• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 81
  • 43
  • 24
  • 20
  • 13
  • 4
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 231
  • 231
  • 94
  • 74
  • 67
  • 38
  • 35
  • 34
  • 33
  • 27
  • 26
  • 22
  • 19
  • 19
  • 18
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
221

Application of Polymeric Hollow-Fiber Membranes in Air Filtration / Application of Polymeric Hollow-Fiber Membranes in Air Filtration

Bulejko, Pavel January 2019 (has links)
Membrány z dutých vláken jsou široce využívány v aplikacích týkajících se úpravy kapalin jako např. při čištění odpadních vod, v membránových kontaktorech a bioreaktorech, membránové destilaci apod. I když jsou často využívány při separacích směsí plynů, je jejich použití pro mechanickou filtraci aerosolů velmi vzácné. Tato práce se zabývá filtrací vzduchu pomocí polypropylenových membrán z dutých vláken včetně jejich filtrační účinnosti, tlakových ztrát a také zanášením při dlouhodobé filtraci. Filtrační účinnost byla proměřena za použití různých aerosolů jako TiO2 a síran amonný. Tlakové ztráty byly měřeny při různých konfiguracích, tj. různé filtrační ploše a průměru vlákna membrány. Zanášení membrán bylo testováno použitím normovaného prachu definovaného normou ANSI/ASHRAE 52.2. Predikční modely pro filtrační účinnost a permeabilitu/tlakovou ztrátu membrány byly aplikovány na parametry membrán z dutých vláken a porovnány. Tyto membrány mají velikost pórů kolem 90 nm a poměrně nízkou porositu a tím vysoký potenciál pro separaci nanočástic ze vzduchu. Dále byla provedena analýza filtračního koláče a vyhodnocení energetických nároků a porovnány s teoretickými modely. V závěru práce je nastíněn odhad ceny životního cyklu při filtraci pomocí těchto membrán.
222

Automatizované pracoviště pro měření vzduchotechnických veličin / Automatized working place for measuring of airflow parameters

Smělý, Jakub January 2013 (has links)
This thesis describes the design work for the measurement of air values. The first part describes the airflow, pressure build-up in pipes and losses due to airflow losses. There is also a description of fans and explain their characteristics depending on the pressure generated by airflow. The next part describes the design of the measuring chamber, electronics and control for fully automatic measurement of air quantities.
223

Upgrading Biogas to Biomethane Using Absorption

Dixit, Onkar 17 November 2015 (has links)
Questions that were answered in the dissertation: Which process is suitable to desulphurize biogas knowing that chemical absorption will be used to separate CO2? Which absorption solvent is suitable to separate CO2 from concentrated gases such as biogas at atmospheric pressure? What properties of the selected solvent, namely aqueous diglycolamine (DGA), are already known? How to determine solvent properties such as equilibrium CO2 solubility under absorption and desorption conditions using simple, but robust apparatuses? What values do solvent properties such as density, viscosity and surface tension take at various DGA contents and CO2 loadings? How do primary alkanolamine content and CO2 loading influence solvent properties? What is the optimal DGA content in the solvent? What is the optimal desorption temperature at atmospheric pressure? How can equilibrium CO2 solubility in aqueous DGA solvents be simulated? What is the uncertainty in the results? How to debottleneck an absorber and increase its gas-treating capacity? How to determine the optimal lean loading of the absorption solvent? What are the characteristics of the absorption process that uses aqueous DGA as the solvent to separate CO2 from biogas and is more energy efficient and safer than the state-of-the-art processes? How to quantitatively compare the hazards of absorption solvents? What is the disposition of the German population towards hazards from biogas plants? What are the favourable and adverse environmental impacts of biomethane? / Fragen, die in der Dissertation beantwortet wurden: Welches Verfahren ist zur Entschwefelung von Biogas geeignet, wenn die chemische Absorption zur CO2-Abtrennung genutzt wird? Welches Absorptionsmittel ist geeignet, um CO2 aus konzentrierten Gasen, wie Biogas, bei atmosphärischem Druck abzutrennen? Welche Eigenschaften des ausgewählten Absorptionsmittels, wässriges Diglykolamin (DGA), sind bereits bekannt? Wie wird die CO2-Gleichgewichtsbeladung unter Absorptions- und Desorptionsbedingungen mit einfachen und robusten Laborapparaten bestimmt? Welche Werte nehmen die Absorptionsmitteleigenschaften wie Dichte, Viskosität und Oberflächenspannung bei verschiedenen DGA-Gehalten und CO2-Beladungen? Wie werden die Absorptionsmitteleigenschaften durch den Primäramin-Gehalt und die CO2-Beladung beeinflusst? Was ist der optimale DGA-Gehalt im Absorptionsmittel? Was ist die optimale Desorptionstemperatur bei atmosphärischem Druck? Wie wird die CO2-Gleichgewichtsbeladung im wässrigen DGA simuliert? Welche Ungenauigkeit ist zu erwarten? Wie wird eine Absorptionskolonne umgerüstet, um die Kapazität zu erweitern? Wie wird die optimale CO2-Beladung des Absorptionsmittels am Absorbereintritt (im unbeladenen Absorptionsmittel) bestimmt? Was sind die Prozesseigenschaften eines Absorptionsverfahrens, das wässriges DGA als Absorptionsmittel nutzt sowie energieeffizienter und sicherer als Verfahren auf dem Stand der Technik ist? Wie kann das Gefahrenpotenzial von Absorptionsmittel quantitativ verglichen werden? Wie werden Gefahren aus einer Biogasanlage durch die deutsche Bevölkerung wahrgenommen? Welche positive und negative Umweltauswirkung hat Biomethan?
224

adix_Masters_thesis_FINAL.pdf

Adam John Dix (14210324) 05 December 2022 (has links)
<p> Wire-wrapped rod bundles are often used in nuclear reactors operating in a fast neutron spectrum, as designers seek to minimize neutron scattering by packing the fuel pins into a hexagonal lattice. Bundles with many rods have extensively been studied as representative of large fuel assemblies, however far fewer experiments have investigated bundles with 7 rods (7-pin bundles). The large difference in subchannel number between these bundles leads to 7-pin bundles having different pressure drop characteristics. The Versatile Test Reactor (VTR) sodium cartridge loop proposes to use a 7-pin bundle as its experimental core region, highlighting the need for additional data and models. The current work seeks to establish a better understanding of the pressure drop in 7-pin wire-wrapped rod bundles through scaled experiments and a novel pressure drop model. A scaling analysis is first performed to demonstrate the applicability of water experiments to the VTR sodium cartridge loop, before an experimental test facility is designed and constructed. Experiments are then performed at a range of Reynolds numbers to determine the pressure drop. Current models are able to predict the data well, but are complex and can be difficult to use. A comparatively simpler model is developed, based on exact laminar solutions of a simplified rod bundle, which also offers a theoretical lower bound for the pressure drop in wire-wrapped bundles. The proposed model compares well with the existing experimental database, able to predict bundle friction factor with an average absolute percent difference of 10.8%. This accuracy is also similar to existing correlations, while relying on fewer empirical coefficients. The theoretical lower bound is also used to identify several datasets in literature that may feature data that is systemically lower than the true pressure drop, which agrees with previous observations in literature. </p>
225

Development of Universal Databases and Predictive Tools for Two-Phase Heat Transfer and Pressure Drop in Cryogenic Flow Boiling Heated Tube Experiments

Vishwanath Ganesan (7650614) 03 August 2023 (has links)
<p>In this study, universal databases and semi-empirical correlations are developed for cryogenic two-phase heat transfer and pressure drop in heated tubes undergoing flow boiling.</p>
226

Treatment of dissolved metals in highway runoff water : Pilot-scale trial with four reactive filter media and sand filter / Rening av lösta metaller i dagvatten från motorvägar : Försök i pilotskala med fyra reaktiva filtermaterial och sandfilter

Bianchi, Serena January 2021 (has links)
The increasing highway traffic is leading to higher and higher levels of pollutants in the stormwater, such as suspended solids, metals, oils, nutrients and PAH. This runoff water causes the degradation of water bodies quality, leading to increased interest in the treatment of highway runoff for the removal of contaminants. Traditional treatments mostly consist of sedimentation, aimed primarily at the removal of suspended solids and particlebound contaminants. Recently the concern has shifted to the dissolved and colloidal fractions of contaminants as well, metals in particular, which makes reactive media filters a potentially interesting technology for runoff water treatment. However, very little research has been carried out on this technology so far, mostly in batch laboratory experiments with synthetic runoff water. This study aims at investigating the performance of four reactive media filters (Petrit T, Polonite, D-Rainclean and Filtralite-P) and a defined filter sand used for water processing at removing dissolved and particulate-bound metals. To achieve the goal, a pilot plant has been constructed in Gröndal, south of Stockholm, inside the existing Gröndalsmagasin, a full-scale stormwater treatment plant. The catchment area is located mostly on the E4 and Essingeleden, the highest trafficked motorway in Sweden with an AADT of 140 000 vehicles. A pump feeds the pilot plant from the Gröndalsmagasin outlet, after the stormwater has been treated with flocculation and sedimentation, and collects such water in a collection vessel. The five filter media columns are fed during runoff events with a flow scaled proportionally to the influent in the Gröndalsmagasin to mimic real conditions of flow and pollutant concentrations. Field measurements of pH, turbidity and conductivity, have been carried out during the trial. Samples have also been collected with flow proportional samplers connected to the collection vessel and the outlet of the five columns, as well as in the form of grab samples from sample ports at different depths in the columns. These samples have been sent to ALS Scandinavia AB to perform lab analysis. The pH in the effluent of the reactive filter media increased to values between 10 and 13, and slowly decreased during the trial. No difference was found between the pH in Filtersand outlet and the influent water. All materials showed excellent performance at removal of dissolved and particulate-bound Zn as well as particulate-bound Cu. Dissolved Cu was removed effectively by reactive media, and to a minor extent by Filtersand. Leaching of metals was observed from three materials: Filtersand released Mn during April, Polonite released Cr, with a very good correlation with the Chloride content and Petrit-T released Ba during the entire trials. / Den ökande vägtrafiken leder till allt högre halter av föroreningar i dagvattnet, till exampel suspenderade ämnen, metaller, oljor, närings ämnen och PAH. Detta dagvatten försämrar degradering av vattenförekomsternas kvalitet, vilket har lett till ett ökat intresse för rening av dagvatten fr ̊ån motorvägar för att avlägsna föroreningar. Traditionella behandlingar består oftast av sedimentering, som främst syftar till att reducera suspenderade ämnen och partikelbundna föroreningar. På senaste tiden har intresset förskjutits till att även omfatta lösta och kolloidala fraktioner av föroreningar, speciellt metaller, vilket gör reaktiva filtermaterial till en potentiellt intressant teknik f ̈or behandling av dagvatten. Mycket lite forskning har dock gjorts om denna teknik hittills, då oftast i laboratorieexperiment med syntetiskt dagvatten. Denna studie syftar till att undersöka hur fyra reaktiva mediafilter (Petrit T, Polonite, D-Rainclean och Filtralite-P) och en typ av sandfilter fungerar när det gäller att avlägsna lösta och partikelbundna metaller. F ̈or att uppnå målet har en pilotanläggning byggts i Gröndal, söder om Stockholm, inuti det existerande Gröndalsmagasinet, ett dagvattenreningsverk i full skala. Avrinningsområdet ligger vid E4 och Essingeleden, den mest trafikerade motorvägen i Sverige med en ÅDT på 140 000 fordon. En pump matar pilotanläggningen fr ̊ån Gröndalsmagasinets utlopp, efter att dagvattnet har behandlats med flockning och sedimentering, och samlas upp detta vatten i ett uppsamlingskärl. De fem filtreringskolonnerna matas under avrinningshändelserna med ett flöde som är proportionellt till inflödet till Gröndalsmagasinet för att imitera verkliga förhållanden av flöde och föroreningskoncentrationer. Mätningar av pH, turbiditet och konduktivitet har utförts under försöket. Prover har också samlats in med flödesproportionella provtagare som är kopplade till uppsamlingskärlet och utloppet fr ̊an de fem kolonnerna, samt i form av grabbprover fr ̊an provtagningsöppningar på olika djup i kolonnerna. Dessa prover har skickats till ALS Scandinavia AB för laboratorieanalys. pH-värdet i utflödet fr ̊ån det reaktiva filtermediet ökade till värden mellan 10 och 13 och sjönk långsamt under försöket. Ingen skillnad hittades mellan pH-värdet i filtrets utlopp och inflödesvattnet. Alla material visade mycket goda resultat när det gäller avlägsnande av löst och partikulät bundet Zn samt partikulärt bundet Cu. Lösta Cu avlägsnades mycket effektivt av reaktiva medier och i mindre utsträckning av Filtersand. Läckage av metaller observerades fr ̊ån tre material: Filtersand släppte ut Mn under April, Polonite släppte ut Cr, med en mycket god korrelation med kloridhalten och Petrit-T släppte ut Ba under hela försöket.
227

Transient integral boundary layer method to simulate entrance flow conditions in one-dimensional arterial blood flow / Zeitabhängige Integralrandschichtmethode zur Simulation von eindimensionalen arteriellen Blutströmungen im Einlassbereich

Bernhard, Stefan 12 October 2006 (has links)
No description available.
228

Moderní technologické prvky pro trubkové výměníky tepla / Modern technological elements for tubular heat exchangers

Plánková, Tereza January 2020 (has links)
The aim of this diploma thesis is to get acquainted with modern technological elements currently used in shell-and-tube heat exchanger in the shell-side and tube-side, thermal-hydraulic calculation of selected elements and comparison of thermal-hydraulic properties with classically used competing technological elements. The work deals mainly with EM baffle in the tube-side and tube inserts like the twisted tape type (and its modifications) and coiled wire in the tube-side. The theoretical part is focused on acquaintance with classical technological elements in shell-and-tube heat exchanger and with basic thermal-hydraulic calculations, practical part then on acquaintance with modern elements and thermal-hydraulic calculation of selected elements. These calculations are then compared with the results of the thermo-hydraulic calculation of similar elements.
229

Compact air separation system for space launcher / Compact air separation system demonstrator for space launchers using in-fight oxygen collection

Bizzarri, Didier 01 September 2008 (has links)
A compact air separator demonstrator based on centrifugally enhanced distillation has been studied. The full size device is meant to be used on board of a Two Stage To Orbit vehicle launcher. The air separation system must be able to extract oxygen in highly concentrated liquid form (LEA, Liquid Enriched Air) from atmospheric air. The LEA is stored before being used in a subsequent rocket propulsion phase by the second stage of the launcher. Two reference vehicles are defined, one with a subsonic first stage and one with a supersonic first stage. In both cases, oxygen collection is performed during a cruise phase (M 0.7 and M 2.5 respectively). The aim of the project is to demonstrate the feasibility of the air separation system, investigate the separation cycle design, and assess that the separator design selected is suitable for the reference vehicles.<p><p>The project is described from original base ideas to design, construction, extended testing and analysis of experimental results. Preliminary computations for a realistic layout have been performed and the motivations for the choices made during the process are explained. Test rig design, separator design and technical discussion are provided for a subscale pilot unit. Mass transport parameters and flooding limits have been estimated and experimentally measured. Performance has been assessed and shown to be sufficient for the reference Two Stage To Orbit vehicles. The technology developed is found suitable without further optimization, although some volume and mass reduction would be desirable for the supersonic first stage concept. There are many ways of optimisation that can be further investigated. The aim of this program, however, is not to fully optimize the device, but to demonstrate that a device based on a simple, robust, low-risk design is already suitable for the launch vehicles. On top of that analysis, directions for improvements are suggested and their potentials estimated. A complete assessment of those improvements requires further maturation of the technological concept through further testing and practical implementations.<p><p>Directions for future work, general conclusions and a vehicle development roadmap have also been provided.<p> / Doctorat en Sciences de l'ingénieur / info:eu-repo/semantics/nonPublished
230

微粒子スラリーのろ過設計に関する研究 / ビリュウシ スラリー ノ ロカ セッケイ ニカンスル ケンキュウ

吉田 友一, Yuichi Yoshida 01 March 2018 (has links)
粉体の微粒子化に伴い,固液分離操作の中でも高精度かつ多量処理が可能なろ過の重要性はますます高まっている.しかしながら,微粒子スラリーのろ過抵抗は非常に大きく,所望の処理能力を得られないことが多い.本論文では,ろ過操作設計におけるろ材抵抗,スラリー凝集・分散状態,ケークろ過抵抗の予測に関して数値シミュレーションを利用した検討を行うことで,微粒子スラリーのろ過抵抗の低減に有用な知見を得ることができた. / 著者名の「吉」は「土」の下に「口」の置き換え / 博士(工学) / Doctor of Philosophy in Engineering / 同志社大学 / Doshisha University

Page generated in 0.0217 seconds