• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 37
  • Tagged with
  • 37
  • 37
  • 37
  • 32
  • 18
  • 11
  • 11
  • 10
  • 9
  • 9
  • 7
  • 7
  • 7
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Investiga??o pr?-cl?nica para desfibriladores externos

Vieira, Amanda Assun??o 23 January 2013 (has links)
Made available in DSpace on 2015-04-14T13:56:27Z (GMT). No. of bitstreams: 1 446996.pdf: 3699710 bytes, checksum: 04ecb9d6e5b88b2a83d57907908fa28e (MD5) Previous issue date: 2013-01-23 / There is consensus that the physical characterizations of medical devices defibrillation, especially those obtained by mechanical testing and electrical safety tests, are a critical step in transforming innovative concepts into reliable products for use in humans. However, considering that the chest ventricular defibrillation applied by an electric shock is not necessarily an innocuous procedure, since studies have shown as much damage as morphological functional impairment of the heart caused by successive shocks, the information obtained by testing pre -clinical tests allow to relate the safety and efficacy of electric shock in experimental animals to determine any undesirable side effects in normal use and assess whether they are at risk due to the intended device?s performance.Investigations into the cardioversion efficacy in response to induced ventricular fibrillation and macroscopic changes and biochemical changes that occur in porcine hearts were performed after capacitive discharge truncated exponential shock applied defibrillator produced nationally and another reference "golden standard" international market leader . . It was concluded that the defibrillator prototype when applied with energy 100J demonstrated better efficacy in terminating ventricular fibrillation and had less injury than the defibrillator reference with the same energy, making it suitable for the insertion of the national and international market. This study will help to raise the standard of technology and increase the supply of qualified health equipment produced in Brazil, replacing and / or decreasing imports and providing a secure next generation equipment / ? consensual que as caracteriza??es f?sicas de equipamentos m?dicos de desfibrila??o, em especial aquelas obtidas por meio de ensaios mec?nicos e testes de seguran?a el?trica, constituem uma etapa critica na transforma??o de conceitos inovadores em produtos confi?veis para o uso em seres humanos. Entretanto, considerando que a desfibrila??o ventricular aplicada no peito por meio de um choque el?trico n?o necessariamente ? um procedimento in?cuo, uma vez que estudos t?m demonstrado tanto dano morfol?gico quanto defici?ncia funcional do cora??o causado por sucessivos choques, as informa??es obtidas por meio de testes pr?-cl?nicos permitem relacionar a seguran?a e efic?cia do choque el?trico em animais experimentais de modo a determinar quaisquer efeitos secund?rios indesej?veis em condi??es normais de utiliza??o e avaliar se estes constituem riscos em fun??o do funcionamento previs?vel do dispositivo.Investiga??es sobre a efic?cia da cardiovers?o em resposta ? fibrila??o ventricular induzida e mudan?as macrosc?picas e bioqu?micas que ocorrem nos cora??es de su?nos foram realizadas ap?s choque de descarga capacitiva exponencial truncada aplicado de um prot?tipo de desfibrilador produzido nacionalmente e outro refer?ncia padr?o ouro l?der de mercado internacional. Concluiu-se que o desfibrilador prot?tipo quando aplicado com energia 100J demonstrou melhor efic?cia na rescis?o da fibrila??o ventricular e apresentou menor inj?ria que o desfibrilador de refer?ncia com a mesma energia, tornando-do apto para a inser??o do mercado nacional e internacional. Este estudo ajudar? a elevar o padr?o tecnol?gico e a ampliar a oferta qualificada de equipamentos para a sa?de produzidos no Brasil, substituindo e/ou diminuindo importa??es e oferecendo um dispositivo seguro de ?ltima gera??o.
22

Automa??o e controle da caixa de press?o negativa de membros inferiores

Cambraia, Rodrigo Reckziegel 16 January 2014 (has links)
Made available in DSpace on 2015-04-14T13:56:32Z (GMT). No. of bitstreams: 1 460448.pdf: 5951570 bytes, checksum: afed14c2ca9f2963cc42ed8d5fb7baaa (MD5) Previous issue date: 2014-01-16 / The use of equipment "lower body negative pressure box" (LBNP) is a instrument of great importance to the scientific community health sciences. Initially used for simulation of orthostatic stress in space agencies studies on the physiological performance, today it has a range of applications to be study. In mid-2002, a LBNP Box was developed at the Center for Microgravity Laboratory, but it became outdate and out of use.This work was done to modernize pneumatic, electrical, electronic systems and the application interface. The realized retrofit enables the equipment for research use in the area of Aerospace Medicine on orthostatic intolerance of the cardiovascular system. Auniversal process controller with PID control technique was used with a classical tuning control proposed in the first method of Ziegler and Nichols. / O uso do equipamento lowerbody negative pressureBox (LBNP- caixa de press?o negativa) ? de grande import?ncia para a comunidade cient?fica das ci?ncias da sa?de. Inicialmente utilizado para simula??o de estresse ortost?tico em estudos sobre o comportamento fisiol?gico pelas ag?ncias espaciais, hoje j? tem sua gama de aplica??es para estudo. Em meados de 2002 uma LBNP foi desenvolvida no Laborat?rio do Centro de Microgravidade, por?m ela ficou desatualizada e inoperante. O presente foi realizado para modernizar ossistemas pneum?tico, el?trico, eletr?nico assim como o aplicativo de interface. O retrofit realizado deixou o equipamento em condi??es para o uso em pesquisas na ?rea de Medicina Aeroespacial sobre intoler?ncia ortost?tica do sistema cardiovascular. Um controlador universal de processos com controle do tipo PID utilizando t?cnica de controle cl?ssico de sintonia proposto no primeiro m?todo de Ziegler e Nichols.
23

Estudo da estrat?gia de harmoniza??o da quantifica??o do SUV em imagens de PET/CT

Fischer, Andr?ia Caroline Fischer da Silveira 25 August 2014 (has links)
Made available in DSpace on 2015-04-14T13:56:33Z (GMT). No. of bitstreams: 1 462943.pdf: 4086036 bytes, checksum: 8b6abefa3b76b3bc43dbf4ca084a593b (MD5) Previous issue date: 2014-08-25 / In clinical practice, PET/CT images are often analyzed qualitatively by visual comparison of tumor lesions and normal tissues uptake; and semi-quantitatively by means of a parameter called SUV (Standardized Uptake Value). To ensure that longitudinal studies acquired on different scanners are interchangeable, and information of quantification is comparable, it is necessary to establish a strategy to harmonize the quantification of SUV. The aim of this study is to evaluate the strategy to harmonize the quantification of PET/CT images, performed with different scanner models and manufacturers. For this purpose, a survey of the technical characteristics of equipment and acquisition protocols of clinical images of different services of PET/CT in the state of Rio Grande do Sul was conducted. For each scanner, the accuracy of SUV quantification, and the Recovery Coefficient (RC) curves were determined, using the reconstruction parameters clinically relevant and available. From these data, harmonized performance specifications among the evaluated scanners were identified, as well as the algorithm that produces, for each one, the most accurate quantification. Finally, the most appropriate reconstruction parameters to harmonize the SUV quantification in each scanner, either regionally or internationally were identified. It was found that the RC values of the analyzed scanners proved to be overestimated by up to 38%, particularly for objects larger than 17mm. These results demonstrate the need for further optimization, through the reconstruction parameters modification, and even the change of the reconstruction algorithm used in each scanner. It was observed that there is a decoupling between the best image for PET/CT qualitative analysis and the best image for quantification studies. Thus, the choice of reconstruction method should be tied to the purpose of the PET/CT study in question, since the same reconstruction algorithm is not adequate, in one scanner, for qualitative and quantitative assessments in different scopes. We concluded that the harmonization strategy of the SUV quantification presented in this paper was effective in reducing the variability of small structures quantification. However, for the comparison of SUV quantification between different scanners and institutions, it is essential that, in addition to the harmonization of quantification, the standardization of the methodology of patient preparation is maintained, in order to minimize the SUV variability due to biological factors. / Na rotina cl?nica, imagens de PET/CT, costumam ser analisadas qualitativamente, mediante a compara??o visual entre a capta??o nos tecidos hipercaptantes e nos tecidos normais; e, semiquantitativamente, por meio de um par?metro denominado SUV (do ingl?s Standardized Uptake Value). Para garantir que estudos longitudinais adquiridos em distintos equipamentos sejam intercambi?veis e informa??es de quantifica??o sejam compar?veis, torna-se necess?rio o estabelecimento de uma estrat?gia de harmoniza??o da quantifica??o do SUV. O objetivo geral deste estudo ? avaliar uma estrat?gia de harmoniza??o da quantifica??o de imagens de PET/CT, realizada com equipamentos de diferentes modelos e fabricantes. Para tanto, foi realizado um levantamento das caracter?sticas t?cnicas do equipamento e dos protocolos de aquisi??o das imagens cl?nicas de distintos servi?os de PET/CT do estado do Rio Grande do Sul. Para cada equipamento, foram determinadas a acur?cia da quantifica??o do SUV e as curvas de Coeficiente de Recupera??o (RC, do ingl?s Recovery Coefficient), utilizando os par?metros de reconstru??o clinicamente dispon?veis e relevantes. A partir desses dados, foram identificadas as especifica??es de desempenho harmoniz?veis dentre os equipamentos avaliados, assim como o algoritmo que produz, em cada equipamento, a quantifica??o mais acurada. Finalmente, foram identificados os par?metros de reconstru??o mais adequados ? harmoniza??o da quantifica??o do SUV em cada equipamento, em ?mbito regional e internacional. Constatou-se que os valores de RC dos equipamentos analisados mostraram-se superestimados em at? 38%, particularmente para objetos de dimens?es maiores do que 17 mm. Estes resultados mostram a necessidade de uma otimiza??o, mediante a modifica??o dos par?metros de reconstru??o utilizados e at? mesmo da mudan?a do algoritmo de reconstru??o utilizado em cada equipamento. Observou-se que existe uma dissocia??o entre a melhor imagem para an?lise qualitativa e a melhor imagem para quantifica??o dos estudos de PET/CT. Assim, a escolha do m?todo de reconstru??o deve estar atrelada ? finalidade do estudo de PET/CT em quest?o, visto que um mesmo algoritmo de reconstru??o n?o se mostra adequado, em um ?nico equipamento, ?s avalia??es qualitativas e quantitativas, em diferentes ?mbitos. Conclui-se que a estrat?gia de harmoniza??o da quantifica??o do SUV apresentada neste trabalho mostrou-se eficaz na redu??o da variabilidade da quantifica??o de pequenas estruturas. Entretanto, para que a quantifica??o do SUV possa ser comparada entre diferentes equipamentos e institui??es, ? fundamental que, al?m da harmoniza??o da quantifica??o, seja mantida a padroniza??o da metodologia de preparo do paciente, visando minimizar a variabilidade atribu?da ao SUV decorrente de fatores biol?gicos.
24

Estudo e desenvolvimento de algoritmos para o reconhecimento de arritmias card?acas

Scolari, Diogo 10 August 2007 (has links)
Made available in DSpace on 2015-04-14T13:56:40Z (GMT). No. of bitstreams: 1 396423.pdf: 3058753 bytes, checksum: a4035eb0df593d854258c168ae594b28 (MD5) Previous issue date: 2007-08-10 / O presente trabalho tem por objetivo o estudo de algoritmos para o reconhecimento de arritmias card?acas. Para tanto, fez-se uma an?lise detalhada de dois algoritmos: HMM (Hidden Markov Model) e rede neural artificial do tipo RBF (Radial Basis Function), com a finalidade de reconhecer tr?s arritmias e o ritmo normal. As arritmias que foram utilizadas na pesquisa s?o: a Fibrila??o Atrial, a Taquicardia Ventricular e a Fibrila??o Ventricular. Tais arritmias foram selecionadas pela necessidade de desfibrila??o el?trica imediata na Taquicardia Ventricular e na Fibrila??o Ventricular e pelo fato da Fibrila??o Atrial ser a arritmia de maior incid?ncia na popula??o mundial. A necessidade de reconhecimento de arritmias pode ser vista em equipamentos DEA (Desfibriladores Externos Autom?ticos), utilizados para reconhecer e reverter a parada card?aca em locais fora de ambientes hospitalares. Estes equipamentos est?o sendo cada vez mais utilizados em v?rios pa?ses, como uma tentativa de diminuir o ?ndice de mortalidade. Primeiramente, foi feito um estudo te?rico sobre o cora??o, analisando as caracter?sticas de cada tipo de arritmia, a fim de poder identific?-las. Os pacientes foram selecionados no banco de dados de sinais biol?gicos, PhysioNet, para coleta de dados. Ap?s isso, foi feita uma an?lise te?rica detalhada dos sistemas de reconhecimento e em seguida, passou-se a gerar resultados a partir da compara??o entre os algoritmos e suas precis?es. Para atingir tais resultados, foi elaborada uma metodologia espec?fica de pesquisa. Ao final, foi poss?vel constatar que ambos algoritmos apresentam bom desempenho no reconhecimento das arritmias card?acas, bem como tamb?m foi poss?vel expor as caracter?sticas de desempenho de cada um dos sistemas
25

Instrumento de quantificação de movimentos de cabeça durante a avaliação de equilíbrio

Bregolin, Alexandre Dal Pizzol January 2013 (has links)
Made available in DSpace on 2013-12-11T01:01:49Z (GMT). No. of bitstreams: 1 000452831-Texto+Completo-0.pdf: 4042565 bytes, checksum: 5767bd96616a703ddf72b745e82d59b2 (MD5) Previous issue date: 2013 / This thesis describes the development of an instrument in the analysis and research of human balance. The instrument operates by providing data quantifying the selective head movements performed during measurement of the vestibular-ocular reflex (VOR). The VOR acts to stabilize the eye, to ensure a clear view during head movements. One of the techniques used in the evaluation of the vestibular system aims to observe the VOR in response to selective movements of the head. The algorithm developed for this study uses digital signal processing of three-dimensional data acquired by a sensor Kinect for Windows from Microsoft, and the detection of colored marks affixed to the quantification device of VOR in predetermined locations and with specific distances between the marks. The developed application allows the acquisition and display, graphically and synchronized, of the acquired data during the quantification of the stimuli used during the measurement of VOR. These graphs are corresponding to the three possible directions of rotation of the head where the VOR responds: horizontal (yaw), vertical (pitch) and torsional (roll). The application was developed with the C# programming language. Tests to evaluate the robustness and accuracy of the instrument were conducted through a device developed in this thesis, which performs mechanically, by means of a servomotor controlled movements, the movement of the marks. These movements were programmed to simulate the selective movements of head at different amplitudes and velocities. / Este trabalho apresenta o desenvolvimento de um instrumento de auxilio à análise e pesquisa do equilíbrio humano. O instrumento atua fornecendo dados da quantificação dos movimentos seletivos de cabeça exercidos durante a medição do reflexo vestíbulo-ocular (RVO). O RVO atua na estabilização do olhar para assegurar uma visão clara durante os movimentos da cabeça. Uma das técnicas utilizadas na avaliação do sistema vestibular visa observar o RVO em resposta a movimentos seletivos da cabeça. O algoritmo desenvolvido para este trabalho utiliza o processamento digital de dados tridimensionais adquiridos através de um sensor Kinect for Windows da Microsoft, e a detecção de marcas coloridas afixadas no dispositivo de quantificação do RVO em locais pré-determinados e com distâncias específicas entre as marcas. O aplicativo desenvolvido permite a aquisição e exibição, de forma gráfica e sincronizada, dos dados adquiridos durante a quantificação dos estímulos utilizados durante a medição do RVO. Estes gráficos são correspondentes aos três possíveis sentidos de rotação de cabeça aos quais o RVO responde: horizontal (yaw), vertical (pitch) e de torção (roll). O aplicativo foi desenvolvido com a linguagem de programação C#. Os testes para avaliar a robustez e precisão do instrumento foram realizados através de um dispositivo desenvolvido nesta tese, que desempenha de forma mecânica, através de movimentos controlados de um servomotor, o movimento das marcas. Estes movimentos foram programados de forma a simular os movimentos seletivos de cabeça em diferentes amplitudes e velocidades.
26

Sistema móvel de digitalização e monitoramento de parâmetros cardíacos com transmissão wireless

Rocha, Murilo Fraga da January 2007 (has links)
Made available in DSpace on 2013-08-07T18:53:07Z (GMT). No. of bitstreams: 1 000396311-Texto+Parcial-0.pdf: 54521 bytes, checksum: a23db9685133cfe5ee7b3228b7fdabe8 (MD5) Previous issue date: 2007 / People who search for medical assistance in hospitals face several problems such as lack of vacancy, high costs, infection risks, adaptation to a new environment and to a new diet, improductivity feeling, and deprivation from work. The aim of this work was to develop a mobile system that remotely monitors biological signals of pacients. Such device is part of a telemedicine system that intends to reduce hospital admissions and to minimize costs. This work describes the development of a mobile system for acquisition, processing and telemonitoration. It can improve the quality of life of the pacients by giving them mobility similiar to their daily routine. The system is composed of a portable acquisition and processing device to perform the ECG exam. The data is transmitted through a wireless handheld device and stored in a remote server for subsequent clinical analysis. / Atualmente quem procura assistência médica hospitalar comumente se depara com os problemas de falta de vagas, alto custo, risco de infecção, impossibilidade de deslocamento, necessidade de adaptação aos novos ambientes e a uma nova dieta, sentimento de improdutividade, isolamento de seu ambiente de trabalho, entre outros. O objetivo deste projeto e fazer uso da telemedicina para monitoramento remoto móvel de sinais biológicos de pacientes para reduzir o número de internações em hospitais e clínicas e ainda com menor custo. Mais especificamente desenvolver e documentar o projeto de um sistema portátil de aquisição, processamento e telemonitoração de sinais biológicos de pacientes, permitindo a sua mobilidade e um padrão de vida mais próximo da sua rotina diária normal. Este sistema é composto de um dispositivo de aquisição e processamento de parâmetros biológicos do paciente, portátil, possibilitando a aquisição de sinais biológicos do paciente necessários para a realização de eletrocardiogramas (ECG). Estas informações podem ser enviadas através de um protocolo Wireless (WiFi ou Bluetooth) para uma estação remota para posterior análise clinica.
27

Desenvolvimento e validação de um sistema de monitoração de leitos hospitalares

Haas, Guilherme Rodrigues January 2012 (has links)
Made available in DSpace on 2013-08-07T18:53:24Z (GMT). No. of bitstreams: 1 000439846-Texto+Completo-0.pdf: 3140948 bytes, checksum: 37438f4fc0e85d46c270e73b24a4ee0b (MD5) Previous issue date: 2012 / The health care system began to be developed from the 90's, with the aim of gathering information of beds in a common point. Developed by manufacturers of patient monitors, health care system have evolved over the years, bringing more and more tools for monitoring of patients and help health professionals. Against these objectives this thesis is to develop, along with Toth technology company located in Technology Park PUCRS, a medical device company Lifemed and with the support of the Microgravity Laboratory, a world reference in the field of aerospace physiology, a cental station system. This thesis has developed a platform for remote monitoring interface with paitent monitors of Lifemed company, able to manage and centralize physiological information from patients monitored. For the development of the central station, were created two software able to organize, manage and view information from all the monitors connected to the system. Both software were developed in C++, a programming language that combines both the necessary structure for visual applications with the needs of low-level interaction for real-time systems. The communication protocol TCP / IP, one of the strongest communication systems used in Ethernet applications, was chosen for the communication between the system and monitors. Performance tests were designed to evaluate the data integrity, system stability and reliability of data displayed. The developed system has the ability to manage up to 50 monitors Lifetouch-10 from the TCP / IP and store 96 hours of physiological data of each patient monitored. Each platform is able to simultaneously display 12 physiological waveforms and 8 parameters from up to 32 monitors in real-time, providing pre-configured technical and physiological alarms and multi speed waveform visualization. It is believed that with the implementation of remote monitoring systems in hospital environments factors such as patient mortality is reduced, improving treatment and care of hospitalized patients. / As centrais hospitalares começaram a ser desenvolvidas a partir da década de 90, com o objetivo de reunir informações dos leitos em um ponto comum. Desenvolvidas por fabricantes de monitores multiparamétricos, as centrais vêm evoluindo ao longo dos anos, trazendo cada vez mais ferramentas para a monitoração dos pacientes e o auxílio aos profissionais da saúde. Ao encontro a esses objetivos essa dissertação vem desenvolver, junto a empresa de tecnologia Toth, situada no parque tecnológico da PUCRS, a empresa de equipamentos médicos LifeMed e com o apoio do Centro de Microgravidade, referência mundial na área de fisiologia aeroespacial, uma central de monitoração de leitos hospitalares. Nessa dissertação foi desenvolvida uma plataforma de monitoração remota para interface com os monitores multiparamétricos Lifrtouch-10 da LifeMed, capaz de gerenciar e centralizar informações fisiológicas de pacientes monitorados. Para o desenvolvimento da central, foram criados dois softwares capazes de organizar, gerenciar e visualizar as informações de todos os monitores conectados ao sistema. Ambos os softwares foram desenvolvidos em C++, uma linguagem de programação que mescla ao mesmo tempo a estrutura necessária para aplicações visuais com as necessidades de interação de baixo nível para sistemas de tempo real. O protocolo de comunicação TCP/IP, um dos mais robustos utilizado em sistemas de comunicação ethernet, foi escolhido para a comunicação entre o sistema e os monitores. Foram criados testes de desempenho para avaliação da integridade dos dados, estabilidade do sistema e confiabilidade dos dados visualizados.O sistema desenvolvido tem a capacidade de gerenciamento de até 50 monitores Lifetouch-10 a partir do protocolo TCP/IP e armazenar 96 horas de dados fisiológicos de cada paciente monitorado. Cada plataforma de visualização é capaz de mostrar 12 curvas fisiológicas e 8 parâmetros de até 32 monitores conectados em tempo real, assim como parâmetros de configuração do monitor e alarmes fisiológicos. Acredita-se que com a implantação de sistemas de monitoração remota em ambientes hospitalares fatores como mortalidade de pacientes seja reduzido, melhorando o tratamento e o cuidado dos pacientes internados.
28

Metodologia de priorização de equipamentos medicos para programas de manutenção preventiva em hospitais

Ferreyra Ramirez, Ernesto Fernando 02 December 1996 (has links)
Orientador: Said Jorge Calil / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-07-21T20:43:49Z (GMT). No. of bitstreams: 1 FerreyraRamirez_ErnestoFernando_M.pdf: 4191425 bytes, checksum: f333b450c6c2fa05078c8f9cc47d9f7c (MD5) Previous issue date: 1996 / Resumo: Atualmente, as pressões para aumento da segurança e disponibilidade dos equipamentos médicos, e a limitação de recursos humanos e financeiros têm mostrado a necessidade de implantação de programas de manutenção preventiva. O alto custo deste tipo de manutenção obriga o desenvolvimento de programas que priorizem os equipamentos nos hospitais brasileiros. Este trabalho propõe uma metodologia para suprir esta necessidade. A metodologia proposta considera os fatores: I)Risco para o paciente e usuário do equipamento; 2)Importância estratégica do equipamento e Recomendações do fabricante e órgãos fiscalizadores; 3)Análise da viabilidade de manutenção preventiva; e 4)Análise periódica do histórico de falhas e consertos dos equipamentos. A estes fatores são atribuídos pontos, de modo a formar um número de prioridade (PE). Os resultados encontrados em um estudo de caso efetuado mostram que a metodologia é condizente com a realidade nacional devido à sua facilidade de implementação mesmo para o caso em que não haja dados anteriores sobre o histórico / Abstract: Nowadays, the increasing need of improving the safety and the availability of medical equipment, and the restrictions of human and financial resources have shown the importance of implementation of preventive maintenance programs. The high costs of this type of maintenance lead to the development of equipment prioritizing programs in the Brazilian hospitaIs. This work suggests a methodology to fuifiII this need. The proposed methodology considers the factors: 1) Physical Risk to the patient and to the user; 2) Equipment strategic importance and manufacturers' and accreditation entities recommendations; 3) Viability analysis of the preventive maintenance; and 4)Periodic analysis of the equipment failures and repair history. These factors receive ponderation in order to achieve an equipment priority number (PE). The results found in a case study showed the proposed methodology agrees with the national reality because it's easy to implement though the equipment maintenance history data were limited. / Mestrado / Engenharia Biomedica / Mestre em Engenharia Elétrica
29

Contribuição ao estudo da estabilização do polipropileno a radiação gama do cobalto-60 para aplicação em seringas descartaveis

Nascimento, Elias Severino do 16 December 1999 (has links)
Orientador: Edison Bittencourt / Tese (doutorado) - Universidade Estadual de Campinas. Faculdade de Engenharia Quimica / Made available in DSpace on 2018-07-26T23:17:06Z (GMT). No. of bitstreams: 1 Nascimento_EliasSeverinodo_D.pdf: 6337800 bytes, checksum: 1aa735540399593b1b0d636708400587 (MD5) Previous issue date: 1999 / Resumo: Propileno (PP) é um polímero muito utilizado na confecção de artefatos de uso médico-cirúrgico ou em embalagem de alimentos. A irradiação gama é a técnica mais aceita para esterilização destes materiais (dose entre 10kGy e 60kGy). Entretando a interação da radiação gama com o propileno, promove a degradação do polímero tornando-o amarelado e quebradiço. Isto ocorre porque, durante o período de irradiação, ocorre a ruptura de algumas ligações C-C ou C-H, dando origem a radicais livres alquila. Tais radicais alquila são muito instáveis e se oxidam rapidamente transformando-se em radicais peroxil os quais reagem com moléculas do polímero produzindo novos radiacais alquila. Calculou-se o tempo necessário para que haja a difusão do oxigênio em um filme de 1mm de espessura, verificou-se que este tempo é muito pequeno (minutos) comparado ao tempo de irradiação (horas), implicando numa situação de oxigênio abundante que favorece a oxidação. Foram elaboradas amostras de PP aditivado com estearato de cálcio (0,10%) antioxidande fenólico (0,20%) e um desativador de estado excitado (quenquer). O absorvedor ultravioleta Chimassorb-81 foi usado (0,10%) a fim de se estudar se seria capaz se atuar como quncher. As amostras foram irradicadas até a dose de 100kGy. A contribuição do Chimassorb-81 foi positiva, conferindo estabilidade as propriedades mecânicas, porem acentuando o amarelecimento causado pelos antioxidantes fenólicos em cerca de 25% (25kGy). ...Observação: O resumo, na íntegra, poderá ser visualizado no texto completo da tese digital / Abstract: Polypropylene (PP) is a polymer wide used in the manufacture of medical-surgical supplies and food packing. The gamma radiation is the more acceptable technique for sterilization of these materials (dose between 10kGy and 60kGy). However the interaction of the gamma radiation with the polypropylene promotes the degradation of the polymer turning it yellowish and brittle. This happens because, during the irradiation period, occurs rupture of some chemical bond C-C or C-H, producing free alkyl radicals. Such alky radicals are very unstable and they are quickly oxidized becoming peroxy radicals which react with others molecules of the polymer producing news alkyl radicais. It was calculated the necessary time so that there is the diffusion ofthe oxygen in a film of 1mm of thickness, it was verified that this time is very small (minutes) compared at the time of irradiation (hours), implying in a situation of abundant oxygen that favors the oxidation. Samples of PP with additives were elaborated with calcium-stearate (0,10%), phenol stabilizer (0,20%) and a quencher. The ultraviolet absorverdor Chimassorb-81 were used (0,10%) in order to study if it would be capable to act as a quencher. The samples were irradiated until the dose of 100kGy ...Note: The complete abstract is available with the full electronic digital thesis or dissertations / Doutorado / Doutor em Engenharia Química
30

Instrumento de quantifica??o de movimentos de cabe?a durante a avalia??o de equil?brio

Bregolin, Alexandre Dal Pizzol 23 August 2013 (has links)
Made available in DSpace on 2015-04-14T13:56:29Z (GMT). No. of bitstreams: 1 452831.pdf: 4042565 bytes, checksum: 5767bd96616a703ddf72b745e82d59b2 (MD5) Previous issue date: 2013-08-23 / This thesis describes the development of an instrument in the analysis and research of human balance. The instrument operates by providing data quantifying the selective head movements performed during measurement of the vestibular-ocular reflex (VOR). The VOR acts to stabilize the eye, to ensure a clear view during head movements. One of the techniques used in the evaluation of the vestibular system aims to observe the VOR in response to selective movements of the head. The algorithm developed for this study uses digital signal processing of three-dimensional data acquired by a sensor Kinect for Windows from Microsoft, and the detection of colored marks affixed to the quantification device of VOR in predetermined locations and with specific distances between the marks. The developed application allows the acquisition and display, graphically and synchronized, of the acquired data during the quantification of the stimuli used during the measurement of VOR. These graphs are corresponding to the three possible directions of rotation of the head where the VOR responds: horizontal (yaw), vertical (pitch) and torsional (roll). The application was developed with the C# programming language. Tests to evaluate the robustness and accuracy of the instrument were conducted through a device developed in this thesis, which performs mechanically, by means of a servomotor controlled movements, the movement of the marks. These movements were programmed to simulate the selective movements of head at different amplitudes and velocities. / Este trabalho apresenta o desenvolvimento de um instrumento de auxilio ? an?lise e pesquisa do equil?brio humano. O instrumento atua fornecendo dados da quantifica??o dos movimentos seletivos de cabe?a exercidos durante a medi??o do reflexo vest?bulo-ocular (RVO). O RVO atua na estabiliza??o do olhar para assegurar uma vis?o clara durante os movimentos da cabe?a. Uma das t?cnicas utilizadas na avalia??o do sistema vestibular visa observar o RVO em resposta a movimentos seletivos da cabe?a. O algoritmo desenvolvido para este trabalho utiliza o processamento digital de dados tridimensionais adquiridos atrav?s de um sensor Kinect for Windows da Microsoft, e a detec??o de marcas coloridas afixadas no dispositivo de quantifica??o do RVO em locais pr?-determinados e com dist?ncias espec?ficas entre as marcas. O aplicativo desenvolvido permite a aquisi??o e exibi??o, de forma gr?fica e sincronizada, dos dados adquiridos durante a quantifica??o dos est?mulos utilizados durante a medi??o do RVO. Estes gr?ficos s?o correspondentes aos tr?s poss?veis sentidos de rota??o de cabe?a aos quais o RVO responde: horizontal (yaw), vertical (pitch) e de tor??o (roll). O aplicativo foi desenvolvido com a linguagem de programa??o C#. Os testes para avaliar a robustez e precis?o do instrumento foram realizados atrav?s de um dispositivo desenvolvido nesta tese, que desempenha de forma mec?nica, atrav?s de movimentos controlados de um servomotor, o movimento das marcas. Estes movimentos foram programados de forma a simular os movimentos seletivos de cabe?a em diferentes amplitudes e velocidades.

Page generated in 0.1449 seconds