• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 174
  • 56
  • 11
  • 7
  • 7
  • 7
  • 7
  • 7
  • 5
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 281
  • 140
  • 134
  • 127
  • 97
  • 85
  • 76
  • 70
  • 41
  • 39
  • 35
  • 31
  • 29
  • 28
  • 26
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
231

Osseointegração de implantes com diferentes macro e microestruturas instalados em áreas sem enxertia ou com osso bovino desproteinizado associado ou não à medula óssea fresca : estudo pré-clínico em coelhos /

Leocádio, Amanda de Carvalho Silva January 2020 (has links)
Orientador: Elcio Marcantonio Junior / Resumo: Implantes com diferentes macro (CI-Implante Cilíndrico e HCI-Implante Cônico Híbrido) e microestruturas (NP-Jateamento+ataque ácido e AQ-Jateamento+ataque ácido+imersão em solução isotônica de cloreto de sódio 0,9 %) foram testados em áreas de osso nativo ou enxertadas prévia ou imediatamente com osso bovino desproteinizado associado ou não à medula óssea fresca (DBB e DBB/BM). Na primeira hipótese foi testado a estabilidade primária e o processo de osseointegração em implantes com diferentes macroestruturas (CI vs. HCI) na metáfise tibial de coelhos. 24 coelhos foram divididos em 3 períodos (2, 4 e 8 semanas). Cada animal recebeu bilateralmente 2 implantes de cada grupo. Todos os implantes foram avaliados quanto ao torque de inserção. Um dos implantes foi submetido ao torque de remoção e análise histológica e o outro foi utilizado para análise microtomográfica e histométrica (%BIC-Contato Osso-Implante). Os HCI apresentaram maior torque de inserção (32.93±10.61 Ncm vs. 27.99± 7.80Ncm) e maior %BIC no período de 8 semanas (79.08±11.31% vs. 59.72±11.29%) que CI. CI apresentaram maiores valores de torque de remoção que HCI no período de 8 semanas (91.05 ± 9.32 Ncm vs. 68.62 ± 13.70 Ncm). Não houve diferenças em relação aos dados microtomográficos. Na segunda e na terceira hipóteses, foi avaliado a influência de diferentes macros (CI vs. HCI) e microestruturas de implantes (NP vs. AQ) no processo de osseointegração em áreas previamente (metáfise tibial e seio maxilar) ou imediat... (Resumo completo, clicar acesso eletrônico abaixo) / Doutor
232

Biokompatibilita implantabilních materiálů se zaměřením na titanové dentální implantáty / Biocompatibility of Implantable MaterialsFocused on Titanium Dental Implants

Moztarzadeh, Amin January 2017 (has links)
This dissertation thesis deals with the evaluation of biocompatibility and osseointegration of nanostructured titanium materials used for dental implants. Bulk material topography and surface modification of titanium are currently of intense research mainly due to the significant impact on biocompatibility and improvement of osseointegration of dental implants. In the theoretical part are described types of titanium material and different methods of its surface modification. In vitro and in vivo biocompatibility and osseointegration tests are described as well. The experimental work consists of two parts of experiments. In the first experiment, we examined how grain size of nanostructured titanium material influences the behaviour of fibroblastic as well as osteoblastic cells growth on its surface. The experimentally obtained data were statistically analysed and discussed. Grain size was proven to be an important factor that influenced not only the strength of material but also its interactions with cells. The second experiment describes current methods used in the experimental evaluation of osseointegration of dental implants. The results of histological staining methods are illustrated and compared. A standardized and reproducible technique for stereological quantification of bone-implant contact...
233

Osseointegration of Temporary Anchorage Devices Using Recombinant Human Bone Morphogenetic Protein-2

Cruz, Erin E 01 May 2010 (has links) (PDF)
Over the past 5 years, the use of titanium implants as temporary anchorage devices (TADs) has become an important tool in clinical orthodontic practices. The use of TADs have provided orthodontists a way of moving teeth against fixed objects rather than against the surrounding teeth, which tend to counteract desired motion. At present, viable attachment of TADs involves direct insertion through gingival tissue and piercing of the bone. Surface modifications such as sandblasted and acid-etched treatment or bone morphogenetic protein surface treatment, however, can be applied to the TADs to promote enhanced osseointegration, thereby allowing the TADs to serve as stable anchors while avoiding bone puncture. In this study, a comparison was made between sandblasted/acid-etched TADs and sandblasted/acid-etched/recombinant human bone morphogenetic protein-2 (rhBMP-2) treated TADs to determine whether rhBMP-2 promotes enhanced osseointegration. A total of 10 rats (4 controls and 6 treated with rhBMP-2) were used in the study, with 1 TAD placed on the skull of each rat. At the end of 6 weeks, the animals were euthanized by carbon dioxide asphyxiation, and bone blocks, each containing a TAD, were prepared for histological examination and biomechanical characterization. The results of this study showed that TADs treated with rhBMP-2 had greater bone formation at the bone-implant interface and an increase in total implant stability.
234

Desenvolvimento de dois modelos de mini-implantes e componentes protéticos: correlação da macroestrutura e propriedades mecânicas / Development of two models of mini-implants and prosthetic components: macrostructure correlation and mechanical properties

Valente, Mariana Lima da Costa 19 January 2018 (has links)
O edentulismo acomete grande parcela da população mundial, especialmente os idosos, gerando perda da função mastigatória, desordens nutricionais, estética desfavorável e redução da qualidade de vida. Como alternativa a esses problemas, as overdentures implanto retidas tem representado uma modalidade de tratamento eficiente para reabilitação da mandíbula. Assim, o presente estudo teve por objetivo desenvolver e avaliar a efetividade de dois modelos de mini-implantes dentários e um componente protético, cápsula de retenção para overdentures mini-implante retidas. Para tal, um total de 30 mini-implantes (n=10) foram utilizados: modelo comercial Intra-Lock® System, experimental rosqueado e experimental helicoidal. Ambos os mini-implantes desenvolvidos no estudo foram confeccionados em titânio Grau IV, nas dimensões de Ø 2,0 mm x 10 mm de comprimento e submetidos a tratamento de superfície nanométrico. O desempenho dos mesmos foi comparado ao modelo comercial selecionado quanto à estabilidade primária, por meio de torque de inserção e ensaio de arrancamento e à distribuição de tensões, através dos métodos fotoelástico e de correlação de imagens digitais (CID). Foram realizados carregamentos puntiformes axiais e oblíquos (inclinação de 30º do modelo), com cargas de 100 N para a fotoelasticidade e de 250 N axial e 100 N oblíquo para a CID. Para análise do componente protético foi utilizado o teste de resistência à fadiga. 60 cápsulas (n=20): Poliacetal, Politetrafluoretileno (PTFE) e o-ring convencional (Intra-Lock®) foram capturadas aos pares, com resina acrílica e submetidas a 3625 ciclos de inserção/remoção, simulando 30 meses de uso da overdenture. A deformação interna e externa dos componentes foi avaliada por meio de Estereomicroscópio Óptico. Os dados obtidos foram submetidos a ANOVA e teste de Tukey (&alpha;=0,05). O torque de inserção (TI) e ensaio de arrancamento apresentaram significância estatística para todos os modelos (p<0,05), sendo o TI maior para o mini-implante rosqueado e a força máxima de arrancamento para o modelo Intra-Lock®. Quanto à análise de tensões por meio da fotoelasticidade verificou-se de maneira geral, maiores tensões no terço médio e apical dos mini-implantes. O mesmo padrão foi observado para a CID, porém, neste caso, com tensões significativamente maiores (p<0,05) para os mini-implantes rosqueados na condição de carregamento axial, para o oblíquo não foram encontradas diferenças significativas (p>0,05). Quanto à análise dos componentes protéticos, a cápsula de poliacetal apresentou a maior retenção (p<0,05), seguida do o-ring e PTFE. Menor deformação foi observada para o o-ring (p<0,05) e maior deformação interna (p<0,05), após a realização da fadiga, para o poliacetal. O mini-implante rosqueado apresentou de modo geral estabilidade primária e distribuição de tensões comparável ao modelo comercial avaliado. O componente protético de poliacetal demonstrou superioridade em relação ao o-ring da Intra-Lock® quanto à força de retenção e apesar da maior deformação interna sofrida, sugere-se sua substituição após no mínimo 30 meses de uso da overdenture / Edentulism affects a large part of the world population, especially the elderly, generating loss of masticatory function, nutritional disorders, unfavorable esthetics and reduction of quality of life. As an alternative to these problems, overdentures implant retained have represented an efficient treatment modality for mandibular rehabilitation. Thus, the present study aimed to develop and evaluate the effectiveness of two models of dental mini-implants and a prosthetic component, retention caps for overdentures mini-implant retained. To do this, a total of 30 mini-implants (n=10) were used: Intra-Lock® System commercial model, experimental threaded and experimental helical. Both mini-implants developed in the study were made in Titanium Grade IV, in the dimensions of Ø 2.0 mm x 10 mm in length and submitted to a nanometric surface treatment. Their performance were compared to the commercial model selected for primary stability by means of insertion torque and pullout test and stress distribution using photoelastic and digital image correlation (DIC) methods. Axial and oblique punctiform loads (30º inclination of the model) were performed, with loads of 100 N for photoelasticity and 250 N axial and 100 N oblique for DIC. For the analysis of the prosthetic component, the fatigue strength test was used. 60 capsules (n=20): Polyacetal, Polytetrafluoroethylene (PTFE) and conventional O-ring (Intra-Lock®) were captured in pairs with acrylic resin and subjected to 3625 insertion/removal cycles, simulating 30 months of overdenture use. The internal and external deformation of the components was evaluated using an Optical Stereomicroscope. Data were submitted to ANOVA and Tukey\'s test (&alpha;=0.05). The insertion torque (IT) and pullout test were statistically significant for all models (p<0.05), with IT being highest for the threaded mini-implant and maximum pulling force for the Intra-Lock® model. As for stress analysis by photoelasticity, it was generally observed that there were higher tensions in the middle and apical third of the mini-implants. The same pattern was observed for the DIC, but in this case, with significantly higher stresses (p<0.05) for the mini-implants threaded in the axial loading condition, no significant differences were found for the oblique (p>0.05). As for the analysis of prosthetic components, the polyacetal caps presented the highest retention (p<0.05), followed by o-ring and PTFE. Lower deformation was observed for o-ring (p<0.05) and greater internal deformation (p<0.05), after fatigue, for polyacetal. The threaded mini-implant generally showed primary stability and strain distribution comparable to the commercial model evaluated. The polyacetal prosthetic component showed superiority over the Intra-Lock® o-ring for the retention force and despite the greater internal deformation suffered, it is suggested to replace it after at least 30 months of overdenture use
235

Reparação óssea sobre superfícies de titânio usinadas ou tratadas por óxido de titânio com exerto autógeno em bloco coberto por membrana reabsorvível / Healing of bone on machined or grit-blasted titanium surfaces with autogenous block graft covered with resorbable membrane

Hespanhol, Andre Micheletti 14 September 2009 (has links)
Este estudo avaliou, quantitativamente, o osso regenerado após técnica de regeneração óssea guiada, utilizando osso autógeno em bloco e membrana de colágeno e descreveu seu processo de reparação ao redor de superfícies de implantes usinadas ou tratadas por jato de óxido de titânio em períodos de até 150 dias. Foram utilizados 60 ratos machos Wistar, divididos em 2 grupos: um recebeu implantes com superfície usinada (U) e o outro recebeu implantes com superfície tratada por jato de óxido de titânio (T). Uma trefina foi utilizada para a remoção do enxerto ósseo em bloco da calvária do animal. O enxerto foi fixado próximo ao ângulo da mandíbula do rato, na cortical vestibular, com o uso do implante. O conjunto foi coberto por membrana de colágeno. A ortotanásia foi realizada em 0, 14, 21, 45 e 150 dias. Foi realizado processamento histológico para material nãodescalcificado, e um corte no longo eixo do implante foi obtido para cada espécime. Foram realizadas análises qualitativa e quantitativa. Os dados foram analisados estatisticamente, em um nível de significância de 5%, pelos testes de Kruskal-Wallis e de Dunn. Os resultados relativos aos períodos de observação mostraram que a média do tamanho do defeito inicial foi de DO-U = 604,13 m e DO-T = 585,90 m (p=0,720) e que a média de espessura inicial do leito foi de EL-U = 257,29 m e ELT = 243,57 m (p=0,07); houve uma redução da espessura do enxerto no período de 150 dias para o grupo T em relação ao grupo U (EE-T = 338,25 m; EE-U = 407,71m) (p=0,003), não havendo outras diferenças significativas entre os grupos. Notou-se a presença de osso regenerado, vestibularmente ao enxerto, a partir de 21 dias, com uma nítida tendência ao aumento de sua espessura até o período de 150 dias, onde notamos um aumento da espessura óssea total de cerca de 4,6 (T) e 4,8 (U) vezes a espessura original da mandíbula, com valores de ETTO U = 1254,40 m e ETTO T = 1141,85 m (p=0,48). / This study quantitatively analyzed the regenerated bone after guided bone regeneration technique using autogenous block graft with resorbable membrane and described its pattern around machined titanium or oxide grit-blasted titanium surfaces in periods of up to 150 days. Sixty male, adult, Wistar rats were randomly assigned to one of two groups: machined titanium surface (U) or oxide grit-blasted titanium surface (T). A block graft was harvested from the rat calvarium with a trephine, laid and stabilized on the external cortex near the angle of the mandible with implants. A collagen membrane was adapted to completely cover the bone graft in both groups. The animals were euthanized at 0, 14, 21, 45 and 150 days after surgery. Nondecalcified histological sections were processed for each specimen and one section on the long axis of the implant was obtained. Qualitative and quantitative analysis were carried out. Statistical analyses were carried out with a significance level of 5% and used Kruskal-Wallis and Dunn tests. Results showed that the mean bone defect was DO-U = 604,13 m and DO-T = 585,90 m (p=0,720), and the mean mandible bone width was EL U = 257,29 m and EL-T = 243,57 m at zero hour. The mean graft width was reduced after 150 days for the T group as compared to group U (EET = 338,25 m and EE-U = 407,71 m) (p=0,003). No other significant differences between groups were observed. Regenerated bone was observed buccal to the bone graft after 21 days increasing in width after 150 days. The final mean mandible bone width after 150 days (ETTO-U = 1254,40 m and ETTO-T = 1141,85 m) achieved 4,8 (U) and 4,6 (T) times the original mandible width (p=0,48).
236

Osseointegração de implantes em defeitos circunferenciais utilizando proteínas angiogênicas purificadas do látex, osso autógeno e regeneração óssea guiada. Estudo comparativo em mandíbulas de cães / Implant osseointegration in circumferential bone defects using latexderived proteins, autogenous bone graft and guided bone regeneration. A comparative study in the dog mandible

Arnez, Maya Fernanda Manfrin 22 January 2009 (has links)
Diversas pesquisas têm direcionado esforços na busca de biomateriais que fossem capazes de melhorar a osseointegração e a estabilidade de implantes dentais em regiões anatômicas desfavoráveis. Entretanto, muitas das opções de terapias regenerativas, largamente empregadas em cirurgias orais reconstrutivas, estão associadas à algumas desvantagens clínicas como um grande período de recuperação, alto risco de morbidade, risco de parestesia nos pacientes, além de apresentarem alto custo. Biomateriais obtidos a partir do látex natural extraído da Hevea brasilienses (seringueira) demonstraram apresentar propriedades angiogênicas e significante aumento no reparo ósseo de alvéolos dentais e em defeitos de calota de ratos. Considerando os benefícios da angiogênese no processo de reparação óssea, o objetivo deste trabalho foi avaliar a capacidade osteogênica proporcionado pelas proteínas angiogênicas do látex na otimização do processo de osseointegração e na estabilidade de implantes de titânio instalados em defeitos ósseos cicunferenciais. Dez cães foram submetidos às cirurgias de instalação de implantes no centro de defeitos ósseos, após a exodontia dos pré-molares. Os defeitos ósseos em cada animal foram preenchidos com coágulo, osso autógeno, proteínas angiogênicas do látex associada ao gel carreador ou gel carreador (apenas gel de colágeno associado ao ácido hialurônico, sem a presença de implante). Em um dos lados da mandíbula os implantes foram recobertos por membrana não absorvível de e-PTFE sem reforço de titânio, ao passo que no lado contralateral, os implantes foram recobertos apenas pelo retalho mucoperiosteal. Metade dos animais foram sacrificados após 4 semanas e o restante após 12 semanas pós-operatórias. A estabilidade dos implantes foi avaliada através de análise de freqüência de ressonância e a formação óssea foi analisada por meio de histologia, histomorfometria, análise qualitativa e quantitativa de fluorescência. Os resultados numéricos obtidos foram submetidos à análise de variância (ANOVA) e contrastes ortogonais foram realizados para comparações múltiplas. Histologicamente, observou-se para todos os biomateriais, uma formação de osso imaturo e lamelar no tempo de 4 e 12 semanas, respectivamente. Na análise qualitativa de fluorescência, encontrou-se maior atividade óssea no período inicial de avaliação (p&le;0,05). A membrana não mostrou efeito significativo no processo de regeneração óssea e não houve diferença estatística entre os diferentes biomateriais testados (p&ge;0,05). O gel carreador apresentou menor formação óssea quando comparado aos demais materiais, sem considerar o tempo e a presença da membrana (p&le;0,05). Houve um aumento significativo da formação óssea, osseointegração e da estabilidade ao longo do tempo para os diferentes biomateriais empregados (p&le;0,05), independente da presença da membrana. O grupo das proteínas angiogências do látex mostraram formação óssea similar ao coágulo e ao osso autógeno em 4 e 12 semanas, respectivamente (p&ge;0,05). Os biomateriais obtiveram significante formação óssea, osseointegração e estabilidade dos implantes ao longo do período de avaliação experimental. Esta pesquisa mostrou que a regeneração óssea guiada não alterou os resultados histométricos, as proteínas angiogênicas do látex promoveram deposição óssea similar ao coágulo e osso autógeno nos defeitos alveolares, observou-se um aumento do processo de ossoeintegração e da estabilidade dos implantes em todos os sítios experimentais, independente do tratamento instituído. / The development of biomaterials that can assist osseointegration and implant stability in dissatisfactory anatomical regions has been the goal of several researches in the past years. Despite the array of regenerative therapies to be used, some clinical disadvantages still persist, such as considerable patient morbidity, extended patient recovery periods, substantial cost, risk of paresthesia and residual defects in the donor site. Natural latex biomaterials from Hevea brasiliensis (rubber tree) have shown promising advantages, such as angiogenic properties, significantly high bone repair in dental alveoli, easy acquisition and handling, biocompatibility, reduced cost, dispensability of donor sites and very little chance of morbidity. Considering the well-known benefits of angiogenesis in the bone healing process, the purpose of this study was to evaluate the osteogenic capacity of angiogenic latex proteins in accelerating osseointegration and implant stability, when placed in circumferential bone defects. Ten male dogs were underwent an implant placement in center of the defects after pre-molar extractions. The circumferential gaps around the implant were filled either with coagulum, particulate autogenous bone graft, latex angiogenic proteins mixed in a gel carrier, or with collagen and hyaluronic acid gel carrier without implants. Circumferential defects were covered with a non-absorbable e-PTFE membrane on one side and left uncovered on the other. Half the animals were sacrificed 4 and 12 weeks after implant placement. Implant stability was evaluated using resonance-frequency analysis and bone formation was analyzed by histological, histometric, qualitative and quantitative bone labeling analysis. Data were analyzed statistically using ANOVA and orthogonal contrasts for multiple comparisons. Immature and lamellar bone were observed at 4 and 12 weeks, respectively. Bone labeling analysis showed more bone activity on early period of healing (p&le;0.05). The membrane did not show significant effect on bone regeneration and there was not statistical difference among the different biomaterials, considering the different time evaluation periods (p&ge;0.05). Gel carrier group showed less bone formation than other filling materials, not considering recovery time and membrane (p&le;0.05). Latex angiogenic proteins showed bone regeneration similar to coagulum and bone graft at 4 and 12 weeks, respectively (p&ge;0.05). There was significant bone formation, osseointegration and implant stability of biomaterials during the entire healing period. This research showed that guided bone regeneration technique did not change the histometric results; latex angiogenic proteins promoted bone deposition similar to coagulum and bone graft on alveolar bone defects; osseointegration process and implant stability occurred in all experimental sites, regardless of the treatment performed.
237

Eficácia na remoção da necrose óssea térmica: realizada por implantes osseointegráveis com câmaras coletoras / Removal effectiveness of thermal osteonecrosis: performed by osseointegrated implants with collecting chambers

Barbosa, Bruno Aiello 28 June 2013 (has links)
Durante a confecção do alvéolo, promove-se o aumento da temperatura da broca devido à fricção, aquecendo o tecido ósseo adjacente e seus componentes celulares, podendo provocar a Necrose Óssea Térmica. A necrose óssea térmica deteriora a porção orgânica do tecido ósseo (tanto matriz óssea como as células), bem como as células diferenciadas e indiferenciadas presentes na circulação sanguínea e medula óssea local. Alguns trabalhos demonstraram que o aquecimento ósseo acima de 47oC por 1 minuto provoca tal fenômeno. Atualmente existem variações na técnica de perfuração com objetivo de diminuir o grau de aquecimento e aumentar as taxas de sucesso dos tratamentos reabilitadores. Sabemos que nem todos os profissionais são cautelosos em utilizar materiais de qualidade e que mesmo os materiais com qualidade, após repetido uso, perdem a eficácia. Seria ideal que o implante osseointegrável gerenciasse a remoção destas áreas de necrose óssea térmica, independentemente da execução correta da técnica de perfuração e da qualidade das brocas. Com isso, garantiríamos que o tecido ósseo poderia se reparar ao redor dos implantes da melhor maneira possível. Neste trabalho avaliamos a eficácia de 3 modelos de implante com câmaras coletoras funcionais diferentes, em tecido ósseo de minipig. O implante com câmara coletora interna demonstrou-se 37,22% mais eficaz que o implante com câmaras externas e 3 arestas cortantes, quando os alvéolos eram confeccionados sem irrigação e com brocas desgastadas. O implante com câmaras coletoras externas e 4 arestas também demonstrou-se eficaz, porém manteve 83,75% das células viáveis enquanto que no grupo com câmaras internas este resultado foi de 91,39%. / The manufacture of the alveolus can increase the temperature of the drill due to friction heating the adjacent bone tissue and its cellular components, this phenomenon is known by thermal osteonecrosis. The thermal osteonecrosis deteriorates the organic portion of bone (bone matrix and cells), as well as undifferentiated and differentiated cells circulating in the blood and bone marrow. Some studies have demonstrated that bone heating above 47oC for 1 minute causes this phenomenon. Currently there are variations in drilling technique aiming to reduce the heating degree and increase the success rates of rehabilitation treatments. We know that not all professionals are cautious of using quality materials and even the materials with quality after repeated use, lose their effectiveness. Would be ideal that implants manages and removes these areas with thermal osteonecrosis, regardless of the technique of implementing the drilling and the quality of drills. With this, we ensure that bone tissue could possibly repair around implants in the best way. In this study we evaluated the efficacy of 3 implant models with different functional collecting chambers in minipigs bone tissue. The implant with internal collection chamber proved to be 37.22% more effective than the implant with external chambers and three sharp edges, when the alveolus were manufactured without irrigation and uncut drills. The implant with external collecting chambers and four sharp edges also showed an effective but 83.75% of the cells remained viable while in the group with internal chambers this result was 91.39%.
238

Ticp e liga Ti-13Nb-13Zr com diferentes tratamentos de superfície-testes in vitro e in vivo / Ticp and Ti-13Nb-13Zr alloy with different surface treatments in vitro and in vivo tests

Carola Gomez Agreda 12 April 2013 (has links)
O titânio e suas ligas são biomateriais metálicos extensamente utilizados em aplicações médicas e odontológicas, apesar de não formarem ligação química com o osso circundante. Por isto é desejável técnicas que proporcionem a bioatividade na superfície desses metais. A proposta deste estudo foi avaliar e comparar, por testes in vitro e in vivo o comportamento de Ticp e da liga Ti-13Nb-13Zr utilizando diferentes tratamentos de superfície frente à formação do recobrimento biomimético e ao processo de osteointegração. Foram utilizadas placas comerciais de Ti e amostras da liga e de Ticp, obtidas por M/P. As amostras foram submetidas a quatro diferentes tratamentos de superfície (padrão - tratamento alcalino; 1°- tratamento alcalino e térmico; 2°- tratamento ácido e alcalino; 3º- tratamento alcalino, CaCl2, térmico e água quente), analisadas quanto à formação de apatita em SBF em períodos de 1 a 21 dias. Os recobrimentos obtidos foram caracterizado por MEV e DRIFT. Para a avaliação in vivo dos implantes, obtidos por M/P, de Ticp e da liga, com e sem tratamentos superficiais, foram utilizados coelhos adultos machos. A avaliação teve duração de 7 semanas em que foram aplicados marcadores celulares ósseos em tempos e sequência específicos do pós-operatório. Na avaliação in vitro, os recobrimentos de maior espessura foram nas amostras obtidas por M/P, comparativamente à amostra laminada. Todos os tratamentos foram efetivos na promoção da bioatividade. O 2º tratamento obteve recobrimento com maior espessura nos períodos avaliados para todas as superfícies. Na avaliação in vivo, ocorreu crescimento ósseo com osteointegração em todos os implantes com e sem tratamentos superficiais. O crescimento ósseo na interface osso/implante ocorreu de forma contínua em todo o período de reparação para o Ticp, o Ticp com tratamento padrão, o Ticp com o 2º tratamento e a liga com o 1° tratamento; e ocorreu de forma mais intensa no primeiro e terceiro período de reparação para os demais implantes. Os resultados dos testes in vitro e in vivo não são passíveis de analogia direta neste estudo, pois forneceram informações importantes sobre a formação, morfologia e taxa de aposição do recobrimento aos diferentes tratamentos de superfície e a efetividade da osteointegração destes tratamentos de superfície em modelo animal. / Titanium and its alloys are widely used metallic biomaterials in medical and dental applications for patient rehabilitation. However, these materials cannot bond with surrounding bone. For this reason, it is desirable to provide a bone-bonding ability for metallic surface. The aim of this study was to evaluate and compare in vitro and in vivo tests of Ti and Ti-13Nb-13Zr alloy subjected to different surface treatments. Laminate titanium plates and Ti and alloy Ti samples obtained by powder metallurgy were used in this study. The samples were subjected to four different surface treatments (pattern- alkali treatment; 1°- alkali and heat treatments; 2°- acid and alkali treatments; 3°- alkali, CaCl2,heat and hot water treatments) and evaluated for apatite coating in SBF for periods of 1 to 21 days. The coated specimens were analyzed by SEM (surface and cross section) and DRIFT. For in vivo evaluation of osseointegration were used Ticp and alloy implants obtained by powder metallurgy with and without surface treatments in male adult rabbits. The evaluation was 7 weeks which were applied bone cell markers at selected times. In vitro evaluation, surfaces obtained by powder metallurgy had a coating of greater thickness when compared to the laminate surface. All treatments were effective in promoting the bioactivity. The 2nd treatment provided coating thicker in the evaluation periods for all surfaces. The osseointegration occurred in all implants with and without surface treatments. However, growth in the bone/ implant interface was continued all over repair period for Ticp, Ticp with pattern treatment, Ticp with 2nd treatment and alloy with 1st treatment. Bone growth in interface occurred more intensely for first and third period to repair for remaining implants. In vitro and in vivo tests are not liable to direct analogy in this study because provided important information on the formation, morphology and apposition rate of coating on different surface treatments and the effectiveness of osseointegration in animal model.
239

Avaliação da estabilidade primária de implantes convencionais e modificados por meio de ensaios de desempenho, frequência de ressonância e análise microestrutural / Evaluation of primary stability of conventional and modified implants by the performance tests, resonance frequency and microstructural analysis

Valente, Mariana Lima da Costa 09 October 2014 (has links)
A estabilidade primária dos implantes odontológicos é determinante para a osseointegração e depende dos fatores qualidade, quantidade óssea e tipo de implante. O objetivo desse estudo foi avaliar a influência do formato de implantes convencionais e modificados e do tipo de substrato na estabilidade primária por meio da correlação de ensaios de desempenho e frequência de ressonância e análise microestrutural. No estudo foram utilizados 54 implantes Neodent®: 27 cilíndricos, sendo 9 hexágono externo (Titamax Ti Cortical - 4,0 mm x 11 mm), 9 hexágono interno (Titamax II Plus - 3,75 mm x 11 mm) e 9 cone morse (Titamax CM - 4,0 mm x 11 mm); e 27 implantes cônicos de 4,3 mm x 10 mm, sendo 9 hexágono externo (Alvim Ti), 9 hexágono interno (Alvim II Plus) e 9 cone morse (Alvim CM). Os implantes foram inseridos em osso artificial da marca Nacional® nas densidades de 15, 20 e 40 PCF e osso de costela suína. Para os ensaios de desempenho foi quantificado o torque de inserção com um torquímetro digital e a força máxima de arrancamento utilizando uma Máquina Universal de Ensaios. Para avaliar a frequência de ressonância foi utilizado o aparelho Ostell® e para a análise morfológica um Microscópio Eletrônico de Varredura, sob aumentos de 40 e 100 vezes. Após a realização dos ensaios com os implantes convencionais, os modelos Alvim CM e Titamax Ti Cortical (n=9) tiveram sua morfologia externa alterada com a prolongação dos chanfros desde o terço apical até o nível da plataforma protética e foram submetidos aos mesmos testes propostos para os parafusos originais. Verificada a normalidade dos dados utilizou-se o teste de análise de variância ANOVA, comparação de médias Tukey (&alpha;=5%) e correlação de Pearson. Para os implantes convencionais, o Alvim CM apresentou maior média em todos os ensaios realizados, sendo estatisticamente diferente dos implantes cilíndricos quando analisado o torque de inserção no osso (73,33 N.cm) e força de arrancamento na poliuretana de 40 PCF (910,36 N) e osso (553,79 N). Os implantes Titamax II Plus tiveram as menores médias, diferente estatisticamente dos cônicos quando analisado o torque de inserção (22,22 N.cm) e frequência de ressonância no osso (72,83 ISQ) e força de arrancamento na poliuretana de 40 PCF (61,97 N) e osso (86,40 N). A análise dos ensaios de desempenho e frequência de ressonância apresentou correlação moderada de acordo com o p de Pearson (0,30 a 0,70) e a comparação entre as fotomicrografias não mostrou alteração morfológica dos implantes. A modificação realizada no parafuso Alvim CM proporcionou um aumento significativo no torque de inserção (p=0,000), diminuição das médias de arrancamento (p=0,000) e manteve semelhança com as médias de frequência de ressonância (p=0,169) quando comparado ao implante convencional. O Titamax Ti modificado aumentou significativamente o torque de inserção (p=0,043) e provocou diminuição significativa para a frequência de ressonância (p=0,002) e ensaio de arrancamento (p=0,000). Conclui-se que o formato dos implantes interfere na estabilidade primária, sendo os implantes cônicos indutores de maior estabilidade. A análise de correlação das metodologias empregadas demonstrou a associação positiva das mesmas para complementação da análise da estabilidade primária / The primary stability of dental implants is critical for osseointegration and depends on factors quality, bone quantity and type of implant. The aim of this study was to evaluate the influence of conventional and modified implants and the type of substrate shape on primary stability through the correlation of performance tests and frequency of resonance and microstructural analysis. In the study 54 Neodent® implants were used: 27 cylindrical, 9 hexagonal (Titamax Ti Cortical - 4.0 mm x 11 mm), 9 internal hexagon (Titamax II Plus - 3.75 mm x 11 mm) and 9 morse taper (Titamax CM - 4.0 mm x 11 mm); and 27 tapered implants of 4.3 mm x 10 mm and 9 external hexagon (Alvim Ti), 9 internal hexagon (Alvim II Plus) and 9 morse taper (Alvim CM). The implants were inserted into artificial bone of National ® brand at densities of 15, 20 and 40 PCF and pork rib bone. For testing the performance was quantified insertion torque with a digital torque meter and the maximum pullout strength using a universal testing machine. To evaluate the resonance frequency was used Ostell ® device and the morphological parsing an Scanning Electron Microscope under increases of 40 and 100 times. After the tests with conventional implants, models CM Alvim and Titamax Cortical Ti (n=9) had their external morphology changed with the prolongation of the bevels from the apical to the level of prosthetic platform and underwent the same tests proposed for the original screws. Checked for normality of the data used in the test of ANOVA, Tukey comparison (&alpha;=5%) and Pearson correlation. For conventional implants, the CM Alvim showed higher average in all tests, with statistically different when analyzed cylindrical implant insertion torque on bone (73.33 N.cm) and pullout strength in polyurethane 40 PCF (910.36 N) and bone (553.79 N). Implants Titamax II Plus had the lowest average, statistically different when analyzed the tapered insertion torque (22.22 N.cm) and resonance frequency in bone (72.83 ISQ) and pullout strength in 40 PCF polyurethane (61.97 N) and bone (86.40 N). The analysis of the performance tests and had moderate resonance frequency correlation according op Pearson (0.30 to 0.70) and comparing the photomicrographs showed no morphological alteration of the implants. The modification made to the screw Alvim CM provided a significant increase in insertion torque (p=0.000), decrease of average pullout (p=0.000) and remained similar to the average resonance frequency (p=0.169) when compared to the implant conventional. The Titamax Ti modified significantly increased insertion torque (p=0.043) and caused a significant decrease in the resonance frequency (p=0.002) and pullout test (p=0.000). It is concluded that the shape of the implants interfere with the primary stability, with the inductors tapered implants stability. Correlation analysis of the methodologies used showed a possible association of these for further analysis of primary stability
240

Hidroxiapatita deficiente em cálcio associada a BMP para tratamento de defeito crítico em ulna de Gallus gallus domesticus

Gutiérrez, Letícia Gutiérrez de January 2017 (has links)
Fraturas cominutivas com grandes perdas ósseas são comuns em animais silvestres, sendo de maior prevalência em aves, devido a traumas, com a crescente urbanização e desmatamento. Um dos problemas para o tratamento dessas fraturas nesses animais é a dificuldade do uso de enxertia autógena, devido os locais de coleta não oferecerem material suficiente e pela alta taxa de morbidade. Assim, a engenharia de biomateriais vem desenvolvendo diversos dispositivos com a intenção de auxiliar nesse tratamento. O uso de cimento ósseo é crescente nesse meio, e tem como objetivo a recuperação e reintrodução do animal a seu habitat. O objetivo deste trabalho foi avaliar o uso do cimento ósseo de hidroxiapatita deficiente em cálcio (HAD) associado ou não a proteína morfogenética óssea (BMP), para o tratamento do defeito crítico (DC) diafisário em ulna de galinhas domésticas. Foram utilizadas 32 aves, separadas em 4 grupos de 8 animais, sendo: controle negativo (GCN), controle positivo (GCP), cimento de HAD (GHAD) e cimento HAD associado a BMP (GHAD+BMP). Todos os animais passaram pelos procedimentos de ostectomia e a fixação dos fragmentos por meio da colocação de um pino intramedular de 1,5mm de forma retrógada, e acompanhados por período de 60 dias. Foram realizados exames radiográficos, análise histopatológica e biomecânica das ulnas. O presente trabalho demonstrou que não houve diferença significativa de consolidação entre os grupos com e sem BMP, porém o HAD+BMP apresentou-se mais eficiente para DC em galinhas na avaliação histopatológica, levando a resposta osteoindutora, por parte do cimento, e osteogênica, pela proteína. / Comminuted fractures with great bone loss are common in wild animals, being more present in birds due to trauma related to growing urbanization and deforestation. One of the problems of the treatment of these kinds of fractures in these animals is the difficulty of using autogenous grafting because collection places do not offer enough material and also because of the high morbidity rate. Therefore, biomaterials engineering has been developing several devices intending to help on this treatment. Therewith, the use of bone cement is increasing in this environment, and has as its goal the recovery and reintroduction of the animal to its habitat. The objective of this work was to evaluate the use of calcium deficient hydroxyapatite bone cement (HAD) for the treatment of diaphysialcritical defect (DC) in ulna of domestic hens. Thirty-two birds were used, divided in four groups of eight animals, being: negative control (GCN), positive control (GCP), HAD cement (GHAD) and HAD cement associated with bone morphogenetic protein (GHAD + BMP). All animals went through the procedure of ostectomy and fixation of the fragments by placing a 1.5mm intramedullary pin in a retrograde way, and assisted for a period of 60 postoperative days. Radiographic examinations, histopathological and biomechanical analysis of the ulna were performed.The present paper demonstrated that there was not a significant consolidation measure between the groups with no BMP, however HAD + BMP presented more efficient results for DC in hens in the histopathological evaluation, leading to an osteoinductive response by cement and osteogenic by the protein.

Page generated in 0.1401 seconds