• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • Tagged with
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação da superfície do esmalte dentário por microscopia eletrônica de varredura após a remoção do bráquete e polimento /

Pignatta, Lilian Maria Brisque. January 2006 (has links)
Orientador: Eduardo César Almada Santos / Banca: José Rino Neto / Banca: Francisco Antonio Bertoz / Resumo: Introdução: a preservação da estrutura de esmalte após a remoção dos acessórios ortodônticos é uma obrigação do clínico. Portanto, procura-se um protocolo de descolagem com bases científicas. Objetivou-se neste trabalho avaliar por Microscopia Eletrônica de Varredura (MEV) a influência de quatro protocolos de remoção de bráquetes e polimento da superfície do esmalte e propor um protocolo que minimizasse os danos na superfície do esmalte. Material e método: doze incisivos permanentes bovinos foram divididos em quatro grupos de acordo com os instrumentos utilizados para a descolagem dos bráquetes e remoção do remanescente adesivo. Os bráquetes foram descolados com o alicate de descolagem reto (Ormco Corp.) nos grupos 1 e 2, e com o instrumento de descolagem Lift-Off (3M Unitek) nos grupos 3 e 4. Os remanescentes adesivos dos grupos 1 e 3 foram removidos com o alicate removedor de resina longo (Ormco Corp.) e dos grupos 2 e 4 com broca de carboneto de tungstênio (Beavers Dental) em alta-rotação com constante refrigeração de água. As superfícies, após cada etapa da descolagem e polimento, foram avaliadas em réplicas de resina epóxica e foram obtidas eletromicrografias com aumento de 50 e 200X em todos os grupos. Resultado: os quatro protocolos de remoção de acessórios ortodônticos e polimento ocasionaram irregularidades no esmalte. Conclusão: a remoção do bráquete com o alicate de descolagem reto, seguido da remoção do remanescente adesivo com broca de carboneto de tungstênio e polimento final com pasta de pedra-pomes foi o procedimento que ocasionou menores danos ao esmalte, sendo o protocolo sugerido para a remoção dos acessórios ortodônticos. / Abstract: Introduction: the preservation of the enamel structure after the removal of the orthodontic accessories is an obligation of the clinical. Therefore, a protocol of debonding with scientific bases is searched. The aim of this work was to evaluate through Scanning Electronic Microscopy (SEM) the influence of four protocols of bracket’s removal and polishing on the enamel and to recommend a protocol that minimized the damages to the enamel surface. Methods: twelve permanent bovine incisors were divided into four groups according to the instruments used to debond and remove of adhesive remnants. The brackets were removed with straight debonding pliers (Ormco Corp.) in the groups 1 and 2, and with Lift-Off debonding instrument (3M Unitek) in the Groups 3 and 4. The adhesive remnants in the groups 1 and 3 were removed with the adhesive removing pliers (Ormco Corp.) and in the groups 2 and 4 with high speed tungsten carbide bur with constant water refrigeration (Beavers Dental). The surfaces, after each step of debonding and polishing were evaluated in replicas of epoxy resin and were obtained electromicrographies with magnification of 50 and 200X in all groups. Results: the four removal protocols of orthodontic accessories and polishing caused irregularities to the enamel. Conclusion: the bracket’s removal with straight debonding pliers, followed by the removal of the adhesive remnants with tungsten carbide bur and final polishing with pumice was the procedure that caused less damage to enamel, being the suggested protocol for removal of orthodontic accessories. / Mestre
2

Avaliação da influência da técnica de fotopolimerização da resina composta e diferentes materiais protetores pulpares na formação de fendas /

Souza, Niélli Caetano de. January 2007 (has links)
Resumo: O objetivo deste estudo foi avaliar a influência da fotopolimerização gradual no deslocamento de materiais protetores pulpares em função da contração de polimerização da resina composta através da formação de microfendas nas interfaces: estrutura dental/material protetor pulpar/ resina composta. Cavidades classe V, com dimensões padronizadas foram preparadas nas faces V e L de 20 terceiros molares humanos, divididos em 4 grupos de acordo com o material protetor pulpar e técnica de fotopolimerização: (1) Ketac Molar Easymix, 3M ESPE - (IVQ) + Fotopolimerização convencional - 850mW/cmø por 20s (FC); (2) IVQ + Fotopolimerização gradual - 100 mW/cm2 até 1000 mW/cm2 por 10s e 1000 mW/cm2 por 10s (FG); (3) Vitrebond 3M ESPE (IVR) + FC; (4) IVR +FG. Todas as cavidades foram restauradas com sistema adesivo Single Bond (3M ESPE) e resina composta híbrida Four Seasons (Ivoclar Vivadent). O aparelho fotopolimerizador utizado foi Optilux 501 (Demetron - Kerr) no modo convenciona e gradual (RAMP). Após ciclagem térmica um segmento longitudinal de 2 mm de espessura foi obtido na porção central de cada restauração e, em seguida, submetidos às etapas de fixação e desidratação em grau ascendente de etanol. A adaptação interna dos materiais à parede axial foi analisada em MEV, com 1000x de magnificação. A análise estatística realizada pela ANOVA a dois critérios de avaliação e pelos testes de Levene e Shapiro-Wilk (p_0,05) mostrou haver significância estatística entre as técnicas de fotopolimerização convencional e gradual (Ramp). Há evidência de que a fotopolimerização convencional produz, em 13 média, fendas maiores do que a fotopolimerização gradual. / Abstract: The aim of this study was to evaluate the influence of gradual photolymerization on the displacement of pulp protective materials due to the resinþs photopolymerization contraction trough the formation of gaps on the following interfaces: dental structure/ pulp protective material/ composite resin. Class V cavities with standardized dimensions were prepared on the buccal and lingual surfaces of 20 human sound third molars, divided into 4 groups according to their pulp protective material and photopolymerization technique:(1) Ketac Molar Easymix, 3M ESPE- (IVQ) + Conventional photopolymerization-850 mW/cm2 for 20 seconds (FC); (2) IVQ + gradual photopolymerization-100 mW/cm2 to 1000 mW/CM2 for 10 seconds and 1000 Mw/CM2 for 10 seconds (FG); (3) Vitrebond 3M ESPE (IVR)+ FC; (4) IVR + FG.All cavities were restored using the adhesive system Single Bond (3M ESPE) and hybrid composite resin Four Seasons (Ivoclar Vivadent). The device used for photopolymerization was the Optilux 501 (Demetron-Kerr) in both conventional and gradual (RAMP) modes. After thermal cycling, a longitudinal segment of 2 mm of thickness was obtained from the central part of every restoration, and submitted to fixation and dehydration with uprising levels of ethanol processes. The internal adaptation of the materials to the axial wall of the preparation was analyzed in 16 SEM with 1,000x of magnification. The statistical analysis was made using two-way ANOVA and Levene and Shapiro-Wilk (p _ 0,05) tests. Results showed statistically significant differences between the gradual (RAMP) and conventional photopolymerization techniques. There are evidences that the conventional technique creates wider gaps than the gradual technique. / Orientador: Alexandre Henrique Susin / Coorientador: Osmir Batista de Oliveira Junior / Banca: Marcelo Ferrarezi de Andrade / Banca: Roselaine Terezinha Pozzobon / Doutor
3

Estudo in vitro da eficácia do gel de EDTA 24% na remoção de "smear layer" e exposição de fibras colágenas da superfície radicular /

Sousa, Cliciane Portela. January 2004 (has links)
Orientador: José Eduardo Cezar Sampaio / Banca: Silvana Regina Perez Orrico / Banca: Joni Augusto Cirelli / Banca: Enilson Antônio Sallum / Banca: Márcio Zafallon Casati / Resumo: O objetivo do presente estudo foi avaliar, por meio da Microscopia Eletrônica de Varredura (MEV), a eficácia do condicionamento químico com o gel de EDTA 24% na remoção de "smear layer" e exposição de fibras colágenas, avaliando-se diferentes marcas comerciais, modos e tempos de aplicação. Dentes humanos extraídos foram desgastados com fresa diamantada para remoção do cemento e raspados com curetas de Gracey 5-6 para formação de "smear layer". Após o seccionamento dentário, as 225 amostras obtidas foram divididas em 5 grupos: I) Soro Fisiológico; II) EDTA 24% (Farmácia Santa Paula); III) EDTA-T 24% (Farmácia Santa Paula); IV) EDTA 24% (Biora); V) EDTA 24% (Biodinâmica). As amostras de cada grupo(n=45) foram divididas em subgrupos (n= 5) e condicionadas nos tempos de 01, 02, 03 minutos e nos modos de aplicação passiva, ativa vigorosa (fricção) e ativa suave (pincel). Após a análise em MEV, as fotomicrografias foram avaliadas um examinador calibrado e cego. A análise estatística (Teste de Kruskal-Wallis e Dunn), revelou que o gel de EDTA 24% da Biodinâmica promoveu inferior remoção "smear layer" em relação aos outros agentes testados. Não houve diferenças estatísticas para os tempos de aplicação. O modo de aplicação ativa suave (pincel) resultou em menor quantidade de "smear layer" residual. Conclui-se que as comerciais testadas do gel de EDTA 24% foram eficientes na remoção de "smear layer" e exposição de fibras colágenas, nos modos de aplicação ativa vigorosa (fricção) e ativa suave (pincel), independentes do tempo de aplicação. No entanto, a marca comercial Biodinâmica promoveu inferior remoção de "smear layer" e exposição de fibras colágenas em relação às outras marcas comerciais testadas. / Abstract: The aim of this study was to evaluate in vitro the conditioning efficacy with 24% EDTA gel from different trade marks times and application ways using scanning electron microscope. Extracted human teeth were submitted to cementum removal by means of diamond bur in high rotation speed, followed by scaling and root planning with Gracey 5-6 curette in order to further smear layer formation. The 225 samples were randomly assigned to 5 groups: I) control (sterile saline application); II) 24% EDTA (Santa Paula Pharmacy); III) 24% EDTA -T (Santa Paula Pharmacy); IV) 24% EDTA (Biora); V) 24% EDTA (Biodynamic). For each experimental group the application times were 1, 2 or 3 minutes. Substances were applied in 3 different ways: a) topical application (cotton pellets laid passively on the samples); b) vigorous friction (cotton pellets were scrubbed against samples surface); c) smooth friction (using a brush on dentinal surface). One calibrated examiner analyzed the micrographs. The statistical analysis (Kruskal Wallis Test and Dunn Test) showed that 24% EDTA (Biodynamic) proved to be less effective than others agents, there were no statistical differences between times of application. We conclude that smooth friction (using a brush on dentinal surface) of 24% gel efficiently removed the smear layer and exposed dentin collagen matrix in al times of application. The exception was the Biodynamic gel that did not achieve this result. / Doutor
4

Avaliação do aquecimento ósseo, da viabilidade celular imediata e da deformação de fresas de alta resistência após osteotomia para implantes em tíbias de coelhos /

Carvalho, Abrahão Cavalcante Gomes de Souza. January 2008 (has links)
Resumo: O propósito deste trabalho foi avaliar a influência da reutilização de fresas de alta resistência sobre o aquecimento ósseo, a viabilidade celular imediata e a deformação das fresas após osteotomia para implantes em tíbias de coelhos. Para isso, foram utilizados 12 coelhos machos brancos (Oryctolagus cunilicus, Nova Zelândia), que foram submetidos a 200 sequências de fresagens para implantes na cortical superior de suas tíbias. Foram estabelecidos 6 grupos (G1 a G6) que correspondiam ao número de osteotomias realizadas por cada fresa (0, 10, 20, 30, 40 e 50). Cada leito cirúrgico recebia a seguinte sequência de fresagem: fresa tipo lança e helicoidais de 2,0mm, 2,8mm, 3,0mm e 3.15mm. As áreas osteotomizadas foram coletadas para análise imunoistoquímica, as oscilações térmicas foram quantificadas e as fresas utilizadas receberam análise por microscopia eletrônica de varredura. Nos resultados, houve uma correlação alta entre a porcentagem de deformação e o número de reutilização de cada fresa (Coeficiente de Correlação de Pearson r = 0,984). Observou-se também que as fresas do tipo lança apresentaram maior deformação após o uso do que as fresas helicoidais (proporção de 2:1). Não houve correlação estatística significativa entre aumento da reutilização da fresa e aquecimento ósseo (p > 0,05). No entanto, observouse que a oscilação térmica durante a fresagem da lança é maior que as demais fresagens (proporção de 3:1). Na análise imunoistoquímica, observou-se um equilíbrio fisiológico da expressão das proteínas Osteoprotegerina e RANKL em todos os grupos, no entanto, houve maior expressão de todas as proteínas no Grupo 6. De acordo com a metodologia aplicada, foi possível concluir que as fresas avaliadas não causam aquecimento ósseo significativo em até 50 reutilizações, no entanto, causam maior trauma tecidual na 50ª fresagem... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The purpose of this study was evaluate the influence of high resistence drill reuse over bone heating, immediate bone-cell viability and drills wear after implant osteotomies in rabbit tibias. Therefore, 12 male white rabbits (Oryctolagus cunilicus, New Zealand) received 200 implant sequential osteotomies over the superior cortical of their tibia. Six groups were established (G1 to G6), according to the number of osteotomy of each drill (0, 10, 20, 30, 40 and 50). The implant sequence of drills was: spear drill, 2,0mm, 2.8mm, 3.0mm and 3.15mm helicoidal drills. The receptor-beds were collected to imunohistochemistry, the thermal changes were quantified and the drills received scanning electron microscopy analysis. In the results, a great correlation degree between drill wear and number of osteotomies was observed (Pearson's Correlation Coefficient r = 0,984). Another result was that spear drill have more deformation than helicoidal drills (2:1 proportion). The bone heating analysis concluded that there was no statistical siginificance between number of osteotomy and bone heating (p > 0,05). However, the thermal changes during spear drilling was greater than during helicoidal drillings (3:1 proportion). Imunohistochemistry results showed a physiological balance of Osteoprotegerin and RANKL immunolabeling in all groups, however there was a greater immunolabeling of all proteins in the last group. According to this metodology, the conclusion is that the tested drills do not caused significant bone heating after 50 reuses, however, they caused more tissue trauma at 50th osteotomy. So, the studied system must be reused for 40 times, and the spier drill must be substituted after 20 osteotomies. / Orientador: Luiz Antonio Salata / Coorientador: Osvaldo Magro Filho / Banca: Márcio de Moraes / Banca: Idelmo Rangel Garcia Júnior / Mestre
5

Avaliação "in vitro" da microinfiltração marginal e análise da fenda marginal cervical através da microscopia eletrônica de varredura, em restaurações de classe V de resina composta. Efeito dos sistemas adesivos e técnica de preparo cavitário /

Orbegoso Flores, Victor Humberto. January 2001 (has links)
Orientador: Marcelo Ferrarezi de Andrade / Banca: Marcos Ribeiro Moysés / Banca: Alberto Magno Gonçalves / Banca: Sillas Luiz Lordelo Duarte Júnior / Banca: Sizenando de Toledo Porto Neto / Resumo: O objetivo deste trabalho foi avaliar a formação de fendas marginais cervicais através da microscopia eletrônica de varredura, assim como, a microinfiltração marginal em preparos de classe V. foram utilizadas duas técnicas de preparo: P1 utilizando fresa carbide no 245 e P2 que utilizou o jato de ar abrasivo Mach 4.0 (80psi de pressão, 27 æm de tamanho de partícula). O tamanho das cavidades foi padronizado com 1,5 mm de profundidade, 2,0 mm de altura e 3,0 mm de largura. Os materiais utilizados foram: G1 -Optibond solo Plus, G2 - Prime & BondNT e G3 - Scotchbond Multiuso Plus (grupo controle), a resina composta Point 4 utilizada para restaurar as cavidades foi padronizada para todas as restaurações. Foram utilizados 42 dentes molares hígidos divididos em 3 grupos de 14 cada, utilizando a face vestibular e lingual sendo que os preparos mostraram a margem oclusal em esmalte e a margem cervical em cemento/dentina. Após as restaurações serem confeccionadas foram armazenadas em água deionizada durante 24 horas, para posteriormente realizar os procedimentos de acabamento e polimento, a seguir os dentes foram isolados com araldite e esmalte para unha e submetidos a testes de ciclagem térmico (400 ciclos)e imediatamente imersos numa solução de nitrato de prata, durante 2 horas, removidos, lavados e colocados numa solução fotoreveladora durante 16 horas. Nessas condições os dentes foram limpos e seccionados no sentido mésio/distal obtendo duas metades as quais por sua vez foram seccionadas no sentido vestíbulo lingual dividindo as restaurações pela metade. Assim, uma metade da restauração foi avaliada através da lupa esteroscópica para observar a microinfiltração e a outra metade preparada e metalizada para ser avaliada através da microscopia eletrônica de varredura. A análise estatística aplicada aos resultados permite concluir que... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: The aim of this study was to evaluate the formation of cervical gap with SEM, and the marginal microleakage in cavities class V. There were used two techniques for the preparations: P1 using a carbide # 245 and P2 using abrasive air Mach 4.0 (80 psi of preasure, 27nm measurement of the particle). The measurements of the cavities were standardized in 1.5mm of deepness, 2,0mm of highness and 3,0mm of lengthiness. The materials used were: G1 Optibond Solo Plus, G2 Prime & Bond NT and G3 Scotchbond Multiuso Plus (control group), it was used the composite Point 4 as the restorative material for all cavities. Forty-two healthy molars, divided in three groups of 14 each one, were used. Cavities were prepared in the buccal and lingual faces, its occlusal margin was in enamel and its cervical margin was in dentin/cement. After that finishing and polishing was made. Teeth were isolated with analdite and nail varnish and thermocycled (400 times). The preparations were dyed with "silver nitrate" for two hours. Preparations were stored in a photo developing solution for 16 hours. After that time teeth were cleaned and cut (buccal/lingual) Half of the preparation was observed in a stereoscopic microscope and the other half in a SEM. Results: 1.Preparations with abrasive air had a bigger gap; 2.Adhesive systems do not eliminate the formation of gaps; 3.Best results were found in the group prepared with bur and the adhesive Optibond Solo Plus, with a cervical gap 0,84nm, and in the other hand Scotchbond Multiuso Plus showed marginal gaps of 6,36nm; 4.In the occlusal margin Optibond Solo Plus had more microleakage tha Scotchbond Multiuso Plus and Prime & Bond NT.; 5. In the cervical margin, Optibond Solo Plus had good behavior controlling the marginal microleakage, compared with Scotchbond Multiuso Plus and Prime & Bond that had similar leakage between... (Complete abstract, click electronic address below). / Doutor

Page generated in 0.1687 seconds