• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • 1
  • Tagged with
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Étude des COV issus de la dégradation thermique et oxydative des matériaux polymères

Latappy, Hubert 10 July 2014 (has links) (PDF)
Les matériaux polymères sont aujourd'hui très présents dans notre environnement et deviennent irremplaçables pour de nombreuses applications : emballage, textile, mobilier,... La connaissance du cycle de vie de ces matériaux, de la production à leur destruction, devient importante pour nos sociétés. Par exemple ces matériaux peuvent émettre des Composés Organiques Volatils qui sont souvent toxiques et leur impact sur le milieu doit être évalué. L'objectif de ce travail de thèse a été de développer une méthode au laboratoire pour identifier et quantifier ces émissions. La difficulté provient de la grande diversité des composés qui peuvent être émis. Par ailleurs la méthode nécessite une fréquence de mesure élevée (temps réel) souvent incompatible avec les techniques actuelles. Une solution analytique couplant un four et un spectromètre de masse haute résolution associé à une méthode d'ionisation chimique contrôlée a été développée. Celle-ci est basée sur un spectromètre FT-ICR compact à bas champ magnétique : BTrap. Les points forts de cette technique sont la très haute résolution en masse qui permet de mesurer la masse exacte des composés et la détection multi composés, simultanée sur toute la gamme de masse. L'ionisation chimique contrôlée permet l'ionisation douce et quantitative des molécules d'intérêt. Le transfert de proton à partir de l'ion H₃O⁺ (PTRMS) a montré son potentiel pour la détection des COV dans de nombreux domaines. Après une présentation du contexte et du besoin, le dispositif expérimental développé est détaillé. La validation de celui-ci pour l'analyse de gaz traces a été effectuée au LPGP, sur un système de dépollution par plasma froid. Les résultats de dégradation de l'acétaldéhyde en fonction des conditions de fonctionnement du réacteur sont présentés.L'ionisation par PTR conduit habituellement à la molécule protonée ce qui simplifie l'identification. Cependant des fragmentations peuvent être observées. L'utilisation d'un précurseur d'ionisation chimique plus lourd et moins réactif que H₃O⁺ pourrait minimiser ces phénomènes. L'utilisation du diflurobenzène protoné a été testée et comparée à celle de l'ion H₃O⁺. Pour cela, des études cinétiques ont été menées sur une série d'alcools connus pour fragmenter avec H₃O⁺, et confirment l'intérêt du nouveau précurseur.Le poly(méthacrylate de méthyle) (PMMA) est un matériau très répandu : plexiglass. Sa dégradation est a priori relativement simple puisqu'il s'agit très majoritairement d'une dépolymérisation, accompagnée de la formation de produits minoritaires. En conséquence, son étude nous a paru intéressante pour la mise au point et la validation de la méthode. La dégradation du PMMA a été étudiée sous atmosphère inerte, puis oxydante. Les résultats obtenus sont présentés : produits émis, bilan en masse, et apport du suivi en temps réel de la dégradation, montrant en particulier que les produits minoritaires sont émis après le monomère.Enfin une dernière partie de conclusion présente les perspectives pour cette nouvelle méthode.
2

Étude des COV issus de la dégradation thermique et oxydative des matériaux polymères / Study of VOC emitted by thermal and oxidative degradation of polymeric materials

Latappy, Hubert 10 July 2014 (has links)
Les matériaux polymères sont aujourd'hui très présents dans notre environnement et deviennent irremplaçables pour de nombreuses applications : emballage, textile, mobilier,... La connaissance du cycle de vie de ces matériaux, de la production à leur destruction, devient importante pour nos sociétés. Par exemple ces matériaux peuvent émettre des Composés Organiques Volatils qui sont souvent toxiques et leur impact sur le milieu doit être évalué. L’objectif de ce travail de thèse a été de développer une méthode au laboratoire pour identifier et quantifier ces émissions. La difficulté provient de la grande diversité des composés qui peuvent être émis. Par ailleurs la méthode nécessite une fréquence de mesure élevée (temps réel) souvent incompatible avec les techniques actuelles. Une solution analytique couplant un four et un spectromètre de masse haute résolution associé à une méthode d’ionisation chimique contrôlée a été développée. Celle-ci est basée sur un spectromètre FT-ICR compact à bas champ magnétique : BTrap. Les points forts de cette technique sont la très haute résolution en masse qui permet de mesurer la masse exacte des composés et la détection multi composés, simultanée sur toute la gamme de masse. L’ionisation chimique contrôlée permet l'ionisation douce et quantitative des molécules d’intérêt. Le transfert de proton à partir de l’ion H₃O⁺ (PTRMS) a montré son potentiel pour la détection des COV dans de nombreux domaines. Après une présentation du contexte et du besoin, le dispositif expérimental développé est détaillé. La validation de celui-ci pour l'analyse de gaz traces a été effectuée au LPGP, sur un système de dépollution par plasma froid. Les résultats de dégradation de l'acétaldéhyde en fonction des conditions de fonctionnement du réacteur sont présentés.L’ionisation par PTR conduit habituellement à la molécule protonée ce qui simplifie l’identification. Cependant des fragmentations peuvent être observées. L’utilisation d’un précurseur d’ionisation chimique plus lourd et moins réactif que H₃O⁺ pourrait minimiser ces phénomènes. L’utilisation du diflurobenzène protoné a été testée et comparée à celle de l’ion H₃O⁺. Pour cela, des études cinétiques ont été menées sur une série d’alcools connus pour fragmenter avec H₃O⁺, et confirment l'intérêt du nouveau précurseur.Le poly(méthacrylate de méthyle) (PMMA) est un matériau très répandu : plexiglass. Sa dégradation est a priori relativement simple puisqu’il s’agit très majoritairement d’une dépolymérisation, accompagnée de la formation de produits minoritaires. En conséquence, son étude nous a paru intéressante pour la mise au point et la validation de la méthode. La dégradation du PMMA a été étudiée sous atmosphère inerte, puis oxydante. Les résultats obtenus sont présentés : produits émis, bilan en masse, et apport du suivi en temps réel de la dégradation, montrant en particulier que les produits minoritaires sont émis après le monomère.Enfin une dernière partie de conclusion présente les perspectives pour cette nouvelle méthode. / Polymeric materials are now ubiquitous in our environment and become irreplaceable for many applications such as packaging, textile or furniture. Knowledge of the life cycle of these materials from production to destruction becomes important for our societies. For instance, plastics may release Volatile Organic Compounds: VOCs are often toxic and their impact on the environment must be evaluated. The aim of this thesis work is the development of a laboratory method for identification and quantification of these emissions. The difficulty arises from the wide variety of compounds being potentially emitted. Moreover the desired method requires a high measurement rate ("real time") often incompatible with existing techniques. An analytical device coupling a furnace and a high-resolution mass spectrometer associated with a controlled chemical ionization method has been developed. This device is based on a low magnetic field FT-ICR compact mass spectrometer. The strengths of this technique are (i) high mass resolution allowing exact mass measurements, (ii) recording of the whole mass range simultaneously, allowing detection of a large variety of compounds. Controlled chemical ionization allows soft and quantitative ionization of molecules of interest. Proton transfer from H₃O⁺ ion (PTRMS) has shown its potentialities for VOC detection in many areas. After presenting the background and need, the developed experimental device is described in detail.The validation of this instrument for trace gas analysis has been performed at LPGP, using a nonthermal plasma depollution device. The results of acetaldehyde degradation according to operating conditions in the discharge reactor are presented.PTR ionization usually leads to the protonated molecule, so that identification is simplified. However fragmentations are sometimes observed. Use of a chemical ionization precursor ion heavier and less reactive than H₃O⁺ may minimize these drawbacks. Protonated difluorobenzene was selected as a precursor and its reactivity was tested and compared with H3O+ reactivity. In this purpose, kinetic studies were performed on a series of alcohols known for their fragmentation behavior with H₃O⁺. The results confirm the interest of the new precursor.Polymethyl methacrylate (PMMA) is a widespread material: plexiglass. Its degradation process is relatively simple since it consists in predominant depolymerization, along with formation of minor products. Consequently, PMMA study appeared interesting for method development and validation. Thermal degradation of PMMA has been studied under inert, then oxidative atmosphere conditions. The presented results include identification of minor products and mass balance under different temperature conditions. Real-time monitoring of VOC emission showed time differences in emission peaks of MMA monomer and minor products, each of them being emitted slightly later than MMA. Finally, a conclusive part presents the perspectives opened for this new method.
3

Surgical tools localization in 3D ultrasound images / Localisation d'outils thérapeutiques de forme linéaire par imagerie ultrasonore 3D

Uhercik, Marian 20 April 2011 (has links)
Cette thèse traite de la détection automatique d’outils chirurgicaux de géométrie linéaire tels que des aiguilles ou des électrodes en imagerie ultrasonore 3D. Une localisation précise et fiable est nécessaire pour des interventions telles que des biopsies ou l’insertion d’électrode dans les tissus afin d’enregistrer leur activité électrique (par exemple dans le cortex cérébral). Le lecteur est introduit aux bases de l’imagerie ultrasonore (US) médicale. L’état de l’art des méthodes de localisation est rapporté. Un grand nombre de méthodes sont basées sur la projection comme la transformation de Hough ou la Projection Intégrale Parallèle (PIP). Afin d’améliorer l’implantation des méthodes PIP connues pour être assez lentes, nous décrivons une possible accélération par approche multirésolution. Nous proposons d’utiliser une méthode d’ajustement de modèle utilisant une approche RANSAC et une optimization locale. C’est une méthode rapide permettant un traitement temps réel et qui a l’avantage d’être très robuste en présence d’autres structures fortement échogènes dans le milieu environnant. Nous proposons deux nouveaux modèles d’apparence et de forme de l’outil dans les images US 3D. La localisation de l’outil peut être améliorée en exploitant son aspect tubulaire. Nous proposons un modèle d’outil utilisant un filtrage rehausseur de ligne que nous avons incorporé dans le schéma de recherche de modèle. La robustesse de cet algorithme de localisation est améliorée au prix d’un temps additionnel de pré-traitement. La localisation temps-réel utilisant le modèle de forme est démontrée par une implantation sur l’échographe Ultrasonix RP. Toutes les méthodes proposées on été testée sur des données de simulation US, des données de fantômes (qui sont des tissus synthétiques imitant les tissus biologiques) ainsi que sur des données réelles de biopsie du sein. Les méthodes proposées ont montré leur capacité à produire des résultats similaires en terme de précision mais en limitant d’avantage le nombre d’échecs de détection par rapport aux méthodes de l’état de l’art basées sur les projections. / This thesis deals with automatic localization of thin surgical tools such as needles or electrodes in 3D ultrasound images. The precise and reliable localization is important for medical interventions such as needle biopsy or electrode insertion into tissue. The reader is introduced to basics of medical ultrasound (US) imaging. The state of the art localization methods are reviewed in the work. Many methods such as Hough transform (HT) or Parallel Integral Projection (PIP) are based on projections. As the existing PIP implementations are relatively slow, we suggest an acceleration by using a multiresolution approach. We propose to use model fitting approach which uses randomized sample consensus (RANSAC) and local optimization. It is a fast method suitable for real-time use and it is robust with respect to the presence of other high-intensity structures in the background. We propose two new shape and appearance models of tool in 3D US images. Tool localization can be improved by exploiting its tubularity. We propose a tool model which uses line filtering and we incorporated it into the model fitting scheme. The robustness of such localization algorithm is improved at the expense of additional time for pre-processing. The real-time localization using the shape model is demonstrated by implementation on the 3D US scanner Ultrasonix RP. All proposed methods were tested on simulated data, phantom US data (a replacement for a tissue) and real tissue US data of breast with biopsy needle. The proposed methods had comparable accuracy and the lower number of failures than the state of the art projection based methods.

Page generated in 0.1108 seconds