• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 37
  • Tagged with
  • 37
  • 37
  • 37
  • 32
  • 18
  • 11
  • 11
  • 10
  • 9
  • 9
  • 7
  • 7
  • 7
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Contribuição ao projeto de bomba centrifuga de sangue

Motta, Gastão Dias 07 August 1991 (has links)
Orientador: Antonio Celso Fonseca de Arruda / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-07-14T00:30:18Z (GMT). No. of bitstreams: 1 Motta_GastaoDias_M.pdf: 5283386 bytes, checksum: 30a6f3b20fbf536c6b10ef0f70cb9e20 (MD5) Previous issue date: 1991 / Resumo: Este trabalho tem como objetivo basico contribuir para o desenvolvimento de uma bomba centrifuga de sangue funcionando sob o principio do arrasto viscoso entre uma ou mais superficies lisas rotativas e o sangue. A sua elaboração pode ser dividida numa parte experimental e numa parte teorica, as quais foram desenvolvidas de maneira simultanea mas absolutamente independentes entre...Observação: O resumo, na íntegra poderá ser visualizado no texto completo da tese digital / Abstract: The basic aim of this research is to contribute to the development of a centrifugal blood pump based on the viscous shear-force between one or more rotating smooth surfaces and the blood. This investigation has both an experimental part and a theoretical analysis, which have been simultaneously developed as absolutelly independent works...Note: The complete abstract is available with the full electronic digital thesis or dissertations / Mestrado / Mestre em Engenharia Mecânica
2

Analisador de desfibriladores/cardioversores

Nohama, Percy 31 January 1992 (has links)
Orientador: Maria Adelia Collier Farias / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica / Made available in DSpace on 2018-07-14T01:52:04Z (GMT). No. of bitstreams: 1 Nohama_Percy_M.pdf: 20926581 bytes, checksum: feaa301892b4c8844808a93bf5f336a7 (MD5) Previous issue date: 1992 / Resumo: A manutenção efetiva de equipamentos médicos, tais como desfibriladores e cardioversores, requer manutenção preventiva e corretiva que, em muitos casos, precisa ser realizada próxima à unidade hospitalar onde os equipamentos são utilizados. Desenvolveu-se um Analisador de desfibriladores/cardioversores analógico-digital, que atende aos requisitos de um instrumento de calibração, a um custo relativamente baixo. O Analisador é portátil e auto-suficiente (alimentado por baterias comuns). Cuidados especiais foram tomados para evitar perigos de choque elétrico (saída para osciloscópio isolada opticamente) ... Observação: O resumo, na íntegra, poderá ser visualizado no texto completo da tese digital / Abstract: Effective maintenance of medical devices, such as defibrillators and cardioverters, requires preventive maintenance and repair, which should be carried out in manu instances near the hospital unit where the devices are being used. It was developed an analogical-digital defibrillator/cardioverter analyzer, which fulfills the requirements of a calibrating equipment, at a relatively low cost. The analyzer is powered by ordinary batteries, it is self-sufficient, portable, and special care was taken to avoid shock hazards (optically isolated output to oscilloscope) ... Note: The complete abstract is available with the full electronic digital thesis or dissertations / Mestrado / Mestre em Engenharia Elétrica
3

Estudo do processo de analise de referencia aplicado a engenharia clinica e metodologia de validação de indicadores de referencia

Cardoso, Geice Bolognani 24 July 2018 (has links)
Orientador: Saide Jorge Calil / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-07-24T23:51:56Z (GMT). No. of bitstreams: 1 Cardoso_GeiceBolognani_M.pdf: 9278805 bytes, checksum: 47d9fc83d519635f5c5a2eb87e6979a1 (MD5) Previous issue date: 1999 / Resumo: O estudo e adaptações de processos de análise de referência e principalmente de indicadores apropriados para este fim visa fornecer métodos contínuos e racionais para o direcionamento dos departamentos de engenharia clínica às melhorias contínuas nas suas atividades. O objetivo principal desta dissertação é apresentar uma metodologia para auxiliar gerentes de equipamentos médico-hospitalares a visualizar oportunidades ou necessidades de mudança dentro do seu departamento com o uso de indicadores de referência validados. A validação de indicadores para uso no processo de análise de referência proposta é uma ferramenta que pode ser incorporada as atividades de um departamento de engenharia clínica, utilizando-se muitas vezes de indicadores de uso corrente, sendo estes validados, no próprio departamento. As etapas principais da metodologia são: (1) seleção e adaptação de um método de análise de referência; (2) seleção dos indicadores e (3) validação e cálculo dos indicadores de referência. Visando uma análise global da atividade de manutenção, o grupo de indicadores foi selecionado com a seguinte premissa: possuir a maior abrangência sobre a qualidade do serviço manutenção de equipamentos médico hospitalares sem decorrer em redundância. Este grupo pré-selecionado foi aplicado a um estudo de caso da metodologia de validação apresentada. A ferramenta de validação se mostrou, através do estudo de caso, plenamente aplicável a realidade do nosso país / Abstract: The study and adaptation of the processof reference analysis and mainly of the appropriate indicators to this aim intend to give continuous and rational methods to the management of clinical engineering departaments towards continuous improvements in their medical-hospitalar equipments managers to visualize opportunities and needs of change in their departments with the use of validated reference indicators. The validation of the indicators for utilization in the proposed process of reference analysis is a toei that can be incorpored to the activities of a clinical engineering department, often taking advantage of currently used indicators, then being these indicators valitated in the department itself. The main stages of the metodology are: (1) selection and adaptation of a reference analysis process; (2) selection of the indicators; and (3) validation and calculus of the reference indicators. Looking at a global analysis of the support activity, the group of the refemce indicators was selected with the follow premiss: having the biggest embracement over the quality os the service of medical-hospitalar equipments support, without incurring in redundance. With this pre-seleted group was chosen for a case study of the metodology of validation. The toei for validation of indicators for reference analysis resulted, by the case study, completely applicable to the reality of our country / Mestrado / Mestre em Engenharia Elétrica
4

Desfibrilador cardiaco microprocessado para uso clinico e em pesquisa

Cortes Gomez, Hernan 24 September 1993 (has links)
Orientador: Sergio Santos Muhlen / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica / Made available in DSpace on 2018-07-25T18:51:40Z (GMT). No. of bitstreams: 1 CortesGomez_Hernan_M.pdf: 6658816 bytes, checksum: ec8cfade1b6facd438b77d4a6905a3c4 (MD5) Previous issue date: 1993 / Resumo: Os desfibriladores/cardioversores devem fornecer informações das condições do paciente e da descarga desfibrilatória ao operador, para que este possa respectivamente dimensionar a descarga desfibrilatória e analisar o resultado da mesma. Desenvolveu-se um desfibrilador/cardioversor cardíaco comandado por um microcontrolador. O aparelho é portátil e alimentado por bateria. Tem como principais características a medição da impedância entre as pás e o cálculo da energia entregue. Armazena de 1 até 40J com passo de 1J / Abstract: The defibrillators/cardioverters must give information about defibrillatory discharge and patient conditions to the operator, so the operator can respectively dimensionate the discharge and analise the results. lt was developed a cardiac microcontrolled defibrillator/cardioverter. The device is portable and battery powered. Its maÍllcaracteristics are the measurement of the impedance between the paddles and the ability to calculate the delivered energy. The stored energy can be selected from 1 to 40J with a step of 1J / Mestrado / Mestre em Engenharia Elétrica
5

Sistema para simulação de ECG/arritmias cardiacas para ensino e treinamento de pessoal

Ribeiro, Antonio de Assis Bento 12 December 1991 (has links)
Orientador: Maria Adelia Collier Farias / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica / Made available in DSpace on 2018-07-15T23:59:56Z (GMT). No. of bitstreams: 1 Ribeiro_AntoniodeAssisBento_M.pdf: 6186676 bytes, checksum: aa7c093863f85d2494304e406ffc7f1d (MD5) Previous issue date: 1991 / Resumo: O ensino do reconhecimento e classificação dos diversos padrões anormais do eletrocardiograma é uma tarefa que geralmente demanda tempo considerável, em parte devido a falta de instrumentos adequados. Portanto, para suprir a carência de simuladores de ECG para fins didáticos, no Brasil, desenvolveu-se um programa em linguagem C, SIMULA, para computador pessoal compatível com a linha IBM-PC-XT que permite visualização dinâmica no monitor de vídeo de qualquer arritmia cardíaca. Os ECG's das arritmias estão gravados em disco rígido e podem ser obtidos de qualquer uma das seguintes fontes: fita magnética, mesa digitalizadora, e teclado. O sistema permite interação com o usuário, facilitando e acelerando a aprendizagem do tema / Abstract: Not informed. / Mestrado / Mestre em Engenharia Elétrica
6

Estudo preliminar para contrução de um oclusor ativo implantavel para colostomias

Paula, Josue Bruginski de 03 September 1992 (has links)
Orientador: Alberto Cliquet Junior / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica / Made available in DSpace on 2018-07-17T09:45:35Z (GMT). No. of bitstreams: 1 Paula_JosueBruginskide_M.pdf: 8874692 bytes, checksum: bfda81c0184773cdbf106c5a2fb76672 (MD5) Previous issue date: 1992 / Resumo: A inferior qualidade de vida dos pacientes portadores de colostomia foi a mola propulsora deste trabalho e o desenvolvimento de um oclusor eficaz é uma maneira de tentar modificar este quadro. Após realizar uma revisão bibliográfica das várias técnicas tentadas na tratamento de incontinências (fecais e vesicais) nos últimos dez anos, decidimos investigar a possibilidade de utilização de força eletromagnética/mecânica (EMM) para promover um estado continente em colostomias. Devido às grandes dificuIdades em caracterizar e modelar as propriedades mecânicas da musculatura lisa, em especial dos intestinos, optamos pela determinação das características e propriedades necessárias às peças componentes de um esfíncter artificial que, utilizando força eletromagnética/mecânica, imitasse a ação esfincteriana. Com este fim, realizaríamos um trabalho experimental com cólon isolado de 26 cães adultos com mais de 15 kg. Uma fita plástica de 0,9 cm de largura foi colocada em torno da porção distal dos cólons e seu perímetro reduzido a passos de 0,25 cm. Em 10 experimentos a força de tração necessária para deslocar a fita foi monitorada com o uso de uma célula de carga. Os cólons variaram entre 17 e 57 cm de comprimento e 5,4 e 8,5 cm de perímetro, e obtivemos continência para gases a uma pressão intraluminal acima de 80 mmHg em todos os experimentos quando era atingido um perímetro final entre 3,7 e 4,7 cm. Após os testes, não foi observada nenhuma lesão macroscópica na área de constricção. O maior deslocamento da fita foi de 4, 2 cm e a força de tração necessár ia para deslocá-la foi inferior a 50 N. Estes resultados tornam promissora a construção de um oclusor para colostomias ativo e implantável utilizando força EMM e imitando a ação esfincteriana / Abstract: The low quality of life of the colostomates was the starting point of this work, and one of the ways to change this situation i s the development of an efficient colostomy ocluder. A review of the last ten years wor ks on technics available in order to improve faecal and vesical continence has shown that the use of eletromagnetic/mechanical (EMM) power has not been under investigation. As we know, modelling of the smooth muscles mechanical properties remains as a trial to biomedical scientists, in particular the mechanical behavior of the intestinal muscle. This work looks at the characteristics needed to the components of an artificial sphincter that works with EMM power and reproduces the natural sphincter action. The experimental work was done with isolated colon of 26 mongrel dogs. A 0 9 cm width plastic band was set around the terminal stoma and it's perimeter was reduced in steps of 0.255 cm. In 10 experiments the traction force needed to pull the band was measued with a force transducer. The colons varied from 17 to 57 centimeters lenght and 5.4 to 8.5 centimeters perimeter, and all of them became continent for an intraluminal gas pressure over 80 mmHg when a final perimeter between 3.7 and 4.7 was reached / Mestrado / Mestre em Engenharia Elétrica
7

Obtenção e processamento de sinais de eletrocardiografia de alta resolução

Huallpa, Belisario Nina 21 December 1992 (has links)
Orientadores : Eduardo Tavares Costa , Amauri Lopes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica / Made available in DSpace on 2018-07-18T05:18:50Z (GMT). No. of bitstreams: 1 Huallpa_BelisarioNina_M.pdf: 4106001 bytes, checksum: 1e2d6d1ab2cbeeaa22a729892cbbe15a (MD5) Previous issue date: 1992 / Resumo: No presente trabalho, sinais de Eletrocardiografia de Alta Resolução (ECG-AR) são obtidos, processados e então analisados os chamados Potenciais Tardios Ventriculares (PTV), que resultam da despolarização defasada (tardia) do tecido cardíaco ventricular. Os PTV aparecem na fase final da despolarização ventricular, são de pequena amplitude e apresentam componentes de alta freqüência quando comparados os demais potenciais de despolarização ventricular. Como consequência, não é possível observá-los usando ferramentas convencionais, já que, os potenciais devido à despolarização ventricular e ao ruído (muscular, dos eletrodos e da instrumentação utilizada) mascaram os PTV. Portanto, é necessário utilizar métodos que permitam filtrar o ruído e permitam verificar a existência ou não de PTV. Para filtrar o ruído e para obter o sinal de ECG-AR, utiliza-se a técnica de promediação. Para a detecção e análise dos PTV, foram especialmente implementadas ferramentas de processamento de sinais: 1) a Transformada de Fourier de Curta Duração (TFCD)i e 2) a Distribuição de Wigner (DW). Estas duas técnicas permitem a análise de sinais de ECG-AR no duplo domínio tempo-frequência, procurando-se estabelecer critérios de positividade da existência ou não dos PTV. Para validar e parametrizar os PTV será necessário realizar muitos exames em indivíduos normais e naqueles suspeitos de serem propensos a sofrer arritmias ventriculares / Abstract: In the present work, High Resolution Electrocardiography (HR-ECG) signals are obtained, processed and then ventricular late potentials which result from the late depolarization of the ventricule are analysed. Late potentials are generally present at the end of ventricular depolarization, presenting small amplitude and high frequency components when compared to ventricular depolarization signals. Therefore, it is not possible to observe those signals using conventional instrumentation due to ventricular activation and noise (from muscle contraction, electrodes and instrumentation). So, it is necessary to use methods which permit to improve signal-to-noise ratio of the ECG and to verify the existence of the late potentials. The signal averaging method is used to obtain high resolution ECG. In order to detect and analyse the late potentials two signal processing techniques were implemented: 1) the Short Time Fourier Transform; and 2) the Wigner Distribution. These techniques allow the analysis in both time and frequency domains simultaneously and they have been used to try to detect late potentials. Normal patients as well as patients at risk of developing ventricular arrythmias shall be tested using the methods implemented in order to validate them / Mestrado / Mestre em Engenharia Elétrica
8

Automação e controle da caixa de pressão negativa de membros inferiores

Cambraia, Rodrigo Reckziegel January 2014 (has links)
Made available in DSpace on 2014-08-22T02:01:12Z (GMT). No. of bitstreams: 1 000460448-Texto+Completo-0.pdf: 5951570 bytes, checksum: afed14c2ca9f2963cc42ed8d5fb7baaa (MD5) Previous issue date: 2014 / The use of equipment "lower body negative pressure box" (LBNP) is a instrument of great importance to the scientific community health sciences. Initially used for simulation of orthostatic stress in space agencies studies on the physiological performance, today it has a range of applications to be study. In mid-2002, a LBNP Box was developed at the Center for Microgravity Laboratory, but it became outdate and out of use. This work was done to modernize pneumatic, electrical, electronic systems and the application interface. The realized retrofit enables the equipment for research use in the area of Aerospace Medicine on orthostatic intolerance of the cardiovascular system. Auniversal process controller with PID control technique was used with a classical tuning control proposed in the first method of Ziegler and Nichols. / O uso do equipamento “lowerbody negative pressureBox” (LBNP- caixa de pressão negativa) é de grande importância para a comunidade científica das ciências da saúde. Inicialmente utilizado para simulação de estresse ortostático em estudos sobre o comportamento fisiológico pelas agências espaciais, hoje já tem sua gama de aplicações para estudo. Em meados de 2002 uma LBNP foi desenvolvida no Laboratório do Centro de Microgravidade, porém ela ficou desatualizada e inoperante. O presente foi realizado para modernizar ossistemas pneumático, elétrico, eletrônico assim como o aplicativo de interface. O “retrofit” realizado deixou o equipamento em condições para o uso em pesquisas na área de Medicina Aeroespacial sobre intolerância ortostática do sistema cardiovascular. Um controlador universal de processos com controle do tipo PID utilizando técnica de controle clássico de sintonia proposto no primeiro método de Ziegler e Nichols.
9

Desenvolvimento de uma plataforma virtual em telecirurgia como ferramenta complementar de ensino

Cardoso, Ricardo Bertoglio January 2014 (has links)
Made available in DSpace on 2014-11-18T01:01:19Z (GMT). No. of bitstreams: 1 000462672-Texto+Completo-0.pdf: 8146289 bytes, checksum: b06948bf980943025484977e7b5c207b (MD5) Previous issue date: 2014 / The constant evolution of technology enables a wider access to and a more global production of digital texts, audios, images, and videos. The internet, which greatly enhances this sharing capability, has been constantly growing in coverage and in data transfer capacity, therefore allowing virtual communication to simulate real-life interaction. The combination of these elements in education, especially in health education, led to large improvements in the capacity to illustrate it rather than just explain it. These technologies have great potential to improve teaching methods, which sometimes are inefficient or have high maintenance costs. In the theoretical learning of surgical procedures, for example, the presence of students in the operating room does not necessarily provide them with a better understanding of the technique used by the surgeon, as he or she may not be able to get close enough to see the area where the procedure is being performed. This problem stems from the limited space available in the room, as well as from the care for the patient’s wellbeing, which should not be compromised as result of the amount of observers in the room. Aware of these elements and of the existing demand for improvement of teaching tools in the university, this project had as its main aim the development of a telesurgery system for health education. In order to accomplish this goal, three systems were developed: a photograph camera positioning equipment (eSurg-Arm) to assist image acquisition in the operating room; a specification of equipment and video formats to enable image acquisition and transmission (eSurg-Video), and a health education web platform (eSurg-Web). The eSurg-Arm successfully developed the design, the simulation, the prototyping, and the testing of hardware, software, and mechanical devices and parts. The development of eSurg-Video called for the analysis of different video compression and transmission technologies. The making of eSurg-Web established the parameters (i. e. functionalities and information) to build a distance education web-learning tool, as well as to develop a functional prototype. Each of these systems accomplished different results. The eSurg-Arm built and validated three systems: movement control and instrumentation, articulated arm and Pan/Tilt/Roll/Zoom. The eSurg-Video enabled the synchronous and asynchronous video streaming of different resolution videos. The eSurg-Web accomplished the design of multiple information blocks, which enabled the development of an educational web platform. In short, the eSurg project successfully positioned an image acquisition system and granted access to a web platform that allow professors and students to interact with surgical multimedia content from medical/chirurgical procedures performed at the São Lucas Hospital – PUCRS. / A constante evolução da tecnologia vem permitindo um acesso cada vez mais amplo e uma produção cada vez mais global de textos, áudios, imagens e vídeos. A Internet cresce constantemente em alcance e capacidade de transferência de dados, tornando possível a comunicação virtual em um nível que já imita a realidade. A combinação desses elementos na educação, e mais especificamente na educação em saúde, tem resultado em grandes avanços na capacidade de professores de ilustrar o conteúdo ao invés de apenas explica-lo. Dessa forma, essas ferramentas vêm ao encontro da necessidade de melhoria de métodos de ensino, muitas vezes pouco eficientes e de custo elevado para sua implementação e manutenção. No aprendizado teórico sobre técnicas cirúrgicas, por exemplo, a presença de acadêmicos junto ao paciente não garante a visualização do procedimento, devido ao espaço limitado e à importância de que a quantidade de observadores não prejudique o decorrer da cirurgia. Atento a esses diferentes elementos e às demandas existentes na universidade, esse projeto teve como objetivo o desenvolvimento de um sistema de Telecirurgia como ferramenta educacional em saúde. Para tanto, foram desenvolvidos: um equipamento para posicionamento de um sistema de aquisição de imagens em sala cirúrgica (eSurg-Arm); uma especificação de equipamentos e formatos para aquisição e transmissão de imagens (eSurg-Video); e uma aplicação web em linguagem de alto nível como ferramenta educacional em saúde (eSurg-Web). O eSurg-Arm contemplou o design, a simulação, a prototipação e a realização de ensaios de hardware, software e de mecanismos e peças mecânicas. O eSurg-Video foi responsável por analisar diferentes tecnologias de compressão e transmissão de vídeo. O eSurg-Web realizou a definição das funcionalidades e informações necessárias para a criação de uma plataforma web para ensino a distância, tendo feito sua prototipação. Cada uma das etapas de desenvolvimento obteve resultados específicos. O eSurg-Arm resultou na construção e validação de três sistemas, o primeiro de controle e instrumentação de movimento, o segundo de suporte articulado e o terceiro de Pan/Tilt/Roll/Zoom. O eSurg-Video resultou na capacidade de oferecer diferentes resoluções de vídeo, bem como transmiti-los de forma síncrona ou assíncrona. O eSurg-Web teve como resultado o design de múltiplos conjuntos de informações que permitiu a prototipação de uma aplicação web. O eSurg teve sucesso em permitir o posicionamento de sistema de aquisição de imagens, por meio do eSurg-Arm, e em desenvolver uma ferramenta educacional em saúde, que possibilita o acesso interativo de docentes e discentes ao conteúdo de cirurgias realizadas no Hospital São Lucas da PUCRS. O sistema de aquisição e transmissão de vídeos definido pelo projeto se mostrou adequado à prática cirúrgica nos ensaios e testes realizados.
10

Estudo da estratégia de harmonização da quantificação do SUV em imagens de PET/CT

Fischer, Andréia Caroline Fischer da Silveira January 2014 (has links)
Made available in DSpace on 2014-12-06T01:01:32Z (GMT). No. of bitstreams: 1 000462943-Texto+Completo-0.pdf: 4086036 bytes, checksum: 8b6abefa3b76b3bc43dbf4ca084a593b (MD5) Previous issue date: 2014 / In clinical practice, PET/CT images are often analyzed qualitatively by visual comparison of tumor lesions and normal tissues uptake; and semi-quantitatively by means of a parameter called SUV (Standardized Uptake Value). To ensure that longitudinal studies acquired on different scanners are interchangeable, and information of quantification is comparable, it is necessary to establish a strategy to harmonize the quantification of SUV. The aim of this study is to evaluate the strategy to harmonize the quantification of PET/CT images, performed with different scanner models and manufacturers. For this purpose, a survey of the technical characteristics of equipment and acquisition protocols of clinical images of different services of PET/CT in the state of Rio Grande do Sul was conducted. For each scanner, the accuracy of SUV quantification, and the Recovery Coefficient (RC) curves were determined, using the reconstruction parameters clinically relevant and available. From these data, harmonized performance specifications among the evaluated scanners were identified, as well as the algorithm that produces, for each one, the most accurate quantification. Finally, the most appropriate reconstruction parameters to harmonize the SUV quantification in each scanner, either regionally or internationally were identified. It was found that the RC values of the analyzed scanners proved to be overestimated by up to 38%, particularly for objects larger than 17mm. These results demonstrate the need for further optimization, through the reconstruction parameters modification, and even the change of the reconstruction algorithm used in each scanner. It was observed that there is a decoupling between the best image for PET/CT qualitative analysis and the best image for quantification studies. Thus, the choice of reconstruction method should be tied to the purpose of the PET/CT study in question, since the same reconstruction algorithm is not adequate, in one scanner, for qualitative and quantitative assessments in different scopes. We concluded that the harmonization strategy of the SUV quantification presented in this paper was effective in reducing the variability of small structures quantification. However, for the comparison of SUV quantification between different scanners and institutions, it is essential that, in addition to the harmonization of quantification, the standardization of the methodology of patient preparation is maintained, in order to minimize the SUV variability due to biological factors. / Na rotina clínica, imagens de PET/CT, costumam ser analisadas qualitativamente, mediante a comparação visual entre a captação nos tecidos hipercaptantes e nos tecidos normais; e, semiquantitativamente, por meio de um parâmetro denominado SUV (do inglês Standardized Uptake Value). Para garantir que estudos longitudinais adquiridos em distintos equipamentos sejam intercambiáveis e informações de quantificação sejam comparáveis, torna-se necessário o estabelecimento de uma estratégia de harmonização da quantificação do SUV. O objetivo geral deste estudo é avaliar uma estratégia de harmonização da quantificação de imagens de PET/CT, realizada com equipamentos de diferentes modelos e fabricantes. Para tanto, foi realizado um levantamento das características técnicas do equipamento e dos protocolos de aquisição das imagens clínicas de distintos serviços de PET/CT do estado do Rio Grande do Sul. Para cada equipamento, foram determinadas a acurácia da quantificação do SUV e as curvas de Coeficiente de Recuperação (RC, do inglês Recovery Coefficient), utilizando os parâmetros de reconstrução clinicamente disponíveis e relevantes. A partir desses dados, foram identificadas as especificações de desempenho harmonizáveis dentre os equipamentos avaliados, assim como o algoritmo que produz, em cada equipamento, a quantificação mais acurada. Finalmente, foram identificados os parâmetros de reconstrução mais adequados à harmonização da quantificação do SUV em cada equipamento, em âmbito regional e internacional. Constatou-se que os valores de RC dos equipamentos analisados mostraram-se superestimados em até 38%, particularmente para objetos de dimensões maiores do que 17 mm. Estes resultados mostram a necessidade de uma otimização, mediante a modificação dos parâmetros de reconstrução utilizados e até mesmo da mudança do algoritmo de reconstrução utilizado em cada equipamento. Observou-se que existe uma dissociação entre a melhor imagem para análise qualitativa e a melhor imagem para quantificação dos estudos de PET/CT. Assim, a escolha do método de reconstrução deve estar atrelada à finalidade do estudo de PET/CT em questão, visto que um mesmo algoritmo de reconstrução não se mostra adequado, em um único equipamento, às avaliações qualitativas e quantitativas, em diferentes âmbitos. Conclui-se que a estratégia de harmonização da quantificação do SUV apresentada neste trabalho mostrou-se eficaz na redução da variabilidade da quantificação de pequenas estruturas. Entretanto, para que a quantificação do SUV possa ser comparada entre diferentes equipamentos e instituições, é fundamental que, além da harmonização da quantificação, seja mantida a padronização da metodologia de preparo do paciente, visando minimizar a variabilidade atribuída ao SUV decorrente de fatores biológicos.

Page generated in 0.1628 seconds