• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1048
  • 284
  • 85
  • 3
  • 1
  • 1
  • Tagged with
  • 1419
  • 294
  • 279
  • 162
  • 156
  • 134
  • 123
  • 121
  • 92
  • 87
  • 85
  • 78
  • 74
  • 74
  • 73
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
171

Développement d'une nouvelle méthode de mesure du rythme cardiaque et du débit sanguin fondée sur les perturbations localisées d'un champ magnétique

Phua, Chee Teck 21 September 2012 (has links) (PDF)
La mesure et le contrôle du pouls et du flux sanguin en continu sont d'importants paramètres pour l'évaluation de signes essentiels physiologiques sur la condition de santé d'un individu. Les dispositifs commerciaux existants, ainsi que les méthodes de recherche ou utilisées dans le milieu médical exigent un bon contact électrique ou optique pour obtenir cette mesure en continu. Pendant ces travaux de recherche, une méthode originale non invasive de mesure du rythme cardiaque fondée sur la perturbation localisée d'un champ magnétique au passage du flux sanguin a été développée, permettant l'acquisition des signaux à travers les vêtements, la transpiration, les salissures ou autres polluants dans l'environnement proche du capteur. Cette méthode est appelée la Signature Sanguine par Modulation Magnétique (MMSB) et les mesures ont été accomplies sur de multiples individus. Le système a été modélisé mathématiquement et simulé dans un environnement multiphysique, puis validé par l'utilisation des données expérimentales. Les résultats de mesure, en utilisant la méthode MMSB, pour le pouls et le flux sanguin ont été comparés et se trouvent bien corrélés, avec les résultats obtenus grâce à d'autres instruments. De plus, deux dispositifs ont été développés et sont en cours de commercialisation, pour des applications de vie quotidienne
172

LEVITATION ELECTROMAGNETIQUE<br />Expériences terrestres et simulations numériques

Bardet, Benoit 24 November 2006 (has links) (PDF)
La thèse réalisée est à la fois expérimentale et numérique. Une expérience de lévitation<br />électromagnétique a été mise en oeuvre avec un traitement d'images. Les vidéos<br />obtenues ont servi de base pour avoir des données géométriques et électriques afin de<br />confronter les résultats de divers codes de calcul à des expériences maîtrisées et afin de<br />mettre en évidence l'effet de l'hélicité de l'inducteur sur la forme de la surface libre ;<br />ainsi que pour comprendre et maîtriser le comportement d'une goutte sous champ<br />magnétique modulé pour des fréquences de modulation proches de la fréquence de résonnance<br />naturelle de la charge. Le travail numérique a permis de valider des codes de<br />simulation axisymétrique pour la description de l'électromagnétisme, pour la forme<br />moyenne de la surface libre et pour les mouvements de la surface et à l'intérieur de la<br />goutte. Un critère de déstabilisation basé sur la déformation initiale de la goutte tenant<br />compte du brassage électromagnétique a été mis en avant.
173

Mesure adaptative non destructive du nombre de photons dans une cavité

Peaudecerf, Bruno 30 September 2013 (has links) (PDF)
Une mesure adaptative vise à optimiser l'acquisition d'information sur un système à l'aide d'une boucle de rétroaction sur l'appareil de mesure. Dans notre dispositif d'électrodynamique en cavité, nous avons réalisé une mesure adaptative sur un système quantique, le champ micro-onde piégé dans une cavité supraconductrice de très grande finesse. Des atomes de Rydberg circulaires, interagissant dispersivement avec le champ, réalisent une série de mesures dites "faibles", aboutissant à la mesure quantique non destructive du nombre de photons dans le mode. La prise en compte des résultats des mesures successives, de l'action en retour sur le système, et de l'ensemble des imperfections expérimentales, permet à un ordinateur de contrôle d'effectuer une estimation en temps réel de l'état du champ. La phase de l'interféromètre de Ramsey qui définit la mesure réalisée sur les atomes est alors optimisée afin d'extraire un maximum d'information des détections ultérieures. Nous montrons que préparation d'états de Fock est nettement accélérée avec la méthode adaptative, par rapport à un protocole passif utilisant une alternance prédéfinie des phases de mesure. Cette réduction du temps de mesure est d'un grand intérêt en présence de décohérence, et pourrait par exemple être exploitée dans des protocoles de rétroaction quantique existants, où la rapidité de l'estimation d'état est cruciale.
174

Développement des techniques optiques et acoustiques de mesure de champs orientées vers la vibroacoustique

Nistea, Ioana Theodora 06 December 2010 (has links) (PDF)
L'utilisation des techniques de mesure optiques impose un choix, souvent difficile, entre la résolution temporelle et la résolution spatiale. L'interferométrie Speckle (IS) fournit des mesures des champs d'amplitudes de vibration de grande résolution spatiale, mais la résolution temporelle des mesures est réduite par les cadences d'acquisition des détecteurs. La thèse est dédiée au développement d'un système interférométrique adapté à la mesure des vibrations et des phénomènes dynamiques des structures, basé sur les principes de l'IS, mais ayant une résolution temporelle accrue. Le système a été testé à des cadences de plus de 26000 images/s pour les cas suivants : sollicitation harmonique mono-fréquence ou par une forme d'onde arbitraire ; sollicitation dynamique par une séquence d'échelons de force ; choc mécanique. Les essais ont démontré que le système est capable de dépasser les systèmes classiques d'IS à laser continu en ce qui concerne la mesure des phénomènes dynamiques.
175

Dimension de Hausdorff des ensembles limites / Hausdorff dimension of the limit set

Dufloux, Laurent 06 October 2015 (has links)
Soit G le groupe SO°(1, n) (n ≥ 3) ou PU(1, n) (n ≥ 2) et fixons une décomposition d'Iwasawa G = KAN. Soit ɼ un sous-groupe discret de G, que nous supposons Zariski-dense et de mesure de Bowen-Margulis-Sullivan finie. Lorsque G = SO°(1, n), nous étudions la géométrie de la mesure de Bowen-Margulis-Sullivan le long des sous-groupes fermés connexes de N, en lien avec la dichotomie de Mohammadi-Oh. Nous établissons des résultats déterministes sur la dimension des projections de la mesure de Patterson- Sullivan. Lorsque G = PU(1, n), nous relions la géométrie de la mesure de Bowen- Margulis-Sullivan le long du centre du groupe de Heisenberg au problème du calcul de la dimension de Hausdorff de l'ensemble limite relativement à la distance sphérique au bord. Nous calculons cette dimension pour certains groupes de Schottky. / Let G be the group SO° (1,n) (n ≥ 3) or PU(1, n) (n ≥ 2) and fix some Iwasawa decomposition G = KAN. Let ɼ be a discrete subgroup of G.We assume that ɼ is Zariski-dense with finite Bowen-Margulis-Sullivan measure. When G = SO°(1,n), we investigate the geometry of the Bowen-Margulis-Sullivan measure elong connected closed subgroups of N. This is related to the Mohammadi-Oh dichotomy. We then prove deterministic results on the dimension of projections of Patterson-Sullivan measure. When G = PU(1,n), we relate the geometry of Bowen-Margulis-Sullivan measure along the center of Heisenberg group to the problem of computing the Hausdorff dimension of the limit set with respect to the spherical metric on the boudary. We construct some Schottky subgroups for wich we are able to compute this dimension.
176

Développement d’un capteur à fibre optique à base de réseaux de Bragg superposés de courtes et de longues périodes : application à la mesure discriminée de température et de déformation / [Development of an optical fiber sensor based on superimposed fiber Bragg and long period gratings] : [application to the discriminate measurement of temperature and strain]

Triollet, Sébastien 03 December 2010 (has links)
[Les capteurs à fibres optiques présentent des qualités intéressantes en termes de tailles et de poids relativement faibles qui permettent de réduire l'intrusivité du capteur dans le matériau (ou dans la structure composite). Ils sont également insensibles aux perturbations électromagnétiques, stables et durables dans le temps, mais aussi sensibles à plusieurs sollicitations comme la température, la déformation et la pression, d'où un besoin essentiel de les discriminer. Parmi eux on distingue les réseaux de Bragg : ceux à courtes périodes (FBG : Fiber Bragg Grating) et ceux à longues périodes (LPG : Long Period Grating). Le travail de thèse reporté dans ce manuscrit, traite du développement d'un capteur à fibre optique basé sur la superposition d'un LPG et d'un FBG afin de mesurer et de discriminer la température et la déformation. De nombreuses approches sont proposées dans la littérature afin de découpler ces deux sollicitations cependant elles ne permettent pas forcément une utilisation en conditions réelles de mesures. C'est pourquoi nous introduisons la notion d'efficacité de découplage avec le paramètre E qui permet de comparer toutes ces approches et met en évidence un très bon potentiel pour la structure à base de réseaux superposés LPG/FBG. La mise en œuvre d'un tel composant est décrite dans ce manuscrit et consiste à inscrire initialement le LPG puis le FBG au même endroit et sur toute la longueur du LPG. De plus ce type de structure permet un multiplexage qui, bien que faible, est néanmoins possible. Les étalonnages en température et en déformation du capteur ont permis de mettre en évidence une erreur de l'ordre de 2% sur la sensibilité à la température et de 3% sur la sensibilité à la déformation, ce qui conduit à une erreur sur l'estimation de la température et de la déformation mesurée de l'ordre de 0.3°C et 3 microdef. Dans un souci applicatif, le capteur à base de réseaux de Bragg superposés est tout d'abord utilisé pour instrumenter une structure métallique soumise simultanément à une variation de température et de déformation. Les valeurs mesurées présentent une incertitude maximale de 0.4°C pour la température et de 3 me pour la déformation ce qui permet de valider notre composant pour le contrôle et la surveillance de structures métalliques. La seconde application étudiée est relative à l'instrumentation de pièces composites stratifiées de type verre/époxy pour le suivi de procédés d'élaboration par voie liquide : VARTM (Vacuum Assisted Resin Transfer Molding) et LRI (Liquid Resin Infusion), pour lesquels l'évolution de la température et de la déformation au cours du procédé est suivie par le capteur à base de réseaux de Bragg superposés LPG/FBG. Des mesures diélectriques (DEA) sont également réalisées au cours de ces procédés et permettent la comparaison et la validation de nos résultats] / [Optical Fibre Sensors present some interesting qualities when considering its size and weight relatively light, which lead to a low intrusivity of the sensor in a material (a composite structure). These sensors are insensitive to electromagnetic phenomenon, stable and long lasting with time, but sensitive to several solicitations such as temperature, strain and pressure hence a real need of discrimination. Among these sensors, we may discern the Bragg gratings: the Long Period Grating one (LPG) and the Fibre Bragg Grating (FBG) one. This thesis work reports the development of an optical fibre sensor based on two superimposed Bragg gratings: LPG and FBG for measuring and discriminating temperature and strain. Several studies are reported in literature without getting a real condition use. That's why we propose a parameter E, which stand for the discrimination efficiency leading to a possible comparison of the existing techniques and highlight the quite good potential of superimposed Bragg gratings. The settings of such a structure are given in this thesis report and consist in writing LPG first, then FBG over the entire length of the LPG, which also gives multiplexing possibilities. Strain and temperature calibration steps give sensitivities errors of 2% for temperature and 3% for strain, which lead to estimated errors on measured strain and temperature of 0.3°C and 3 microstrain respectively. In an application point of view, the sensor has been used for the instrumentation of a metallic structure subjected to a variation of temperature and strain applied simultaneously. The results exhibit a maximum error of 0.4°C and 3me for temperature and strain respectively, which is a good validation of the sensor for structural control and monitoring purpose. The second studied application is about instrumentation of glass/epoxy composite specimen for monitoring manufacturing processes: VARTM (Vacuum Assisted Resin Transfer Moulding) and LRI (Liquid Resin Infusion), for which temperature and strain have been monitored with the superimposed Bragg gratings based sensor. Dielectric analyses have also been performed during those processes in order to compare and validate our results]
177

La notion de première impression dans la perception de nouveaux produits : une comparaison de méthodes de mesure / The concept of the first impression in the perception of new products : a comparison of measurement method / Khái niệm về ấn tượng ban đầu trong nhận thức về sản phẩm mới bởi người tiêu dùng : một sự so sánh về phương pháp đo lường

Ngo, Thi Khue Thu 31 May 2013 (has links)
La notion de première impression est fréquemment utilisée dans la socio-psychologie mais elle n'a pas été fortement exploitée dans le marketing. Même si cette notion apparait souvent dans le monde du commerce, il n’est pas toujours facile de la mesurer. La comparaison de deux méthodes de mesure nous permet d’affirmer d’une part, que sur un nouveau produit, la première impression est formée dans les 10 premières secondes, et d’autre part, qu’elle apporte sur ce produit une perception minimale. Le processus d’expérimentation a été réalisé sur de nouvelles voitures en voie de commercialisation au Vietnam. Les résultats obtenus sont convergents et cette thèse montre bien les intérêts mais aussi les limites de concept psychologique. / The concept of first impression is frequently used in social psychology, but it hasn’t been forcefully exploited in Marketing. Even though this notion appears daily in the business world, it is not always easily measured. The comparison of two methods allows us to affirm that the first impression of the new products is formed during the first 10 seconds and then, it provides us minimal perception of product. The process of the experiment was seriously carried out among new cars being commercialized in Vietnam. The results are convergent and this thesis shows not only the interests but also the limits of this psychological concept. / Khái niệm về ấn tượng ban đầu thường xuyên được sử dụng trong tâm sinh lý xã hội nhưng vẫn chưa thật sự được khai thác mạnh mẽ trong Marketing. Ngay cả khi ấn tượng ban đầu xuất hiện hàng ngày trong thế giới thương mại, nhưng thật không dễ để đo lường được nó. Một sự so sánh về hai phương pháp đo lường cho phép chúng ta khẳng định rằng ấn tượng ban đầu về sản phẩm mới được hình thành ngay từ 10 giây đầu tiên và đã mang đến cho chúng ta một nhận thức tối thiểu về sản phẩm. Việc xây dựng tiến trình thực nghiệm đã được thực hiện một cách nghiêm túc trên những chiếc xe ô tô mới đang trên đường được thương mại hóa tại Việt Nam. Những kết quả đạt được là hội tụ và cuốn luận án cũng đã chỉ rõ những lợi ích cũng như giới hạn từ khái niệm tâm sinh lý này.
178

Développement d'une stratégie de testing informatisée et interactive, centrée sur le diagnostic pédagogique dans le contexte de la classe

Perron, Michèle 04 1900 (has links)
Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal. / Ce mémoire présente le développement d'une stratégie de testing informatisée et interactive, centrée sur le diagnostic pédagogique dans le contexte de la classe. La nouvelle stratégie d'administration d'un test a été intégrée à un système de tests adaptatifs existant, conçu pour répondre à un besoin d'outils pour revaluation formative qui respectent les contraintes organisationnelles du milieu scolaire québécois. Le système développé a pour but de renseigner rapidement renseignant et l'élève de l'état des apprentissages de celui-ci sans délai, afin que renseignant puisse entreprendre des interventions correctives efficaces auprès des élèves. Le système de tests réalisé administre un test en deux phases. La première phase fournit un diagnostic structurel ainsi qu'une hypothèse du diagnostic causal reflétant les apprentissages d'un élève. La seconde phase du test permet d'établir un niveau de cohérence d'un élève présentant une difficulté cognitive préalablement identifiée dans la première phase et de communiquer ce diagnostic causal sous la forme d'un message qualitatif pour renseignant. Pour répondre aux objectifs de la première phase du test, nous avons modifié la programmation de la stratégie "stradaptative" existante pour la rendre plus flexible et indépendante des banques d'items. Nous avons procédé à la verification de l'algorithme de sélection des items "stradaptatif" par une étude de vérification simulant différents profils d'élèves. Pour répondre aux objectifs de la seconde phase, nous avons convenu d'utiliser la catégorie de leurres la plus fréquemment choisie par l'élève lors de la première phase du test comme élément d'information pour la seconde phase. Nous avons ajouté au système de tests diagnostiques existant, une stratégie de selection adaptative des items selon un modèle Rasch nécessaire pour estimer le niveau de difficulté cognitive de l'élève face à une catégorie de leurres donnée. n IV Nous avons établi, à partir des résultats des études de simulations, des intervalles de confiance pour les thêta moyens estimés correspondant à des niveaux de difficulté cognitive et des profils d'élèves différents. A partir de ces intervalles, nous avons défini trois niveaux de messages diagnostiques exprimant le niveau de cohérence de l'élève à choisir une catégorie de leurres donnée : la difficulté n'est pas cohérente, la difficulté présente un certain degré de cohérence, la difficulté est cohérente. Le diagnostic structurel et le diagnostic causal sont accessibles immédiatement après la passation du test par l'entremise de la fiche diagnostique individuelle de l'élève. Cette recherche a permis d'intégrer dans un même système de tests, la stratégie "stradaptative" dont la programmation a été rendue indépendante du contenu des banques et une stratégie complémentaire de sélection des items utilisant le modèle de Rasch qui permet de déterminer un niveau de cohérence de l'élève à choisir une certaine catégorie de leurres.
179

Détermination du module réversible des matériaux granulaires à l'aide de l'essai pressiométrique

Ciza, Ferdinand 17 April 2018 (has links)
L’une des raisons de la dégradation prématurée des routes en Amérique du Nord serait les propriétés mécaniques inadéquates des matériaux. Devant le peu d’informations sur le comportement anisotrope des matériaux granulaires dans la littérature, le service des matériaux d’infrastructure du ministère des Transports du Québec a accepté de soutenir le projet (GE-004-09) qui porte sur la détermination du module réversible des matériaux granulaires utilisés pour construire les fondations des routes. Les études montrent que le module réversible (MR) des sols de chaussée est un paramètre essentiel pour le dimensionnement et l’analyse des chaussées revêtues d’enrobé. Selon la méthode de conception (AASHTO, 2002), les différentes couches de la structure de la chaussée sont choisies et dimensionnées de façon à ce que la couche d’infrastructure reste dans la limite des tolérances des déformations élastiques. Afin de déterminer le MR, des essais triaxiaux et pressiométriques ont été effectués dans les installations du ministère des Transports du Québec. Les essais pressiométriques ont été réalisés dans un moule compacteur, conçu spécialement pour effectuer les essais verticaux et horizontaux. Les résultats obtenus des essais pressiométriques diffèrent de ceux des essais triaxiaux (13 kg de matériau granulaire). Des valeurs obtenues à partir de l’essai pressiométrique sur un matériau représentatif de chaussée (72 kg) démontrent qu’il y a une évidence d’anisotropie stucturale dans la fondation et la sous-fondation. Il ressort que le rapport d’anisotropie (Er/Ez ) est à peu près égal à 15 %, ce qui concorde avec celui de Tutumluer et al., (2003). Finalement, l’essai pressiométrique est très prometteur car il permet non seulement la détermination de l’anisotropie, mais il permet à l’ingénieur de développer une confiance dans les résultats à cause de la forme de la courbe pression-volume. / One reason for the premature deterioration of roads in North America is inadequate mechanical properties of materials. Given the limited information on the anisotropic behavior of granular materials in the literature, the « Service des matériaux d’infrastructure du ministère des Transports du Québec » agreed to support the project (GE-004-09) which relates to the determination of resilient modulus of granular materials used to build the foundations of roads. Studies show that the resilient modulus of pavement soils is a key parameter for the design and analysis of paved asphalt roads. According to the design method (AASHTO, 2002), the different layers of the pavement structure are dimensioned so that the infrastructure layer remains within tolerated limits of elastic deformations. In order to determine the resilient modulus, triaxial and pressuremeter tests were performed in the facilities of the « Ministère des transports du Québec ». Pressuremeter tests were carried out in a mold compactor, designed specifically for vertical and horizontal testing. The results of pressuremeter tests differ from those (13 kg of granular material) of the triaxial tests. Values obtained from the pressuremeter tests on representative road material (72 kg), demonstrate the existence of structural anisotropy in the foundation and subgrade sections. It appears that the anisotropic ratio (Er/Ez) is roughly equal to 15%, which is consistent with results obtained by Tutumluer et al., (2003). Finally the pressuremeter test is very promising because, not only does it allows for the determination of anisotropy, but also allows the engineer to develop confidence in the results due to the shape of the pressure-volume curve.
180

Relations entre les coefficients d'adsorption de l'atrazine et les caractéristiques physico-chimiques et colorimétriques de la phase organique de différents sols

Béland, Kathleen 12 April 2018 (has links)
Ce projet d'étude, qui a pour but de développer un indice simple à déterminer fournissant des informations sur la rétention de l'atrazine dans les sols, a mis en relation les différents coefficients d'adsorption existants (Kd, Kf, Koc) et deux indices colorimétriques. La méthode utilisée pour déterminer les indices colorimétriques est celle au pyrophosphate de sodium de Kaila. Cette dernière est facile, rapide et accessible à tous les laboratoires d'analyses. Les principales conclusions de l'étude sont les suivantes : 1. L'indice colorimétrique au pyrophosphate de sodium de Kaila est applicable aux sols minéraux. Les lectures obtenues en absorbance sont valables et reproductibles pour les 11 sols minéraux de l'étude. 2. La méthode colorimétrique au pyrophosphate de sodium de Kaila est une méthode simple, rapide et relativement peu coûteuse à effectuer. Les modifications apportées à la méthode n'entraine pas de changements majeurs au niveau des coûts et de la faisabilité. 3. L'indice colorimétrique de Kaila standard ne semble pas être relié avec les paramètres de la rétention de l'atrazine tels que 1/Kd et Kdoc. 4. L'indice colorimétrique de Kaila en version modifiée semble être relié avec les paramètres de la rétention de l'atrazine tels que 1/Kd et Kdoc. 5. L'indice colorimétrique de Kaila en version modifiée semble être inversement proportionnel à la rétention de l'atrazine. 6. Les indices colorimétriques de Kaila (standard ou modifié) semblent être des outils qui peuvent nous apporter des informations sur la rétention de l'atrazine dans les sols minéraux ainsi que dans les sols organiques.

Page generated in 0.0231 seconds