• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 43
  • 37
  • 12
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 105
  • 105
  • 58
  • 42
  • 28
  • 21
  • 20
  • 19
  • 18
  • 17
  • 15
  • 12
  • 12
  • 11
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Controlled and localized synthesis of molecularly imprinted polymers for chemical sensors / Synthèse localisée et contrôlée de polymères à empreintes moléculaires pour capteurs chimiques

Kaya, Zeynep 05 November 2015 (has links)
Les polymères à empreintes moléculaires (MIP), également appelés "anticorps en plastique", sont des récepteurs biomimétiques synthétiques qui sont capables de reconnaître et lier une molécule cible avec une affinité et une spécificité comparables à celles des récepteurs naturels tels que des enzymes ou des anticorps. En effet, les MIP sont utilisés comme éléments de reconnaissance synthétiques dans les biocapteurs et biopuces pour la détection de petits analytes et les protéines. La technique d'impression moléculaire est basée sur la formation de cavités de reconnaissance spécifiques dans des matrices polymères par un procédé de moulage à l'échelle moléculaire. Pour la conception de capteurs et biopuces, une cinétique d'adsorption et une réponse du capteur rapide, l'intégration des polymères avec des transducteurs, et une haute sensibilité de détection sont parmi les principaux défis. Dans cette thèse, ces problèmes ont été abordés par le développement de nanocomposites MIP / d'or via le greffage du MIP sur les surfaces en utilisant des techniques de polymérisation dédiées comme l'ATRP qui est une technique de polymérisation radicalaire contrôlée (CRP). Ces techniques CRP sophistiquées sont en mesure d'améliorer considérablement les matériaux polymères. L'utilisation de l'ATRP dans le domaine de MIP a été limitée jusqu'à présent en raison de son incompatibilité inhérente avec des monomères acides comme l'acide méthacrylique (MAA), qui est de loin le monomère fonctionnel le plus largement utilisé dans les MIP. Ici, un nouveau procédé est décrit pour la synthèse de MIP par ATRP photo-initiée utilisant fac-[Ir(Ppy)3] comme catalyseur. La synthèse est possible à température ambiante et est compatible avec des monomères acides. Cette étude élargit considérablement la gamme de monomères fonctionnels et de molécules empreintes qui peuvent être utilisés lors de la synthèse de MIP par ATRP. La méthode proposée a été utilisée pour la fabrication de nanocomposites hiérarchiquement organisés sur des surfaces métalliques nanostructurés avec des nano-trous et nano-ilots, présentant des effets plasmoniques pour l'amplification du signal. La synthèse de films de MIP à l'échelle du nanomètre localisés sur la surface d'or a été démontrée. Des méthodes de transduction optiques, à savoir la résonance de plasmons de surface localisée (LSPR) et la spectroscopie Raman exaltée par effet de surface (SERS) ont été exploitées. Ces techniques se sont montrées prometteuses pour l'amélioration de la limite de détection dans la détection d'analytes biologiquement pertinents, y compris les protéines et le médicament propranolol. / Molecularly imprinted polymers (MIPs), also referred to as plastic antibodies, are synthetic biomimetic receptors that are able to bind target molecules with similar affinity and specificity as natural receptors such as enzymes or antibodies. Indeed, MIPs are used as synthetic recognition elements in biosensors and biochips for the detection of small analytes and proteins. The molecular imprinting technique is based on the formation of specific recognition cavities in polymer matrices by a templating process at the molecular level. For sensor and biochip development, fast binding kinetics of the MIP for a rapid sensor response, the integration of the polymers with transducers, and a high sensitivity of detection are among the main challenges. In this thesis, the above issues are addressed by developing MIP/gold nanocomposites by grafting MIPs on surfaces, using dedicated techniques like atom transfer radical polymerization (ATRP) which is a versatile controlled radical polymerization (CRP) technique. Theses ophisticated CRP techniques, are able to greatly improve the polymeric materials. The use of ATRP in the MIP field has been limited so far due to its inherent incompatibility with acidic monomers like methacrylic acid (MAA), which is by far the most widely used functional monomer. Herein, a new method is described for the MIP synthesis through photo-initiated ATRP using fac-[Ir(ppy)3] as ATRP catalyst. The synthesis is possible at room temperature and is compatible with acidic monomers. This study considerably widens the range of functional monomers and thus molecular templates that can be used when MIPs are synthesized by ATRP. The proposed method was used for fabrication of hierarchically organised nanocomposites based on MIPs and nanostructured metal surfaces containing nanoholes or nanoislands, exhibiting plasmonic effects for signal amplification. The fabrication of nanometer scale MIP coatings localized on gold surface was demonstrated. Optical transduction methods, namely Localized Surface Plasmon Resonance (LSPR) and Surface Enhanced Raman Spectroscopy (SERS) were exploited and shown that they hold great promise for enhancing the limit of detection in sensing of biologically relevant analytes including proteins and the drug propranolol.
102

Développement de méthodes d'extraction et d'analyse multi-résidus pour le suivi de contaminants organiques polyaromatiques et de métabolites oxygénés dans les sédiments / Development of multiresidual extractions and analytical methodologies for polyaromatic organic contaminants and oxygenated metabolites in sediments

Brito-Berger, Ingrid 03 September 2018 (has links)
Dans ce travail, deux méthodes d'extraction multi-résidus de contaminants présents dans des sédiments ont été développées. Dans la première partie de cette étude, une méthode a été développée pour l’'extraction simultanée de deux familles de métabolites oxygénés d'hydrocarbures aromatiques polycycliques (HAP), les quinones et les HAP hydroxylés (OH-HAP). Une approche chimiométrique a permis de déterminer les paramètres influant sur l’extraction assistée par micro-ondes (MAE) et une zone de compromis a été trouvée pour extraire de manière optimale les deux familles de composés. Deux méthodologies d’analyses chromatographiques ont été développées et validées pour analyser les extraits, puis comparées, à savoir la chromatographie liquide haute performance couplée aux détections UV et fluorimétrique (HPLC-UV-Fluo) et la chromatographie en phase gazeuse couplée à un spectromètre de masse par impact électronique (CPG-SM). En CPG-SM, des réactions de silylation des OH-HAP et d’acétylation des quinones ont dû être mises au point, afin d’abaisser les limites de détection (LD), en particulier pour les ortho-quinones. En HPLC-UV-Fluo, les LD étaient plus faibles qu’en CPG-SM, surtout pour les OH-HAP détectés en Fluo et l'analyse était plus rapide, sans processus de dérivation; mais la détection n’étant pas sélective, l’identification des analytes s’est avérée hazardeuse. Le choix s’est donc porté sur la CPG-SM pour une analyse plus fiable des deux familles de composés de matrices sédimentaires naturellement contaminées. Dans la deuxième partie de ce travail de thèse, une nouvelle méthodologie d'extraction a été développée et validée, basée sur la dispersion en phase solide de la matrice solide (MSPD), capable d'extraire mais aussi de purifier l’échantillon, méthodologie par ailleurs simple et rapide. Deux familles de composés ont été extraits simultanément à partir de sédiments, les HAP et les polychlorobiphényles (PCB). Un certain nombre de paramètres ont été optimisés, tels la nature des agents dispersants, le temps de broyage, le volume et la nature du mélange de solvants d’élution. Dans un deuxième temps, l'introduction des OH-HAP dans le processus analytique a amené à coupler à la MSPD une autre méthode d’extraction/purification beaucoup plus sélective, basée sur les polymères à empreintes moléculaires (MIP). En effet, les interférents polaires, restés piégés par l’agent dispersant polaire dans la première cartouche contenant le sédiment broyé, devaient être élués afin de libérer les OH-HAP, qui a leur tour devaient être retenus sélectivement dans un MIP empreint pour les phénols, pour fournir une élution finale exempte d'autres composés. Il a été montré que ces MIPs pouvaient extraire sélectivement les OH-HAP de faible et de haut poids moléculaire, mais il fallait choisir soigneusement le solvant de percolation pour ne pas endommager le polymère. Cependant, la difficulté principale a été de désorber les OH-HAP fortement retenus par le sédiment par liaison hydrogène. Cela a pu être réalisé pour les OH-HAP légers, en utilisant un mélange de solvants avec un effet de relargage par un sel, mais pas pour les OH-HAP lourds, trop fortement adsorbés sur la matrice sédimentaire. Par ailleurs, il a fallu utiliser une grande quantité de polymère à empreinte moléculaire à cause de la compétition pour les sites de reconnaissance entre les OH-HAP et des composés phénoliques. / In this work two multiresidual methods for extracting contaminants from sediments were developed. In the first part of this study, a method was developed for extracting simultaneously two groups of oxygenated metabolites of polycyclic aromatic hydrocarbons (PAHs), quinones and hydroxylated PAHs (hydroxy-PAHs). A chemometric approach allowed us to determine the influential parameters on microwave assisted extraction (MAE), and a compromise could be found for extracting quantitatively both families of compounds. Two chromatographic analytical methodologies were developed and validated for analysing the extracts: high performance liquid chromatography coupled with fluorimetric and ultraviolet detection (HPLC-UV-FLD) and gas chromatography coupled with an electronic impact mass spectrometer (GC-MS). Using GC-MS, reactions of silylation of hydroxy-PAHs and of acetylation of quinones had to be developed, to decrease detection limits (LOD), particularly for ortho-quinones. Using HPLC-UV-FLD, LODs were lower than using GC-MS, particularly for hydroxy-PAHs detected by FLD, and the analysis was faster, without derivatization; but the detectors were not selective, and identification of analytes was doubtful. Choice was done to favour GC-MS for a more reliable analysis of the two families of compounds extracted from naturally contaminated sediments. In the second part of this thesis work, a new fast and simple extraction methodology was developed and validated, based on matrix solid phase dispersion (MSPD), capable of extracting and purifying simultaneously sediment samples. Two families of compounds were simultaneously extracted from sediments, PAHs and polychlorobiphenyls (PCBs). Many parameters were optimized, as the nature of dispersing agents, the time of grinding, the volume and nature of elution solvent mixtures. In a second step, hydroxy-PAHs were introduced in the analytical process, which led us to add another more selective extraction/purification method to MSPD, based on molecularly imprinted polymers (MIPs). Indeed polar interfering compounds, trapped by the polar dispersant in the first cartridge containing the blended sediment, had to be eluted to release hydroxy-PAHs, which in turn had to be selectively retained by the polymer, imprinted for phenols, to provide a final eluate free from other polar compounds. It was demonstrated that those MIPs could selectively extract low and high molecular weight hydroxy-PAHs, but appropriate percolating solvents had to be chosen to avoid polymer damages. However, the main difficulty was to desorb hydroxy-PAHs strongly retained by the sediment matrix through hydrogen bonds. It could be achieved for light hydroxy-PAHs, using a mixture of eluting solvents with salting-out effect, but not for heavy hydroxy-PAHs which stayed strongly sorbed on the sediment matrix. Furthermore we needed to use high amounts of imprinted polymer because of the competition for recognition sites between hydroxy-PAHs and phenolic compounds.
103

Molecularly Imprinted Polymer-Based Sensors for Priority Pollutants

Zarejousheghani, Mashaalah, Rahimi, Parvaneh, Borsdorf, Helko, Zimmermann, Stefan, Joseph, Yvonne 08 July 2024 (has links)
Globally, there is growing concern about the health risks of water and air pollution. The U.S. Environmental Protection Agency (EPA) has developed a list of priority pollutants containing 129 different chemical compounds. All of these chemicals are of significant interest due to their serious health and safety issues. Permanent exposure to some concentrations of these chemicals can cause severe and irrecoverable health effects, which can be easily prevented by their early identification. Molecularly imprinted polymers (MIPs) offer great potential for selective adsorption of chemicals from water and air samples. These selective artificial bio(mimetic) receptors are promising candidates for modification of sensors, especially disposable sensors, due to their low-cost, long-term stability, ease of engineering, simplicity of production and their applicability for a wide range of targets. Herein, innovative strategies used to develop MIP-based sensors for EPA priority pollutants will be reviewed.
104

Entwicklung eines miniaturisierten Fluoreszenzsensors basierend auf molekular geprägten Polymeren / Development of a miniaturized fluorescence sensor based on molecularly imprinted polymers

Kunath, Stephanie 03 June 2013 (has links) (PDF)
Die vorliegende Arbeit befasst sich mit der Entwicklung von Biosensoren mit dem Ziel, mit Hilfe der Kopplung molekular geprägter Polymere (MIPs) als neuartiges Rezeptormaterial und dem sensitiven Nachweisprinzip der Fluoreszenz eine neue Qualität des Analytnachweises zu erreichen. Es wurde eine neue Strategie zur Optimierung der Bindungseigenschaften von molekular geprägten Polymeren in wässrigen Lösungsmitteln entwickelt, die die Kopplung aus Design of Experiments und der Optimierung multipler Zielgrößen umfasst. Damit konnten die Polymerbindungseigenschaften für alle vier betrachteten Parameter wesentlich verbessert werden. Mit Hilfe stationärer und zeitaufgelöster Fluoreszenztechniken wurde die Aufklärung der Wechselwirkung zwischen MIP und Analyt auf molekularer Ebene sowie die Charakterisierung einer neuen Nachweisstrategie basierend auf einen Förster-Resonanzenergietransfer-Mechanismus realisiert. Es wurde ferner ein MIP-Sensor für biologische Proben mit mikrofluidischer Probenzuführung aufgebaut und mittels Fluoreszenzspektrometer als konventionelles Nachweisverfahren etabliert. Darauf aufbauend wurde der optische Nachweis miniaturisiert und somit miniaturisierte Lichtquellen und Detektoren sowie eine faser-optische Lichtleitung eingesetzt. Davon ausgehend erfolgte die Optimierung des Messaufbaus hinsichtlich der Sensitivität und Nachweisgrenze des fluoreszierenden Analyten. Schließlich wurden erstmalig fluoreszenzmarkierte MIP-Partikel zur Lokalisation und Quantifizierung auf Zelloberflächen eingesetzt, d.h. diese dienten als Antikörperersatz der Immunfärbung. / This thesis deals with the development of biosensors with the aim to couple molecularly imprinted polymers (MIPs) as new receptor material with the sensitive detection principle of fluorescence in order to improve analyte detection. A new strategy for optimization of binding parameters of molecularly imprinted polymers in aqueous media was developed which is based on the coupling of design of experiments and the optimization of multiple objective parameters. Due to that the polymer binding properties for all four considered parameters could be optimized considerably. With the help of steady state and time-resolved fluorescence techniques the interaction between MIP and analyte could be clarified on a molecular basis. Furthermore the characterization of a new detection strategy based on a Förster resonance energy transfer mechanism was realized. Moreover a MIP sensor with microfluidic sample handling for biological samples was built-up and established with fluorescence spectroscopy as conventional detection method. Based on that, the optical detection was miniaturized with respect to light sources, detectors as well as optical fibers for light guidance. This set-up was optimized concerning sensitivity and limit of detection of the fluorescent analyte. Finally, for the first time fluorescently marked MIP particles were applied for imaging on cell surfaces – meaning that they were used for immunostaining as antibody mimics.
105

Entwicklung eines miniaturisierten Fluoreszenzsensors basierend auf molekular geprägten Polymeren

Kunath, Stephanie 18 February 2013 (has links)
Die vorliegende Arbeit befasst sich mit der Entwicklung von Biosensoren mit dem Ziel, mit Hilfe der Kopplung molekular geprägter Polymere (MIPs) als neuartiges Rezeptormaterial und dem sensitiven Nachweisprinzip der Fluoreszenz eine neue Qualität des Analytnachweises zu erreichen. Es wurde eine neue Strategie zur Optimierung der Bindungseigenschaften von molekular geprägten Polymeren in wässrigen Lösungsmitteln entwickelt, die die Kopplung aus Design of Experiments und der Optimierung multipler Zielgrößen umfasst. Damit konnten die Polymerbindungseigenschaften für alle vier betrachteten Parameter wesentlich verbessert werden. Mit Hilfe stationärer und zeitaufgelöster Fluoreszenztechniken wurde die Aufklärung der Wechselwirkung zwischen MIP und Analyt auf molekularer Ebene sowie die Charakterisierung einer neuen Nachweisstrategie basierend auf einen Förster-Resonanzenergietransfer-Mechanismus realisiert. Es wurde ferner ein MIP-Sensor für biologische Proben mit mikrofluidischer Probenzuführung aufgebaut und mittels Fluoreszenzspektrometer als konventionelles Nachweisverfahren etabliert. Darauf aufbauend wurde der optische Nachweis miniaturisiert und somit miniaturisierte Lichtquellen und Detektoren sowie eine faser-optische Lichtleitung eingesetzt. Davon ausgehend erfolgte die Optimierung des Messaufbaus hinsichtlich der Sensitivität und Nachweisgrenze des fluoreszierenden Analyten. Schließlich wurden erstmalig fluoreszenzmarkierte MIP-Partikel zur Lokalisation und Quantifizierung auf Zelloberflächen eingesetzt, d.h. diese dienten als Antikörperersatz der Immunfärbung. / This thesis deals with the development of biosensors with the aim to couple molecularly imprinted polymers (MIPs) as new receptor material with the sensitive detection principle of fluorescence in order to improve analyte detection. A new strategy for optimization of binding parameters of molecularly imprinted polymers in aqueous media was developed which is based on the coupling of design of experiments and the optimization of multiple objective parameters. Due to that the polymer binding properties for all four considered parameters could be optimized considerably. With the help of steady state and time-resolved fluorescence techniques the interaction between MIP and analyte could be clarified on a molecular basis. Furthermore the characterization of a new detection strategy based on a Förster resonance energy transfer mechanism was realized. Moreover a MIP sensor with microfluidic sample handling for biological samples was built-up and established with fluorescence spectroscopy as conventional detection method. Based on that, the optical detection was miniaturized with respect to light sources, detectors as well as optical fibers for light guidance. This set-up was optimized concerning sensitivity and limit of detection of the fluorescent analyte. Finally, for the first time fluorescently marked MIP particles were applied for imaging on cell surfaces – meaning that they were used for immunostaining as antibody mimics.

Page generated in 0.0893 seconds