• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • Tagged with
  • 6
  • 6
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação dos estudantes no uso de um transferente modificado por meio de escala visual analógica

Morsch, Carolina Schäffer January 2015 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2015. / Made available in DSpace on 2015-10-06T04:07:52Z (GMT). No. of bitstreams: 1 334678.pdf: 4159754 bytes, checksum: 549463002fbd9d77fc8d2785013f0742 (MD5) Previous issue date: 2015 / Declaração do problema. Para um novo produto ser incorporado no mercado este deve ser testado pelo seu público alvo. A percepção dos profissionais quanto ao produto deve ser analisada. Objetivo. O objetivo deste trabalho foi avaliar a percepção de estudantes de especialização em Implantodontia e em Prótese Dentária ao realizar moldagens de transferência de implantes dentários com transferentes quadrado convencional e modificado quanto ao nível de dificuldade, preferência, eficiência e uso futuro. Materiais e métodos. Participantes deste estudo: 25 alunos de cursos nacionais de especialização. Cada aluno realizou em um paciente uma moldagem de transferência da posição de implante de plataforma hexagonal externa com transferente quadrado convencional, criando retenções adicionais com resina acrílica e uma com transferente modificado do mesmo implante. Foi utilizado questionário de escala visual analógica para avaliar a percepção do estudante quanto ao nível de dificuldade, preferência, eficiência do transferente modificado para moldeira aberta e se este substituirá o convencional no uso futuro. As respostas foram convertidas em formato numérico, variando de 0 a 100 para análise estatística com o teste de Wilcoxon. Resultados. Os estudantes classificaram um nível de dificuldade de 43,74 (±23,31) para impressões realizadas com transferente convencional e de 20,79 (±23,66) com o modificado. Dos 25 estudantes, 88% preferiram o modificado, 92% classificaram o modificado como mais eficiente e 80% acham que o novo transferente substituirá o convencional. Todas as avaliações foram estatisticamente significativas(p<.05). Conclusões. Segundo a percepção dos estudantes, o transferente modificado foi mais eficiente e fácil de operar. Preferiram o novo transferente e acreditam que este será mais utilizado no futuro. IMPLICAÇÕES CLÍNICAS. Ao introduzir-se um transferente quadrado modificado para moldagem de transferência de implantes, estudantes de especialização avaliaram que a técnica com o transferente modificado substituirá a convencional.<br> / Abstract : Statement of problem. To a new product be incorporated by the market must be tested by the relevant public. The professionals perception with regard to the product must be analysed. Purpose. To evaluate the perception of specialization students when performing implant impressions with conventional and modified square transfers on the level of difficulty, preference, efficiency and future use. Material and methods. Study participants: 25 specialization students. Each student made, in a patient, external hexagon connection implant impressions, one with conventional square transfer creating retentions with acrylic resin and another with a modified square transfer of the same implant. A visual analog scale questionnaire was used to asses the student perception of dificulty, preference, modified open tray transfer efficiency and if the the modified transfer will replace the conventional on the future use. Responses were converted to numeric format, ranging from 0 to 100 for statistical analysis with Wilcoxon Test. Results. The students scored a mean difficulty level of 43,74 (±23,31) for the impression with the conventional transfer and 20,79 (±23,66) with the modified. From the 25 students, 88% preferred the modified, 92% felt the modified most effective, and 80% felt that the new transfer will replace the conventional. All evaluations were statistically significant (p<.05). Conclusions. According to the students perception, the modified transfer was more efficient and easy to operate. They preferred the modified transfer and believe that this one will be more employed in the future. CLINICAL IMPLICATIONS When introducing a modified transfer to implant impressions, specialist students valued the modified technique will replace the one with the conventional transfer.
2

Estudo das alterações de polimerização das siliconas de adição, decorrentes de seu contato com soluções adstringentes e fios de afastamento gengival manipulados com luvas de látex

Machado, Carlos Eduardo Palhares January 2007 (has links)
Dissertação (Mestrado em Ciencias da Saúde)—Universidade de Brasília, Programa de Pós-graduação em Ciências da Saúde. / Texto parcialmente liberado pelo autor. Conteúdo disponível: Resumo. / Submitted by Jaqueline Ferreira de Souza (jaquefs.braz@gmail.com) on 2013-02-26T15:07:07Z No. of bitstreams: 1 2007_CarlosEduardoPalharesMachado_RESUMO.PDF: 30664 bytes, checksum: 2a50e2a1f27759a43ed09206eea050bd (MD5) / Approved for entry into archive by Jaqueline Ferreira de Souza(jaquefs.braz@gmail.com) on 2013-02-26T15:07:21Z (GMT) No. of bitstreams: 1 2007_CarlosEduardoPalharesMachado_RESUMO.PDF: 30664 bytes, checksum: 2a50e2a1f27759a43ed09206eea050bd (MD5) / Made available in DSpace on 2013-02-26T15:07:21Z (GMT). No. of bitstreams: 1 2007_CarlosEduardoPalharesMachado_RESUMO.PDF: 30664 bytes, checksum: 2a50e2a1f27759a43ed09206eea050bd (MD5) / O presente trabalho teve por finalidade estudar, in vitro, as possíveis interações entre três marcas de siliconas de adição (Adsil, Vigodent, Brasil; Express, 3M, EUA; Aquasil Ultra, Dentsply, EUA) e luvas de látex (Satari, Brasil; Embramac, Brasil), luvas de vinil (Volk, Brasil), soluções adstringentes à base de sulfato férrico (Stat-Gel, Pascal, EUA), sulfato de alumínio (GelCord, Pascal, EUA) e cloreto de alumínio (Hemostop, Dentsply, Brasil), bem como fios de afastamento gengival previamente manipulados com luvas de látex (contaminação indireta), com vistas a determinar se estas substâncias e compostos seriam capazes de inibir ou alterar o processo de presa dos materiais polivinílicos. A metodologia adotada contou com a utilização de um aparelho que permitiu a análise simultânea dos materiais questionados e grupos controle, baseando-se na análise superficial dos materiais de moldagem e superfícies moldadas. Os resultados do estudo indicaram que: (1) o látex promoveu inibição em todas as marcas de silicona; (2) o contato direto entre a luva de vinil da marca Volk e as siliconas de adição da marca Adsil e Express resultou no retardo de polimerização destes materiais; (3) o contato direto entre a silicona de adição da marca Aquasil Ultra e as amostras da luva de vinil não resultou em inibição ou retardo de polimerização; (4) as soluções de Sulfato Férrico, Sulfato de Alumínio e Cloreto de Alumínio não promoveram inibição ou retardo de polimerização em nenhuma das marcas de siliconas de adição testadas; (5) A utilização de fios de afastamento gengival manipulados com luvas de látex, independente do tipo de adstringente associado, não promoveu inibição ou retardo de polimerização em nenhuma das marcas de siliconas de adição testadas.
3

Avaliação in vitro da adaptação marginal e interna de coroas de cerâmica e resina composta fabricadas com o sistema CAD/CAM utilizando duas câmeras intraorais de moldagem digital

Silveira, Alessandra Cristina de Paula 04 December 2015 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Ciências da Saúde, Programa de Pós-Graduação em Ciências da Saúde, 2015. / Submitted by Fernanda Percia França (fernandafranca@bce.unb.br) on 2016-06-15T17:46:36Z No. of bitstreams: 1 2015_AlessandraCristinadePaulaSilveira.pdf: 50764459 bytes, checksum: c573778d4cd0c33649569da7b6770459 (MD5) / Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2016-07-21T16:48:27Z (GMT) No. of bitstreams: 1 2015_AlessandraCristinadePaulaSilveira.pdf: 50764459 bytes, checksum: c573778d4cd0c33649569da7b6770459 (MD5) / Made available in DSpace on 2016-07-21T16:48:27Z (GMT). No. of bitstreams: 1 2015_AlessandraCristinadePaulaSilveira.pdf: 50764459 bytes, checksum: c573778d4cd0c33649569da7b6770459 (MD5) / O objetivo deste estudo in vitro foi avaliara adaptação marginal e interna de coroas totais obtidas a partir de blocos pré-fabricados de Lava Ultimate 3M ESPE (resina nanocerâmica) e IPS e.max CAD IvoclarVivadent(cerâmica de dissilicato de lítio) com dois tipos de moldagem digital, câmera intraoralBluecam e câmera intraoralOmnicam, por meio do microtomógrafo. Métodos: Dez terceiros molares humanos hígidos foram preparados para receber coroas totais. Para cada molar preparado, foram realizadas duas impressões ópticas, uma com a Bluecam e a outra com a Omnicam, onde foram fresadas quatro diferentes coroas. Os quatro grupos formados foram: Grupo1 (Lava Ultimate+Bluecam); Grupo 2 (Emax+Bluecam); Grupo 3 (Lava Ultimate+Omnicam); Grupo 4 (Emax+Omnicam). A avaliação da adaptação marginal e interna sem ajuste foi realizada com a simulação da cimentação de cada coroa em seu respectivo dente com um silicone leve. O conjunto foi levado a um microtomógrafo e a discrepância marginal foi avaliada bidimensional e tridimensional para as variáveis gap axial (GA), gap oclusal (GO), gap marginal (GM), desadaptação marginal absoluta (DMA) e desadaptação entre a coroa e preparo (DCP). A significância estatística foi avaliada com o teste Shapiro-Wilk e ANOVA (p <0.05). O teste de Tukey como post hoc associado com a correção de Bonferroni, e Kruskal Wallis (p<0.05) com Mann-Whitney, como post hoc associado com a correção de Bonferroni para ajuste de múltiplas comparações.Resultados: As câmeras Bluecam e Omnicam, não foram observadas diferenças significativas para as variáveis GA (p= 0.2325) e GO ( p= 0.1400). Para Lava Ultimate e Emax-cad, não foram observadas diferenças significativas para GA (p=0.9495). No entanto para GO, o material resinoso apresentou valores significativamente menores que o material cerâmico (p=0.0026). Para GM e DMA não indicou diferença significativa entre os grupos (p=0.8018). Para análise 3D, observou-se diferenças significativas entre as câmeras para a variável DCP (p=0.0212), sendo que a Bluecam apresentou os menores valores. Para o Lava Ultimate e Emax-cad, também foram observadas diferenças significativas para variável DCP, sendo que o material resinoso apresentou valores significativamente menores que o material cerâmico (p=0.0052). Conclusão: As adaptações marginais avaliadas de todos os grupos apresentaram valores dentro da normalidade. Observou-se uma melhor adaptação das coroas fabricadas com Lava Ultimate associado à câmera Bluecam quando comparado aos grupos em que a câmera Omnicam foi usada. O uso do microtomógrafo permitiu a avaliação 2D e 3D da desadaptação marginal entre o preparo dental e a restauração. / The aim of this in vitro study was to evaluate the quality of marginal and internal fit of full-crowns obtained from pre-fabricated blocks of Lava Ultimate 3M ESPE (nanoceramic resin) and IPS e.max CAD (lithium disilicate ceramic) with two intraoral cameras, Bluecam and OmniCam, usingmicro-tomography. Methods: Ten healthy human third molars were prepared to receive crowns. For each prepared molar, there were two digital impressions, one with Bluecam and the other with OmniCam. Four groups were formed: Group 1 (Lava Ultimate +Bluecam); Group 2 (Emax+Bluecam); Group 3 (Lava Ultimate+OmniCam); Group 4 (Emax+OmniCam). Before measuring the fit precision, all crowns were stabilized with a silicone material. After, each unit (crown + prepared tooth) was taken to the μCT and the marginal and internal discrepancy was analyzed by different software. A total of 120 measurements were performed in each crown: 40 for axial gap (GA), 40 for oclusal gap (GO), 20 for marginal gap (GM) e 20 for absolute marginal discrepancy (DMA). Results: Regarding internal adaptation, group 1 showed better GA values associated with lower value GO; while Group 4 showed low values of GA, but with high-value GO, thus suggesting the presence of premature contacts in the axial walls preventing better fit precision. Regarding marginal adaptation, no significant differences were observed. In assessing the mismatch between the crown and preparation (DCP) by the 3-D reconstruction, Group 1 presented significantly lower values as compared to groups 3 and 4. Conclusion: The marginal adaptations assessed in all groups showed values within the normal range. Moreover, the nanoceramic resin associated with the Bluecam intraoral showed the best results for marginal and internal adaptation when compared to the groups that used the Omnicam camera. The use of μCT provided a high resolution evaluation of marginal and internal gaps between tooth preparation and restoration, with a 2-D and 3-D assessment.
4

Moldagem digital

Silva, Júnio S. Almeida e January 2011 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia. / Made available in DSpace on 2012-10-25T17:31:02Z (GMT). No. of bitstreams: 1 301845.pdf: 115870214 bytes, checksum: aa98afe9cd6864bfc8b60a93d03adfcf (MD5) / O objetivo deste estudo in vitro foi comparar a precisão de moldagem da técnica digital com a precisão de moldagem da técnica convencional por meio da análise da adaptação marginal e interna de estruturas de próteses fixas (PFs) de zircônia de quatro elementos geradas por CAD/CAM. Materiais e Método: um modelo-mestre de titânio foi utilizado para a fabricação das estruturas de zircônia que foram divididas em dois grupos experimentais: MD (Moldagem Digital) e MC (Moldagem Convencional). Para o grupo MC, doze moldagens do modelo-mestre foram feitas com poliéter (Impregum, 3M ESPE) com o auxílio de moldeiras individuais; em seguida, os moldes foram vazados com gesso pedra Classe IV (Fujirock,GC), e troquelizados. Os doze troquéis foram escaneados pelo sistema de escaneamento óptico LavaTM Scan ST. Para o grupo MD, doze moldagens digitais do modelo-mestre foram realizadas com o sistema LavaTM C.O.S. As estruturas de zircônia de ambos os grupos foram usinadas a partir de blocos de zircônia semissinterizados. No intuito de confeccionar os espécimes relativos às fendas marginais e ao espaço interno de cimentação dos retentores das PFs, a técnica da réplica foi utilizada de modo que, para cada dente-pilar, fossem obtidas duas secções transversais (vestíbulo-lingual e mésio-distal). Fotografias dos espécimes foram tiradas com uma câmera acoplada a um microscópio óptico. As imagens microscópicas foram exportadas para um software de análise de imagens (Optimas 6.5), onde as mensurações da adaptações marginais e internas foram conduzidas. As médias dos valores foram analisadas por meio do teste estatístico Mann-Whitney-U. Resultados para a adaptação geral: O grupo MD (59,84 ?m) mostrou valor médio significantemente inferior ao grupo MC (67,79 ?m) P=0,01. Os grupos MD e MC demonstraram adaptação marginal com valores médios sem diferença estatística de 63,96 ?m e 65,33 ?m, respectivamente. Os grupos MD e MC apresentaram valores de adaptação interna significantemente diferentes de 58,46 ?m e 65,94 ?m, P=0,007, respectivamente. Conclusões: As PFs confeccionadas por meio de ambas as moldagens digital e convencional exibiram valores de adaptação marginal clinicamente aceitáveis. A moldagem digital gerou melhores valores de adaptações geral e interna do que a moldagem convencional. Considerando cada face dos dentes-pilares, um padrão heterogêneo de distribuição nos valores foi observado para as adaptações marginal e interna. / The aim of this in vitro study was to assess the precision of fit of CAD/CAM-generated four-unit zirconia fixed dental prostheses (FDPs) made through digital and conventional impressions. Material and method: a titanium master model was used as a basis for manufacturing the zirconia frameworks which were divided into two groups DI (Digital Impression) and CI (Conventional Impression). For group CI, twelve polyether impressions Impregum (3M ESPE) of the master model were made with aid of custom trays and poured in a Class IV stone (Fujirock). The twelve pin-models were scanned by an optical scanning device (LavaTM Scan ST). As for group DI, twelve digital impressions of the master model using LavaTM C.O.S. system were made. The frameworks of both groups were milled from semi-sintered zirconia. In order to obtain replicas of the marginal and internal gaps of the FDPs retainers, the replica technique was applied so that, per retainer, two cross-sectional specimens (buccal-palatal and mesio-distal) were obtained. Photographs of the specimens were taken with a digital camera which was attached to a microscope. The microscopic images were transferred to the imaging data software (Optimas 6.5), wherein the measurements of marginal and internal fit were carried out. Mean values were analyzed with descriptive statistics. Mann-Whitney-U statistical test was used to detect statistical differences between both investigated type of impressions in terms of marginal and internal fit for overall values and for values of different abutments faces. Results for overall fit: Group DI (59.84 ìm) showed significant lower mean value than group CI (67.79 ìm) P=0.01. Group DI and CI presented marginal fit of 63.96 ìm and 65.33 ìm, respectively, which showed no statistical difference. Groups DI and CI presented internal fit of 58.46 ìm and 65.94 ìm, respectively, which were statistically different, P=0.007. Conclusions: Both digital and conventional impressions tested showed clinically acceptable marginal fit. Digital impression demonstrated better overall and internal fit than conventional impression. Considering each abutment face, a heterogeneous distribution pattern was shown for internal and marginal fit.
5

Avaliação óptica da interação entre o selamento dentinário imediato e os materiais de moldagem

Melo, Fernando Vilain de 25 October 2012 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2011 / Made available in DSpace on 2012-10-25T21:12:08Z (GMT). No. of bitstreams: 1 292413.pdf: 44482746 bytes, checksum: 8276ec0995356543610089a6da991cd3 (MD5) / O objetivo deste trabalho foi avaliar a interação entre o selamento dentinário imediato (SDI), realizado com diferentes sistemas adesivos e tratamentos de superfície e materiais de moldagem a base de polivinilsiloxano e poliéter. Trezentos e sessenta (360) superfícies dentinárias planificadas de incisivos bovinos incluídos em resina acrílica foram utilizadas neste estudo . Três diferentes sistemas adesivos (Optibond FL, Scotchbond Multi Uso e Clearfil SE Bond) foram utilizados para simular o SDI. As superfície hibridizadas receberam 7 tratamentos superficiais distintos (nenhum, glicerina + fotoativação (FO), glicerina + FO + pedra-pomes, glicerina + FO + bicarbonato de sódio, glicerina + FO + álcool, resina flow, resina flow + glicerina + FO), alem de um grupo controle no qual não foi realizado o SDI. Cada superfície foi moldada utilizando 2 materiais de moldagem: um polivinilsiloxano(Express XT) e um poliéter (Impregum Soft). Cada superfície foi fotografada sob grande aumento antes e após as moldagens. As fotografias foram analisadas comparativamente em busca de resíduos de material de moldagem não polimerizado ou aderido às diferentes superfícies tratadas. As análises demonstraram que as superfícies dentinárias mais lisas e uniformes foram obtidas com a utilização do adesivo Optibond FL tratado com glicerina+FO ou com a utilização de uma resina flow. O polivinilsiloxano não apresentou qualquer interação negativa com as superfícies testadas. O poliéter sofreu inibição da sua polimerização quando utilizado sobre o Clearfill SE Bond (sem tratamento) e aderência à superfície hibridizada em diversos grupos. Quando foi utilizada a resina flow (resina flow e resina flow + glicerina + FO) não existiu interação alguma entre o poliéter e as superfícies. Conclui-se que o polivinilsiloxano não apresenta interação negativa com o SDI e apenas quando as superfícies dentinárias hibridizadas estiverem recobertas por uma fina camada de resina flow o poliéter poder ser utilizado como material de moldagem pós-SDI.
6

Vibrador portátil para vazamento de gesso

Andrade, Pâmela Cândida Aires Ribas de 24 October 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2010 / Made available in DSpace on 2012-10-24T22:51:54Z (GMT). No. of bitstreams: 1 279304.pdf: 1211484 bytes, checksum: 7676c2e7e604389e18e926d70a3edc81 (MD5) / Vazamentos de modelo para confecção de prótese sobre implante podem alterar a posição do análogo, tendo como consequência problema de desajuste da prótese. A proposta do presente estudo foi testar um vibrador portátil para vazamento de gesso (desenvolvido para esse fim), comparando-o com outras técnicas de vazamento com vibradores convencionais. A partir de um modelo mestre com 2 implantes, 30 moldagens de transferência foram realizadas e divididas em três grupos: Grupo I (GI): vazamento feito em laboratório de prótese terceirizado, com vibrador convencional (10 modelos); Grupo II (GII): vazamento no laboratório da Universidade Federal de Santa Catarina, com vibrador convencional (10 modelos); Grupo III (GIII): vazamento com vibrador portátil fabricado para este estudo (10 modelos). A posição dos análogos e adaptação marginal da infraestrutura foram verificadas pelo teste do parafuso único no modelo mestre e subsequentes modelos de trabalho, e a mensuração do desajuste foi realizada por um microscópio de precisão e unidade analisadora Quadra-Check 200. Os dados foram analisados estatisticamente pela análise de variância (ANOVA) e teste Holm-Sidak (? = 0,05). Os valores médios (?m) foram (média±dp): GI: 19,19±4,73?m, GII: 21,72±5,41?m, GIII: 13,5±2,39?m, sendo estes os valores estatisticamente inferiores aos dois primeiros grupos. Dentro das condições deste estudo, foi possível concluir que a maior precisão dos modelos de trabalho foi conseguida quando se utilizou o vibrador portátil para vazamento dos moldes.

Page generated in 0.0883 seconds