Spelling suggestions: "subject:"espaçados"" "subject:"espaçador""
1 |
Retenção do aprendizado do uso de inalador dosimetrado com espaçador artesanal trinta dias após orientação sistemáticaSANTOS, Maria da Conceição Luna dos 31 January 2010 (has links)
Made available in DSpace on 2014-06-12T15:51:37Z (GMT). No. of bitstreams: 2
arquivo2887_1.pdf: 2055221 bytes, checksum: 8e9b2d1b128f019a2ecb4a9062109749 (MD5)
license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5)
Previous issue date: 2010 / A asma é um importante problema de saúde pública mundial, acometendo
indivíduos de todas as idades e raças, em todos os países. Trata-se de uma
doença inflamatória crônica, que quando não controlada, pode trazer
importantes limitações à vida cotidiana ou até mesmo ser fatal. A via inalatória
é a principal forma de administração de medicamentos para o tratamento da
asma, seja preventivo, seja no resgate das crises, sendo os corticóides e os
broncodilatadores as principais classes de drogas utilizadas. Esta dissertação
foi composta por duas partes; no artigo de revisão foram abordados aspectos
relacionados à inaloterapia tais como as propriedades farmacológicas das
drogas, a importância da via inalatória na administração de medicamentos
diretamente nas vias aéreas para o tratamento da asma, os mecanismos de
deposição dos aerossóis, processo de geração das partículas nos diversos
dispositivos inalatórios, a relação da inaloterapia e a asma e a importância dos
inaladores, sobretudo os espaçadores artesanais não valvulados (EANV). No
artigo original foi realizado um estudo de intervenção, do tipo antes e depois,
com 137 pacientes para avaliar a eficácia de uma sessão de orientação
sistemática em promover o uso correto dos inaladores dosimetrados acoplados
a espaçadores artesanais não valvulados (IDs/EANV) trinta dias após essa
orientação. Apesar dos EANV terem contribuído para que muitos pacientes
utilizassem corretamente os IDs/EANV, 64% dos pacientes os utilizava de
maneira errada, mesmo tendo demonstrado saber fazê-lo corretamente após o
treinamento, 30 dias antes. Os resultados mostram que este aprendizado se
perde em tempo relativamente curto e sugerem que é necessário revisar a
técnica a cada consulta
|
2 |
Estudo numérico experimental de treliças espaciais feitas com tubos de aço com ponta amassada e espaçadores de madeira para corrigir as excentricidades nos nós de ligação / Numerical experimental study of space trusses made of steel tubes with flatened ends wood spacers to correct excentricities in the connectionCasanova, Pablo Andrés Andrade 25 June 2015 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, 2015. / Submitted by Albânia Cézar de Melo (albania@bce.unb.br) on 2015-11-10T13:05:46Z
No. of bitstreams: 1
2015_PabloAndresAndradeCasanova.pdf: 10282622 bytes, checksum: 0484e4fff4199441308f8a1e533b54b0 (MD5) / Approved for entry into archive by Marília Freitas(marilia@bce.unb.br) on 2016-07-30T12:08:06Z (GMT) No. of bitstreams: 1
2015_PabloAndresAndradeCasanova.pdf: 10282622 bytes, checksum: 0484e4fff4199441308f8a1e533b54b0 (MD5) / Made available in DSpace on 2016-07-30T12:08:06Z (GMT). No. of bitstreams: 1
2015_PabloAndresAndradeCasanova.pdf: 10282622 bytes, checksum: 0484e4fff4199441308f8a1e533b54b0 (MD5) / As treliças espaciais feitas com tubos com pontas amassadas e conectadas por um único parafuso (conexão típica) são amplamente utilizadas no Brasil devido a sua fácil construção e economia com respeito às ligações com patente. Entretanto, a ligação típica é fraca devido à excentricidade e a diminuição da inércia no nó devido ao processo de amassamento do tubo. Em pesquisas anteriores, foi observado que ao se corrigir a excentricidade gerada pelos tubos convergentes no mesmo nó, usando espaçadores de aço, a treliça pode suportar mais carga consideravelmente. Entretanto, a utilização desses espaçadores de aço aumentava o custo e gerava carga de peso próprio adicional. Desta forma, o objetivo da presente pesquisa é substituir os espaçadores de aço por espaçadores feitos de madeira, que são mais econômicos e leves. Para se avaliar a melhoria na capacidade resistente da treliça, neste trabalho se fez um estudo numérico-experimental a fim de se examinar a viabilidade do uso da madeira como espaçador. No estudo numérico foi modelada uma treliça espacial tetraédrica tubular com base quadrada de 2m por 2m e altura de 0,7m usando-se para a análise numérica o software comercial em Elementos Finitos, ANSYS Workbench 14.5. Nas análises foi considerada uma geometria detalhada da treliça bem como o comportamento não linear físico e geométrico da treliça procurando-se desta forma se chegar a uma modelagem a mais próxima possível da realidade. No estudo experimental foram ensaiadas três treliças espaciais de secção tubular com ligação típica e com espaçadores de madeira Maçaranduba. Nestes testes, verificou-se que os espaçadores de madeira resistiram bem às cargas. Além disso, a capacidade de suporte da treliça resultou muito semelhante à capacidade das treliças anteriores usando espaçadores de aço. Os tipos de deformação (flambagem e deformações locais) que se apresentaram no modelo numérico e no ensaio experimental são bem semelhantes. Tais semelhanças nos resultados enfatiza que o modelo numérico prevê adequadamente o colapso e a deformada das treliças observadas nos ensaios experimentais. Portanto, conclui-se que os resultados mostram a viabilidade do uso de espaçadores como uma alternativa para substituir os espaçadores de aço em treliças com a vantagem de menor peso e custo. / Space trusses made of tubes with flattened ends connected with a trespassing bolt (typical connection) are widely used due to its easy construction and economy with respect to patented connections. However, the typical connection is weak due to the eccentricity and reduced momentum of inertia that exists at the nodes due to the flattening process. In previous studies, it was observed that when correcting the eccentricity generated by converging tubes at the same node, using steel spacers, the truss can support more load considerably. However, the use of such spacers made of steel increased the cost of production and generated additional dead load. Thus, the objective of the present research is to replace the steel spacers for spacers made of wood, which are more economical and lighter. To assess the improvement in the bearing capacity of the truss, this work applied a numerical and experimental approach to exam the feasibility of using wood spacer. In the numerical study, a tubular tetrahedral spatial lattice with square base 2m by 2m and 0.7m height was used. In the numerical analysis the commercial Finite Element software, ANSYS Workbench 14.5 was employed. The numerical analyses considered the detailed geometry of the truss as well as the non-linear behavior of the material and geometry trying to model the truss as close to reality as possible. In the experimental study, three trusses with typical connections and “Maçaranduba” wooden spacers were tested. In these tests, it was observed that the wood spacers withstood the loads. Moreover, the bearing capacity of the truss was very similar to bearing capacity of the previous trusses using steel spacers. The types of deformation (buckling and local deformations) shown in the numerical model and in the experimental test were very similar. This similarity in the results highlights that the numerical model adequately predicted the collapse and deformed shape of the trusses observed in the lab tests. Therefore, in conclusion: the results show that the use of wood spacers is feasible and an alternative to replace steel spacers in trusses with less weight and cost.
|
3 |
Coeficientes de atrito de subcanais e distribuição do escoamento em arranjos hexagonais de barras com espaçadores helicoidaisBloch, Mauro, Instituto de Engenharia Nuclear 02 1900 (has links)
Submitted by Marcele Costal de Castro (costalcastro@gmail.com) on 2017-12-14T11:47:51Z
No. of bitstreams: 1
MAURO BLOCH M.pdf: 3552948 bytes, checksum: ad50ca92629797db3b33ceeb109d315c (MD5) / Made available in DSpace on 2017-12-14T11:47:51Z (GMT). No. of bitstreams: 1
MAURO BLOCH M.pdf: 3552948 bytes, checksum: ad50ca92629797db3b33ceeb109d315c (MD5)
Previous issue date: 1983-02 / O núcleo de um reator rápido, tipo LMFBR, é composto de feixes hexagonais de barras de arranjo triangular com espaçadores helicoidais. Neste trabalho, foi feita uma análise hidráulica dos subcanais lateral e de canto, que juntamente com o interno, compõem o feixe. Foram realizadas medidas de queda * de pressão, vazão e temperatura para ó escoamento de água, nos dois tipos de subcanais, Isolados geometricamente. Desta forma, obteve-se, a variação do fator de atrito, como função do número de Reynolds, bem como a razão entre os fatores de distribuição do escoamento, para os subcanais lateral e de canto. Os parâmetros geométricos utilizados foram: diâmetro de barra 10,04 mm e 8,01 mm, passo axial 160 mm e 80 mm, faixa de número de Reynolds de 100 a 30.000.
|
4 |
Avaliação do conhecimento sobre o uso de inaladores dosimetrados entre profissionais de saúde de um hospital pediátrico / Evaluation of the knowledge of health professionals at a pediatric hospital regarding the use of metered-dose inhalersMuchão, Fabio Pereira 06 April 2009 (has links)
Existem evidências na literatura de que a administração de medicações, como corticosteróides inalatórios e broncodilatadores, utilizando inaladores pressurizados dosimetrados, é mais eficaz e segura do que com os nebulizadores convencionais. Entretanto, há evidências de que não só pacientes, mas também profissionais de saúde têm dificuldade no manejo dos inaladores pressurizados dosimetrados. A hipótese do presente estudo é que o conhecimento da técnica inalatória entre os profissionais da nossa Instituição é heterogêneo, sendo que não há informações sobre o nível deste conhecimento entre as diversas categorias profissionais. OBJETIVOS: Avaliar o conhecimento prático e teórico de profissionais da área médica, de enfermagem e fisioterapia sobre a utilização do inalador dosimetrado através de testes padronizados. MÉTODOS: Avaliações teóricas e práticas sobre o conhecimento do uso de inaladores pressurizados dosimetrados foram realizadas com médicos, fisioterapeutas, enfermeiras e auxiliares de enfermagem, atribuindo-se uma nota de 0 a 10 para cada avaliação. Calcularam-se as medianas das notas obtidas pelos profissionais de cada categoria, as questões com maiores e menores índices de erros e feita a comparação descritiva do desempenho das diversas categorias profissionais. Após as avaliações, instrução verbal e escrita sobre a utilização correta dos dispositivos foi fornecida a todos os participantes. A análise estatística foi feita através do método de Kruskal-Wallis de comparação de medianas. Também foi realizada a análise através de regressão logística múltipla seqüencial. RESULTADOS: foram avaliados 30 médicos residentes ou estagiários da pediatria, 23 médicos assistentes, 29 fisioterapeutas, 33 enfermeiras e 31 auxiliares de enfermagem, em um total de146 profissionais. Não foram entrevistados residentes ou assistentes do grupo de Pneumologia. Os médicos residentes, fisioterapeutas e os médicos assistentes obtiveram desempenho significativamente superior que os enfermeiros e auxiliares de enfermagem. Apenas os médicos residentes obtiveram mediana superior a seis. As questões práticas com maiores índices de erros foram as relativas à limpeza do espaçador. Questões relativas à agitação do inalador antes do uso e à limpeza da cavidade oral após a sua utilização também obtiveram alto índice de erros. A questão teórica mais errada foi a respeito do tempo necessário entre dois jatos em aplicações sucessivas do inalador pressurizado dosimetrado. CONCLUSÕES: O conhecimento teórico-prático dos profissionais de saúde da Instituição a respeito do uso de inaladores pressurizados dosimetrados é heterogêneo. Os médicos residentes, fisioterapeutas e médicos assistentes obtiveram desempenho significativamente melhor que os enfermeiros e auxiliares de enfermagem sendo que estes últimos estão diretamente envolvidos na aplicação prática destes dispositivos na rotina hospitalar. / There are data in the literature indicating that the administration of medications such as inhaled corticosteroids and bronchodilators, using metered-dose inhalers, is more effective and safer than its dispensation by conventional nebulizers. However, there is evidence that not only patients but also health care professionals have difficulty in dealing with pressurized dose inhalers. The hypothesis of the present study is that the knowledge of inhalation techniques among health professionals of our Institution is heterogeneous, and there is no information about this knowledge among the diverse categories of professionals. OBJECTIVE: To assess the practical and theoretical knowledge of medical professionals, nursing and physiotherapy on the use of metereddose inhalers by standardized testing. METHODS: Practical and written tests on the use of metered-dose inhalers were applied to physicians, physical therapists, nurses and nursing assistants. A score from 0 to 10 was assigned to each evaluation. Median scores were calculated for each professional category. Questions with higher and lower correct values were identified, and a descriptive comparison was made regarding the performance of the diverse professional categories. Following the examination, oral and written instructions on the correct use of the devices were provided for all participants. Statistical analysis was performed using the Kruskal-Wallis method for comparison of medians. A sequential logistic multiple regression analysis was also performed. RESULTS: A total of 146 professionals were assessed, including 30 fellows in pediatrics, 23 attending physicians, 29 physical therapists, 33 nurses and 31 nursing assistants. Fellows or attending physicians of the Pediatric Pulmonology Unit were not included in the study. Fellows, physical therapists and attending physicians performed significantly better than did nurses and nursing assistants. Only fellows had a median score greater than six. On the practical tests for infants and toddlers, the step most often missed was that related to cleaning the spacer. On practical tests, the steps related to shaking the inhaler and cleaning the mouth also presented high error indices. On the written tests, the question most often answered incorrectly was that related to the waiting time between puffs. CONCLUSIONS: The theoretical and practical knowledge of health professionals of our Institution on the use of metered-dose inhalers is heterogeneous. The performance of fellows, physical therapists and attending physicians was significantly better than that of nurses and nursing assistants who are directly involved in the practical application of these devices in the hospital routine.
|
5 |
Avaliação do conhecimento sobre o uso de inaladores dosimetrados entre profissionais de saúde de um hospital pediátrico / Evaluation of the knowledge of health professionals at a pediatric hospital regarding the use of metered-dose inhalersFabio Pereira Muchão 06 April 2009 (has links)
Existem evidências na literatura de que a administração de medicações, como corticosteróides inalatórios e broncodilatadores, utilizando inaladores pressurizados dosimetrados, é mais eficaz e segura do que com os nebulizadores convencionais. Entretanto, há evidências de que não só pacientes, mas também profissionais de saúde têm dificuldade no manejo dos inaladores pressurizados dosimetrados. A hipótese do presente estudo é que o conhecimento da técnica inalatória entre os profissionais da nossa Instituição é heterogêneo, sendo que não há informações sobre o nível deste conhecimento entre as diversas categorias profissionais. OBJETIVOS: Avaliar o conhecimento prático e teórico de profissionais da área médica, de enfermagem e fisioterapia sobre a utilização do inalador dosimetrado através de testes padronizados. MÉTODOS: Avaliações teóricas e práticas sobre o conhecimento do uso de inaladores pressurizados dosimetrados foram realizadas com médicos, fisioterapeutas, enfermeiras e auxiliares de enfermagem, atribuindo-se uma nota de 0 a 10 para cada avaliação. Calcularam-se as medianas das notas obtidas pelos profissionais de cada categoria, as questões com maiores e menores índices de erros e feita a comparação descritiva do desempenho das diversas categorias profissionais. Após as avaliações, instrução verbal e escrita sobre a utilização correta dos dispositivos foi fornecida a todos os participantes. A análise estatística foi feita através do método de Kruskal-Wallis de comparação de medianas. Também foi realizada a análise através de regressão logística múltipla seqüencial. RESULTADOS: foram avaliados 30 médicos residentes ou estagiários da pediatria, 23 médicos assistentes, 29 fisioterapeutas, 33 enfermeiras e 31 auxiliares de enfermagem, em um total de146 profissionais. Não foram entrevistados residentes ou assistentes do grupo de Pneumologia. Os médicos residentes, fisioterapeutas e os médicos assistentes obtiveram desempenho significativamente superior que os enfermeiros e auxiliares de enfermagem. Apenas os médicos residentes obtiveram mediana superior a seis. As questões práticas com maiores índices de erros foram as relativas à limpeza do espaçador. Questões relativas à agitação do inalador antes do uso e à limpeza da cavidade oral após a sua utilização também obtiveram alto índice de erros. A questão teórica mais errada foi a respeito do tempo necessário entre dois jatos em aplicações sucessivas do inalador pressurizado dosimetrado. CONCLUSÕES: O conhecimento teórico-prático dos profissionais de saúde da Instituição a respeito do uso de inaladores pressurizados dosimetrados é heterogêneo. Os médicos residentes, fisioterapeutas e médicos assistentes obtiveram desempenho significativamente melhor que os enfermeiros e auxiliares de enfermagem sendo que estes últimos estão diretamente envolvidos na aplicação prática destes dispositivos na rotina hospitalar. / There are data in the literature indicating that the administration of medications such as inhaled corticosteroids and bronchodilators, using metered-dose inhalers, is more effective and safer than its dispensation by conventional nebulizers. However, there is evidence that not only patients but also health care professionals have difficulty in dealing with pressurized dose inhalers. The hypothesis of the present study is that the knowledge of inhalation techniques among health professionals of our Institution is heterogeneous, and there is no information about this knowledge among the diverse categories of professionals. OBJECTIVE: To assess the practical and theoretical knowledge of medical professionals, nursing and physiotherapy on the use of metereddose inhalers by standardized testing. METHODS: Practical and written tests on the use of metered-dose inhalers were applied to physicians, physical therapists, nurses and nursing assistants. A score from 0 to 10 was assigned to each evaluation. Median scores were calculated for each professional category. Questions with higher and lower correct values were identified, and a descriptive comparison was made regarding the performance of the diverse professional categories. Following the examination, oral and written instructions on the correct use of the devices were provided for all participants. Statistical analysis was performed using the Kruskal-Wallis method for comparison of medians. A sequential logistic multiple regression analysis was also performed. RESULTS: A total of 146 professionals were assessed, including 30 fellows in pediatrics, 23 attending physicians, 29 physical therapists, 33 nurses and 31 nursing assistants. Fellows or attending physicians of the Pediatric Pulmonology Unit were not included in the study. Fellows, physical therapists and attending physicians performed significantly better than did nurses and nursing assistants. Only fellows had a median score greater than six. On the practical tests for infants and toddlers, the step most often missed was that related to cleaning the spacer. On practical tests, the steps related to shaking the inhaler and cleaning the mouth also presented high error indices. On the written tests, the question most often answered incorrectly was that related to the waiting time between puffs. CONCLUSIONS: The theoretical and practical knowledge of health professionals of our Institution on the use of metered-dose inhalers is heterogeneous. The performance of fellows, physical therapists and attending physicians was significantly better than that of nurses and nursing assistants who are directly involved in the practical application of these devices in the hospital routine.
|
6 |
Avaliação da adaptação marginal de copings metálicos fundidos em ligas de níquel-cromo, níquel-cromo-berílio e em titânio comercialmente puro em função da aplicação de espaçadores / Evaluation of the use of die spacer over the marginal fit of casting copings of Ni-Cr, Ni-Cr-Be and commercially pure TitaniumNatércia Carreira Soriani 01 February 2008 (has links)
O objetivo do trabalho foi avaliar o efeito do uso de espaçadores na adaptação marginal de copings confeccionados em ligas de Ni-Cr (Verabond II) (VB II) e Ni-Cr-Be (Verabond) (VB) e Titânio cp (Tritan) (Ti-cp) fundidos pela técnica de cera perdida. A partir de uma matriz metálica, foram obtidos 135 troquéis de gesso resinado tipo IV para confecção dos padrões de cera nas seguintes condições: sem a presença de espaçador (G0), com uma camada de espaçador (G1) e com duas camadas de espaçador (G2), com quinze repetições para cada grupo. Foi realizado o enceramento de cada troquel e os padrões de cera foram incluídos em revestimento adequado para cada material. Em cada anel de fundição foram incluídos 3 padrões de cera, sendo cada um correspondente a cada condição. Cada coping, adaptado à matriz metálica por meio de um dispositivo padronizador da pressão de assentamento, foi levado ao Microscópio Óptico para aferição das medidas da desadaptação marginal. Os dados obtidos (µm) foram submetidos à análise estatística (ANOVA) e teste de Tukey (p<0.05). Para a condição material, a liga VB (118,73) não apresentou diferença estatisticamente significante em relação à liga VB II (93,40), sendo que estas apresentaram diferença estatisticamente significante em relação ao Ti-cp (168,35). Em relação ao fator espaçador, houve diferença estatisticamente significante entre as três condições (G0=177,31; G1=121,51 e G2=81,66). Com base nos dados obtidos pelo presente estudo, pode-se afirmar que a presença de duas camadas de espaçador propicia menor desadaptação marginal. / The purpose of the study was to evaluate the effect of using die spacers on the marginal fit of Ni Cr (Verabond II) (VB II) and Ni-Cr-Be (Verabond) (VB) alloys and commercially pure Titanium (Tritan) (Ti-cp) casting copings by the lost wax technique. Using a metal master die, 135 Resin Added Extra Hard Type IV Stone were obtained for the fabrication of wax patterns in the following conditions: without die spacer (G0), with one die spacer layer (G1); and with two die spacer layers (G2), with fifteen repetitions for each group. Each stone die was waxed and the wax patterns were invested as recommended by the manufacturer. Three wax patterns were embedded in each casting ring, each corresponding to a condition. Each coping, seated to the metal matrix by a Seating Pressure Standardizing Device (SPSD), was taken to the Optic Microscope for the measurement of marginal discrepancy. The obtained data (µm) were submitted to statistical analysis (ANOVA) and Tukey test (p<0.05). There was not statistically significant difference among the materials VB II (93,40) and VB (118,73), and there was statistically significant different to Ti-cp (168,35) . In terms of the die spacer, there was a statistically significant difference among the three conditions (G0=177,31; G1=121,51 e G2=81,66). It was concluded that with two die spacer layers there is less marginal discrepancy.
|
7 |
Avaliação da adaptação marginal de copings metálicos fundidos em ligas de níquel-cromo, níquel-cromo-berílio e em titânio comercialmente puro em função da aplicação de espaçadores / Evaluation of the use of die spacer over the marginal fit of casting copings of Ni-Cr, Ni-Cr-Be and commercially pure TitaniumSoriani, Natércia Carreira 01 February 2008 (has links)
O objetivo do trabalho foi avaliar o efeito do uso de espaçadores na adaptação marginal de copings confeccionados em ligas de Ni-Cr (Verabond II) (VB II) e Ni-Cr-Be (Verabond) (VB) e Titânio cp (Tritan) (Ti-cp) fundidos pela técnica de cera perdida. A partir de uma matriz metálica, foram obtidos 135 troquéis de gesso resinado tipo IV para confecção dos padrões de cera nas seguintes condições: sem a presença de espaçador (G0), com uma camada de espaçador (G1) e com duas camadas de espaçador (G2), com quinze repetições para cada grupo. Foi realizado o enceramento de cada troquel e os padrões de cera foram incluídos em revestimento adequado para cada material. Em cada anel de fundição foram incluídos 3 padrões de cera, sendo cada um correspondente a cada condição. Cada coping, adaptado à matriz metálica por meio de um dispositivo padronizador da pressão de assentamento, foi levado ao Microscópio Óptico para aferição das medidas da desadaptação marginal. Os dados obtidos (µm) foram submetidos à análise estatística (ANOVA) e teste de Tukey (p<0.05). Para a condição material, a liga VB (118,73) não apresentou diferença estatisticamente significante em relação à liga VB II (93,40), sendo que estas apresentaram diferença estatisticamente significante em relação ao Ti-cp (168,35). Em relação ao fator espaçador, houve diferença estatisticamente significante entre as três condições (G0=177,31; G1=121,51 e G2=81,66). Com base nos dados obtidos pelo presente estudo, pode-se afirmar que a presença de duas camadas de espaçador propicia menor desadaptação marginal. / The purpose of the study was to evaluate the effect of using die spacers on the marginal fit of Ni Cr (Verabond II) (VB II) and Ni-Cr-Be (Verabond) (VB) alloys and commercially pure Titanium (Tritan) (Ti-cp) casting copings by the lost wax technique. Using a metal master die, 135 Resin Added Extra Hard Type IV Stone were obtained for the fabrication of wax patterns in the following conditions: without die spacer (G0), with one die spacer layer (G1); and with two die spacer layers (G2), with fifteen repetitions for each group. Each stone die was waxed and the wax patterns were invested as recommended by the manufacturer. Three wax patterns were embedded in each casting ring, each corresponding to a condition. Each coping, seated to the metal matrix by a Seating Pressure Standardizing Device (SPSD), was taken to the Optic Microscope for the measurement of marginal discrepancy. The obtained data (µm) were submitted to statistical analysis (ANOVA) and Tukey test (p<0.05). There was not statistically significant difference among the materials VB II (93,40) and VB (118,73), and there was statistically significant different to Ti-cp (168,35) . In terms of the die spacer, there was a statistically significant difference among the three conditions (G0=177,31; G1=121,51 e G2=81,66). It was concluded that with two die spacer layers there is less marginal discrepancy.
|
8 |
Estudo dos fatores interferentes na adaptação marginal de próteses confeccionadas em titânio comercialmente puro e ligas alternativas / Study of determining factors for the marginal fit of prosthesis made of commercially pure titanium and alternative alloysSoriani, Natércia Carreira 08 April 2011 (has links)
O desajuste de copings obtidos por fundição por cera perdida está sujeita à vários fatores tais como: contração de fundição do metal, expansão do revestimento, uso de espaçadores, entre outros. O objetivo do estudo foi avaliar o desajuste marginal pré e pós cimentação de copings obtidos com três ligas de metais básicos - Ni-Cr-Be (VB), Ni-Cr (V2) e Co-Cr (KE) fundidos a partir de dois revestimentos - Termocast (TE) e Microfine (MI) e Titânio comercialmente puro (TR) fundido com dois revestimentos - Rematitan Plus (RP) e Rematitan Ultra (RU), nas condições E0, sem espaçador, E1, com uma camada de espaçador e E2, com duas camadas de espaçador. A partir de uma matriz metálica, foram obtidos 240 copings, sendo 10 para cada combinação metal-revestimento-espaçador. Foi utilizado Microscópio Óptico para determinação do desajuste nas condições pré e pós cimentação, efetuada com cimento de fosfato de zinco. Foi realizado teste de tração pós cimentação para determinação da carga de remoção dos copings da combinação KE-MI. Foram realizados ensaios dilatométricos para a definição dos coeficientes de expansão térmico linear dos metais e dos revestimentos, determinação da expansão de presa dos revestimentos, além de ensaio para determinação da variação dimensional das fundições e análises de microscopia eletrônica de varredura (MEV). Os dados de desajuste marginal foram analisados estatisticamente pelos testes Anova e Student-Newman-Keulsa que revelaram significância estatística (0,05) para os fatores isolados. Para os metais, os valores de desajuste (μm) foram V2 (85) = VB (89) < KE (119) < TR (171) e para os revestimentos, MI (68) < TE (128) < RP (153) < RU (188). Para o espaçador os desajustes foram E2 (76) < E1 (125) < E0 (147). Os menores valores de desajuste pós cimentação foram obtidos pelas combinações: VB-MI-E2 (44), V2-MI-E2 (47), VB-MI-E1 (52), VB-MI-E0 (55), TR-RU-E2 (67), V2-MI-E1(70), V2-TE-E2 (77), V2-MI-E0 (86), VB-TE-E2 (103), todas as demais combinações tiveram valores acima de 120 μm, adotado como referência clinicamente aceitável. Houve diferença significante para as cargas de remoção entre as condições E2 (49 Kgf) < E1 (74 Kgf) < E0 (102 Kgf). Os valores de expansão de presa foram: TE (1,05%), MI (0,88%), RP (0,19%) e RU (0,02%). Para o ensaio dilatométrico, os valores de contração dos metais foram: KE (0,270%), V2 (0,262%), VB (0,256%) e TR (0,160%). Para os revestimentos, houve diferença significante, entre MI (0,74%) e RU (-1,63%). A análise da variação dimensional revelou diferença significante para os metais: V2 (0,08%) ≥ VB (-0,12%) ≥ KE (-0,21%) ≥ R (-0,85%) e para os revestimentos: MI (0,09%) > TE (-0,26%) = RP (-0,50%) > RU (-1,19%). Os revestimentos MI e RU apresentaram micro estrutura mais refinada, contendo cristais mais homogêneos e menos porosidade que os revestimentos RP e TE. Com base nos dados analisados, é válido afirmar que, embora a utilização de revestimentos com boas propriedades dilatométricas facilite a confecção de copings com ajuste marginal adequado, a utilização de espaçadores pode ser indispensável para obtenção de resultados clínicos satisfatórios. / The marginal fit of copings made by lost-wax casting are subject to different variation factors, such as contraction of molten metal, investment thermal expansion, die spacer use and others. This study aimed to evaluate the marginal adaptation of copings before and after cementation, obtained with three basic alloys - Ni-Cr-Be (VB), Ni-Cr (V2) and Co-Cr (KE), melted with two investments - Termocast (TE) and Microfine (MI) - and commercially pure titanium (TR) melted with Rematitan Plus (RP) and Rematitan Ultra (RU), in the conditions: E0 (without die spacer), E1 (one die spacer layer) and E2 (two die spacer layers). From a metal matrix, 240 copings were obtained, 10 for each combination metal-investment-spacer. An optical microscope was used to determine the misfit before and after the cementation with zinc phosphate cement. A tensile strength test was carried out after the cementation in order to determine the remotion load. Dilatometric tests were used to calculate the linear thermal expansion coefficients of metals and investments, to determine the setting expansion of the investments and to determine the dimensional variation as well. After the tests, the data were analyzed statistically. The analysis of variance for the marginal adaptation showed statistical significance (0.05) for all variation factors. For the metals, the misfit, in μm, was: V2 (85) = VB (89) < KE (119) < TR (171); and for investments, MI (68) < TE (128) < RP (153) < RU (188). The misfit for factor die spacer was: E2 (76) < E1 (125) < E0 (147). Having accepted the value of 120 μm as a reference limit of clinically acceptable results, the lowest misfit values for different combinations after cementation were: VB-MI-E2 (44), V2-MI-E2 (47), VB-MI-E1 (52), VB-MI-E0 (55), RU-TR-E2 (67 μm), V2-MI-E1 (70), E2-V2-TE (77), V2-MI-E0 (86), VB-TE-E2 (103). All the other combinations had values above 120 μm. There was a significant difference for tensile strength under the conditions E2 (49 Kgf), E1 (74 Kgf) and E0 (102 kgf). The setting expansion values were: TE (1.05%), MI (0.88%), RP (0.19%) and RU (0.02%). According to the dilatometer test, the values of contraction for the metals were: KE (0.27%), V2 (0.262%), VB (0.256%) and TR (0.16%), and for the investments: MI (0.74%) and RU (-1.63%). The analysis of variance revealed significant differences for metals dimensional variation: V2 (0.08%) ≥ VB (-0.12%) ≥ KE (-0.21%) ≥ TR (-0.85%) and investments: MI (0.09%) > TE (-0.26%) = RP (-0.50%) > RU (-1.19%). In conclusion, the use of investments with good dilatometric properties improves the marginal fit of the copings, but the die spacer use may be essential for obtaining satisfactory clinical results.
|
9 |
Estudo dos fatores interferentes na adaptação marginal de próteses confeccionadas em titânio comercialmente puro e ligas alternativas / Study of determining factors for the marginal fit of prosthesis made of commercially pure titanium and alternative alloysNatércia Carreira Soriani 08 April 2011 (has links)
O desajuste de copings obtidos por fundição por cera perdida está sujeita à vários fatores tais como: contração de fundição do metal, expansão do revestimento, uso de espaçadores, entre outros. O objetivo do estudo foi avaliar o desajuste marginal pré e pós cimentação de copings obtidos com três ligas de metais básicos - Ni-Cr-Be (VB), Ni-Cr (V2) e Co-Cr (KE) fundidos a partir de dois revestimentos - Termocast (TE) e Microfine (MI) e Titânio comercialmente puro (TR) fundido com dois revestimentos - Rematitan Plus (RP) e Rematitan Ultra (RU), nas condições E0, sem espaçador, E1, com uma camada de espaçador e E2, com duas camadas de espaçador. A partir de uma matriz metálica, foram obtidos 240 copings, sendo 10 para cada combinação metal-revestimento-espaçador. Foi utilizado Microscópio Óptico para determinação do desajuste nas condições pré e pós cimentação, efetuada com cimento de fosfato de zinco. Foi realizado teste de tração pós cimentação para determinação da carga de remoção dos copings da combinação KE-MI. Foram realizados ensaios dilatométricos para a definição dos coeficientes de expansão térmico linear dos metais e dos revestimentos, determinação da expansão de presa dos revestimentos, além de ensaio para determinação da variação dimensional das fundições e análises de microscopia eletrônica de varredura (MEV). Os dados de desajuste marginal foram analisados estatisticamente pelos testes Anova e Student-Newman-Keulsa que revelaram significância estatística (0,05) para os fatores isolados. Para os metais, os valores de desajuste (μm) foram V2 (85) = VB (89) < KE (119) < TR (171) e para os revestimentos, MI (68) < TE (128) < RP (153) < RU (188). Para o espaçador os desajustes foram E2 (76) < E1 (125) < E0 (147). Os menores valores de desajuste pós cimentação foram obtidos pelas combinações: VB-MI-E2 (44), V2-MI-E2 (47), VB-MI-E1 (52), VB-MI-E0 (55), TR-RU-E2 (67), V2-MI-E1(70), V2-TE-E2 (77), V2-MI-E0 (86), VB-TE-E2 (103), todas as demais combinações tiveram valores acima de 120 μm, adotado como referência clinicamente aceitável. Houve diferença significante para as cargas de remoção entre as condições E2 (49 Kgf) < E1 (74 Kgf) < E0 (102 Kgf). Os valores de expansão de presa foram: TE (1,05%), MI (0,88%), RP (0,19%) e RU (0,02%). Para o ensaio dilatométrico, os valores de contração dos metais foram: KE (0,270%), V2 (0,262%), VB (0,256%) e TR (0,160%). Para os revestimentos, houve diferença significante, entre MI (0,74%) e RU (-1,63%). A análise da variação dimensional revelou diferença significante para os metais: V2 (0,08%) ≥ VB (-0,12%) ≥ KE (-0,21%) ≥ R (-0,85%) e para os revestimentos: MI (0,09%) > TE (-0,26%) = RP (-0,50%) > RU (-1,19%). Os revestimentos MI e RU apresentaram micro estrutura mais refinada, contendo cristais mais homogêneos e menos porosidade que os revestimentos RP e TE. Com base nos dados analisados, é válido afirmar que, embora a utilização de revestimentos com boas propriedades dilatométricas facilite a confecção de copings com ajuste marginal adequado, a utilização de espaçadores pode ser indispensável para obtenção de resultados clínicos satisfatórios. / The marginal fit of copings made by lost-wax casting are subject to different variation factors, such as contraction of molten metal, investment thermal expansion, die spacer use and others. This study aimed to evaluate the marginal adaptation of copings before and after cementation, obtained with three basic alloys - Ni-Cr-Be (VB), Ni-Cr (V2) and Co-Cr (KE), melted with two investments - Termocast (TE) and Microfine (MI) - and commercially pure titanium (TR) melted with Rematitan Plus (RP) and Rematitan Ultra (RU), in the conditions: E0 (without die spacer), E1 (one die spacer layer) and E2 (two die spacer layers). From a metal matrix, 240 copings were obtained, 10 for each combination metal-investment-spacer. An optical microscope was used to determine the misfit before and after the cementation with zinc phosphate cement. A tensile strength test was carried out after the cementation in order to determine the remotion load. Dilatometric tests were used to calculate the linear thermal expansion coefficients of metals and investments, to determine the setting expansion of the investments and to determine the dimensional variation as well. After the tests, the data were analyzed statistically. The analysis of variance for the marginal adaptation showed statistical significance (0.05) for all variation factors. For the metals, the misfit, in μm, was: V2 (85) = VB (89) < KE (119) < TR (171); and for investments, MI (68) < TE (128) < RP (153) < RU (188). The misfit for factor die spacer was: E2 (76) < E1 (125) < E0 (147). Having accepted the value of 120 μm as a reference limit of clinically acceptable results, the lowest misfit values for different combinations after cementation were: VB-MI-E2 (44), V2-MI-E2 (47), VB-MI-E1 (52), VB-MI-E0 (55), RU-TR-E2 (67 μm), V2-MI-E1 (70), E2-V2-TE (77), V2-MI-E0 (86), VB-TE-E2 (103). All the other combinations had values above 120 μm. There was a significant difference for tensile strength under the conditions E2 (49 Kgf), E1 (74 Kgf) and E0 (102 kgf). The setting expansion values were: TE (1.05%), MI (0.88%), RP (0.19%) and RU (0.02%). According to the dilatometer test, the values of contraction for the metals were: KE (0.27%), V2 (0.262%), VB (0.256%) and TR (0.16%), and for the investments: MI (0.74%) and RU (-1.63%). The analysis of variance revealed significant differences for metals dimensional variation: V2 (0.08%) ≥ VB (-0.12%) ≥ KE (-0.21%) ≥ TR (-0.85%) and investments: MI (0.09%) > TE (-0.26%) = RP (-0.50%) > RU (-1.19%). In conclusion, the use of investments with good dilatometric properties improves the marginal fit of the copings, but the die spacer use may be essential for obtaining satisfactory clinical results.
|
Page generated in 0.0553 seconds