• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 13
  • 9
  • 2
  • Tagged with
  • 25
  • 25
  • 25
  • 13
  • 8
  • 7
  • 7
  • 7
  • 7
  • 6
  • 5
  • 5
  • 5
  • 5
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Histomorphometric and radiopharmaceutical investigations of the bone integration of implants in vivo laboratory models /

McCracken, Michael January 1999 (has links)
Thesis (Ph. D.)--University of Alabama at Birmingham, 1999. / eContent provider-neutral record in process. Description based on print version record. Includes bibliographical references.
12

Histomorphometric and radiopharmaceutical investigations of the bone integration of implants in vivo laboratory models /

McCracken, Michael January 1999 (has links)
Thesis (Ph. D.)--University of Alabama at Birmingham, 1999. / Includes bibliographical references.
13

Histomorphometric comparison of two collagen membranes for the treatment of implant dehiscence defects a thesis submitted in partial fulfillment ... for the degree of Master of Science in Periodontics ... /

Oh, Tae-Ju. January 2001 (has links)
Thesis (M.S.)--University of Michigan, 2001. / Includes bibliographical references.
14

Avaliações biomecânicas e biológicas relacionadas às próteses implanto-suportadas e aos implantes osseointegrados

Barão, Valentim Adelino Ricardo [UNESP] 31 August 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-08-31Bitstream added on 2014-06-13T20:25:51Z : No. of bitstreams: 1 barao_var_dr_araca.pdf: 1603640 bytes, checksum: 5d48588f784413a0d8cc560b1ff6d9b0 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Objetivos: (1) Investigar o papel de diferentes níveis de pH da saliva artificial (3; 6,5 e 9) no comportamento corrosivo do titânio comercialmente puro (cp-Ti) e da liga Ti-6Al-4V (Capítulo 1); (2) Avaliar a influência do processo de corrosão na afinidade do lipopolissacarídeo (LPS) de Escherichia coli para o cp-Ti e o Ti-6Al-4V (Capítulo 2); (3) Investigar a natureza tribocorrosiva do titânio em saliva artificial em presença de LPS (Capítulo 3); (4) Comparar o efeito de diferentes designs de overdentures implanto-retidas e prótese total fixa implanto-suportada na distribuição de tensões em mandíbula edêntula pelo método de elementos finitos tridimensional (Capítulo 4). Materiais e métodos: Testes eletroquímicos como potencial de circuito aberto, espectroscopia de impedância eletroquímica, e teste potenciodinâmico foram conduzidos. Para o teste de afinidade ao LPS, os espécimes foram tratados com LPS (1,5; 15 e 150 μg/ml) durante 24 horas para avaliar a aderência de LPS. Os discos foram transferidos a cada 24 horas para solução fresca de água livre de LPS até completar 72 horas, para investigar a liberação de LPS. No teste de tribocorrosão, o pH da saliva (6,5), a concentração de LPS (0, 0,15, 15 and 150 μg/ml), a duração do deslizamento (2000 ciclos), freqüência (1,2 Hz) e carga (20 N) foram usados para mimetizar o processo mastigatório. Finalmente, modelos tridimensionais de uma mandíbula edêntula foram construídos. No grupo OR a mandíbula foi restaurada com overdenture retida por implantes não esplitados com sistema de retenção O’ring; nos grupos BC-C e BC as mandíbulas foram restauradas com overdentures retidas por implantes esplintados com sistema de retenção barra-clipe associado ou não a cantilevers distais... / Objectives: (1) To investigate the role of different levels of pH of artificial saliva (pHs 3, 6.5 and 9) under simulated oral environment on the corrosion behavior of commercially-pure titanium (cp-Ti) and Ti-6Al-4V alloy (Chapter 1); (2) To assess the influence of corrosion process on Escherichia coli lipopolysaccharide (LPS) affinity for cp-Ti and Ti-6Al-4V alloy (Chapter 2); (3) To evaluate the tribocorrosive (corrosion/wear) nature of titanium in artificial saliva (pH 6.5) with LPS (Chapter 3); and (4) To compare the effect of different designs of implant-retained overdentures and fixed full-arch implant-supported prosthesis on stress distribution in edentulous mandible by using a three-dimensional finite element analysis. Materials and methods: Standard electrochemical tests, such as open circuit potential, electrochemical impedance spectroscopy, and potentiodynamic tests were conducted in a controlled environment. For LPS affinity test, specimens were treated with LPS (1.5, 15 and 150 μg/ml) for 24 hours to evaluated LPS adherence. Discs were then transferred every 24 hours to fresh LPS-free water, up to 72 hours, to investigate LPS elution. In the tribocorrosion test, the pH of saliva (6.5); LPS concentration (0, 0.15, 15 and 150 μg/ml), sliding duration (2000 cycles), frequency (1.2Hz) and load (20 N) parameters mimicked the mastication process. Finally, tridimensional models of an edentulous mandible were constructed. In the OR group, the mandible was restored with an overdenture retained by unsplinted implants with O’ring attachment; in the BC-C and BC groups, the mandibles were restored with overdentures retained by splinted implants with bar-clip anchor associated or not with distally placed cantilevers, respectively; in the FD group, the mandible was restored with a fixed full-arch implant-supported prosthesis... (Complete abstract click electronic access below)
15

Rehabilitation of fully edentulous maxilla = retrospective survival analysis of dental implants in native x autogenous bone and proposed technique for bone reconstruction with rhBMP-2 = Reabilitações de maxilas totalmente edêntulas: análise retrospectiva de sobrevida de implantes dentários em osso nativo x enxerto autógeno e proposta de técnica para reconstrução óssea com rhBMP-2 / Reabilitações de maxilas totalmente edêntulas : análise retrospectiva de sobrevida de implantes dentários em osso nativo x enxerto autógeno e proposta de técnica para reconstrução óssea com rhBMP-2

Moraes, Paulo Hemerson de, 1982- 24 August 2018 (has links)
Orientador: José Ricardo de Albergaria Barbosa / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-24T03:15:23Z (GMT). No. of bitstreams: 1 Moraes_PauloHemersonde_D.pdf: 8285563 bytes, checksum: e294a6dc0647058066633e61386f29b1 (MD5) Previous issue date: 2013 / Resumo: Em maxilas severamente absorvidas, como tratamento de reabilitação, podem ser utilizados os implantes dentais osseointegráveis convencionais. Todavia, nestas situações, estão presentes obstáculos para a instalação dos implantes como: quantidade insuficiente e qualidade inadequada do osso encontrado na maxila. Nestas situações, são necessárias cirurgias reconstrutivas para restabelecer as dimensões do rebordo avelolar em espessura e altura possibilitando assim a instalação adequada destes implantes. Geralmente, essas reconstruções utilizam osso autógeno retirado de algum sitio doador do paciente, como a calota craniana, costela e crista do ilíaco. Alternativamente, com os avanços da engenharia tecidual, a rhBMP-2 (recombinant human bone morphogenethic protein-2) surgiu eliminando a necessidade de qualquer remoção de sítio doador como também qualquer outro biomaterial nas reconstruções ósseas dos maxilares deixando o procedimento com menor morbidade e maior aceitabilidade dos pacientes. Desta forma, a presente pesquisa apresenta 2 estudos descritos nos capítulos a seguir. CAPÍTULO 1: O objetivo deste estudo foi avaliar a sobrevida de implantes instalados em osso nativo de maxilas como também nas reconstruídas com osso autógeno. Foi obtido um acompanhamento de 8-10 anos com pacientes de ambos os grupos reabilitados com próteses fixas sobre implantes dentais. O sucesso dos implantes em maxilas reconstruídas com ósso autogeno não apresentaram diferenças estatísticas à implantes inseridos em maxilas com osso nativo. CAPÍTULO 2: O objetivo deste estudo foi apresentar uma nova técnica de reconstrução óssea de maxila utilizando rhBMP-2 objetivando previsibilidade e melhores resultados no aumento do volume ósseo necessário. A técnica sugerida ofereceu bons resultados no volume ósseo a ser obtido nas reconstruções ósseas de maxila com rhBMP-2. / Abstract: In maxillary severely absorbed as rehabilitation treatment, can be used conventional dental implants. However, these situations are present obstacles to the installation of the implants as insufficient and inadequate quality of bone found in the jaw , as well as the expansion of the maxillary sinus pneumatization . In these situations, it is necessary reconstructive surgery to restore the dimensions of thickness and height on rim thus allowing proper installation of these implants. Generally, these reconstructions using autogenous bone taken from a donor site from the patient , such as calota craneal , rib and the iliac crest . Alternatively, with advances in tissue engineering, rhBMP-2 (recombinant human bone morphogenethic protein-2) appeared eliminating the need to remove any donor site as well as any other biomaterial in the maxila bone reconstruction procedure with leaving the lower morbidity and higher patient acceptability. Given the above, this research presents two studies described in the following chapters. CHAPTER 1: The objective of this study was to evaluate the survival of implants placed in native bone in the maxilla as well as in maxilla reconstructed with autogenous bone. We obtained a follow-up of 8-10 years with both groups of patients rehabilitated with fixed prostheses on dental implants. The survival of implants in maxilla was reconstructed with autogenous bone implants inserted into the lower maxilla with native bone. CHAPTER II: The objective of this study was to present a new technique for reconstruction of maxilla bone using rhBMP-2 seeking precision in increased bone volume needed. The suggested technique offered precision in bone volume to be obtained in the maxilla bone reconstruction with rhBMP-2. / Doutorado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Doutor em Clínica Odontológica
16

Photoelastic analysis of stress distribution around external hexagon and morse taper implants in different immediate loading systems = Análise fotoelástica da distribuição de tensões ao redor de implantes hexágono externo e cone Morse em diferentes sistemas de carga imediata / Análise fotoelástica da distribuição de tensões ao redor de implantes hexágono externo e cone Morse em diferentes sistemas de carga imediata

Odo, Caroline Hanada, 1987- 22 August 2018 (has links)
Orientador: Mauro Antônio de Arruda Nóbilo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-22T01:43:18Z (GMT). No. of bitstreams: 1 Odo_CarolineHanada_M.pdf: 1232143 bytes, checksum: 6ae3560319ddd48973319b39e8cbe764 (MD5) Previous issue date: 2013 / Resumo: Dentre diversos fatores que determinam o sucesso da osseointegração e da reabilitação protética, a biomecânica se destaca como fator fundamental. Utilizando a técnica da fotoelasticidade, o objetivo neste estudo foi avaliar as tensões geradas ao redor de implantes cone morse e hexágono externo osseointegrados após carregamento distal em diferentes técnicas de carga imediata: barra distal, fundição e solda a Laser. Três infraestruturas similares (uma para cada técnica) foram confeccionadas, sobre uma matriz metálica simulando um arco mandibular edêntulo. Cinco implantes foram dispostos de maneira a simular a distribuição clínica para protocolo inferior convencional. Análogos de mini pilares foram fixados na matriz metálica e após procedimento de transferência e obtenção de modelo em gesso especial, foram confeccionadas as infraestruturas protéticas. Estas foram utilizadas em novo procedimento de transferência e posteriormente, instaladas em modelo fotoelástico confeccionado com resina epóxi flexível (GIV, Polipox Indústria e Comércio Ltda - São Paulo - SP - Brasil). Foi realizado um carregamento pontual de 4,9N na região de primeiro molar inferior direito e, posteriormente primeiro molar inferior esquerdo. Foram avaliados cinco pontos pré-determinados ao longo do implante e as imagens foram analisadas no programa Fringes® de maneira qualitativa e quantitativa através da verificação das ordens de franjas ao redor dos implantes osseointegrados. A média dos valores foi submetida à análise de variância para dados com dois fatores de estudo, seguidos pelo teste de Tukey para comparação entre as médias. Os resultados não apresentaram diferença significativa entre as infraestruturas, porém apresentou diferença significativa entre os tipos de conexões. A partir dos resultados obtidos conclui-se que não há diferença na distribuição de tensão entre as técnicas de obtenção de infraestruturas, porém quando observados os tipos de conexão, o implante Cone Morse apresentou melhores resultados em relação à distribuição de tensão / Abstract: The objective of this study was to evaluate the stresses generated around morse taper and external hexagon osseointegrated implants after distal loading in different immediate loading techniques: distal bar, casting and laser welding. Three similar infrastructures (one for each technique) were fabricated on a metal matrix simulating an edentulous mandible arch. Five implants were arranged to simulate the clinical distribution of conventional lower protocol. Analogs of the implants were fixed in a metal matrix and a transfer procedure was made. After obtaining a special plaster model, the prosthetic infrastructures were fabricated. These were used on a new transfer procedure and subsequently installed in a photoelastic model made with flexible epoxy resin (GIV Polipox Industry and Commerce Ltd - São Paulo - SP - Brazil). A load application of 4.9N was performed at the region of lower right first molar and subsequently lower left first molar. Five predetermined points along the implant were evaluated and the images were analyzed in Fringes ® program in qualitative and quantitative way by checking the orders of the fringes around the dental implants. The mean values were statistically analyzed using a 2-Way analysis of variance and Tukey test. The results showed no significant difference between the infrastructure obtaining techniques, but significant difference was seen between the types of connection. From the results obtained it is concluded that the Morse taper implant showed better results in terms of stress distribution / Mestrado / Protese Dental / Mestra em Clínica Odontológica
17

The role of biomaterial properties in peri-implant neovascularization

Raines, Andrew Lawrence 08 July 2011 (has links)
An understanding of the interactions between orthopaedic and dental implant surfaces with the surrounding host tissue is critical in the design of next generation implants to improve osseointegration and clinical success rates. Critical to the process of osseointegration is the rapid establishment of a patent neovasculature in the peri-implant space to allow for the delivery of oxygen, nutrients, and progenitor cells. The central aim of this thesis is to understand how biomaterials regulate cellular and host tissue response to elicit a pro-angiogenic microenvironment at the implant/tissue interface. To address this question, the studies performed in this thesis aim to 1) determine whether biomaterial surface properties can modulate the production and secretion of pro-angiogenic growth factors by cells, 2) determine the role of integrin and VEGF-A signaling in the angiogenic response of cells to implant surface features, and 3) to determine whether neovascularization in response to an implanted biomaterial can be modulated in vivo. The results demonstrate that biomaterial surface microtopography and surface energy can increase the production of pro-angiogenic growth factors by osteoblasts and that these growth factors stimulate the differentiation of endothelial cells in a paracrine manner and the results suggest that signaling through specific integrin receptors affects the production of angiogenic growth factors by osteoblast-like cells. Further, using a novel in vivo model, the results demonstrate that a combination of a rough surface microtopography and high surface energy can improve bone-to-implant contact and neovascularization. The results of these studies also suggest that VEGF-A produced by osteoblast-like cells has both an autocrine and paracrine effect. VEGF-A silenced cells exhibited reduced production of both pro-angiogenic and osteogenic growth factors in response to surface microtopgraphy and surface energy, and conditioned media from VEGF-A silenced osteoblast-like cell cultures failed to stimulate endothelial cell differentiation in an in vitro model. Finally, the results show that by combining angiogenic and osteogenic biomaterials, new bone formation and neovascularization can be enhanced. Taken together, this research helps to provide a better understanding of the role of material properties in cell and host tissue response and will aid in the improvement of the design of new implants.
18

Influência de implantes pós-exodônticos com diferentes configurações sobre os tecidos peri-implantares: estudo experimental em cães

Caneva, Marco [UNESP] 05 September 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:40Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-09-05Bitstream added on 2014-06-13T21:04:26Z : No. of bitstreams: 1 caneva_m_dr_araca.pdf: 5420643 bytes, checksum: 2a88c9a9a85203bfd0cd8f4fd62affa4 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Objetivo: avaliar a influência da instalação de implantes em alvéolos imediatamente após a extração do elemento dental na regeneração dos tecidos peri-implantares com implantes de diferentes configurações Material e métodos: Nos alvéolos distais dos quartos pré-molares mandibulares de cães, imediatamente após as extrações das raízes dentais, foram instalados implantes cilíndricos com 3,3 mm de diâmetro (grupo controle) e implantes cônicos com 5,0 mm de diâmetro (grupo teste). Foram avaliados histologicamente a regeneração dos tecidos duros e moles peri-implantares após 4 meses do procedimento cirúrgico. Resultados: Todos os implantes apresentaram-se osseointegrados ao tecido ósseo maduro mineralizado. A crista óssea alveolar sofreu reabsorção tanto no grupo teste como controle. A superfície óssea vestibular dos implantes do grupo teste (cônico; 3,6 mm) apresentou maior grau de reabsorção em comparação ao grupo controle (cilíndrico; 1,6 mm). As dimensões dos tecidos moles apresentaram-se semelhantes em ambos os grupos. No entanto, em relação ao ombro do implante, a mucosa peri-implantar localizou-se mais apicalmente no grupo teste em relação ao grupo controle. Conclusão: Este estudo confirmou que a distância entre a superfície do implante e o contorno externo da crista óssea alveolar vestibular influenciou no grau de reabsorção da tábua óssea vestibular. Conseqüentemente, em relação ao ombro do implante, a mucosa peri-implantar será estabelecida em um nível mais apical, se a distância entre a superfície do implante e o contorno externo da crista óssea alveolar for menor / Aim: the aim of the present experiment was to study the influence of implant installation into sockets immediately after tooth extraction on the healing periimplant tissues with implants of various configurations. Material & methods: Transmucosal cylindrical 3.3mm in diameter implants in the control sites, and conical 5.0mm in diameter in the test sites, were installed into the distal socket of the forth mandibular premolars in dogs immediately after tooth extraction. After 4 months, the hard and soft tissue healing was evaluated histologically. Results: All implants were integrated in mineralized mature bone. Both at the test and control sites, the alveolar crest underwent resorption. The buccal bony surface at the implant of the test sites (conical; 3.6mm) was more resorbed compared to the control sites (cylindrical; 1.6mm). The soft tissue dimensions were similar in both groups. However, in relation to the implant shoulder, the periimplant mucosa was located more apically at the test compared to the control sites. Conclusion:The present study confirmed that the distance between the implant surface and the outer contour of the buccal alveolar bony crest influenced the degree of resorption of the buccal bone plate. Consequently, in relation to the implant shoulder, the peri-implant mucosa will be established at a more apical level if the distance between the implant surface and the outer contour of the alveolar crest is small
19

Avaliação da incorporação de enxertos ósseos homógenos em humanos: análises histológica e imunoistoquímica

Abla, Marcelo Sabbag [UNESP] 27 February 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:40Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-02-27Bitstream added on 2014-06-13T19:22:10Z : No. of bitstreams: 1 abla_ms_dr_araca.pdf: 493211 bytes, checksum: 7b996be2b8e49d11e130d4903e67a50b (MD5) / O osso homógeno fresco congelado tem sido utilizado no intuito de substituir o osso autógeno. No entanto as suas propriedades de osteoindução e até mesmo osteocondução não estão bem conceituadas na literatura científica. Esse trabalho teve por objetivo avaliar amostras de tecido ósseo homógeno enxertados em humanos através das análises qualitativas histológica e imunoistoquímica. Para tal, dez pacientes previamente selecionados foram submetidos à cirurgia de reconstrução de defeitos ósseos em espessura, usando enxerto ósseo homógeno em bloco fresco congelado estabilizado e fixado por meio de parafusos bicorticais. Após período de integração de seia meses foi realizado procedimento de reabertura para instalação dos implantes osseointegráveis. Neste momento cirúrgico, amostras do enxerto ósseo foram removidas por meio de broca trefina. As amostras foram fixadas em formol 10%, levadas ao processamento para corte descalcificado em parafina e coradas por hematoxilina e eosina. Realizou-se processamento imunoistoquímico para a expressão da enzima Caspase 3. As lâminas foram levadas à microscopia óptica para realização das análises histológica e imunoistoquímica qualitativas. Os resultados mostraram tecido ósseo não vital, com poucas áreas de deposição de osso neoformado sobre a matriz amorfa, presença de infiltrado inflamatório com áreas de osteomielite e imunomarcação expressiva da enzima Caspase 3. Diante da metodologia empregada e dos resultados obtidos concluiu-se que o enxerto homógeno apresentou somente a propriedade biológica de osteocondução durante a fase de incorporação de seis meses / Allogeneic bone has been used fresh frozen in order to replace bone autograft. However, the properties of osteoinduction and osteoconduction are not even well-regarded in the scientific literature. This work aimed to evaluate samples of homogenous bone grafts in humans by qualitative histological analysis and immunohistochemistry. For this ten pre-selected patients underwent surgical reconstruction of bone defects in thick, homogenous bone graft using fresh frozen block stabilized and fixed by bicortical screws. After integration period of six months reopening procedure was performed for installation of osseointegrated implants. At this surgical time bone graft samples were removed by means of drill trephine. The samples were fixed in formalin 10%, taken to court for processing decalcified paraffin, and stained with hematoxylin and eosin. Immunohistochemistry was performed processing for the expression of the enzyme Caspase 3. The slides were brought to light microscopy to carry out the qualitative histology and immunohistochemistry. The results showed non-vital bone tissue, with few areas of deposition of new bone formation on the amorphous matrix, presence of chronic inflammatory infiltrate with areas of osteomyelitis, and immunostaining expressive of the enzyme Caspase 3. Given the methods employed and the results obtained it was concluded that the graft showed only a homogenous biological property of osteoconduction, during the incorporation of six months
20

Fresamento corretivo de estruturas implanto-retidas : influencia na adaptação marginal e na confiabilidade do teste do parafuso unico / Multi-unit implant-supported frameworks corrective finishing : influence on the marginal misfit and reliability of single-screw test

Daroz, Luiz Gustavo Dias 24 February 2006 (has links)
Orientador: Guilherme Elias Pessanha Henriques / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-06T09:25:51Z (GMT). No. of bitstreams: 1 Daroz_LuizGustavoDias_M.pdf: 1050394 bytes, checksum: 25c85e7dd89cc812e9e871cdc982a3a1 (MD5) Previous issue date: 2006 / Resumo: A obtenção de uma peça perfeitamente adaptada aos componentes de retenção, mantendo a resistência estrutural a custo acessível é o principal objetivo durante a construção de uma prótese implanto-retida de múltiplos elementos. Além disto, julgar a qualidade da adaptação das peças depende da confiabilidade dos métodos existentes para determinação da passividade. O objetivo deste estudo foi determinar o desajuste marginal de infra-estruturas metálicas implanto-retidas tipo monobloco antes e após o fresamento corretivo destas peças empregando retificador manual. Avaliou-se ainda a hipótese de que os procedimentos de fresamento corretivo podem ter influência sobre a confiabilidade do teste do parafuso único utilizado para averiguação de adaptação marginal de peças múltiplas sobre implantes. Foram confeccionadas 40 infra-estruturas metálicas pela técnica do monobloco, sendo 20 fundidas em titânio comercialmente puro (Ti c.p.) e outras 20 fundidas em liga de cobalto-cromo (Cr-Cr). Para tal, utilizou-se matriz metálica simulando a disposição clínica de implantes osseointegrados na região interforames mentonianos contendo 5 análogos de pilares cônicos para peças múltiplas padrão Branemark (Micro-Unit - Conexão) e cilindros protéticos calcináveis compatíveis. As peças confeccionadas em Ti c.p. e em Co-Cr, foram subdivididas em 2 subgrupos (n=10) de acordo com a seqüência de retificação a que foram impostas: Seqüência A ¿ fresamento corretivo das bordas de adaptação dos cilindros protéticos seguido do fresamento corretivo da base de assentamento da cabeça do parafuso protético ao pilar; e, Seqüência B ¿ fresamento corretivo da base de assentamento da cabeça do parafuso protético ao pilar seguido do fresamento corretivo das bordas de adaptação dos cilindros protéticos. A conduta forneceu um total de 4 grupos experimentais (Titânio A e B; Co-Cr A e B). As leituras de desajuste marginal, realizadas sobre a matriz metálica e com auxílio de um microscópio mensurador, foram baseadas na técnica do parafuso único e realizadas em cada estrutura antes e após cada etapa de retificação corretiva. As médias de desajuste marginal de cada estrutura foram calculadas e consideradas como uma unidade para a análise estatística. O teste de Friedman foi aplicado com nível de significância de 5% para avaliar o efeito dos diferentes passos de retificação sobre o desajuste marginal. Nos Grupos Ti A e B, assim como no Grupo Co-Cr A, não foi observada diferença significativa entre as condições experimentais (Grupo Ti A, p=0,9048; Grupo Ti B, p=0,273 e Grupo Co-Cr A, p=0,4966). Porém, diferenças estatisticamente significativas foram observadas no Grupo Co-Cr B, após a retificação corretiva das bordas dos cilindros fundidos (p=0,0017). Foi concluído que os procedimentos de fresamento corretivo não mostraram efeito significativo sobre a adaptação marginal das pecas de titânio. Contudo, em um grupo de peças fundidas em Co-Cr, a retificação das bordas dos cilindros mostrou efeito adverso sobre a passividade. Os procedimentos de fresamento corretivo parecem não apresentar influência significativa sobre a confiabilidade do teste do parafuso único, porém, devem ser realizados cuidadosamente, necessitando de aperfeiçoamentos para uma utilização segura / Abstract: The fabrication of a passively fitting framework over abutments and fixtures, maintaining its structural integrity and with a low costs, is the ultimate goal of the construction process of a multi-unit implant-support prosthesis. Furthermore, the accuracy and reliability of the passive fit determination methods have a crucial hole on framework misfit analysis. The objective was to evaluate the passive fit by the single-screw test method of cast commercially pure titanium (CP Ti) implantsupported frameworks after the corrective finishing of cast cylinders fitting borders and screw seats. The hypothesis tested was that finishing procedures could affect the single screw test measurements reliability. Were fabricated 40 frameworks by onepiece casting method, being 20 CP Ti frameworks and others 20 Co-Cr frameworks. A metallic index containing 05 Branemark-type multi-unit abutment analogs and respective calcinable cylinders were used to frameworks fabrication. The CP Ti and Co-Cr frames were assembled in 2 sub-groups (n=10) accordingly with the finishing sequence proposed: Group A - corrective finishing of cast cylinder borders followed by corrective finishing of cast cylinder screw seats - and Group B - corrective finishing of cast cylinder screw seats followed by corrective finishing of cast cylinder borders-. This conduct produce 4 experimental groups (CPTi A and B; Co-Cr A and B). The marginal gaps, assessed over the metallic matrix using a traveling microscope, were carried out before and after each corrective finishing step accordingly with one screw test protocol. The marginal misfit means of each framework was considered as a unit to statistical analyses. The Friedman¿s test was used with significance level set as 5% to analyze the effect of the different corrective finishing steps over frameworks passive fit. In the CPTi A and B Groups, and in the Co-Cr A Group, there was no significant differences between experimental conditions (Group CPTi A, p=0.9048; Group CPTi B, p=0.273 and Grupo Co-Cr A, p=0.4966). However, in the CPTi B Group, a significant difference was found after cast cylinder fitting borders corrective finishing (p=0.0015). It was concluded that the finishing process does not show any effect over Ti framewoks misfit values. However, to a group of Co-Cr frames, the fitting borders corrective finishing has a deleterious effect over passivity. The corrective finishing procedures seamed do not influence the single-screw test reliability, nevertheless, it should be used carefully and requires further improvements to guarantee a sever usage / Mestrado / Protese Dental / Mestre em Clínica Odontológica

Page generated in 0.1144 seconds