• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 152
  • 5
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 158
  • 84
  • 30
  • 24
  • 22
  • 22
  • 21
  • 20
  • 19
  • 19
  • 14
  • 13
  • 13
  • 13
  • 13
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Avaliação da estabilidade cromática da pintura de íris em próteses oculares polimerizadas por energia de microondas, variando a cor, a tinta e o método de secagem

Fernandes, Aline Úrsula Rocha [UNESP] January 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2004Bitstream added on 2014-06-13T19:16:54Z : No. of bitstreams: 1 fernandes_aur_me_araca.pdf: 952229 bytes, checksum: 8e65200d34f1586880d463d53baa7659 (MD5) / Universidade Estadual Paulista (UNESP) / A íris artificial é a estrutura da prótese ocular responsável pela sua dissimulação e estética. O propósito do presente trabalho foi avaliar a alteração de cor de tintas utilizadas na pintura de íris em próteses oculares polimerizadas por energia de microondas, variando-se tinta, cor e método de secagem. Para o estudo, foram confeccionados cinco discos em resina termopolimerizável por microondas para cada tinta analisada: acrílica hidrossolúvel, automotiva à base de nitrocelulose, guache hidrossolúvel e a óleo, nas cores marrom e azul, para os métodos de secagem natural e por radiação infravermelha, perfazendo um total de 80 corpos-de-prova. Cada corpo-de-prova foi constituído por um disco de resina acrílica incolor e outro, de igual dimensão, de resina acrílica de coloração branca de esclera e, entre os dois discos, a pintura. Os corposde- prova foram submetidos a uma câmara de envelhecimento acelerado sob radiação ultravioleta, por 1008 horas. Para avaliar as variações de cor foi usado um espectrofotômetro de reflexão. Os resultados foram analisados estatisticamente por Análise de Variância e teste de Tukey a 5% de significância. Todas as tintas sofreram alteração cromática. A tinta a óleo apresentou a maior resistência frente ao envelhecimento acelerado, independente da cor e do método de secagem. / The artificial iris is the structure of the ocular prosthesis responsible for its dissimulation and aesthetics. The objective of the present study was to evaluate the color stability of paint used for iris painting for ocular prosthesis polymerized with microwaves, varying painting, color and drying method. For the study, 80 discs in heat-curing for microwaves acrylic resin were made, five discs for each paint analyzed: acrylic water-soluble paints, automotive nitrocellulose paints, watercolor paints and oil paints, for the colors brown and blue, for both natural and infrared drying methods. Each specimen was constituted of one disc in colorless acrylic resin and another colored with a basic sclera pigment. The painting was accomplished in one of the surfaces of one of the discs. The specimens were submitted to an artificial aging chamber under ultraviolet light, during 1008 hours. To evaluate color changes a reflective spectrophotometer was used. The data were statistically analyzed by Variance Analysis and Tukey’s test. All paints suffered color alteration. The oil paints presented the highest resistance to artificial aging regardless the pigment and the drying method.
12

Medida de parametros biomecânicos do olho com laser de baixa coerência. / Measuring biomechanical parameters of the eye using low coherence laser.

Oliveira, Antonio Cesar de 26 May 1994 (has links)
Neste trabalho desenvolvemos um novo método para análise biométrica do olho. Essa análise se compõe de medidas dos parâmetros biomecânicos, ou seja, espessura da córnea, distancia entre a córnea e o cristalino, espessura do cristalino, e distancia entre o cristalino e a retina. Este novo método funciona utilizando o princípio da interferometria com laser de baixa coerência. O conhecimento desses parâmetros e de suma importância para o fornecimento de dados necessários para o implante de lentes intra-oculares, em casos de catarata. Alem disso, eles permitem diagnosticar patologias clinicamente caracterizadas por suas alterações. O instrumento convencionalmente utilizado para essas medidas e o biômetro ultra-sônico. Embora esses biômetros sejam práticos e eficientes, a resolução por análise ultra-sônica esta limitada ao fato do tecido ocular não fornecer ecos satisfatórios em freqüências muito acima de 10 MHz. Uma limitação na resposta de freqüência determina uma subseqüente limitação na precisão de medida, já que esta será tanto maior quanta maior a freqüência. Uma variedade de técnicas diferentes tem sido experimentada nos últimos dez anos visando estabelecer um método mais preciso. Entretanto, várias das alternativas existentes têm sido rejeitadas devido à complexidade operacional e altos custos. A técnica interferométrica, entretanto, reúne alta resolução, simplicidade operacional e baixo custo. Isso pode ser constatado pelos resultados obtidos, os quais revela um enorme potencial aplicativo para futuros trabalhos de pesquisa ou mesmo de diagnose. / In this work we have developed a new method for biometric analysis of the eye. This analysis consists of measurements of biomechanical parameters, like thickness of the cornea, distance between the cornea and the crystalline lens, thickness of the crystalline lens and distance between the crystalline lens and the retina. In this new method we use the interferometric principle with a low coherence laser. The knowledge of these parameters is very important in order to supply the necessary data for the implant of intraocular lenes, in the cases of cataract. Besides of allow the diagnosis of the pathologies, which are characterized by their changes. The instrument used in the measurements is an ultrasonic biometer. However the resolution of this instrument is limited by the ocular tissue, which does not allow satisfactory echos in frequencies above 10 MHz. A variety of the techniques have been used in the last ten years in the order to establish a more accurate method. However most of the existing alternatives have been rejected due to operational complexity and high cost. The interferometric technique unites high resolution, operational simplicity and low cost. This can be concluded by the results obtained in this work, which demonstrate the great potentiality of the method for future in academic research or clinical diagnosis.
13

Bibliografia / -

Mariotti Filho, Gilberto Ronaldo 09 May 2016 (has links)
1: Por este livro passam outros. 1.1: Que são teses e dissertações senão livros? 1.2: O livro como um lugar, não um livro objeto, mas enquanto meio, programa. 2: Um corpo cujo contorno renega seu papel continente, sempre apontando sua razão de existir para além de seus limites. 3: Uma aproximação mimética, na medida em que se utiliza das possibilidades dispostas, categorias e ítens sobressalentes de um dispositivo opaco: a nota de rodapé, o registro fotográfico, a escrita formatada, a descrição como maneira, a pretensão de distância reflexiva, a objetividade anunciada em resumos. 4: O resgate suspeitoso de um mito de origem: a inserção da produção de arte no campo de erudição acadêmico sem que a primeira tivesse de se submeter ao segundo, (daí a noção de hóspede tomada de Duchamp, e como consequência sua dimensão fantasmática). 3. 1: Costurar tudo pela narrativa de um sujeito que a um só tempo analisa, olha e é visto, predicado. 5: Manipular os dados, e por isso, admitir a manipulação como método científico. Então afirmar tudo como num Tratado. 3.2: Foi dado um aviso: \"descrever muitas vezes nos desobriga de explicar\". Mas veio demasiado tarde: já se havia optado, como estratégia, pela distração. 5. 1: Propor a leitura, implicada em sua ficção, de uma linha de pesquisa e o que esta guarda de específico - quem sabe um manual, no sentido de que o livro pode-se ter em mãos. Mas nem vale fazer caso desta introdução. Resumo nenhum abre mão de sua pretensão de roteiro conciso que dispensa o que finge anunciar, o parodiar de mais uma Tese. / If the images give in to the association urge that gives them impulse, without the bond that condemns them to the shroud of ordinate thought. If writing renounces the imposed duty of servant to the ideas. If the footnotes leak through the page, allowing the book\'s layout to breath. If translation is confronted by treason, we assume this treason as creation and books cease to disguise as mere support for content: \"By this book elapse others. What are thesis and dissertations, but books?\" What would then be necessary to grant this Thesis, despite its uncommon format, any trace of respectability? In different languages, the political pretensions which are close to us sound like the resume of a fairy tale: \"In a far a way University, ranked first amidst those from Cruzeiro do Sul, there is a singular line of research, understood by us as a place among others...\" But it might come handy since we still defend fictional grounds as something proper of our condition. A matter of resistance to the appropriation faced by our writings to strange purposes -- although our purpose itself might be the strange one. To quote academics as writers, to quote Bataille`s Story of the Eye and, without notice, to grant the story a scientific status. To quote fiction itself and the wealthiest concepts in the most readable way, keeping its improper spelling: Concept. And thinking in a pragmatic way, how glamorous wouldn\'t be a well formulated monograph -- extended linearly and permeated with reflections proper to its medium -- named with an easily translatable title: Thesis as Site?
14

Bibliografia / -

Gilberto Ronaldo Mariotti Filho 09 May 2016 (has links)
1: Por este livro passam outros. 1.1: Que são teses e dissertações senão livros? 1.2: O livro como um lugar, não um livro objeto, mas enquanto meio, programa. 2: Um corpo cujo contorno renega seu papel continente, sempre apontando sua razão de existir para além de seus limites. 3: Uma aproximação mimética, na medida em que se utiliza das possibilidades dispostas, categorias e ítens sobressalentes de um dispositivo opaco: a nota de rodapé, o registro fotográfico, a escrita formatada, a descrição como maneira, a pretensão de distância reflexiva, a objetividade anunciada em resumos. 4: O resgate suspeitoso de um mito de origem: a inserção da produção de arte no campo de erudição acadêmico sem que a primeira tivesse de se submeter ao segundo, (daí a noção de hóspede tomada de Duchamp, e como consequência sua dimensão fantasmática). 3. 1: Costurar tudo pela narrativa de um sujeito que a um só tempo analisa, olha e é visto, predicado. 5: Manipular os dados, e por isso, admitir a manipulação como método científico. Então afirmar tudo como num Tratado. 3.2: Foi dado um aviso: \"descrever muitas vezes nos desobriga de explicar\". Mas veio demasiado tarde: já se havia optado, como estratégia, pela distração. 5. 1: Propor a leitura, implicada em sua ficção, de uma linha de pesquisa e o que esta guarda de específico - quem sabe um manual, no sentido de que o livro pode-se ter em mãos. Mas nem vale fazer caso desta introdução. Resumo nenhum abre mão de sua pretensão de roteiro conciso que dispensa o que finge anunciar, o parodiar de mais uma Tese. / If the images give in to the association urge that gives them impulse, without the bond that condemns them to the shroud of ordinate thought. If writing renounces the imposed duty of servant to the ideas. If the footnotes leak through the page, allowing the book\'s layout to breath. If translation is confronted by treason, we assume this treason as creation and books cease to disguise as mere support for content: \"By this book elapse others. What are thesis and dissertations, but books?\" What would then be necessary to grant this Thesis, despite its uncommon format, any trace of respectability? In different languages, the political pretensions which are close to us sound like the resume of a fairy tale: \"In a far a way University, ranked first amidst those from Cruzeiro do Sul, there is a singular line of research, understood by us as a place among others...\" But it might come handy since we still defend fictional grounds as something proper of our condition. A matter of resistance to the appropriation faced by our writings to strange purposes -- although our purpose itself might be the strange one. To quote academics as writers, to quote Bataille`s Story of the Eye and, without notice, to grant the story a scientific status. To quote fiction itself and the wealthiest concepts in the most readable way, keeping its improper spelling: Concept. And thinking in a pragmatic way, how glamorous wouldn\'t be a well formulated monograph -- extended linearly and permeated with reflections proper to its medium -- named with an easily translatable title: Thesis as Site?
15

Detecção automática de estruturas anatómicas em imagens digitais da retina

Cardoso, Filipe José Pinto de Lima January 2011 (has links)
Tese de mestrado integrado. Engenharia Electrotécnica e de Computadores. Faculdade de Engenharia. Universidade do Porto. 2010
16

Avaliação da integração de esferas de hidroxiapatita sintética e de polietileno poroso em cavidades evisceradas de coelhos /

Schellini, Silvana Artioli. January 1999 (has links)
Memorial (livre-docência) - Universidade Estadual Paulista, Faculdade de Medicina de Botucatu / Resumo: Para a recuperação da estética facial,há necessidade de reposição do volume orbitário perdido em decorrência de eviscerações ou enucleações. Este estudo foi realizado com os objetivos de avaliar comparativamente a biocompatibilidade e a manutenção do volume orbitário com o uso de esferas de hidroxiapatita sintética e de polietileno poroso, na reconstrução de cavidades evisceradas de coelhos. Métodos: Para isso foram utilizados 56 coelhos albinos, submetidos à evisceração do olho direito, com colocação de esferas de hidroxiapatita sintética (G1 - 28 animais) ou polietileno poroso (G2 - 28 animais).Quatro coelhos de cada grupo foram sacrificados em 7 momentos experimentais: 7, 15, 30, 60, 90, 120 e 180 dias após a evisceração. Após o sacrifício, o conteúdo da cavidade orbitária direita foi removido e seccionado na porção central em duas hemi-metades,uma das quais foi preparada para exame histopatológico; exame ultra-estrutural em microscópio eletrônico de varredura foi feito em dois animais de 7, 60 e 180 dias, de ambos os grupos experimentais. Resumo 118 Resultados: Observou-se aos 7 dias, tecido conjuntivo frouxo, constituído de células inflamatórias e hemáceas, em meio à rede de fibrina, principalmente na periferia da esfera de hidroxiapatita e chegando até ao centro da esfera de polietileno; a reação tecidual tornou-se mais densa com o passar do tempo. Decorridos 60 dias, observou-se em G1, início de metaplasia óssea que se acentuou ao longo do experimento. Em todos os momentos experimentais, a inflamação,predominantemente macrofágica, foi muito mais acentuada em G1.O volume da cavidade esclero-corneana foi melhor mantido em G2. Conclusão: a esfera de hidroxiapatita sintética provoca mais inflamação que a de polietileno poroso e é menos eficiente na manutenção do volume orbitário... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: In order to recovery the facial aesthetic , there is necessary to replace the orbital volume wich was lost because of enucleation or evisceration. The purpose of this study was to compare the tecidual reaction and corneoscleral cavity volume maintenance with the use of synthetic hydroxyapatite and porous polyethylene spheres in rabbits eviscerated cavities . Methods: There were used 56 white rabbits underwent a unilateral evisceration with placement of spheres of synthetic hydroxyapatite (G1-28 animals) and porous polyethylene (G2-28 animals). Four animals of each group were sacrificed in 7 experimental moments: 7, 15, 30, 60, 90, 120 and 180 days after the evisceration. After the sacrifice, the orbital content was removed, the wrapped up sphere was cross-sectional in it largest axis and prepared for histopatologic exam;scanning ultrastructure exam was performed in 2 animals of 7,60 and 180 days from both experimental groups. Results: Slack tecidual reaction with inflammatory cells and fibrin was observed mainly in the hydroxyapatite sphere periphery and reaching until the polyethylene sphere center Summary 120 7 days after the surgery. The tecidual reaction became denser and around 60 days bone metaplasia began in G1. In every observation moment, G1 had more inflammation than G2. The corneoscleral cavity area is better maintained in G2 than in G1 rabbits. Conclusion: The synthetic hydroxyapatite sphere provoked more inflammation than the porous polyethylene and it was less efficient in the maintenance of the cavity volume , what take us to consider the porous polyethylene superior to the synthetic hydroxyapatite in the anophthalmic cavity reconstruction.
17

Influência da rugosidade de superfície e ação de diferentes desinfetantes na formação de biofilme em resina acrílica para prótese ocular e sua biocompatibilidade em contato com células da conjuntiva humana /

Andreotti, Agda Marobo. January 2017 (has links)
Orientador: Daniela Micheline dos Santos / Banca: Marcela Filie Haddad / Banca: Cristiane Duque / Banca: Valentim Adelino Ricardo Barão / Banca: Sandra Helena Penha de Oliveira / Resumo: O controle da formação de biofilme é essencial para manter a saúde da cavidade anoftálmica dos portadores de prótese ocular. As propriedades físicas da resina acrílica, como a sua rugosidade, podem interferir na adesão de microrganismos nas próteses e na formação de biofilmes. Sendo assim, é necessário utilizar soluções de limpeza eficazes e que não causem irritação tecidual na conjuntiva ocular. O objetivo desse trabalho foi verificar a influência da rugosidade de superfície da resina acrílica utilizada na confecção de próteses oculares na formação de biofilme bacteriano, bem como avaliar a eficácia antimicrobiana e citotoxicidade de diferentes soluções para desinfecção de próteses oculares. Para a análise da rugosidade, corpos de prova de resina acrílica foram confeccionados e divididos em 5 grupos de acordo com a granulação de lixa de polimento utilizada: 120, 400, 800, 1200 e 1200S (lixa + sílica). A rugosidade dos corpos de prova foi mensurada por meio de perfilômetro e imagens de Microscopia de Força Atômica foram obtidas para cada grupo. O crescimento das espécies Staphylococcus aureus e Staphylococcus epidermidis sobre os corpos de prova foi avaliado após 4 e 24h, por meio da contagem das Unidades Formadoras de Colônia (UFC)/mL. O efeito dos seguintes tratamentos: soro fisiológico, sabão neutro, clorexidina 4%, pastilhas efervescentes Efferdent®, triclosan 1% e citronela sobre biofilme formado sobre os corpos de prova de resina acrílica também foi avaliado por meio da... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The control of biofilm formation is essential to maintain the health of anophthalmic cavity of ocular prosthesis wearers. The physical properties of the acrylic resin, such as surface roughness, may interfere with the adhesion of microorganisms to the prostheses. Therefore, it is necessary to use cleaning solutions that are effective and do not cause tissue irritation in ocular conjunctiva. The aim of this study was to verify the influence of surface roughness of the acrylic resin used in the preparation of ocular prosthesis in the formation of bacterial biofilm, as well as to evaluate the antimicrobial efficacy and cytotoxicity of different disinfectants in ocular prostheses. For roughness analysis, acrylic resin samples were prepared and divided into 5 groups according to the granulation of polishing sandpaper used: 120, 400, 800, 1200 and 1200S (sandpaper + silica). The roughness of the samples was measured using a profilometer and Atomic Force Microscopy images were obtained for each group. The microbial growth for Staphylococcus aureus and Staphylococcus epidermidis on the samples was evaluated after 4 and 24 h by counting the Colony Forming Units (CFU)/mL. The effect of the following solutions was also evaluated by CFU/mL: non treated group (immersed in saline solution), neutral soap, 4% chlorhexidine, Efferdent® effervescent tablets, 1% triclosan and citronella. The cytotoxicity of the solutions was evaluated by MTT and Neutral Red after treating the samples daily for ... (Complete abstract click electronic access below) / Doutor
18

Análise in vitro da proliferação celular e produção de mediadores inflamatórios por células da conjuntiva estimuladas por materiais utilizados na confecção de próteses oculares /

Silva, Emily Vivianne Freitas da. January 2015 (has links)
Orientador: Marcelo Coelho Goiato / Coorientador: Sandra Helena Penha de Oliveira / Banca: Aimée Guiotti / Banca: Rafael Consani / Resumo: A prótese ocular é utilizada para a reabilitação estética e funcional da ausência ocular. O conhecimento da sua biocompatibilidade é importante para a utilização sem reações danosas aos usuários. O objetivo neste estudo foi avaliar a citotoxicidade de materiais utilizados na confecção de próteses oculares, por meio da análise da proliferação celular e da produção de citocinas pró-inflamatórias e de proteínas de matriz extracelular por células da conjuntiva humana. Inicialmente, foi analisada a influência de diferentes períodos de formação e de exposição dos extratos de resina acrílica branca (N1), termopolimerizada em água aquecida, sobre culturas de células da conjuntiva. Foram confeccionados 24 corpos de prova em resina, sendo 12 para cada período de exposição de células da conjuntiva aos extratos da resina testada (24 e 72 horas). Após a formação dos extratos por 24, 48 e 72 horas de imersão em meio de cultura e, 24 horas em água seguido de 24 horas de imersão em meio, os ensaios propostos foram realizados (n=3). Em seguida, foi avaliado o efeito citotóxico de diferentes métodos de polimerização de resina acrílica N1 em células da conjuntiva. Foram confeccionados 9 corpos de prova em resina (n=3), termopolimerizados em água aquecida, por energia de microondas ou ativados quimicamente, utilizados para a formação dos extratos dessas resinas. Os extratos foram obtidos após 72 horas de imersão dos corpos de prova em meio de cultura e, então, expostos às células da conjuntiva por 72 horas para a realização dos ensaios propostos. Adicionalmente, foi analisada a influência da presença do pigmento acrílico na confecção da prótese de resina acrílica N1, termopolimerizada em água aquecida... / Abstract: Ocular prosthesis is a treatment option for esthetical and functional rehabilitation of ocular absence. The knowledge of ocular prosthesis material's biocompatibility is important to ensure a safe use in patients. The aim of this study was to evaluate the cytotoxic effect of ocular prosthesis materials, through the analysis of the cell proliferation, and the production of proinflammatory cytokines and extracellular matrix proteins by a human conjunctival cell line. Initially, the influence of different preparation and exposition periods of eluates from heat-polymerized ocular prosthesis N1 color acrylic resin in human conjunctival cell line was evaluated. A total of 24 acrylic resin samples were manufactured and divided into 2 groups, according to the eluate exposition period to conjunctival cell line (24 and 72 hours). Eluates corresponding to 24, 48 and 72 hours of resin sample immersion in medium and, 24 hours of resin sample immersion in water followed by 24 hours of immersion in medium, were prepared (n=3) for the proposed tests. Then, the cytotoxic effect of different polymerization methods of ocular prosthesis N1 color acrylic resin was analyzed. A total of 9 acrylic resin samples were manufactured (n=3), according to the polymerization method: heat-polymerization in water bath, polymerization by microwave energy and auto-polymerization. Eluates corresponding to 72 hours of resin sample immersion in medium were prepared for proposed tests and exposed to conjunctival cell line for 72 hours. Additionally, the influence of pigment incorporation on the cytotoxicity of heat-polymerized ocular prosthesis N1 color acrylic resin was evaluated... / Mestre
19

Avaliação clínica e microbiológica da secreção conjuntival em usúarios de prótese ocular em resina acrílica

Neves, Ana Christina Claro [UNESP] 14 June 2000 (has links) (PDF)
Made available in DSpace on 2018-07-27T18:25:54Z (GMT). No. of bitstreams: 0 Previous issue date: 2000-06-14. Added 1 bitstream(s) on 2018-07-27T18:29:53Z : No. of bitstreams: 1 000127134.pdf: 1653433 bytes, checksum: a86ba2adfc63a2d23fea7089b1555de7 (MD5) / Este trabalho objetivou avaliar a microbiota bacteriana e fúngica das cavidades anoftálmicas, próteses oculares e olhos contralaterais de 43 usuários de prótese ocular em resina acrílica, unilateral, e relacionar a quantidade de secreção conjuntival presente nessas cavidades com a microbiota conjuntival, frequência de limpeza, tempo de uso e tempo decorrido desde o último polimento da prótese. Todos os pacientes apresentavam secreção conjuntival e microbiota Gram positiva nas cavidades anoftálmicas, Os microrganismos mais frequentemente isolados das 43 cavidades anoftálmicas, por ordem decrescente de freqüência, foram: Staphyfococcus coagulase negativos, Staphylococcus aureus, Candída albicans, Proteus mirabilis, Citrobacter koseriana, Streptococcus pyogenes, Pseudomonas aeruginosa, Enterobacter sakazakii e Enterobacter aerogenes. Microbiota Gram negativa foi isolada de oito cavidades e fúngica, de três. O estudo estatístico dos dados evidenciou relação não significativa entre a quantidade de secreção conjuntival e a presença de microbiota Gram negativa• nas cavidades; e entre a quantidade de secreção conjuntival e a frequência de limpeza da prótese ocular. Correlação, estatisticamente significativa, foi constatada entre a quantidade de secreção conjuntiva! e o tempo de uso e o tempo decorrido desde o último polimento da prótese / The purpose of this work was to evaluate the bacterial and fungic microbiota of the anophthalmic sockets, ocular prosthesis and fellow eyes of forty three acrylic resin prosthesís carrying patients, and thereby relate the amount of conjunctival discharge to the presence of organisms, frequency of prosthesis cleaning, time of use and elapsed time since the last prosthesis polishing. All patients showed conjunctival discharge and Gram positive organisms in the anophthalmic sockets. The predominant organisms in the anophthalmic sockets were Staphylococcus coagulase negative, Staphylococcus aureus, Candida albicans, Proteus mirabilis, Citrobacter koseriana, Streptococcus pyogenes, Pseudomonas aeruginosa, Enterobacter sakazakii e Enterobacter aerogenes. Gram negative bacteria were found in eight anophthalmic sockets and fungi in three. No relation was found between the amount of the conjunctival discharge and the presence of Gram negative bacteria in the anophthalmic socket, nor with the frequency of prosthesis cleaning. However, there was a significant relation between the amount of conjunctival discharge and time of prosthesis use, as well as time elapsed since the last prosthesis polishing
20

Análise da estabilidade de cor de botões de íris artificiais obtidos por diferentes técnicas e após o envelhecimento acelerado /

Bannwart, Lisiane Cristina. January 2012 (has links)
Orientador: Marcelo Coelho Goiato / Co-orientador: Daniela Micheline dos Santos / Banca: Mário Alexandre Coelho Sinhoreti / Banca: Eduardo Piza Pellizzer / Resumo: As próteses oculares são responsáveis pela recuperação da estética e auto-estima do usuário. As técnicas existentes para a confecção da prótese ocular devem resultar em íris artificiais perfeitamente estéticas com conseqüente dissimulação do defeito facial. Dessa forma, este estudo tem como propósito verificar a alteração de cor do botão de íris artificial entre diferentes técnicas após a polimerização e o envelhecimento acelerado. Foram confeccionadas 60 amostras simulando próteses oculares distribuídas em grupos (n=10) de acordo com a técnica utilizada, sendo: PE: técnica convencional sem verniz, PEV: técnica convencional com verniz, CA: técnica com calota pré-fabricada sem verniz, CAV: técnica com calota pré-fabricada com verniz, PI: técnica da pintura invertida sem verniz, PIV: técnica da pintura invertida com verniz. A leitura de cor foi realizada por meio de um espectrofotômetro de reflexão ultravioleta visível utilizando o sistema CIE L*a*b*, antes e após polimerização, e após 252, 504 e 1008 de envelhecimento acelerado. Os dados obtidos foram submetidos à análise de variância (ANOVA), e teste de Tukey (p<0,05). O teste de cor mostrou que após polimerização e envelhecimento acelerado todas as amostras apresentaram alteração significativa da cor, porém, as amostras com verniz protetor de tinta tiveram menor alteração em todos os períodos analisados. / Abstract: Ocular prostheses are responsible not only for the recovery of aesthetic but also for the self-esteem of the anophthalmic patient. The techniques used to fabricate ocular prosthesis should result in artificial iris with adequate aesthetic and natural appearance. When such characteristics are not achieved, the fabrication of new prosthesis is indicated even in the presence of good fit of the old prosthesis. Additionally, the color instability of iris is the most relevant factor that affects the longevity of ocular prosthesis, and is related to the polymerization process of the acrylic resin and its clinical use over time. Therefore, the present study investigated the color alteration of artificial iris buttons obtained by different techniques after polymerization and accelerated aging. A total of 60 samples simulating an ocular prosthesis were fabricated and divided into groups (n=10) according to the technique used: PE - conventional technique without varnish; PEV - conventional technique with varnish; CA - Prefabricated cap technique without varnish; CAV - Prefabricated cap technique with varnished; PI - Reverse painting technique without varnish; PIV - Reverse painting technique with varnish. Color measurements were performed by using a visible ultraviolet reflection spectrophotometer with the CIE L*a*b* system, before and after polymerization, and after 252, 504 and 1008 hours of accelerated aging. Data were submitted to analysis of variance (ANOVA) and Tukey test (p<.05). After polymerization and accelerated aging periods all samples exhibited statistically color alteration; however, the varnished samples had lower color change for all periods. / Mestre

Page generated in 0.0222 seconds