Spelling suggestions: "subject:"microscopia eletrônica dde varredura."" "subject:"microscopia eletrônica dde barredura.""
401 |
Efeito da atmosfera de sinterização na resistência de união da porcelana com ligas de níquel-cromo e cobalto-cromo / Effect of firing atmosphere on metal ceramic bond strength of nickel-chromium and cobalt-chromiumLuciana Mara Negrão Alves 11 February 2015 (has links)
O objetivo deste trabalho foi avaliar a influência de dois diferentes ambientes de sinterização (vácuo e argônio) sobre a resistência da união metaloceramica (RUMC) envolvendo diferentes ligas de metais básicos (Co-Cr e Ni-Cr) e uma porcelana odontológica, através do teste de flexão de três pontos, conforme preconizado pela ISO 9693:2012. As ligas estudadas foram Co-Cr: Remanium e Keragen e Ni-Cr: Verabond II e uma liga experimental “SR” . Foram obtidos 80 corpos de prova em forma tiras metálicas medindo 25 X 0,5 X 5 mm. Para esse ensaio, portanto, o número de corpos de prova foi o produto de 4 ligas x 2 condições de atmosfera de sinterização x 10 repetições. A parte metálica de todos os corpos de prova após a fundição foram usinados e jateados com óxido de alumínio (150μm) e a seguir tratados como preconizado pelo fabricante. O corpo cerâmico, com o auxílio de uma matriz, foi confeccionado na área central da tira, 8,0 X 3,0mm, apresentando 1,1mm de espessura, sendo 10 corpos de prova em cada ambiente de sinterização para cada tipo de liga. Os corpos de prova obtidos foram submetidos aos testes de flexão de três pontos na Máquina de Ensaios Mecânicos (EMIC) com velocidade de 1.0mm/min. para determinação da RUMC. Os valores da carga de ruptura obtidos em quilograma-força (Kgf) foram convertidos para Newton (N) e a partir disso foi calculado o valor da RUMC para cada corpo de prova, considerando o coeficiente de elasticidade de cada liga e a espessura exata de cada corpo de prova. Os dados obtidos (MPa) foram submetidos à análise estatística (ANOVA) e Bonferroni. A Análise de Variância indicou diferença estatisticamente significante para os fatores de variação ambiente (P=0,00), liga (P=0,009) e entre as interações ambiente de sinterização e liga (P=0,000). Na sinterização a vácuo as ligas Keragen, SR e Verabond II apresentaram maiores valores de RUMC do que o argônio. Para a liga Remanium, não houve diferença entre a sinterização em argônio e a sinterização a vácuo. Dentre os grupos sinterizados no argônio não houve diferença estatisticamente significante entre as ligas. Entretanto, no vácuo a liga Remanium apresentou menor valor de RUMC do que as demais ligas, que não apresentaram diferença entre si. Os corpos de prova, após os ensaios de flexão, foram submetidos a análise em microscopia optica, MEV e EDS para avaliar e registrar tipo de falha que sofreram. De acordo com a MO, houve predomínio de fraturas mistas. Os corpos de prova de Co-Cr (Remanium e Keragen), independende do ambiente de sinterização, apresentaram uma fina camada de óxido no corpo cerâmico, o que foi comprovado pelo EDS, com maior presença de íons Cr nessas regiões, já os grupos SR e Verabond II, apresentaram maior quantidade de opaco aderido em suas tiras metálicas. A MEV comprovou os achados da MO, onde foi possível encontrar grandes ilhas de material cerâmico nas ligas de Ni-Cr. A sinterização em argônio influenciou negativamente a RUMC dos pares metalocerâmicos confeccionados em Ni-Cr e na liga Keragem / The aim of this study was to evaluate the influence of two different firing atmosphere (vacuum and argon) on the metalceramic bond strength (MCBS) involving different base metal alloys (Co-Cr and Ni-Cr) and a dental porcelain through three-point bending test, as recommended by ISO 9693: 2012. Co-Cr alloys studied were: Remanium and Keragen and Ni-Cr: Verabond II and an experimental alloy \"SR\". 80 specimens were obtained in metallic form strips measuring 25X0.5 X 5.0 mm. For this test, therefore, the number of specimens was the product of 4 x 2 alloy sintering atmosphere conditions x 10 replicates. The metal portion of all specimens were machined after casting and sandblasted with aluminum oxide (100μm) and then treated as recommended by the manufacturer. By using a matrix, the ceramic body was made in the central area of the strip, 8.0 x 3.0 mm, it was made 1.1 mm thickness, 10 specimens in each sintering environment for each type of alloy. The specimens obtained were tested for three-point bending in a universal testing machine with a speed of 1.0mm / min. to determine MCBS. The values of the tensile strength obtained in kilogramforce (kgf) were converted into Newton (N) and from this the value of MCBS for each specimen was calculated, considering the coefficient of elasticity of each league and the exact thickness of each specimen. The data (MPa) were subjected to statistical analysis (ANOVA) and Bonferroni. The analysis of variance indicated statistically significant difference for the environment factors of firing atmosphere (P = 0.00) and alloy (P = 0.009). There was a statistically significant difference in the interaction factors for firing atmosphere x alloy (P = 0.000). In the vacuum Keragen, SR and Verabond II alloys showed higher MCBS than argon. To Remanium, there was no difference between the sintering in argon and vacuum. Among the groups sintered in argon there was no statistically significant difference between the alloys. However, the vacuum Remanium showed the lowest RUMC than other alloys, which showed no difference between them. The specimens after the bending tests, were subjected to analysis in optical microscopy, SEM and EDS to assess and record type of failure they suffered. According to the MO was predominantly mixed fractures. Specimens of Co-Cr (Remanium and Keragen) independende the atmosphere firing, showed a thin oxide layer on the ceramic body, which was confirmed by EDS, with greater presence of Cr in these regions, since the SR groups and Verabond II, presented more opaque stuck in their metal strips. SEM confirmed the findings of MO, where it was possible to find large islands of ceramic material in Ni-Cr alloys. The sintering in argon negatively influenced MCBS metalceramic of pairs made of Ni-Cr alloy and Keragem
|
402 |
Perfilometria e microscopia eletrônica de varredura da superfície dentinária após escovação com cremes dentais dessensibilizantes e desafio erosivo com fruta amazônica / Profilometry and scanning electron microscopy of dentin surface after brushing with desensitizing toothpastes and challengeMax Pinto da Costa da Rocha 13 December 2012 (has links)
O objetivo deste estudo in vitro foi avaliar o potencial erosivo de suco de fruta amazônica ácida sobre a superfície dentinaria associado ao efeito abrasivo de diversos cremes dentais contendo agentes dessensibilizantes. O trabalho foi dividido em 3 fases distintas: Na fase 1, o valor do pH inicial de diversas frutas amazônicas foi medido utilizando 50 ml de cada suco, obtido de polpa industrializada. Foi utilizado um eletrodo de pH calibrado e a água destilada foi utilizada como controle. Na fase 2, 120 espécimes de dentina bovina foram submetidos a ciclos alternados de desafio abrasivo e erosivo, com a fruta escolhida na fase 1. Os espécimes foram divididos aleatoriamente em Grupo A (Desafio Abrasivo) e Grupo B (Desafio Erosivo e Abrasivo). Cada um destes grupos foram subdivididos em 5 subgrupos: 1: Água Destilada (Controle Negativo), 2: Colgate Tripla Ação (Controle Positivo), e os demais de acordo com o creme dental utilizado 3: Sensodyne Rápido Alívio, 4: Colgate Pró-Alivio e 5: Sensodyne Repair&Protect, (n=9). Na fase 3 foi realizado microscopia eletrônica de varredura para avaliar qualitativamente os espécimes (n=3). - O suco da fruta taperebá (Spondias mombin) apresentou os menores valores de pH, diante disso, foi escolhido como agente erosivo; Os testes de Kruskall Wallis e Teste de Dunn, mostraram que para os grupos nos quais somente a abrasão foi realizada, todos os cremes dentais mostraram comportamentos semelhantes em relação a perfilometria, não havendo diferença estatisticamente significante entre os grupos. Porém, para os grupos nos quais o processo erosivo foi adicionado, observou-se a potencialização do processo abrasivo, sendo que os cremes dentais Sensodyne Rápido Alivio e Colgate Sensitive Pro-Alivio foram os que mostraram menores alterações superficiais no padrão de perfilometria, comparados com o grupo controle negativo. Já os cremes dentais, Colgate Tripla Ação (controle positivo) e Sensodyne Repair&Protect apresentaram-se semelhantes entre si e com uma perda de estrutura dentinaria. mais significante. Conclui-se que o efeito erosivo da fruta amazônica taperebá é fator de grande importância na potencialização do efeito abrasivo, mesmo quando do uso de cremes dentais com agentes dessensibilizantes.. Na análise qualitativa da superfície dentinária em MEV, com exceção do Colgate tripla ação, os demais grupos não apresentaram oclusão tubular após o desafio ácido / The aim of this in vitro study was to evaluate the erosive potential of amazonian fruit juice with or without the abrasive challenge with various toothpastes containing desensitizing agents. The work was divided into three phases: in phase 1, the pH of various Amazonian fruits was evaluated. In step 2 it was performed surface perfilometry of the specimens, and in phase 3 it was evaluated qualitatively the dentin surface. In step 1, the initial pH value of several amazonian fruits was measured using 50 mL of each juice, from industrialized pulp. It was used a calibrated pH electrode, and distilled water was used as control. In step 2, 120 bovine dentin specimens were subjected to alternate cycles of abrasive and erosive challenge, with the fruit chosen in step 1. The specimens were randomly divided into Group A (without erosion) and Group B (with erosion). Each of these groups were divided into 5 groups: 1: Distilled Water, 2: Colgate Tripla Ação, 3: Sensodyne Rápido Alívio, 4: Pro-Alivio, 5: Sensodyne Repair & Protect, (n = 9). In Phase 3 it was conducted scanning electron microscopy to evaluate qualitatively the specimens (n=3). As a result it can be stated that: 1. The juice of the taperebá fruit had the lowest pH values, so it was chosen as the erosive agent; 2. For the groups in which only the abrasion was performed, all toothpastes showed similar behaviors, no statistically significant difference was observed between groups, but for the groups in which the erosion process was added, there was a potentiation of the abrasive process, and the toothpastes showed different profiles. The toothpaste Sensodyne Rapido Alívio Pró-Alívio was the ones that showed lower mineral loss, compared with the negative control group. Colgate Tripla Ação and Sensodyne Repair&Protect were similar among themselves and with a more significant mineral loss. It can be conclude that erosive effect of diet is a factor of great importance in the potentiation of abrasive effect. Clinical studies are essential to determine the dentin hypersensitivity levels after use of toothpaste used.
|
403 |
Estudo longitudinal da resistência e qualidade de união de diferentes sistemas adesivos à dentina irradiada com laser de femtossegundos / Long term evaluation of bond strength and quality of the interface of different adhesive systems to femtosecond laser irradiated dentinSimone Gonçalves Moretto 17 December 2012 (has links)
Recentemente, os lasers de pulsos ultracurtos têm sido avaliados para o preparo dos tecidos duros dentais devido à sua habilidade de reduzir os efeitos térmicos resultantes da irradiação. O objetivo deste estudo foi avaliar a efetividade de união de 3 sistemas adesivos à dentina preparada com o laser de femtossegundos (10-15 s). Para isso, 60 terceiros molares foram preparados com o laser de femtossegundos (1.450 nm; 0,3W; 100.000Hz) ou ponta diamantada, divididos em 3 subgrupos (n=10) restaurados utilizando o adesivo condicione e lave de 3 passos Optibond FL (OFL; Kerr), o autocondicionante de 2 passos Clearfil SE (CSE; Kuraray) ou o autocondicionante de 1 passo G-aenial Bond (GAB; GC). Após 1 semana de armazenamento em água, os dentes foram seccionados (1,0x1,0 mm) e testados imediatamente e após 6 meses de armazenamento. Vinte e quatro amostras adicionais foram preparadas com o laser ou ponta diamantanda conforme descrito acima. Seis amostras foram seccionadas em espécimes menores e aleatoriamente preparados para observação das características morfológicas da superfície (n=3) e subsuperfície (n=3) em Microscópio Eletrônico de Varredura (MEV) (n=3) e Microscopia Eletrônica de Transmissão (MET) (n=3). As outras 18 amostras foram restauradas com os sistemas adesivos supramencionados, seccionados em espécimes menores e distribuídos para avaliação da interface adesiva em MEV (n=3) e padrão de nanoinfiltração após 1 semana (n=2) e 6 meses (n=2) em MET. O modelo linear de efeitos mistos (=0,05) revelou um efeito significante dos fatores adesivo, armazenagem e a interação preparo x armazenagem na resistência de união. Todos os adesivos apresentaram uma redução significante da resistência de união após 6 meses de armazenamento (p<0,0001) para ambos os tipos de preparo. Com relação ao sistema adesivo, a única diferença verificada foi o maior valor de resistência de união do GAB quando aplicado sobre as superfícies irradiadas (56,71±10,72 MPa) quando comparadas com as preparadas com ponta diamantada (43,14±14,93 MPa) após 1 semana de armazenamento. A análise de fratura revelou fraturas mistas, adesivas e coesivas em dentina para ambos os métodos de preparo com um discreto aumento do número de fraturas mistas após 6 meses de armazenamento exceto para o GAB, que apresentou principalmente fraturas adesivas e mistas. A análise em MEV revelou uma fina camada de debris sobre a superfície da dentina irradiada e a hibridização com todos os sistemas adesivos resultou num íntimo contado da interface adesiva com o substrato. A análise em MET da subsuperfície irradiada revelou fibrilas colágenas preservadas. A análise da interface adesiva revelou um aumento dos depósitos de prata na camada híbrida para todos os adesivos, após 6 meses de armazenamento, independentemente do tipo de preparo. Apenas o GAB apresentou maiores depósitos de prata após 1 semana de armazenamento para as superfícies preparadas com ponta diamantada. A irradiação com o laser de femtossegundos não reduziu a receptividade da dentina aos sistemas adesivos, resultando em valores de resistência de união similares aos obtidos com a ponta diamantada; além de uma ótima interação do substrato com os sistemas adesivos e deposições de prata similares àquelas obtidas com a ponta diamantada. / Recently, the applicability of ultrashort pulsed lasers has been studied for dental hard-tissue irradiation because of its reduced residual thermal damage. The aim of this study was to determine the bonding effectiveness of 3 contemporary adhesive systems to dentin prepared by femtosecond (10-15 sec) laser-irradiation. For this, 60 third molars were prepared either by the femtosecond laser (1450 nm; 0.3W; 100,000Hz) or by bur, randomly divided into 3 subgroups (n=10) and restored with a composite using either the 3-step etch-and-rinse adhesive Optibond FL (OFL; Kerr), the 2-step self-etch adhesive Clearfil SE (CSE; Kuraray) or the 1-step self-etch adhesive G-aenial Bond (GAB; GC). After 1-week water storage, the teeth were sectioned (1.0x1.0 mm) and half of the specimens were tested until failure using a micro-tensile bond-strength (TBS) approach. The other half was stored in water and tested after 6 months. Twenty-four additional dentin samples were exposed to the diamond bur and the laser, following the same abovementioned parameters. Three samples of each treatment were sectioned in smaller specimens in order to be characterized for surface (n=3) and cross-sectional morphological analysis using Scanning Electron Microscopy (SEM) (n=3) and Transmission Electron Microscopy (TEM) (n=3). The other eighteen samples were hybridized with the abovementioned adhesive systems, sectioned in smaller samples and distributed for evaluation of the interface under SEM (n=3) and nanoleakage distribution for 1 week (n=2) and 6 months (n=2) under TEM. Linear mixed effect model (=0.05) revealed a significant effect of the factors adhesive, storage and the interaction of preparation x storage on the TBS. All adhesives presented a significant reduction of the bond strength after 6-month storage (p<0.0001) for both preparation methods. Regarding the adhesive system, the only difference found was a significantly higher TBS of GAB to laser-irradiated (56.71±10.72 MPa) than to bur-cut dentin (43.14±14.93 MPa) after 1-week water storage. Fracture analysis showed mixed, adhesive and cohesive failures in dentin similarly for both preparation methods with a slightly increase of the mixed failures after 6-months water storage for OFL and CSE, but not for GAB that presented mainly adhesive and mixed failures. SEM disclosed a thin layer of debris on the laser-irradiated dentin surface and the hybridization with all adhesive systems resulted in a very tight interface. TEM analysis of the irradiated subsurface revealed collagen fibrils preserved and for the nanoleakage evaluation an increase of silver deposits at hybrid layer for all adhesives testes after 6-months water storage, irrespective of the preparation methods. Only the GAB presented great silver deposits even after 1-week water storage for the bur-cut preparation method. Femtosecond laser irradiation did not reduce the bonding receptiveness of dentin resulting in similar values obtained with the preparation by bur. Additionally it led to a great interaction with different adhesive systems and silver deposits comparable to those obtained with the bur-cut preparation method.
|
404 |
Obtenção e caracterização de supercondutores de Bi2212 texturizados com introdução de centros artificiais de aprisionamento / Production and characterization of textured Bi2212 superconductors with introduction of artificial pinning centers.Eliana Cursino 10 September 2010 (has links)
O presente trabalho analisou as condições de texturização de amostras de Ag/Bi2212 (Bi2Sr2CaCu2O8+δ) na forma de pastilhas e de fitas, verificando-se a influência do tratamento térmico, atmosfera, adição de prata e adição de zircônia ou zirconato de cálcio. As adições de zircônia ou de zirconato de cálcio, com partículas de dimensões submicrométricas ou nanométricas (abaixo de 200nm), foram analisadas como possíveis geradores de centros de aprisionamento de fluxo magnético, assim como foi feita a análise de seus comportamentos nas propriedades intrínsecas da matriz supercondutora. A influência da atmosfera de tratamento térmico foi analisada de modo a alterar a concentração de oxigênio na fase supercondutora visando melhores resultados de temperatura crítica, sem depreciação das densidades de corrente crítica e dos campos de irreversibilidade, Birr. Foram analisadas as influências dos parâmetros de tratamento térmico, tais como temperatura máxima de reação, tempo nesta temperatura máxima, taxa de resfriamento do estado líquido ao estado sólido, e temperatura e tempo de recozimento após solidificação. Verificou-se a influência do resfriamento do forno sobre a texturização e a temperatura crítica. Quanto à dopagem com prata, foi verificada sua influência na texturização e interação com a zircônia. Foram realizadas caracterizações supercondutoras e microestruturais das amostras. / The present work analyzed the texturing conditions of Ag/Bi2212 samples (Bi2Sr2CaCu2O8+δ) in the form of bulks and of tapes, verifying the influence of heat treatment, atmosphere, silver addition and addition of zirconia or calcium zirconate. The additions of zirconia or calcium zirconate, with particles of submicron or nanometric (below 200nm) dimensions, were analyzed as possible generators of magnetic flux pinning centers, as well as it was analyzed their behaviors on the intrinsic properties of the superconducting matrix. The influence of the heat treatment atmosphere was analyzed in order to change the oxygen concentration in the superconducting phase aiming better results of critical temperature, without depreciation of the critical current densities and of the irreversibility fields, Birr. The influences of the heat treatment parameters were analyzed, such as the reaction maximum temperature, soaking time at this maximum temperature, cooling rate from the liquid to the solid states, and annealing temperature and time after solidification. It was verified the influence of the furnace cooling rate on the texturing and critical temperatures. Concerning to the silver addition, it was verified its influence on the texturing and its interaction with the zirconia. Superconducting and microstructural characterizations of the samples were performed.
|
405 |
Efeito da condição do substrato e do tempo de condicionamento na estabilidade da união de sistemas adesivos à dentina de dentes decíduos / Effect of substrate condition and etching time on the bonds stability of adhesive systems to dentin of primary teethTathiane Larissa Lenzi 03 May 2013 (has links)
Este estudo objetivou investigar a influência da redução do tempo de condicionamento na união de sistemas adesivos à dentina hígida e afetada por cárie de dentes decíduos, por meio de testes de microtração, nanoinfiltração e avaliação micromorfológica da interface adesiva. A superfície dentinária de 48 segundos molares decíduos foi exposta e os dentes divididos aleatoriamente em 8 grupos experimentais de acordo com o substrato (dentina hígida e afetada por cárie ciclagem de pH por 14 dias), sistema adesivo (Adper Single Bond 2 adesivo convencional de dois passos e Clearfil SE Bond - sistema autocondicionante de dois passos) e tempo de condicionamento (recomendado pelo fabricante e metade do tempo). Desta forma, o adesivo Adper Single Bond 2 foi aplicado à dentina após condicionamento com ácido fosfórico a 35% por 15 ou 7 segundos e o agente de união do Clearfil SE Bond após 20 ou 10 segundos de aplicação do primer. Blocos de resina composta (Filtek Z250) foram confeccionados e, após 24 horas de armazenamento em água destilada, os dentes foram seccionados para obtenção de espécimes com área de secção transversal de aproximadamente 0,8 mm2. Metade dos espécimes foi submetida imediatamente ao teste de microtração e a outra metade após 12 meses de armazenamento em água destilada. O padrão de fratura foi avaliado em estereomicroscópio com aumento de 400x. Dois espécimes de cada dente nos respectivos períodos de armazenamento foram imersos em nitrato de prata amoniacal por 24 horas e revelados (8 horas) para avaliação da nanoinfiltração em microscopia eletrônica de varredura. Adicionalmente, dois dentes para cada grupo experimental (n=16) foram preparados como descrito para o teste de microtração e seccionados perpendicularmente à interface adesiva, após 24 horas, para análise da micromorfologia e espessura da camada híbrida. Os valores de resistência de união, expressos em megapascal (MPa), foram submetidos à Análise de Variância (ANOVA) e teste de Tukey ( = 0,05). As demais avaliações foram descritivas. Os sistemas adesivos apresentaram valores similares de resistência de união imediata. Decréscimo dos valores de resistência de união ocorreu após 12 meses de armazenamento em água, exceto para o adesivo Clearfil SE Bond em substrato hígido. A adesão à dentina afetada foi menor em comparação à dentina hígida. A nanoinfiltração também foi mais pronunciada neste substrato. O tempo de condicionamento influenciou apenas a adesão do sistema adesivo Adper Single Bond 2. Maiores valores de resistência de união e menor infiltração de nitrato de prata na interface adesiva foram observados quando o tempo de condicionamento ácido foi reduzido pela metade, independente do substrato. Camadas híbridas mais finas foram produzidas quando a dentina decídua foi condicionada por 7 segundos, especialmente em dentina afetada. Predomínio de fratura adesiva/mista foi observado para todos os grupos experimentais. Em conclusão, o efeito da redução no tempo de condicionamento é material dependente e resulta em maior estabilidade da união de sistema adesivo convencional de dois passos à dentina hígida e afetada de dentes decíduos. / This study aimed to investigate the influence of shortening the etching time on bond of adhesive systems to sound and caries-affected dentin of primary teeth by microtensile and nanoleakage tests, and micromorphological evaluation of the adhesive interface. The dentinal surface of 48 second primary molars was exposed and the teeth were randomly assigned to 8 experimental groups according to substrate (sound and caries-affected dentin - pH-cycling for 14 days), adhesive system (Adper Single Bond 2 two-step etch-and-rinse adhesive system and Clearfil SE Bond two step self-etch adhesive system) and etching time (recommend by manufacturers and half-reduced time). Thus, the adhesive Adper Single Bond 2 was applied to dentin after 35% phosphoric acid etching for 15 or 7 seconds, and the bond of Clearfil SE Bond after 20 or 10 seconds of primer application. Composite resin blocks (Filtek Z250) were built and, after 24 hours of storage in distilled water, the teeth were sectioned to obtain specimens with cross-sectional area of approximately 0.8 mm2. Half of the specimens were immediately subjected to microtensile test and the other half after 12 months of storage in distilled water. The fracture pattern was evaluated with a stereomicroscope at 400x magnification. Two specimens from each tooth in the respective storage periods were immersed in ammoniacal silver nitrate for 24 hours and revealed (8 hours) to evaluate the nanoleakage in scanning electron microscope. Additionally, two teeth for each experimental group (n=16) were prepared as described for the microtensile test and perpendicularly sectioned to the adhesive interface, after 24 hours, for analysis of micromorphology and thickness of the hybrid layer. Bond strength values, expressed in megapascal (MPa), were submitted to Analysis of Variance (ANOVA) and Tukeys tests ( = 0.05). Other evaluations were descriptive. The adhesive systems presented similar immediate bond strength values. A decrease in bond strength values occurred after 12 months of water storage, except for Clearfil SE Bond in sound substrate. Bonding to caries-affected dentin was lower compared to sound dentin. The nanoleakage was also more pronounced in this substrate. Etching time only influenced the bonding of the adhesive system Adper Single Bond 2. Higher bond strength values and lower infiltration of silver nitrate into adhesive interface were observed when the etching time was half-reduced, irrespective of the substrate. Thinner hybrid layers were produced when the primary dentin was acid etched for 7 seconds, especially in caries-affected dentin. Predominance of adhesive/mixed fracture was observed for all experimental groups. In conclusion, the effect of shortening the etching time is material dependent and results in higher bond stability of two-step etch-and-rinse adhesive system to sound and caries-affected dentin of primary teeth.
|
406 |
Aspectos ultraestruturais da acroqueratoelastoidoseLOPES, Jivago da Fonseca 05 December 2017 (has links)
Submitted by Cristiane Chim (cristiane.chim@ucpel.edu.br) on 2018-06-04T13:08:21Z
No. of bitstreams: 1
JIVAGO DA FONSECA LOPES.pdf: 9499582 bytes, checksum: 9c8c5dfe7ba36c11cfe8d157cbaf26b7 (MD5) / Made available in DSpace on 2018-06-04T13:08:21Z (GMT). No. of bitstreams: 1
JIVAGO DA FONSECA LOPES.pdf: 9499582 bytes, checksum: 9c8c5dfe7ba36c11cfe8d157cbaf26b7 (MD5)
Previous issue date: 2017-12-05 / Acrokeratoelastoidosis (AQE) is a type of keratoderma that affects the region palmoplantar, originally described by the dermatologist miner Oswaldo Gonçalves Costa in 1953. It is a rare, autosomal dominant disease, but can occur sporadic. The disease has the first manifestations in childhood and adolescence, but it can occur in adults in a late presentation. The clinical picture is characterized by multiple yellowish, sometimes translucent and keratotic papules, measuring approximately 2-4 mm in diameter, occasionally umbilicated, located at the margin side of the hands and feet, symmetrically, what is its most typical clinical expression. The findings Histopathological findings are: hyperkeratosis, mild acanthosis and elastorrexis. Diagnosis is clinical, corroborated by optical microscopy with specific staining for elastic fibers, which shows a decrease in them. In addition, the electron microscopy (ME) is an important ally to elucidate of AKE. Due to the limited findings in the literature using this technique - scarce studies with analysis of transmission electron microscopy (MET) and none using scanning electron microscopy (MEV) - this study will describe a case of AQE, analyzing its clinical and ultrastructural aspects, two-dimensional with MET and with the MEV, after adequate preparation of the sample using a specific technique to analysis of biological material. It is hoped, therefore, to better describe the disease and contribute for further research in the area, in an attempt to better understand the etiopathogenesis and, to seek more effective forms of treatment than time. / Acroqueratoelastoidose (AQE) é um tipo de queratodermia que acomete região
palmoplantar, originalmente descrita pelo dermatologista mineiro Oswaldo Gonçalves Costa
em 1953. É uma doença rara, de carater autossômico dominante, porém pode ocorrer de forma
esporádica. A doença tem as primeiras manifestações na infância e adolescência, mas pode
ocorrer em adultos, em uma apresentação tardia. O quadro clínico é caracterizado por
múltiplas pápulas amareladas, por vezes translúcidas e queratóticas, medindo
aproximadamente 2-4 mm de diâmetro, ocasionalmente umbilicadas, localizadas na margem
lateral das mãos e pés, simetricamente, o que é sua expressão clínica mais típica. Os achados
histopatológicos mais comuns são: hiperqueratose, acantose discreta e elastorrexe.O
diagnóstico é clinico, corroborado pela microscopia óptica com coloração específica para
fibras elásticas, a qual mostra diminuição das mesmas. De forma complementar, a
microscopia eletrônica (ME) mostra-se como importante aliada para elucidar aspectos
ultraestruturais da da AQE. Devido aos achados limitados na literatura utilizando esta técnica
– estudos escassos com análise de microscopia eletrônica de transmissão (MET) e nenhum
utilizando microscopia eletrônica de varredura (MEV) - esse estudo irá descrever um caso de
AQE, analisando seus aspectos clínicos e ultraestruturais, bidimensionais com a MET e
tridimensionais com a MEV, após preparo adequado da amostra com técnica específica para
análise de material biológico. Espera-se, com isso, descrever melhor a doença e contribuir
para mais pesquisas na área, na tentativa de compreender melhor a etiopatogenia e,
consequentemente, buscar formas de tratamento mais eficazes que as existentes até o
momento.
|
407 |
Intercambialidade de componentes protéticos em diferentes marcas de implantes / Evaluation of the connecting accuracy of interchanged prosthetic abutments to different dental implants using scanning electron microscopyZanardi, Piero Rocha 05 November 2012 (has links)
O presente estudo avaliou a intercambiabilidade dos componentes protéticos de implantes de hexágono externo medindo-se a precisão da interface implante/pilar (I/P) com microscopia eletrônica de varredura. Foram utilizados dez implantes para cada uma de três marcas (SIN, Conexão, Neodent) com seus respectivos pilares (base metálica de CoCr , rotacional e não rotacional) e um de marca alternativa (Microplant) em um arranjo com todas as combinações de I/P possíveis. O valor de referência para a intercambiabilidade das várias marcas de componentes foi definido pela diferença do pilar original para com seu respectivo implante. Dessa maneira, a intercambiabilidade foi considerada válida quando o resultado para um determinado pilar colocado sobre um implante fosse igual ou menor que a diferença medida, quando o pilar da mesma marca do implante foi posicionado. Um grau de desajuste foi observado em todos os espécimes. De uma maneira geral, o pilar antirrotacional foi mais preciso do que o rotacional. Estes variaram de 0,6 16,9m, com mediana 4,6m, enquanto o antirrotacional foi de 0,3 12,9m, com mediana de 3,4m. Os espécimes com o pilar e o implante Conexão tiveram uma diferença maior que o conjunto original para SIN e NEO (p<0,05). Apesar de estes últimos apresentarem resultados semelhantes com seus respectivos pilares, quando trocados, não mantiveram a mesma precisão original. Os resultados sugerem que a marca alternativa seria a única que apresentaria compatibilidade com todos os sistemas, enquanto as outras marcas não seriam completamente intercambiáveis. / The present study evaluated the interchangeability of prosthetic components for external hexagon implants by measuring the precision of the implant/abutment (I/A) interface using scanning electron microscopy. Ten implants for each of three brands (SIN, Conexão, Neodent) were tested with their respective abutments (milled CoCr collar rotational and non-rotational) and that of an alternative manufacturer (Microplant) in randomly arranged I/A combinations. The degree of interchangeability between the various brands of components was defined using the original abutment interface gap with its respective implant as the benchmark dimension. Accordingly, when the result for a given component placed on an implant was equal to or smaller then that gap measured when the component of the same brand as the implant was positioned, interchangeability was considered valid. Some degree of maladjustment was observed on all specimens. Generally, the non-rotational component was more accurate than its rotational counterpart. The latter samples ranged from 0.6 16.9m, with a median of 4.6m; the former from 0.3 12.9m, with a median of 3.4m. Specimens with the abutment and fixture from Conexão had larger microgap than the original set for Sin and Neodent (p<0.05). Even though the latter systems had similar results with their respective components, their interchanged abutments did not reproduce the original accuracy. The results suggest that the alternative brand abutment would have compatibility with all systems while the other brands were not completely interchangeable.
|
408 |
Efeito da radioterapia sobre as propriedades mecânicas, químicas e morfológicas do esmalte e da dentina de dentes permanentes - Estudo in vitro / Effect of radiotherapy on the mechanical, chemical and morphological property of the enamel and of the dentine of permanent teeth - In vitro studyGonçalves, Ligia Maria Napolitano 14 March 2012 (has links)
O presente estudo teve como objetivo avaliar, in vitro, os efeitos da radiação com cobalto-60 nas propriedades mecânicas, morfológicas e químicas do esmalte e da dentina de dentes permanentes através da: 1- microdureza longitudinal; 2- microscopia eletrônica de varredura (MEV); e 3- espectroscopia de energia dispersiva de raios X (EDX). A microdureza do esmalte e da dentina (n=12 hemissecções vestibulares) foi avaliada em três profundidades (superficial, média e profunda), antes e a cada 10 Gy de irradiação, até uma dose cumulativa de 60 Gy. A morfologia do esmalte e da dentina foi avaliada por meio de MEV (n=8 hemissecções), em 2 hemissecções vestibulares irradiadas com dose cumulativa de 30 Gy, 2 hemissecções vestibulares irradiadas com dose cumulativa de 60 Gy e 4 hemissecções palatinas não irradiadas. A composição química do esmalte e da dentina foi avaliada por meio de EDX (n=4 hemissecções), utilizando-se as mesmas hemissecções previamente submetidas à MEV (com dose cumulativa de 60 Gy de irradiação, e nas hemissecções não irradiadas). Os dados foram analisados quanto à sua distribuição e submetidos à Análise de Variância a dois critérios. Para a diferenciação das médias, empregou-se o teste de Fisher. O nível de significância adotado foi de 5%. Com relação à microdureza no esmalte, pôde-se observar que houve diferença estatisticamente significante entre os grupos (p < 0,05). A microdureza no esmalte não irradiado não apresentou diferença estatisticamente significante em comparação com a do esmalte após irradiação com doses de 40, 50 e 60 Gy (p > 0,05), e apresentou-se maior que os valores de microdureza nas doses de 10, 20 e 30 Gy (p < 0,05). Com relação à microdureza nas diferentes profundidades pôde-se observar diferença significante (p < 0,05) entre elas, observando-se no esmalte superficial seus maiores valores. Na análise morfológica do esmalte observou-se que os espécimes irradiados apresentaram alterações crescentes, em função do aumento da dose de radiação, em comparação ao esmalte não irradiado. A porção interprismática tornou-se mais evidente após as doses de 30 e 60 Gy. Em relação à microdureza da dentina, pôde-se observar que houve diferença significante entre os grupos (p < 0,05). A microdureza na dentina não irradiada não apresentou diferença estatisticamente significante em comparação com a microdureza na dose de 40 Gy (p > 0,05) e apresentou valores superiores aos observados nas doses de 10, 20, 30, 50 e 60 Gy (p < 0,05). Em relação à microdureza nas diferentes profundidades avaliadas pôde-se observar diferença significante (p < 0,05) entre elas, sendo que a dentina média apresentou seus maiores valores. Na análise morfológica da dentina observou-se a presença de fendas na estrutura dentinária, túbulos dentinários colabados/destruídos e fragmentação das fibras colágenas nas doses de 30 e 60 Gy, sendo as alterações mais intensas com aumento da dose de irradiação, para todas as regiões analisadas, em comparação à dentina não irradiada. Na análise química do esmalte e da dentina irradiados observou-se discreto aumento de oxigênio (O) e diminuição de fósforo (P) e cálcio (Ca), em comparação aos espécimes não irradiados. Os resultados permitiram concluir que a radioterapia não influenciou a microdureza do esmalte, como um todo, entretanto, quando analisou-se nas diferentes profundidades do esmalte, verificou-se um aumento da microdureza na região superficial. Na dentina, a radioterapia ocasionou diminuição da microdureza após praticamente todas as doses de radiação, em comparação à dentina não irradiada, sendo que na região da dentina média observaram-se seus menores dos valores. As alterações morfológicas das estruturas do esmalte e da dentina foram crescentes com o aumento das doses de irradiação observando-se a porção interprismática mais evidente, presença de fendas e túbulos dentinários colabados/destruídos e fragmentação progressiva das fibras colágenas. Quimicamente, após a irradiação, tanto no esmalte como na dentina, observouse um discreto aumento na porcentagem de oxigênio e redução nas porcentagens de fósforo e cálcio. / The present study had as objective to evaluate, in vitro, the effect of the radiation of 60 Cobalt (Co 60) in the mechanical, morphological and chemical properties of the enamel and of the dentine of permanent teeth by means of: 1- longitudinal microhardness; 2- scanning electron microscopy (SEM); and 3; energy dispersive X-ray spectroscopy (EDX). The microhardness of the enamel and of the dentine (n = 12 vestibular hemisections) was evaluated in three depths (superficial, medium and deep), before and at each 10 Gy of irradiation, until a total cumulative dose of 60 Gy. The morphology of the enamel and of the dentine was evaluated by means of a SEM (n = 8 hemisections), in 2 irradiated vestibular hemisections with total cumulative dose of 30 Gy, 2 irradiated vestibular hemisections with total cumulative dose of 60 Gy and 4 not irradiated palatine hemisections (control). The chemical composition of the enamel and of the dentine was evaluated by means of EDX (n = 4 hemisections), using the same hemisections previously submitted to SEM (with cumulative dose of 60 Gy of irradiation, and in the not irradiated hemisections). The data were analyzed about their distribution and submitted to the Analysis of Variance at two criteria. For the differentiation of the averages, the test of Fisher was used. The level of significance adopted was of 5%. About the longitudinal microhardness in the enamel, it was possible to be observed that there was no statistically significant difference between the groups (p < 0,05). The microhardness in the not irradiated enamel was similar to the enamel after the irradiation with doses of 40, 50 and 60 Gy (p > 0,05) and higher than the microhardness values in the doses of 10, 20, e 30 Gy (p < 0,05). About the microhardness in the different depths it was observed significant difference (p < 0,05) between them, being observed in the superficial enamel the greatest values of microhardness. In the morphological analysis of the enamel it was observed that the irradiated specimens presented growing alterations, due to the increase of the radiation dose, comparing to the not irradiated enamel. There was no difficulty in observing the prisms and the crystals after the irradiation, however the interprismatic portion became more evident after the radiation doses of 30 and 60 Gy. About the longitudinal microhardness of the dentine, it could be observed that there was significant difference between the groups (p < 0,05). The microhardness of the not irradiated dentine was not statistically significant compared to the microhardness in the dose of 40 Gy (p > 0,05) and it presented higher values to the observed ones in the doses of 10, 20, 30, 50 and 60 Gy (p < 0,05). About the relation to the microhardness in the different evaluated depths it was possible to observe significant difference (p < 0,05) among them, being that the medium dentine presented the highest values of microhardness. In the morphological analysis of the dentine it was observed the presence of cracks in the dentine structure, collapsed/destroyed dentine tubules and fragmentation of the collagen fibers in the doses of 30 and 60 Gy, being the alterations more intense with the increase of the dose of irradiation, for all the analyzed regions, comparing to the not irradiated dentine. In the chemical analysis of the irradiated enamel and the dentine it was observed the slight increase of oxygen (O) and decrease of phosphorus (P) and Calcium (Ca), comparing to the not irradiated specimens. The result allowed to be concluded that the radiotherapy occasioned the decrease of the microhardness of the enamel after the doses from 10 to 30 Gy, but in the following doses there was an increase of the microhardness, which became similar to the not irradiated enamel, being that in the superficial region it was observed the biggest increase of the microhardness. In the dentin, the radiotherapy caused decrease of the microhardness after practically all doses of radiation, comparing to the not irradiated dentine, being that in the region of the medium dentine the lowest values of microhardness were observed. The morphological alterations of the enamel and of the dentine structure were growing with the increase of the radiation doses observing the more evident interprismatic portion, presence of cracks and collapsed/destroyed dentine tubules and progressive fragmentation of collagen fibers. Chemically, after the irradiation, not only in the enamel but also in the dentin, it was observed a slight increase of percentage of the oxygen and decrease in the percentages of phosphorus and calcium.
|
409 |
Efeitos biológicos do tratamento de condicionamento radicular em dentes afetados periodontalmente - análise in vitroSilva, Aline Cristina 28 February 2013 (has links)
The objective of this study was to evaluate the root surfaces modifications after the application of different chemicals agents, and their influence on the attachment of a fibrin network and fibroblasts. From 96 anterior mandibular human incisor teeth, extracted due to severe periodontal disease, were obtained 192 dentin blocks (3x3x1 mm) of buccal and lingual surface and randomly divided into 6 groups: Control- control group, which received no treatment; Root surface scaling and root planing (SRP) - root surface was scaling and root planning with Gracey curetes; Citric acid - SRP + 30% citric acid 5 min; EDTA (ethylenediaminetetraacetic acid) - SRP + 24% EDTA gel for 1 min; Tetracycline capsule - SRP + for 3 min with a solution obtained by dissolving one 500 mg capsule of tetracycline in 2 mL of saline solution; Tetracycline gel - SRP + 50 g/mL tetracycline gel for 1 min. After dentin treatment the specimens were analyzed using 4 methodologies: 1- the demineralization level and residues of the product (n = 9); 2- the adhesion of blood components after 20 min of surface treatment (n = 9); 3- the fibroblast attachment after 24h (n = 9), were analyzed by scanning electron microscopy (SEM); and 4- the cell metabolism after 4h (n = 5) the methyltetrazolium (MTT) assay was used. Citric acid, EDTA and Tetracycline gel removed completely smear layer and smear plug on root surface, resulted in adequate demineralization .Tetracycline capsule produced great tetracycline residues with several demineralization areas on root dentin surface. Tetracycline gel and EDTA groups had more fibroblast fixation than other experimental groups. The highest mean blood clot adhesion score was observed in roots treated with a tetracycline gel, whereas, the least score was observed in roots treated with tetracycline capsule. These results demonstrated that EDTA and Tetracycline gel surface demineralization removed the smear layer over dentin surface and promoted adhesion of a fibrin network and fibroblast cells attachment. The Tetracycline capsule demonstrated less effective performance in all parameters tested. / O objetivo deste estudo foi avaliar as modificações nas superfícies radiculares após a aplicação de diferentes agentes químicos, e sua influência na inserção de rede de fibrina e fibroblastos. De 96 dentes incisivos anteriores humanos, extraídos devido doença periodontal severa, foram obtidos 192 blocos de dentina (3x3x1 mm) da superfície vestibular e lingual e aleatoriamente divididos em seis grupos: controle, que não receberam tratamento, raspagem e alisamento radicular (RAR) - superfície radicular foi raspada e alisada com curetas Gracey, Ácido cítrico - RAR + ácido cítrico 30% por 5 min; EDTA (ácido etilenodiaminotetracético) - RAR + gel de EDTA 24% por 1 min; Tetraciclina cápsula RAR + solução obtida por dissolução de uma cápsula de 500 mg de tetraciclina em 2 ml de solução salina por 3 minutos; Tetraciclina gel - RAR + 50 mg / mL de tetraciclina gel por 1 min. Após o tratamento, as amostras de dentina foram analisadas utilizando 4 metodologias diferentes: 1- o nível de desmineralização e de resíduos do produto (n = 9); 2- a adesão das componentes do sangue no tratamento de superfície após 20 min (n = 9); 3- a inserção de fibroblasto após 24 horas (n = 9), que foram analisadas por microscopia eletrônica de varredura (MEV), e 4- o metabolismo celular após 4h (n = 5), o ensaio com metiltetrazólio (MTT) foi utilizado. Ácido cítrico, EDTA e tetraciclina gel removeram completamente, smear layer e smear plug na superfície radicular, resultando em adequada desmineralização. Tetraciclina cápsula produziu grande resíduos de tetraciclina com áreas severas de desmineralização na superfície de dentina radicular. Grupos Tetraciclina gel e EDTA tiveram maior inserção de fibroblastos que os outros grupos experimentais. A maior média de adesão do coágulo sanguíneo pontuada foi observada em raízes tratadas com a tetraciclina gel, enquanto que, a menor pontuação foi observada em raízes tratadas com tetraciclina cápsula. Estes resultados demonstram que a desmineralização da superfície pelo EDTA e pela tetraciclina gel removeram a smear layer que cobria a superfície da dentina e promoveram adesão da rede de fibrina e inserção de células dos fibroblastos. A Tetraciclina cápsula demonstrou desempenho menos efetivo em todos os parâmetros testados. / Mestre em Odontologia
|
410 |
Efeito do ambiente de sinterização na resistência de união de cerâmicas a ligas de níquel-cromo, cobalto-cromo e titânio comercialmente puro / Effect of firing atmosphere on metal ceramic bond strength of nickelchromium, cobalt-chromium and commercially pure titaniumMilena Teixeira da Rocha 23 November 2012 (has links)
O objetivo deste trabalho foi avaliar o efeito do ambiente de sinterização vácuo e argônio na resistência de união (RUMC) de cerâmicas às ligas de Ni-Cr (Fit Cast SB), Co-Cr (Star Loy C) e titânio comercialmente puro (Tritan). A partir de uma matriz de teflon, foram obtidos 60 padrões de resina/cera em forma de cilindro, com 8 mm de comprimento e 5 mm de diâmetro. Os padrões foram incluídos e os anéis foram levados ao forno e submetidos a ciclos térmicos para a expansão do revestimento. Em seguida, os anéis para fundição em Ni-Cr e Co-Cr foram levados à máquina de fundição por indução eletrônica. Os anéis referentes ao titânio foram levados à máquina de fundição por arco voltaico. Após resfriamento dos anéis, as fundições foram desincluídas e jateadas com óxido de alumínio (100 μm). Depois de recortados dos canais de alimentação, os cilindros metálicos foram preparados para aplicação da cerâmica. Em seguida, foi realizada a aplicação e sinterização da cerâmica à vácuo ou em argônio. Para as ligas alternativas, foi utilizada a cerâmica IPS Classic V e para o titânio, a Triceram. Na sequência, os cilindros compostos pelo metal e disco cerâmico (5 mm de diâmetro e 2 mm de espessura) (n=10) foram submetidos aos ensaios de RUMC por cisalhamento na máquina de ensaios universais com célula de carga de 500 Kg e velocidade do travessão móvel de 0,5 mm/min. Após os ensaios, foram realizadas análises das fraturas por meio de microscopia óptica (MO) (15X) e microscopia eletrônica de varredura (MEV). Os dados de RUMC (MPa) obtidos foram analisados estatisticamente pelos testes ANOVA e Tukey (α=0,05). Os resultados demonstraram que a sinterização à vácuo propiciou obtenção de maiores valores (MPa) de RUMC (76,58) que a sinterização em argônio (51,31). Quanto às ligas avaliadas, as de Ni-Cr e Co-Cr apresentaram maiores valores de RUMC (71,32 e 71,28, respectivamente) que o titânio cp (49,23); sendo que entre elas não houve diferença estatística. Não houve interação entre os fatores avaliados. De acordo com a MO, houve predomínio de fraturas mistas. Segundo a MEV, os espécimes de Ni-Cr e titânio sinterizados a vácuo apresentaram maior rugosidade de superfície do que os sinterizados em argônio. Para a liga de Co-Cr não houve diferença na topografia de superfície. A sinterização em argônio influenciou negativamente a RUMC dos pares metalocerâmicos analisados. / The aim of this study was to evaluate the effect of firing atmospheres: vacuum and argon on the bond strength of ceramic to Ni-Cr (Fit Cast SB), Co-Cr (Star Loy C) and commercially pure titanium (Tritan) alloys. 60 wax/acrylic resin cylinder patterns (8 mm high and 5 mm in diameter) were prepared on a plastic custom mold for metalceramic bond strength (MCBS) test. The patterns were invested in phosphated investment and manipulated on vacuum. The rings were placed in a furnace to burn out patterns and thermally expand the molds. Then, the rings of Ni-Cr and Co-Cr were placed in an electronic machine to cast. The rings related to titanium were positioned in the casting machine with a voltaic arc. After the rings have cooled, the castings were divested manually and abraded with aluminum oxide particles (100 μm). Then, the cylinders were prepared for applying of the ceramic veneering disks. The ceramic was applied and fired in vacuum and argon atmospheres. IPS-Classic ceramic was used for alternative alloys and for titanium, Triceram ceramic. Then, the cylinders composed of metal and ceramic disk (5 mm diameter and 2 mm height) (n=10) were submitted to metal-ceramic bond strength (MCBS) shear tests on an universal testing machine with load cell of 500 Kg at a crosshead speed of 0.5 mm/min. After the tests, there were made fracture analysis by optic microscopy (OM) and scanning electron microscopy (SEM). The MCBS data (MPa) were statistically analyzed by the ANOVA and Tukey test (α=0.05). The results indicated that the vacuum firing (76.58) promoted higher MCBS values than argon firing (51.31). Among the metals, Ni-Cr and Co-Cr alloys presented higher MCBS (71.32 e 71.28, respectively) than titanium (49.23); between two base alloys there was no statistical difference. There was no interaction between the evaluated factors. According to MO analysis, there was predominance of mixed fractures. According SEM, the Ni-Cr and titanium specimens submitted to vacuum presented higher surface roughness than the specimens submitted to argon. For Co-Cr, there was no difference of surface topography. The argon firing influenced negatively the MCBS of metal-ceramic evaluated pairs.
|
Page generated in 0.1276 seconds