• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 19
  • 8
  • 8
  • 8
  • 8
  • 7
  • 2
  • 1
  • Tagged with
  • 20
  • 20
  • 11
  • 9
  • 7
  • 7
  • 7
  • 5
  • 5
  • 5
  • 4
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Avaliação da osteointegração em implantes da liga de Tii7,5Mo com tratamento de superfície por anodização /

Tupinambá, Rogerio Amaral. January 2019 (has links)
Orientador: Ana Paula Risifni Alves Claro / Coorientador: Ana Lúcia do Amaral Escada / Banca: Durval Rodrigues Júnior / Banca: Cristiane Aparecida Assis Claro / Banca: Ronaldo Spezia Nunes / Resumo: O objetivo deste estudo in vivo foi avaliar as propriedades de resposta óssea da liga de Ti7,5Mo usinada em minimplantes com tratamento de superfície por anodização e compara-la, com sua versão não tratada e com a liga de Ti-CP em sua apresentação comercial, tratada por jateamento e ataque ácido, em relação às suas propriedades de osteointegração. Os minimplantes do Grupo tratado de Ti7,5Mo foram anodizados em eletrólito de NH4F por 24h e em seguida calcinados a 450ºC por 1h. As amostras foram divididas em três Grupos, Ti-CP com tratamento de superfície por jateamento seguido de ataque ácido (n=5), Ti7,5Mo usinadas (n=5) e Ti7,5Mo anodizado para crescimento de nanotubos de TiO2 (n=6). Para caracterização das amostras foram realizados a espectroscopia Raman, difração de raios X, perfilometria ótica e microscopia eletrônica de varredura. As análises histomorfométricas para determinação do BIC (bone to implant contact) e do BAFO (bone area fraction occupancy) foram realizadas após implantação das amostras de cada Grupo na tíbia de ratos Wistar sacrificados após 4 semanas. A análise estatística por meio do teste de ANOVA de 1 fator demonstrou haver diferença estatística significante apenas entre os Grupos para o BIC; o teste Tukey para avaliação do BIC demonstrou haver diferença estatística significante somente entre o Grupo Ti7,5Mo anodizado em relação ao Grupo Ti-CP em apresentação comercial; não foram detectadas diferenças estatísticas significantes para o BAFO entre os Grupos... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The objective of this in vivo study was to evaluate the bone response of the Ti7,5Mo alloy machined in minimplants with surface treatment by anodization and compare it, with its untreated version and with the Ti-CP alloy in its commercial presentation, gritblasted and acid-etched. The Ti7,5Mo minimplants of the treated group were anodised in a NH4F electrolyte for 24h and then calcinated at 450ºC for 1h. The samples were divided into three groups, Ti-CP with surface treatment by blasting followed by acid-etched (n=5), Ti7, 5Mo machined (n=5) and Ti7, 5Mo anodized for growth of TiO2 nanotubes (n=6). To characterize the samples, Raman spectroscopy, X-ray diffraction, optical perfilometry and scanning electron microscopy (SEM) were performed. The Histomorphometric analysis for determination of the BIC (bone to implant contact) and BAFO (bone area fraction occupancy) were performed after the tibia implantation of the samples of each group in Wistar rats sacrificed after 4 weeks. The statistical analysis using the 1-factor ANOVA test showed statistically significant difference only for BIC amongst groups, Turkey test showed statistically significant difference for the evaluation of BIC only between the group Ti7, 5Mo anodized in relation to the Ti-CP group in commercial presentation, Turkey test did not detect significant statistical difference for BAFO among the groups. Pearson test did not detect direct correlation between BIC and BAFO values. The Ti7,5Mo samples with anodised s... (Complete abstract click electronic access below) / Doutor
12

Modificação da superfície da liga experimental Ti10Mo8Nb empregando oxidação anódica : estudos in vitro /

Carobolante, João Pedro Aquiles. January 2017 (has links)
Orientador: Ana Paula Rosifini Alves Claro / Banca: Claudia Eliana Bruno Marino / Banca: Carlos Roberto Grandini / Resumo: Titânio e suas ligas são amplamente empregados em aplicações biomédicas, devido a sua biocompatibilidade e excelentes propriedades de volume, como resistência mecânica. As ligas de titânio tipo β com baixo módulo de elasticidade, como Ti10Mo8Nb, são indicadas para amenizar o efeito "stress shielding", característico da interface implante/osso. No entanto, quando materiais bioinertes são inseridos no corpo humano não induzirão uma resposta específica. As técnicas de modificação de superfície, como crescimento de nanoestruturas de TiO2, são utilizadas para alterar as propriedades de superfície desses materiais permitindo melhor resposta. O objetivo dessa pesquisa é a modificação de superfície da liga experimental Ti10Mo8Nb a partir do crescimento de nanoestruturas de TiO2. Os lingotes da liga experimental Ti10Mo8Nb foram obtidos a partir da fusão dos metais puros em forno a arco voltaico. A oxidação anódica potenciostática foi realizada utilizando um eletrólito formado por glicerina e H2O (1:1, em vol.) com adição de 2,7 % (m/v) de NH4F sob 20 V durante 3 h, a temperatura ambiente. Após o tratamento as amostras foram calcinadas. A superfície da liga foi analisada por microscopia eletrônica de varredura (MEV), difração de raios X (DRX), ângulo de contato, medidas da energia de superfície, espectroscopia de raios X por dispersão em energia (XPS). Estudos in vitro, como adesão celular e bacteriana, foram realizados para avaliar a resposta desse tratamento. A liga Ti10Mo8Nb apresen... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Titanium and its alloys have been widely used as biomedical material due their biocompatibility and excellent bulk properties, such as mechanical strength. β titanium alloys with low modulus of elasticity, such as Ti10Mo8Nb, are suitable to relieve the stress shielding effect that occurs in the interface implant/bone. However, when these materials are inserted inside human body the surface properties will not induce a specific response. Surface modifications techniques can be used for change the inert surface of these alloys, e.g. TiO2 nanostructure growth by using anodic oxidation. The purpose of this research is the surface modification of Ti10Mo8Nb experimental alloy by using TiO2 nanostruture growth. Ingots of Ti10Mo8Nb experimental alloy were produced by fusion from sheets of molybdenum, niobium and titanium commercially pure in arc melting furnace under argon atmosphere. The potentiostatic anodic oxidation was performed using an electrolyte formed of glycerol and H2O (1: 1 by vol.) with addition of 2.7% (w/v) NH4F under 20 V for 3 h at room temperature. After the surface treatment, the samples were annealing. The surface of the alloy was analyzed by scanning electron microscopy (SEM), X-ray diffraction (XRD), contact angle, surface energy measurements, energy dispersive X-ray spectroscopy (XPS). In vitro studies, such as cell and bacterial adhesion, were performed to evaluate the response of this treatment. The Ti10Mo8Nb alloy exhibited beta phase after the processing, and also occurred a decrease in β-transus temperature. After the surface treatment a nanoporous layer of TiO was obtained. The anatase phase was found in the annealed samples (450 °C for 3 hours). In vitro analyzes showed cell growth viability and decreased bacterial proliferation due to larget specific surface area / Mestre
13

Avaliação do desempenho do óxido de alumínio com tratamento de superfície como dielétrico para capacitores MIS e OFETs /

Silva, Marcelo Marques da. January 2017 (has links)
Orientador: Neri Alves / Banca: Francisco Trivinho Strixino / Banca: Clarissa De Almeida Olivati / Banca: José Alberto Giacometti / Resumo: Foi realizado um estudo sobre as propriedades elétricas de filmes finos de óxido de alumínio (Al2O3) obtidos por anodização em solução eletrolítica preparada com ácido tartárico, etileno glicol e água. Filmes de Al2O3 com espessuras entre 20 e 70 nm foram crescidos sobre camadas de alumínio as quais foram depositadas por evaporação em vácuo sobre lâminas de vidro. Utilizou-se o processo de anodização em duas etapas, sendo que na primeira etapa aplica-se uma corrente constante de 0,48 mA/cm2 e monitora a tensão até alcançar o valor final, programado conforme a espessura desejada; e então, na segunda etapa, mantem-se se a tensão final durante 2 minutos, enquanto mede-se a corrente. Os filmes de Al2O3 apresentam constante dielétrica média de aproximadamente sete (ε = 7), tan δ da ordem de 10-3 e resistividade elétrica da ordem de 1013 cm. Estudou-se o efeito do tratamento de superfície pela a deposição de monocamadas dos silanos, octadecil triclorosilano (OTS), hexametildisilazano (HMDS) e do ácido fosfônico (OPA) nas características elétricas. O tratamento com HMDS se mostrou o mais efetivo, diminuindo a corrente de fuga e aumentando campo de ruptura dielétrica. Também foi estudado o efeito do recobrimento, da superfície dos filmes de Al2O3, com filmes dos polímeros isolantes poliestireno (PS), polivinil álcool (PVA), fluoreto de polivinilideno (PVDF) e polimetilmetacrilato (PMMA). A deposição de um filme de PMMA foi a que apresentou os melhores resultados, c... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: A study about electric properties of aluminum oxide (Al2O3) obtained by anodization of aluminum in a electrolytic solution prepared with tartaric acid, ethylene glycol and water was performed. Thin Al2O3 films from 20 to 70 nm were grown on aluminum layer which were deposited on glass slides by vacuum metallization. It was used the anodization process in two stages, being that in first stage applies a constant current of 0,48 mA/cm2 and monitory the voltage until reach the final value, programmed in according to the desired thickness; and in the second stage, the final voltage is maintained for two minutes, while the current is measured. The Al2O3 films present medium dielectric constant about seven (ε = 7), tan δ in order of 10-3 and resistivity in order of 1013 cm. It was studied the surface treatment effect by monolayers depositions of octadecyl trichlorosilane (OTS), hexamethyldisilazane (HMDS) and phosphonic acid (OPA) on the electrical characteristics. The HMDS treatment proved to be the most effective, reducing the leakage current and increasing the dielectric rupture field. The effect of the addition of polystyrene (PS), polyvinyl alcohol (PVA), polyvinylidene fluoride (PVDF) and polymethylmethacrylate (PMMA) films on the oxide surface was also studied. The deposition of a PMMA film presented the best results, with reduction of the leakage current around two orders of magnitude in relation to pristine oxide. Devices with metal-insulator-semiconducto... (Complete abstract click electronic access below) / Doutor
14

Incorporação de clorexidina na superfície da liga Ti-7,5Mo após o crescimento de nanotubos de TiO2 /

Oliveira, Liliane Lelis de. January 2016 (has links)
Orientador: Ana Paula Rosifini Alves Claro / Coorientadora: Ana Lúcia do Amaral Escada / Banca: Roberto Zenhei Nakazato / Banca: Rodney Bertazzoli / Resumo: O maior desafio no desenvolvimento de materiais para aplicações biomédicas é fazer com que estes tenham uma boa resposta e interação com o meio quando inseridos no corpo. Estudos sobre a topografia de superfície mostram que nanotubos de TiO2 podem contribuir para uma melhor adesão celular pois auxiliam a osseointegração e ancoragem óssea, entretanto essa mesma estrutura de superfície pode induzir o acúmulo e proliferação de bactérias na superfície do implante causando infecções e até mesmo a perda do implante. Nesse trabalho foi estudada a incorporação, ação antibactericida e fungicida da clorexidina na superfície da liga Ti-7,5Mo após o crescimento de nanotubos de TiO2 por oxidação anódica. As amostras foram divididas em dois grupos de acordo com o potencial de anodização de 10V e 20V com tempo de permanência de 24 horas, seguido de calcinação a 450ºC por 1 hora e resfriamento no forno. A partir destes procedimentos foram utilizadas técnicas de caracterização da superfície: Microscopia eletrônica de varredura (MEV) e espectroscopia de energia dispersiva (EDS) para analisar a morfologia da superfície tal como a composição química do filme formado. O ângulo de contato foi medido para analisar a molhabilidade da superfície do material e o ensaio eletroquímico mostrou o comportamento do material em meio SBS. A clorexidina foi incorporada na superfície por imersão por 30 minutos e se mostrou um bom agente bactericida e antifúngico em ação contra S. Aureus e Candida em estudos in ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The challenge when developing materials for biomedical applications is to ensure that they have a good response and interaction when in the body. Studies about the surface topography show that TiO2 nanotubes can bring a better cell adhesion because they help osseointegration and bone anchorage, however, this same surface structure can induce the accumulation and bacteria proliferation in the implant surface causing infections and even loss of the implant. This study brings the incorporation and bactericidal action of chlorhexidine on the surface of Ti-alloy 7,5Mo after growth of TiO2 nanotubes by anodic oxidation. The samples weregrouped according to the anodizing potential of 10V and 20V with time to 24 hours stay, followed by calcination at 450 ° C for 1 hour and cooling into the oven. From these procedures were used as surface characterization techniques: scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS) to examine the surface morphology such as the chemical composition of the film. The contact angle was measured to analyze the surface wettability of the material and the electrochemical assay showed the behavior of the material in the middle of SBS. Chlorhexidine was incorporated into the surface by immersing for 30 minutes and showed a good bactericide and antifungal action against S. Aureus and Candida in vitro. / Mestre
15

Sequenciamento da produção em uma área de tratamento de superfície na indústria aeronáutica /

Schmidt, Paulo Alberto Misfeldt. January 2019 (has links)
Orientador: José Roberto Dale Luche / Coorientador: Aneirson Francisco da Silva / Banca: Fernando Augusto Silva Marins / Banca: Fabricio Maciel Gomes / Resumo: A programação da produção é uma questão muito importante em qualquer empresa de manufatura. Neste trabalho, foi desenvolvido um modelo de programação linear inteira mista para programar a produção de uma área de tratamento de superfície em uma empresa do setor aeronáutico. Uma breve descrição dos processos envolvidos é apresentada. Otimizar o planejamento diário da área de tratamento de superfície não é uma atividade simples, diversas restrições devem ser consideradas no modelo, como o tipo da liga de matéria-prima, a capacidade dos tanques e das gancheiras. Os resultados de planos diários de produção obtidos pelo modelo possuem a combinação ótima de produtos a serem fabricados utilizando os recursos disponíveis em sua capacidade máxima e por consequência aumentando a produtividade da área. Questões técnicas dos processos foram levadas em consideração como restrições uma vez que os produtos foram homologados junto aos fabricantes das aeronaves. Foram realizados experimentos com trinta instâncias reais e outras trinta com demanda acumulada. Os resultados alcançados pelo modelo proposto foram muito superiores quando comparados à prática da empresa, para se ter uma ideia, no período em que foi registrada a menor diferença, o modelo mostra que é possível produzir mais que o dobro do que a empresa produziu com os mesmos recursos, evidenciando que há capacidade produtiva disponível para absorver novos produtos junto aos clientes atuais e futuros / Abstract: Production scheduling is a very important issue in any manufacturing company. In this work, a mixed integer linear programming model was developed to program the production of a surface treatment area in an aeronautical company. A brief description of the processes involved is presented. Optimizing the daily planning of the surface treatment area is not a simple activity, several constraints must be considered in the model, such as the type of raw material alloy, the capacity of the tanks and the glaciers. The results of daily production plans obtained by the model have the optimal combination of products to be manufactured using available resources at their maximum capacity and consequently increasing the area productivity. Technical issues of the processes were taken into consideration as restrictions since the products were homologated with the aircraft manufacturers. Experiments are performed with thirty real instances and another thirty with accumulated demand. The results achieved by the proposed model were much higher when compared to the company's practice, so as to have an idea, in the period when the smallest difference was registered, the model shows that it is possible to produce more than double what the company produced with same resources, showing that there is production capacity available to absorb new products with current and future customers / Mestre
16

Caracterização eletroquímica de filmes anódicos de titânio grau 2 visando aplicações biomédicas /

Torres, Dimas Luiz. January 2013 (has links)
Orientador: Heloisa Andréa Acciari / Coorientador: Eduardo Noberto Codaro / Banca: Rosinei Batista Ribeiro / Banca: Leide Lili Gonçalves da Silva Kostov / Resumo : Diferentes tiposde tratamentos com titânio têm sido propostos com a finalidade de promover o desempenho biológico dos implantes por tornar a superfície bioativa. Muitos metais quando expostos à atmosfera sofrem um processo deoxidação que conduz à formação de uma fina camada de óxidos sobre a sua superfície. Estes produtos da reação podem proteger o metal de posterior corrosão. O processo eletroquímico de anodização de metais permite a obtenção de uma camada de óxido relativamente fina e mais densa que aquela formada naturalmente na atmosfera. No caso do titânio, esta camada tem sido utilizada para favorecer a nucleação de apatitas e, por conseguinte, a osseo integração. Neste estudo foi investigada a influência da concentração do eletrólito e do tempo de anodização na morfologia e no comportamento eletroquímico de filmes anódicos formados sobre titânio comercialmente puro. Métodos eletroquímicos e de análise de superfície foram usados para caracterizar as superfícies modificadas de titânio. Verificou-se que, tanto a concentração doeletrólito como o tempo de anodização afetam o crescimento e as características protetoras dos filmes em um meio que simula o soro fisiológico. Nos perfis potencio dinâmicos, observou-se que os valores dos potenciais de rompimento de filme passivo são afetados pelo tempo de anodização. Variações nos espectros de impedância foram associadas com um aumento no número de defeitos destes filmes / Abstract: Different types of treatments have been proposed with titanium in order to promote the biological performance of implants for making bioactive surface. Many metals when exposed to the atmosphere undergo an oxidation process leading to the formation of a thin oxide layer on its surface. These reaction products can protect the metal from corrosion. The electrochemical process anodizing allows metals to obtain a relatively thin oxide layer and more to denser than formed naturally in the atmosphere. In the case of titanium, this layer has been used to promote nucleation of apatite, and therefore the osseointegração. In this study, it was investigated the influence of electrolyte concentration and the anodizing time on the morphology and electrochemical behavior of anodic films formed on commercially pure titanium. Electrochemical method sand surface analysis were used to characterize the surface modification of titanium. It was found that both the concentration of the electrolyte as anodizing time, affect the growth and protective characteristics of the films in a medium that simulates the physiological serum. In potentiodynamic profiles, it was observed that the values of the potential disruption of the passive film are affected by the time of anodizing. Variations in the impedance spectra were associated with an increase in the number of defects of the films / Mestre
17

Caracterização eletroquímica de filmes anódicos de titânio grau 2 visando aplicações biomédicas

Torres, Dimas Luiz [UNESP] 02 August 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:10Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-08-02Bitstream added on 2014-06-13T20:16:08Z : No. of bitstreams: 1 torres_dl_me_guara.pdf: 1636083 bytes, checksum: 689af8f95c8ac000d7474775ce15c4cc (MD5) / Diferentes tiposde tratamentos com titânio têm sido propostos com a finalidade de promover o desempenho biológico dos implantes por tornar a superfície bioativa. Muitos metais quando expostos à atmosfera sofrem um processo deoxidação que conduz à formação de uma fina camada de óxidos sobre a sua superfície. Estes produtos da reação podem proteger o metal de posterior corrosão. O processo eletroquímico de anodização de metais permite a obtenção de uma camada de óxido relativamente fina e mais densa que aquela formada naturalmente na atmosfera. No caso do titânio, esta camada tem sido utilizada para favorecer a nucleação de apatitas e, por conseguinte, a osseo integração. Neste estudo foi investigada a influência da concentração do eletrólito e do tempo de anodização na morfologia e no comportamento eletroquímico de filmes anódicos formados sobre titânio comercialmente puro. Métodos eletroquímicos e de análise de superfície foram usados para caracterizar as superfícies modificadas de titânio. Verificou-se que, tanto a concentração doeletrólito como o tempo de anodização afetam o crescimento e as características protetoras dos filmes em um meio que simula o soro fisiológico. Nos perfis potencio dinâmicos, observou-se que os valores dos potenciais de rompimento de filme passivo são afetados pelo tempo de anodização. Variações nos espectros de impedância foram associadas com um aumento no número de defeitos destes filmes / Different types of treatments have been proposed with titanium in order to promote the biological performance of implants for making bioactive surface. Many metals when exposed to the atmosphere undergo an oxidation process leading to the formation of a thin oxide layer on its surface. These reaction products can protect the metal from corrosion. The electrochemical process anodizing allows metals to obtain a relatively thin oxide layer and more to denser than formed naturally in the atmosphere. In the case of titanium, this layer has been used to promote nucleation of apatite, and therefore the osseointegração. In this study, it was investigated the influence of electrolyte concentration and the anodizing time on the morphology and electrochemical behavior of anodic films formed on commercially pure titanium. Electrochemical method sand surface analysis were used to characterize the surface modification of titanium. It was found that both the concentration of the electrolyte as anodizing time, affect the growth and protective characteristics of the films in a medium that simulates the physiological serum. In potentiodynamic profiles, it was observed that the values of the potential disruption of the passive film are affected by the time of anodizing. Variations in the impedance spectra were associated with an increase in the number of defects of the films
18

Processos de inversão da magnetização em redes de nanofios magnéticos modulados / Magnetization reversal processes in modulated magnetic nanowire arrays

Costa Arzuza, Luis Carlos, 1983- 31 August 2018 (has links)
Orientadores: Kleber Roberto Pirota, Fanny Béron / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Física Gleb Wataghin / Made available in DSpace on 2018-08-31T01:32:45Z (GMT). No. of bitstreams: 1 CostaArzuza_LuisCarlos_D.pdf: 5838350 bytes, checksum: f92268a1c7835ed7d3d7f0a83abe2e63 (MD5) Previous issue date: 2016 / Resumo: Este trabalho visa estudar a inversão da magnetização de redes de nanofios de níquel modulados, incorporados em membranas porosas de alumina. A modulação do nanofio foi obtida a partir da variação do diâmetro, resultando em nanofios com dois segmentos. O diâmetro de cada segmento está ao redor do diâmetro crítico do Ni (40 nm), onde, abaixo e acima do mesmo, a inversão da magnetização acontece por meio de diferentes estruturas da parede de domínio; transversais e vórtex. A caracterização magnética das redes de nanofios foi feita usando simulações micromagnéticas e curvas de histerese magnética e de reversão de primeira ordem (método FORC). As medidas foram realizadas em vários arranjos de nanofios ordenados com diferentes razões de comprimento e diâmetros de segmentos, e estas foram comparadas com o arranjo de nanofios sem variação do diâmetro. Simulações micromagnéticas em nanofios isolados e arranjo de nanofios de primeiros vizinhos, mostram que a estrutura da parede de domínio, a qual depende do diâmetro do segmento, sofre uma transformação ao cruzar a região da modulação do diâmetro, porém a dinâmica da transformação depende das dimensões de cada segmento do nanofio. O comportamento magnético experimental do arranjo é atribuído a um campo de interação não homogêneo entre os nanofios, o qual surge devido a modulação do diâmetro. Este campo dá origem a uma interação mais forte na extremidade com diâmetro maior em relação à extremidade com diâmetro menor, resultando em um comportamento da susceptibilidade bastante complexo. Consideramos como principal resultado deste trabalho à possibilidade de controlar o mecanismo de inversão da magnetização em rede de nanofios modulados através da modulação do diâmetro. Os resultados obtidos foram interpretados através dos diagramas FORC, onde o processo dinâmico da inversão da magnetização é evidenciado por meio de diagramas estáticos (diagramas FORC), similar a uma foto estroboscópica / Abstract: We studied the magnetization reversal in modulated nickel nanowire arrays, embedded in porous alumina membranes. The modulation of the nanowire was obtained from the variation in diameter, resulting in nanowires with two segments. The diameter of each segment is below and above the critical diameter for Ni (40 nm), for which the reversal of magnetization changes from transversal to vortex domain wall structure. Magnetic characterization of nanowire networks was made using micromagnetic simulations, magnetic hysteresis and First-order reversal curves (FORC method). The measurements were performed in nanowire arrays with different ratios of length and diameter. The results were compared with the arrangement of nanowires without diameter variation. Micromagnetic simulations for isolated nanowires and nanowire array with few magnetic entities show that the structure of domain wall, which depends on the segment diameter, changes when it crosses the separation region of the diameter modulation and the dynamics of transformation depends on the dimensions of each nanowire¿s segment. The experimental magnetic behavior of the nanowire array is attributed to an inhomogeneous interaction field among the nanowires due to diameter modulation. This effect gives rise to a stronger interaction in the larger diameter segment resulting in a very complex susceptibility behavior. We consider the possibility to control the reversal magnetization mechanism in nanowire array through diameter modulation as the main result of this work. The results were interpreted using the FORC diagrams where the dynamic process of magnetization reversal is evidenced by static diagrams (FORC diagrams), similar to a stroboscopic picture / Doutorado / Física / Doutor em Ciências / 1060136/2011 / CAPES
19

Variações morfológicas e estruturais nos filmes de TiO2 formados pela anodização de titânio /

Palma, Dener Pedro da Silva January 2019 (has links)
Orientador: Heloisa Andréa Acciari / Resumo: Nas últimas décadas houve um enorme crescimento do uso titânio comercialmente puro nos mais variados setores da economia como por exemplo na indústria petrolífera, aeroespacial e biomédica. Na indústria biomédica o uso desse metal se caracteriza por ter propriedades mecânicas semelhantes às do osso do corpo humano, por apresentar excelente resistência à corrosão quando comparado com outros metais, e também por ser biocompatível. A biocompatibilidade do titânio ocorre em função da camada de óxido que é formada sobre a superfície deste metal quando exposto a uma atmosfera em que há a presença de oxigênio. Esta camada pode ser amorfa ou cristalina, geralmente quando formada espontaneamente os filmes são amorfos, porém para o uso biomédico é interessante que a fase cristalina anatase se forme sobre a superfície do titânio, pois de acordo com a literatura esta fase favorece a osseointegração. Sendo assim várias técnicas de modificação de superfície, como por exemplo, anodização, tratamento térmico, eletrodeposição, são estudadas para melhorar as propriedades da camada de TiO2. Por tanto, o objetivo desse trabalho foi investigar como os parâmetros de anodização e características de filmes anódicos estão relacionados. Os filmes foram obtidos por anodização em soluções de 0,25 e 2,5 mol L-1 de H3PO4 em três tempos de anodização (3, 6 e 12 horas), comparando dois tipos de substratos: superfícies de titânio eletropolidas e polidas com alumina, com a finalidade de obter uma superfície m... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: In the last decades, there has been a great growth in the use of commercially pure titanium in the most varied sectors of the economy, such as in the aerospace and biomedical industries. In the biomedical industry the use of this metal is due to its properties, such as mechanical strength, which is similar to human bone, as well as its excellent corrosion resistance compared to other metals, and also because of it is a biocompatible element. The biocompatibility of titanium occurs as a function of the oxide layer formed on the surface of this metal when it is exposed to an atmosphere where there is the presence of oxygen. This layer can be amorphous or crystalline, usually when it is formed spontaneously the films are amorphous, but for biomedical use it is interesting that the morphology of the anodic film is composed by the Crystalline phase of the anatase, because according to the literature this phase favors osseointegration. In order to improve the properties of the titanium oxide layer, various surface modification techniques have been studied, such as anodizing, heat treatment and electrodeposition. Thus, the proposal of this work was to investigate how the anodization parameters and the characteristics of anodic films are related. The films were obtained by anodization in 0.25 and 2.5 mol L-1 H3PO4 solutions in three anodization times (3, 6 and 12 hours), comparing two types of substrates: electropolished and non-electropolished titanium surfaces, aimed to create a mo... (Complete abstract click electronic access below) / Mestre
20

Avaliação dos filmes oxidos crescidos anodicamente na liga Ti-6Al-7Nb, pela tecnica de impedancia eletroquimica, para aplicação como biomaterial / Evaluation of anodic oxide films in Ti-6Al-7Nb alloy, through electrochemical impedance technique, to be applied as biomaterial

Kawakami, Kenji 30 August 1996 (has links)
Orientador: Margarita Ballester F. Santos / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-07-22T11:08:57Z (GMT). No. of bitstreams: 1 Kawakami_Kenji_D.pdf: 19175620 bytes, checksum: b6a661ea70e2abc1018ffcac8a295caa (MD5) Previous issue date: 1996 / Resumo: Não informado / Abstract: In this work is developped a procedure for evaluation of oxides films properties. Through Electrochemical Impedance Spectroscopy, by obtaining from Bode diagrams a capacitance and dissipation coefficient. It is proposed a mathematical model for the metal-oxide-eletrolute system description based on na equivalent circuit. The oxide films properties are evaluated by fitting procedure. The technique . is applied to Ti-6AI-7Nb anodized alloys, used as a substitute for Ti-6AI-4Valloy, in surgical aplications. The results show the possibility of film properties evaluation from direct analysis of Bode diagrams / Doutorado / Materiais e Processos de Fabricação / Doutor em Engenharia Mecânica

Page generated in 0.0479 seconds