• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5094
  • 268
  • 187
  • 186
  • 185
  • 185
  • 157
  • 157
  • 101
  • 96
  • 54
  • 29
  • 28
  • 9
  • 7
  • Tagged with
  • 5468
  • 1954
  • 1942
  • 1564
  • 784
  • 667
  • 607
  • 530
  • 523
  • 492
  • 474
  • 415
  • 350
  • 349
  • 313
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
131

Avaliação "in vitro" da resistência à abrasão de resinas compostas comerciais à base de dimetacrilato e uma à base de silorano fotoativadas com duas densidades de energia

Barbieri, Guilherme Machado January 2009 (has links)
Made available in DSpace on 2011-12-27T14:14:13Z (GMT). No. of bitstreams: 2 000411472-0.pdf: 3421246 bytes, checksum: 2de63642b6d6b46a8c8709c79bb57f6a (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / Article 1 - Aims: To compare the surface roughness of four resin composites with different organic matrix compositions applying the abrasion testing by tooth brushing until 20,000 cycles. Methods and materials: One hundred and sixty samples were buildup and divided into 16 groups (n=10) according to the type of composite resin, source of light and energy density. The resin composites used were Charisma, Z250, ROK and Filtek LS, being photo activated with LED or halogen unit, receiving 8 or 16 J/cm2. After 24h, the samples were submitted to a simulated wear test with a dentifrice and a soft toothbrush by periods of 6 months (5000 cycles), 12 months (10. 000 cycles) e 24 months (20. 000 cycles). After each period was realized the surface roughness measurement. Results: The factors as energy density (p=0. 0001), source of light (p=0. 0047), resin composites (p=0. 0001) and cycles (p=0. 0001) influenced the results. The mean roughness values obtained were (means followed by the same letter are not significantly different according to Tukey (α=5%)): 0. 07μm (A) - ROK; 0. 08μm (B) - Z250; 0. 12μm (C) - Charisma; 0,17μm (D) - Filtek LS. Conclusion: The UDMA-based resin composites present higher surface abrasion resistance. The silorane-based composites present lower surface abrasion resistance. The resin composites photo activated by 16J/cm2 present lower roughness than composites cured by 8J/cm2.Article 2 - Aim: To evaluate the surface roughness of two resin composites with different organic phase when submitted to a simulated wear test with tooth brushing and whitening dentifrices. Materials and methods: Forty-eight samples were built and divided into 6 groups (n=8) according to composite resin (ROK (SDI) or Z250 (3MESPE) and dentifrice used (Colgate Total 12, Colgate Max White or Close up Extra Whitening). The resins were submitted to cycles of simulated tooth brushing until 24 months. After each simulated period, the surface roughness of the resins was measured. Results: The surface roughness(Ra) average, in μm, to the Colgate total 12 (control), Colgate Max White and Close up Extra Whitening dentifrices were, respectively (means followed by the same letter are not statistically different to ANOVA and Tukey (p<0,05)): 1) ROK: 0. 09(B), 0. 12(B) and 0. 11(B); 2) Z250: 0. 09(B), 0. 21(A) and 0. 21(A). Conclusions: The ROK composite resin presented lower surface roughness (0. 11) than Z250 (0. 17). The resin composites ROK and Z250 have its abrasion resistance decreased when the whitening dentifrices Colgate Max-White and Close Up Extra-Whitening are applied. / Artigo 1 - Objetivo: Comparar a rugosidade de superfície de quatro resinas compostas com diferentes composições de matriz orgânica, através do ensaio de abrasão por escovação simulada até 20. 000 ciclos. Materiais e Métodos: Cento e sessenta corpos de prova foram confeccionados e divididos em 16 grupos (n=10) conforme o tipo de resina, fonte de luz e quantidade de energia. As resinas utilizadas foram Charisma, Z250, ROK e Filtek LS, sendo fotopolimerizadas com LED ou Luz halógena, recebendo 8 ou 16 J/cm². Após 24 horas, os corpos de prova foram submetidos à escovação simulada com dentifrício e escova macia por períodos de tempo equivalentes à 6 meses (5000 ciclos), 12 meses (10. 000 ciclos) e 24 meses (20. 000 ciclos). Após cada período foi realizada a medição da rugosidade de superfície. Resultados: Fatores como energia (p=0,0001), tipo de fonte (p=0,0047), resinas (p=0,0001) e ciclo (p=0,0001) influenciaram nos resultados obtidos. Os valores de rugosidade média obtidos foram (médias seguidas de mesma letra não apresentam diferença estística para Tukey (α=5%): 0,07μm (A) para ROK; 0,08µm (B) para Z250; 0,12μm (C) para Charisma e 0,17μm (D) para filtek LS. Conclusão: as resinas compostas que contém UDMA apresentam maior resistência à abrasão de superfície; resinas baseadas em Siloranos apresentam a menor resistência ao desgaste por abrasão e resinas compostas fotoativadas com 16J/cm² apresentam menor rugosidade de superfície do que as polimerizadas com 8J/cm².Artigo 2 - Objetivos: O objetivo deste estudo foi comparar a rugosidade de superfície de duas resinas compostas, com diferentes composições orgânicas, quando submetidas ao ensaio de abrasão por escovação com dentifrícios clareadores. Materiais e métodos: Quarenta e oito corpos-de-prova foram confeccionados, divididos em 6 grupos (n=8) conforme tipo de resina e dentifrício utilizado. As resinas foram submetidas a ciclos de escovação os quais simularam até 24 meses. Após cada período simulado, as resinas compostas tiveram a rugosidade de superfície mensurada. Resultados: as médias finais de rugosidade de superfície (Ra), em μm, para os dentifrícios Colgate total 12 (controle), Colgate Max White e Close up Extra Whitening foram, respectivamente (médias seguidas de mesma letra não apresentam diferença estatística significante para ANOVA e Tukey (p<0,05)): 0,09 (B), 0,12 (B) e 0,11 (B) para a resina ROK; e 0,09 (B), 0,21 (A) e 0,21(A) para Z250. Conclusões: A resina composta ROK apresentou menor rugosidade de superfície do que a resina Z250. As resinas compostas ROK e Z250 tem a sua resistência ao desgaste superficial diminuída com o uso de dentifrícios mais abrasivos e utilizados para clareamento dos dentes: Colgate Max-White e Close Up Extra-Whitening.
132

Análise do tempo e da fluência da LLLT no processo de reparo de feridas em dorso de ratos

Poli, Vladimir Dourado January 2010 (has links)
Made available in DSpace on 2011-12-27T14:14:18Z (GMT). No. of bitstreams: 2 000425869-0.pdf: 4399384 bytes, checksum: 3e433ccca5e1acd4bbb191c1f4293ca1 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / This study aimed to compare the effects of different fluencies of indiumgallium- aluminum phosphide laser (λ= 685 nm) on skin wound healing in rats. Thirty six male rats were used, divided in three groups of 12 animals each. Two standardized skin wounds were created on the back of each animal, one treated with laser and the other serving as control. In group 1, the irradiations were performed with a dosimetry equivalent to average doses used in most recent polls, determined as 8 J/cm2. The second group was irradiated with twice the dose of energy (16 J/cm2) and group 3 with half the dose (4 J/cm2). The irradiations were performed immediately after surgery, in 48 hours, on 4 and 7 days, and the animals were killed at 4, 7 and 9 days. Therefore, each animal received, depending on his death, two, three or four irradiations. The healing tissues were excised and analyzed with optical microscopy. Histomorphometric analysis was performed, considering the measures between the epithelial edges, and histomorphological analysis. Using the paired ttest, there was a significant difference (p = 0. 004) between values referring to the average of the measures between the test and control samples. When analyzing the energy doses used (4, 8 and 16 J/cm2) and time of observation of the animals (4, 7 and 9 days), it appears that there was no difference in the fluency factor, but it occurred on the time factor, with changes most evident in the early stages (4 days) of the healing process. Based on histomorphologic and histomorphometric analysis, this study demonstrated that the Low Level Laser Therapy (LLLT) increases the rate of wound healing in rats when irradiated with indium-gallium-aluminum phosphide laser (λ = 685 nm). There are no differences between fluencies used (4, 8 and 16 J/cm2), but the time factor seems to be relevant, with changes most evident in the early stages of the healing. / O presente estudo teve como propósito comparar, em diferentes tempos, diferentes fluências do laser vermelho de fosfeto de índio-gálio-alumínio (λ=685 nm) sobre o processo de cicatrização de feridas cutâneas padronizadas em dorso de ratos. Foram realizadas duas feridas cirúrgicas em 36 ratos, sendo uma tratada com laser e a outra servindo como controle. Os ratos foram divididos em três grupos. No grupo um, as irradiações foram realizadas com dosimetria equivalente a média das doses mais utilizadas nas pesquisas recentes, determinada como 8 J/cm2. O grupo dois foi irradiado com o dobro da dose de energia, ou seja, 16 J/cm2, e o grupo três com metade da dose, ou 4 J/cm2. As irradiações foram realizadas imediatamente após o término da cirurgia, em 48 horas, em quatro e sete dias, e os animais foram mortos aos quatro, sete e nove dias. Portanto, cada animal recebeu, na dependência de sua morte, duas, três ou quatro irradiações. As lesões foram excisadas e analisadas em microscopia óptica. Foram realizadas análises histomorfométricas, considerando as medidas entre as bordas epiteliais, e análises histomorfológicas. Verificou-se, utilizando-se o teste t pareado, que houve diferença significativa (p = 0,004) entre os valores referentes às médias das medidas entre as amostras teste e controle. Ao se analisar as doses de energia utilizadas (4, 8 e 16 J/cm2) e o tempo de observação dos animais (quatro, sete e nove dias), verifica-se que não houve diferença em relação ao fator fluência, mas ocorreu quanto ao fator tempo, sendo as alterações mais evidentes nos momentos iniciais (quatro dias) do processo de reparo.A partir das análises histomorfométrica e histomorfológica, este estudo demonstrou que a terapia a laser em baixa intensidade (LLLT) aumenta a velocidade de cicatrização em ferimentos produzidos em dorso de ratos quando irradiados com o laser de fosfeto de índiogálio- aluminio (λ = 685 nm). Não há diferenças entre as doses de energia utilizadas (4, 8 e 16 J/cm2), mas há em relação ao fator tempo, sendo as alterações evidenciadas nos momentos iniciais da cicatrização.
133

Análise de metodologias de microdureza aplicadas a compósitos: é possível comparar resultados utilizando-se diferentes protocolos?

Barbosa, Gustavo Frainer January 2010 (has links)
Made available in DSpace on 2011-12-27T14:14:20Z (GMT). No. of bitstreams: 2 000427785-0.pdf: 701572 bytes, checksum: 6d68289fb0a8c4a345e9c231cfaa8675 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / Objective: Firstly, to evaluate correlation between load and dwell time in composite resin microhardness tests, using Vickers and Knoop mechanic test methods. Secondly, to correlate time and load on Knoop microhardness test over a composite resin, and to show, with the obtained results, whether composite resin conversion degree comparison is possible through the tests. Materials and Methods: Resin Grandio (Voco, Cuxhaven, Germany), shade A2, was used to make the samples. Ninety (90) samples were made on a six-(6)-mm-diameter by three-(3)-mm-deep polytetrafluorethylene matrix, where two equidistant increments were each photocured for 20s by the LED device (Celalux, Voco, Cuxhaven, Germany, with 800 mW/cm2). The samples were randomly divided into three groups according to the load factor. Groups I, II and III received loads at 50g, 100g and 500g respectively. These groups were divided into nine subgroups according to the deal time (15s, 30s, 45s). Each sample received indentations from a Shimadzu HMV tester (Shimadzu, Kyoto, Japan). The results were submitted to a two-way ANOVA with fixed factors (load and dwell time), and to the post-hoc Tukey multiple comparison test at α = 0. 05.Results: Significant differences were recorded between groups for each methodology, Vickers and Knoop (p<0. 001). Among the Vickers (VHN) tested samples, the average recorded ranged from 164. 94 (50g for 45s) to 210. 33 (100g for 45s). Knoop microhardness (KHN) ranged from 128. 92 (500g 45s) to 184. 26 (100g 15s). For both methodologies, both load and dwell time were statistically significant (p<0. 001), this way showing that different loads and dwell time influence the microhardness of resins. Conclusion: Firstly, this study demonstrated that correlating both Vickers and Knoop microhardness test results is not recommended, and similar protocols must be applied to allow comparisons among the different studies that use the same kind of test. Secondly, this study demonstrated that Knoop microhardness test results is not recommended for composite resin conversion degree comparisons, and similar protocols should be applied to allow this kind of correlation. / OBJETIVO: Primeiramente, avaliar, em uma resina composta, a correlação existente, em testes de microdureza, entre os fatores carga e tempo de aplicação, utilizando-se os métodos de ensaio mecânico Vickers e Knoop. Em segundo lugar, avaliar, em uma resina composta, os fatores carga e tempo de aplicação no teste de microdureza Knoop, e mostrar, com os resultados obtidos, quando é possível, através dos testes, fazer uma comparação com o grau de conversão da resina composta. MATERIAIS E MÉTODOS: Resina Grandio (Voco, Cuxhaven, Alemanha), cor A2, foi utilizada para confeccionar as amostras. Noventa (90) amostras foram feitas em uma matriz de politetrafluoretileno com seis (6) mm de diâmetro por três (3) mm de profundidade, onde dois incrementos equidistantes foram fotopolimerizados por 20s cada um através de um dispositivo LED (Celalux, Voco, Cuxhaven, Alemanha, com 800 mW/cm2). As amostras foram divididas aleatoriamente em três grupos de acordo com o fator carga. Os grupos I, II e III receberam cargas de 50g, 100g e 500g, respectivamente. Estes grupos foram divididos em nove subgrupos de acordo com o fator tempo de aplicação (15s, 30s, 45s). Cada amostra recebeu edentações de um dispositivo Shimadzu HMV tester (Shimadzu, Kioto, Japão). Os resultados foram analisados estatisticamente através de ANOVA com fatores fixos (carga e tempo de aplicação), e ao teste de comparações múltiplas de Tukey (α = 0. 05).RESULTADOS: Diferenças significativas foram encontradas entre os grupos para cada metodologia, Vickers e Knoop (p<0. 001). Entre as amostras testadas com a metodologia Vickers (VHN), a média encontrada variou de 164. 94 (50g 45s) até 210. 33 (100g 45s). Os valores de microdureza para a metodologia Knoop (KHN) variaram de 128. 92 (500g 45s) até 184. 26 (100g 15s). Para ambas as metodologias, tanto o fator tempo e o fator tempo de aplicação foram estatisticamente significantes (p<0. 001), isto mostra que diferentes cargas e tempos de aplicação influenciam na microdureza das resinas. CONCLUSÃO: Primeiramente, este estudo demonstrou que correlacionar os resultados de testes de microdureza Vickers and Knoop não é recomendado, e protocolos similares devem ser aplicados a fim de permitir comparações entre diferentes estudos que utilizam o mesmo tipo de teste. Em Segundo lugar, este estudo demonstrou que os resultados de microdureza Knoop não são recomendados para comparações com o grau de conversão das resinas compostas, e protocolos similares devem ser aplicados a fim de permitir este tipo de correlação.
134

Resistência de união de pinos intrarradiculares cimentados à dentina com e sem tratamento com laser de Nd:YAG

Simon, Rosana Simões January 2009 (has links)
Made available in DSpace on 2011-12-27T14:14:20Z (GMT). No. of bitstreams: 2 000425443-0.pdf: 137763 bytes, checksum: 07c751d4d7073c523bf8aaedf5f3b302 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / Aims: to evaluate the bond strength of fibre-posts luted with two kind of resin cements to dentin of the root canal treated or not with Nd:YAG laser associated to phosphoric acid. Materials and methods: Sixty one-root teeth with similar morphology and length were submitted to the endodontic treatment with manual instrumentation. After, it were divided into six groups according to the luting protocol of the fibre post (n=10): G1 –RelyX Unicem; G2 – Nd:YAG laser + self-etching luting cement RelyX Unicem; G3 – 37% phosphoric acid gel (AG37%) + RelyX ARC; G4 – Nd:YAG laser + AG37% + RelyX ARC; G5 – etching with the Experimental Solution (ES): Patent number BRPI0903355-6) + RelyX ARC; e G6 – Nd:YAG laser + SS solution + RelyX ARC. The Nd:YAG laser were irradiated with the following protocol: 1064 nm, 60 mJ, 15 Hz and 47. 77 mJ/cm2, 1 min. Afterwards, the teeth with the luted fibre posts were stored in distilled water at 37ºC for 1 week. Next, the roots were sectioned in thirds – cervical, medial and apical – being the slices submitted to the push-out bond strength test. Results: the SS solution group associated to RelyX ARC presented together with the Nd:YAG laser associated to the RelyX Unicem the higher bond strength considering all thirds. Notwithstanding, the phosphoric acid gel associated to the RelyX ARC presented the lower bond strength together with the Relyx Unicem control group. Conclusion: The use of the ES solution increased significantly the bond strength of the RelyX Arc to dentin of the root canal. / Objetivos: Avaliar a resistência de união de pinos de fibra de vidro cimentados à dentina radicular tratada com laser de Nd:YAG, ácido fosfórico gel a 37% ou com uma solução experimental (PATENTE solicitada ao INPI nº PI0903355-6), utilizando dois tipos de cimentos resinosos. Materiais e métodos: Sessenta dentes unirradiculares com morfologia e comprimentos semelhantes foram submetidos ao tratamento endodôntico tradicional ou com laser de Nd:YAG, com instrumentação manual. Após, os dentes foram divididos em seis grupos de acordo com o protocolo de cimentação do pino de fibra de vidro (n=10): G1 –RelyX Unicem; G2 –laser Nd:YAG + RelyX Unicem; G3 –ácido fosfórico gel a 37% (AG37%) + RelyX ARC; G4 –laser Nd:YAG + AG37% + RelyX ARC; G5 – condicionamento com solução experimental (PATENTE solicitada ao INPI nº PI0903355- 6) + RelyX ARC; e G6 – laser Nd:YAG + solução experimental (PATENTE solicitada ao INPI nº PI0903355-6) + RelyX ARC. O laser de Nd:YAG foi irradiado com o seguinte protocolo: 1064 nm, 60 mJ, 15 Hz, 47,77 mJ/cm2 durante 1 min. Os dentes com os pinos cimentados foram armazenados em água destilada a 37ºC por 7 dias. Após esse período, as raízes foram seccionadas em terços cervical, médio e apical, sendo as fatias submetidas ao ensaio de resistência de união por push-out. Ainda, seis dentes foram submetidos aos tratamentos de superfície e levados à microscopia eletrônica de varredura e análise EDS. Resultados: o grupo da solução experimental (PATENTE solicitada ao INPI nº PI0903355- 6) associada ao cimento resinoso RelyX ARC apresentou juntamente com o grupo do laser 4 de Nd:YAG associado ao cimento RelyX Unicem a maior resistência de união considerando todos os terços radiculares. Por sua vez, o ácido fosfórico gel associado ao cimento RelyX ARC apresentou a menor resistência de união juntamente com o grupo do RelyX Unicem. Conclusão: O uso da solução experimental (PATENTE solicitada ao INPI nº PI0903355-6) aumentou significativamente a resistência de união do cimento resinoso RelyX ARC à superfície dentinária do conduto radicular, assim como a irradiação por laser, de uma maneira geral, também aumentou a resistência de união particularmente nos grupos G2 e G4.
135

Propriedades mecânicas de resinas compostas com nanopartículas

Rosa, Rogério Simões January 2010 (has links)
Made available in DSpace on 2011-12-27T14:14:26Z (GMT). No. of bitstreams: 2 000427363-0.pdf: 529456 bytes, checksum: 061439668cdb3da163cb071f3d708111 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / Introduction: The increasing demands in esthetic dentistry have led to the development of resin composite materials for direct restorations with improved physical and mechanical properties. The latest development in this field has been the introduction of nanoparticles only (nanofilled) or microhybrid and nanomeric particles (nanohybrid) in inorganic matrix. Objective: Evaluate the mechanical behavior of one nanofilled (Filtek Supreme XT - 3M ESPE) and two nanohybrid (Esthet X-Dentsply, Grandio-Voco) composites with enamel and body shades (A2).Background data: The real innovation that implies better mechanical behavior is the nanofiller’s possibility to improve the load of the inorganic phase in 80 Wt% when compared to microfilled composites 50 Wt% for example. Methods: Ten samples of each material were submitted to compressive strength, flexural strength and diametral tensile strength test in an universal testing machine. The flexural modulus test was calculated based on flexural strength results. Ten samples of each group were submitted to knoop microhardness test. One sample of each material were submitted to nanohardness and elasticity modulus. The results were submitted to ANOVA and Tukey statistical tests (α=0. 05). One sample of each group was used in order to register the inorganic weight filler content. Results: An improved mechanical behavior of Grandio was observed for flexural modulus, knoop microhardness, nanohardness, elasticity modulus and weight filler content. For diametral tensile strength Grandio and Filtek Supreme XT obtained higher averages. The tested composite resins ranged similar medias for compressive strength. For flexural strength Filtek Supreme XT and Esthet X showed higher results. Conclusions: The composite resin weight filler content is directly correlated to her mechanical behavior. The filler size and shape of composite resins seemed to be a fine tuning factor for the determination of elasticity modulus. Larger filler sizes tend to render the material stiffer and irregular filler shapes result in higher modulus values. / Introdução: A demanda por odontologia estética conduziu ao desenvolvimento de resinas compostas com melhores propriedades físicas e mecânicas. Em consequência disso, surgiram as resinas compostas que apresentam somente nanopartículas (nanoparticuladas) e as que apresentam partículas nanométricas e microhíbridas (nanohíbridas) em sua matriz inorgânica. Objetivo: Avaliar o comportamento mecânico de uma resina composta nanoparticulada (Filtek Supreme XT - 3M ESPE) e de duas nanohíbridas (Esthet XDentsply, Grandio-Voco) com cores de esmalte e de dentina (A2).Contexto da pesquisa: A grande inovação que gera um melhor comportamento mecânico ao material é a possibilidade de aumentar seu conteúdo em peso de carga inorgânica para 80%, ao passo que as microparticuladas apresentam 50%.Metodologia: Dez amostras de cada resina composta foram submetidas aos testes de resistência à compressão, resistência flexural, resistência à tração diametral numa máquina de ensaio universal. Os dados do teste de módulo flexural foram obtidos a partir dos resultados de resistência flexural. Dez amostras de cada resina composta foram submetidas ao teste de microdureza knoop. Uma amostra de cada material foi submetida aos testes de nanodureza e de módulo de elasticidade. Os resultados foram analisados estatisticamente através de ANOVA e de teste de Tukey (α=0,05). Uma amostra de cada resina composta foi utilizada para registrar seu conteúdo em peso de carga. Resultados: Após a análise estatística das médias, observou-se que a resina composta Grandio apresentou melhor comportamento mecânico para os testes de módulo flexural, microdureza knoop, nanodureza, módulo de elasticidade e conteúdo em peso de carga. No que tange à resistência à tração diametral, Grandio e Filtek Supreme XT obtiveram as maiores médias. As três resinas compostas testadas atingiram médias similares estatisticamente para resistência à compressão. No que se refere à resistência flexural, Filtek Supreme XT e Esthet X apresentaram as maiores médias. Conclusões: O conteúdo de carga em peso das resinas compostas tem relação direta com suas propriedades mecânicas. O tamanho e a forma das partículas de carga tendem a influenciar no módulo de elasticidade. Partículas maiores tendem a dar mais resistência ao material e as de formatos irregulares tornam o material com maiores valores de módulo de elasticidade.
136

Diferentes tipos de substrato dentinário podem influenciar a resistência de união em cimento resinoso autoadesivo?

Scheid, Patrícia Alves January 2011 (has links)
Made available in DSpace on 2011-12-27T14:14:36Z (GMT). No. of bitstreams: 2 000430602-0.pdf: 3992171 bytes, checksum: dbc119f68b2383c9f1f45cacf8eaf454 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The purpose of this study was evaluated the influence of different dentin substrate on the microtensile bond strength of a self-adhesive resin cement. Fifty human molars were selected, twenty-five teeth with coronal dentin caries and twenty-five teeth with old amalgam restorations. Teeth with dentin caries were ground with #100 silicon carbide paper under running water until the removal carie dentin remaining a caries- affected dentin. Teeth with old amalgam restorations followed the same protocol until the removal restoration exposing a discolored dentin. Teeth without caries-affected or discolored dentin surrounded by sound dentin were discarded. Radiographs were taken of the teeth in order to select those with remaining dentin around 2 to 3 mm. The selected teeth had their roots included in self-cured acrylic resin. Blocks of microhybrid composite resin (Sinfony, 3M ESPE) were made according to the manufacturer´s instructions. Luting procedures with the self-adhesive resin cement (RelyX Unicem, 3M ESPE) were made in moist dentin with the composite resin disc kept with pressure of 0. 8 kg and it was light activated with halogen unit (3M ESPE) for a total of 80 seconds. Bonded specimens were stored in water at 37ºC for 24 hours.The restorations were included in self-cured acrylic resin and they were serially sectioned into sticks. Specimens (n=24) were submitted to microtensile bond strength on a universal testing machine EMIC DL – 2000 at crosshead speed of 0. 5mm/min. Results were evaluated according to Variance Analysis and Tukey test (α=0. 05). The highest bond strength mean was obtained with sound dentin (7. 58±2. 95 MPa). Discolored dentin obtained intermediate bond strength mean (6. 43±4. 46 MPa) without statistically significant differences. Caries-affected dentin showed the lowest bond strength mean (4. 21±3. 1 MPa) differing statistically from sound dentin. Failure mode were examinated with a scanning electron microscope. The predominant failure mode was mixed to the caries-affected dentin (85%) and discolored dentin (100%) whereas sound dentin was adhesive failure (54%). The results suggest that different dentin substrates can affect the bond strength of self- adhesive resin cement RelyX Unicem. / Este trabalho se propôs a avaliar a influência de diferentes substratos dentinários da resistência de união de um cimento resinoso autoadesivo. Foram pré-selecionados 50 molares humanos, sendo 25 contendo restaurações de amálgama e 25 contendo tecido cariado. Os dentes com tecido cariado foram desgastados em politriz com auxílio de lixa de carbeto de sílicio de granulação 100 até a remoção de tecido cariado, expondo uma dentina afetada por cárie. Os dentes contendo restaurações de amálgama seguiram o mesmo protocolo, até a remoção da restauração, expondo uma dentina com alteração de cor. Os dentes que não apresentaram dentina afetada por cárie ou dentina alterada pelo amálgama circundados por dentina hígida foram descartados. Foram realizadas tomadas radiográficas a fim de selecionar os dentes que apresentavam dentina remanescente de 2 a 3 mm. Os dentes selecionados tiveram suas raízes embutidas em resina acrílica autopolimerizável. Foram confeccionadas pastilhas de resina composta microhíbrida (Sinfony, 3M ESPE) conforme as orientações do fabricante. A cimentação com o cimento resinoso autoadesivo RelyX Unicem (3M ESPE) foi realizada em dentina úmida, mantida sob pressão de 0,8 kg e fotopolimerizada com luz halógena (3M ESPE) por um período total de 80 segundos. As amostras foram armazenadas por 24 horas em 100% de umidade a 37ºC. As restaurações foram incluídas com resina acrílica autopolimerizável e submetidas a cortes seriados, obtendo-se o formato de palitos. Os palitos foram examinados e divididos de acordo com o tipo de substrato dentinário que apresentavam: hígido, cariado e alterado por íons provenientes de amálgama. Os espécimes (n=24) foram submetidos ao teste de resistência de união à microtração na máquina de ensaios universal EMIC DL-2000 com velocidade de 0,5mm/minuto.Os resultados foram submetidos a Análise de Variância e ao teste de Tukey HSD. O substrato hígido apresentou o maior valor médio de resistência de união (7,58±2,95 MPa). O substrato alterado por íons metálicos apresentou um valor médio de resistência de união intermediário (6,43±4,46 MPa) não diferindo estatisticamento dos demais grupos avaliados. O substrato afetado por cárie apresentou o menor valor médio de resistência de união (4,21±3,1 MPa) diferindo estatisticamente do substrato hígido. O tipo de fratura foi analisado através de imagens obtidas em MEV e a falha do tipo mista foi predominante no substrato afetado por cárie (85%) e no substrato alterado por íons metálicos (100%) enquanto que no substrato hígido houve predominância de falha adesiva (54%). Os resultados sugerem que diferentes substratos dentinários podem afetar a resistência de união do cimento resinoso RelyX Unicem.
137

Efeitos da terapia laser de baixa potência sobre o reparo ósseo: avaliação do osso submetido à radioterapia e do efeito sistêmico

Batista, Jonas Dantas January 2011 (has links)
Made available in DSpace on 2011-12-27T14:14:33Z (GMT). No. of bitstreams: 2 000433234-0.pdf: 2613434 bytes, checksum: 4d7fb810f4d177b9dfb7c7e6c479e597 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The low level laser therapy (LLLT) is used to accelerate bone repair with positive results; however, there is no study that evaluate its effect on bone compromised by ionizing radiation (IR). Another issue to be investigated is the existence of systemic effects on bone healing when the laser is applied distant from the area of the surgical bone defect. This study aimed to investigate: 1 - The effect of LLLT on bone healing in femurs previously irradiated by radiotherapy. 2 - The systemic effect of LLLT on bone repair. In the first study, twenty Wistar rats were divided into four groups: group I (control, n = 5) which was submitted only to surgical perforation (SP) of the bone; group II, submitted to SP and LLLT (n = 5); group III, submitted to IR and then SP (n = 5); and group IV, submitted to IR, SP and LLLT (n = 5). Groups II and IV received punctual laser application (DE = 6J/cm2, P = 50mW, t = 120s, and beam diameter of 0. 04cm2) immediately postoperatively, and then three times at every other 48h. Animals were euthanized at 7 days after surgery, and bone sections were evaluated morphometrically with conventional microscopy. Bone repair was only observed in non-irradiated bone, with significantly improvement in group II in comparison to group I. This result demonstrates a positive local biostimulative effect of LLLT in normal bone. However, it was not able to revert the metabolic damage associated to ionizing irradiation. In the second study, forty-five Wistar rats were submitted to osteotomy on left femur and randomly allocated into three different groups: group I, control (n = 15) submitted to confection of the bone defect only; group II, laser applied in the right femur (n = 15); group III, laser applied locally on bone defect and also on the right femur (n = 15). Laser groups (II and III) received the same laser protocol described above. Five animals of each group (n = 5) were euthanized 7, 15 and 21 days after surgery. The histomorphometric analysis showed at 7 days a significant increase of bone formation in group III compared to group I and II. At day 15 and 21, histomorphometric analysis showed no significant differences among the groups. Laser therapy presented a positive local biostimulative effect in early stage of bone healing, but a systemic effect was not observed. / A laserterapia de baixa potência (LTBP) tem sido utilizada para acelerar o processo dereparo no tecido ósseo com resultados positivos; entretanto, não existem estudos que avaliem seuefeito sobre o osso comprometido pela radioterapia. Outra questão importante a ser investigada éa existência de um possível efeito sistêmico sobre o reparo ósseo quando o laser é aplicadodistante da área do defeito ósseo cirúrgico. A presente pesquisa teve por objetivo investigar: 1- Oefeito da LTBP sobre o reparo ósseo de fêmures previamente submetidos à radioterapia. 2- Oefeito sistêmico (dose distante do defeito) da LTBP sobre o reparo ósseo. No primeiro estudo, vinte ratos machos (Rattus norvegicus, Wistar) foram distribuídos em 4 grupos com 5 animais emcada um: grupo I, submetidos à osteotomia no fêmur (OF); grupo II, submetidos à OF e LTBP; grupo III, submetidos à radioterapia no fêmur (RDT) e após 1 mês, à OF e grupo IV, submetidosà RDT e após 1 mês, OF e LTBP. Os grupos II e IV foram submetidos à LTBP (Arsenato deGálio e Alumínio - GaAlAs, = 830nm; DE = 6J/cm2, P = 50mW, t = 120s, e diâmetro do feixede 0. 04cm2) durante a cirurgia e no período pós-operatório, a cada 48 horas. Os animais foramsubmetidos à eutanásia 7 dias após a cirurgia, o osso avaliado histomorfometricamente commicroscopia de luz. O reparo ósseo foi observado somente nos grupos I e II, com um aumentosignificante no grupo II em comparação com o grupo I (ANOVA, teste de Bonferroni, P0,001). Esse resultado demonstra o efeito positivo da LTBP no osso normal. Entretanto, não foi possívelobservar efeito benéfico no osso comprometido pela radiação ionizante. No segundo estudo, quarenta e cinco ratos machos foram distribuídos em 3 grupos com 15 animais em cada: grupo Isubmetidos à osteotomia no fêmur (OF); grupo II, submetidos à OF e LTBP no fêmurcontralateral; grupo III, submetidos à OF e LTBP em ambos os fêmures. Os grupos II e III foramsubmetidos à mesma LTBP já descrita. Os animais foram eutanasiados nos períodos de 7, 15 e 21dias após a cirurgia e o osso foi avaliado histomorfometricamente com microscopia de luz. Aanálise histomorfométrica mostrou no período de 7 dias, um aumento significante de ossoneoformado no grupo III em comparação com os grupos I e II (ANOVA, teste de Bonferroni, P0. 005). Nos períodos de 15 e 21 dias a análise histomorfométrica não mostrou diferença entreos grupos. Podemos concluir que a LTBP apresentou um efeito local positivo sobre o reparoósseo, porém, não foi observado efeito sistêmico.
138

Influência da irradiação com laser nd:yag associado ao flúor nos valores de resistência de união de sistemas adesivos às dentinas sadia e cariada

Paranhos, Maria Paula Gandolfi January 2006 (has links)
Made available in DSpace on 2011-12-27T14:14:34Z (GMT). No. of bitstreams: 2 000386672-0.pdf: 7738475 bytes, checksum: 131327351db4ceb85e7af5e5a7ef43e8 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / This study evaluated, in vitro, the microtensile bond strength of two adhesive systems (Single Bond/3M-ESPE and Clearfil SE Bond/Kuraray) to caries affected and normal dentin, with or without previous treatment with Nd:YAG laser or Nd:YAG laser associated to fluoride. Dentin surfaces were exposed from 60 human third molars. Teeth were divided into 12 groups, where groups 1-6 were submitted to pH cycling for artificial caries and groups 7-12 remained with normal dentin. Dentinal surfaces received three different treatments: laser Nd:YAG irradiation (60 mJ, 15 Hz and 0. 9 W) for 1 min; laser Nd:YAG irradiation associated to fluoride in gel; and no treatment (controls). Twelve teeth, treated as mentioned above, were analyzed by SEM, Energy Dispersive Spectroscopy (EDS) and microhardness. In experimental groups, adhesive systems were applied according to manufacturers’ instructions and composite resin restorations (Filtek Z250/3M-ESPE) were made incrementally. After storage in distilled water for 24 h and 37° C, teeth were sectioned serially in both x and y directions and sticks with adhesive area of 0. 8 mm2 were obtained (25 per group). The sticks were measured and submitted to the microtensile bond strength test in an Universal Testing Machine (EMIC DL) in a 0. 5 mm/min crosshead speed. Failure mode was analyzed in SEM and in Fractographical analysis. According to general linear model univariate (GLM) and Tukey (p < 0. 05), the highest mean bond strengths were obtained in groups of normal dentin treated with Clearfil SE Bond (40. 65 MPa) and Single Bond (34. 2 MPa) according to manufacturers’ instructions. The results showed that the presence of caries affected dentin significantly decreased the mean bond strengths of the 2 adhesives systems. Laser irradiation of dentin also decreased the bond strengths of teeth treated with Clearfil SE Bond. Moreover, laser irradiation associated to fluoride also decreased the bond strength values of the 2 adhesive systems. However, caries affected dentin had better results with this association when compared to normal dentin. Mixed failure was the most common mode of failure in this study. SEM analysis showed irregularities and porosities in dentin after Nd:YAG laser irradiation due to melting and re-crystallization of this surface. Normal dentin showed closed dentinal tubules after laser irradiation and caries affected dentin showed clearer dentinal tubules because of the re-establishment of peritubular dentin. / Este estudo avaliou, in vitro, a resistência de união à microtração dos sistemas adesivos Single Bond - SB (3M/ESPE) e Clearfil SE Bond - CSE (Kuraray) à dentina sadia e cariada, com ou sem aplicação prévia do laser Nd:YAG associado ou não a presença de flúor. A superfície oclusal de 60 terceiros molares humanos foi removida para obtenção de uma superfície dentinária plana. Metade destes dentes foram submetidos à ciclagem de pH para realização de cárie artificial e a outra metade permaneceu com a dentina hígida. Os dentes foram divididos em 12 grupos, sendo que a dentina dos grupos 1-6 era cariada e dos grupos 7-12 sadia. Foram realizados 3 tratamentos distintos: irradiação da dentina com laser Nd:YAG (60 mJ, 15 Hz e 0,9 W); irradiação da dentina com laser Nd:YAG associado ao flúor em gel; e sem tratamento (controle). Doze dentes, tratados como descrito acima, foram utilizados para avaliação da microdureza, para análise em MEV e espectroscopia por energia dispersiva (EDS). Nos dentes dos grupos experimentais, a aplicação dos sistemas adesivos foi realizada de acordo com as instruções dos fabricantes e um platô de resina composta (Z250/3M) com aproximadamente 6 mm de altura foi realizado. Após, os espécimes foram armazenados em água destilada por 24 h em uma estufa de cultura a 37°C. Decorrida esta etapa, os dentes foram seccionados nos sentidos “x” e “y” para obtenção de palitos (25 por grupo) com área adesiva de 0,8 mm2. Estes palitos foram submetidos ao ensaio de microtração, em uma máquina de ensaios mecânicos (EMIC-DL), com velocidade de 0,5 mm/min. O padrão de falha foi caracterizado pela análise em MEV e análise fractográfica. Segundo o modelo linear geral univariado (GLM) e Tukey (p < 0,05), as maiores médias foram obtidas quando os sistemas adesivos foram aplicados em dentina sadia, de acordo com as instruções dos fabricantes (SB 34,2 MPa e CSE 40,65 MPa).Os resultados também mostraram que a presença de tecido cariado reduziu significativamente a resistência de união dos dois sistemas adesivos utilizados. A irradiação da dentina com laser diminuiu a resistência de união do Clearfil SE Bond e não afetou os dentes tratados com o Single Bond. A irradiação da dentina sadia com laser associado ao flúor reduziu os valores de resistência de união para os dois sistemas adesivos, embora este tratamento em dentina cariada, utilizando o Clearfil SE 12 Bond tenha mostrado resultados superiores ao Single Bond. O tipo de falha predominante foi a falha do tipo mista. A análise em MEV da dentina sadia, após aplicação do laser, mostrou uma superfície com irregularidades e porosidades devido à fusão e recristalização desta dentina, com túbulos dentinários ocluídos; a dentina cariada apresentou as mesmas características da dentina sadia irradiada, com túbulos dentinários mais nítidos devido à reestruturação da dentina peritubular.
139

Avaliação microscópica do processo de reparo ósseo na presença de enxerto ósseo humano liofilizado mineralizado e demineralizado e membrana de cortical bovina em calota craniana de ratos

Saueressig, Frederico January 2005 (has links)
Made available in DSpace on 2011-12-27T14:14:36Z (GMT). No. of bitstreams: 2 000342765-0.pdf: 7940438 bytes, checksum: a8d36361946c4de2fd70b4c4968e6358 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The aims of this study was to evaluate new bone formation and biocompatibility by the utilization of Human Demineralized and Mineralized Freeze- Dried Bone Graft (U. S. Tissue & Cell®) and evaluate if Bovine Bone Cortical Membrane (Gen-derm®) enhances the bone repair through the repair process in osseous cavities containing these materials. For that, 36 albinos rats (Rattus norvegicus) distributed in six groups according to the time of sacrifice (7, 14, 21, 30, 60 and 90 days). With a spherical drill of 2mm in diameter at low rotation three osseous cavities were made in the calvaria of each animal. One cavity had anterior orientation and two posterior one. The left posterior cavity was filled with Human Demineralized Freeze-Dried Bone Graft, the right posterior with Human Mineralized Freeze-Dried Bone Graft, while the anterior cavity did not received any material forming the control group. In three animals of each group the cavities were covered by biological membranes. The animals were sacrificed at intervals of 7, 14, 21, 30, 60 and 90 days. The specimens obtained were processed by the paraffin technique, sectioned in the transversal way and stained by H&E. The microscopic evaluation consisted in histomorphometric analysis by the measurement of the proportion of new bone formation as well the number of giant multinucleated cells in each cavity. The obtained numbers were submitted to statistic usage, using the Anova test and Bonferroni´s pairwise comparisons, considering pS0,05.The obtained results allowed us to concluded that: 1) The Bovine Bone Cortical Membrane enhances the bone repair; 2) Human Demineralized and Mineralized Freeze-Dried Bone Graft showed osteocondute properties; 3) Human Demineralized and Mineralized Freeze-Dried Bone Graft are biocompatible; 4) The animal model are suitable for the research design. / Os objetivos do presente estudo foram: avaliar o potencial de formação óssea frente à utilização de enxerto ósseo humano liofilizado desmineralizado e mineralizado da marca U. S. Tissue & Cell®; avaliar se a utilização da membrana de cortical bovina nacional Gen-derm®, influencia na cicatrização óssea e avaliar a biocompatibilidade dos enxertos ósseos, através do processo de reparo do tecido ósseo em cavidades contendo os referidos materiais. Para a realização do experimento, utilizaram-se 36 ratos albinos (Rattus norvegicus) distribuídos em seis grupos de seis animais cada, conforme a época do sacrifício (7, 14, 21, 30, 60 e 90 dias). Com uma broca esférica de 2 mm de diâmetro em baixa rotação, foram confeccionadas três cavidades, duas na porção mais posterior e uma na anterior da calota craniana de cada animal. A perfuração posterior esquerda foi preenchida com Enxerto Ósseo Humano Desmineralizado Liofilizado, a perfuração posterior direita com Enxerto Ósseo Humano Mineralizado Liofilizado e a perfuração anterior foi preenchida com o coágulo sangüíneo do animal, servindo dessa forma como grupo controle. Em três animais de cada grupo a membrana biológica foi utilizada cobrindo as cavidades preenchidas pelos biomateriais.Os animais foram sacrificados nos intervalos de 7, 14, 21, 30, 60 e 90 dias e os espécimes obtidos, processados pela técnica da parafina, sendo os cortes realizados em sentido transversal e corados por HE. A avaliação microscópica consistiu numa análise histomorfométrica, através da mensuração da área de proporção de tecido ósseo neoformado, bem como do número de células gigantes multinucleadas presentes no campo histológico. Os valores obtidos foram submetidos a avaliação estatística pela Análise de Variância (Anova) e comparações múltiplas pelo método de Bonferroni, considerando pS0,05. Os resultados obtidos permitem concluir que: 1) o uso da membrana de cortical óssea bovina desmineralizada interferiu positivamente na cicatrização óssea; 2) os materiais enxerto ósseo humano liofilizado desmineralizado e mineralizado apresentam propriedades osteocondutoras; 3) os materiais enxerto ósseo humano liofilizado desmineralizado e mineralizado são materiais biocompatíveis; 4) O modelo animal utilizado se mostrou adequado para o design da pesquisa.
140

Resistência de união de cimentos resinosos auto-adesivos à dentina

Tonial, Daniela January 2008 (has links)
Made available in DSpace on 2011-12-27T14:14:41Z (GMT). No. of bitstreams: 2 000411408-0.pdf: 3121916 bytes, checksum: d0e7791af851fbf98b39ad1f7dd9ed3f (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The purpose of this study was to evaluate, in vitro, the microtensile bond strength of self-adhesive resin luting cements to dentin, and the influence of polyacrylic acid application on the bond strength. A flat occlusal surface was obtained in extracted third human molars being it regulated with 320, 400 and 600 grit silicon carbide sandpaper, respectively. Teeth were randomly divided in five groups: Group 1 – RelyX ARC (control); Group 2 – RelyX Unicem; Group 3 - Maxcem; Group 4 – 22,5% polyacrylic acid and RelyX Unicem; Group 5: polyacrylic acid and Maxcem After applying the resin cements, composite resin blocks with 6 mm height were built. Samples were stored in distilled water at 37º C for 24 hours. After storage period, groups of tooth/resin were cut in a parallel way along the tooth axis in buccal-lingual and mesio-distal directions with cut of approximately 0,7 mm. It was obtained 20 specimens for each group, being, then, submitted to microtensile bond strength on a universal testing machine at a crosshead speed of 0,5 mm/min. Failure modes were analyzed in scanning electron microscopy.According to ANOVA and Tukey test (a=0,05), the highest mean bond strength was obtained with RelyX ARC (21. 38 MPa), which did not differ statistically from Maxcem associated to polyacrylic acid (19. 22 MPa) and RelyX Unicem associated to polyacrylic acid (17. 75 MPa) (p>0,05). These two groups did not differ statistically from RelyX Unicem (16. 98 MPa) (p>0,05). The lowest mean was obtained for Maxcem (6. 43 MPa), which differed statistically from the other groups (p<0,05). All failures were adhesive for Maxcem without polyacrylic acid, and mixed failures were predominant in the other groups. RelyX ARC achieved the highest bond strength to dentin in comparison to the self-adhesive luting resin cements. Polyacrylic acid application was effective in improving the bond strength of Maxcem, but did not influence the bond strength for RelyX Unicem. / O objetivo desse estudo foi avaliar, in vitro, a resistência de união à microtração de cimentos resinosos auto-adesivos à dentina, assim como a influência do pré-tratamento com ácido poliacrílico nessa união. Em terceiros molares humanos extraídos foi obtida uma superfície oclusal plana em dentina, sendo a mesma regularizada com lixas de carbeto de silício de granulação 320, 400 e 600, respectivamente. Os dentes foram divididos aleatoriamente em cinco grupos: Grupo 1 – RelyX ARC (controle); Grupo 2 – RelyX Unicem; Grupo 3 – Maxcem; Grupo 4 – ácido poliacrílico 22,5% e RelyX Unicem; Grupo 5: ácido poliacrílico e Maxcem. Após a aplicação dos cimentos resinosos, foram construídos blocos de resina composta com 6 mm de altura. As amostras foram armazenadas em água destilada a 37º C por 24 horas. Os conjuntos dente/resina foram cortados paralelamente ao longo eixo do dente, nos sentidos vestíbulo-lingual e mésio-distal, com secção de aproximadamente 0,7 mm. Foram obtidos 20 corpos-de-prova para cada grupo, sendo então submetidos ao teste de resistência à microtração em máquina de ensaio universal com velocidade de 0,5 mm/min. As falhas foram observadas em microscopia eletrônica de varredura. De acordo com a Análise de Variância e o teste de Tukey (a=0,05), a maior média de resistência à microtração foi para o RelyX ARC (21,38 MPa), não diferindo estatisticamente do Maxcem associado ao ácido poliacrílico (19,22 MPa) e RelyX Unicem associado ao ácido poliacrílico (17,75 MPa) (p>0,05). Estes dois últimos grupos não diferiram estatisticamente do RelyX Unicem (16,98 MPa) (p>0,05). A menor média foi obtida para o Maxcem (6,43 MPa), diferindo estatisticamente dos outros grupos (p<0,05). No grupo do Maxcem, sem pré-tratamento com ácido poliacrílico, ocorreram somente falhas adesivas, e nos demais grupos as falhas foram predominantemente mistas.

Page generated in 0.0359 seconds