• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 16
  • 9
  • 2
  • Tagged with
  • 25
  • 25
  • 19
  • 13
  • 11
  • 9
  • 8
  • 7
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Tomographie optique de fluorescence dans les milieux diffusants : apport de l'information temporelle / Fluorescence diffuse optical tomography : benefits of using the time-resolved modality

Ducros, Nicolas 06 October 2009 (has links)
La tomographie optique diffuse de fluorescence permet la reconstruction tridimensionnelle de fluorophores présents dans un tissu biologique. La modalité la plus simple de cette technique repose sur une illumination continue du milieu et s'intéresse aux mesures d'atténuation du faisceau incident en différentes positions. En raison de la forte diffusion des tissus, la modalité continue souffre d'une faible résolution en profondeur.On considère aujourd'hui que la modalité résolue en temps, qui fournit pour chaque photon détecté son temps de vol, permettrait l'étude de tissus plus épais, ouvrant ainsi la porte à des applications cliniques. L'objet de cette thèse est de chercher comment tirer profit de l'information temporelle et de quantifier son apport par rapport à la modalité continue.La tomographie optique diffuse de fluorescence est un problème inverse mal conditionné. Dans un contexte où tout écart au modèle doit être limité, nous nous intéressons tout d'abord au modèle direct et montrons que la densité de photons est un modèle satisfaisant de la quantité expérimentalement mesurée. Nous passons ensuite au crible la méthode de reconstruction fondée sur l'exploitation des moments temporels des mesures. Étudiant théoriquement les propriétés des moments, nous montrons que cette approche nécessite, pour s'avérer intéressante, la détection d'un nombre élevé de photons. Nous introduisons enfin une nouvelle approche permettant d'exploiter l'information temporelle pour un nombre de photons plus limité. Cette approche, reposant sur une transformation en ondelettes des mesures, offre une qualité de reconstruction accrue par rapport à celle offerte par l'approche des moments. / Fluorescence diffuse optical tomography enables the three-dimensional reconstruction of fluorescence markers injected within a biological tissue, with light in the near infrared range. The simple continuous modality uses steady excitation light and operates from the measurements at different positions of the attenuation of the incident beam. This technique is low-cost, non-ionizing, and easy to handle, but subject to low resolution for thick tissues due to diffusion. Hopefully, the time-resolved modality, which provides the time of flight of any detected photon, could overcome this limitation and pave the way to clinical applications. This thesis aims at determining the best way to exploit the time resolved information and at quantifying the advantages of this modality over the standard continuous wave one.Model deviations must be carefully limited when ill-posed problems as fluorescence diffuse optical tomography are considered. As a result, we have first addressed the modelling part of the problem. We have shown that the photons density models to good approximation the measurable quantity that is the quantity measured by an actual acquisition set-up. Then, the moment-based reconstruction scheme has been thoroughly evaluated by means of a theoretical analysis of the moments’ properties. It was found that the moment-based approach requires high photon counts to be profitable compared to the continuous wave modality. Last, a novel wavelet-based approach, which enables an improved reconstruction quality, has been introduced. This approach has shown good ability to exploit the temporal information at lower photon counts.
12

Tomographie optique diffuse : une approche résolue en temps pour les mesures en réflectance à courtes distances entre sources et détecteurs / Diffuse optical tomography : a time-resolved approach for reflectance measurements at short source-detector separation

Puszka, Agathe 05 December 2013 (has links)
La tomographie optique diffuse (TOD) est une technique d'imagerie médicale émergente utilisant la lumière proche infrarouge pour sonder les tissus biologiques. A partir de mesures non-invasives, cette technique permet d'obtenir les cartes en trois dimensions des coefficients d'absorption et de diffusion à l'intérieur des organes. Avec une approche multi-spectrale, la distribution spatiale des chromophores endogènes (hémoglobine, eau) peut aussi être obtenue. Pour certaines applications cliniques, il est souhaitable d'effectuer les mesures de TOD avec une sonde compacte qui regroupe tous les couples source-détecteur. Cependant, dans cette configuration, la sensibilité en profondeur est un défi majeur. Dans le cadre de cette thèse, nous proposons d'adresser ce challenge en utilisant des mesures résolues en temps. Une approche résolue en temps est développée pour optimiser la TOD dans le cas des mesures de réflectance à faibles distances source-détecteur. Cette approche inclut des aspects méthodologiques concernant le traitement des mesures résolues en temps par des algorithmes de TOD basés sur la transformée de Mellin-Laplace. Cette approche comporte aussi un volet instrumental qui consiste à optimiser la chaîne de détection sur deux points précis pour améliorer la détection et la localisation de contraste d'absorption en profondeur dans les milieux diffusants. Tout d'abord, l'impact de la réponse temporelle du détecteur est étudié avec des détecteurs de photons uniques disponibles dans le commerce (photomultiplicateurs classiques et hybrides). Dans un second temps, l'augmentation de la profondeur sondée avec de nouveaux détecteurs de photons uniques, les fast-gated single-photon avalanche diodes, est explorée au cours d'une collaboration avec le Politecnico de Milan. Pour finir, une étude illustre les performances de l'approche proposée en termes de résolution spatiale en profondeur pour différents arrangements des sources et détecteurs dans une sonde optique. Des sondes optiques dont la largeur est limitée à quelques centimètres ouvrent la voie à de nouvelles applications cliniques pour la TOD. Ces sondes peuvent accéder à des organes internes comme la prostate ou faciliter les examens médicaux sur des organes externes comme le sein ou le cerveau. / Diffuse optical tomography (DOT) is an emerging medical imaging technique using near-infrared light to probe biological tissues. This technique can retrieve three-dimensional maps of absorption and scattering coefficients inside organs from non-invasive measurements. With a multispectral approach, the spatial distribution of endogenous chromophores (hemoglobin, water) can even be obtained. For some clinical applications, it is desirable to carry out the measurements for DOT with a compact probe including all sources and detectors. However, the depth sensitivity is a real challenge in this configuration. We propose to tackle this challenge by using time-resolved measurements. A time-resolved approach is developed to perform DOT with reflectance measurements at short source-detector separation. This approach involves methodological aspects including the processing of time-resolved signals by DOT algorithms based on the Mellin-Laplace transform. Then, this approach consists in optimizing the detection chain on two aspects for enhancing the detection and localization of absorption contrast in depth in diffusive media. First, the impact of the temporal response of the detector is studied with commercially available single-photon detectors (classical and hybrid photomultipliers). Second, the enhancements in probed depth permitted with fast-gated single-photon avalanche diodes are explored in a joint work with the Politecnico di Milano. To finish, a study is carried out to illustrate the performance of the proposed approach with respect to spatial resolution in depth for different configurations of sources and detectors in the optical probe. Probes with a width limited to a few centimeters open the gate to multiple clinical interests. They could access intern organs like the prostate or facilitate the measurements on extern organs like the breast or the brain.
13

Scanner pour tomographie optique diffuse sans contact à canaux de détection dans le domaine temporel à deux bandes de longueur d'onde pour imagerie intrinsèque et par fluorescence sur petit animal

Lapointe, Eric January 2011 (has links)
Ce mémoire décrit le développement opto-mécanique et électro-mécanique de la 2ième version du scanner TomOptUS pour tomographie optique diffuse (TOD).Ce scanner est destiné à l'imagerie moléculaire 3D de l'intérieur d'un petit animal. Les buts de la TOD sont : 1) d'obtenir la distribution spatiale des coefficients d'absorption ([mu][indice inférieur a]) et de diffusion ([mu][indice inférieur s]) dans les tissus biologiques (imagerie intrinsèque) et 2) de localiser des agents fluorescents injectés et à suivre leur distribution spatiale (imagerie par fluorescence). La TOD sur petit animal est d'un grand intérêt en pharmacologie et en oncologie pour l'étiquetage de médicaments afin de suivre leur progression, pour suivre l'évolution d'une pathologie sous traitement sur un même individu, ou pour repérer des cellules cancéreuses par marquage des protéines membranaires qu'elles expriment. La diffusion de la lumière dans les tissus biologiques est le plus grand obstacle en TOD. Les mesures en régime continu ne permettent pas de distinguer les photons détectés selon le degré de diffusion qu'ils subissent. La diffusion mène à une perte d'information quant à la trajectoire suivie par les photons. La détection résolue en temps permet de garder une partie de cette information. Le scanner TomOptUS utilise un système ultra-rapide de comptage de photons corrélé en temps et des tubes photomultiplicateurs pour mesurer la distribution temporelle de pulses lumineux transmis et/ou rétrodiffusés dans le sujet à imager suite à l'illumination à l'aide d'impulsions laser ultra-brèves. La 2 ième version du scanner est un système multicanal à géométrie annulaire sur 360 [degrés] autour du sujet. Il est muni de 7 canaux de détection optique permettant l'acquisition simultanée de données tomographiques dans deux bandes de longueurs d'onde (intrinsèque et fluorescence). L'acquisition des données est automatisée par ordinateur.Ce scanner a l'avantage d'effectuer des mesures sans contact avec le sujet. Ceci facilite l'acquisition des données et permettra éventuellement de le combiner à d'autres modalités d'imagerie médicale sans contact (tomographie d'émission par positrons, tomodentométrie [i.e. tomodensitométrie] ou imagerie par résonance magnétique) pour réaliser des séances d'imagerie multimodales. Le scanner est aussi équipé d'un système de vision numérique stéréo à 2 caméras permettant de mesurer la surface externe du sujet en 3D. Les mesures tomographiques et de surface se font simultanément en utilisant le faisceau laser incident sur le sujet. On présente des résultats de localisation d'un nombre a priori inconnu d'inclusions fluorescentes ponctuelles dans une mire (ou fantôme) absorbante et diffusante. L'algorithme de localisation repose sur la mesure des temps d'arrivée des premiers photons à différentes positions angulaires autour du sujet. Ceci requiert une résolution temporelle très élevée dans la détection des photons, une très grande synchronisation des différents canaux de détection et une grande stabilité dans la détection des signaux optiques. L'architecture du scanner ainsi qu'une méthode de calibration élaborée dans le cadre des présents travaux permettent d'atteindre de telles performances. On présente également des résultats préliminaires de l'effet d'un milieu hétérogène sur le temps de vol des photons.
14

Mise en oeuvre d'un mode d'imagerie par transillumination et détection multi-vue à ultra-faible bruit dans l'imageur QOS[indice supérieur TM] pour imagerie moléculaire optique sur petit animal / Implementation of transillumination mode and ultra-low noise multi-view detection in the QOS[superscript TM] for small animal optical molecular imaging

Zarif Yussefian, Nikta January 2014 (has links)
La tomographie optique diffuse (TOD) est une technique d’imagerie médicale relativement récente qui utilise la lumière dans le proche infrarouge pour acquérir des images in vivo de façon non invasive. Cette technique est en utilisation croissante par de nombreux chercheurs et biologistes et plusieurs équipes dans le monde travaillent sur le développement de scanners par TOD y compris notre groupe de recherche (groupe TomOptUS). Le Centre d’imagerie moléculaire de Sherbrooke dispose d’un appareil pour imagerie optique sur petit animal développé par la compagnie Quidd, soit le QOS (Quidd Optical imaging System). Cet appareil est utilisé par des biologistes et chercheurs pour diverses études précliniques sur modèles animaux (souris) de maladies humaines comme le cancer. Le QOS est entièrement contrôlé par ordinateur à l’aide d’un logiciel sophistiqué (le QOSoft) qui permet d’obtenir des images en fluorescence et en bioluminescence. Il est toutefois limité en ne permettant d’acquérir que des images planaires de la lumière sortant d’un animal ; il ne permet pas la tomographie, à savoir obtenir des images tridimensionnelles (3D) des sources fluorescentes ou bioluminescentes situées en profondeur à l’intérieur de l’animal. Bien que le QOS offre une grande flexibilité en terme d’angle d’acquisition d’images autour de l’animal avec sa caméra montée sur un bras rotatif, il a une sensibilité limitée pour de l’imagerie en profondeur, notamment parce qu’il fonctionne en mode épiillumination (détection de la lumière du même côté que l’injection de la lumière excitatrice dans l’animal) et aussi à cause de la sensibilité limitée de sa caméra. Afin d’augmenter les capacités tomographiques et la sensibilité du QOS, ainsi que le contraste des images qu’il fournit, le présent projet propose des développements logiciels intégrés au QOSoft. Ces ajouts logiciels au niveau du contrôle d’instrumentation et de l’interface graphique permettent d’intégrer une caméra EMCCD à ultra-haute sensibilité et ultra-faible bruit pour remplacer la caméra CCD refroidie existante ainsi qu’un module d’illumination laser rotatif. Ce module d’illumination, développé par le groupe TomOptUS, permet l’imagerie en mode transillumination ainsi que toutes les configurations intermédiaires jusqu’à l’épi-illumination. Ce module permet en outre d’injecter une densité de puissance lumineuse supérieure à celle possible avec la configuration actuelle du QOS. Le QOS et son logiciel mis à jour avec les ajouts faisant l’objet du présent projet sont validés par des expériences de fluorescence et de bioluminescence sur fantômes et animaux vivants.
15

Développement d’un système de spectroscopie infrarouge résolue temporellement pour la quantification des concentrations d’hémoglobine cérébrale

Leclerc, Paul-Olivier 11 1900 (has links)
L’étude du cerveau humain est un domaine en plein essor et les techniques non-invasives de l’étudier sont très prometteuses. Afin de l’étudier de manière non-invasive, notre laboratoire utilise principalement l’imagerie par résonance magnétique fonctionnelle (IRMf) et l’imagerie optique diffuse (IOD) continue pour mesurer et localiser l’activité cérébrale induite par une tâche visuelle, cognitive ou motrice. Le signal de ces deux techniques repose, entre autres, sur les concentrations d’hémoglobine cérébrale à cause du couplage qui existe entre l’activité neuronale et le flux sanguin local dans le cerveau. Pour être en mesure de comparer les deux signaux (et éventuellement calibrer le signal d’IRMf par l’IOD), où chaque signal est relatif à son propre niveau de base physiologique inconnu, une nouvelle technique ayant la capacité de mesurer le niveau de base physiologique est nécessaire. Cette nouvelle technique est l’IOD résolue temporellement qui permet d’estimer les concentrations d’hémoglobine cérébrale. Ce nouveau système permet donc de quantifier le niveau de base physiologique en termes de concentrations d’hémoglobine cérébrale absolue. L’objectif général de ma maîtrise était de développer un tel système afin de l’utiliser dans une large étude portant sur la condition cardiovasculaire, le vieillissement, la neuroimagerie ainsi que les performances cognitives. Il a fallu tout d’abord construire le système, le caractériser puis valider les résultats avant de pouvoir l’utiliser sur les sujets de recherche. La validation s’est premièrement réalisée sur des fantômes homogènes ainsi qu’hétérogènes (deux couches) qui ont été développés. La validation des concentrations d’hémoglobine cérébrale a été réalisée via une tâche cognitive et appuyée par les tests sanguins des sujets de recherche. Finalement, on présente les résultats obtenus dans une large étude employant le système d’IOD résolue temporellement en se concentrant sur les différences reliées au vieillissement. / Our understanding of the functional organization of the human brain has been greatly influenced by the development of new medical imaging techniques. Pr. Hoge’s research has focused on the use of functional magnetic resonance imaging (fMRI) and continuous diffuse optical imaging (DOI) for non-invasive localization and quantification of brain activity associated with behavioral stimuli or tasks (e.g. cognitive, motor or visual). The respective signals of both techniques are based on cerebral haemoglobin concentrations because of the coupling that exists between neuronal activity and cerebral blood flow. Relating BOLD fMRI signals with those acquired using DOI has been complicated by the fact that fMRI yields fractional change values, while the majority of DOI methods have provided absolute changes from an unknown baseline. To address this, we adopted a newer technique known as time-resolved DOI, which allows absolute quantification of cerebral haemoglobin concentrations. Time-resolved DOI thus has the capacity to quantify the subject’s resting hemoglobin concentrations in absolute micromolar units. The main objective of my masters’ project was to implement and optimize a time-resolved DOI system for use in a large study exploring the links between cardiovascular fitness, aging, neuroimaging markers, and cognitive performance. In this thesis we describe the fabrication of the system, followed by its characterisation and validation using solid optical phantoms (homogeneous and heterogeneous) developed for this purpose. Haemoglobin concentrations obtained non-invasively with the system are validated against blood draws, while the sensitivity to variations in concentration are assessed during a cognitive task. Finally, we present the results of a large study in which the time-resolved DOI system was used to characterize age-related vascular changes in the brain.
16

Tomographie optique de fluorescence dans les milieux diffusants : apport de l'information temporelle

Ducros, Nicolas 06 October 2009 (has links) (PDF)
La tomographie optique diffuse de fluorescence permet la reconstruction tridimensionnelle de fluorophores présents dans un tissu biologique. La modalité la plus simple de cette technique repose sur une illumination continue du milieu et s'intéresse aux mesures d'atténuation du faisceau incident en différentes positions. En raison de la forte diffusion des tissus, la modalité continue souffre d'une faible résolution en profondeur.On considère aujourd'hui que la modalité résolue en temps, qui fournit pour chaque photon détecté son temps de vol, permettrait l'étude de tissus plus épais, ouvrant ainsi la porte à des applications cliniques. L'objet de cette thèse est de chercher comment tirer profit de l'information temporelle et de quantifier son apport par rapport à la modalité continue.La tomographie optique diffuse de fluorescence est un problème inverse mal conditionné. Dans un contexte où tout écart au modèle doit être limité, nous nous intéressons tout d'abord au modèle direct et montrons que la densité de photons est un modèle satisfaisant de la quantité expérimentalement mesurée. Nous passons ensuite au crible la méthode de reconstruction fondée sur l'exploitation des moments temporels des mesures. Étudiant théoriquement les propriétés des moments, nous montrons que cette approche nécessite, pour s'avérer intéressante, la détection d'un nombre élevé de photons. Nous introduisons enfin une nouvelle approche permettant d'exploiter l'information temporelle pour un nombre de photons plus limité. Cette approche, reposant sur une transformation en ondelettes des mesures, offre une qualité de reconstruction accrue par rapport à celle offerte par l'approche des moments.
17

Recalage d'image de la tomographie optique diffuse de fluorescence (fDOT) et la tomographie par émission de positons (TEP) et le développement de tomographie optique en multi-angle

Tong, Xiao 24 October 2012 (has links) (PDF)
Ce travail de thèse concerne le traitement d'image fDOT (fDOT pour fluorescence diffuse optical tomography) suit vers deux axes. Le recalage d'images fDOT à l'aide de l'imagerie TEP (tomographie par émission de positons) et l'amélioration des reconstructions fDOT à l'aide de miroirs pour collecter des projections complémentaires. Il est présenté en deux parties : Dans la première partie, une méthode automatique pour recaler les images de fDOT avec les images de Tomographie par Emission de Positons (TEP) développée dans le but de corréler l'ensemble des informations issues de chaque modalité. Cette méthode de recalage est basée sur une détection automatique de marqueurs fiduciaires présents dans les deux modalités. La particularité de cette méthode est l'utilisation de l'image de surface obtenue en fDOT, qui sert à identifier la position en Z des marqueurs fiduciaires dans les images optiques. Nous avons testé cette méthode sur un modèle de souris porteuses de xénogreffes de tumeurs de cellules cancéreuses MEN2A qui imitent un carcinome thyroïdien médullaire humain, après une double injection de traceur radioactif : [18F]2-fluoro-2-Deoxy-D-glucose (FDG) pour l'imagerie TEP et un traceur optique d'infrarouge fluorescent, le Sentidye. Grâce à la précision de notre méthode, nous arrivons à démontrer que le signal Sentidye est présent à la fois dans la tumeur et les vaisseaux environnants [1]. La qualité des images fDOT est dégradée selon l'axe Z du fait d'un nombre limité de projections pour la reconstruction. Dans la deuxième partie, le travail s'est orienté vers une nouvelle méthode de reconstruction d'images fDOT à partir d'un nouveau système d'acquisition multi-angulaire avec deux miroirs placés de chaque côté de l'animal. Ce travail a été mené en collaboration avec le département CS d'University College London (UCL), partenaire du projet Européen FMT-XCT. Le logiciel TOAST développé par cette équipe a été utilisé comme source pour l'algorithme de reconstruction, et modifié pour s'adapter à notre problématique. Après plusieurs essais concernant l'ajustement des paramètres du programme, nous avons appliqué cette méthode sur un fantôme réaliste des tissus biologiques et chez la souris. Les résultats montrent une amélioration de l'image reconstruite d'un fantôme semi-cylindrique et de l'image de rein chez la souris, pour lesquelles la méthode des miroirs est supérieure à la méthode classique sans miroir. Malgré tout, nous avons observé que les résultats étaient très sensibles à certains paramètres, d'où une performance de reconstruction variable d'un cas à l'autre. Les perspectives futures concernent l'optimisation des paramètres afin de généraliser l'approche multi-angle.
18

Développement d’un système de spectroscopie infrarouge résolue temporellement pour la quantification des concentrations d’hémoglobine cérébrale

Leclerc, Paul-Olivier 11 1900 (has links)
L’étude du cerveau humain est un domaine en plein essor et les techniques non-invasives de l’étudier sont très prometteuses. Afin de l’étudier de manière non-invasive, notre laboratoire utilise principalement l’imagerie par résonance magnétique fonctionnelle (IRMf) et l’imagerie optique diffuse (IOD) continue pour mesurer et localiser l’activité cérébrale induite par une tâche visuelle, cognitive ou motrice. Le signal de ces deux techniques repose, entre autres, sur les concentrations d’hémoglobine cérébrale à cause du couplage qui existe entre l’activité neuronale et le flux sanguin local dans le cerveau. Pour être en mesure de comparer les deux signaux (et éventuellement calibrer le signal d’IRMf par l’IOD), où chaque signal est relatif à son propre niveau de base physiologique inconnu, une nouvelle technique ayant la capacité de mesurer le niveau de base physiologique est nécessaire. Cette nouvelle technique est l’IOD résolue temporellement qui permet d’estimer les concentrations d’hémoglobine cérébrale. Ce nouveau système permet donc de quantifier le niveau de base physiologique en termes de concentrations d’hémoglobine cérébrale absolue. L’objectif général de ma maîtrise était de développer un tel système afin de l’utiliser dans une large étude portant sur la condition cardiovasculaire, le vieillissement, la neuroimagerie ainsi que les performances cognitives. Il a fallu tout d’abord construire le système, le caractériser puis valider les résultats avant de pouvoir l’utiliser sur les sujets de recherche. La validation s’est premièrement réalisée sur des fantômes homogènes ainsi qu’hétérogènes (deux couches) qui ont été développés. La validation des concentrations d’hémoglobine cérébrale a été réalisée via une tâche cognitive et appuyée par les tests sanguins des sujets de recherche. Finalement, on présente les résultats obtenus dans une large étude employant le système d’IOD résolue temporellement en se concentrant sur les différences reliées au vieillissement. / Our understanding of the functional organization of the human brain has been greatly influenced by the development of new medical imaging techniques. Pr. Hoge’s research has focused on the use of functional magnetic resonance imaging (fMRI) and continuous diffuse optical imaging (DOI) for non-invasive localization and quantification of brain activity associated with behavioral stimuli or tasks (e.g. cognitive, motor or visual). The respective signals of both techniques are based on cerebral haemoglobin concentrations because of the coupling that exists between neuronal activity and cerebral blood flow. Relating BOLD fMRI signals with those acquired using DOI has been complicated by the fact that fMRI yields fractional change values, while the majority of DOI methods have provided absolute changes from an unknown baseline. To address this, we adopted a newer technique known as time-resolved DOI, which allows absolute quantification of cerebral haemoglobin concentrations. Time-resolved DOI thus has the capacity to quantify the subject’s resting hemoglobin concentrations in absolute micromolar units. The main objective of my masters’ project was to implement and optimize a time-resolved DOI system for use in a large study exploring the links between cardiovascular fitness, aging, neuroimaging markers, and cognitive performance. In this thesis we describe the fabrication of the system, followed by its characterisation and validation using solid optical phantoms (homogeneous and heterogeneous) developed for this purpose. Haemoglobin concentrations obtained non-invasively with the system are validated against blood draws, while the sensitivity to variations in concentration are assessed during a cognitive task. Finally, we present the results of a large study in which the time-resolved DOI system was used to characterize age-related vascular changes in the brain.
19

Tomographie optique diffuse multispectrale résolue en temps / Multispectral time-resolved diffuse optical tomography

Zouaoui, Judy 21 November 2016 (has links)
La possibilité de déterminer précisément et de quantifier la composition des milieux biologiques est un défi pour l'imagerie médicale qui permettrait de diagnostiquer certaines maladies ou de mieux étudier les processus physiologiques. La tomographie optique diffuse (DOT) est une technique d'imagerie attrayante qui permet de façon non invasive, non-ionisante et potentiellement avec une grande spécificité de sonder les milieux en profondeur en utilisant la lumière dans le proche infrarouge et de reconstruire en trois dimensions leur composition. Pour obtenir les caractéristiques des chromophores endogènes (oxy- et désoxy-hémoglobine) enfouis dans un milieu très diffusant, une instrumentation optique dans le domaine temporel et multi-longueurs d'onde combinée à un algorithme de reconstruction en trois dimensions a été développée. Des mesures expérimentales ont été menées en géométrie de réflectance en éclairant avec un laser picoseconde un milieu perturbé (contenant une hétérogénéité) et en récupérant, pour plusieurs longueurs d'onde et multi-positions, la lumière rétrodiffusée via deux fibres optiques connectées à deux détecteurs dédiés et couplés à un système de comptage de photon unique. Le traitement des données de ces mesures résolues en temps a été réalisé en supposant que la propagation de la lumière est gouvernée par l'approximation de la diffusion et en utilisant une méthode basée sur la transformée de Mellin-Laplace. Des simulations et des expériences sur une gamme de milieux imitant les milieux biologiques ont démontré que cette technique médicale a le potentiel pour donner des images médicales quantitatives. Nous avons montré que l'on peut déterminer correctement la composition d'objets à 10 mm de profondeur absorbant faiblement. Pour de plus fortes profondeurs et des absorptions plus élevées, la valeur du coefficient d'absorption ou de la concentration est sous-estimée. En outre, l'imagerie multimodale apporte des améliorations dans la précision de la quantification en profondeur et donc peut être une bonne opportunité pour les futures applications cliniques de la DOT. / In medical imaging, the ability to accurately retrieve and quantify the composition of turbid media is challenging and would enable to diagnose some diseases or to better study physiological processes. Diffuse optical tomography (DOT) is an attractive medical imaging technique which permits to probe in depth using near-infrared light and to reconstruct in three dimensions the composition of biological tissues non-invasively, non-ionizing and with potentially high specificity. To obtain endogenous chromophore (oxy- and desoxy-hemoglobin) features in the depth of a highly scattering medium, a multiwavelength time domain optical setup combined to a three-dimensional reconstruction algorithm was developed. Experimental measurements were conducted in reflectance geometry by illuminating a perturbed medium (with a heterogeneity) with a picosecond laser and by collecting, for several wavelengths and multi-positions, the backscattered light via two fibers connected to two dedicated detectors and coupled to a time-correlated single photon counting system. The data processing of these time-resolved measurements and those of a known reference medium was performed by supposing that the propagation of light is governed by the diffusion approximation and using a method based on Mellin-Laplace transform. Numerical and phantom experiments on series of objects similar to biological media demonstrate that this technique has the potential to give quantitative medical images. We have highlighted a correct quantification for the less absorbing objects at 10 mm depth while underestimation results at deeper depths and higher absorptions. Furthermore, the multimodal imaging brings improvements in quantification in depth and thus it can be a good opportunity to DOT for its future clinical applications.
20

Caractérisation de tissus biologiques par diffusion de la lumière : application au diagnostic du cancer / Biological tissues characterization by light scattering : cancer diagnosis application

Addoum, Ahmad 15 January 2018 (has links)
La Tomographie Optique Diffuse (TOD) est une nouvelle technique d'imagerie médicale permettant de reconstruire les propriétés optiques des tissus biologiques dans le but de détecter des tumeurs cancéreuses. Il s’agit, toutefois, d’un problème inverse mal-posé et sous-déterminé. Le travail de cette thèse s’articule autour de la résolution de ce problème en utilisant l’équation du transfert radiatif comme modèle de propagation de la lumière (modèle direct). L’analyse de sensibilité a montré que le facteur d’anisotropie g de la fonction de phase de Henyey-Greenstein est le paramètre le plus influant sur la sortie du modèle direct suivi du coefficient de diffusion µs puis du coefficient d’absorption µa. Dans un premier temps, un algorithme de Gauss-Newton a été implémenté en utilisant les fonctions de sensibilités. Toutefois, ce dernier ne permet d’estimer qu'un nombre très limité de paramètres optiques (supposés constants en espace). Dans un second temps, un algorithme de Quasi-Newton a été développé pour reconstruire les distributions spatiales des propriétés optiques. Le gradient de la fonction objectif a été calculé efficacement par la méthode adjointe à travers le formalisme de Lagrange avec une approche Multi-fréquences. Les reconstructions sont obtenues à partir des données simulées en surface. Le facteur g est reconstruit comme un nouvel agent de contraste en TOD. Le problème de diaphonie entre µs g a été donc mis en évidence dans cette thèse. Notre algorithme a permis de reconstruire en 2D et 3D une ou plusieurs inclusions tumorales présentant différentes formes. La qualité des images reconstruites a été examinée en fonction du nombre de fréquences, de la diaphonie, du niveau de contraste (Inclusion/Fond), du niveau de bruit et de la position des inclusions tumorales / Diffuse Optical Tomography (DOT) is a new medical imaging technique used to reconstruct the optical properties of biological tissues in order to detect cancerous tumors. However, this is an ill-posed and under-determined inverse problem. The work of this thesis deals with the resolution of this problem using the radiative transfer equation as a forward model of light propagation. The sensitivity analysis showed that the anisotropy factor g of the Henyey-Greenstein phase function is the most sensitive parameter of the forward model followed by the scattering coefficient µs and then the absorption coefficient µa. In a first step, a Gauss-Newton algorithm was implemented using the sensitivity functions. However, this algorithm allows to estimate a very limited number of the optical parameters (assumed to be constant in space). In a second step, a Quasi-Newton algorithm was developed to reconstruct the spatial distributions of the optical properties. The gradient of the objective function was efficiently computed by the adjoint method through the Lagrangian formalism with a Multi-frequency approach. The reconstructed images were obtained from simulated boundary data. The g factor was reconstructed as a new optical contrast agent in DOT and the crosstalk problem between this factor and µs has been studied. The results showed that the algorithm is efficient to reconstruct in 2D and 3D one or several tumor inclusions having different shapes. The quality of the reconstructed images was examined according to several parameters: the number of frequencies, the crosstalk, the contrast and the noise levels

Page generated in 0.0728 seconds