• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 11
  • 6
  • 1
  • Tagged with
  • 16
  • 16
  • 16
  • 13
  • 11
  • 10
  • 4
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Polymères à empreinte moléculaire pour la détection rapide des résidus de tétracyclines dans le lait

Zouaoui, Hamza January 2007 (has links)
Mémoire numérisé par la Division de la gestion de documents et des archives de l'Université de Montréal.
2

Polymères à empreinte moléculaire pour la détection rapide des résidus de tétracyclines dans le lait

Zouaoui, Hamza January 2007 (has links)
Mémoire numérisé par la Division de la gestion de documents et des archives de l'Université de Montréal
3

Conception de polymères à empreintes moléculaires pour l'extraction de principes actifs de produits naturels / Development of molecularly imprinted polymers to extract active ingredients from natural products

Henry, Nathaly 10 May 2012 (has links)
L'industrie cosmétique a un recours croissant aux espèces végétales comme sources de principesactifs naturels. Leur extraction nécessite des supports sélectifs tels que les polymères à empreintesmoléculaires (MIP). Les travaux de cette thèse reposent sur le développement de MIP pourl’extraction sélective de la glucosamine, de la fructosazine et de la 2,5-déoxyfructosazine.Dans une première partie, trois approches ont été développées pour extraire la glucosamine par desMIP : l’approche covalente, semi-covalente et non covalente. Pour chacune, les différents paramètresintervenant dans la synthèse des MIP ont été optimisés. Les meilleurs résultats ont été obtenus avecun MIP synthétisé selon une approche non covalente ionique reposant sur la complexation de laglucosamine par un acide sulfonique. Les performances du MIP se sont avérées supérieures à cellesde supports commerciaux et des extractions à partir de végétaux ont été réalisées. Le potentielindustrialisable du MIP a été validé lors de premiers tests à plus grande échelle.Dans une deuxième partie, l’extraction simultanée de la fructosazine et de la 2,5-déoxyfructosazine aété réalisée suite au développement d’un MIP synthétisé selon une approche covalente reposant surla formation d’esters boroniques. Une méthode de synthèse originale est exposée puisque lestemplates ont été formés in situ lors de la polymérisation. Le MIP obtenu s’est avéré sélectif dechaque composé et a permis de purifier et de séparer la fructosazine et la 2,5-déoxyfructosazine dematrices végétales et alimentaires.Tous ces travaux ont été réalisés dans une démarche éco-responsable s’appuyant sur l’emploi desolvants aqueux lors de la polymérisation et de l’extraction. / The cosmetic industry uses plants as sources of natural active ingredients. The extraction of theseactive ingredients requires selective extraction method such as molecularly imprinted polymers (MIP)technique. This thesis describes the development of MIP for the selective extraction of glucosamine,fructosazine and 2,5-déoxyfructosazine.In the first part, three approaches were developed to extract glucosamine by MIP technique: thecovalent approach, semi-covalent and noncovalent. For each approach, the various parametersinvolved in the synthesis of the MIP were optimized. The best results were obtained with a MIPsynthesized with a non-covalent ionic approach based on the complexation of glucosamine by asulfonic acid. The MIP exhibits higher performance than commercial media and extractions fromplants were performed. The potential for industrialization of the MIP was validated during initial testson a larger scale.In the second part, the simultaneous extraction of fructosazine and 2,5-déoxyfructosazine wasperformed following the development of a MIP synthesized using a covalent approach based on theformation of boronic esters. An original synthesis method is exposed since the templates were formedin situ during the polymerization. The MIP obtained showed good selectivity for each compound andallowed to separate and purify fructosazine and 2,5-déoxyfructosazine from plant and food matrices.All these works were performed according to an eco-friendly approach based on the use of aqueoussolvents as solvents for polymerization and extraction.
4

Towards controlled release of Vanillin and bio-sensing of Adenosine monophosphate using molecularly imprinted polymers / Vers la libération contrôlée de Vanilline et le biocapteur d'Adénosine monophosphate en utilisant polymères à empreintes moléculaires

Puzio, Kinga 19 December 2012 (has links)
Ce mémoire présente une exploration des polymères à empreintes moléculaires (MIP) comme outils d’une libération contrôlée de bioactifs olfactifs ou pour le criblage/préselection de composés à activité antivirales ou anti-tumorales sur le site actif d’une enzyme. La première partie est une étude de la complexation de la vanilline sur des billes polymériques sphériques en vue d’une libération contrôlée (pH, salinité, …). Ces études portent sur les caractéristiques de l'absorption et la libération de la molécule d'intérêt dans le milieu aqueux sur les microsphères fonctionnalisées fourni par Merck ESTAPOR® Microsphères. Nous avons ensuite synthétisé divers MIP de vanilline au format monolithique. Plusieurs stratégies d’impression ont été étudiées: non covalente, covalente et semi-covalente. La composition du MIP préparé dans chaque approche a été optimisée pour obtenir les meilleures propriétés et performances. L'affinité, la sélectivité et la capacité du MIP ont été déterminées. Les MIPs ont été évalués par extraction en phase solide (SPE) d'analogues structuraux de la vanilline dans des échantillons naturels (extrait de vanille, vin). La deuxième partie de ce mémoire concerne l’évaluation de MIPs de l’adénosine 5’-monophosphate (AMP) Le polymère a été préparé par une approche non-covalente et son efficacité de recapture a été caractérisée par analyse frontale (FA). L’analyse frontale est une technique qui permet de discriminer des interactions spécifiques des non spécifiques et de comprendre les mécanismes de liaison dans des cavités spécifiques. / This thesis report presents the exploration of molecularly imprinted polymers (MIP) for the application in controlled release and targeting antivirus and anticancer drugs. The first part of this study describes the imprinting of vanillin as a monolith. Several strategies were studied: non-covalent, covalent and semi-covalent. The composition of the MIP prepared in each approach was optimized to obtain the best properties and performance. The affinity, selectivity and capacity of MIP were determined. MIPs were evaluated in solid-phase extraction (SPE) of structural analogues in natural samples (vanilla extract, wine). We also present the study of the exploration of spherical beads as potential tools for the controlled release of vanillin. These studies concern the characteristics of uptake and release of the molecule of interest in the aqueous medium on functionalised microspheres supplied by Merck ESTAPOR Microspheres®. The second part of this thesis is devoted to studies on the evaluation of MIP of adenosine 5'-monophosphate (AMP). The polymer was prepared in non-covalent approach and efficiency of binding was characterised using frontal analysis (FA). FA is a useful technique that allows discriminate specific and nonspecific interactions and to understand the binding mechanisms in specific cavities.
5

Fiber optic chemical sensors based on molecularly imprinted polymers for the detection of mycotoxins / Capteurs chimiques à fibres optiques utilisant les polymères à empreintes moléculaires pour la détection des mycotoxines

Ton, Xuan-Anh 25 October 2013 (has links)
Cette thèse décrit le développement de capteurs à fibre optique hautement sélectifs, utilisant des polymères à empreintes moléculaires (MIPs, de l’anglais molecularly imprinted polymers) comme éléments de reconnaissance, et se basant sur la fluorescence pour la détection. Nous avons étendu l’étude à d’autres types de capteurs et de méthodes de détection optiques, toujours basés sur les MIPs. Les MIPs sont des récepteurs synthétiques biomimétiques possédant des cavités spécifiques pour une molécule cible. Produits par un processus de moulage à l’échelle moléculaire, les MIPs sont capables de reconnaître et de se lier à leurs molécules cibles, avec des spécificités et affinités comparables aux récepteurs naturels. De plus, comparé aux récepteurs biologiques, les MIPs sont plus stables, moins chers et plus faciles à intégrer dans les procédés standard industriels de fabrication. Ainsi, les MIPs apparaissent comme une alternative intéressante aux biomolécules entant qu’éléments de reconnaissance dans les biocapteurs. Dans la première partie de la thèse (Chapitre 2), les MIPs ont été synthétisés en tant que micropointe à l’extrémité d’une fibre optique, par polymérisation in-situ induite par un laser en seulement quelques secondes. Les paramètres photoniques et physico-chimiques ont été optimisés pour moduler les propriétés des micro-objets de polymères. Des nanoparticules d’or ont été incorporées dans la micropointe de MIP afin d’induire une exaltation du signal. Afin de prouver l’efficacité de notre capteur, les études initiales ont été réalisées avec un MIP synthétisé avec le Ncarbobenzyloxy- L-phenylalanine (Z-L-Phe) comme template et le dérivé d’acide aminé fluorescentdansyl-L-phenylalanine, comme analyte. La fluorescence a été collectée de l’extérieur au niveau de la micropointe par une fibre optique connectée à un spectrofluorimètre, ou par collection du signal fluorescent ré-émis dans l’un des bras d’une fibre bifurquée en Y. L’analyse fluorescent a pu être détecté à des concentrations de l’ordre du nM. Afin de quantifier les analytes non fluorescents, un monomère fluorescent, possédant un groupe naphthalimide, a été incorporé dans le MIP ; celui-çidéployant une augmentation de la fluorescence quand l’analyte se lie. Utilisant ce système avec un MIP spécifique pour l’herbicide 2,4-D (acide 2,4-dichlorophénoxyacétique), des concentrations aussi basses que 2,5 nM en 2,4-D ont pu être mesurées. Le capteur MIP a également été appliqué à des analytes d’intérêt pour la sécurité alimentaire et le domaine nanostructurées. Cette étude pose les bases pour le développement futur de nanocapteurs et de Dans la dernière partie (Chapitre 4), une méthode d’analyse novatrice, basée sur l’utilisation des MIPs et l’analyse par polarisation de fluorescence, a été développée en vue de permettre la quantification directe et rapide d’analytes dans des échantillons alimentaires et environnementaux. Cette technique a été appliquée avec succès pour détecter des antibiotiques fluoroquinolones dans l’eau du robinet et le lait, en-dessous de leur limite maximale de résidus. En conclusion, nous pouvons dire que ce travail ouvre la voie vers l'application d'une nouvelle génération de capteurs optiques portables, robustes et miniaturisables basés sur les MIPs, pour des mesures «sur-site » et la quantification en temps réel d’analytes biologiques et environnementaux dans des milieux complexes. / This thesis describes the development of highly selective fiber optic sensors using molecularly imprinted polymers (MIPs) as recognition elements associated with fluorescence for detection. Additionally, we extended the study to the development of other MIP-based optical sensors and sensing methods. MIPs are synthetic biomimetic receptors possessing specific cavities designed for a target molecule. Produced by a templating process at the molecular level, MIPs are capable of recognizingand binding target molecules with selectivities and affinities comparable to those of natural receptors. Compared to biological recognition elements, MIPs are more stable, cheaper and easier to integrate into standard industrial fabrication processes. Hence, MIPs have become interesting alternatives to biomolecules as recognition elements for biosensing. In the first part of this thesis (Chapter 2), MIPs were synthesized by in-situ laser-induced photopolymerization in only a few seconds, as a micrometer-sized tip at the extremity of a telecommunication optical fiber. Photonic and physico-chemical parameters were optimized to tailor the properties of the polymer micro-objects. Gold nanoparticles were incorporated into the MIP microtip for signal enhancement. To prove the efficiency of the sensor, initial studies were performed with a MIP templated with N-carbobenzyloxy-L-phenylalanine (Z-L-Phe) and the fluorescent amino acid derivative dansyl-L-phenylalanine as analyte. The fluorescence was collected either externally at the tip level by an optical fiber connected to a spectrofluorimeter or by collection of the fluorescent signal re-emitted into the fiber through the second arm of a Y-shaped bifurcated fiber. The fluorescent analyte could be detected in the low nM concentrations. In order to monitor nonfluorescent analytes, a naphthalimide-based fluorescent monomer was incorporated into the MIP during its synthesis; fluorescence enhancement was observed when analyte binding occurs. Using this system, the sensor containing a MIP specific for the herbicide 2,4-dichlorophenoxyacetic acid (2,4-D), could detect and quantify this analyte at concentrations as low as 2.5 nM. The signaling MIP-based sensor was also applied to analytes of interest for food safety and biomedical applications, such as the mycotoxin citrinin and the sphingolipid, D-erythro-sphingosine-1-phosphate. In the second part of the thesis (Chapter 3), a different type of fiber optic sensor: cheap, fast and made for “single-use”, was developed by using 4-cm long disposable polystyrene evanescent wave optical fiber waveguides. The coating of the MIP was either performed ex-situ, by dip-coating the fiber in a suspension of MIP particles synthesized beforehand, or in-situ by evanescent-wave photopolymerization directly on the fiber. The resulting fiber optic sensor could detect 2,4-D in the low nM range and demonstrated specific and selective recognition of the herbicide over its structural analogues and other non-related carboxyl-containing analytes. Additionally, we demonstrated the versatility of the system by applying the evanescent wave fiber optic sensor to detect citrinin, a mycotoxin, by simply coating the waveguide with a MIP specific for citrinin. This type of technology could possibly be extended to detect other carboxyl-containing analytes, as long as a specific MIP for the concerned analyte is available. In parallel, the technique of evanescent-wave photopolymerization was used for the synthesis of signaling MIP microdots on continuous and nanostructured gold films. This study lays the foundations for future development of plasmonic MIP nanosensors and microchips. In the last part of the thesis (Chapter 4), an innovative sensing method, based on the use of MIPs and analysis by fluorescence polarization, was developed in order to allow the fast and directquantification of analytes in food and environmental samples.
6

Développement d'architectures innovantes associant capteurs acoustiques et matériaux polymères à empreintes moléculaires pour la détection de biomarqueurs de cancer / Association of a Love wave sensor to molecularly imprinted polymer for real time detection of colorectal cancer biomarkers

Lebal, Naîma 14 December 2015 (has links)
Les chiffres des statistiques du cancer colorectal en France et dans le mondemontrent la nécessité de développement de plateformes technologiques plus rapides,sensibles et spécifiques pour assurer le diagnostic du cancer. Un diagnostic rapide va ainsiaider à améliorer l’état de santé et réduire le temps d’attente des résultats qui peut être ungrand facteur de stress pour les patients. L’analyse des biomarqueurs dans le sang, lesurines et autres fluides corporels est l’une des méthodes appliquées pour la détectionprécoce de la maladie. Dans le cadre de ce projet des nucléosides urinaires ont été identifiéscomme biomarqueurs pour le cancer colorectal. Financée par l’Agence Nationale de laRecherche (ANR), à travers le projet CancerSensor (programme TECSAN), cette thèse s’estdéroulée au sein de l’équipe MDA (Microsystèmes de Détection Acoustique) du laboratoireIMS. Dans le cadre de ce projet, nous avons proposé une solution technologique dedétection et de suivi de biomarqueurs du cancer colorectal. Notre choix de la stratégie dedétection s’est porté sur les polymères à empreintes moléculaires comme élément dereconnaissance des biomarqueurs. Celui-ci sera associé à un transducteur acoustique àondes de Love mis au point lors de travaux précédents au sein de l’équipe MDA. Lebiocapteur ainsi développé va cibler les nucléosides mis en évidence pour le cancercolorectal. / Colorectal cancer statistics in France and all over the world demonstrate theneed for fast, sensitive and specific technological platforms development for cancerdiagnosis. A rapid diagnosis will improve the patients’ health status and reduce the resultswaiting time which could be a great stress factor. Biomarkers analysis in blood, urine andother body fluids is recognized as one of the applied methods for early cancer detection. Inframe of this project, urinary nucleosides have been identified as colorectal cancerbiomarkers. Funded by the National Research Agency (ANR), through the cancer sensorproject (TECSAN program), this thesis was carried out in IMS laboratory. Hence, a colorectalcancer biomarkers detection and monitoring technological solution has been proposed. Inour detection strategy, Molecularly Imprinted Polymers (MIP) has been identified asbiomarker recognition element. The MIP layer has been associated to Love Wave acoustictransducer. This biosensor will sense the identified colorectal cancer nucleosides.
7

Development of molecularly imprinted polymers for the recognition of urinary nucleoside cancer biomarkers / Développement de polymères à empreintes moléculaires pour la reconnaissance de biomarqueurs nucléosidiques urinaires du cancer

Krstulja, Aleksandra 27 February 2015 (has links)
Ce rapport de thèse présente l’étude de la technologie des empreintes moléculaires pour le développement de polymères spécifiques et sélectifs envers des biomarqueurs urinaires nucléosidiques du cancer colorectal chez l’Homme. L’objectif principal était de développer des polymères à empreintes moléculaires compatibles aux milieux aqueux en utilisant la technique du « dummy template », l’approche non-covalente and la polymérisation radicalaire en masse. Nous nous sommes concentrés principalement sur la qualité des polymères à partir de leur formulation, c’est-à-dire la spécificité et la sélectivité. Cela a été mené de façon empirique d’abord par la production de poudres issues de polymères monolithiques. Ainsi, pour atteindre les objectifs fixés, nous avons exploré le choix de la molécule « template ». Une étude de modèle est présentée au chapitre 3, en utilisant trois nucléosides 2’,3’,5’-peracétylés comme molécule empreinte dans une approche « dummy template ». Ensuite, en s’appuyant sur la connaissance apportée par le chapitre 3, nous avons développé des polymères à empreintes moléculaires (MIPs) sélectifs de la pseudouridine et de la N7-méthylguanosine dans les chapitres 4 et 5, respectivement, en utilisant la 2’,3’,5’-tri-O-acétylpseudouridine et la 2’,3’,5’-tri-O-acétylguanosine comme templates. L’étude de la rétention des nucléosides recherchés et de leurs analogues structuraux menée par chromatographie en phase liquide et par analyse frontale a permis de déterminer la capacité des différents polymères et de connaître leur comportement dans de l’urine synthétique. Finalement, pour évaluer la possible application de ces polymères dans un échantillon réel, l’urine humaine, la technique de l’extraction sur phase solide à empreintes moléculaires ou MISPE a été développée. Ainsi, une purification sélective des biomarqueurs cibles, tels que la pseudouridine et la N7-méthylguanosine, dans des échantillons d’urines a pu être démontrée. / This thesis report presents the exploration of molecularly imprinted polymer (MIP) technology for developing of a sensitive and selective polymers used in urinary nucleoside biomarker recognition. The main goal was to develop water compatible MIPs prepared by a “dummy template” imprinting technology, using a non-covalent approach and radical-polymerization in bulk. We were focusing mostly on the polymer quality in the formulation (rigidity, stability and repeatability). This was chosen empirically first by production of powders from monolithic MIP. Thus, to accomplish the stated goals, we have explored the choice of the template molecule. A model study presented by Chapter 3, using three 2’3’5’-tri-Operacylateduridine nucleosides as templates in a “dummy” template approach was first developed. Then, applying the knowledge of the type of template choice, we developed a selective MIP for recognition of pseudouridine and N7-methylguanosine in the studies presented in Chapter 4 and Chapter 5 respectively. By using 2’3’5’-tri-O-acetylpseudouridine and 2’3’5’-tri-O-acetylguanosine as templates. Chromatographic methods like HPLC retention and frontal analysis were used in the interest of determining the binding capacity of synthesized polymers, and the behavior in synthetic urine. Finally, to evaluate the possible application of these polymers in urine, molecularly imprinted solid phase extraction (MISPE) was developed. Selective purification of urine samples containing pseudouridine and N7-methylguanosine obtained in the end.
8

Conception et réalisation de capteurs biomimétiques à base de polymères à empreintes moléculaires à transduction électrochimique / Design and implementation of biomimetic electrochemical sensors transduction based on molecularly imprinted polymers

Betatache, Amina 13 December 2013 (has links)
Les biocapteurs sont des moyens d'analyse en plein essor à la fois rapides, sélectifs et peu coûteux, applicables à des domaines très variés (environnement, santé, agroalimentaire…). La capacité de reconnaissance moléculaire extraordinaire de biomolécules telles que les enzymes ou les anticorps a été exploitée avec succès pour la réalisation de nombreux biocapteurs. Cependant, l'inconvénient majeur de ces récepteurs biologiques est qu'ils sont difficiles à produire et fragiles. Une manière de surmonter ces inconvénients consiste à les remplacer par des récepteurs artificiels présentant des propriétés de reconnaissance similaires. Parmi les matériaux biomimétiques prometteurs figurent les polymères à empreintes moléculaires (MIPs). Dans ce travail, nous nous sommes intéressés au développement de deux capteurs biomimétiques impédimétriques, le premier basé sur l'utilisation de poly(éthylène co-alcool vinylique) imprimé pour la détection de la créatinine et le deuxième sur des MIPs de polyméthacrylate pour la détection de la testostérone. Dans le premier cas, le polymère imprimé a été produit et déposé à la surface d'électrodes en or, soit par drop-coating, soit sous forme de nanofibres par la technique d'électrofilage. Dans le deuxième, le MIP a été synthétisé par polymérisation radicalaire de l'acide méthacrylique en présence d'éthylèneglycol diméthacrylate (réticulant), d'initiateur et de testostérone en utilisant la méthode du « grafting from » qui consiste à greffer d'abord l'initiateur sur la surface du transducteur mais pour la polymérisation on a utilisé deux approches (spin-coating d'une solution de prépolymérisation sur la surface du transducteur ou l'immersion de ce dernier dans la solution de monomère plus testostérone) suivie de l'exposition à une source d'energie pour effectuer la polymérisation. Les performances des capteurs (limite de détection, sélectivité, reproductibilité) ont ensuite été évaluées / Biosensors are rapid, selective and low-cost analytical devices of growing interest for a wide range of application fields (e.g. environment, food, health). The extraordinary molecular recognition capabilities of sensing biomolecules such as enzymes and antibodies have been successfully exploited in the elaboration of a number of biosensors. However, these biorecognition elements are often produced via complex and costful protocols and require specific handling conditions because of their poor stability. To circumvent these limitations, artificial receptors of similar recognition properties are now proposed as alternatives to natural receptors in sensor technology. Molecular imprinted polymers are among the most promising biomimetic materials reported. In this work, we developed two impedimetric biomimetic sensors. The first one is based on imprinted poly(ethylene co-vinyl alcohol) for creatinine detection and the second on polymethacrylate MIPs for testosterone analysis. In the first case, MIP was produced and deposited onto gold microelectrodes, either by spin-coating of a pre-polymerization solution, or by electrospinning. In the second case, MIPs were synthetized by photopolymerization of methacrylic acid in presence of ethyleneglycoldimethacrylate (cross-linker), an azo-initiator and testosterone as template using the “grafting from” method in which the initiator is first attached to the transducer surface but to effect polymerization we used two different approaches (dip-coating of a prepolymerization solution on the transducer surface functionalized with the initiator or immersing it in the solution of monomers and testosterone) followed by exposure to an energy source to effect polymerization. Then, analytical performances (linear range, detection limit, selectivity and reproducibility) of both creatinine and testosterone sensors were determined and compared
9

Mise au point d'un microsystème électrophorétique pour l'analyse des hydrocarbures aromatiques polycycliques dans les huiles alimentaires / Development of a capillary electrophoresis microchip for polycyclic aromatic hydrocarbons analysis in edible oils

Ferey, Ludivine 31 October 2013 (has links)
Les hydrocarbures aromatiques polycycliques (HAP) sont des contaminants de notre environnement et de notre alimentation. En raison de leur toxicité, la Commission européenne a réglementé leur teneur dans les denrées alimentaires et notamment dans les huiles. Les industriels des corps gras ont donc pour obligation de vérifier la conformité de leurs produits. Dans ce contexte, le groupe Lesieur souhaiterait développer un nouvel outil analytique rapide et portable. Ainsi, ce vaste projet de recherche vise à concevoir un microsystème électrophorétique capable d'analyser les HAP dans les huiles alimentaires. Première étude à s'inscrire dans ce projet, ce travail de thèse a donc consisté à développer de nouveaux protocoles analytiques. Dans une première partie, des méthodes de séparation des HAP ont été développées en électrophorèse capillaire (CE) modifiée par des cyclodextrines couplée à un détecteur de fluorescence induite par laser. En suivant des stratégies multivariées basées sur les plans d'expériences, deux méthodes de séparation ont été optimisées. Les huit HAP communs aux listes établies par l'agence de protection de l'environnement des Etats-Unis et l'agence européenne de sécurité sanitaire des aliments ont été séparés en moins de 7 min et dix-neuf HAP, également classés par ces deux organismes, ont été analysés en moins de 18 min. Ces méthodes de séparation ont été appliquées avec succès à des extraits d'huile dopés. Dans une deuxième partie, il a été question de transférer la méthode d'analyse des huit HAP au format microsystèmes. La principale difficulté rencontrée a été le manque de sensibilité du système de détection couplé aux puces. Le premier objectif a donc été d'optimiser les quantités d'échantillon injectées et les paramètres de la détection avec un composé modèle dans un tampon borate. Cependant, seulement quatre HAP sur les dix-neuf étudiés précédemment en CE ont pu être détectés. Toutefois, dans les conditions optimisées par le plan d'expériences, ils étaient séparés en moins de 4 min. Enfin, différents polymères à empreintes moléculaires (MIP) ont été synthétisés en vue d'extraire sélectivement les HAP des huiles. Après un criblage des conditions de synthèse, la sélectivité de chaque MIP a été évaluée en milieu pur en comparant sa capacité de rétention avec celle d'un polymère non-imprimé. Les huit HAP communs aux deux listes ont finalement pu être extraits sélectivement à partir d'huiles de tournesol, mais avec des rendements d'extraction encore insuffisants et qui nécessitent une amélioration de la procédure d'extraction. / Polycyclic aromatic hydrocarbons (PAHs) are widespread contaminants in the environment and food products. Given their toxicity, their concentrations are regulated by the European Commission in food products and especially in edible oils. Consequently, manufacturers of fat products have to verify the conformity of their products. In this context, Lesieur wants to develop a rapid and portable new analytical tool. Hence, this ambitious research project aims at developing a capillary electrophoresis microchip for PAH analysis in edible oils. This PhD study, first one involved in this project, consisted in developing new analytical protocols.In a first part, PAH separation methods were developed by cyclodextrin-modified capillary electrophoresis (CE) with laser-induced fluorescence detection. Using experimental design-based strategies, two separation methods were optimized. The 8 PAHs in common between the United States Environmental Protection Agency and the European Food Safety Authority lists of priority pollutants were separated in less than 7 min, while 19 PAHs, also targeted by these institutions, were separated in less than 18 min. These CE separation methods were successfully applied to the analysis of spiked edible oil extracts.The second part aimed at transferring the electrophoretic separation method of the 8 PAHs from the capillary to the microsystem format. The lack of sensitivity of the detection system hyphenated with chips was the main difficulty encountered. Thus, injected sample amounts and detection parameters were first optimized with a model compound in a borate buffer. However, only 4 out of the 19 PAHs, previously studied in CE, could be detected. Nevertheless, under conditions predicted by the design of experiments, they were baseline resolved in less than 4 min.Finally, several molecularly imprinted polymers (MIPs) were synthesized for the selective extraction of PAHs from oils. After a screening of synthesis conditions, the selectivity of each MIP was evaluated in pure media by comparing the extraction recoveries obtained on MIP with those obtained on a non-imprinted polymer. Finally, the 8 PAHs in common between the two lists were selectively extracted from sunflower oils, but with low recoveries. Improvements in extraction procedures are still required.
10

Elaboration of a new sensor based on molecularly imprinted polymers for the detection of molecules in physiological fluids / Elaboration de polymères à empreinte moléculaire pour la détection optique de molécule dans un fluide physiologique

Marie, Héléne 19 December 2013 (has links)
Ce travail de thèse avait pour objectif l'élaboration d'un capteur optique pour la détection directe de molécules d'intérêt dans un fluide biologique. Deux stéroïdes et un xéniobiotique (herbicide) ont été choisis en tant que biomarqueurs apparaissant dans des fluides corporels : respectivement l'acétate de cyprotérone, le cortisol et l'acide 2,4 dichlorophénoxyacétique. La partie détection, d'une part, est assurée par les polymères à empreintes moléculaires (MIPs, de l'anglais Molecularly Imprinted Polymers). Ces récepteurs synthétiques sur mesure présentent en effet de nombreuses qualités pour l'intégration dans un capteur. Des polymères à empreintes moléculaires ont ainsi été développés pour les analytes visés. L'optimisation des formulations de polymère a été basée sur des plans d'expériences. La transduction optique, d'autre part, est basée sur la structuration du polymère sous la forme d'un cristal photonique. Des opales ont été fabriquées avec un procédé industrialisable pour permettre la mise en forme du MIP en opale inverse. Ainsi structuré à l'échelle submicronique, le matériau présente une couleur susceptible d'évoluer lors de la détection de l'analyte, et ce, grâce à un changement de conformation (gonflement). Les formulations polymères étudiées ont généré des gonflements réduits mais visibles en spectrophotométrie. Le travail rapporté dans cette thèse consiste donc en l'élaboration de polymères à empreintes moléculaires et leur intégration dans un capteur afin de détecter un analyte de façon directe, rapide et ne nécessitant que des équipements transportables, voire portables. / This thesis aimed at elaborating an optical sensor to detect molecules in a biological fluid. Two steroids and a xenobiotic were identified as biomarkers released in some body fluids: cyproterone acetate, cortisol and 2,4-dichlorophenoxyacetic acid respectively. On one hand, detection was performed by Molecularly Imprinted Polymers (MIPs). These tailor-made synthetic receptors display numerous qualities that foster their integration in sensors. MIPs were therefore developed against the targeted analytes. Formulation optimization was led thanks to experimental designs. On the other hand, optical transduction was made possible thanks to the structuring of a polymer into a photonic crystal. Opals were manufactured with a new process suitable for large scales and were used to mold MIPs in inverse opals. Thus, submicron structures of the polymer are responsible for the color of the sensor. A change of color is triggered by the recognition of the analyte by the polymer (upon swelling). Polymers studied displayed sufficient swelling observed by spectrophotometry. Finally, the work of this thesis consisted in elaborating polymer formulations and their integration in a sensor so as to detect an analyte with direct, rapid and unobtrusive means.

Page generated in 0.1098 seconds