• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • 1
  • Tagged with
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Simulation of Metal and Metal Oxide Nanoparticle Sedimentation in Solution Using a Computational Model

Isaksson, Sara January 2016 (has links)
Nanoparticles are used in many different applications because of their small size and unique properties. The usage is increasing rapidly, which will increase the nanoparticle exposure to the environment. Up till now, environmental behavior and ecotoxicology of nanoparticles have only been studied to a certain extent and because of the increasing usage, research should focus more on nanoparticle behavior and ecotoxicology. An effective way of studying nanoparticles in aqueous environments is to use mathematical models. In this study, the In vitro Sedimentation, Diffusion, and Dosimetry (ISDD) model was investigated and applied to copper, manganese, and zinc oxide nanoparticles to determine their sedimentation velocity in 1 mM NaClO4(aq).   The results show that the simulated sedimentation of nanoparticles in solution, i.e. the output from the ISDD model, can vary a lot depending on some of the input parameters in the model. The fact that some of these parameters have to be estimated increases the uncertainty of the ISDD model, although it is possible to yield results in great agreement with experimentally determined sedimentation velocities for the studied systems. The simulation results could always be explained by the theory behind it, which increases the reliability of the ISDD model.   The possibility of measuring the effective density of nanoparticle agglomerates using the volumetric centrifugation method was also investigated. This method makes it possible to avoid estimating the fractal dimension, an input parameter with great uncertainty in the ISDD model. The results look promising, although further investigation is needed.    The ISDD model seems to be a promising model for future simulation work. The model should be investigated further in order to minimize the uncertainties due to estimations. The possibility to predict nanoparticle sedimentation using a mathematical model will save a lot of time and money, and it can be a helpful tool in the extensive work of identifying the behavior of nanoparticles in aqueous environments.
2

A study of the susceptibility to stress corrosion cracking of AISI 1018 carbon steel under low NO <sub>2</sub>-air aqueous environment

Wu, Hou-Chen January 1992 (has links)
No description available.
3

Entwicklung eines miniaturisierten Fluoreszenzsensors basierend auf molekular geprägten Polymeren / Development of a miniaturized fluorescence sensor based on molecularly imprinted polymers

Kunath, Stephanie 03 June 2013 (has links) (PDF)
Die vorliegende Arbeit befasst sich mit der Entwicklung von Biosensoren mit dem Ziel, mit Hilfe der Kopplung molekular geprägter Polymere (MIPs) als neuartiges Rezeptormaterial und dem sensitiven Nachweisprinzip der Fluoreszenz eine neue Qualität des Analytnachweises zu erreichen. Es wurde eine neue Strategie zur Optimierung der Bindungseigenschaften von molekular geprägten Polymeren in wässrigen Lösungsmitteln entwickelt, die die Kopplung aus Design of Experiments und der Optimierung multipler Zielgrößen umfasst. Damit konnten die Polymerbindungseigenschaften für alle vier betrachteten Parameter wesentlich verbessert werden. Mit Hilfe stationärer und zeitaufgelöster Fluoreszenztechniken wurde die Aufklärung der Wechselwirkung zwischen MIP und Analyt auf molekularer Ebene sowie die Charakterisierung einer neuen Nachweisstrategie basierend auf einen Förster-Resonanzenergietransfer-Mechanismus realisiert. Es wurde ferner ein MIP-Sensor für biologische Proben mit mikrofluidischer Probenzuführung aufgebaut und mittels Fluoreszenzspektrometer als konventionelles Nachweisverfahren etabliert. Darauf aufbauend wurde der optische Nachweis miniaturisiert und somit miniaturisierte Lichtquellen und Detektoren sowie eine faser-optische Lichtleitung eingesetzt. Davon ausgehend erfolgte die Optimierung des Messaufbaus hinsichtlich der Sensitivität und Nachweisgrenze des fluoreszierenden Analyten. Schließlich wurden erstmalig fluoreszenzmarkierte MIP-Partikel zur Lokalisation und Quantifizierung auf Zelloberflächen eingesetzt, d.h. diese dienten als Antikörperersatz der Immunfärbung. / This thesis deals with the development of biosensors with the aim to couple molecularly imprinted polymers (MIPs) as new receptor material with the sensitive detection principle of fluorescence in order to improve analyte detection. A new strategy for optimization of binding parameters of molecularly imprinted polymers in aqueous media was developed which is based on the coupling of design of experiments and the optimization of multiple objective parameters. Due to that the polymer binding properties for all four considered parameters could be optimized considerably. With the help of steady state and time-resolved fluorescence techniques the interaction between MIP and analyte could be clarified on a molecular basis. Furthermore the characterization of a new detection strategy based on a Förster resonance energy transfer mechanism was realized. Moreover a MIP sensor with microfluidic sample handling for biological samples was built-up and established with fluorescence spectroscopy as conventional detection method. Based on that, the optical detection was miniaturized with respect to light sources, detectors as well as optical fibers for light guidance. This set-up was optimized concerning sensitivity and limit of detection of the fluorescent analyte. Finally, for the first time fluorescently marked MIP particles were applied for imaging on cell surfaces – meaning that they were used for immunostaining as antibody mimics.
4

Entwicklung eines miniaturisierten Fluoreszenzsensors basierend auf molekular geprägten Polymeren

Kunath, Stephanie 18 February 2013 (has links)
Die vorliegende Arbeit befasst sich mit der Entwicklung von Biosensoren mit dem Ziel, mit Hilfe der Kopplung molekular geprägter Polymere (MIPs) als neuartiges Rezeptormaterial und dem sensitiven Nachweisprinzip der Fluoreszenz eine neue Qualität des Analytnachweises zu erreichen. Es wurde eine neue Strategie zur Optimierung der Bindungseigenschaften von molekular geprägten Polymeren in wässrigen Lösungsmitteln entwickelt, die die Kopplung aus Design of Experiments und der Optimierung multipler Zielgrößen umfasst. Damit konnten die Polymerbindungseigenschaften für alle vier betrachteten Parameter wesentlich verbessert werden. Mit Hilfe stationärer und zeitaufgelöster Fluoreszenztechniken wurde die Aufklärung der Wechselwirkung zwischen MIP und Analyt auf molekularer Ebene sowie die Charakterisierung einer neuen Nachweisstrategie basierend auf einen Förster-Resonanzenergietransfer-Mechanismus realisiert. Es wurde ferner ein MIP-Sensor für biologische Proben mit mikrofluidischer Probenzuführung aufgebaut und mittels Fluoreszenzspektrometer als konventionelles Nachweisverfahren etabliert. Darauf aufbauend wurde der optische Nachweis miniaturisiert und somit miniaturisierte Lichtquellen und Detektoren sowie eine faser-optische Lichtleitung eingesetzt. Davon ausgehend erfolgte die Optimierung des Messaufbaus hinsichtlich der Sensitivität und Nachweisgrenze des fluoreszierenden Analyten. Schließlich wurden erstmalig fluoreszenzmarkierte MIP-Partikel zur Lokalisation und Quantifizierung auf Zelloberflächen eingesetzt, d.h. diese dienten als Antikörperersatz der Immunfärbung. / This thesis deals with the development of biosensors with the aim to couple molecularly imprinted polymers (MIPs) as new receptor material with the sensitive detection principle of fluorescence in order to improve analyte detection. A new strategy for optimization of binding parameters of molecularly imprinted polymers in aqueous media was developed which is based on the coupling of design of experiments and the optimization of multiple objective parameters. Due to that the polymer binding properties for all four considered parameters could be optimized considerably. With the help of steady state and time-resolved fluorescence techniques the interaction between MIP and analyte could be clarified on a molecular basis. Furthermore the characterization of a new detection strategy based on a Förster resonance energy transfer mechanism was realized. Moreover a MIP sensor with microfluidic sample handling for biological samples was built-up and established with fluorescence spectroscopy as conventional detection method. Based on that, the optical detection was miniaturized with respect to light sources, detectors as well as optical fibers for light guidance. This set-up was optimized concerning sensitivity and limit of detection of the fluorescent analyte. Finally, for the first time fluorescently marked MIP particles were applied for imaging on cell surfaces – meaning that they were used for immunostaining as antibody mimics.

Page generated in 0.0838 seconds