• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 16
  • 3
  • 3
  • 3
  • 1
  • Tagged with
  • 24
  • 24
  • 8
  • 7
  • 7
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 5
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Estudo dos fatores interferentes na adaptação marginal de próteses confeccionadas em titânio comercialmente puro e ligas alternativas / Study of determining factors for the marginal fit of prosthesis made of commercially pure titanium and alternative alloys

Soriani, Natércia Carreira 08 April 2011 (has links)
O desajuste de copings obtidos por fundição por cera perdida está sujeita à vários fatores tais como: contração de fundição do metal, expansão do revestimento, uso de espaçadores, entre outros. O objetivo do estudo foi avaliar o desajuste marginal pré e pós cimentação de copings obtidos com três ligas de metais básicos - Ni-Cr-Be (VB), Ni-Cr (V2) e Co-Cr (KE) fundidos a partir de dois revestimentos - Termocast (TE) e Microfine (MI) e Titânio comercialmente puro (TR) fundido com dois revestimentos - Rematitan Plus (RP) e Rematitan Ultra (RU), nas condições E0, sem espaçador, E1, com uma camada de espaçador e E2, com duas camadas de espaçador. A partir de uma matriz metálica, foram obtidos 240 copings, sendo 10 para cada combinação metal-revestimento-espaçador. Foi utilizado Microscópio Óptico para determinação do desajuste nas condições pré e pós cimentação, efetuada com cimento de fosfato de zinco. Foi realizado teste de tração pós cimentação para determinação da carga de remoção dos copings da combinação KE-MI. Foram realizados ensaios dilatométricos para a definição dos coeficientes de expansão térmico linear dos metais e dos revestimentos, determinação da expansão de presa dos revestimentos, além de ensaio para determinação da variação dimensional das fundições e análises de microscopia eletrônica de varredura (MEV). Os dados de desajuste marginal foram analisados estatisticamente pelos testes Anova e Student-Newman-Keulsa que revelaram significância estatística (0,05) para os fatores isolados. Para os metais, os valores de desajuste (&mu;m) foram V2 (85) = VB (89) < KE (119) < TR (171) e para os revestimentos, MI (68) < TE (128) < RP (153) < RU (188). Para o espaçador os desajustes foram E2 (76) < E1 (125) < E0 (147). Os menores valores de desajuste pós cimentação foram obtidos pelas combinações: VB-MI-E2 (44), V2-MI-E2 (47), VB-MI-E1 (52), VB-MI-E0 (55), TR-RU-E2 (67), V2-MI-E1(70), V2-TE-E2 (77), V2-MI-E0 (86), VB-TE-E2 (103), todas as demais combinações tiveram valores acima de 120 &mu;m, adotado como referência clinicamente aceitável. Houve diferença significante para as cargas de remoção entre as condições E2 (49 Kgf) < E1 (74 Kgf) < E0 (102 Kgf). Os valores de expansão de presa foram: TE (1,05%), MI (0,88%), RP (0,19%) e RU (0,02%). Para o ensaio dilatométrico, os valores de contração dos metais foram: KE (0,270%), V2 (0,262%), VB (0,256%) e TR (0,160%). Para os revestimentos, houve diferença significante, entre MI (0,74%) e RU (-1,63%). A análise da variação dimensional revelou diferença significante para os metais: V2 (0,08%) &ge; VB (-0,12%) &ge; KE (-0,21%) &ge; R (-0,85%) e para os revestimentos: MI (0,09%) > TE (-0,26%) = RP (-0,50%) > RU (-1,19%). Os revestimentos MI e RU apresentaram micro estrutura mais refinada, contendo cristais mais homogêneos e menos porosidade que os revestimentos RP e TE. Com base nos dados analisados, é válido afirmar que, embora a utilização de revestimentos com boas propriedades dilatométricas facilite a confecção de copings com ajuste marginal adequado, a utilização de espaçadores pode ser indispensável para obtenção de resultados clínicos satisfatórios. / The marginal fit of copings made by lost-wax casting are subject to different variation factors, such as contraction of molten metal, investment thermal expansion, die spacer use and others. This study aimed to evaluate the marginal adaptation of copings before and after cementation, obtained with three basic alloys - Ni-Cr-Be (VB), Ni-Cr (V2) and Co-Cr (KE), melted with two investments - Termocast (TE) and Microfine (MI) - and commercially pure titanium (TR) melted with Rematitan Plus (RP) and Rematitan Ultra (RU), in the conditions: E0 (without die spacer), E1 (one die spacer layer) and E2 (two die spacer layers). From a metal matrix, 240 copings were obtained, 10 for each combination metal-investment-spacer. An optical microscope was used to determine the misfit before and after the cementation with zinc phosphate cement. A tensile strength test was carried out after the cementation in order to determine the remotion load. Dilatometric tests were used to calculate the linear thermal expansion coefficients of metals and investments, to determine the setting expansion of the investments and to determine the dimensional variation as well. After the tests, the data were analyzed statistically. The analysis of variance for the marginal adaptation showed statistical significance (0.05) for all variation factors. For the metals, the misfit, in &mu;m, was: V2 (85) = VB (89) < KE (119) < TR (171); and for investments, MI (68) < TE (128) < RP (153) < RU (188). The misfit for factor die spacer was: E2 (76) < E1 (125) < E0 (147). Having accepted the value of 120 &mu;m as a reference limit of clinically acceptable results, the lowest misfit values for different combinations after cementation were: VB-MI-E2 (44), V2-MI-E2 (47), VB-MI-E1 (52), VB-MI-E0 (55), RU-TR-E2 (67 &mu;m), V2-MI-E1 (70), E2-V2-TE (77), V2-MI-E0 (86), VB-TE-E2 (103). All the other combinations had values above 120 &mu;m. There was a significant difference for tensile strength under the conditions E2 (49 Kgf), E1 (74 Kgf) and E0 (102 kgf). The setting expansion values were: TE (1.05%), MI (0.88%), RP (0.19%) and RU (0.02%). According to the dilatometer test, the values of contraction for the metals were: KE (0.27%), V2 (0.262%), VB (0.256%) and TR (0.16%), and for the investments: MI (0.74%) and RU (-1.63%). The analysis of variance revealed significant differences for metals dimensional variation: V2 (0.08%) &ge; VB (-0.12%) &ge; KE (-0.21%) &ge; TR (-0.85%) and investments: MI (0.09%) > TE (-0.26%) = RP (-0.50%) > RU (-1.19%). In conclusion, the use of investments with good dilatometric properties improves the marginal fit of the copings, but the die spacer use may be essential for obtaining satisfactory clinical results.
22

Estudo dos fatores interferentes na adaptação marginal de próteses confeccionadas em titânio comercialmente puro e ligas alternativas / Study of determining factors for the marginal fit of prosthesis made of commercially pure titanium and alternative alloys

Natércia Carreira Soriani 08 April 2011 (has links)
O desajuste de copings obtidos por fundição por cera perdida está sujeita à vários fatores tais como: contração de fundição do metal, expansão do revestimento, uso de espaçadores, entre outros. O objetivo do estudo foi avaliar o desajuste marginal pré e pós cimentação de copings obtidos com três ligas de metais básicos - Ni-Cr-Be (VB), Ni-Cr (V2) e Co-Cr (KE) fundidos a partir de dois revestimentos - Termocast (TE) e Microfine (MI) e Titânio comercialmente puro (TR) fundido com dois revestimentos - Rematitan Plus (RP) e Rematitan Ultra (RU), nas condições E0, sem espaçador, E1, com uma camada de espaçador e E2, com duas camadas de espaçador. A partir de uma matriz metálica, foram obtidos 240 copings, sendo 10 para cada combinação metal-revestimento-espaçador. Foi utilizado Microscópio Óptico para determinação do desajuste nas condições pré e pós cimentação, efetuada com cimento de fosfato de zinco. Foi realizado teste de tração pós cimentação para determinação da carga de remoção dos copings da combinação KE-MI. Foram realizados ensaios dilatométricos para a definição dos coeficientes de expansão térmico linear dos metais e dos revestimentos, determinação da expansão de presa dos revestimentos, além de ensaio para determinação da variação dimensional das fundições e análises de microscopia eletrônica de varredura (MEV). Os dados de desajuste marginal foram analisados estatisticamente pelos testes Anova e Student-Newman-Keulsa que revelaram significância estatística (0,05) para os fatores isolados. Para os metais, os valores de desajuste (&mu;m) foram V2 (85) = VB (89) < KE (119) < TR (171) e para os revestimentos, MI (68) < TE (128) < RP (153) < RU (188). Para o espaçador os desajustes foram E2 (76) < E1 (125) < E0 (147). Os menores valores de desajuste pós cimentação foram obtidos pelas combinações: VB-MI-E2 (44), V2-MI-E2 (47), VB-MI-E1 (52), VB-MI-E0 (55), TR-RU-E2 (67), V2-MI-E1(70), V2-TE-E2 (77), V2-MI-E0 (86), VB-TE-E2 (103), todas as demais combinações tiveram valores acima de 120 &mu;m, adotado como referência clinicamente aceitável. Houve diferença significante para as cargas de remoção entre as condições E2 (49 Kgf) < E1 (74 Kgf) < E0 (102 Kgf). Os valores de expansão de presa foram: TE (1,05%), MI (0,88%), RP (0,19%) e RU (0,02%). Para o ensaio dilatométrico, os valores de contração dos metais foram: KE (0,270%), V2 (0,262%), VB (0,256%) e TR (0,160%). Para os revestimentos, houve diferença significante, entre MI (0,74%) e RU (-1,63%). A análise da variação dimensional revelou diferença significante para os metais: V2 (0,08%) &ge; VB (-0,12%) &ge; KE (-0,21%) &ge; R (-0,85%) e para os revestimentos: MI (0,09%) > TE (-0,26%) = RP (-0,50%) > RU (-1,19%). Os revestimentos MI e RU apresentaram micro estrutura mais refinada, contendo cristais mais homogêneos e menos porosidade que os revestimentos RP e TE. Com base nos dados analisados, é válido afirmar que, embora a utilização de revestimentos com boas propriedades dilatométricas facilite a confecção de copings com ajuste marginal adequado, a utilização de espaçadores pode ser indispensável para obtenção de resultados clínicos satisfatórios. / The marginal fit of copings made by lost-wax casting are subject to different variation factors, such as contraction of molten metal, investment thermal expansion, die spacer use and others. This study aimed to evaluate the marginal adaptation of copings before and after cementation, obtained with three basic alloys - Ni-Cr-Be (VB), Ni-Cr (V2) and Co-Cr (KE), melted with two investments - Termocast (TE) and Microfine (MI) - and commercially pure titanium (TR) melted with Rematitan Plus (RP) and Rematitan Ultra (RU), in the conditions: E0 (without die spacer), E1 (one die spacer layer) and E2 (two die spacer layers). From a metal matrix, 240 copings were obtained, 10 for each combination metal-investment-spacer. An optical microscope was used to determine the misfit before and after the cementation with zinc phosphate cement. A tensile strength test was carried out after the cementation in order to determine the remotion load. Dilatometric tests were used to calculate the linear thermal expansion coefficients of metals and investments, to determine the setting expansion of the investments and to determine the dimensional variation as well. After the tests, the data were analyzed statistically. The analysis of variance for the marginal adaptation showed statistical significance (0.05) for all variation factors. For the metals, the misfit, in &mu;m, was: V2 (85) = VB (89) < KE (119) < TR (171); and for investments, MI (68) < TE (128) < RP (153) < RU (188). The misfit for factor die spacer was: E2 (76) < E1 (125) < E0 (147). Having accepted the value of 120 &mu;m as a reference limit of clinically acceptable results, the lowest misfit values for different combinations after cementation were: VB-MI-E2 (44), V2-MI-E2 (47), VB-MI-E1 (52), VB-MI-E0 (55), RU-TR-E2 (67 &mu;m), V2-MI-E1 (70), E2-V2-TE (77), V2-MI-E0 (86), VB-TE-E2 (103). All the other combinations had values above 120 &mu;m. There was a significant difference for tensile strength under the conditions E2 (49 Kgf), E1 (74 Kgf) and E0 (102 kgf). The setting expansion values were: TE (1.05%), MI (0.88%), RP (0.19%) and RU (0.02%). According to the dilatometer test, the values of contraction for the metals were: KE (0.27%), V2 (0.262%), VB (0.256%) and TR (0.16%), and for the investments: MI (0.74%) and RU (-1.63%). The analysis of variance revealed significant differences for metals dimensional variation: V2 (0.08%) &ge; VB (-0.12%) &ge; KE (-0.21%) &ge; TR (-0.85%) and investments: MI (0.09%) > TE (-0.26%) = RP (-0.50%) > RU (-1.19%). In conclusion, the use of investments with good dilatometric properties improves the marginal fit of the copings, but the die spacer use may be essential for obtaining satisfactory clinical results.
23

Avaliação da adaptação marginal e interna, da resistência à fratura após ciclagem termomecânica e das tensões nos implantes por correlação de imagens digitais em próteses parciais fixas sobre implantes com pilares e copings em zircônia com diferentes sistemas CAD/CAM / Evaluation of the marginal and internal fit, resistance to fracture after thermomechanical cycling and tensions in the implants by correlation of digital images in fixed partial dentures on implants with abutments and copings in zirconia with different CAD/CAM systems

Francielle Alves Mendes 02 June 2015 (has links)
Considerando a crescente exigência estética, o desenvolvimento da zircônia e o incremento da tecnologia CAD/CAM o objetivo deste trabalho foi avaliar a adaptação marginal e interna, as tensões nos implantes e a resistência à fratura após prensagem da porcelana e termociclagem mecânica em próteses parciais fixas sobre implantes com pilares e infraestrutura em zircônia com dois sistemas CAD/CAM (Neodent digital - Neodent e Lava - 3M ESPE) comparados com o método convencional (n=10). A adaptação marginal e interna foi analisada por meio de um microtomógrafo computadorizado (microCT). Cada prótese foi digitalizada e os arquivos foram processadas utilizando o software NRecon e CTAN. Foi utilizado o programa Dataview para aferição das medidas. Para a realização da ciclagem termomecânica as próteses foram posicionadas na máquina de fadiga mecânica por mastigação e foi aplicada a carga de 120 N com uma ponta que simula a oclusão antagonista simulando 2.000.000 ciclos. Durante o ensaio, as próteses foram mantidas em água destilada e termocicladas com variação de temperatura entre 5º-55º C. Para a verificação das tensões geradas pelas próteses parciais fixas em torno dos implantes foi realizada a análise por correlação de imagens digitais. Foram selecionados cinco modelos de cada um dos sistemas CAD/CAM e um antagonista e aplicada uma carga de 250 N, com velocidade de 0,1 mm/min, em máquina universal de ensaios. Para avaliação da resistência à fratura foi aplicada uma força perpendicular ao longo eixo da peça protética, no pôntico, até que devido à fratura não houvesse mais resistência. Após esse teste foi avaliado o relacionamento entre os componentes da prótese em microscópio eletrônico de varredura (MEV). A análise estatística mostrou que houve diferença significativa na adaptação pilar-implante dos molares entre os grupos Lava e ZirNeo, Lava e Controle (p=0,008). Para a desadaptação vertical e horizontal antes e após a prensagem e ciclagem não houve diferença significante (p>0,005). A desadaptação interna axial mostrou diferença significante antes e após para os molares dos grupos Lava e ZirNeo (p<0,001). A desadaptação interna oclusal mostrou diferença significante para os PM dos grupos TiNeo e Controle e para os molares dos grupos Lava e Zir Neo (p<0,005). Houve diferença significante de tensão na região cervical dos molares dos grupos ZirNeo e Lava (p=0,015) com maiores valores de tensão para o grupo Lava. O grupo TiNeo teve maior resistência à fratura que os demais (p=0,022). O relacionamento entre os componentes da prótese permaneceu favorável para todos os grupos. Os resultados deste trabalho permitem concluir que a prensagem da porcelana e a termociclagem mecânica não influenciou os resultados da desadaptação marginal e melhorou a desadaptação interna. O grupo usinado pelo sistema Neodent digital em zircônia teve maior concentração de tensão na região cervical podendo ter maior perda óssea nessa região. O grupo TiNeo foi o que mais resistiu à fratura. Entre fresar em zircônia pelo sistema Neodent digital ou Lava, o sistema Lava distribui melhor a tensão ao longo do implante, porém teve maiores valores de desadaptação interna. Entre fresar em titânio ou confeccionar a prótese pelo sistema convencional, melhor fresar. / Considering the growing aesthetic requirements, the development of zirconia and the increase of CAD/CAM technology, the aim of this study was to evaluate the marginal and internal fit, tensions in implants and fracture resistance after pressing porcelain and thermomechanical cycling in FPDs on implants with abutments and infrastructure in zirconia with two CAD/CAM systems (Neodent digital -Neodent and Lava - 3M ESPE) compared with the conventional method (n = 10). The marginal and internal fit was analyzed by a computerized microtomograph (microCT). Each prosthesis was scanned and the files were processed using the NRecon and CTAN software. Dataview program was used for the assessment of the measures. To carry out the thermomechanical cycling, prostheses were placed in mechanical fatigue machine for chewing and 120 N load was applied with a tip that simulates the antagonist occlusion simulating 2,000,000 cycles. During the test, the prostheses were kept in distilled water and thermocycled with temperatures between 5°-55° C. Digital image correlation analysis was performed to check the load transfer by implant-supported restoration. Five models were selected from each of the CAD/CAM systems and an antagonist and a load of 250 N was applied, with 0.1 mm/min speed using a universal testing machine. The fracture resistance was verified with force applied perpendicular to the long axis of the prosthesis, at pontic, until there were no more fracture resistance. After this test was evaluated the relationship between the components of the prosthesis in a scanning electron microscope (SEM). The statistical analysis showed significant difference in abutment-implant fit of molars between Lava and ZirNeo, Lava and control groups (p=.008). For vertical and horizontal fit there was no significant difference (p>.005) before and after pressing and thermomechanical cycling. The axial internal gap was significantly different before and after for molar ZirNeo groups (p<.001). The occlusal internal fit was significantly different to the PM of TiNeo and Control, and the molars of Lava and ZirNeo (p<.005). There were significant difference for tension in the cervical region of the molars of ZirNeo and Lava (p=.015) with higher values for the Lava group. TiNeo group had higher resistance to fracture than others (p=.022). The relationship between the prosthesis components remained positive for all groups. The results of this study showed that the pressing of porcelain and thermomechanical cycling did not influence the results of marginal gap and improved internal fit. The zirconia group machined by Neodent digital system had higher concentration of tension in the cervical and may have greater bone loss in this region. TiNeo group was the most resistant to fracture. Between the zirconia milling by Neodent digital or Lava system, the Lava system distributes better strain throughout the implant, but had greater internal fit values. Between milling titanium or fabricate the prosthesis by the conventional system, better milling.
24

Vergleichende in vitro Untersuchung von zwei vollkeramischen Systemen

Gozdowski, Stephan 02 April 2012 (has links)
Die hier vorliegende Dissertation beschreibt die vergleichenden Untersuchungen zweier Verfahren zur Herstellung vollkeramischen Zahnersatzes. Zur Bewertung der Praxistauglichkeit eines solchen Systems sind mehrere Untersuchungskriterien notwendig. Für einen klinischen Langzeiterfolg sind die marginale und okklusale Präzision von entscheidender Bedeutung. Aus betriebswirtschaftlicher und gesundheitspolitischer Sicht ist für den Zahnarzt aber auch der notwendige zeitliche Aufwand von elementarer Bedeutung. Das Ziel dieser in-vitro-Untersuchung war es, zwei vollkeramische Systeme hinsichtlich ihrer marginalen und okklusalen Präzision zu vergleichen. Zusätzlich wurde der verfahrensbedingte Zeitaufwand zur Herstellung einer vollkeramischen Restauration untersucht.:Inhaltsverzeichnis Seite 1. Einleitung -1- 1.2 Ziel der Untersuchung -3- 1.3 Klinische Relevanz -3- 2. “Marginal Fit of Heat-pressed vs CAD/CAM Processed -8- All-ceramic Onlays Using a Milling Unit Prototype” 3. “In vitro analysis of laboratory processed and CAD/CAM -16- generated occlusal onlay surfaces” 4. “A Comparison of the Fabrication Times of -20- All-ceramic Partial Crowns: Cerec 3D vs IPS Empress” 5. Zusammenfassung -32- 6. Literaturverzeichnis -38- 7. Erklärung -41- 8. Darstellung des wissenschaftlichen Werdegangs -42- 9. Lebenslauf -44- 10. Danksagung -46-

Page generated in 0.0434 seconds