• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 44
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 51
  • 51
  • 51
  • 51
  • 41
  • 41
  • 13
  • 11
  • 9
  • 9
  • 9
  • 9
  • 7
  • 7
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Análise do preparo, limpeza, desinfecção e obturação de canais radiculares de molares inferiores por diferentes protocolos e materiais /

João, Mariana Mena Barreto Pivoto January 2019 (has links)
Orientador: Juliane Maria Guerreiro Tanomaru / Resumo: Este estudo avaliou o preparo, limpeza e obturação de canais radiculares de molares inferiores por diferentes protocolos e materiais. Canais mesiais (n=48) de molares inferiores curvos (20°- 40°) foram preparados usando ProDesign Logic (PDL) até 25/.06 ou HyFlex EDM (HFEDM) 25/.08, e até PDL-40/.05 ou HFEDM-40/.04 na ampliação (Publicação 1). A irrigação final foi realizada com irrigação ultrassônica passiva-PUI ou easy clean-EC, hipoclorito de Sódio-NaOCl ou clorexidina-CLX ou água destilada (n=8): PUI/NaOCl2,5%; EC/NaOCl2,5%; EC/água destilada; PUI/CLX 2%; PUI/NaOCl 1%; PUI/NaOCl 2,5% (Publicação 2). A obturação foi realizada por condensação lateral-CL ou Termo Pack II e AHP (Publicação 3); cone único (CU) com nMTAP ou TFBC (Publicação 4). Escaneamentos (9 μm) foram realizados antes e após cada etapa experimental. Percentual de aumento volumétrico (%AV), debris (%D), redução de debris (%RD), superfície não instrumentada (%SNI), centralização, material obturador (%MO) e falhas (%F) foram analisados em toda a extensão do canal (total) e nos terços dos canais radiculares. Testes ANOVA e Tukey ou Kruskal-Wallis e Dunn, e T Pareado foram realizados (α = 0,05). HFEDM-25/.08 promoveu maior % AV. Após a dilatação, HFEDM apresentou maior volume (P < 0,05) e houve redução de %D e %SNI. Os sistemas produziram canais centralizados (Publicação 1). Houve diminuição do percentual e volume de debris acumulados após as técnicas e entre o PUI com diferentes soluções irrigantes. EC/NaOCl prop... (Resumo completo, clicar acesso eletrônico abaixo) / Doutor
32

Preparo e obturação de canais distais achatados de molares inferiores : análise por microtomografia computadorizada /

Santos Júnior, Airton Oliveira. January 2020 (has links)
Orientador: Juliane Maria Guerreiro Tanomaru / Resumo: Objetivo: Avaliar o preparo com instrumentos de níquel-titânio tratados termicamente em movimento rotatório ou reciprocante e a associação com inserto ultrassônico e capacidade de preenchimento pelas técnicas híbrida de Tagger ou cone único empregando o cimento Bio-C Sealer em canais radiculares achatados. Metodologia: Canais distais achatados de molares inferiores com diâmetro vestíbulo-lingual igual ou maior que 4 vezes o diâmetro mésio-distal foram preparados (n=12) por Reciproc Blue (RB) R40 em movimento reciprocante ou ProDesign Logic (PDL) 40.01 e 40.05 em movimento rotatório. Etapa complementar de instrumentação foi realizada com inserto ultrassônico Flatsonic nos dois grupos. Os canais foram obturados (n=12) pela técnica híbrida de Tagger ou cone único com o cimento Bio-C Sealer. Escaneamentos em resolução de 8,74 µm foram realizados em microtomografia computadorizada (micro-CT) antes e após todas as etapas experimentais. Percentual de aumento volumétrico, debris e superfície não instrumentada foram analisados para as etapas de preparo e percentual de falhas para obturação. Testes estatísticos ANOVA e Tukey, teste t pareado e não pareado foram realizados com nível de significância de 5%. Publicação 1 – Resultados: O percentual de aumento volumétrico, debris e superfície não instrumentada foi semelhante entre RB e PDL na extensão total do canal (P>0,05). PDL promoveu menor percentual de debris no terço cervical e menor percentual de aumento volumétrico no terço apical ... (Resumo completo, clicar acesso eletrônico abaixo) / Mestre
33

Análise por microtomografia computadorizada do preparo e obturação de canais radiculares achatados de segundos pré-molares superiores /

Tavares, Karina Ines Medina Carita. January 2020 (has links)
Orientador: Mario Tanomaru Filho / Resumo: Objetivo: Avaliar o preparo empregando dois sistemas rotatórios de níquel-titânio tratados termicamente e efeito do novo inserto ultrassônico e instrumento de menor diâmetro e a capacidade de preenchimento dos cimentos Bio-C Sealer ou AH Plus pela técnica de cone único em canais radiculares achatados de segundos pré-molares superiores. Metodologia: Canais radiculares achatados de segundos pré-molares superiores humanos com diâmetro vestíbulo-lingual igual ou maior que 4 vezes o diâmetro mésio-distal foram preparados com sistemas rotatórios(n=16): ProDesign Logic (PDL) 30.01 e 30.05 ou HyFlex EDM (HEDM) 10.05 e 25.08. Etapa do preparo complementar foi realizada com inserto ultrassônico Flatsonic (terço cervical e médio) e PDL 25.03 (terço apical) (FPDL) em ambos os grupos. Os canais radiculares foram obturados (n=16) com o cimento Bio-C Sealer ou AH Plus pela técnica de cone único. Escaneamentos em resolução de 8,74 µm foram realizados em microtomografia computadorizada (micro-CT) antes e após as etapas experimentais. Percentual de aumento volumétrico, debris e superfície não instrumentada foram analisados para as etapas de preparo e percentual de falhas para obturação. Os testes estatísticos específicos para o preparo e obturação foram realizados com nível de significância de 5%. Publicação 1 – Resultados: Não houve diferença estatística entre PDL e HEDM para o aumento de volume, debris e superfície não instrumentada no canal como um todo (P>0,05). PDL obteve maior percentual... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Objective: The aim of this study was to evaluate root canal preparation using two rotary nickel-titanium systems thermally treated and the effect of ultrasonic tip and small diameter instrument; and the filling capacity of sealers Bio-C Sealer and AH Plus by single cone technique in flattened root canals of maxillary second premolars. Methods: Flattened root canals of human maxillary second premolars with buccolingual diameter 4 or more times larger than the mesiodistal diameter were prepared with rotary systems (n=16): ProDesign Logic (PDL) 30.01 e 30.05 or HyFlex EDM (HEDM) 10.05 e 25.08. Complementary preparation step was performed with ultrasonic tip Flatsonic (cervical and middle thirds) and PDL 25.03 (apical third) (FPDL) in both groups. The root canals were filled (n=16) with Bio-C Sealer or AH Plus by single cone technique. Scanning in resolution of 8,74 µm were performed by microcomputed tomography (micro-CT) before and after the experimental steps. Percentage of increase in volume, debris and uninstrumented surface were analysed for the preparation steps and percentage of voids for obturation. The statistical tests specific to preparation and obturation analyses were performed with a significance level of 5%. Publication 1 - Results: There was no statistically difference between PDL and HEDM for volume increase, debris and uninstrumented surface, in entire canal (P>0,05). PDL showed higher debris in the middle and apical thirds than HEDM (P<0,05). The FPDL protocol ... (Complete abstract click electronic access below) / Mestre
34

Avaliação da adaptação marginal e interna de coroas de dissilicato de lítio confeccionadas pelo sistema CAD/CAM após escaneamento direto e indireto / Evaluation of the marginal and internal adaptation of lithium disilicate crowns made by the CAD / CAM system after direct and indirect scanning

Freitas, Bruna Neves de 15 December 2017 (has links)
O objetivo desse estudo foi avaliar a adaptação interna e marginal de coroas de dissilicato de lítio obtida por duas técnicas disponíveis pelo sistema CAD/CAM, o escaneamento direto e indireto. As análises foram realizadas por meio do microtomógrafo computadorizado (&microCT), microscópio confocal a laser (CL) e técnica da replica (TR), em dois momentos: antes e após a cristalização do material. O dente 14 de manequim foi preparado e duplicado em silicone, obtendo 20 réplicas em resina de poliuretano. Para a formação do Grupo 1 (IND/n=08), o manequim foi moldado com moldeira de estoque e silicone de adição com técnica de moldagem simultânea e modelagem com gesso pedra tipo III e IV, totalizando oito modelos em gesso. Os modelos foram escaneados com escâner indireto. Foram fresadas oito coroas de dissilicato de lítio. Para formação do Grupo 2 (DIR/n=08), o manequim foi escaneado com escâner direto. Oito imagens foram obtidas e enviadas ao laboratório pelo programa do sistema. Da mesma forma, foram fresadas oito coroas de dissilicato de lítio. As leituras da adaptação marginal das coroas foram realizadas com as mesmas adaptadas sobre a respectiva réplica em poliuretano, no &microCT, CL, e TR. As leituras da adaptação interna foram realizadas no &microCT e TR. As análises foram realizadas antes e após a cristalização das coroas. Os dados que apresentaram distribuição normal foram analisados por ANOVA dois fatores e os dados que não apresentaram distribuição normal foram analisados por teste U de Mann-Whitey para comparação entre os Grupos e pelo teste de Wilcoxon para comparação antes e após a cristalização. Em relação à adaptação axial, foi verificada diferença significante apenas para os Tempos (p=0,017), com menores valores após a cristalização. Para a adaptação interna não foi observada diferença entre os Grupos (p>0,05) ou Tempos estudados (p>0,05). Para a adaptação marginal vertical houve diferença para o Grupo IND, com maiores valores após a cristalização independente da metodologia de análise (&microCT - p=0,001; confocal - p=0,038). Já a medida marginal horizontal apresentou resultados divergentes de acordo com a metodologia utilizada. No &microCT, IND foi maior que DIR (p=0,003) e antes maior que após a cristalização (p<0,001). No confocal, IND menor que DIR após a cristalização (p=0,05), e para DIR, antes menor que após a cristalização (p=0,005). No volume total e volume marginal do espaço para cimentação houve diferença significante apenas para o DIR, com maiores valores após a cristalização (volume total - p=0,025; volume marginal - p=0,002). Pelos resultados obtidos pode-se concluir que há contração do material após a cristalização, resultando em maior desadaptação comprovado pelo aumento do volume total do espaço de cimentação em consequência da dificuldade de assentamento da coroa de dissilicato de lítio. / The objective of this study was to evaluate the internal and marginal adaptation of lithium desilicated crowns obtained by two alternative techniques to the CAD / CAM system, direct and indirect scanning. The analyzes were carried out by computerized microtomograph, laser confocal microscope and replica technique, in two moments: before and after the crystallization of the material. The manikin tooth 14 was prepared for total crown. Then it was duplicated, in silicone, and there were obtained 16 replicas in polyurethane resin. Two groups were formed from the impression of the manikin through the direct and indirect scanning, For the Group 1 (IND/n = 08), the manikin was molded with stock tray, with addition silicone, by the simultaneous molding technique and modeling performed with gypsum stone type III and IV, totaling eight molds and plaster models. The models were sent to the laboratory for scanning on the scanner indirect. Dissilicate crowns were made of lithium milled. For the Group 2 (DIR/n = 08), the dummy was scanned by scanner directly. The eight images obtained were sent directly to the laboratory by the system program. Likewise, milled lithium dissilicate crowns were made. The marginal adaptation of the crowns was performed with the same ones on the respective polyurethane tooth, in the computerized microtomograph (&microCT), confocal laser microscope (CL) and through the replica technique (TR). Internal adaptation readings were performed using a &microCT and TR. The analyses were made before and after the crystallization of the crowns. The data showed normal distribution were analyzed by two factors ANOVA and the data did not show normal distribution were analyzed for U Mann-Whitney test for comparison among groups and by the Wilcoxon test for comparison before and after the crystallization . In relation to the axial adaptation, significant difference was verified only for Times (p = 0.017), with lower values after crystallization. For the internal adaptation was not observed difference between groups (p > 0.05) or Times studied (p > 0.05). For the vertical marginal adaptation difference to the IND group, with higher values after the crystallization analysis methodology-independent (&microCT p = 0.001;-p = 0.038 confocal). Already the measure presented divergent results horizontal marginal according to the methodology used. In &microCT, IND was greater than DIR (p = 0.003) and greater than after the crystallization (p < 0.001). In confocal IND less than DIR after the crystallization (p = 0.05), and DIR, before less than after the crystallization (p = 0.005). In total volume and marginal volume of space for cementation significant difference only to the DIR, with higher values after the crystallization (total volume - p = 0.025; marginal volume - p = 0.002). The results obtained can be concluded that there is contraction of the material after the crystallization, resulting in higher leakage evidenced by the increase of the total volume of the cementing space as a result of the settling difficulty the dissilicate Crown.
35

Avaliação comparativa entre os reparos das lesões agudas e crônicas do manguito rotador em estudo experimental / Comparative evaluation between acute and chronic rotator cuff tear repairs in an experimental model

Cavinatto, Leonardo Muntada 03 February 2016 (has links)
Universidade de São Paulo, Faculdade de Medicina; 2015. Introdução: Diante de uma rotura traumática do manguito rotador, não há evidência direta que comprove que os reparos realizados precocemente são mais eficazes que aqueles realizados tardiamente. Para abordar essa questão, ensaios biomecânicos e de morfometria óssea foram realizados após roturas extensas do manguito rotador realizadas precocemente (lesões agudas) e tardiamente (lesões crônicas), mediante a utilização de um modelo experimental em ratos. Método: 30 ratos adultos da raça Wistar foram aleatoriamente divididos em três grupos (I, II e III) e submetidos à secção completa dos tendões do supraespinal e infraespinal nos ombros esquerdos. Após oito semanas, nos animais dos grupos I e II, os tendões rotos pertencentes aos ombros esquerdos foram cirurgicamente reparados, e os tendões equivalentes nos ombros direitos foram seccionados e imediatamente reparados. Quatro semanas após os reparos (para os ratos do grupo II) ou oito semanas após os reparos (para os ratos do grupo I), os animais foram submetidos à eutanásia. Os ratos do grupo III foram submetidos à eutanásia oito semanas após a cirurgia de secção tendínea sem que houvesse ocorrido o reparo dos tendões rotos. Os ombros direitos dos animais do grupo III permaneceram intactos e serviram como controles. Após a eutanásia, todos os ratos tiveram seus ombros dissecados e os espécimes foram encaminhados para a realização de testes biomecânicos e de microtomografia computadorizada. Resultados: Para todos os parâmetros biomecânicos analisados, foram encontradas interações significantes referentes aos fatores tempo de cicatrização e reparo, considerando os reparos precoces e tardios. Com relação ao tendão supraespinal para o período de oito semanas de cicatrização, a força máxima até a falha foi significantemente maior nos reparos precoces em comparação aos reparos tardios (31,81 ± 3,86N vs 19,36 ± 6,14N; p < 0,001), bem como a rigidez (17,22 ± 4,35N/mm vs 10,85 ± 4,25N/mm; p=0,034), a tensão máxima até a falha (4,49 ± 2,02N/mm2 vs 1,97 ± 0,61N/mm2; p < 0,001) e o módulo de elasticidade (13,72 ± 5,29N/mm2 vs 6,47 ± 2,42 N/mm2; p=0,033). Com relação ao tendão infraespinal com oito semanas de cicatrização, a força máxima até a falha foi significantemente maior nos reparos precoces em comparação aos reparos tardios (21,26 ± 3,94N vs 12,74 ± 2,87N; p=0,005), assim como a rigidez (12,86 ± 2,65N/mm vs 7,21 ± 3,30N/mm; p=0,014). O grupo com reparo tardio com oito semanas de cicatrização obteve resultados nos testes biomecânicos semelhantes aqueles obtidos nos testes do grupo com lesão sem reparo com oito semanas de cicatrização. A avaliação microtomográfica não apresentou diferenças significantes na microarquitetura óssea entre os reparos realizados precocemente e tardiamente. Conclusões: Os resultados desse estudo demonstram que as roturas extensas do manguito rotador reparadas precocemente produzem um tecido cicatricial na junção ósteo-tendínea com melhores propriedades biomecânicas que as roturas reparadas tardiamente. Porém, ao analisar a morfometria óssea da porção proximal do úmero, verificou-se que os efeitos são equivalentes, tanto para os reparos realizados tardiamente quanto para os reparos realizados precocemente / Introduction: In the event of a traumatic rotator cuff tear, there is no direct evidence that supports early over late surgical repair. To address this knowledge gap, biomechanical and bone morphometry outcomes were assessed following early (acute) and late (chronic) massive rotator cuff tear repairs in an experimental rat model. Methods: 30 adult Wistar rats were randomly divided into three groups (I, II and III), then subjected to combined supraspinatus and infraspinatus tendon tears of the left shoulder. Eight weeks following the injury, animals from groups I and II had the tendons of the injured shoulder surgically repaired. In addition, these animals were subjected to the same injury on the contralateral shoulder, which was immediately repaired. The rats were euthanized four weeks (group II) or eight weeks (group I) following the repairs. Group III was euthanized eight weeks following the injury, without surgical repair of the left shoulder, and the intact right shoulders of this group were used as controls. Tissues from all groups were harvested and subjected to biomechanical testing and bone morphometry analysis. Results: In all biomechanical parameters analyzed, a significant interaction was observed between healing and repair timing. For the supraspinatus tendon with eight weeks healing time, biomechanical properties were significant increased in the early repair group compared to the late repair group, including maximum load to failure (31,81 ± 3,86N vs 19,36 ± 6,14N; p < 0,001), stiffness (17,22 ± 4,35N/mm vs 10,85 ± 4,25N/mm; p=0,034), maximum stress to failure (4,49 ± 2,02N/mm2 vs 1,97 ± 0,61N/mm2; p < 0,001) and modulus of elasticity (13,72 ± 5,29N/mm2 vs 6,47 ± 2,42 N/mm2; p=0,033). For the infraspinatus tendon with eight weeks healing time, biomechanical properties were also significantly increased in the early repair group, including maximum load to failure (21,26 ± 3,94N vs 12,74 ± 2,87N; p=0,005) and stiffness (12,86 ± 2,65N/mm vs 7,21 ± 3,30N/mm; p=0,014). There were no significant differences between the late repair with eight weeks of healing time and the group without surgical repair for supraspinatus and infraspinatus tendons. Concerning bone morphometry of the humeral head, no significant differences were observed when comparing early and late repair groups. Conclusions: The results from this study indicate that early surgical repair of a massive rotator cuff tear leads to increased biomechanical properties of the tissue after healing. However, proximal humerus bone morphometry was unaffected by surgical repair timing
36

Avaliação microtomográfica e histomorfométrica comparativa de levantamento de seio maxilar em coelhos utilizando diferentes cerâmicas a base de fosfato de cálcio / Comparative microtomographic and histomorphometric evaluation of maxillary sinus augmentation using different calcium phosphate-based ceramics

Santos, Paula Sanches dos 25 May 2016 (has links)
A técnica de levantamento de seio maxilar (LSM) visa aumentar a altura óssea junto à superfície sinusal de maxila posterior atrófica utilizando diferentes materiais de preenchimento, para possibilitar a instalação de implantes dentários. Esses materiais de preenchimento podem variar quanto à origem e às propriedades físicoquímicas, resultando em diferentes respostas biológicas. O objetivo do atual trabalho foi avaliar a eficiência do Gen-Ox®inorg e GenPhos XP® na técnica de elevação do seio maxilar em comparação ao Bio-Oss®. Em 24 coelhos foi realizado o levantamento bilateral dos seios maxilares (SMs) utilizando 200 mm3 de material de preenchimento por seio, conforme os grupos experimentais Bio-Oss (6SMs/período), Gen-Ox (5SMs/período) e GenPhos (5SMs/período), e a janela óssea de acesso foi recoberta com uma membrana reabsorvível. Os animais de cada grupo foram eutanasiados aos 15, 30 e 60 dias e a região dos SMs foi coletada e fixada em formalina a 10% tamponada. As peças foram submetidas à análise microtomográfica para determinação do volume total do SM elevado e em seguida ao processamento histológico, sendo cortes coronais dos SMs obtidos e avaliados morfometricamente pelo método de volumetria de pontos. Todos os três materiais apresentaram excelente biocompatibilidade e promoveram a manutenção do volume do seio preenchido ao longo do tempo, sendo em média de 214,1 mm3. Em todos os grupos a formação óssea ocorreu em íntimo contato com as partículas de material. Ao término de 60 dias, o tecido ósseo formado mostrava-se maduro e preenchia parcialmente os espaços entre as partículas. A forma e tamanho das partículas de Gen-Ox gerou maior espaço entre as partículas que pode ter levado a formação de maior volume de tecido ósseo e de tecido conjuntivo (53,0 ± 10,1 mm3 e 74,1 ± 21,5 mm3) comparado ao Bio-Oss (43,7 ± 11,6 mm3 e 61,2 ± 23,3 mm3) e GenPhos (47,5 ± 10,4 mm3 e 58,5 ± 25,7 mm3). Baseado na estabilidade do volume sinusal elevado, na capacidade osteocondutora e na formação e maturidade óssea ao longo do tempo promovidos pelo Gen-Ox®inorg e GenPhos®, comparável ao do Bio-Oss®, conclui-se que esses dois biomateriais significam uma alternativa segura na técnica de LSM. / Maxillary sinus augmentation (MSA) for implant placement using bone graft or bone substitutes is a common procedure to increase the bone volume in the atrophic posterior part of the maxilla. Various bone substitutes have been used in sinus floor elevation procedures. Nonetheless, the biological performance of bone substitutes may vary according to origin, physical and chemical properties. The goal of this study was to evaluate the efficiency of both Gen-Ox®inorg and GenPhos XP® in maxillary sinus augmentation technique compared to Bio-Oss®. In 24 rabbits, it was conducted a bilateral lifting of the maxillary sinuses (MSs) using 200 mm3 of filling material for sinus in accordance with the experimental groups Bio-Oss (6SMs/period), Gen-Ox (5MSs/period) and GenPhos (5MSs/period). The sinus access window was covered with a resorbable membrane. The animals of each group were euthanized at 15, 30 and 60 days and the MSs were collected and fixed in 10% buffered formalin. The samples were submitted to microtomographic analysis to calculate the MS augmentation volume. Histological coronal sections of MS augmentation were used for morphological analysis and determination of volume density of each structure by point counting volumetry method. All three materials had excellent biocompatibility and promoted maintenance of the MS augmentation volume over time, averaging 214.1 mm3. In all groups the bone formation occurred in close contact with the material particles. At the end of 60 days, the bone tissue formed was mature and it partially filled the spaces between the particles. The shape and size of Gen-Ox particles generated greater space between the particles that may have led to a higher formation of bone volume and connective tissue (53.0 ± 10.1 mm3 and 74.1 ± 21.5 mm3) than Bio-Oss (43.7 ± 11.6 mm3 and 61.2 ± 23.3 mm3) and GenPhos (47.5 ± 10.4 mm3 and 58.5 ± 25.7 mm3). Based on the stability of the MS volume, the osteoconductive capacity and the bone formation and maturation over time promoted by Gen-Ox®inorg and GenPhos®, and comparable to Bio-Oss®, it is concluded that these two biomaterials may be a safe alternative in MSA technique.
37

Pre-clinical and clinical studies of a novel porous biphasic calcium phosphate ceramic as alternative to repair bone defects / Estudos pré-clínico e clínico de uma nova cerâmica bifásica porosa de fosfato de cálcio como uma alternativa para o reparo de defeitos ósseos

Machado, Ricardo Quirico Pinheiro 13 February 2019 (has links)
Objectives: We compared a novel porous biphasic calcium phosphate (pBCP) containing 70% HA and 30% -TCP with autogenous bone (AB) regarding bone formation, graft granular size influence (0.7, 1.0 or 1.5 mm), physicochemical properties, and volumetric changes of the total grafted area as well its components (newly formed bone, graft particle stability and soft tissue). Materials and methods: Article 1 used a critical size defect in rats. Analyzes included XRD (X-ray diffraction), SEM (scanning electron microscope) and EDS (Energy-dispersive X-ray spectroscopy) in vitro and then histomorphometry of biopsies collected from rat skull. Article 2 used a bilateral MSFA by lateral wall surgery in 12 patients in a split-mouth design. Analyses of three-dimensional (3D) cone beam computed tomography (CBCT) scans at different periods (T0, T1 and T2), and of micro-CT scans and histological slides of graft core biopsies were performed. Results: In the preclinical approach, similar physicochemical characteristics among pBCPs with different granular sizes were found. Besides, osteopromotion regarding pBCP granular sizes of 0.7 and 1.0 were higher than AB. In the clinical approach, pCBP was similar to AB. However, in both approaches, the volume of the total grafted area and particles within the grafted area were more reduced for AB (45% and 37%, respectively, in article 1 and 31% and 33%, respectively, in Article 2). For pBCP these volumetric changes did not occur, except for 1.5 mm size group in the preclinical approach, which showed a significant reduction in the last period (24 weeks). Conclusion: pBCP70:30 physicochemical characteristics, such as slow resorption, creates a favorable microenvironment for bone formation that is directly influenced by the granule size. pBCP70:30 promotes greater preservation of the grafted volume than AB, thus being a good alternative for MSFA and bone regeneration procedures. / Objetivos: Nós comparamos um novo fosfato de cálcio bifásico poroso (pBCP contendo 70% HA e 30% -TCP com o osso autógeno (AB) quanto à formação óssea, influência do tamanho granular do enxerto (0,7, 1,0 ou 1,5 mm), propriedades físico-químicas e alterações volumétricas da área total enxertada, bem como seus componentes (osso recém-formado, estabilidade das partículas do enxerto e tecido mole). MATERIAIS E MÉTODOS: O artigo 1 usou um defeito de tamanho crítico em ratos. As análises in vitro incluíram XRD (difração de raios X), SEM (microscopia eletrônica de varredura) e EDS (espectroscopia de dispersão de energia por raios X) e depois análise histomorfometria de biópsias coletadas da calvária de ratos. O artigo 2 envolveu utilização do material para elevação bilateral de seio maxilar em 12 pacientes, em um desenho split-mouth. Análise de tomografia computadorizada tridimensional (3D) de feixe cônico (TCFC) em diferentes períodos (T0, T1 e T2), micro-CT scans e lâminas histológicas de biópsias do enxerto foram realizadas. Resultados: Na abordagem pré-clínica, foram encontradas características físico-químicas semelhantes entre os pBCPs com diferentes tamanhos granulares. Em adição, a osteopromoção, para os tamanhos granulares do pBCP de 0,7 e 1,0 mm foram maiores que para o AB. Na abordagem clínica, o pBCP foi semelhante ao AB. No entanto, em ambas as abordagens, o volume total da área enxertada e o volume das partículas dentro da área enxertada foram menores para o AB (45% e 37% respectivamente no artigo 1 e 31% e 33% respectivamente no Artigo 2). Para o pBCP mudanças volumétricas não ocorreram, exceto para o grupo tamanho 1,5 mm na abordagem pré-clínica, que mostrou uma redução significativa no último período (24 semanas). Conclusão: As características físico-químicas do pBCP, como a lenta reabsorção, criam um microambiente favorável para a formação óssea e isso é diretamente influenciado pelo tamanho dos grânulos. O pBCP70: 30 promove maior preservação do volume enxertado em comparação ao AB, sendo uma boa alternativa para o aumento do seio maxilar e para os procedimentos de regeneração óssea.
38

ESTUDO DO COMPORTAMENTO DE RESINAS BULK FILL EM RESTAURAÇÕES CLASSE I POR MEIO DE MICROTOMOGRAFIA COMPUTADORIZADA E MICROTRAÇÃO / STUDY OF BULK FILL RESIN BEHAVIOR IN CLASS I RESTRICTIONS BY COMPUTERIZED MICROTOMOGRAPHY AND MICROTRATION

ALMEIDA JUNIOR, Lauber Jose dos Santos 12 June 2017 (has links)
Submitted by Daniella Santos (daniella.santos@ufma.br) on 2017-06-20T14:13:09Z No. of bitstreams: 1 Lauber Jose.pdf: 935752 bytes, checksum: 4853ee9a573d926513f92f2560f03c9a (MD5) / Made available in DSpace on 2017-06-20T14:13:10Z (GMT). No. of bitstreams: 1 Lauber Jose.pdf: 935752 bytes, checksum: 4853ee9a573d926513f92f2560f03c9a (MD5) Previous issue date: 2017-06-12 / FAPEMA / The polymerization shrinkage (PS) and the detrimental effects have been the focus of studies with the aim of improving the performance of composite resins. The simplicity of technique due to the possibility of single fill in large quantities have allowed bulk fill composite resins (BFC) to be indicated to minimize this shrinkage. This thesis, divided in two chapters, aimed to evaluate the behavior of bulk fill composite resins in class I restorations by mans computerized microtomography (μCT) and microtensile bond strength (μTBS). Chapter I evaluated the PS and μTBS in BFC and conventional class I restorations composite resins, and the correlation between these factors. Class I cavities (4 x 5 x 4 mm), (factor-C = 4.2), were created in human third molars that were free of caries, which were randomized and divided into 4 groups (n = 6): Z350 XT(+): incremental insertion (II) and manual fill (MF); Z350 XT(-): single insertion (SI) and MF; TBF (Tetric N-Ceram Bulk Fill: SI and MF); and SFU [SonicFill: SI and ultrasonic fill (UF) ]. The teeth were scanned and analyzed in μCT at two times: T0- after the filling of the cavity with composite resins and T1- after the polymerization for PS. After 1 week, the teeth were sectioned crosswise in the buccolingual and mesiodistal directions to obtain specimens with approximately 1 mm² thickness and fixed to universal test machine device to perform μTBS. The data showed a statistically significant difference for PS between the groups Z350 XT(+) e Z350 XT(-), and between SF e Z350 XT(-) (Kruskal-Wallis and Dunn, p<0.05). he μTBS was higher for Z350 XT (+) than the other groups (p <0.05) and there was no correlation between PS and μTBS (p> 0.05). It was concluded that the BFC type present a PS similar to that of the conventional nanoparticulate composite resin inserted using the incremental technique. The bond strength was higher for the composite resin incrementally inserted, which presented a lower number of pre-test failures when compared to bulk fill composites. No correlation was observed between the PS and bond strength when bulk fill and conventional composites were used. Chapter II evaluated the volume of polymerization shrinkage (VS), gap (VG) and void (VV) using μCT in BFC and conventional class I restorations, and their correlations. Class I cavities (4 x 5 x 4 mm), factor-C = 4.2, were created in human third molars that were free of caries, which were randomized and divided into 5 groups (n = 6): Z350 XT(+) (II/MF); Z350 XT(-) (SI/MF); TBF (SI/MF); SFM [ (SonicFill: SI and MF) ] and SFU (SI/UF). The teeth were scanned and analyzed in μCT at two times: T0- after the filling of the cavity with composite resins and T1- after the polymerization for VG and VV, and for VS (T1-T0). After 1 week, the teeth were sectioned crosswise in the buccolingual and mesiodistal directions to obtain specimens with approximately 1 mm² thickness and fixed in a universal testing machine to perform μTBS. Kruskal-Wallis and Dunn tests showed statistically significant difference in VS for groups Z350 XT(+) and Z350 XT (-), and between SFU and Z350 XT(-), and difference between VV for Z350 XT(+) and BFC (p <0.05). There was no difference in VG between the conventional and BFC (p>0.05). There is a positive correlation between VS versus VG and between VS versus VV (Spearman, p <0.05). It was concluded that BFCs of both sonic and manual insertion showed polymerization shrinkage and gap formation similar to the incrementally inserted nanoparticulate conventional resin. There is a positive correlation between polymerization shrinkage and final gap formation, as well as between polymerization shrinkage and void in composite resins. The final gap was formed mainly by the initial gap generated during the insertion/filling of the composite in the cavity and not to the polymerization shrinkage. / A contração de polimerização (CP) e seus efeitos prejudiciais vêm sendo o foco de estudos com o intuito de melhorar o desempenho das resinas compostas. A simplicidade da técnica devido a possibilidade de preenchimento único em grande quantidade tem permitido que resinas bulk fill (RBF) sejam indicadas para minimizar essa contração. Esta tese, dividida em dois capítulos, teve por objetivo avaliar o comportamento de resinas bulk fill em restaurações classe I por meio de microtomografia computadorizada (μCT) e resistência de união por microtração (μTBS). O capítulo I avaliou a CP por μCT e a μTBS em restaurações classe I de RBF e convencional, e a correlação entre esses fatores. Cavidades classe I (4x5x4 mm), (fator-C=4,2) foram realizadas em terceiros molares livres de cárie, que foram randomizados e divididos em 4 grupos (n=6): Z350 XT(+): inserção incremental(II) e preenchimento manual (PM); Z350 XT(-): inserção única (IU) e PM; TBF (Tetric N Ceram Bulk Fill: IU e PM); e SFU [SonicFill: IU e preenchimento ultrassônico (PU) ]. Os dentes foram escaneados e analisados em μCT em dois tempos: T0- após o preenchimento da cavidade com resinas compostas e T1- depois da polimerização para CP. Após 1 semana os dentes foram seccionados transversalmente no sentido vestíbulo-lingual e mesio-distal para obtenção de espécimes com aproximadamente 1mm² de espessura, e fixados em dispositivo para máquina de ensaio universal para realizar μTBS. Os dados demonstraram diferença estatisticamente significante para a CP entre os grupos Z350 XT(+) e Z350 XT(-) e entre SFU e Z350 XT(-) (Kruskal-Wallis e Dunn, p<0.05). A μTBS foi maior para Z350 XT(+) em relação aos demais grupos (p<0.05) e não houve correlação entre CP e a μTBS (p>0.05). Concluiu-se que RBF apresentaram CP semelhante à resina convencional nanoparticulada inserida de forma incremental. A resistência de união foi maior para a resina convencional inserida pela técnica incremental que apresentou menor falhas pré-teste, quando comparada às RBF. Não foi observada correlação entre a CP e a resistência de união quando utilizadas RBF e convencionais. O capítulo II avaliou o volume de contração de polimerização (VC), gap (VG) e poro (VP) usando μCT em restaurações classe I de RBF e convencional, e suas correlações. Cavidades classe I (4x5x4 mm), fator-C=4,2, foram realizadas em terceiros molares humanos livres de cárie que foram randomizados e divididos em 5 grupos (n=6): Z350 XT(+) (II/PM); Z350 XT (-) (IU/PM); TBF (IU/PM); SFM [ (SonicFill (IU/PM) ] e SFU (IU/PU). Os dentes foram escaneados e analisados em μCT em dois tempos: T0- após o preenchimento da cavidade com resinas compostas e T1- depois da polimerização para VG e VP, e VC (T1-T0). Após 1 semana os dentes foram seccionados transversalmente no sentido vestíbulo-lingual e mesio-distal para obtenção de espécimes com aproximadamente 1mm² de espessura, e fixados em máquina de ensaio universal para realizar μTBS. Os testes de Kruskal-Wallis e Dunn, demonstraram diferença estatisticamente significante no VC em μCT para os grupos Z350 XT(+) e Z350 XT (-) e entre SFU e Z350 XT(-), e diferença entre o VP para Z350 XT(+) e as RBF (p<0.05). Não houve diferença para o VG entre as RBF e convencional (p>0.05). Houve correlação positiva entre a VC versus VG e entre VC versus VP (Spearman, p<0.05). Concluiu-se que as RBF tanto de inserção sônica quanto manual mostraram contração de polimerização e formação de gap semelhante à resina convencional nanoparticulada inserida de forma incremental. Há uma correlação positiva entre a contração de polimerização e a formação de gap final, assim como entre a contração de polimerização e poro nas resinas compostas. O gap final foi formado principalmente pelo gap inicial gerado durante a inserção/preenchimento da resina na cavidade e não à contração de polimerização.
39

Biomateriais multifuncionais aplicados em reparo ósseo na odontologia /

Barud, Hélida Gomes de Oliveira. January 2017 (has links)
Orientador: Osmir Batista de Oliveira Junior / Abstract: A regeneração óssea caracteriza-se por ser um processo fisiológico complexo que envolve a participação coordenada entre angiogênese e osteogênese. Envolve um processo de múltiplas etapas que inclui migração, proliferação e diferenciação de vários tipos de células, como células endoteliais, fibroblastos, osteoblastos e osteoclastos. Sabe-se que os biomateriais sintéticos têm demonstrado ser uma excelente alternativa ao reparo ósseo. Assim, o objetivo deste estudo foi avaliar o efeito do Biosilicato de sódio (BS) e dos compósitos 3D de 30% de hidroxiapatita e ácido poliláctico (3D 30% HA / PLA) e 30% hidroxiapatita e ácido poli (ácido láctico-co-glicólico) (30% HA / PLGA), e em defeitos críticos na calvária de ratos. Cento e vinte ratos machos de 90 dias com 350g de massa corporal em média foram aleatoriamente divididos em grupos de acordo com materiais de enxerto e tempo de análise, apresentando 6 animais em cada um. Os defeitos de tamanho crítico foram criados empregando-se uma trefina de 8 mm de diâmetro interno e preenchidos com os materiais mencionados ou apenas o coágulo sanguíneo como controle. Após 14 (T1), 30 (T2), 60 (T3), 90 (T4) e 120 dias (T5) dias do procedimento cirúrgico, a regeneração óssea foi avaliada por radiografia, microtomografia computadorizada (μ-CT) e histologia. A avaliação macroscópica mostrou biocompatibilidade em torno da área de interesse entre os biomateriais e ossos adjacentes. As imagens de μ-CT e de raios-x revelaram uma considerável formação ... (Complete abstract click electronic access below) / Resumo: The process of bone regeneration requires a coordinated coupling between osteogenesis and angiogenesis involveing a multistep process that includes migration, proliferation, and differentiation of several types of cells such as endothelial, fibroblasts, osteoblasts and osteoclasts. It is known that synthetic biomaterials have been proven to be an excellent alternative to bone repair. Thus, the aim of this study is to evaluate the effect of calcium and sodium Biosilicate (BS), a 3D scaffold of hydroxyapatite and polylactic acid (30% HA / PLA) and a hydroxyapatite and poly (lactic-co-glycolic acid) (30% HA / PLGA) composites in critical-sized calvarial defects. One hundred and twenty 90 days old male rats with 350g of body mass on average were randomly divided into groups (n = 6) according to graft materials and analysis time. Critical-size defects were created by means of a 8 mm inner diameter trephine bur and were filled with a 3D 30% HA/PLGA scaffold, 30% HA/PLA, BS or blood clot as control. After 15 (T1), 30 (T2), 60 (T3), 90 (T4) and 120 (T5) days of the cirurgical procedure, bone regeneration was evaluated by histology, x-ray and micro-computed tomography (µ-CT). Macroscopic evaluation showed no significant inflamation around the interest area. µ-CT results indicates that 30% HA/PLA and 3D 30% HA/PLGA composites were not fully degraded and images revealed considerable bone formation in 90 days and 120 days in relation to these materials. On the other hand, BS presented a ... (Resumo completo, clicar acesso eletrônico abaixo) / Doutor
40

Efeito do preparo rotatório e reciprocante no canal e dentina radicular e na qualidade da obturação, usando cimentos a base de silicato de cálcio /

Mendes, Camila Almeida Nascimento. January 2017 (has links)
Orientador: Juliane Maria Guerreiro Tanomaru / Resumo: Os instrumentos de níquel-titânio usados durante o preparo dos canais radiculares podem sofrer diferentes processos de tratamento na liga durante a fabricação. Sistemas de instrumentação mecanizada apresentam formatos individuais dos instrumentos, sendo sugeridas diversas cinemáticas de atuação durante a ação de corte da dentina. Os sistemas de único instrumento usados em cinemática reciprocante e novos instrumentos com tratamento térmico das ligas devem ser estudados quanto ao efeito sobre o preparo do canal e dentina radicular. A anatomia do canal, as técnicas obturadoras e o emprego de diferentes materiais podem influenciar na qualidade da obturação. O objetivo do estudo foi avaliar o preparo de canais achatados de incisivos inferiores e canais mesiais de molares inferiores com instrumento rotatório e/ou reciprocante, bem como a qualidade da obturação usando diferentes técnicas ou cimento de silicato de cálcio. Noventa incisivos inferiores apresentando canais achatados foram preparados com sistema Mtwo em rotação contínua (Mtwo rot) até 40/.06; Mtwo 40/.06 instrumento único em cinemática reciprocante horária (Mtwo rec) e Reciproc (R40) (n=30). Os dentes foram escaneados por microtomografia computadorizada (Micro-CT) antes e após o preparo. Os dados foram expressos em porcentagem do aumento de volume do canal (%V), redução da espessura de dentina (%DTR), área de superfície não instrumentada (%S) e debris remanescente (%D). O tempo necessário para o preparo foi anotado. Cana... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The nickel-titanium instruments used during the preparation of root canals can present different treatment processes in alloy during manufacturing. Mechanized instrumentation systems present instruments with individual formats, being suggested various kinematics during the action on the dentin. Single instrument systems used in reciprocating kinematics and the new instruments with thermal treatment of alloys should be studied as to the effect on the preparation of the root canal and dentin. The anatomy of the root canal, the filling techniques and the use of different materials can influence in the quality of filling. The objective of this study was to evaluate the flattened root canal preparation of mandibular incisors and mesial root canals mandibular molars using rotatory and/or reciprocating instruments, as well the quality of root canal obturation using different techniques or calcium silicate sealer. Ninety mandibular incisors presenting flattened canals were prepared using Mtwo system in continuous rotation (Mtwo rot) up to 40/.06; Mtwo 40/.06 single instrument in reciprocating motion (Mtwo rec) and Reciproc (R40) (n = 30). The teeth were scanned by computed microtomography (Micro-CT) before and after the preparation. Data were expressed as a percentage of the increase in volume of root canal (% V), reduction of the thickness dentin (% DTR), uninstrumented surface area (% S) and remaining debris (% D). The time required for the preparation was noted. Mesial root canals... (Complete abstract click electronic access below) / Doutor

Page generated in 0.0803 seconds