• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • 5
  • 1
  • 1
  • 1
  • Tagged with
  • 15
  • 15
  • 6
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Microfabrication of Plasmonic Biosensors in CYTOP Integrating a Thin SiO2 Diffusion and Etch-barrier Layer

Hanif, Raza January 2011 (has links)
A novel process for the fabrication of Long Range Surface Plasmon Polariton (LRSPP) waveguide based biosensors is presented herein. The structure of the biosensor is comprised of Au stripe waveguide devices embedded in thick CYTOP claddings with a SiO2 solvent diffusion barrier and etch-stop layer. The SiO2 layer is introduced to improve the end quality of Au waveguide structures, which previously deformed during the deposit of the upper cladding process and to limit the over-etching of CYTOP to create micro-fluidic channels. The E-beam evaporation method is adapted to deposit a thin SiO2 on the bottom cladding of CYTOP. A new micro-fluidic design pattern is introduced. Micro-fluidic channels were created on selective Au waveguides through O2 plasma etching. The presented data and figures are refractive index measurements of different materials, thickness measurements, microscope images, and AFM images. Optical power cutback measurements were performed on fully CYTOP-cladded symmetric LRSPP waveguides. The end-fire coupling method was used to excite LRSPP modes with cleaved polarization maintaining (PM) fibre. The measured mode power attenuation (MPA) was 6.7 dB/mm after using index-matched liquid at input and output fibre-waveguide interfaces. The results were compared with the theoretical calculations and simulations. Poor coupling efficiency and scattering due to the SiO2 are suspected for off-target measurements.
12

Řízení a vyhodnocení laserových mikromanipulačních experimentů / Controlling and Evaluation of Laser Micromanipulation Experiments

Kaňka, Jan January 2012 (has links)
This work is focused on the development of a user friendly software interface using the LabViewTM environment that simplifies running of various experiments using laser micromanipulations and laser microspectroscopy of living microorganisms. Both techniques have been developing very fast for the last decade and belong to the growing group of contact-less and nondestructive techniques for manipulation and diagnostics of individual living microorganisms, cells, or viruses. Within this project we mastered the driving of peripheries, calibration of CCD scene, real-time image processing of the CCD scene, automatic selection of the cell for further laser processing, acquisition and processing of the Raman spectrum from living microorganisms. The final goal of our activity is fully automatic laser-based sorter of living cells depending on their chemical compositions. This work has been elaborated at the Institute of Scientific Instruments of the ASCR, v.v.i. under the supervision of prof. Pavel Zemanek.
13

Effet des films liquides en évaporation / Effect of evaporating liquid films

Chauvet, Fabien 26 November 2009 (has links)
Ce travail est axé sur l'étude de l'évaporation lente d'un liquide confiné dans un tube capillaire de section carrée, en lien avec l'étude du phénomène de séchage. Dans un tel capillaire, si le liquide est suffisamment mouillant, des films liquides se forment par capillarité le long des coins internes. L'évaporation du liquide en sommet de film engendre un pompage capillaire et l'espèce volatile est alors transportée, sous phase liquide, au plus près du sommet du capillaire. Ce mode de transport dépend de la compétition entre les effets capillaires et les effets visqueux et de gravité qui s'opposent tous deux au mouvement du liquide vers le sommet du capillaire. Ces films liquides sont étudiés en adoptant une approche expérimentale. Le principe des expériences est de laisser un liquide volatil s'évaporer dans un tube capillaire carré. Plusieurs expériences d'évaporation sont réalisées en faisant varier la nature du liquide, la taille du capillaire et son orientation (horizontale et verticale). Une méthode de thermographie infra-rouge permet de mesurer le profil de température le long du capillaire. Le refroidissement induit par le changement de phase liquide-vapeur ainsi que sa position sont alors mesurables. A partir d'une méthode de visualisation par ombroscopie, plusieurs grandeurs sont mesurées : position du ménisque principal, taux d'évaporation et épaisseur relative des films. En s'appuyant sur une analyse simple du transfert de masse, on montre alors que les cinétiques d'évaporation obtenues expérimentalement se divisent en trois principales phases caractéristiques, ressemblant fortement aux trois périodes de la cinétique classique de séchage des milieux poreux capillaires. L'analyse de l'hydrodynamique des films montre qu'il est indispensable de prendre en compte l'arrondi interne des coins des capillaires dans la modélisation de l'écoulement au sein des films. On montre notamment que le phénomène étudié est très sensible à ce paramètre, qui limite l'extension des films. Ce travail expérimental a permis de développer une modélisation du transfert de masse dans la configuration étudiée, couplée à une modélisation de l'écoulement des films, et finalement de proposer un modèle de séchage d'un capillaire carré quantitativement satisfaisant. / In connection with the study of the phenomenon of drying, this work focuses on the study of slow evaporation of a liquid confined in a capillary of square cross section. In such a capillary, if the liquid wetting contact angle is low enough, liquid films are trapped by capillary forces along the capillary inside corners. Evaporation of the liquid at the film top creates a capillary pumping. The volatile species is then transported in liquid phase to the top of the capillary. This efficient mode of transport depends on the competition between the effects of capillarity and the effects of viscosity and gravity both opposing to the liquid flow towards the top of the capillary. In this work, the liquid films are studied experimentally.The principle of the experiments is to leave a volatile liquid evaporate in a square capillary tube. Several evaporation experiments are conducted, varying the liquid, the capillary tube size and its orientation (horizontal and vertical). An infrared thermography method allows to measure the temperature profile along the capillary. The cooling induced by the liquid-vapor phase change and its location is then measured. Owing to an ombroscopy visualization method, the location of the bulk meniscus, the evaporation rate and the relative thickness of the films can be measured. The experimental results show that the evaporation kinetics is similar to the drying kinetics of capillary porous media. This finding allows to study evaporation in a square capillary by analogy with the study of drying of capillary porous media. Based on a simple analysis of mass transfer in the system, it is then shown that the evaporation kinetics obtained experimentally can be divided into three main characteristic phases. The analysis of the hydrodynamic of the films shows that it is essential to take into account the roundeness of the capillary tube inside corners in the modelling of the flow in the films. We show that the phenomenon studied is very sensitive to the degree of roundedness of the tube internal corners, which limits the extension of the films. Modelling of the mass transfer coupled with modelling the film flow lead to a quantitatively satisfactory model of the drying of a square capillary tube.
14

Conception, réalisation et mise en oeuvre d'un microsystème pour la micro spectroscopie par résonance magnétique nucléaire / Design, development and experimental evaluation of an analysis micro system for NMR

Pasquet, Guillaume 10 July 2009 (has links)
Ce travail de thèse porte sur la conception, la réalisation et l’évaluation expérimentale d’ un microsystème d’analyse dont l’originalité repose sur l’intégration d’une micro antenne planaire de spectroscopie par résonance magnétique nucléaire (SRMN) sur un système micro fluidique à base d’un polymère, le Cyclique Oléfine Copolymère (COC). La détermination des caractéristiques géométriques optimales du microsystème afin d’optimiser le couplage électromagnétique entre la micro antenne de détection et l’échantillon est effectuée à l’aide d’un modèle de calcul numérique, ce qui permet l’optimisation du rapport signal sur bruit (RSB). La réalisation du microsystème avec des procédés de micro fabrication développés au laboratoire ont permis de valides son fonctionnement dans un spectromètre dont le champ magnétique statique atteint 11.74 Tesla (fréquence de Larmor du proton égale à 500MHz). Travailler dans un champ aussi intense permet d’améliorer la sensibilité de détection mais nécessite de porter une attention particulière à l’homogénéité du champ magnétique qui, dans notre cas, peut être dégradée en raison de l’introduction du microsystème dans le spectromètre. En effet, les distorsions du champ magnétique, dues aux différentes susceptibilités magnétiques des matériaux constituant la microsonde, ont un impact direct sur la résolution spectrale. C’est pourquoi, une modélisation 3D par éléments finis est proposée afin de prévoir l’influence du microsystème sur la forme des raies spectrales et donc d’en déduire la résolution spectrale pouvant être espérée. La comparaison des résultats expérimentaux et ceux issus des simulations permet de valider le modèle de calcul numérique. Il apparait cependant nécessaire d’inclure le phénomène d’amortissement radiatif afin de pouvoir rendre compte des résultats expérimentaux relatifs à la résolution spectrale effectivement observée. / The work presented in this thesis involves the design, the development and the experimental evaluation of an analysis micro system. The originality of the work lies in the integration of a planar micro coil of spectroscopy by nuclear magnetic resonance (SNMR) on a micro fluidic system based on a polymer, cyclo olefin copolymer (COC). The determination of the optimum geometric characteristics of the micro system to improve electromagnetic coupling between the detection micro coil and the sample is performed with the aid of a numerical model that ensures the optimization of the signal to noise ratio (SNR). Using micro fabrication techniques developed in the laboratory, the micro system was developed and its behaviour was validated in spectrometer producing a static magnetic field off 11.74 Tesla (Larmor frequency of the proton equal to 500MHz). Working in such an intense field results in improved sensitivity of detection but requires paying close attention to the homogeneity of magnetic field. In this case the homogeneity can be degraded due to the introduction of the micro system in the spectrometer. Indeed, the distortions of the magnetic field, due to the different magnetic susceptibilities of the materials constituting the microprobe, have a direct impact on the spectral resolution. As such, 3D modelling by finite elements is proposed to predict the influence of the micro system on the shape of the spectral lines and to determine the best expected spectral resolution. The comparison of the experimental results to those obtained from simulation allows the validation of the numerical model. However, it appears necessary to include the effect of the radiation damping in the model to be able to justify the experimental results relative to the spectral resolution that was observed.
15

Contribution aux développements des technologies de compression polymères chargés pour la réalisation d'inserts métalliques micro-structurés / Hybridation of micro replication processes by hot embossing and roll to roll with loaded polymer for the realization of metallic micro-structured die cavity

Zhang, Jie 18 December 2013 (has links)
Les travaux menés dans le cadre de cette thèse sont focalisés sur les procédés deréplication permettant la transformation des mélanges en composants par les technologiesen séquentiel ou bien en continu, selon les applications visées. Les développementsconcernent la mise en place et l’hybridation de différents procédés de micro-réplication(estampage à chaud de polymère thermoplastique et par laminage circulaire entre deuxrouleaux). Ces deux procédés sont développés et optimisés pour l’élaboration decomposants micro-structurés ou de microcomposants possédant des propriétésfonctionnelles mécaniques ou thermo-physiques requises à partir de différents mélangeschargés en poudres métalliques ou en nanotubes de carbone. Des exemples de réalisationde composants structurés, à base d’un système micro-fluidique possédant plusieurs canauxde 200 microns par 200 microns et des réservoirs de diamètre de 2 mm, sont prises commeexemple tout au long de ces travaux de cette thèse. Différents travaux de caractérisationsont été entrepris pour optimiser les procédés de micro-réplication par estampage à chaud etpar laminage circulaire entre deux rouleaux. / The Ph.D subject concerns the study of two micro-replication processes by hotembossing and roll to roll processes for thermoplastic polymers and loaded polymers withpowders or carbon nanotubes. The micro-replication processes, realized in sequential orcontinuous ways, use some different elaborated loaded feedstocks in order to obtainstructural components or micro-component with high aspect ratio and mechanical orthermo-physical properties.A chain combining hot embossing and roll embossing and powder metallurgy have beendeveloped in our lab and investigated. The different micro mould die cavities have beenrealized with different micro-manufacturing process, elastomeric mould has been obtainedby casting process. Finally, a metallic structured die cavity has been obtained by combininghot embossing and debinding and sintering stages. The second topic is the comparison ofmetallic die cavity mould obtained by roll embossing or rolls embossing. Two demonstratorshave been developed during the preparation of this Ph.D period: first a metallic micro-fluidicsystem with micro-structuration with diameter of 1 mm for the reservoir and 200 microns by200 microns for the channel have been realized and characterized by different methods.Secondly, some functional micro-component has been obtained with carbon nanotube andsome specific properties in terms of mechanic and thermo-physical properties have beencharacterized.

Page generated in 0.0538 seconds