• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 561
  • 15
  • 15
  • 14
  • 14
  • 10
  • 7
  • 3
  • 3
  • 3
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 574
  • 574
  • 574
  • 287
  • 281
  • 265
  • 66
  • 64
  • 63
  • 63
  • 55
  • 55
  • 51
  • 51
  • 49
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
361

Estudo anatômico descritivo dos órgãos genitais masculinos do macaco-prego (Cebus apella Linnaeus, 1758) / Descriptive anatomical study of male genital organs of the tufted capuchine monkey (Cebus apella Linnaeus,1758)

Teixeira, Dulcinea Gonçalves 19 December 2005 (has links)
A Anatomia comparada de mamíferos é tema de grande interesse em pesquisas e tem como objetivo buscar conhecimentos que possam auxiliar o entendimento do binômio unidadevariedade. O conhecimento da Anatomia de qualquer animal silvestre é de importância capital para a sua preservação e proteção (RIBEIRO, 2002). Os primatas do novo mundo estão distribuídos na Região Neotropical das Américas Central e do Sul, (RYLANDS; MITTERMEIER; RODRÍGUEZ-LUNA, 1997). O Cebus apella, animal das matas do continente sul-americano, geogra. camente distribuído por quase todo o Brasil, adapta-se bem à vida em cativeiro, onde se reproduz com facilidade (HILL, 1960). O estudo da macro- e micro-anatomia dos órgãos genitais masculinos do macaco Cebus apella é de suma importância para estabelecer os parâmetros morfológicos comparativos com outros primatas. Neste estudo, foram utilizados oito exemplares de macacos Cebus apella, machos, adultos (de aproximadamente sete anos de idade). Estabeleceu-se um padrão anatômico da espécie, e os resultados então obtidos permitem discutir a sua correlação morfo-funcional. Os dados do Cebus apella foram comparados aos de outros primatas já estudados (chimpanzé, gorila, babuíno, rhesus e outros). / Comparative Anatomy of mammals is theme of relevant interest in researches and has the aim to achieve knowledge which could help the understanding of the unit-variety binomial. The knowledge of the Anatomy of any wild animal is of capital importance for his preservation and protection (RIBEIRO, 2002). New world primates are distributed in the Neotropical Region of the Central and South America (RYLANDS; MITTERMEIER; RODRÍGUEZ-LUNA, 1997). The Cebus apella, animal of the South American continent forests, geographically distributed for almost the whole Brazil, is well adapted to the captive life, where reproduces with easiness (HILL, 1960). The macro and micro-anatomical study of the male genital organs of the monkey Cebus apella is of great importance to establish the comparative morphologic parameters with other primates. In this study, eight adult male Cebus apella monkeys (about seven years old) were used and an anatomical pattern was established for the specie. The obtained data allow discussing his morfofunctional correlation. Results for the Cebus apella monkey were compared with that ones of other primates already studied (chimpanzee, gorilla, baboon, rhesus and others).
362

Estudo da interface Ti-6Al-4V/TiO2 por microscopia eletrônica de varredura. / Study of the Ti-6Al-4V/TiO2 interface by scannig electron microscopy.

Bento, Carlos Alberto da Silva 10 August 2000 (has links)
A liga Ti-6Al-4V tem sido usada com sucesso como biomaterial com aplicações nos campos da odontologia e ortopedia. As características da liga Ti-6Al-4V que a tornaram um material interessante são sua boa resistência à corrosão em meio biológico, combinada com um excelente grau de biocompatibilidade. Os efeitos biológicos a longo prazo dos íons metálicos resultantes da lenta lixiviação dos implantes de titânio não estão completamente entendidos. É conhecido que os íons titânio são considerados agentes químicos cancerígenos, os íons alumínio causam desordem neurológicas e os íons vanádio estão associados com distúrbios enzimáticos, entre outros problemas. O recobrimento das ligas de titânio por óxido de titânio (TiO2) pode atuar como uma barreira química para os íons lixiviados da superfície metálica da liga, além deste óxido ser um bom osseoindutor. O processo de aspersão térmica é amplamente empregado na aplicação de recobrimentos por óxidos. Uma vez que este processo acontece em altas temperaturas, onde partículas fundidas ou semi-fundidas aderem ao substrato, pode ocorrer difusão localizada. O objetivo deste estudo é caracterizar a interdifusão dos elementos de liga através das camadas superficiais do sistema Ti-6Al-4V/TiO2. Os recobrimentos de TiO2 foram preparados pela técnica de aspersão por plasma. A zona recoberta mostrou pequena porosidade distribuída por toda a camada e algumas trincas radiais. Adicionalmente, uma grande quantidade de buracos foi observada na região entre-camadas. Neste trabalho, a interface Ti-6Al-4V/TiO2 foi estudada por microscopia eletrônica de varredura. Os perfis de difusão do Ti, Al, V e O nas camadas superficiais da amostra recoberta foram obtidos por microanálise semi-quantitativa por energia dispersiva de raios-X. A caracterização química superficial do lado substrato depois da deposição de TiO2 mostrou a formação localizada de TiO. Na região entre-camadas foram observados os perfis de difusão característicos com forma de S para o Ti, V e O. O perfil de difusão do Al mostrou um pico na região entre-camadas indicando um acúmulo de Al2O3 nos buracos presentes nesta zona. O TiO2 foi identificado como o maior constituinte no lado revestimento. Pequenas quantidades de Al e V foram também detectadas homogeneamente distribuídas dentro do depósito. A presença do Al e V (metais tóxicos) na superfície externa do depósito indica que estes metais não competem com a oxidação da camada depositada indicando um efeito desmascarante da superfície da liga metálica pelo óxido superficial TiO2. / Ti-6Al-4V alloy has been used with some success as biomaterial with applications in the field of dentistry and orthopaedics. The features with make the Ti-6Al-4V alloy such an interesting material are its good corrosion resistance in the biological environment, combined with an excellent degree of biocompatibility. The long-term biological effects of the slowly leaching of metal ions from titanium implants are not completely understood. It is known that the titanium ions are considered chemical carcinogen, aluminium ions cause neurological disorders and, vanadium ions are associated with irreversible enzymatic disturbance, among other problems. Titanium oxide (TiO2) coatings on titanium alloys can act as a chemical barrier for ions leaching from the metallic alloy surface, beside the fact that this oxide is a very good osteoinductor. The thermal spray process is widely used to apply oxide coatings. Once this is a high temperature process where molten or semi-molten particles impinge upon the substrate, localized diffusion can occur. The aim of this study is characterize the inter-diffusion of the alloying elements through the surface layers of the system Ti-6Al-4V/TiO2. The TiO2 coatings were prepared by the plasma spray technique. The coated zone showed some porous distributed in all layer and a few radial cracks. Additionally, large amount of holes were observed in the interlayer region. In this work, the interface Ti-6Al-4V/TiO2 was studied by scanning electron microscopy. Diffusion profiles of Ti, Al, V and O in the surface layers of coated samples were measured by semi-quantitative energy dispersive X-ray microanalysis. Chemical surface characterization of the substrate side after the TiO2 deposition showed the localized formation of TiO. At the interlayer region was observed the characteristic S shape diffusion profiles for Ti, V and O. The Al diffusion profile showed a peak in the interlayer region indicating anaccumulation of Al2O3 into the holes present in this zone. TiO2 was identified as the major component in the coating side. Small amounts of Al and V were also detected homogeneously distributed inside the deposit. Presence of Al and V (toxic metals) on the external surface of the deposit indicated that these metals did not compete with the oxidation of the deposited layer indicating a non-masking effect of metallic alloy surface by the TiO2- surface oxide.
363

Comparação in vitro de parâmetros para fotoativação de restaurações em resina composta por meio de microdureza e microscopia eletrônica de varredura / In vitro comparison of parameters for photoactivation of composite resin restorations using hardness and scanning electron microscopy

Shimokawa, Carlos Alberto Kenji 13 September 2013 (has links)
Este estudo in vitro teve como objetivo a comparação de diferentes protocolos para fotoativação de restaurações em resina composta por meio de teste de microdureza e análise da adaptação marginal com microscopia eletrônica de varredura. Foram confeccionadas restaurações de 2mmx4mmx2mm com a resina composta Premisa (Kerr) em 30 dentes bovinos. Durante o procedimento restaurador, o método de fotoativação teve variação, sendo um grupo ativado com o método contínuo (grupo controle) durante 20 segundos, utilizando o fotoativador Elipar Freelight 2; outro grupo utilizou o mesmo equipamento fotoativador, com variação da distância da ponta ativadora, a fim da promoção de um método soft-start (grupo soft-start), tendo distância inicial de 6mm por 20 segundos, seguido de distância mínima por mais 10 segundos; e um terceiro grupo utilizou a tecnologia PLS (grupo DEMI), fornecida pelo equipamento DEMI, que fornece uma luz pulsada e permite a polimerização adequada de uma resina composta em 5 segundos (segundo o fabricante). Após 24 horas de restaurados, mantidos em estufa a 37ºC, os dentes foram seccionados no sentido inciso cervical resultando em 60 corpos de prova, sendo metade deles utilizados em cada teste (N=10). As metades tiveram as superfícies correspondentes ao corte transversal lixadas até a obtenção de superfícies planas e polidas, sendo que 30 delas foram selecionadas aleatoriamente para o teste de microdureza Knoop em 3 diferentes profundidades e as outras 30 metades foram replicadas em resina epóxica para leitura em microscopia eletrônica de varredura. Com as imagens obtidas foram feitas medidas de porcentagem de perímetro de restauração com desadaptação marginal e largura da maior fenda encontrada. Foram aplicados testes estatísticos de análise de variância split plot para os resultados de dureza e one way para a adaptação marginal. Em relação à dureza, os testes mostraram não haver diferença estatisticamente significante entre os grupos avaliados, enquanto houve diferença nas diferentes profundidades (p<0,0001), sendo a dureza na região profunda maior do que na média, que foi maior do que na superficial. Para a adaptação marginal, os testes não mostraram diferença estatisticamente significante para a largura de maior fenda encontrada entre os grupos controle e DEMI, somente o grupo soft-start foi diferente dos outros grupos (p=0,0064), tendo ele os menores valores. Apesar de a porcentagem de perímetro com desadaptação marginal ter apresentado valores com grandes valores de desvio padrão, foi encontrada diferença estatisticamente significante entre os grupos controle e DEMI, mas não entre os grupos DEMI e soft-start. O teste de correlação de Pearson demonstrou correlação linear positiva entre largura da maior fenda encontrada e porcentagem de perímetro com desadaptação marginal. Foi possível a conclusão de que o protocolo de fotoativação soft-start melhorou a adaptação marginal das restaurações em resina composta, sem alterar a dureza do material; o equipamento fotoativador DEMI, com a utilização da tecnologia PLS, teve resultados sem diferença estatisticamente significante na avaliação da adaptação marginal, quando comparados ao grupo controle; nenhum dos protocolos de fotoativação testados causou alteração na dureza da resina composta fotoativada, quando comparadas entre si, havendo aumento dessa propriedade conforme houve aumento da profundidade. / This in vitro study aimed to compare different protocols for the photoactivation of composite resin restorations using microhardness test and analysis of marginal adaptation with scanning electron microscopy. Restorations with 2mmx4mmx2mm were made in 30 bovine teeth using the composite resin Premisa (Kerr). During the restorative procedure, the polymerization method had change, being one group activated with the continuous method (control group) for 20 seconds using the curing unit Elipar Freelight 2, another group used the same curing unit equipment, varying the distance from the activator tip in order to promote a soft-start method (soft-start group), with initial distance of 6mm for 20 seconds, followed by minimum distance for 10 seconds, and a third group used technology PLS (DEMI group) supplied from the DEMI, which provides a pulsed light and allows an adequate polymerization of a resin composite in 5 seconds (according to manufacturer). 24 hours after restoration, maintained at 37 ° C, the teeth were sectioned incisocervical towards resulting in 60 specimens, half of them being used in each test (N = 10). The halves were sanded on the transversal section surfaces to obtain flat and polished surfaces, of which 30 were randomly selected for Knoop microhardness testing in 3 different depths and the other 30 halves were replicated in epoxy resin for microscopy scanning electron reading. Measures of percentage of perimeter with marginal desadaptation and width of the largest slot found were made with the obtained images. Split plot analysis of variance tests were applied to hardness results and one way to the marginal adaptation. Regarding the hardness, tests showed no statistically significant difference among the groups, while there were differences at different depths (p<0,0001), being the hardness of the deep region highest than the medium, which was higher than the superficial. For marginal adaptation, tests showed no statistically significant difference for the width of the largest slot found between the control group and DEMI, only the soft-start group was different from the other groups (p=0,0064), having the lowest values. Despite the large standard deviations shown by the percentage of perimeter with marginal desadaptation, statistically significant difference was found between the control and DEMI, but not between groups DEMI and soft-start. The Pearson correlation test showed positive linear correlation between the width of the largest slot found and the percentage of perimeter with marginal desadaptation. It was possible to conclude that the soft-start photoactivation protocol improved the marginal adaptation of composite resin restorations, without changing the hardness of the material; DEMI curing unit equipment, using PLS technology, showed no statistically significant difference in the evaluation of marginal adaptation, comparing with the control group; none of the protocols tested photoactivation caused change in hardness of composite resin when compared to each other, with an increase of this property as the depth increased.
364

\"Estudo da influência de instrumentos e técnicas alternativas de preparo cavitário na resistência de união de sistema adesivos à dentina\" / Study of the influence of alternative tools and techniques of cavity preparation on teh bond strength of adhesive system to dentin

Cardoso, Marcio Vivan 15 January 2007 (has links)
A atual tendência ao desenvolvimento de uma odontologia minimamente invasiva tem sido responsável pela introdução de instrumentos e técnicas alternativas de preparo cavitário. Porém, tais tecnologias deveriam não somente preencher os requisitos de uma odontologia conservadora, mas também preparar as paredes da cavidade para o tratamento restaurador adesivo subseqüente. Assim, o objetivo deste estudo foi testar a hipótese nula de que: 1) tanto técnicas convencionais quanto técnicas alternativas de preparo cavitário são capazes de produzir um substrato dentinário receptivo à adesão de sistemas autocondicionantes; e 2) A efetividade adesiva de sistemas autocondicionantes não é influenciada pela interposição da camada de esfregaço. Cem molares humanos íntegros foram aleatoriamente divididos em 20 grupos de acordo com o adesivo e a técnica ou instrumento utilizado. Superfícies planas de dentina média oclusal foram preparadas com instrumento rotatório diamantado convencional (IR); fratura; instrumento rotatório CVD (IRCVD); instrumento ultra-sônico CVD (IUCVD); e laser de Er,Cr:YSGG .Um adesivo condicione-e-lave (Optibond FL/OB) e três autocondicionantes (Adper Prompt L-Pop/AP, Clearfil SE Bond/SE e Clearfil S3 Bond/S3) foram empregados. Os espécimes foram construídos com o compósito Z100/3M ESPE. A resist6encia adesiva foi determinada por meio de teste de microtração após 24 h de estocagem em água a 37oC. Amostras adicionais foram processadas para análise em MEV quanto às características morfológicas apresentas após o preparo das superfícies dentinárias em cada caso. O teste de Kruskal-Wallis (p<0,05) determinou que os grupos preparados com IRCVD, IUCVD e laser apresentaram menores valores de resistência adesiva quando comparados aos grupos controle (IR e fratura). Além disso, os adesivos de menor acidez (SE e S3) foram mais eficientes quando aplicados em dentina fraturada. Concluiu-se que o uso de instrumentos e técnicas alternativas de preparo cavitário comprometeu a adesão à dentina e que a camada de esfregaço influencia de forma negativa a adesão de sistemas autocondicionantes suaves. / The current trend toward minimal invasive dentistry has introduced alternative cavity preparation techniques. However, these technologies should not only fulfill the requirements of a conservative philosophy, but also prepare the cavity walls for the subsequent bonding restoration. The purpose of this study was to assess the null hypotheses that: (1) both conventional and alternative cavity preparation techniques are equally receptive to adhesion; and (2) bonding effectiveness of mild adhesives is not influenced by smear layer (SL) interposition. Eighty sound human molars were divided into 20 groups according to adhesive and cavity preparation technique. Flat mid-occlusal dentin surfaces were prepared with regular diamond bur (DB), scalpel blade (SB), CVDentus bur in high speed turbine (CB), CVDentus tip in ultrasound (CT), and Er,Cr:YSGG laser (L). One etch-and-rinse (Optibond FL (OB)) and three self-etch systems (Adper Prompt L-Pop (AP), Clearfil SE Bond (SE) and Clearfil S3 Bond (3S)) were employed. Specimens were built up with Z100/3M ESPE composite. The microtensile bond strength was determined after 24h of storage in water at 37oC. Additional samples were processed for SEM analysis on morphological aspects in each situation. Kruskal-Wallis test (p<0,05) determined that groups prepared with CB, CT and L presented lower ?TBS values than the control groups (DB and SB), and that adhesives with lower acidity (SE and 3S) were more effective when applied on fractured surfaces (SB). It was concluded that the use of alternative techniques for cavity preparation caused damages to dentin surface, compromising the adhesion to this substrate. Moreover, the bonding effectiveness of mild adhesives was improved by SL absence.
365

Efeito da atmosfera de sinterização na resistência de união da porcelana com ligas de níquel-cromo e cobalto-cromo / Effect of firing atmosphere on metal ceramic bond strength of nickel-chromium and cobalt-chromium

Alves, Luciana Mara Negrão 11 February 2015 (has links)
O objetivo deste trabalho foi avaliar a influência de dois diferentes ambientes de sinterização (vácuo e argônio) sobre a resistência da união metaloceramica (RUMC) envolvendo diferentes ligas de metais básicos (Co-Cr e Ni-Cr) e uma porcelana odontológica, através do teste de flexão de três pontos, conforme preconizado pela ISO 9693:2012. As ligas estudadas foram Co-Cr: Remanium e Keragen e Ni-Cr: Verabond II e uma liga experimental &ldquo;SR&rdquo; . Foram obtidos 80 corpos de prova em forma tiras metálicas medindo 25 X 0,5 X 5 mm. Para esse ensaio, portanto, o número de corpos de prova foi o produto de 4 ligas x 2 condições de atmosfera de sinterização x 10 repetições. A parte metálica de todos os corpos de prova após a fundição foram usinados e jateados com óxido de alumínio (150&mu;m) e a seguir tratados como preconizado pelo fabricante. O corpo cerâmico, com o auxílio de uma matriz, foi confeccionado na área central da tira, 8,0 X 3,0mm, apresentando 1,1mm de espessura, sendo 10 corpos de prova em cada ambiente de sinterização para cada tipo de liga. Os corpos de prova obtidos foram submetidos aos testes de flexão de três pontos na Máquina de Ensaios Mecânicos (EMIC) com velocidade de 1.0mm/min. para determinação da RUMC. Os valores da carga de ruptura obtidos em quilograma-força (Kgf) foram convertidos para Newton (N) e a partir disso foi calculado o valor da RUMC para cada corpo de prova, considerando o coeficiente de elasticidade de cada liga e a espessura exata de cada corpo de prova. Os dados obtidos (MPa) foram submetidos à análise estatística (ANOVA) e Bonferroni. A Análise de Variância indicou diferença estatisticamente significante para os fatores de variação ambiente (P=0,00), liga (P=0,009) e entre as interações ambiente de sinterização e liga (P=0,000). Na sinterização a vácuo as ligas Keragen, SR e Verabond II apresentaram maiores valores de RUMC do que o argônio. Para a liga Remanium, não houve diferença entre a sinterização em argônio e a sinterização a vácuo. Dentre os grupos sinterizados no argônio não houve diferença estatisticamente significante entre as ligas. Entretanto, no vácuo a liga Remanium apresentou menor valor de RUMC do que as demais ligas, que não apresentaram diferença entre si. Os corpos de prova, após os ensaios de flexão, foram submetidos a análise em microscopia optica, MEV e EDS para avaliar e registrar tipo de falha que sofreram. De acordo com a MO, houve predomínio de fraturas mistas. Os corpos de prova de Co-Cr (Remanium e Keragen), independende do ambiente de sinterização, apresentaram uma fina camada de óxido no corpo cerâmico, o que foi comprovado pelo EDS, com maior presença de íons Cr nessas regiões, já os grupos SR e Verabond II, apresentaram maior quantidade de opaco aderido em suas tiras metálicas. A MEV comprovou os achados da MO, onde foi possível encontrar grandes ilhas de material cerâmico nas ligas de Ni-Cr. A sinterização em argônio influenciou negativamente a RUMC dos pares metalocerâmicos confeccionados em Ni-Cr e na liga Keragem / The aim of this study was to evaluate the influence of two different firing atmosphere (vacuum and argon) on the metalceramic bond strength (MCBS) involving different base metal alloys (Co-Cr and Ni-Cr) and a dental porcelain through three-point bending test, as recommended by ISO 9693: 2012. Co-Cr alloys studied were: Remanium and Keragen and Ni-Cr: Verabond II and an experimental alloy \"SR\". 80 specimens were obtained in metallic form strips measuring 25X0.5 X 5.0 mm. For this test, therefore, the number of specimens was the product of 4 x 2 alloy sintering atmosphere conditions x 10 replicates. The metal portion of all specimens were machined after casting and sandblasted with aluminum oxide (100&mu;m) and then treated as recommended by the manufacturer. By using a matrix, the ceramic body was made in the central area of the strip, 8.0 x 3.0 mm, it was made 1.1 mm thickness, 10 specimens in each sintering environment for each type of alloy. The specimens obtained were tested for three-point bending in a universal testing machine with a speed of 1.0mm / min. to determine MCBS. The values of the tensile strength obtained in kilogramforce (kgf) were converted into Newton (N) and from this the value of MCBS for each specimen was calculated, considering the coefficient of elasticity of each league and the exact thickness of each specimen. The data (MPa) were subjected to statistical analysis (ANOVA) and Bonferroni. The analysis of variance indicated statistically significant difference for the environment factors of firing atmosphere (P = 0.00) and alloy (P = 0.009). There was a statistically significant difference in the interaction factors for firing atmosphere x alloy (P = 0.000). In the vacuum Keragen, SR and Verabond II alloys showed higher MCBS than argon. To Remanium, there was no difference between the sintering in argon and vacuum. Among the groups sintered in argon there was no statistically significant difference between the alloys. However, the vacuum Remanium showed the lowest RUMC than other alloys, which showed no difference between them. The specimens after the bending tests, were subjected to analysis in optical microscopy, SEM and EDS to assess and record type of failure they suffered. According to the MO was predominantly mixed fractures. Specimens of Co-Cr (Remanium and Keragen) independende the atmosphere firing, showed a thin oxide layer on the ceramic body, which was confirmed by EDS, with greater presence of Cr in these regions, since the SR groups and Verabond II, presented more opaque stuck in their metal strips. SEM confirmed the findings of MO, where it was possible to find large islands of ceramic material in Ni-Cr alloys. The sintering in argon negatively influenced MCBS metalceramic of pairs made of Ni-Cr alloy and Keragem
366

Efeito das pastilhas higienizadoras efervescentes à base de peróxido alcalino em liga metálica de cobalto-cromo / Effect of alkaline peroxide-effervescent tablets on the surfaces of the cobalt-chromium alloys

Vasconcelos, Glenda Lara Lopes 17 December 2015 (has links)
A higienização das próteses é de fundamental importância para a longevidade do tratamento reabilitador. Entretanto, é necessário analisar os efeitos que os higienizadores podem causar nas superfícies que compõem uma prótese. Deste modo, o objetivo deste estudo foi avaliar os efeitos de pastilhas efervescentes à base de peróxido alcalino em liga de cobalto cromo (Co-Cr), utilizada em Prótese Parcial Removível (PPR). A partir de uma matriz metálica, padrões de cera em forma de disco (12 mm x 3 mm) foram confeccionados para posterior fundição. Os espécimes metálicos (n=16) foram imersos nas soluções: água deionizada (controle), Polident 3 minutes®, Steradent®, Efferdent®, Polident for Partials® e Corega Tabs®. Foi realizada a análise da rugosidade (n=10) por meio de rugosímetro, antes (t0) e após 5 períodos de simulação de ½, 1, 2, 3, 4 e 5 anos de imersão nos higienizadores. Foram realizadas análises complementares quantitativas da liberação de íons (n=5) de cobalto (Co), cromo (Cr) e molibdênio (Mo) em cada solução e análises qualitativas em um espécime de cada grupo, por meio de Microscopia Eletrônica de Varredura (MEV) e Espectrometria de Energia Dispersiva de Raios X (EDS). A distribuição dos dados de rugosidade (&mu;m) apresentou-se não normal. Foi utilizada estatística não-paramétrica (&alpha;=0,05). Tanto para o fator solução (Kruskall Wallis, ½ ano (p=0,900), 1 ano (p=0,277), 2 anos (p=0,227), 3 anos (p=0,086), 4 anos (p=0,657) e 5 anos (p=0,856), como para o fator tempo (Friedman, p=0,137) não houve diferença significante. Com relação à liberação de íons (&mu;g/L), a distribuição dos dados apresentou-se normal. De acordo com a estatística (&alpha;=0,05, ANOVA e teste de Tukey), Corega Tabs®, Efferdent® e água deionizada promoveram maior liberação de íons Co do que o Steradent® (p=0,003). Quanto aos íons Cr (p=0,000), Corega Tabs® propiciou maior liberação quando comparado a água deionizada, Steradent® e Polident 3 minutes®. Em relação aos íons Mo (p=0,001), o Efferdent® promoveu maior liberação. No MEV pode-se verificar que as soluções não apresentaram efeitos deletérios sobre as superfícies. Conclui-se que todas as pastilhas avaliadas não ocasionaram danos, entretanto, Steradent® foi a que propiciou menor liberação de íons, sendo indicada com maior segurança para higienização de superfícies metálicas de PPR. / The hygiene care of the removable dentures is of most importance for the longevity of the rehabilitation treatment. However, it is necessary to analyze the effects that denture cleansers can cause on the surfaces of prosthesis. Thus, the aim of this study was to evaluate the effect of alkaline peroxide-effervescent tablets on the surfaces of the cobalt-chromium alloys (Co-Cr), used in removable partial dentures (RPD). Circular specimens (12 mm x 3 mm) were fabricated with cobalt-chromium alloys. The specimens (n= 16) were immersed in the following solutions: deionized water (control), Polident 3 minutes&trade;, Steradent&trade;, Efferdent&trade;, Polident for Partials&trade; and Corega Tabs&trade;. The surface roughness (n=10) was analyzed with a surf-test analyzer, before and after 5 periods that corresponds to the simulation of ½, 1, 2, 3, 4 and 5 years of immersion in the cleansers. As complementary analysis, it was performed a quantitative study of ions release (n=5) for cobalt (Co), chromium (Cr) and molybdenum (Mo) in each solution and qualitative analysis with scanning electron microscopy (SEM) associated to Energy-dispersive X-ray spectroscopy (EDS). The results of surface roughness had presented no normal. In nonparametric statistics (&alpha; = 0.05), both of the solution factor Kruskall Wallis, ½ year (p=0.900), 1 year (p=0.277), 2 years (p=0.227), 3 years (p=0.086), 4 years (p=0.657) and 5 years (p=0.856), such as time factor (Friedman, p = 0.137), there was no significant difference. The results of ionic release presented a normal distribution and they were submitted to ANOVA (p=0.05) and Tukey test. The solutions Corega Tabs®, Efferdent® and deionized water presented greater Co ionic release than Steradent® (p=0.003). For Cr ions (p=0.000), Corega Tabs® had greater ionic release than deionized water, Steradent® and Polident 3 minutes®. Regarding Mo ions (p=0.001), Efferdent® showed greater release. With SEM, it was possible to verify that the solutions showed no deleterious effects on the specimen surfaces. It was concluded that no deleterious effects on metal surface was caused, however, Steradent® presented the smallest ionic release, and can be indicated more safely for cleaning metal surfaces of RPD.
367

Análise morfológica da dentina irradiada pelo laser de Er:YAG (SSP) com diferentes larguras de pulso / Effect of Er:YAG (SSP) laser pulse widths on dentin - morphological analysis

Trevelin, Lívia Tosi 30 January 2015 (has links)
Este estudo se propôs a analisar as características morfológicas da dentina humana irradiada com laser de Er:YAG utilizando diferentes larguras temporal de pulso nos protocolos de preparo cavitário e pré-tratamento da dentina. Foram utilizados 18 molares humanos que foram seccionados no sentido mésio-distal e amelocementário obtendo-se um disco plano de dentina. Em seguida foram lixados com uma sequência decrescentes de lixas para padronizar os espécimes em 2mm de espessura. Os grupos experimentais foram compostos a partir de 2 fatores de variação: 1) indicação clínica - preparo cavitário (E=200mJ/20Hz), e pré-tratamento (E=80mJ/2Hz); e 2) largura temporal de pulso - 50, 300 e 600µs. Assim formaram-se 6 grupos experimentais com (n=3): G1(E=200mJ/20Hz/50µs); G2(E=200mJ/20Hz/300µs); G3(E=200mJ/20Hz/600µs); G4(E=80mJ/2Hz/50µs); G5(E=80mJ/2Hz/300µs); G6(E=80mJ/2Hz/600µs). Os espécimes foram irradiados com o laser de Er:YAG com comprimento de onda de 2,94µm, de modo não contato, com um distância de 7mm do feixe de saída, sob irrigação de 60ml/min de água e 40ml/min de ar. Após a irradiação, os espécimes foram processados e destinados à avaliação descritiva das imagens obtidas em Microscopia Eletrônica de Varredura (MEV), nos diferentes grupos experimentais. A análise morfológica dos grupos irradiados revelou uma superfície irregular, ausência de smear layer que expõe a abertura dos túbulos dentinários, dentina peritubular evidente e, sem indícios de carbonização e derretimento para todos os protocolos utilizados. Os resultados deste estudo in vitro mostraram que a irradiação com o laser de Er:YAG promoveram um padrão morfológico microrretentivo característico de ablação para todos os grupos testados e os grupos G1 e G4, que utilizaram a menor largura temporal de pulso (50 ?s), apresentaram uma superfície mais rugosa quando comparados aos demais grupos. Por fim, podemos concluir que a largura temporal de pulso influência nas características morfológicas da dentina irradiada nas diferentes indicações clínicas testadas, preparo cavitário e pré-tratamento. A menor largura de pulso (50 µs) produz uma morfologia mais irregular quando comparada as maiores larguras de pulsos (300 e 600 µs). / This study evaluated the morphological characteristics of Er:YAG laser irradiated dentin using different temporal pulses width on the protocols of cavity preparation and dentin pretreatment. Eighteen human molars were cut longitudinally in a mesiodistal direction and amelocemental junction providing dentin disks. Samples were polished in a decreasing silicon carbide paper to obtain standard 2mm thick disks. The experimental groups were divided by two variables: 1) clinical protocol - cavity preparation (E=200mJ/20Hz) and pretreatment (E=80mJ/2Hz); and 2) temporal pulse width - 50, 300 and 600µs. Therefore, six experimental groups were (n=3): G1(E=200mJ/20Hz/50µs); G2(E=200mJ/20Hz/300µs); G3(E=200mJ/20Hz/600µs); G4(E=80mJ/2Hz/50µs); G5(E=80mJ/2Hz/300µs); and G6(E=80mJ/2Hz/600µs). The samples were irradiated with the Er.YAG laser using wave-length of 2.94µm, in a non contact mode at a focal distance of 7mm from the target point under continuous water spray of 60-40ml/min. After the irradiation, the samples were processed and evaluated by scanning electron microscopic evaluation (SEM). The morphological analysis on the irradiated groups showed an irregular dentin surface, without smear layer, exposed dentinal tubules apertures, evidenced peritubular dentin, without carbonization and melting signs for all groups. A microretentive morphological pattern, characteristic of the ablation process could be observed in all groups. However, groups G1 and G4, that used 50?s of temporal pulse width, presented a greater irregularity when compared to other groups. In conclusion, the temporal pulse width interfere on the morphological characteristic of the irradiated dentin, regardless of clinical protocol, cavity preparation and pretreatment. The shorter the pulse width (50µs), the greater the surface irregularity.
368

Caracterização molecular e morfológica de isolados brasileiros do gênero Euglena. / Molecular and morphological characterization of Brazilian isolates of the genus Euglena.

Martins, Adriana Vieira de Castro 12 February 2009 (has links)
Neste estudo foram isolados e caracterizados flagelados de 20 amostras de solo e água do Brasil classificados no gênero Euglena por parâmetros taxonômicos tradicionais, e distribuídos em 5 grupos de acordo com características morfológicas. Análises filogenéticas do gene SSUrDNA das 20 amostras resultou em 25 seqüências posicionadas nos grupos A2 e A3 do gênero Euglena definidos em estudos anteriores, separando as seqüências obtidas em 7 clados distintos, revelando uma maior diversidade que a obtida por parâmetros taxonômicos tradicionais. A fim de resolver os relacionamentos intra-específicos do grupo A3, realizamos uma análise filogenética restrita deste grupo, que apresentou árvores congruentes e subclados bem suportados. Representantes de cada espécie foram analisados por microscopia eletrônica de varredura, revelando dois padrões principais de estrias e poros da película. Os isolados caracterizados neste estudo são os primeiros do Brasil estabelecidos em cultura, validados por análises filogenéticas e morfologicamente caracterizados. / In this study we isolated and characterized flagellates from 20 soil and water samples of Brazil, classified in the genus Euglena based on traditional taxonomic parameters and distributed in 5 groups according to morphological characteristics. Phylogenetic analyses of the SSUrDNA of the 20 samples resulted in 25 sequences that where positioned in previously defined groups A2 and A3 of the genus Euglena, separating the obtained sequences in 7 distinct clades, revealing a larger diversity than defined by traditional taxonomic parameters. To better resolve the intra-specific relationships of group A3, we conducted a phylogenetic analyses restricted to this group, generating congruent trees and well supported sub-clades. A representative of each species was selected and analyzed by scanning electron microscopy, revealing two major patterns of strip and pellicle pores. The isolates characterized in this study are the first in Brazil to be established in culture, validated by phylogenetic analyses and morphologically characterized.
369

Um novo algoritmo de granulometria com aplicação em caracterização de nanoestruturas de silício. / A new correlation-based granulometry algorithm with application in characterizing porous silicon nanomaterials.

Maruta, Ricardo Hitoshi 14 October 2011 (has links)
Granulometria é o processo usado para medir objetos de diferentes tamanhos em imagens de material granular. Frequentemente algoritmos baseados em morfologia matemática ou detecção de arestas são utilizados para esta finalidade. Propomos uma nova abordagem para a granulometria utilizando correlações cruzadas com círculos de tamanhos diferentes. Esta técnica é primeiramente adequada para a detecção de objetos de formato circular, mas pode ser estendido para outras formas utilizando outros núcleos (kernels) de correlação. Experimentos mostram que o novo algoritmo é robusto ao ruído e pode detectar objetos com pouco contraste e/ou com sobreposição parcial. Este trabalho também apresenta características quantitativas estruturais da camada de silício poroso, obtidas aplicando o algoritmo proposto em imagens de microscopia eletrônica de varredura (MEV). O novo algoritmo, que chamamos Granul, calcula as áreas e frequências dos poros. Processamentos adicionais utilizando outros algoritmos classificam os poros em circulares ou quadrados. Relacionamos os resultados quantitativos obtidos com o processo de fabricação e discutimos o mecanismo de formação do poro quadrado no silício. O novo algoritmo mostrou-se confiável no processamento de imagens de MEV e é uma ferramenta promissora para controle no processo de formação dos poros. / Granulometry is the process of measuring the size distribution of objects in an image of granular material. Usually, algorithms based on mathematical morphology or edge detection are used for this task. We propose a entirely new approach for the granulometry using the cross correlations with circles of different sizes. This technique is primarily adequate for detecting circular shaped objects, but it can be extended to other shapes using other correlation kernels. Experiments show that the new algorithm is greatly robust to noise and can detect even faint objects and/or objects with partial superposition. This paper also reports the quantitative structural characteristics of the porous silicon layer based on the proposed algorithm applied to Scanning Electron Microscopy (SEM) images. The new algorithm, that we call Granul, computes the size distribution of pores and classifies the pores in circular or square ones. We relate these quantitative results to the fabrication process and discuss the square porous silicon formation mechanism. The new algorithm shows to be reliable in SEM images processing and is a promising tool to control the pores formation process.
370

Perfilometria e microscopia eletrônica de varredura da superfície dentinária após escovação com cremes dentais dessensibilizantes e desafio erosivo com fruta amazônica / Profilometry and scanning electron microscopy of dentin surface after brushing with desensitizing toothpastes and challenge

Rocha, Max Pinto da Costa da 13 December 2012 (has links)
O objetivo deste estudo in vitro foi avaliar o potencial erosivo de suco de fruta amazônica ácida sobre a superfície dentinaria associado ao efeito abrasivo de diversos cremes dentais contendo agentes dessensibilizantes. O trabalho foi dividido em 3 fases distintas: Na fase 1, o valor do pH inicial de diversas frutas amazônicas foi medido utilizando 50 ml de cada suco, obtido de polpa industrializada. Foi utilizado um eletrodo de pH calibrado e a água destilada foi utilizada como controle. Na fase 2, 120 espécimes de dentina bovina foram submetidos a ciclos alternados de desafio abrasivo e erosivo, com a fruta escolhida na fase 1. Os espécimes foram divididos aleatoriamente em Grupo A (Desafio Abrasivo) e Grupo B (Desafio Erosivo e Abrasivo). Cada um destes grupos foram subdivididos em 5 subgrupos: 1: Água Destilada (Controle Negativo), 2: Colgate Tripla Ação (Controle Positivo), e os demais de acordo com o creme dental utilizado 3: Sensodyne Rápido Alívio, 4: Colgate Pró-Alivio e 5: Sensodyne Repair&Protect, (n=9). Na fase 3 foi realizado microscopia eletrônica de varredura para avaliar qualitativamente os espécimes (n=3). - O suco da fruta taperebá (Spondias mombin) apresentou os menores valores de pH, diante disso, foi escolhido como agente erosivo; Os testes de Kruskall Wallis e Teste de Dunn, mostraram que para os grupos nos quais somente a abrasão foi realizada, todos os cremes dentais mostraram comportamentos semelhantes em relação a perfilometria, não havendo diferença estatisticamente significante entre os grupos. Porém, para os grupos nos quais o processo erosivo foi adicionado, observou-se a potencialização do processo abrasivo, sendo que os cremes dentais Sensodyne Rápido Alivio e Colgate Sensitive Pro-Alivio foram os que mostraram menores alterações superficiais no padrão de perfilometria, comparados com o grupo controle negativo. Já os cremes dentais, Colgate Tripla Ação (controle positivo) e Sensodyne Repair&Protect apresentaram-se semelhantes entre si e com uma perda de estrutura dentinaria. mais significante. Conclui-se que o efeito erosivo da fruta amazônica taperebá é fator de grande importância na potencialização do efeito abrasivo, mesmo quando do uso de cremes dentais com agentes dessensibilizantes.. Na análise qualitativa da superfície dentinária em MEV, com exceção do Colgate tripla ação, os demais grupos não apresentaram oclusão tubular após o desafio ácido / The aim of this in vitro study was to evaluate the erosive potential of amazonian fruit juice with or without the abrasive challenge with various toothpastes containing desensitizing agents. The work was divided into three phases: in phase 1, the pH of various Amazonian fruits was evaluated. In step 2 it was performed surface perfilometry of the specimens, and in phase 3 it was evaluated qualitatively the dentin surface. In step 1, the initial pH value of several amazonian fruits was measured using 50 mL of each juice, from industrialized pulp. It was used a calibrated pH electrode, and distilled water was used as control. In step 2, 120 bovine dentin specimens were subjected to alternate cycles of abrasive and erosive challenge, with the fruit chosen in step 1. The specimens were randomly divided into Group A (without erosion) and Group B (with erosion). Each of these groups were divided into 5 groups: 1: Distilled Water, 2: Colgate Tripla Ação, 3: Sensodyne Rápido Alívio, 4: Pro-Alivio, 5: Sensodyne Repair & Protect, (n = 9). In Phase 3 it was conducted scanning electron microscopy to evaluate qualitatively the specimens (n=3). As a result it can be stated that: 1. The juice of the taperebá fruit had the lowest pH values, so it was chosen as the erosive agent; 2. For the groups in which only the abrasion was performed, all toothpastes showed similar behaviors, no statistically significant difference was observed between groups, but for the groups in which the erosion process was added, there was a potentiation of the abrasive process, and the toothpastes showed different profiles. The toothpaste Sensodyne Rapido Alívio Pró-Alívio was the ones that showed lower mineral loss, compared with the negative control group. Colgate Tripla Ação and Sensodyne Repair&Protect were similar among themselves and with a more significant mineral loss. It can be conclude that erosive effect of diet is a factor of great importance in the potentiation of abrasive effect. Clinical studies are essential to determine the dentin hypersensitivity levels after use of toothpaste used.

Page generated in 0.1253 seconds