• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 152
  • 5
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 158
  • 84
  • 30
  • 24
  • 22
  • 22
  • 21
  • 20
  • 19
  • 19
  • 14
  • 13
  • 13
  • 13
  • 13
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Influência da adição de nanopartículas na estabilidade de cor, microdureza e resistência à flexão de resina específica para confecção de próteses oculares /

Andreotti, Agda Marobo. January 2014 (has links)
Orientador: Daniela Micheline dos Santos / Banca: Marcelo Coelho Goiato / Banca: Simone Cecílio Hallak Regalo / Resumo: Uma alternativa segura para reabilitar pacientes com anoftalmia é a utilização de próteses oculares. O conhecimento das propriedades físicas e mecânicas da resina acrílica utilizada na confecção destas próteses é de suma importância. Nanopartículas vêm sendo adicionadas à cadeia polimérica das resinas com o objetivo de melhorar essas propriedades. Assim, o propósito desse estudo foi avaliar a influência da adição de nanopartículas na estabilidade de cor, microdureza e resistência à flexão da resina acrílica N1 específica para confecção da esclera artificial. Para isso, foram confeccionadas 300 amostras. As nanopartículas utilizadas foram Óxido de Zinco (ZnO), Dióxido de Titânio (TiO2) e Sulfato de Bário (BaSO4), nas concentrações de 1, 2 e 2,5%. As amostras foram distribuídas em 10 grupos (n=30) de acordo com o tipo e concentração de nanopartícula associada à resina acrílica N1: controle - sem nanopartícula (C), óxido de zinco 1% (ZnO 1%), óxido de zinco 2% (ZnO 2%), óxido de zinco 2,5% (ZnO 2,5%), dióxido de titânio 1% (TiO2 1%), dióxido de titânio 2% (TiO2 2%), dióxido de titânio 2,5% (TiO2 2,5%), sulfato de bário 1% (BaSO4 1%), sulfato de bário 2% (BaSO4 2%), sulfato de bário 2,5% (BaSO4 2,5%). Os ensaios de leitura de cor, microdureza e resistência à flexão foram realizados antes e após 1008 horas de envelhecimento acelerado. Os dados obtidos foram submetidos à análise estatística, utilizando-se os testes de nested ANOVA e teste de Tukey. Os resultados demonstraram que, comparando-se as diferentes nanopartículas, os grupos com TiO2 apresentaram melhor estabilidade de cor, para todas as concentrações. Em relação ao teste de microdureza, com exceção dos grupos C e com adição de óxido zinco, os valores de microdureza aumentaram após envelhecimento, sendo que, nas concentrações de 1 e 2%, os grupos com... / Abstract: A safe, aesthetic and satisfactory alternative to rehab patients with anofthalmia is the use of ocular prosthesis. It is very important to know about the physical and mechanical properties of the acrylic resin used on this prosthesis production. Nanoparticles have been added to the acrylic resins polymeric chain in order to improve these properties. So, this study aims to assess the influence of nanoparticles addition on the color stability, microhardness, and flexural resistance of artificial sclera N1 acrylic resin. To this purpose, 300 samples were made. The nanoparticles used were Zinc Oxide (ZnO), Titanium Dioxide (TiO2) and Barium Sulfate (BaSO4), at the concentrations of 1, 2 and 2%. Samples were divided into 10 groups (n=30), according to the nanoparticle and concentration associated with the resin: control - without nanoparticle (C); zinc oxide 1% (ZnO 1%) ; zinc oxide 2% (ZnO 2%); zinc oxide 2,5% (ZnO 2,5%); titanium dioxide 1% (TiO2 1%); titanium dioxide 2% (TiO2 2%); titanium dioxide 2,5% (TiO2 2,5%); barium sulfate 1% (BaSO4 1%), barium sulfate 2% (BaSO4 2%); barium sulfate 2,5% (BaSO4 2,5%). The color stability, microhardness and flexural resistance tests were performed before and after 1008 hours of accelerated aging. Data were subjected to statistical analysis using nested ANOVA and Tukey test. The results showed that, comparing the different nanoparticles, the groups with TiO2 showed better color stability at all concentrations. Microhardness values increased after artificial aging, except for groups C and ZnO and groups with TiO2 at 1 and 2% showed the highest statistically significant values compared with the other nanoparticles. Regarding flexural strength, at initial period, there was statistically significant difference between control group and the other groups. By comparing the periods, the C group... / Mestre
22

Protese ocular individualizada em resina acrílica com esfera oca /

Oliveira, Simone Helena Gonçalves de. January 1995 (has links)
Orientador: Rolf Rode / Banca: Maria Cecília Montagna Rosé / Banca: Horácio Faig Leite / Resumo: A técnica proposta visa conseguir uma diminuição de peso das próteses oculares individualizadas amplas de resina acrílica, com passos laboratoriais simplificados. Para isso utilizaram-se esferas ocas pré fabricadas de material plástico, que são incluídas dentro da esclera. Compararam-se os pesos médios de escleras maciças convencionais (5,30g) com os de escleras com esferas ocas pré-fabricadas de material plástico (3,91g), respectivamente. A redução de peso foi significante com intervalo de confiança de 95% pelo teste "t " de "Student". Foi também executada a técnica, a título de ilustração, em pacientes do Ambulatório da Disciplina de Prótese Buco-Maxilo-Facial da Faculdade de Odontologia do Câmpus de São José dos Campos-Unesp, tendo cada paciente recebido uma prótese maciça e uma prótese com esfera oca pré-fabricada de material plástico. Concluiu-se que as próteses e as escleras que possuem no seu interior a esfera oca pré-fabricada de material plástico são mais leves que as escleras maciças e que a técnica é viável para cavidades anoftálmicas amplas e é praticada em poucas sessões / Abstract: The technique proposed aims at reducing the weight of individualized ample ocular prostheses using acrylic resins as well as simplifying laboratory procedure. For that, prefabricated hollow spheres made of plastic material, were inserted in the sclera. The average weights of the solid conventional sclera (5.30g) and those of the respective prefabricated plastic ones (3.91g) were compared. The weight reduction was significative with a confidence interval of 95% by the "Student" "t" test. ln addition, for illustration purpose, the technique was applied to patients in the ward of the Maxillofacial Prostheses Dicipline of the Dentistry School in the Campus of São José dos Campos - UNESP, having each patient received a solid prosthesis and a hollow prefabricated one made of plastic material. It has been concluded that the prostheses material spheres were inserted are lighter than the ones which received solid spheres; furthermore, thr technique is viable for ample anophtalmic cavities and requires few sessions / Mestre
23

Avaliação da estabilidade cromática da pintura de íris em próteses oculares polimerizadas por energia de microondas, variando a cor, a tinta e o método de secagem /

Fernandes, Aline Úrsula Rocha. January 2004 (has links)
Orientador: Marcelo Coelho Goiato / Resumo: A íris artificial é a estrutura da prótese ocular responsável pela sua dissimulação e estética. O propósito do presente trabalho foi avaliar a alteração de cor de tintas utilizadas na pintura de íris em próteses oculares polimerizadas por energia de microondas, variando-se tinta, cor e método de secagem. Para o estudo, foram confeccionados cinco discos em resina termopolimerizável por microondas para cada tinta analisada: acrílica hidrossolúvel, automotiva à base de nitrocelulose, guache hidrossolúvel e a óleo, nas cores marrom e azul, para os métodos de secagem natural e por radiação infravermelha, perfazendo um total de 80 corpos-de-prova. Cada corpo-de-prova foi constituído por um disco de resina acrílica incolor e outro, de igual dimensão, de resina acrílica de coloração branca de esclera e, entre os dois discos, a pintura. Os corposde- prova foram submetidos a uma câmara de envelhecimento acelerado sob radiação ultravioleta, por 1008 horas. Para avaliar as variações de cor foi usado um espectrofotômetro de reflexão. Os resultados foram analisados estatisticamente por Análise de Variância e teste de Tukey a 5% de significância. Todas as tintas sofreram alteração cromática. A tinta a óleo apresentou a maior resistência frente ao envelhecimento acelerado, independente da cor e do método de secagem. / Abstract: The artificial iris is the structure of the ocular prosthesis responsible for its dissimulation and aesthetics. The objective of the present study was to evaluate the color stability of paint used for iris painting for ocular prosthesis polymerized with microwaves, varying painting, color and drying method. For the study, 80 discs in heat-curing for microwaves acrylic resin were made, five discs for each paint analyzed: acrylic water-soluble paints, automotive nitrocellulose paints, watercolor paints and oil paints, for the colors brown and blue, for both natural and infrared drying methods. Each specimen was constituted of one disc in colorless acrylic resin and another colored with a basic sclera pigment. The painting was accomplished in one of the surfaces of one of the discs. The specimens were submitted to an artificial aging chamber under ultraviolet light, during 1008 hours. To evaluate color changes a reflective spectrophotometer was used. The data were statistically analyzed by Variance Analysis and Tukey's test. All paints suffered color alteration. The oil paints presented the highest resistance to artificial aging regardless the pigment and the drying method. / Mestre
24

Avaliação da adesão de Staphylococcus spp. em resina acrílica específica para prótese ocular e alteração de cor de botões de íris artificiais, variando a cor e as técnicas de obtenção, ambos após desinfecção química /

Moreno, Amália. January 2014 (has links)
Orientador: Marcelo Coelho Goiato / Co-orientador: Daniela Micheline dos Santos / Banca: Eduardo Piza Pellizzer / Banca: Humberto Gennari Filho / Banca: Simone Cecílio Hallak Regalo / Banca: Célia Regina Moreira Lanza / Resumo: As próteses oculares são responsáveis pela recuperação da estética e auto-estima do usuário. Assim, os materiais utilizados na confecção de prótese ocular devem possuir propriedades específicas para sua indicação e durabilidade principalmente aos procedimentos de desinfecção pelo paciente. Desse modo, este estudo teve como objetivo verificar a efetividade de diferentes soluções desinfetantes na remoção de biofilme de duas espécies de Staphylococcus spp., desenvolvidas na superfície de resina acrílica específica para prótese ocular e avaliar a alteração de cor de botões de íris artificiais confeccionadas por diferentes técnicas antes e após a polimerização e quando influenciadas pela desinfecção química. Para o teste de microbiologia, 396 amostras em resina acrílica para prótese ocular N1 foram confeccionadas (1,0 cm em diâmetro e 0,3 cm em espessura), sendo metade dessas amostras para formação de biofilme de S. epidermidis e a outra metade para formação de biofilme de S. aureus, ambos na superfície da amostra. Para cada cepa bacterina, 66 amostras foram submetidas a formação de biofilme em sua superfície durante três diferentes tempos: inicial (24h), intermediário (48h) e maduro (72h). Em seguida as amostras foram distribuídas aleatoriamente (unidade amostral n=6) para um dos tratamentos desinfetantes: água destilada durante 10, 15, 30 min e 6 h (controle-CTL); sabão neutro (NES) durante 30 min; Opti-Free durante 30 min e 6 h; Efferdent (EFF) durante 15 min; e gluconato de clorexidina (0,5%; 2% e 4%) (CHX) durante 10 min. Após o tratamento desinfetante, as amostras acrílicas foram imediatamente agitadas para desprendimento do biofilme. A contagem de colônias foi verificada por análise do número de UFC/mL. Para a análise de alteração de cor 300 amostras simulando próteses oculares foram confeccionadas, sendo metade... / Abstract: Considering that ocular prostheses restore esthetics and patient's self-esteem, the materials used for prosthesis fabrication should present appropriate properties regarding indication and reliability after the disinfection procedures. So, the aim of this study was to assess the effectiveness of different disinfectant solutions against two species of Staphylococcus spp. cultured on ocular prosthesis acrylic resin. In addition, the chromatic change of artificial iris buttons fabricated with different techniques was also evaluated before and after polymerization and disinfection. For the microbiology tests 396 acrylic specimens were fabricated (1.0 cm in diameter and 0.3 cm in thickness). Half of the samples were made for biofilm formation of S. epidermidis and half were made for biofilm formation of S. aureus, both on the sample surface. For each strain, 66 samples were underwent to biofilm formation on the liner surface for three different points: initial (24h), intermediate (48h) and mature (72h). Afterwards the specimens were randomly assigned (unit sample n = 6) to one of disinfectant treatments: distilled water for 10, 15, 30 min and 6 h (control-CTL); treated with neutral soap (NES) for 30 min; treated with Opti-Free (OPT) for 30 min and 6 h; treated with Efferdent (EFF) for 15 min; and treated with (0.5%, 2% and 4%) chlorhexidine gluconate (CHX) for 10 min. After the treatments, the specimens were vortexed to disrupt the biofilm, and residual cells were counted (cell/mL). For the color meansurations a total of 300 samples simulating ocular prosthesis were fabricated. Half of the samples were made with blue artificial irises, and half were made with brown artificial irises. For each color, 50 samples were fabricated according to one of the following techniques: PE - conventional technique, CA - prefabricated... / Doutor
25

Avaliação da superfície ocular de cães com protrusão da glândula da terceira pálpebra

Mota, Luana Paes de Aguiar 29 August 2014 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Agronomia e Veterinária, Programa de Pós-Graduação em Saúde Animal, 2014. / Submitted by Jaqueline Ferreira de Souza (jaquefs.braz@gmail.com) on 2014-11-03T14:42:03Z No. of bitstreams: 1 2014_LuanaPaesdeAguiarMota.pdf: 1499752 bytes, checksum: 77902a8b2bff8efacfd2065894ebf23d (MD5) / Approved for entry into archive by Guimaraes Jacqueline(jacqueline.guimaraes@bce.unb.br) on 2014-11-12T13:54:30Z (GMT) No. of bitstreams: 1 2014_LuanaPaesdeAguiarMota.pdf: 1499752 bytes, checksum: 77902a8b2bff8efacfd2065894ebf23d (MD5) / Made available in DSpace on 2014-11-12T13:54:30Z (GMT). No. of bitstreams: 1 2014_LuanaPaesdeAguiarMota.pdf: 1499752 bytes, checksum: 77902a8b2bff8efacfd2065894ebf23d (MD5) / O presente trabalho foi um estudo abrangente e optou-se por dividi-lo em dois artigos. O primeiro redigido e formatado segundo as normas de submissão para publicação na revista Pesquisa Veterinária Brasileira (Brazilian Journal of Veterinary Research, ISSN: 0100-736X; Fator de impacto 0.51, Qualis A2) e o segundo, redigido e formatado segundo as normas de submissão para publicação da revista Veterinary Ophthalmology (Fator de impacto 0.959, ISI Journal Citation Reports © Ranking: 2012: 66/143 (Veterinary Sciences) Online ISSN: 1463-5224)”. ______________________________________________________________________________ RESUMO DO ARTIGO 1 / O teste de cristalização da lágrima (TCL) ainda não foi padronizado em cães. Este trabalho propõe padroniza-lo e validar o programa STEPanizer © stereology tool version 1.0 como método de classificação complementar para o teste. Foram utilizados 31 cães (62 olhos), sem predominância de sexo ou raça, com idade média de 18,8 ± 18.4 meses. Dentre estes, 14 apresentavam a superfície ocular hígida e 17 apresentavam protrusão unilateral da glândula da terceira pálpebra. Foram realizados em todos os cães, testes de rotina para avaliar a higidez da superfície ocular. O TCL foi classificado de acordo com Rolando (1984) e pelo programa STEPanizer. Neste, testou-se a avaliação com 16, 25, 36, 49, 64, 81 e 100 pontos equidistantes de contagem, no sistema teste que fica sobreposto à imagem, correlacionando-os com a classificação segundo Rolando (1984). Os dados foram analisados com o software Statistical Analysis System (SAS®). Valores de maior correlação (r), p < 0.05, menor erro mean square (MSE) e maior coeficiente de determinação (R2 ajustado) foram utilizados para definir o melhor número de pontos no STEPanizer. O TCL classificado segundo Rolando (1984) resultou, em média, tipo II para os animais hígidos e tipo III para os animais com protrusão da glândula da terceira pálpebra. A classificação do TCL utilizando o STEPanizer mostrou melhor correlação com a classificação de Rolando quando feita por meio da contagem com 100 pontos equidistantes (r - 0.9; MSE 0.38 e R2 ajustado 0.81). A classificação para o TCL utilizando o STEPanizer mostrou-se objetiva e factível de ser empregada na rotina clínica, sendo útil como ferramenta de padronização para a classificação do TCL, feita segundo Rolando (1984). ______________________________________________________________________________ RESUMO DO ARTIGO 2 / Objetivo Avaliar a superfície ocular de cães com protrusão da glândula da terceira pálpebra, antes e após a cirurgia de reposicionamento da glândula, comparativamente a animais hígidos. Animais vinte e sete cães, sendo 14 sem alterações de superfície ocular (grupo controle – GC) e 13 acometidos unilateralmente pela protrusão da glândula da terceira pálpebra (grupo afetado – GA), machos ou fêmeas, com idade media de 20,8 ± 19 meses. Procedimentos Foram realizados, em todos os cães, o teste lacrimal de Schirmer (TLS); o tempo de ruptura do filme lacrimal (TRFL); a coloração com fluoresceína (FLUO), a análise histopatológica do fórnix conjuntival (BIO) e o teste de cristalização da lagrima (TCL), classificado como o proposto por Rolando (1984) e por meio do programa STEPanizer © Stereology tool version 1.0. Sendo que no GA, os testes também foram realizados nos dias 7, 15, 30 e 60 após a reposição da glândula protruída. Os dados foram analisados com o software Statistical Analysis System (SAS ®). Valores de maior correlação (r), p < 0.05, menor erro mean square (MSE) e maior coeficiente de determinação (R2 ajustado) foram considerados significativos. Resultados Não se verificou diferença significativa para os testes TLS, TRFL e FLUO nem antes, nem após o procedimento de reposição da glândula. O TCL classificado de acordo com o STEPanizer mostrou piora significativa após o procedimento cirúrgico (p < 0,001), piora não significativa quando classificado de acordo com Rolando (1984). A classificação do TCL 20 pelo STEPanizer é altamente correlacionada com a de Rolando, tanto nos olhos dos animais hígidos (r – 0,94), como nos olhos afetados pela protrusão (r – 0,91). A concentração de células caliciformes por campo de grande aumento (400x) para os olhos do GC (22,28 ± 5,78) foi significativamente maior do que no GA (18,45 ± 10,6). Conclusão O diagnóstico e a terapêutica cirúrgica precoce provavelmente evitaram os sinais característicos da cronicidade desta afecção sobre a superfície ocular dos animais deste estudo. A classificação do TCL utilizando o STEPanizer, mostrou-se mais sensível do que a de Rolando (1984). As alterações visualizadas no olho sem a protrusão foram as mesmas visualizadas no olho afetado pela protrusão, o que gera a hipótese de que a etiopatogenia da doença pode ter início com alterações de superfície ocular ainda não descritas em literatura. ______________________________________________________________________________ ABSTRACT OF THE ARTICLE 1 / The tear ferning test (FT) has no standard in dogs. This paper proposes this standardization it and validation using the STEPanizer © Stereology tool version 1.0 program (STEPanizer) as a complementary classification method for the test. Thirty one dogs (62 eyes) of no predominant sex or bread, with an average age of 18.8 ± 18.4 months were used. Among these, 14 had a healthy ocular surface and 17 had a unilateral third eyelid gland protrusion. Routine tests for evaluating the health of the ocular surface were performed on all dogs. The FT was classified according to Rolando (1984) and by the STEPanizer program. The STEPanizer uses a test system with equidistant points overlaid on the analyzed image. A total of 16, 25, 36, 49, 64, 81 and 100 equidistant points were evaluated, correlating them with the Rolando (1984) classification. Data were analyzed with the Statistical Analysis System (SAS®) software. Higher correlation (r) coefficients, p < 0.05, lower mean square error (MSE) and higher adjusted R2 were used to define the best number of points. Healthy animals showed, on average, FT classification according Rolando (1984) of Type II in healthy animals and Type III in animals with third eyelid gland protrusion. The FT regression on STEPanizer using 100 equidistant points (r - 0.9; MSE 0.38 and adjusted R2 0.81) showed the highest correlation with Rolando (1984) classification. The FT classification using STEPanizer proved to be objective and feasible for use in clinical routine, being useful as a standardized tool for the FT Rolando (1984) classification. INDEX TERMS: eye, ocular surface, validation, Rolando (1984), test system, third eyelid gland protrusion. ______________________________________________________________________________ ABSTRACT OF THE ARTICLE 2 / Objective Evaluate third eyelid gland protrusion dogs ocular surface both before and after surgical repositioning of the gland, compared to healthy animals. Animals Twenty-seven dogs, 14 with healthy ocular surface (control group - CG) and 13 unilaterally affected by third eyelid gland protrusion (affected group - AG), male or female, with a mean age of 20.8 ± 19 months. Procedures In all dogs were performed the Schirmer tear test (STT); the breakup time of the tear film (BUT); the fluorescein staining (FLUO), the histopathological analysis of the conjunctival fornix (BIO) and the tear Ferning test (FT), classified as proposed by Rolando (1984) and with STEPanizer © Stereology tool version 1.0 program. On AG, the tests were also performed on 7, 15, 30 and 60 days after the gland replacement. Data were analyzed with the Statistical Analysis System software. Higher correlation values, p < 0.05, lower mean square error and higher determination coefficient were significant. Results No statistical difference was found for STT, BUT and FLUO tests. FT classified using STEPanizer showed significant worse after surgery (p <0.001), but no significant when classified according to Rolando (1984). On AG, changes in the eyes without protrusion were the same displayed in the affected eyes. Conclusion Early diagnosis and surgical therapy of affected dogs prevented chronic changes on their ocular surface. The FT rating using the STEPanizer was more sensitive than Rolando (1984) classification. It’s assumed that the disease pathogenesis may begin with changes in ocular surface not previously described in the literature.
26

Medida de parametros biomecânicos do olho com laser de baixa coerência. / Measuring biomechanical parameters of the eye using low coherence laser.

Antonio Cesar de Oliveira 26 May 1994 (has links)
Neste trabalho desenvolvemos um novo método para análise biométrica do olho. Essa análise se compõe de medidas dos parâmetros biomecânicos, ou seja, espessura da córnea, distancia entre a córnea e o cristalino, espessura do cristalino, e distancia entre o cristalino e a retina. Este novo método funciona utilizando o princípio da interferometria com laser de baixa coerência. O conhecimento desses parâmetros e de suma importância para o fornecimento de dados necessários para o implante de lentes intra-oculares, em casos de catarata. Alem disso, eles permitem diagnosticar patologias clinicamente caracterizadas por suas alterações. O instrumento convencionalmente utilizado para essas medidas e o biômetro ultra-sônico. Embora esses biômetros sejam práticos e eficientes, a resolução por análise ultra-sônica esta limitada ao fato do tecido ocular não fornecer ecos satisfatórios em freqüências muito acima de 10 MHz. Uma limitação na resposta de freqüência determina uma subseqüente limitação na precisão de medida, já que esta será tanto maior quanta maior a freqüência. Uma variedade de técnicas diferentes tem sido experimentada nos últimos dez anos visando estabelecer um método mais preciso. Entretanto, várias das alternativas existentes têm sido rejeitadas devido à complexidade operacional e altos custos. A técnica interferométrica, entretanto, reúne alta resolução, simplicidade operacional e baixo custo. Isso pode ser constatado pelos resultados obtidos, os quais revela um enorme potencial aplicativo para futuros trabalhos de pesquisa ou mesmo de diagnose. / In this work we have developed a new method for biometric analysis of the eye. This analysis consists of measurements of biomechanical parameters, like thickness of the cornea, distance between the cornea and the crystalline lens, thickness of the crystalline lens and distance between the crystalline lens and the retina. In this new method we use the interferometric principle with a low coherence laser. The knowledge of these parameters is very important in order to supply the necessary data for the implant of intraocular lenes, in the cases of cataract. Besides of allow the diagnosis of the pathologies, which are characterized by their changes. The instrument used in the measurements is an ultrasonic biometer. However the resolution of this instrument is limited by the ocular tissue, which does not allow satisfactory echos in frequencies above 10 MHz. A variety of the techniques have been used in the last ten years in the order to establish a more accurate method. However most of the existing alternatives have been rejected due to operational complexity and high cost. The interferometric technique unites high resolution, operational simplicity and low cost. This can be concluded by the results obtained in this work, which demonstrate the great potentiality of the method for future in academic research or clinical diagnosis.
27

Urbanização no entorno de lagoa costeira em espaço metropolitano

ASSIS, Daniella Roberta Silva de 22 February 2013 (has links)
Submitted by Felipe Lapenda (felipe.lapenda@ufpe.br) on 2015-03-12T14:04:01Z No. of bitstreams: 2 Dissertaçao Daniella de Assis PRODEMA.pdf: 4472831 bytes, checksum: 56a0aab12255a3e154545c36c5b91100 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Made available in DSpace on 2015-03-12T14:04:01Z (GMT). No. of bitstreams: 2 Dissertaçao Daniella de Assis PRODEMA.pdf: 4472831 bytes, checksum: 56a0aab12255a3e154545c36c5b91100 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Previous issue date: 2013-02-22 / A referida pesquisa procura analisar os resultados da ocupação urbana no entorno de ecossistemas frágeis em espaços urbanos, averiguando em que medida as políticas públicas têm contribuído para a conservação desses ecossistemas, tomando como referência a Lagoa Olho D’Água, localizada no município de Jaboatão dos Guararapes, no estado de Pernambuco. Lagoas costeiras são ecossistemas frágeis à ação antrópica, pela sua alta complexidade ecológica, importante para o processo de estabilidade ambiental e manutenção da biodiversidade. Portanto, é necessário discutir a forma como estes ecossistemas devem ser conservados, principalmente, quando inseridos em áreas urbanas. Pois a urbanização tornou-se uma prática das mais agressivas à natureza, sendo concretizada, muitas vezes, de maneira insustentável. O estudo fundamenta-se no método dialético, enfatizando que existem incoerências que dão origem a novas contradições, passando a demandar soluções urgentes. A abordagem utiliza também o recurso da interdisciplinaridade, quando se propõe a promover um diálogo entre os saberes teóricos, práticos e vivenciais dos atores sociais envolvidos. Constatou-se que, apesar dos tipos de solos do entorno da lagoa serem propensos a inundações constantes, há um crescente processo de ocupação e uso desordenado, proporcionando alterações negativas neste ecossistema, como o lançamento de efluentes industriais e domésticos não tratados dos bairros adjacentes, através de seis canais de ordem primária e quatro de ordem secundária. Em suas imediações, diversos tipos de ocupações entre assentamentos, loteamentos e conjuntos habitacionais, onde o saneamento básico é quase inexistente, geram alterações na qualidade ambiental deste ecossistema. Contudo, existe legislação específica para este ecossistema, como o Código Florestal Brasileiro que considera de preservação permanente a vegetação ao redor das lagoas. Na esfera estadual existem Leis declarando a área da Lagoa Olho D’Água como sendo de interesse social, destinada à requalificação urbana. No âmbito municipal, a Lei Orgânica mostra a Lagoa Olho D'Água como Área de Proteção Ambiental. Dessa forma, pode-se concluir que a urbanização descontrolada em áreas ambientalmente vulneráveis, como na Lagoa Olho D’Água, pode acarretar na perda irreparável da biodiversidade deste ecossistema, logo, o modo de ocupação precisa ser devidamente planejado e adaptável às fragilidades naturais e às necessidades da população local. Obviamente, esta não é uma tarefa das mais fáceis, tendo como principal ponto de entrave os conflitos de interesses entre os habitantes da localidade e o poder público. Tais conflitos podem agravar-se com adensamento populacional, interferindo de maneira negativa na qualidade de vida das pessoas que habitam a área, interferindo ainda mais no ecossistema original, distanciando o natural do social. Lembrando que a apropriação e o uso dos recursos naturais não ocorrem de forma pacífica, pois existem interesses e conflitos, possíveis ou explícitos, entre atores sociais, que interferem nos meios naturais e edificados, tendo em vista o seu controle ou a sua defesa.
28

Camada de fibras nervosas da retina em portadores de esquistossomose hepatoesplênica:análise por tomografia de coerência óptica

CELINO, Ana Carolina Borges Loureiro 31 January 2009 (has links)
Made available in DSpace on 2014-06-12T16:25:26Z (GMT). No. of bitstreams: 2 arquivo3123_1.pdf: 1759622 bytes, checksum: 82c6fa24829119f3da4a0e312eebc64e (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2009 / Objetivos: Avaliar a espessura da camada de fibras nervosas da retina (CFNR) em portadores de esquistossomose mansônica na forma hepatoesplênica (EHE), utilizando a tomografia de coerência óptica (OCT). Métodos: Realizou-se estudo prospectivo, analítico, de corte transversal, tipo caso controle. O grupo de doentes foi composto por 24 indivíduos (13 femininos e 11 masculinos), com idades variando entre 27 e 73 anos (55,7 ±11,6 anos). No grupo controle foram incluídos 22 indivíduos (12 femininos e 10 masculinos) com idades entre 31 e 77 anos (55,4 ±16,5 anos). Dos 92 olhos avaliados, três foram excluídos por apresentarem opacidade de meios que impossibilitaram o exame. Todos os participantes foram submetidos a exame oftalmológico completo e OCT da camada de fibras nervosas da retina. Resultados: A média das espessuras da CFNR foi de 98,1 ±15,2&#956;m no grupo dos doentes e 114,2 ±10,0 &#956;m no grupo controle (p< 0,001). Conclusão: Observou-se diminuição significante da espessura da CFRN, em todos os quadrantes, nos pacientes com EHE. É possível que as alterações hemodinâmicas secundárias à hipertensão porta em portadores de EHE sejam responsáveis por disfunção na microcirculação da retina, gerando isquemia, justificando os achados do atual estudo
29

"Altera????es neuroftalmol??gicas na doen??a de chagas"

Villas-B??as, Fl??via da Silva 23 March 2018 (has links)
Submitted by carla santos (biblioteca.cp2.carla@bahiana.edu.br) on 2018-08-15T19:35:26Z No. of bitstreams: 1 FL??VIA DA SILVA VILLAS-B??AS.pdf: 2796975 bytes, checksum: 86a0ab8784427655cff4212727c5e6e6 (MD5) / Approved for entry into archive by JOELMA MAIA (ebmsp-bibliotecacp2@bahiana.edu.br) on 2018-08-16T16:42:16Z (GMT) No. of bitstreams: 1 FL??VIA DA SILVA VILLAS-B??AS.pdf: 2796975 bytes, checksum: 86a0ab8784427655cff4212727c5e6e6 (MD5) / Made available in DSpace on 2018-08-16T16:42:16Z (GMT). No. of bitstreams: 1 FL??VIA DA SILVA VILLAS-B??AS.pdf: 2796975 bytes, checksum: 86a0ab8784427655cff4212727c5e6e6 (MD5) Previous issue date: 2018-03-23 / Fundamento: A doen??a de Chagas ?? uma infec????o parasit??ria sist??mica que afeta diversos ??rg??os, inclusive o olho, e pode evoluir com altera????es neuroftalmol??gicas na fase cr??nica da doen??a. No entanto, nenhum estudo foi realizado, at?? o momento, para esclarecer os padr??es e caracter??sticas das altera????es neuroftalmol??gicas a fim de oferecer possibilidades de preven????o e desenvolvimento de terapias precoces. Objetivos: (1) explorar a hip??tese de que a doen??a de Chagas predisp??e a altera????es neuroftalmol??gicas; (2) testar a hip??tese de que a doen??a de Chagas predisp??e a redu????o da press??o intraocular; (3) explorar potenciais causas cardiovasculares para altera????es neuroftalmol??gicas em pacientes chag??sicos. Metodologia: estudo observacional, de corte transversal, incluindo pacientes encaminhados do ambulat??rio de Chagas e Insufici??ncia Card??aca do Hospital S??o Rafael, no per??odo de junho de 2014 a junho de 2016, com doen??a de Chagas confirmada por dois testes sorol??gicos positivos. Pacientes controles, pareados por sexo e idade, foram recrutados a partir dos funcion??rios do Instituto Brasileiro de Oftalmologia e Preven????o da Cegueira, onde o estudo foi realizado. Os pacientes foram submetidos a exames oftalmol??gicos, incluindo medida da acuidade visual, refra????o, medida da press??o intraocular, avalia????o estrutural e funcional do nervo ??ptico e camada de fibras nervosas por meio de retinografia, tomografia de coer??ncia ??ptica e perimetria automatizada padr??o. Resultados: foram avaliados 41 indiv??duos portadores da doen??a de Chagas e 41 controles, sendo 26 (63%) do sexo feminino, com m??dia de idade de 59??8 anos em ambos os grupos (p= 0,96). Dentre os pacientes chag??sicos, 15 (37%) apresentavam a forma card??aca com disfun????o do ventr??culo esquerdo; 14 (34%), forma card??aca sem disfun????o do ventr??culo esquerdo e 12 (29%), forma indeterminada. Em rela????o ao Objetivo 1, foram observadas altera????es neuroftalmol??gicas em 24 pacientes (58,5%) do grupo chag??sico e 07 (17%) do grupo controle (p ??? 0,01). Foram vistas altera????es do nervo ??ptico sugestivas de glaucoma, afinamento localizado da rima neural, hemorragia peripapilar, palidez do nervo ??ptico, defeito da camada de fibras nervosas localizado e redu????o da espessura da camada de fibras nervosas peripapilar. Observou-se que a preval??ncia das altera????es neuroftalmol??gicas n??o mostrou diferen??a entre os pacientes chag??sicos com e sem disfun????o ventricular (n= 15 e n= 26, respectivamente; p=0,13). Por??m, a compara????o dos chag??sicos (n= 13) sem disfun????o ventricular com os controles (n=41) mostrou diferen??a significante (p=0,005). O exame de tomografia de coer??ncia ??ptica mostrou diminui????o da espessura global da camada de fibras nervosas (89 ?? 9.7 ??m) e da espessura da camada de fibras nervosas inferior (113 ?? 17.4 ??m) nos pacientes chag??sicos. Nos controles, esses valores foram de 94 ?? 10.9 ??m com p =0.03 e 121 ?? 19.7 ??m com p=0.03, respectivamente. No Objetivo 2, n??o foi observada diferen??a na press??o intraocular entre os grupos chag??sico e controle (m??dias 14,5 ?? 4 mmHg e 14 ?? 4mmHg, respectivamente, p=0,53). Na avalia????o do Objetivo 3, n??o foram observadas diferen??as nos padr??es cardiovasculares dos pacientes chag??sicos com e sem altera????es neuroftalmol??gicas. Conclus??es: Os pacientes com doen??a de Chagas tiveram maior preval??ncia de altera????es neuroftalmol??gicas do que os controles sem a doen??a. A press??o intraocular n??o influenciou os achados descritos, uma vez que foi semelhante entre os grupos. A compara????o da estrutura e fun????o card??acas dos pacientes chag??sicos que tiveram altera????es neuroftalmol??gicas com os que n??o tiveram, sugeriu uma influ??ncia da doen??a de Chagas independente da cardiopatia apresentada.
30

Avaliação clínica e microbiológica da secreção conjuntival em usúarios de prótese ocular em resina acrílica /

Neves, Ana Christina Claro. January 2000 (has links)
Orientador : Rolf Rode / Banca: Marcia André / Banca: Plínio Moroni / Banca : Antonio Olavo Cardoso Jorge / Banca: Sigmar de Mello Rode / Resumo: Este trabalho objetivou avaliar a microbiota bacteriana e fúngica das cavidades anoftálmicas, próteses oculares e olhos contralaterais de 43 usuários de prótese ocular em resina acrílica, unilateral, e relacionar a quantidade de secreção conjuntival presente nessas cavidades com a microbiota conjuntival, frequência de limpeza, tempo de uso e tempo decorrido desde o último polimento da prótese. Todos os pacientes apresentavam secreção conjuntival e microbiota Gram positiva nas cavidades anoftálmicas, Os microrganismos mais frequentemente isolados das 43 cavidades anoftálmicas, por ordem decrescente de freqüência, foram: Staphyfococcus coagulase negativos, Staphylococcus aureus, Candída albicans, Proteus mirabilis, Citrobacter koseriana, Streptococcus pyogenes, Pseudomonas aeruginosa, Enterobacter sakazakii e Enterobacter aerogenes. Microbiota Gram negativa foi isolada de oito cavidades e fúngica, de três. O estudo estatístico dos dados evidenciou relação não significativa entre a quantidade de secreção conjuntival e a presença de microbiota Gram negativa• nas cavidades; e entre a quantidade de secreção conjuntival e a frequência de limpeza da prótese ocular. Correlação, estatisticamente significativa, foi constatada entre a quantidade de secreção conjuntiva! e o tempo de uso e o tempo decorrido desde o último polimento da prótese / Abstract: The purpose of this work was to evaluate the bacterial and fungic microbiota of the anophthalmic sockets, ocular prosthesis and fellow eyes of forty three acrylic resin prosthesís carrying patients, and thereby relate the amount of conjunctival discharge to the presence of organisms, frequency of prosthesis cleaning, time of use and elapsed time since the last prosthesis polishing. All patients showed conjunctival discharge and Gram positive organisms in the anophthalmic sockets. The predominant organisms in the anophthalmic sockets were Staphylococcus coagulase negative, Staphylococcus aureus, Candida albicans, Proteus mirabilis, Citrobacter koseriana, Streptococcus pyogenes, Pseudomonas aeruginosa, Enterobacter sakazakii e Enterobacter aerogenes. Gram negative bacteria were found in eight anophthalmic sockets and fungi in three. No relation was found between the amount of the conjunctival discharge and the presence of Gram negative bacteria in the anophthalmic socket, nor with the frequency of prosthesis cleaning. However, there was a significant relation between the amount of conjunctival discharge and time of prosthesis use, as well as time elapsed since the last prosthesis polishing / Doutor

Page generated in 0.0243 seconds