• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • Tagged with
  • 8
  • 8
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Emprego da amostragem de suspensão na determinação de metais em amostras antarticas e de sedimento de rio por espectrometria de absorção atomica com chama

Alves, Flavia de Lima 28 July 2018 (has links)
Orientadores : Marco Aurelio Zezzi Arruda, Wilson de Figueiredo Jardim / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-07-28T20:16:29Z (GMT). No. of bitstreams: 1 Alves_FlaviadeLima_D.pdf: 3646555 bytes, checksum: 0237a9bd851e3931e84847287192991c (MD5) Previous issue date: 2001 / Doutorado
2

Estudo da lixiviação bacteriana de metais presentes em lodo de esgoto sanitário /

Villar, Luciene Dias January 2003 (has links)
Orientador: Oswaldo Garcia Junior / Banca: Íria Fernandes Vendrame / Banca: João Sérgio Cordeiro / Banca: Rosana Filomena Vazoller / Banca: Maria Lucia Gonsales da Costa Araujo / Resumo: A geração de lodo como resultado do tratamento do esgoto sanitário, embora possa ser minimizada, é inevitável, qualquer que seja o sistema empregado nas estações de tratamento. Sua disposição final tem sido motivo de diversos estudos, os quais apontam, como alternativa mais favorável, sua utilização em áreas agrícolas ou de produção florestal. A presença de metais no lodo, entretanto, pode inviabilizar seu uso como fertilizante ou como condicionador de solos dado ao risco de contaminação ambiental e de acumulação na cadeia trófica. A solubilização de metais presentes no lodo por meio do processo de lixiviação bacteriana tem mostrado resultados promissores, encorajando seu desenvolvimento. A lixiviação bacteriana de metais pode ocorrer diretamente, pela oxidação de sulfetos metálicos ou, indiretamente, pela oxidação de compostos reduzidos de enxofre a sulfato, com a conseqüente solubilização ácida dos metais. As principais bactérias envolvidas nesse processo pertencem ao gênero Thiobacillus, recentemente reclassificado. Neste trabalho, utilizou-se lodo de esgoto, gerado pela Estação de Tratamento de Esgoto de Franca-SP (ETE-Franca), que opera um sistema de lodos ativados convencional, com tratamento dos lodos primário e secundário por digestão anaeróbia. Amostras de lodo foram caracterizadas quanto à presença dos metais cromo, cobre, chumbo, níquel e zinco. Em um ensaio preliminar, utilizando a linhagem Acidithiobacillus thiooxidans FG01, foi verificado que a utilização de lodo digerido ou lodo não-digerido proporcionou eficiências de solubilização similares para os metais investigados. Desta forma, amostras de lodo digerido anaeróbio foram utilizadas para estudo do efeito dos parâmetros temperatura, pH inicial e concentração de sólidos totais sobre a eficiência e a cinética da lixiviação bacteriana. Nesses ensaios,...(Resumo completo clicar acesso eletrônico abaixo) / Abstract: Although sewage sludge generation from sanitary wastewater treatment can be minimized, its production cannot be avoided at any system employed in the wastewater treatment facilities. Sludge final disposal has motivated several research studies, which have pointed out as the most suitable alternative the application of sludge in agricultural and forestry production. However, the presence of metals in sewage sludge may jeopardize its application as fertilizer or soil amendment due to the risk of environmental contamination or accumulation through the trophic chain. Solubilization of metals from sewage sludge by bacterial leaching has showed promising results, encouraging its process development. Bacterial leaching of metals occurs directly by metal sulphide oxidation or, indirectly by oxidation of reduced sulphur compounds to sulphate, with the consequent sludge acidification and metal solubilization. Bacteria from Thiobacillus genus, recently reclassified, are the most important species involved in bacterial leaching. In this work, sludge samples were obtained at the municipal wastewater treatment facility in the city of Franca, state of São Paulo, Brazil, which operates a conventional activated sludge system with treatment of the primary and secondary sewage sludges by anaerobic digestion. Samples were characterized for concentration of the metals chromium, copper, lead, nickel, and zinc. A preliminary assay was conducted by using Acidithiobacillus thiooxidans FG01, which resulted in similar solubilization efficiencies for digested or not-digested sludges. Effects of temperature, initial pH and total solids concentration were investigated in leaching experiments using anaerobically digested sludge inoculated...(Complete abstract, click electronic access below) / Doutor
3

Estudo da lixiviação bacteriana de metais presentes em lodo de esgoto sanitário

Villar, Luciene Dias [UNESP] 03 July 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:00Z (GMT). No. of bitstreams: 0 Previous issue date: 2003-07-03Bitstream added on 2014-06-13T18:41:24Z : No. of bitstreams: 1 villar_ld_dr_araiq.pdf: 1587723 bytes, checksum: 57434b492ceade6788c279ec21c41b1f (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A geração de lodo como resultado do tratamento do esgoto sanitário, embora possa ser minimizada, é inevitável, qualquer que seja o sistema empregado nas estações de tratamento. Sua disposição final tem sido motivo de diversos estudos, os quais apontam, como alternativa mais favorável, sua utilização em áreas agrícolas ou de produção florestal. A presença de metais no lodo, entretanto, pode inviabilizar seu uso como fertilizante ou como condicionador de solos dado ao risco de contaminação ambiental e de acumulação na cadeia trófica. A solubilização de metais presentes no lodo por meio do processo de lixiviação bacteriana tem mostrado resultados promissores, encorajando seu desenvolvimento. A lixiviação bacteriana de metais pode ocorrer diretamente, pela oxidação de sulfetos metálicos ou, indiretamente, pela oxidação de compostos reduzidos de enxofre a sulfato, com a conseqüente solubilização ácida dos metais. As principais bactérias envolvidas nesse processo pertencem ao gênero Thiobacillus, recentemente reclassificado. Neste trabalho, utilizou-se lodo de esgoto, gerado pela Estação de Tratamento de Esgoto de Franca-SP (ETE-Franca), que opera um sistema de lodos ativados convencional, com tratamento dos lodos primário e secundário por digestão anaeróbia. Amostras de lodo foram caracterizadas quanto à presença dos metais cromo, cobre, chumbo, níquel e zinco. Em um ensaio preliminar, utilizando a linhagem Acidithiobacillus thiooxidans FG01, foi verificado que a utilização de lodo digerido ou lodo não-digerido proporcionou eficiências de solubilização similares para os metais investigados. Desta forma, amostras de lodo digerido anaeróbio foram utilizadas para estudo do efeito dos parâmetros temperatura, pH inicial e concentração de sólidos totais sobre a eficiência e a cinética da lixiviação bacteriana. Nesses ensaios,... / Although sewage sludge generation from sanitary wastewater treatment can be minimized, its production cannot be avoided at any system employed in the wastewater treatment facilities. Sludge final disposal has motivated several research studies, which have pointed out as the most suitable alternative the application of sludge in agricultural and forestry production. However, the presence of metals in sewage sludge may jeopardize its application as fertilizer or soil amendment due to the risk of environmental contamination or accumulation through the trophic chain. Solubilization of metals from sewage sludge by bacterial leaching has showed promising results, encouraging its process development. Bacterial leaching of metals occurs directly by metal sulphide oxidation or, indirectly by oxidation of reduced sulphur compounds to sulphate, with the consequent sludge acidification and metal solubilization. Bacteria from Thiobacillus genus, recently reclassified, are the most important species involved in bacterial leaching. In this work, sludge samples were obtained at the municipal wastewater treatment facility in the city of Franca, state of São Paulo, Brazil, which operates a conventional activated sludge system with treatment of the primary and secondary sewage sludges by anaerobic digestion. Samples were characterized for concentration of the metals chromium, copper, lead, nickel, and zinc. A preliminary assay was conducted by using Acidithiobacillus thiooxidans FG01, which resulted in similar solubilization efficiencies for digested or not-digested sludges. Effects of temperature, initial pH and total solids concentration were investigated in leaching experiments using anaerobically digested sludge inoculated...(Complete abstract, click electronic access below)
4

Uso da técnica de difusão em filmes finos por gradientes de concentração (DGT) para determinação in situ de metais-traço nos rios da Bacia Amazônica Central /

Yabuki, Lauren Nozomi Marques. January 2012 (has links)
Orientador: Amauri Antonio Menegário / Banca: Fabiano Tomazini da Conceição / Banca: Domitila Pascoaloto / Resumo: Este projeto tem como principal objetivo avaliar a eficiência da técnica de difusão em filmes finos por gradientes de concentração (DGT) para a determinação da fração lábil de metais em águas da bacia Amazônica. Em decorrência da complexidade do uso da DGT, especificamente para algumas amostras da região amazônica (baixa força iônica e alto teor de matéria orgânica) foi desenvolvido um novo procedimento analítico. O procedimento é baseado na calibração em laboratório dos dispositivos DGT especificamente para alguns dos principais rios da bacia Amazônica Central (Negro, Solimões e Amazonas), medindo o coeficiente de difusão aparente de alguns metais. Foi avaliada a adequabilidade deste procedimento fazendo a determinação in situ de alumínio, cádmio, chumbo, cobalto, cobre, manganês, níquel e zinco. Também poderá ser avaliado o emprego de géis com diferentes porosidades para alumínio e cobre / Abstract: The main purpose of this project is to evaluate the effectiveness of diffusive gradients in thin films technique (DGT) for determination of fraction of labile metals in waters of the Amazon basin. Because of the complexity of the use of DGT, specifically for some samples of the Amazon region (low ionic strength and high organic matter content) has been developed a new analytical procedure. The procedure is based on the determination of an apparent diffusion coefficient (Dap) in laboratory by deployments in a similar matrix to that site of study (major rivers of the Amazon Central basin - Negro, Solimões and Amazonas). The Dap determined is then used for in situ measurements. It was evaluated the suitability of this procedure by the in situ determination of aluminum, cadmium, lead, cobalt, copper, manganese, nickel and zinc / Mestre
5

Uso da técnica de difusão em filmes finos por gradientes de concentração (DGT) para determinação in situ de metais-traço nos rios da Bacia Amazônica Central

Yabuki, Lauren Nozomi Marques [UNESP] 10 September 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:26:12Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-09-10Bitstream added on 2014-06-13T20:33:59Z : No. of bitstreams: 1 yabuki_lnm_me_rcla.pdf: 1746090 bytes, checksum: 1f8e322cea2379be1cc13bbf1264af6f (MD5) / Este projeto tem como principal objetivo avaliar a eficiência da técnica de difusão em filmes finos por gradientes de concentração (DGT) para a determinação da fração lábil de metais em águas da bacia Amazônica. Em decorrência da complexidade do uso da DGT, especificamente para algumas amostras da região amazônica (baixa força iônica e alto teor de matéria orgânica) foi desenvolvido um novo procedimento analítico. O procedimento é baseado na calibração em laboratório dos dispositivos DGT especificamente para alguns dos principais rios da bacia Amazônica Central (Negro, Solimões e Amazonas), medindo o coeficiente de difusão aparente de alguns metais. Foi avaliada a adequabilidade deste procedimento fazendo a determinação in situ de alumínio, cádmio, chumbo, cobalto, cobre, manganês, níquel e zinco. Também poderá ser avaliado o emprego de géis com diferentes porosidades para alumínio e cobre / The main purpose of this project is to evaluate the effectiveness of diffusive gradients in thin films technique (DGT) for determination of fraction of labile metals in waters of the Amazon basin. Because of the complexity of the use of DGT, specifically for some samples of the Amazon region (low ionic strength and high organic matter content) has been developed a new analytical procedure. The procedure is based on the determination of an apparent diffusion coefficient (Dap) in laboratory by deployments in a similar matrix to that site of study (major rivers of the Amazon Central basin – Negro, Solimões and Amazonas). The Dap determined is then used for in situ measurements. It was evaluated the suitability of this procedure by the in situ determination of aluminum, cadmium, lead, cobalt, copper, manganese, nickel and zinc
6

Determinação multielementar e análise de especiação de vanádio em amostras ambientais da Baía de Todos os Santos, Bahia, Brasil, por técnicas espectrométricas

Santos, Gabriel Luiz dos 05 March 2013 (has links)
Submitted by Ana Hilda Fonseca (anahilda@ufba.br) on 2014-09-05T14:43:24Z No. of bitstreams: 1 Tese de Doutorado Gabriel Luiz dos Santos.pdf: 1820652 bytes, checksum: 813a41cbb9ae01d5c374c54cce45816c (MD5) / Approved for entry into archive by Fatima Cleômenis Botelho Maria (botelho@ufba.br) on 2014-09-05T16:01:28Z (GMT) No. of bitstreams: 1 Tese de Doutorado Gabriel Luiz dos Santos.pdf: 1820652 bytes, checksum: 813a41cbb9ae01d5c374c54cce45816c (MD5) / Made available in DSpace on 2014-09-05T16:01:28Z (GMT). No. of bitstreams: 1 Tese de Doutorado Gabriel Luiz dos Santos.pdf: 1820652 bytes, checksum: 813a41cbb9ae01d5c374c54cce45816c (MD5) / CNPq / O presente trabalho realizado em amostras coletadas na Baía de Todos os Santos, Bahia, Brasil, propõe estratégias para determinação multielementar e análise de especiação de vanádio em amostras de moluscos bivalves e sedimentos, empregando ICP OES e ICP-MS. Na primeira parte da tese, foram avaliadas as potencialidades de dois espectrômetros de massa com plasma indutivamente acoplado para determinação de As, Cr, Ni, Se e V em amostras de moluscos bivalves. Para efeito de comparação, três materiais de referência certificados (CRM) foram analisados: NIST 1566b SRM Oyster tissue, NRCC TORT-2 Lobster Hepatopancreas e NIST 2977 SRM Mussel tissue. A condição recomendada, que consistiu na determinação no modo padrão com adição de padrão interno, foi aplicada na determinação dos analitos em amostras de Macoma constricta coletadas em diferentes regiões da BTS. Os resultados apontaram que a maioria dos níveis de As, Cr, Ni, Se e V presentes na espécie Macoma constricta apresentaram valores acima dos níveis estabelecidos pela legislação vigente brasileira que são: 1,0 (As); 0,1 (Cr); 5,0 (Ni); 0,3 (Se) e 0,77 (V) g g-1 (peso úmido), o que representa risco à população e ao ecossistema. Na segunda parte da tese, foram investigadas as condições para a análise de especiação de vanádio em amostras de sedimentos, empregando extração alcalina e determinação por ICP OES. A concentração de V(IV) foi determinada por diferença, considerando a determinação de vanádio total, também realizada por ICP OES, após digestão das amostras com ácido nítrico em forno de micro- ondas com cavidade, usando o procedimento EPA 3051A. O procedimento foi validado através de testes de adição e recuperação e de análise do seguinte material de referência certificado: NIST 2702 (Inorganics in marine sediment). Pelos resultados obtidos pode-se concluir que os compostos contendo V(IV) são mais dominantes nas amostras dos sedimentos analisados. / The present work conducted on samples collected in Todos os Santos Bay, Bahia, Brasil, proposes strategies for multielement determination and speciation analysis of vanadium in bivalve molluscs and sediments samples, using ICP OES and ICP-MS. In the first part of the thesis, the potential of two inductively coupled plasma mass spectrometers for determination of As, Cr, Ni, Se and V in bivalve molluscs samples were evaluated. For comparison, three certified reference materials (CRM) were analyzed: NIST 1566b SRM Oyster tissue, NRCC TORT-2 Lobster Hepatopancreas e NIST 2977 SRM Mussel tissue. The recommended condition, which consisted in determining the standard mode with addition of internal standard, was applied in the determination of analytes in samples of Macoma constricta collected in different regions of the BTS. The results showed that most levels of As, Cr, Ni, Se and V present in the species Macoma constricta have values above the levels established by the Brazilian legislation, that are: 1.0 (As); 0.1 (Cr); 5.0 (Ni); 0.3 (Se) and 0.77 (V) g g-1 (wet weight), which represents risk to the population and the ecosystem. In the second part of the thesis, the conditions for speciation analysis of vanadium in soil and sediment samples were investigated, using alkaline extraction and determining by ICP OES. The V (IV) concentration was determined by difference, considering the total vanadium determination, also performed by ICP OES, after the samples digestion with nitric acid in cavity microwave oven, using the procedure EPA 3051A. The procedure was validated through addition and recovery tests and analysis of the following certified reference material: NIST 2702 (Inorganics in marine sediment). From the obtained results it can be concluded that compounds containing V (IV) are majority in the sediment samples analyzed.
7

Novos dispositivos de microextração e pré-concentração para eletroforese capilar utilizando membranas microporosas ou processos eletroquímicos e sua potencialidade na análise de aminas e metais / New devices to extraction and preconcentration with microporous membranes and electrochemical procedures prior to capillary electrophoresis: some applications to amines and metals analysis

Antunes Junior, Osmar 13 October 2008 (has links)
A eletroforese capilar (CE) é uma técnica de separação eficiente, que tem merecido grande atenção nas últimas duas décadas, e que oferece soluções analíticas alternativas ou complementares à cromatografia líquida num número crescente campos de aplicação, incluindo análises de fármacos, compostos biológicos e biogênicos, dentre outros. Entre as vantagens comparativas da técnica figuram separações mais rápidas com pequeno dispêndio de amostras, solução tampão (e solvente orgânico, se usado), baixo custo de operação e manutenção. Todavia, a exigüidade de amostra no capilar tem como reflexo, via de regra, limites de detecção menos favoráveis que os da HPLC, uma limitação significativa na análise de traços, suplantável por técnicas e procedimentos de extração/acumulação prévia dos analitos. Nesta tese concebeu-se e implementou-se a combinação inédita entre a CE e a préconcentração eletroquímica de metais. Novos dispositivos para extração líquido/gás/líquido mediada por membranas microporosas também foram propostos e aplicados à analise de aminas voláteis, sempre utilizando detector de condutância medida sem contato direto com a solução (C4D, contactless capacitively coupled conductivity detection). Primeiramente, sem recorrer à preconcentração, definiu-se condições de análise para 16 aminas (metilamina, dimetilamina, trimetilamina, propilamina, n-butilamina, s-butilamina, t-butilamina, hexilamina, DMAE, etanolamina, dietanolamina, trietanolamina, 1,3-diaminopropano, 1,4-diaminobutano, 1,5-diaminopentano e 1,6-diaminohexano) juntamente com íon amônio, e, para análise de 9 metais (TI++, Cd2+, Pb2+,Cr3+, Zn2+, Ag+, Cu2+, Co2+ e Ni2+). Um método completo para análise de dimetilaminoetanol em formulações cosméticas por CE-C4D foi desenvolvido e validado. Os estudos de extração e pré-concentração líquido/gás/líquido foram realizados utilizando filamento oco de Oxyphan preenchido com solução coletora. Foi construída cela para extração gasosa constituída de recipiente fechado no qual se introduz amostra com analitos voláteis, ou volatilizáveis pela adição de reagente e/ou aquecimento (pervaporação). A bobina coletora de filamento oco preenchido com solução coletora foi montada na parte interna da tampa da cela. Testes realizados com amostras de tecidos de peixe demonstraram o funcionamento do sistema, que poderá ser aperfeiçoado e aplicado, por exemplo, à análise de aminas biogênicas primárias de baixo peso molecular, indicadoras de decomposição de certos alimentos. Criou-se também extrator microvolumétrico em que o filamento de Oxyphan é montado concentricamente no interior de um capilar de sílica fundida, para realização de estudos de extração líquido/gás/líquido em fluxo. Um sistema em fluxo compreendendo válvulas e microbombas foi montado e colocado sob controle de um programa de computador (Labview), que, entre outras funções, controla o deslocamento da solução coletora exposta no filamento oco (13 µL) até o ponto exato da interface em que se dá a injeção no capilar da CE. Pela primeira vez recorreu-se à acumulação eletroquímica (ECPC) de analitos num sistema FIA-CE-C4D - uma configuração baseada inteiramente na eletroquímica -, visando expandir os limites de detecção das determinações e eliminar interferência de matriz por troca de meio. Implementou-se a pré-concentração catódica seguida de redissolução anódica com uma célula eletroquímica especial, em que o capilar da eletroforese é posicionado junto ao eletrodo de trabalho, feito de ouro obtido a partir de CD\'s graváveis. Uma célula microfluídica ECPC-FIA-CE-C4D também foi construída. Tomando íons Cu2+ como sistema modelo, demonstrou-se o aumento do sinal referente aos íons cobre(lI) no eletroferograma para tempos crescentes de acumulação eletroquímica. Para a solução de alto teor salino contendo mistura dos íons Cd(II), Pb(II), Zn(lI) e Cu(II), comprovou-se a eliminação da interferência da matriz por troca de meio antes da redissolução anódica. Os testes iniciais indicam que os novos dispositivos e sistemas propostos nesta tese para uso em conjunto com a CE têm potencialidade para desencadear novas pesquisas, desenvolvimento de métodos e aplicações, sendo passíveis também de miniaturização e automação. / Capillary electrophoresis (CE) is an efficient separation technique that evolved rapidly in the last couple of decades, now offering complementary or alternative analytical solutions to liquid chromatography for an expanding number of application fields including drugs, biological and biogenic compounds. Some comparative advantages of CE are faster separation, very low consumption of buffer solutions and samples (and organic solvents, if any), lower maintenance and operational costs. However, the quantification of a few nanoliters of analyte in a capillary, as a rule, compromises the detection limits attainable by HPLC, a shortcomming in trace analysis, suplantable by extraction/preconcentration of the analytes from the sample. The combination of electrochemical preconcentration (ECPC) with CE is first proposed in this thesis and tested with metal ions. New devices for liquid/gas/liquid extraction based on microporous filaments filled with a collector solution were proposed and applied to the analysis of volatile amines, The detector of choice was the C4D (capacitively coupled contactless conductivity detection) and CE-C4D working conditions were defined for the separation and determination of: i) 16 amines (methylamine, dimethylamine, trimethylamine, propylamine, n-butylamine, s-butylamine, t-butylamine, hexilamine, ethanolamine, diethanolamine, triethanolamine, DMAE, 1,3-diaminopropane, 1,4- diaminobutane, 1,5-diaminopentane and 1,6-diaminohexane) plus ammonium, ii) nine metallic ions (Tl+, Cd2+, Pb2+, Cr3+ Zn2+, Ag+, Cu2+, Co2+ e Ni2+). A complete method of analysis for Dimethyl-amino-ethanol (DMAE) in cosmetic formulations was established and validated. Liquid/gas/liquid extraction studies were based on the use of a polypropylene microporous filment (Oxyphan® ) filled with the collection solution. A closed cell was devised in which an Oxyphan® coil is installed beneath the cap and volatilization of sample components can be promoted by heating (pervaporation) or addition of a reactant. The device was successfully tested with fish samples by the detection of primary low molecular weight biogenic amines, a procedure of special interest in fast checking of fish or other foods for decomposition. A microvolumetric version of the liquid/gas/liquid extractor was created with an Oxyphan® hollow fiber mounted concentrically inside a silica capillary. A flow system comprising the micropumps, solenoid valves and the microextrator was designed, automatically operated under software control (Labview). This FIA-CE system was tested by the extraction/enrichment of volatile amines in the collecting solution (13 µL) followed by accurate displacement to the interface with the CE capillary by the micropumps. Pioneering work with ECPC-FIA-CE-C4D an all-electrochemical system was conducted in this thesis aiming expanded detection limits and matrix effect reduction. An electrochemical cell for the interface with FIA-CE system was built in acrylic using gold electrodes made from gold-sputtered CD-Rs. A microfluidic version of the cell interfaced with the CE capillary was also conceived. The full system was evaluated by using Cu2+ as a model specie; an increase in analytical signal was observed as a function of the cathodic deposition time before stripping. For a mixture of Cd2+, Cu2+, Zn2+ and Pb2+ in a high saline media, elimination of the matrix interference by medium exchange before stripping was demonstrated. Initial favorable evaluations show that the devices and systems proposed in 12 the thesis have the potential to engender further research of methods and applications as well as miniaturization and automation of procedures.
8

Novos dispositivos de microextração e pré-concentração para eletroforese capilar utilizando membranas microporosas ou processos eletroquímicos e sua potencialidade na análise de aminas e metais / New devices to extraction and preconcentration with microporous membranes and electrochemical procedures prior to capillary electrophoresis: some applications to amines and metals analysis

Osmar Antunes Junior 13 October 2008 (has links)
A eletroforese capilar (CE) é uma técnica de separação eficiente, que tem merecido grande atenção nas últimas duas décadas, e que oferece soluções analíticas alternativas ou complementares à cromatografia líquida num número crescente campos de aplicação, incluindo análises de fármacos, compostos biológicos e biogênicos, dentre outros. Entre as vantagens comparativas da técnica figuram separações mais rápidas com pequeno dispêndio de amostras, solução tampão (e solvente orgânico, se usado), baixo custo de operação e manutenção. Todavia, a exigüidade de amostra no capilar tem como reflexo, via de regra, limites de detecção menos favoráveis que os da HPLC, uma limitação significativa na análise de traços, suplantável por técnicas e procedimentos de extração/acumulação prévia dos analitos. Nesta tese concebeu-se e implementou-se a combinação inédita entre a CE e a préconcentração eletroquímica de metais. Novos dispositivos para extração líquido/gás/líquido mediada por membranas microporosas também foram propostos e aplicados à analise de aminas voláteis, sempre utilizando detector de condutância medida sem contato direto com a solução (C4D, contactless capacitively coupled conductivity detection). Primeiramente, sem recorrer à preconcentração, definiu-se condições de análise para 16 aminas (metilamina, dimetilamina, trimetilamina, propilamina, n-butilamina, s-butilamina, t-butilamina, hexilamina, DMAE, etanolamina, dietanolamina, trietanolamina, 1,3-diaminopropano, 1,4-diaminobutano, 1,5-diaminopentano e 1,6-diaminohexano) juntamente com íon amônio, e, para análise de 9 metais (TI++, Cd2+, Pb2+,Cr3+, Zn2+, Ag+, Cu2+, Co2+ e Ni2+). Um método completo para análise de dimetilaminoetanol em formulações cosméticas por CE-C4D foi desenvolvido e validado. Os estudos de extração e pré-concentração líquido/gás/líquido foram realizados utilizando filamento oco de Oxyphan preenchido com solução coletora. Foi construída cela para extração gasosa constituída de recipiente fechado no qual se introduz amostra com analitos voláteis, ou volatilizáveis pela adição de reagente e/ou aquecimento (pervaporação). A bobina coletora de filamento oco preenchido com solução coletora foi montada na parte interna da tampa da cela. Testes realizados com amostras de tecidos de peixe demonstraram o funcionamento do sistema, que poderá ser aperfeiçoado e aplicado, por exemplo, à análise de aminas biogênicas primárias de baixo peso molecular, indicadoras de decomposição de certos alimentos. Criou-se também extrator microvolumétrico em que o filamento de Oxyphan é montado concentricamente no interior de um capilar de sílica fundida, para realização de estudos de extração líquido/gás/líquido em fluxo. Um sistema em fluxo compreendendo válvulas e microbombas foi montado e colocado sob controle de um programa de computador (Labview), que, entre outras funções, controla o deslocamento da solução coletora exposta no filamento oco (13 µL) até o ponto exato da interface em que se dá a injeção no capilar da CE. Pela primeira vez recorreu-se à acumulação eletroquímica (ECPC) de analitos num sistema FIA-CE-C4D - uma configuração baseada inteiramente na eletroquímica -, visando expandir os limites de detecção das determinações e eliminar interferência de matriz por troca de meio. Implementou-se a pré-concentração catódica seguida de redissolução anódica com uma célula eletroquímica especial, em que o capilar da eletroforese é posicionado junto ao eletrodo de trabalho, feito de ouro obtido a partir de CD\'s graváveis. Uma célula microfluídica ECPC-FIA-CE-C4D também foi construída. Tomando íons Cu2+ como sistema modelo, demonstrou-se o aumento do sinal referente aos íons cobre(lI) no eletroferograma para tempos crescentes de acumulação eletroquímica. Para a solução de alto teor salino contendo mistura dos íons Cd(II), Pb(II), Zn(lI) e Cu(II), comprovou-se a eliminação da interferência da matriz por troca de meio antes da redissolução anódica. Os testes iniciais indicam que os novos dispositivos e sistemas propostos nesta tese para uso em conjunto com a CE têm potencialidade para desencadear novas pesquisas, desenvolvimento de métodos e aplicações, sendo passíveis também de miniaturização e automação. / Capillary electrophoresis (CE) is an efficient separation technique that evolved rapidly in the last couple of decades, now offering complementary or alternative analytical solutions to liquid chromatography for an expanding number of application fields including drugs, biological and biogenic compounds. Some comparative advantages of CE are faster separation, very low consumption of buffer solutions and samples (and organic solvents, if any), lower maintenance and operational costs. However, the quantification of a few nanoliters of analyte in a capillary, as a rule, compromises the detection limits attainable by HPLC, a shortcomming in trace analysis, suplantable by extraction/preconcentration of the analytes from the sample. The combination of electrochemical preconcentration (ECPC) with CE is first proposed in this thesis and tested with metal ions. New devices for liquid/gas/liquid extraction based on microporous filaments filled with a collector solution were proposed and applied to the analysis of volatile amines, The detector of choice was the C4D (capacitively coupled contactless conductivity detection) and CE-C4D working conditions were defined for the separation and determination of: i) 16 amines (methylamine, dimethylamine, trimethylamine, propylamine, n-butylamine, s-butylamine, t-butylamine, hexilamine, ethanolamine, diethanolamine, triethanolamine, DMAE, 1,3-diaminopropane, 1,4- diaminobutane, 1,5-diaminopentane and 1,6-diaminohexane) plus ammonium, ii) nine metallic ions (Tl+, Cd2+, Pb2+, Cr3+ Zn2+, Ag+, Cu2+, Co2+ e Ni2+). A complete method of analysis for Dimethyl-amino-ethanol (DMAE) in cosmetic formulations was established and validated. Liquid/gas/liquid extraction studies were based on the use of a polypropylene microporous filment (Oxyphan® ) filled with the collection solution. A closed cell was devised in which an Oxyphan® coil is installed beneath the cap and volatilization of sample components can be promoted by heating (pervaporation) or addition of a reactant. The device was successfully tested with fish samples by the detection of primary low molecular weight biogenic amines, a procedure of special interest in fast checking of fish or other foods for decomposition. A microvolumetric version of the liquid/gas/liquid extractor was created with an Oxyphan® hollow fiber mounted concentrically inside a silica capillary. A flow system comprising the micropumps, solenoid valves and the microextrator was designed, automatically operated under software control (Labview). This FIA-CE system was tested by the extraction/enrichment of volatile amines in the collecting solution (13 µL) followed by accurate displacement to the interface with the CE capillary by the micropumps. Pioneering work with ECPC-FIA-CE-C4D an all-electrochemical system was conducted in this thesis aiming expanded detection limits and matrix effect reduction. An electrochemical cell for the interface with FIA-CE system was built in acrylic using gold electrodes made from gold-sputtered CD-Rs. A microfluidic version of the cell interfaced with the CE capillary was also conceived. The full system was evaluated by using Cu2+ as a model specie; an increase in analytical signal was observed as a function of the cathodic deposition time before stripping. For a mixture of Cd2+, Cu2+, Zn2+ and Pb2+ in a high saline media, elimination of the matrix interference by medium exchange before stripping was demonstrated. Initial favorable evaluations show that the devices and systems proposed in 12 the thesis have the potential to engender further research of methods and applications as well as miniaturization and automation of procedures.

Page generated in 0.13 seconds