as nodules and microcalcifications. Asymmetric areas, nipple retraction, axilary limph nodes, among other, are considered as secondary factors to diagnostic the breast cancer, although they may alert for the emergence not only of this but of other diseases in the future. Thus, this research includes the implementation of a computer system able to assist in the detection and classification, according to BI-RADS®, of regions that containing secondary signals able to arousing suspicion of the presence or appearance of breast cancer in digital mammographic images using intelligent and automatic techniques in the image processing and artificial neural networks. The accuracy obtained in each step was: detection of asymmetry of 82.8%, nipple retraction of 95% and Az = 0.93, detection of axilary lymph nodes = 74.9%. The purpose is that the result of the work is entered as one of the modules of a prototype of CADx schem in mammography in order to extend the range of information to be used in the classification of each case under analysis, aiming to increase diagnostic accuracy.
215

Ferramentas de interação e gerenciamento do BancoWeb: uma base de imagens para auxílio a pesquisas na área de mamografia digital / Interaction and management tools of BancoWeb: a database of images to aid research in the area of digital mammography

Rodrigues, Pâmela Serra 23 November 2018 (has links)
O BancoWeb é uma base de imagens para auxilio a pesquisa na área de mamografia digital. Oferece o gerenciamento da base de dados com um conjunto amplo de imagens mamográficas de qualidade apropriada ao processamento digital e, principalmente, comparação entre diferentes esquemas. O sistema de busca da base de dados/imagens mamográficas está disponível desde 2010, sendo on-line e gratuito. Com os avanços em pesquisas durante todos estes anos, a necessidade e demanda de melhorias, mudanças e incrementos no sistema de gerenciamento e buscas foram surgindo. Por isso, os objetivos deste trabalho estão em desenvolver e aperfeiçoar recursos na busca de imagens, tipos de achado, permitir a classificação pelo sistema CAD, além de implementar um novo sistema de gerenciamento e armazenamento de imagens de um novo phantom, desenvolvido como resultado de pesquisa ainda mais recente no grupo. Testes comparativos com outras bases análogas que disponibilizam imagens mamográficas para download faz do BancoWeb uma ferramenta única e poderosa para o pesquisador e interessado da área, oferecendo mais opções que as demais bases disponíveis atualmente. / BancoWeb is a database of images to aid research in the field of digital mammography. It offers the management of the database with a wide set of mammographic images of appropriate quality to the digital processing and, mainly, comparison between different schemes. The database search system/mammographic images are available since 2010, being online and free. With advances in research over the years, the need for and demand for improvements, changes, and increases in the management and search system have been emerging. Therefore, the objectives of this work are in development and improvement of resources in the search of images, types of find, allow the selection of CAD, in addition to implementing a new system of management and storage of images of a new phantom, developed as a result of even more recent research in the group. Comparative tests with other analogous databases that provide mammographic images for download makes BancoWeb a unique and powerful tool for the researcher and the interested party, offering more options than the other databases currently available.
216

Densidade mamária e polimorfismo do gene do receptor estrogênico em mulheres com mamas densas após a menopausa / Breast density and polymorphism of the estrogen receptor gene in women with hight breast density after menopause

Marilene Alícia Souza 19 October 2012 (has links)
Introdução: Polimorfismo é variação genética de ocorrência habitual na população em geral, encontrado em frequência superior a 1%. Há vários polimorfismos conhecidos no gene do receptor estrogênico alfa, alguns dos quais podem modificar a função do receptor e a ação dos estrogênios. Associação de polimorfismos no gene do receptor estrogênico alfa e risco de doenças, incluindo o câncer de mama, tem sido objeto de grande interesse, porém existem poucos estudos publicados sobre a prevalência destes na população brasileira. Objetivos: Verificar em mulheres com mamas densas após a menopausa; 1) A distribuição dos fatores de risco para câncer de mama; 2) A frequência dos polimorfismos do gene do receptor estrogênico alfa Pvull, Xbal e (GT)n; 3) A associação entre os resultados moleculares e os fatores de risco para o câncer de mama. Casuística e métodos: Estudo observacional realizado na divisão de Clínica Ginecológica do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, em 308 mulheres com idade entre 45 e 65 anos, mamas densas, que estavam há pelo menos um ano sem menstruar, que não faziam uso de terapia hormonal há 1 ano ou mais e sem antecedente pessoal de câncer de mama e ovário. Caracterizaram-se na história clínica e no exame físico, idade da menarca e da menopausa, paridade, idade ao nascimento do primeiro filho, antecedentes familiares de câncer de mama, hábito de fumar, ingestão de bebida alcoólica e o Índice de Massa Corpórea. Foi coletada amostra de sangue periférico para extração do DNA genômico e determinação dos polimorfismos presentes no intron 1 (Pvull e Xbal) e na região promotora do éxon 1 (GT)n e dosagens de glicemia, colesterol total e frações, insulina, IGF1, TSH, T3, T4, FSH, LH e estradiol. Resultados: Os fatores considerados de risco para o câncer de mama, menarca antes dos 12 anos (35,38%), nuliparidade ou idade ao ter o 1º filho após os 28 anos (41,66%), história familiar de câncer de mama (19,16%) e sobrepeso/obesidade (62,01%) foram mais prevalentes nessa população. A cor branca foi a mais frequente, coincidindo com os resultados de outros estudos, e a menopausa tardia não se mostrou um fator de influência nessa população. As frequências alélica e genotípica para os SNPs no RE?-397-Pvull e Xbal foram: P=43,99%; p=56,01%; pp=32,14%, Pp=47,73% e PP=20,13%; X=41,56%, x=58,44%; xx=33,44%, Xx=50,00% e XX=16,56%, respectivamente. Para o polimorfismo de repetição STRs (GT)n, os genótipos mais frequentes foram 14, 15 e 16, com predomínio da repetição 16. As distribuições alélica e genotípica dos polimorfismos (Pvull, Xbal e GTn), não sofreram influências significativas dos fatores de risco pesquisados. Conclusão: Os fatores de risco para o câncer de mama foram mais prevalentes nessa população de mulheres com mamas densas, embora, não tenham mostrado associações significativas com os polimorfismos estudados. Estudos caso controle adicionais são necessários para melhor compreender a associação destes polimorfismos e o câncer de mama. / Introduction: Polymorphism is genetic variation of usual occurrence in the general population, found with frequency higher than 1%. There are several known polymorphisms in the estrogen receptor alpha (ER?), some of which can modify the receptor function and the action of the estrogen. Association of polymorphisms in the estrogen receptor alpha gene and risk of diseases, including breast cancer, has been a subject of great interest, but there are few published studies on the prevalence of these in the Brazilian population. Objective: Checking on women with high breast density after menopause; 1) the distribution of risk factors for breast cancer; 2) the frequency of polymorphism of the estrogen receptor alpha gene Pvull, Xbal and (GT)n; 3) the association between the molecular results and the risk factors for breast cancer. Methods: Observational study carried out in the Gynecology Department of the Hospital das Clínicas of Medical School of São Paulo University, in 308 women aged between 45 and 65 years-old, high breast density, who were at least one year without menstruating and did not use hormone therapy for 1 year or more and no personal history of breast and ovarian cancer. It was characterized on clinical history and physical examination: age of menarche and menopause, parity, age at birth of first child, family history of breast cancer, smoking, alcohol intake and body mass index. Peripheral blood sample was collected for DNA extraction and determination of genomic polymorphisms present in the intron 1 (Pvull and Xbal), in the promoter region of exon 1 (GT)n, dosages of blood glucose, total cholesterol and fractions, insulin, IGF1, TSH, T3, T4, FSH, LH, and estradiol. Results: The factors considered of risk for breast cancer, menarche before age 12 (35.38%), nulliparity or first child after the 28 years-old (41.66%), family history of breast cancer (19.16%) and Overweight/obesity (62.01%) were more prevalent in this population. The Caucasian were the most frequent, coinciding with the results of other studies, and late menopause was not a factor of influence in this population. The allele and genotypic frequencies for SNPs in ER?-397-Pvull and Xbal were: P = 43.99%; p = 56.01%; pp = 32.14%, Pp = 47.73% and PP = 20.13%; X = 41.56%, x = 58.44%; xx = 33.44%, Xx = 50.00% and XX = 16.56%, respectively. For the STRs repeat polymorphism (GT)n, the most common genotypes were 14, 15 and 16, with a predominance of repeat 16. The allele and genotypic distributions of polymorphisms (Pvull, Xbal and GTn), did not suffer significant influences of the risk factors surveyed. Conclusion: The risk factors for breast cancer were more prevalent in this population of women with high breasts density, although have not shown significant associations with polymorphisms studied. Additional studies case-control are needed to better understand the Association of these polymorphisms and breast cancer.
217

Avaliação do programa de rastreamento mamográfico oportunístico realizado pelo Sistema Único de Saúde, no município de Goiânia, em 2010: desempenho dos centros de diagnóstico e indicadores para monitoramento de resultados / Evaluation of the opportunistic mammographic screening program of the Single Health System in the city of Goiânia in 2010: performance of diagnostic centers and indicators for monitoring results

Rodrigues, Danielle Cristina Netto 27 June 2012 (has links)
Submitted by Cássia Santos (cassia.bcufg@gmail.com) on 2014-09-02T12:39:57Z No. of bitstreams: 2 Dissertacao Danielle Cristina Netto Rodrigues.pdf: 2790977 bytes, checksum: a52a913367f05f805a438a386b3889da (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2014-09-02T12:39:57Z (GMT). No. of bitstreams: 2 Dissertacao Danielle Cristina Netto Rodrigues.pdf: 2790977 bytes, checksum: a52a913367f05f805a438a386b3889da (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2012-06-27 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Introduction: Among governmental measures in support of strategies to control and prevent breast cancer in Brazil, the implementation of the Breast Cancer Control Information System (SISMAMA) has made it possible for Single Health System (SUS) managers to identify users and diagnostic centers and provide data to the National Mammmogram Quality Program (PNQM) as a way of guaranteeing adequate tracking and establishing indicators for monitoring mammography results in each region of the country. Objective: To evaluate the opportunistic mammographic screening program carried out by the Single Health System in the municipality of Goiânia en 2010 in regard to the performance of diagnostic centers and indicators for monitoring results. Method: This was an ecological study in which the results of mammograms performed by SUS on the female population of Goiânia from January to December, 2010 and reported by diagnostic centers to SISMAMA were analyzed. The data were collected from the “export data” file of the state coordination module and the variables studied were analyzed in the two articles produced on the basis of this study. In Article 1, the variables studied were test production by diagnostic center, monthly test volume, tests by clinical indication, screening tests by age group and screening tests by diagnostic conclusion using BIRADS® categories (0,1,2,3,4 and 5). To evaluate the conformity of the diagnostic centers, an arbitrary variation limit of ± 30% of the relative frequency of all diagnostic centers in each BIRADS® category was established. Those centers found to be within this limit were considered to be in conformity. Centers with the same conformity percentage were considered to have the same performance. For Article 2 the variables were mammography distribution by age group, diagnostic conclusion, earlier mammograms and those indicated for biopsy. The following indicators for monitoring the results for the 50- 69 year age group were calculated: participation (coverage) rate, test rate by BIRADS® category (1,2,3,4 and 5), recall rate (BIRADS® 0), percentage of positive mammograms (BIRADS® 0, 4 and 5) and the biopsy indication rate (BIRADS® 4 and 5). Results: In Artlcle 1, of the 31,454 tests carried out on women residing in Goiânia, 8,268 (26.3%) were reported by the proprietary SUS diagnostic center network and 23,186 by the accredited network. Test distribution by age group and type of network shows that 43.3% of tests were carried out on women in the 40-49 year age bracket and 44.8% on women from 50 to 69 years old. Diagnostic conclusion performance was uneven among the diagnostic centers for BIRADS® categories 1,2,3,4 and 5 as well as for BIRADS® category 0 in comparison with the other categories, with p<0.001. In Article 2, for the 50-69 year age bracket, the biennial screening coverage estimate was 25.2% and the mammography ratio for 2010 was 0.14. The indicators for monitoring the results of the SUS opportunistic mammography screening program were the following: the recall rate was 9.6% (BIRADS® 0) and the normal test rate (BIRADS® 1 and 2) was 86.1% while the percentage of positive mammograms (BIRADS® 0, 4 and 5) was 10.9% and the biopsy indication rate was 1.3% (BIRADS® 4 and 5). Conclusion: An analysis of the results makes it possible to construct the first opportunistic mammography screening indicators for Goiânia. These will serve as parameters for monitoring early breast cancer detection measures. MMG services’ unequal diagnostic conclusion performance points to the necessity of implementing result auditing in screening programs to monitor the quality of mammographic test interpretation. / Introdução: Em meio às ações governamentais que subsidiam as estratégias para o controle e prevenção do câncer de mama no Brasil, a implantação do Sistema de Informação do Controle do Câncer de Mama (SISMAMA) possibilitou aos gestores do Sistema Único de Saúde (SUS) o mapeamento das usuárias e dos centros de diagnóstico, fornecendo dados para o Programa Nacional de Qualidade em Mamografia (PNQM), como forma de garantir um rastreamento adequado, bem como estabelecer indicadores para monitoramento dos resultados dos exames mamográficos em cada região do país. Objetivo: Avaliar o programa de rastreamento mamográfico oportunístico realizado pelo Sistema Único de Saúde, no município de Goiânia, em 2010, no que diz respeito ao desempenho dos centros de diagnóstico e aos indicadores para monitoramento dos resultados. Método: Estudo ecológico no qual foram analisados os dados reportados pelos centros de diagnóstico ao SISMAMA sobre os exames de mamografia realizados pelo SUS, no período de janeiro a dezembro de 2010, na população feminina residente no município de Goiânia, em 2010. Os dados foram levantados a partir do arquivo “exporta dados” do módulo coordenação estadual, e as variáveis estudadas foram conduzidas conforme os dois artigos produzidos por esse estudo. Para o Artigo 1, as variáveis estudadas foram: produção de exames por centro de diagnóstico, produção de exames mensal, exames por indicação clínica, exames de rastreamento por faixa etária, exames de rastreamento por conclusão diagnóstica de acordo com as categorias BIRADS® (0, 1, 2, 3, 4 e 5). Para avaliar a conformidade dos centros de diagnóstico, estabeleceu-se para a presente pesquisa um limite de variação arbitrário de ± 30% da frequência relativa apresentada por todos os centros de diagnóstico para cada categoria BIRADS®. Aqueles centros que se encontravam dentro desse limite, considerou-se que apresentavam conformidade. Considerou-se como centros de desempenho iguais, aqueles que apresentaram percentuais de conformidade iguais.. Para o Artigo 2, as variáveis foram: distribuição de mamografias por faixa etária, conclusão diagnóstica, realização de mamografia anterior e aquelas com indicação para biópsia. Foram calculados os seguintes indicadores para monitoramento dos resultados, para a faixa etária de 50 a 69 anos: taxa de participação (cobertura); taxa de exames por categoria BIRADS® (1, 2, 3, 4 e 5); taxa de reconvocação (BIRADS® 0); percentual de mamografias positivas (BIRADS® 0, 4 e 5) e taxa de indicação de biópsia (BIRADS® 4 e 5). Resultados: No Artigo 1, dos 31.454 exames realizados em mulheres residentes em Goiânia, 8.268 (26,3%) foram reportados pelos centros de diagnóstico da rede própria e 23.186 (73,7%) pela rede conveniada. A distribuição de exames por faixa etária, segundo o tipo de rede, mostra que 43,3% foram realizados na faixa de 40 a 49 anos e 44,8%, na faixa de 50 a 69 anos. Observou-se desempenho desigual na análise entre todos os centros de diagnóstico com relação à conclusão diagnóstica para as categorias BIRADS® 1, 2, 3, 4 e 5, bem como para categoria BIRADS® 0 com as outras categorias, com p<0,001. No Artigo 2, para a faixa etária de 50 a 69 anos, a estimativa de cobertura foi de 25,2% para rastreamento bienal, e a razão de mamografias para 2010 foi de 0,14. Com relação aos indicadores para monitoramento dos resultados do programa de rastreamento mamográfico oportunístico do SUS, a taxa de reconvocação foi de 9,6% (BIRADS® 0). A taxa de exames normais (BIRADS® 1 e 2) foi de 86,1%, enquanto que o percentual de mamografias positivas (BIRADS® 0, 4 e 5) foi de 10,9% e 1,3% para a taxa de indicação de biópsia (BIRADS® 4 e 5). Conclusão: A análise dos resultados permitiu a construção dos primeiros indicadores do rastreamento mamográfico oportunístico realizado em Goiânia e esses servirão de parâmetros para o monitoramento das ações de detecção precoce do câncer de mama e que a desigualdade no desempenho dos serviços de MMG na conclusão diagnóstica aponta a necessidade de implantação de auditorias de resultados em programas de rastreamento para o monitoramento da qualidade da interpretação dos exames mamográficos.
218

Estabelecimento de um sistema padrão primário para raios X de energias baixas com uma câmara de ionização de ar livre / Establishment a primary standard system for low energy X-rays using a free air ionization chamber

Natália Fiorini da Silva 22 March 2016 (has links)
Neste trabalho foi estabelecido um sistema padrão primário para raios X de energias baixas (10 kV a 50 kV), utilizando uma câmara de ionização de ar livre de cilindros concêntricos da marca Victoreen (modelo 481-5) no Laboratório de Calibração de Instrumentos (LCI) do Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP). Para isso foi desenvolvido um novo protocolo de alinhamento da câmara de ionização no sistema de radiação e foi feita uma modificação no suporte dos micrômetros utilizados para o movimento dos cilindros internos. Os resultados obtidos nos testes de estabilidade e de caracterização ficaram dentro dos limites estabelecidos pelas normas IEC 61674 e IEC 60731. Foram determinados também os fatores de correção para atenuação de fótons no ar, transmissão e espalhamento no diafragma, espalhamento e fluorescência, e recombinação iônica. Esses valores foram comparados com os valores obtidos pelo laboratório padrão primário alemão,Physikalisch-Technische Bundesanstalt (PTB), mostrando boa concordância. Por último, foi determinado o valor absoluto da grandeza taxa de kerma no ar para as qualidades padronizadas de mamografia de feixes diretos WMV28 e WMV35 e feixes atenuados WMH28 e WMH35; os resultados são compatíveis, com diferença máxima de 3,8% com os valores obtidos utilizando o sistema padrão secundário do LCI. / In this work a primary standard system was established for low energy X-rays (10 kV to 50 kV), using a free air ionization chamber with concentric cylinders, Victoreen (Model 481-5), at the Calibration Laboratory of Instruments (LCI) of the Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP). For this, a new ionization chamber alignment protocol was developed for the radiation system and a modification on the micrometer housing used for the movement of the internal cylinders was made. The results obtained for the stability and characterization tests showed to be within the limits established by the standards IEC 61674 and IEC 60731. The correction factors for photon attenuation in the air, transmission and scattering in the diaphragm, scattering and fluorescence and ion recombination were also determined. These values were compared with those obtained by the German primary standard laboratory, Physikalisch-Technische Bundesanstalt (PTB), showing good agreement. Finally, the absolute values of the quantity air kerma rate for the standard qualities direct beams MWV28 and WMV35 and the attenuated beams WMH28 and WMH35 were determined; the results are in agreement, with a maximum difference of 3,8% with the values obtained using the secondary standard system of LCI.
219

Simulação de cirurgia mamária usando Elementos Finitos com modelos reconstruídos a partir de mamografias / Simulation of breast surgery using Finite Element models reconstructed from mammograms

DINIZ, Edgar Moraes 06 May 2011 (has links)
Submitted by Rosivalda Pereira (mrs.pereira@ufma.br) on 2017-08-11T20:09:50Z No. of bitstreams: 1 EdgarDiniz.pdf: 5149375 bytes, checksum: 8cb2b4fa48d3b167b6608a2de4544221 (MD5) / Made available in DSpace on 2017-08-11T20:09:50Z (GMT). No. of bitstreams: 1 EdgarDiniz.pdf: 5149375 bytes, checksum: 8cb2b4fa48d3b167b6608a2de4544221 (MD5) Previous issue date: 2011-05-06 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPQ) / Surgery simulation is as a powerful tool to aid health care professionals. Among its applications, we can highlight virtual training, preview of surgery outcome, support for the choice of best procedure and doctor-patient communication improvement. This work presents a methodology for breast surgery simulation using solid nite elements. We build the models from mammographic images. We discuss all the steps required to build the breast nite elements model: image segmentation, breast volume reconstruction, surface mesh extraction, volume mesh generation, and breast materials de nition. The surgery is simulated by tissue removal and suture operations. An application to de ne the models was developed and the Abaqus suite is used to perform the simulations. / A simulação de procedimentos cirúrgicos apresenta-se como uma poderosa ferramenta de auxílio ao profissional de saúde. Entre suas aplicações, destacam-se treinamento virtual, previsão de resultados, auxílio na decisão do melhor procedimento a ser executado e melhoria na comunicação médico-paciente. Este trabalho apresenta uma metodologia para simulação de cirurgia mamária usando elementos finitos. Os modelos são construídos a partir de imagens de mamografia. Discutimos todas as etapas para a geração do modelo de elementos finitos da mama: segmentação das imagens, extração da malha de superficie, geração da malha volumétrica, definição dos materiais dos tecidos. A cirurgia é simulada através das operações de remoção de tecido e sutura. Foi desenvolvida uma aplicação com as funcionalidades de definição do modelo e utilizado o pacote Abaqus para a realização da simulação.
220

BancoWeb: base de imagens mamográficas para auxílio em avaliações de esquemas CAD / Mammographic image database for CAD schemes evaluation

Bruno Roberto Nepomuceno Matheus 22 April 2010 (has links)
Este trabalho teve como objetivo desenvolver uma base de imagens mamográficas online com acesso público para desenvolvimento, testes e avaliação comparativa de esquemas computadorizados de auxilio ao diagnóstico (CADs). A base contem imagens de vários hospitais, com grande variedade de laudos, também disponíveis na base assim como informações sobre dados clínicos (não confidenciais) dos pacientes. Uma interface detalhada foi criada para permitir o fácil acesso público, permitindo o uso de ferramentas de busca, recorte, analise estatística e inserção remota de imagens, entre outras. Testes comparativos com bases já existentes e amplamente usadas mostraram que a base desenvolvida tem quantidade e qualidade de imagens comparável ou superior as outras, além de oferecer uma quantidade de ferramentas muito maior. / This work has the objective of developing an online mamographic image database with public access for development, test and evaluation of computer-aided diagnosis (CAD). The database contains images from several hospitals, with great variety of medical reports, also available on the database together with other clinical information (not classified) from the patient. A detailed interface was developed to allow easy public access, allowing the use of tools for search, clipping, statistical analyses, remote insertion and others. Comparative test with other already existing databases shown that the presented database has quantity and quality comparable or superior to the others and offers a greater set of tools for the user.

Page generated in 0.0686 seconds