• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 174
  • 56
  • 11
  • 7
  • 7
  • 7
  • 7
  • 7
  • 5
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 281
  • 140
  • 134
  • 127
  • 97
  • 85
  • 76
  • 70
  • 41
  • 39
  • 35
  • 31
  • 29
  • 28
  • 26
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
221

Ticp e liga Ti-13Nb-13Zr com diferentes tratamentos de superfície-testes in vitro e in vivo / Ticp and Ti-13Nb-13Zr alloy with different surface treatments - in vitro and in vivo tests

AGREDA, CAROLA G. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:41:19Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:03Z (GMT). No. of bitstreams: 0 / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
222

Avaliação clínica e radiográfica dos tecidos peri-implantares de implantes osseointegrados que receberam carregamento imediato /

Lemo, Vagner Samy. January 2004 (has links)
Resumo: Um estudo clínico e radiográfico foi realizado para analisar o resultado do tratamento com implantes unitários e unidos (prótese protocolo), instalados e imediatamente carregados. O estudo inclui 10 pacientes que receberam 10 implantes e próteses provisórias unitárias e 5 pacientes que receberam 25 implantes, 5 implantes cada paciente entre os foramens mentoniano, estes foram unidos e receberam uma prótese tipo protocolo. Todas as próteses foram instaladas imediatamente após a cirurgia. Em um intervalo de 6 e 12 meses todos os pacientes foram radiografados e avaliados clinicamente. Não foram registradas perdas no grupo de implantes unitários e o grupo de implantes que recebeu prótese protocolo perdeu 2 implantes. Não houve alterações nos parâmetros periodontais (clínicos e radiográficos) entre os períodos de 6 e 12 meses, e as diferenças encontradas entre os implantes unitários e unidos, parecem estar mais relacionados ao local de inserção (maxila - mandíbula). Podemos concluir que a carga imediata é um procedimento previsível tanto para implantes unitários como em implantes unidos. / Abstract: The study includes 10 patient that received 10 implants and unitary temporary prostheses and 5 patient that received 25 implants, 5 implants each patient one in the area previous of jawbone, these were united and they received a prosthesis type protocol. All of the prostheses were installed immediately after the surgery. In an interval of 6 and 12 months all the patients were x-rayed and evaluated clinically. Losses were not registered in the group of unitary implants and the group of implants that it received prosthesis protocol lost 2 implants. There were not alterations in the periodontal parameters (clinical and radiographic) among the periods of 6 and 12 months, and the differences found among the unitary and united implants, they seem to be more related to the insert place (jawbone - jaw). We can conclude that the immediate load is a previsible procedure so much for unitary implants as in united implants. / Orientador: Elcio Marcantonio / Coorientador: Elcio Marcantonio Junior / Banca: Roberto Henrique Barbeiro / Banca: Wilson Trevisan Junior / Mestre
223

Osseointegração de implantes de titânio com modificação da superfície por ablação a laser e recobrimento por hidroxiapatita biomimética : estudo biomecânico e histomorfométrico em tíbia de coelhos /

Faeda, Rafael Silveira. January 2010 (has links)
Orientador: Elcio Marcantonio Junior / Banca: Celso Eduardo Sakakura / Banca: Ana Emília Farias Pontes / Banca: Andréa Cândido dos Reis / Banca: Maria Lúcia Rubo de Rezende / Resumo: O sucesso dos sistemas modernos de implantes dentais tem sido relacionado ao desenvolvimento do design e das características de superfícies dos implantes. O propósito do presente estudo foi avaliar duas novas superfícies de implantes (modificada por laser - LMS e recoberta por hidroxiapatita biomimética - HA), comparando-as a outro implante comercial, (superfície usinada - MS). Um total de 144 implantes (3,75 x 10mm), 48 de cada superfície, foram instalados na tíbia de coelhos e avaliados após 4, 8 e 12 semanas. Após os períodos de cicatrização os animais foram sacrificados, um dos implantes expostos e a força necessária para derosquea-los foi aferida por um torquímetro analógico. O outro implante foi removido com o tecido ósseo peri-implantar e processado por corte histológico calcificado para análise histomorfométrica do contato osso-implante (BIC%) e da área óssea entre espiras (BBT%). Em 4 e 8 semanas, os implantes HA apresentaram valor de torque de remoção estatisticamente superior (p<0,05) quando comparado aos demais, sendo o mesmo observado para os implantes LMS quando comparados aos MS. Após 12 semanas, os implantes HA e LMS foram estatisticamente superiores aos implantes MS. Por outro lado, a análise do contato osso-implante mostrou que na região cortical, os implantes LMS e HA foram estatisticamente superiores ao MS para todos os períodos de cicatrização, sem diferença estatística entre LMS e HA. A análise histomorfométrica mostrou que, quando comparados na região endosteal, os implantes LMS e HA foram estatisticamente superiores ao MS no período inicial de cicatrização. Embora os implantes LMS e HA não apresentassem diferenças estatísticas entre eles, uma tendência de maiores valores de BIC% para HA na região endosteal foi observada em todos os períodos do estudo.Os resultados deste estudo mostram que apesar de não haver diferença... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Purpose: Considering the great biological potential of the association between laser ablation and hydroxyapatite thin layer coatings to create an interesting bioactive environment on titanium dental implants, the aim of the present study was to investigate, by histomorphometrical and removal torque analysis, the histological effects of a surface treatment created by laser-ablation (Nd:YAG) and, later, thin deposition of HA particles by a chemical process compared to implants with only laser-ablation and implants with machined surfaces. Materials and Methods: Forty-eight rabbits received two implant by tibiae of the following surfaces: Machined surface (MS), laser-modified surface (LMS) and biomimetic hydroxiapatite coated surface (HA). After 4, 8 and 12 weeks of healing, one implant was exposed, and the needed force to unscrew measured using an analogical torque gauge. The other implant and surrounding bone was removed and prepared by a calcified histological process. The percentage of bone-to-implant contact (BIC) and the bone area formed between the threads (BBT) were evaluated separately to the cortical and endosteal region. Results: The difference was statistically significant (P < .05) between the LMSMS and HA-MS surfaces in all periods of evaluation, and between LMS-HA to 4 and 8 weeks of healing. The surface characterization showed a deep, rough, and regular topography provided by the laser conditioning, that was followed by the HA coating. Average BIC percentage in the cortical region was significantly higher (P<0.001) on the LMS and HA implants, compared with MS ones for all periods of healing, having no statistical differences between LMS and HA. When compared in the endosteal area, the LMS and HA implants showed statistically higher (P<0.01) BIC percentage values than MS at the initial periods of healing (LMS after 4 weeks and HA after 4 and 8 weeks, respectively)... (Complete abstract click electronic access below) / Doutor
224

Avaliação do plasma de argônio na integração dos tecidos moles e duros aos implantes e componentes protéticos: estudo randomizado em cães / Evaluation of argon plasma in the integration of soft and hard tissues to implants and prosthetic components: a randomized study in dogs

Evandro Carneiro Martins Neto 07 December 2017 (has links)
Diversas aplicações do plasma de argônio tem sido encontradas na literatura. Na odontologia, suas aplicações se referem a capacidade de limpeza de componentes e aumento da energia de superfície. Os tratamentos para melhorar a energia de superfície são estudados com objetivo de criar um ambiente mais favorável para a adesão celular. Este estudo teve como objetivo avaliar histologicamente as mudanças nos tecidos moles e duros após a inserção de implantes e pilares de titânio limpos e ativados com plasma de argônio. Foram instalados 64 implantes e pilares em 8 cães Beagle, sendo randomizados em dois grupos: tratados com plasma de argônio ou não tratados. Dois tempos experimentais foram realizados: 4 e 8 semanas. Após esse período, os animais foram sacrificados, as mandíbulas foram divididas em blocos individuais e processados para confecção de lâminas para análise histológica. Na análise dos pilares, não houve diferença estatística entre os grupos, apesar de maiores níveis de osso marginal nos locais de teste em comparação com os locais de controle. Em relação aos implantes de titânio, as diferenças entre teste e controle, principalmente no período de 8 semanas, podem sugerir que o uso de plasma de argônio poderia melhorar a integração dos tecidos periimplantares à superficie dos implantes. / Several applications of argon plasma have been found in the literature. In dentistry, its applications refer to the ability to clean components and increase surface energy. Treatments for enhancing surface energy were studied in an effort to create a more favorable environment for cell adhesion. This study aimed to histologically evaluate changes in soft and hard tissues after insertion of implants and titanium abutments cleaned and activated with argon plasma. 64 implants and abutments were installed in 8 Beagle dogs, and were randomized into two groups: treated with argon plasma or untreated. Two experimental times were performed: 4 and 8 weeks. After this period, the animals were sacrificed, the jaws were divided into individual blocks and processed for histological analysis. In the analysis of abutments, there was no statistical difference between groups, despite higher levels of marginal bone in test sites compared to the control sites. Regarding titanium implants, the differences between test and control, especially in the 8-week period, may suggest that the use of argon plasma could improve the integration of peri-implant tissues to the implant surface.
225

Implantes porosos à base de titânio, avaliação in vitro e in vivo / Titanium based porous implants, in vitro and in vivo evaluation

GOIA, TAMIYE S. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:35:57Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:59:48Z (GMT). No. of bitstreams: 0 / O desenvolvimento de biomateriais com estrutura porosa visa permitir uma boa ancoragem biológica através do crescimento do tecido ósseo no interior dos poros, além de no caso de algumas ligas de titânio, proporcionar valores de módulo elástico semelhantes ao do osso, prevenindo assim o insucesso por reabsorção óssea na interface com o implante. O objetivo deste estudo foi avaliar o processamento de implantes porosos à base de titânio produzidos por metalurgia do pó, utilizando polímeros naturais como aditivos (albumina, amidos de arroz, batata, milho e a gelatina), e analisar a osteointegração desses implantes por ensaio in vivo. Foram obtidas, amostras de titânio comercialmente puro (Ticp) e da Liga Ti-13Nb-13Zr pelos processos de space-holder e suspensão; os polímeros naturais foram removidos termicamente (350°C/1h) previamente a sinterização (1300°C/1h e 1300°C/3h, respectivamente). As metodologias de processamento utilizando aditivos de baixo custo propiciaram a obtenção de implantes metálicos porosos de maneira simplificada, com porosidades diferenciadas, boa homogeneidade estrutural, grau de porosidade adequado (entre 40% e 60%), distribuição e tamanho dos poros conforme o polímero natural formador. Na caracterização biológica, o teste in vitro de citotoxicidade validou a utilização dos implantes para a realização do teste in vivo. A avaliação da osteointegração foi realizada em coelhos da raça New Zealand em períodos de 49 dias. Na análise histológica por microscopia eletrônica de varredura e fluorescência, foram obtidos os resultados quantitativos e qualitativos da osteointegração, com crescimento ósseo em todos os implantes, apresentando osteocondutividade. Os melhores resultados ocorreram em implantes com porosidade homogênea, e com tamanho médio de poros entre 100 e 200 &mu;m. Assim, os materiais porosos de titânio e da liga Ti-13Nb-13Zr produzidos com os polímeros naturais (amido de arroz, amido de batata, amido de milho, gelatina e albumina), permitiram a nutrição e manutenção necessárias para a sobrevivência das células, comprovando a osteointegração e osteocondução dos implantes desenvolvidos. / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
226

Ticp e liga Ti-13Nb-13Zr com diferentes tratamentos de superfície-testes in vitro e in vivo / Ticp and Ti-13Nb-13Zr alloy with different surface treatments - in vitro and in vivo tests

AGREDA, CAROLA G. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:41:19Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:03Z (GMT). No. of bitstreams: 0 / O titânio e suas ligas são biomateriais metálicos extensamente utilizados em aplicações médicas e odontológicas, apesar de não formarem ligação química com o osso circundante. Por isto é desejável técnicas que proporcionem a bioatividade na superfície desses metais. A proposta deste estudo foi avaliar e comparar, por testes in vitro e in vivo o comportamento de Ticp e da liga Ti-13Nb-13Zr utilizando diferentes tratamentos de superfície frente à formação do recobrimento biomimético e ao processo de osteointegração. Foram utilizadas placas comerciais de Ti e amostras da liga e de Ticp, obtidas por M/P. As amostras foram submetidas a quatro diferentes tratamentos de superfície (padrão - tratamento alcalino; 1°- tratamento alcalino e térmico; 2°- tratamento ácido e alcalino; 3º- tratamento alcalino, CaCl2, térmico e água quente), analisadas quanto à formação de apatita em SBF em períodos de 1 a 21 dias. Os recobrimentos obtidos foram caracterizado por MEV e DRIFT. Para a avaliação in vivo dos implantes, obtidos por M/P, de Ticp e da liga, com e sem tratamentos superficiais, foram utilizados coelhos adultos machos. A avaliação teve duração de 7 semanas em que foram aplicados marcadores celulares ósseos em tempos e sequência específicos do pós-operatório. Na avaliação in vitro, os recobrimentos de maior espessura foram nas amostras obtidas por M/P, comparativamente à amostra laminada. Todos os tratamentos foram efetivos na promoção da bioatividade. O 2º tratamento obteve recobrimento com maior espessura nos períodos avaliados para todas as superfícies. Na avaliação in vivo, ocorreu crescimento ósseo com osteointegração em todos os implantes com e sem tratamentos superficiais. O crescimento ósseo na interface osso/implante ocorreu de forma contínua em todo o período de reparação para o Ticp, o Ticp com tratamento padrão, o Ticp com o 2º tratamento e a liga com o 1° tratamento; e ocorreu de forma mais intensa no primeiro e terceiro período de reparação para os demais implantes. Os resultados dos testes in vitro e in vivo não são passíveis de analogia direta neste estudo, pois forneceram informações importantes sobre a formação, morfologia e taxa de aposição do recobrimento aos diferentes tratamentos de superfície e a efetividade da osteointegração destes tratamentos de superfície em modelo animal. / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
227

Comparação entre implantes unitários de superfície tratada e não tratada por sub-tração radiográfica digital em protocolos de carga imediata e convencional / Comparison between single-tooth treated and non treated surface implants by digital subtraction radiography on immediate and con-ventional loading protocols

CARNEIRO, Luciano Sandoval 27 March 2009 (has links)
Made available in DSpace on 2014-07-29T15:21:59Z (GMT). No. of bitstreams: 1 Dissertacao - Luciano Sandoval Carneiro.pdf: 579690 bytes, checksum: 7c2af9622df94b48e0c190f4b97fbcff (MD5) Previous issue date: 2009-03-27 / Objectives: To compare by digital subtraction radiography (SR), matched to clinical evaluation, bone response to single-tooth treated (TS) and non-treated (NTS) surface implants on immediate (IM) and conventional (CO) loading protocols. Material and methods: 12 patients (8 underwent IM protocol and 4 underwent CO protocol) received 24 implants. Each subject received 2 implants (one with TS and the other NTS) homologously and bilaterally positioned in maxillae (lateral incisor, canine or premolar regions) or mandible (molar area). Standardized radiographies of each implant were taken on the day after implant placement (baseline image) and after 3, 6 and 12 months (follow-up images). SR was used for crestal bone loss (CBL) and peri-implant bone density (PIBD) measurements. The placement torque and resonance frequency (at 0, 6 and 12 months) were also measured for matching radiographic data. Results: T-test revealed no statistically significant difference in CBL between TS and NTS implants, while TS implants presented higher PIBD in the mid-implant region at 3-months recall (p = 0.04). For IM protocol, the Mann-Whitney test revealed higher CBL at 6-months follow-up (p = 0.03), greater PIBD at 12-months recall (p = 0.06; p = 0.07) and increasing PIBD through time. There was a positive correlation between primary stability and PIBD at 12-months recall (r = 0.58; p = 0.005). Conclusions: TS and NTS implants presented similar performances with regard to CBL and PIBD. IM and CO protocols were similarly successful. Primary stability was an important element in reaching greater PIBD after 1-year loading period / Objetivos: O objetivo desse estudo foi comparar através da subtração radiográfica digital (SRD), associada à avaliação clínica, a resposta óssea a implante unitário de superfície tratada (ST) e a implante de superfície não tratada (SNT) utilizando protocolos de carga imediata (CI) e convencional (CON). Material e métodos: 12 pacientes (8 pelo protocolo de CI e 4 pelo protocolo de CON) receberam um total de 24 implantes. Cada indivíduo recebeu dois implantes, um de ST e outro de SNT, em posições homólogas bilaterais na maxila (regiões de incisivos laterais, caninos ou pré-molares) ou na mandíbula (área de molares). Imagens radiográficas padronizadas de cada implante foram obtidas no dia seguinte após procedimento cirúrgico de instalação (imagem de referência) e em 3, 6 e 12 meses seguintes (imagens de controle). As imagens foram submetidas à SRD para avaliação da perda de crista óssea alveolar (PCO) e obtenção da densidade óssea peri-implantar (DOPI). Além das radiografias padronizadas, o torque de inserção e a freqüência de ressonância dos implantes (em 0, 6 e 12 meses) foram medidos com finalidade de correlacioná-los à avaliação radiográfica. Resultados: O teste T revelou ausência de diferença estatisticamente significativa entre implantes de ST e SNT em relação a PCO, enquanto o grupo de ST apresentou maior DOPI apenas na região de terço médio no controle de 3 meses (p = 0,04). Para o grupo submetido ao protocolo de CI, o teste de Mann-Whitney demonstrou maior PCO no controle de 6 meses (p = 0,03), maior DOPI no controle de 12 meses (p = 0,06; p = 0,07) e DOPI crescente ao longo do tempo. Houve uma correlação positiva entre a estabilidade primária e a DOPI no controle de 12 meses (r = 0,58; p = 0,005). Conclusões: Os implantes de ST e SNT apresentaram comportamentos semelhantes quanto a PCO e DOPI. O protocolo de CI exibiu sucesso comparável ao do protocolo de CON. A estabilidade primária dos implantes foi um fator importante para atingir maior DOPI após 1 ano sob a ação de carga
228

Uso do cimento de osso alfa-tricálcio-fosfato no tratamento cirúrgico da cavidade mastóidea. Estudo experimental / Alpha-tricalcium phosphate bone cement in the surgical treatment of mastoid cavity. Experimental study

Robinson Koji Tsuji 08 September 2008 (has links)
Introdução: A mastoidectomia cavidade aberta é considerada por muitos autores o procedimento cirúrgico de escolha para o tratamento da otite média colesteatomatosa, devido à alta incidência de recidiva da doença. Porém, a formação desta cavidade única pode gerar algumas complicações e a obliteração da cavidade mastóidea é uma técnica descrita e estudada para a eliminação desta cavidade. Materiais aloplásticos têm sido estudados em cirurgias de obliteração da cavidade mastóidea, porém estes materiais podem apresentar problemas de biocompatibilidade e de rejeição O cimento de osso alfa -tricálcio-fosfato é um material composto por cálcio e fosfato e apresenta composição bioquímica semelhante à fase mineral do osso. Embora já utilizado em cirurgias há mais de 10 anos, não existem estudos sobre a sua aplicação nas cirurgias de obliteração de cavidade mastóidea na literatura. Objetivo: Estudar a biocompatibilidade do cimento de osso alfatricálcio- fosfato na obliteração da cavidade mastóidea em guinea pigs. Casuística e Métodos: Vinte Cavia porcellus (guinea pig) fêmeas foram submetidos a procedimento cirúrgico na bula timpânica esquerda. Em 10 cobaias (grupo cimento) a bula timpânica foi obliterada com o cimento de osso alfa-tricálcio-fosfato e em 10 cobaias (grupo controle) a cavidade foi deixada sem preenchimento. 60 dias após o procedimento os animais foram sacrificados e avaliados quanto à presença de sinais clínicos de rejeição ao material e outras complicações. Os ossos temporais foram removidos e submetidos à análise histopatológica. Foram avaliados o tipo e o grau de resposta inflamatória e o grau de ossificação. Resultados: A taxa de mortalidade foi igual em ambos os grupos. As mortes foram atribuídas a complicações anestésicas. Entre as cobaias que completaram o estudo não foram observados sinais de complicações em nenhum caso. Oito animais (100%) do grupo cimento em e cinco animais (62,5%) apresentaram resposta inflamatório graus I e II que correspondem histopatologicamente a alterações cicatriciais normais ao procedimento cirúrgico. Não foi observado presença de reação inflamatória crônica tipo corpo estranho em nenhuma amostra de ambos os grupos. Quanto ao grau de ossificação, a média dos escores de ossificação no grupo controle (3,5) foi maior que o observado no grupo cimento (1,0). O grupo controle (3,5 ± 5) apresentou grau de ossificação estatisticamente maior quando comparado com o grupo cimento (1,0 ± 0,0) (p < 0,01). Conclusões: 1) O cimento de osso alfa-tricálciofosfato é biocompatível em osso temporal de cobaia. 2) O cimento de osso alfa-tricálcio-fosfato sofre remodelação óssea, porém não apresenta propriedade de osteocondução / Introduction: Many authors consider open cavity mastoidectomy the surgical procedure of choice for the treatment of otitis media with cholesteatoma, due to the high incidence of recurrence of the disease. However, the formation of this open cavity can generate some complications and mastoid cavity obliteration is one type of technique for the elimination of this cavity. Alloplastic materials have been testes in mastoid cavity obliteration, however such materials can present problems of biocompatibility and rejection. Alphatricalcium phosphate bone cement is a material compose of calcium and phosphate and presents physicochemical characteristics similar to the bone mineral fase. Although it has been used for more than 10 years, there are no studies in the literature on its application in mastoid cavity obliteration. Objective: This study aimed to evaluate the biocompatibility of alphatricalcium phosphate bone cement in the obliteration of the mastoid cavity in guinea pigs. Methods: We studied 20 Cavia porcellus (guinea pig) submitted to surgical manipulation of the left dorsal tympanic bulla. In the study group animals (n = 10), mastoid cavity obliteration was conducted with alphatricalcium phosphate bone cement. In the control group animals (n = 10), the cavity was left unfilled. On postoperative day 60, the animals were sacrificed and studied for signs of rejection of the material and other complications. Temporal bones were removed for histopathological study, in which the type and degree of inflammatory response, as well as the degree of ossification, were analyzed. Results: The mortality rate was the same in both groups. Deaths were attributed to anesthetic complications in the initial postoperative period. In the animals that survived, there were no complications. The histological analysis of the degree and type of inflammatory response shown no signs of foreign body in both groups, 8 (100%) of the samples in cement group and 5 (62,5%) of the samples in control group presenting category I or II inflammatory responses that corresponds histopathologically to an inflammatory response that normally occurs in tissues submitted to surgical trauma. There were no histopathological signs of foreign body reaction in none samples of both groups. As for the study of the degree of ossification, the mean ossification in the control group (3.5) was greater than that shown by the cement group (1.0). The control group showed statistically significant (p < 0.01) higher degrees of ossification (mean 3.5 ± 0.5) when compared to the cement group (1.0 ± 0.0). Conclusion: 1) Alpha-tricalcium phosphate bone cement is biocompatible in the mastoid cavity of guinea pigs 2) Alphatricalcium fosfato bone cement undergoes bone remodeling but it doesn´t present osteoconductive properties
229

Metallographic, gas and energy dispersive x-ray analyses of osteosynthesis plates and screws and dental implants removed from patients with clinical indication = Análise metalográfica, de gases e espectrometria por energia dispersiva de raios-x de placas e parafusos para osteossíntese e de implantes dentários removidos de pacientes com indicação clínica / Análise metalográfica, de gases e espectrometria por energia dispersiva de raios-x de placas e parafusos para osteossíntese e de implantes dentários removidos de pacientes com indicação clínica

Pinto, Clarice Maia Soares de Alcântara, 1986- 12 December 2013 (has links)
Orientador: Márcio de Moraes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-24T07:46:17Z (GMT). No. of bitstreams: 1 Pinto_ClariceMaiaSoaresdeAlcantara_M.pdf: 1620980 bytes, checksum: 1e0ec8457d9b0d64bf078cf763f07f37 (MD5) Previous issue date: 2013 / Resumo: O objetivo do presente trabalho foi avaliar a microestrutura e a composição química dos implantes dentários, placas e parafusos para osteossíntese removidos de pacientes em casos com indicação clínica. No trabalho 1, foram realizadas análises metalográfica, de gases e de espectrometria por energia dispersiva de raios-X de placas e parafusos de titânio utilizados para osteossíntese e removidos de 30 pacientes. Os prontuários destes pacientes foram avaliados para obtenção de dados referentes à idade, gênero, procedimento cirúrgico que havia motivado a inserção das placas e parafusos para osteossíntese, a razão clínica para remoção e o tempo de permanência destes dispositivos in situ. Quarenta e oito placas e 238 parafusos foram removidos no total. Infecção consistiu na principal causa para remoção destes dispositivos, correspondendo a 43.3% dos casos. O principal sítio do qual as placas e os parafusos foram removidos foi a mandíbula, equivalendo a 66.6% dos casos. Todas as placas e parafusos analisados estavam dentro das normas F67 e F136 da ASTM (American Society for Testing and Materials) de acordo com a análise metalográfica e a espectrometria por energia dispersiva de raios-X. Na análise de gases, cinco amostras apresentaram valores acima do regulamentado pela ASTM para os elementos Hidrogênio e/ou Oxigênio. A partir do estudo, pôde-se concluir que as propriedades físicas e químicas das amostras não estavam associadas à condição clínica que ocasionou a remoção destes dispositivos e que o tempo de permanência destes implantes in situ não determinou alterações em suas propriedades. No trabalho 2, foram realizadas análises metalográfica e de espectrometria por energia dispersiva de raios-X para avaliação de 38 implantes dentários de titânio removidos de 29 pacientes com indicação clínica. Os prontuários destes pacientes foram avaliados para obtenção de dados referentes à idade, gênero, razão clinica para remoção e tempo de permanência dos implantes. Falta de osseointegração sem sintomatologia ou sinais de infecção associados foi a principal causa para falha dos implantes, correspondendo a 55.1% dos casos. A maxila foi o sítio de falha dos implantes dentários em dezessete pacientes (58.6%) enquanto doze pacientes (41.4%) apresentaram falha de implantes instalados na mandíbula. Todos os implantes analisados eram constituídos de titânio comercialmente puro e apresentaram-se dentro da norma F67 da ASTM. A partir do estudo, pôde-se concluir que as propriedades físicas e químicas dos implantes dentários analisados não estavam associadas ao insucesso no tratamento e à falha destes dispositivos / Abstract: The aim of this study was to evaluate the microstructure and chemical composition of dental implants, bone plates and screws removed from patients in cases of clinical indication. In the first study, metallographic, gas and energy dispersive X-ray analyses were performed to evaluate osteosynthesis plates and screws retrieved from 30 patients. The medical records of these patients were evaluated to obtain data regarding age, gender, surgical procedure that had motivated the insertion of osteosynthesis plates and screws, the reason for removal and the period of time of these devices in situ. Forty-eight plates and 238 screws were removed in total. Infection was the main reason for these devices removal, representing 43.3% of cases. Mandible was the main site for plates and screws removal, corresponding to 66.6% of cases. All plates and screws analyzed were within the specifications F67 and F136 of ASTM (American Society for Testing and Materials) according metallographic and energy dispersive X-ray analyses. In gas analysis, five samples had hydrogen and/or oxygen values above the regulated by ASTM. From the study, it was concluded that the physical and chemical properties of the samples were not associated with the clinical condition that caused the removal of these devices, and retention time of these implants did not determine changes in their properties. In the second study, metallographic and energy dispersive X-ray analyses were performed for evaluation of 38 dental implants removed from 29 patients with clinical indication. Medical records of these patients were evaluated to obtain data regarding age, gender, reason for removal and period of time in situ. Lack of osseointegration without symptomatology or signs of infection was the main reason for dental implants failure, corresponding to 55.1% of cases. Maxilla was the site of implants failure in seventeen patients (58.6%) while twelve patients (41.4%) had failure of dental implants installed in mandible. All dental implants analyzed were manufactured of commercially pure titanium and were within the ASTM F67 specification. From the study, it was concluded that physical and chemical properties of dental implants analyzed were not associated with failure of these devices. / Mestrado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Mestra em Clínica Odontológica
230

Výroba dentálních náhrad / On the production of dental parts

Lekeš, Jonáš January 2013 (has links)
Tato práce popisuje části dentálních náhrad, lékařské pojmy, které se s nimi vážou a vysvětluje proces a problematiku koncepce a výroby těchto částí. Různé druhy biomateriálů jako kovy, keramika, polymery či kompozity jsou zde popsány, hlavní důraz je však kladen na titanové a chrom kobaltové slitiny a korozivzdorné oceli. Experimentální část nabízí 2 řešení zlepšení výroby součásti. První část experimentální části se zabývá zlepšením kvality styčné plochy pilíře zvýšením hustoty síťování součásti. Druhá část nabízí nahrazení operace frézování operací vrtání. Byly vybrány nástoje od 4 výrobců. Pro nalezení vhodného nástroje jsou provedeny 2 testy vrtání a vybrán nástroj vhodný pro obrábění titanové a chrom kobaltové slitiny.

Page generated in 0.077 seconds