Avaliação do trauma intracoclear causado pela inserção do feixe de eletrodos do implante coclear via fossa média em ossos temporais / Evaluation of intra cochlear trauma after cochlear implant electrode insertion through a middle fossa approach in temporal bonesJuan Carlos Cisneros Lesser 01 February 2017 (has links)
Introdução: O acesso pela via da fossa craniana média para colocação do implante coclear provou ser uma alternativa valiosa em pacientes com otite média crônica e cavidades de mastoidectomia instáveis, cócleas parcialmente ossificadas e em alguns casos de displasia do ouvido interno. Até hoje não existem pesquisas que descrevam se a inserção do feixe de eletrodos pela via da fossa média pode ser feita com um mínimo de traumatismo intracoclear, comparável ao observado nas inserções pela janela redonda. Objetivo: Avaliar o trauma intracoclear com dois modelos distintos de implante quando o feixe de eletrodos é inserido por cocleostomia na fossa craniana média em ossos temporais. Método: 20 ossos temporais retirados antes de 24 horas pós-óbito, foram implantados através do local da cocleostomia no giro basal da cóclea identificado no assoalho da fossa cerebral média. Dez peças receberam um implante reto e dez um pré-curvado, e foram fixadas em resina epóxi. Foi realizada tomografia computadorizada para determinar a colocação adequada do feixe eletrodos, profundidade de inserção e a distância entre a janela redonda e a cocleostomia. Por último, as peças foram polidas em série, tingidas e visualizadas por estereomicroscópio para avaliar a posição do feixe e trauma intracoclear. Resultados: A tomografia mostrou um posicionamento intracoclear do feixe de eletrodos nas 20 peças. No grupo dos implantes retos a média de eletrodos inserido foi 12,3 (10 a 14) e dos pré-curvados 15,1 (14 a 16) com uma diferença significativa (U=78, p=0,0001). A mediana de profundidade de inserção foi maior para o eletrodo pré-curvado (14,5mm) que para o reto (12,5mm) com diferenças estatisticamente significativas (U = 66, p = 0,021). Só uma das 20 inserções foi atraumática e 70% tiveram graus de trauma altos (grau 3 ou 4). Não foram observadas diferenças significativas do grau de trauma entre os dois tipos de feixes nem quando as inserções foram no sentido da janela redonda, comparado com o sentido do giro médio. Conclusões: A técnica cirúrgica utilizada permitiu a inserção do feixe de eletrodos na cóclea em todas as peças, porém sem garantir uma inserção na escala timpânica e com alto risco de trauma nas microestruturas da cóclea / Introduction: In recent years, a middle fossa approach has been described for the insertion of cochlear implants, and it proved to be a reliable alternative for implantation in patients with chronic supurative otitis media, unstable mastoid cavities with recurrent otorrhea, partially ossified cochlea and in some cases of inner ear dysplasia. Until now, no research has been done to describe if this approach allows for anatomic preservation and non-traumatic insertions comparable to those through the round window. Objective: To evaluate cochlear trauma when the cochlear implant electrode is inserted through a middle fossa approach by means of histologic and imaging studies in temporal bones. Methods: 20 temporal bones retrieved before 24 hours after death were implanted through a middle cranial fossa cochleostomy in the basal turn of the cochlea. Ten received a straight electrode and 10 a perimodiolar electrode. After reducing the bone size with preservation of the inner ear structures, the temporal bones were fixed, dehydrated and embedded in an epoxy resin. CT scans were performed to determine if an adequate direction of insertion was attained, the depth of insertion and the distance between the cochleostomy and the round window. At last, the samples were polished by micro-grinding technique and microscopically visualized to evaluate intracochlear trauma. Results: The CT-scan showed an adequate intracoclear position of the electrode in all the samples. In the straight electrode group the average number of inserted electrodes was 12.3 (10 to 14) against 15.1 (14- 16) for the perimodiolar (U=78, p=0.0001). The median depth of insertion was significantly larger for the perimodiolar electrode group (14.4mm vs. 12.5mm U=66, p = 0.021). Only one atraumatic insertion was achieved and 70% of the samples had important trauma (grades 3 and 4). No differences were identified for the trauma grades between the two groups of electrodes. Also, there were no differences in trauma if the cochlear implants were inserted in the direction of the basal turn of the cochlea or in the direction of the middle and apical turns. Conclusions: The surgical technique that was used allowed for a proper intracochlear insertion of the electrodes in all 20 temporal bones but it does not guarantee a correct scala tympani position and carries high trauma risk for the intracochlear microstructures
|
32 |
Avaliação do trauma intracoclear causado pela inserção do feixe de eletrodos do implante coclear via janela redonda em ossos temporais / Assessment of intracochlear trauma caused by insertion of cochlear implant electrode array via round window in temporal bonesMartins, Graziela de Souza Queiroz 12 May 2014 (has links)
INTRODUÇÃO: A ampliação dos critérios de indicação para cirurgia do implante coclear e os benefícios da preservação da audição residual no pósoperatório estimularam o desenvolvimento de técnicas cirúrgicas atraumáticas. Minimizar os traumas intracocleares durante a inserção do feixe de eletrodos do implante coclear é um passo fundamental para este intuito. O objetivo deste trabalho é avaliar se o trauma intracoclear é diferente quando o feixe de eletrodos do implante coclear é inserido através do quadrante anterossuperior ou anteroinferior da membrana da janela redonda. MÉTODOS: Vinte e cinco ossos temporais frescos de cadáveres humanos foram submetidos à timpanomastoidectomia padrão. Após exposição adequada da membrana da janela redonda, em metade dos ossos o feixe de eletrodos do implante coclear foi inserido via quadrante anterossuperior da membrana da janela redonda, e na outra metade via quadrante anteroinferior. Os ossos temporais foram desidratados e embebidos em epóxi, com o feixe de eletrodos in situ. As peças foram serialmente polidas, tingidas e visualizadas por meio de estereomicroscópio para avaliar o trauma intracoclear causado pela inserção do feixe de eletrodos. As imagens foram fotografadas. RESULTADOS: Em treze ossos temporais o feixe de eletrodos do implante coclear foi inserido via quadrante anterossuperior da membrana da janela redonda, e em doze ossos via quadrante anteroinferior. Obteve-se 372 superfícies. As análises histológicas revelaram diferentes graus de traumas às estruturas intracocleares. Os resultados mostraram que a inserção do feixe de eletrodos via quadrante anterossuperior ou anteroinferior acarretam a mesma frequência de trauma intracoclear. CONCLUSÕES: A presença de trauma intracoclear e a severidade dos traumas ocorridos no tocante à inserção do feixe de eletrodos de implante coclear pelo quadrante anterossuperior e anteroinferior da membrana da janela redonda não apresentou diferença estatisticamente significativa. Observou-se, porém, maior facilidade para exposição cirúrgica do quadrante anterossuperior em relação ao quadrante anteroinferior / INTRODUCTION: The expansion of the indication criteria for cochlear implant surgery and the benefits of preserving residual hearing postoperatively have stimulated the development of atraumatic surgeries. Minimizing the intracochlear traumas during the electrodes insertion is a critical step for this aim. The objective of this study is to assess whether there is a difference in intracochlear trauma when the cochlear implant electrode array is inserted through the anterior-superior or anterior-inferior quadrants of the round window membrane. METHODS: Twenty-five fresh human temporal bones were submitted to standard tympanomastoidectomy. After adequate exposure of the round window membrane, in half of the bones the cochlear implant electrode array was inserted via anterior-superior quadrant of round window membrane and in the other half via anterior-inferior quadrant. The temporal bones were dehydrated and embedded in epoxy with the electrodes array in situ. The specimens were serially polished, stained and viewed through a stereomicroscope to assess the intracochlear trauma caused by insertion of the electrode array. Resulting images were documented. RESULTS: In thirteen temporal bones the cochlear implant electrode array was inserted via anterior-superior quadrant of round window membrane and in twelve bones via anterior-inferior quadrant. Three hundred and seventy two surfaces were obtained. Histological examinations revealed varying degrees of damage to the intracohlear structures. The results showed that the insertion of the electrode array via anterior-superior or anterior-inferior quadrant lead to the same frequency of intracochlear trauma. CONCLUSIONS: The presence of intracochlear trauma and severity of traumas regarding the insertion of cochlear implant electrode array via anterior-superior and via anterior-inferior quadrant of the round window membrane showed no statistically significant difference. However, it was observed that surgical exposure of anterior-superior quadrant was easier than surgical exposure of anterior-inferior quadrant
|
33 |
Efeito nas mudanças temporárias dos limiares auditivos durante o uso de próteses auditivas de alta potência / Effect in the temporary threshold shift during the use of the high power hearing aidVitto, Ursula Maria Lellis de 17 February 2005 (has links)
Alterações temporárias ou permanentes na audição podem ser encontradas nas orelhas submetidas a níveis elevados de pressão sonora. As mudanças temporárias induzidas nas orelhas protetizadas, quando estimuladas por suas próteses auditivas ajustadas na amplificação prescrita, foram avaliadas em um grupo de 25 pacientes após um período controlado (2 a 2 ½ h) de exposição ao ruído presente em um ambiente acústico comum. O estudo foi dividido em três etapas. Uma medida inicial foi realizada na primeira etapa para mensurar a magnitude das mudanças temporárias dos limiares auditivos, induzidas nas 42 orelhas (25 pacientes) durante um período contínuo de exposição ao ruído, com suas próteses auditivas ajustadas na amplificação prescrita. Na segunda etapa, essas 42 orelhas foram divididas em dois grupos distintos: as 22 orelhas protetizadas (13 pacientes) que apresentaram maior mudança temporária inicial nos limiares auditivos foram incluídas no Grupo Experimental e as 20 orelhas protetizadas (12 pacientes) que apresentaram menor mudança temporária inicial nos limiares auditivos foram incluídas no Grupo Convencional. Nesta etapa, as próteses auditivas, adaptadas nas 22 orelhas incluídas no Grupo Experimental, tiveram a sua amplificação reduzida por um período de 60 a 90 dias proposto para o \"treinamento\" das orelhas no uso cotidiano de suas próteses auditivas. Após este período de treino, a amplificação das próteses auditivas retornou ao nível prescrito. No Grupo Convencional, a amplificação prescrita das próteses auditivas adaptadas não foi alterada. Durante esta etapa, quatro medidas das mudanças temporárias induzidas nos limiares auditivos foram realizadas para os dois grupos nas mesmas condições de exposição ao ruído adotadas para a determinação da medida inicial. Uma última medida das mudanças temporárias induzidas nos limiares auditivos foi realizada na terceira etapa, também em idênticas condições. Esta última medida ocorreu em média 30/35 dias depois do término do treinamento, quando os pacientes do Grupo Experimental já faziam o uso cotidiano de suas próteses auditivas reajustadas na amplificação prescrita. A análise estatística de variância (ANOVA) comparou o comportamento das mudanças temporárias induzidas nos limiares auditivos nas três etapas do estudo. Para as orelhas incluídas no Grupo Experimental, foram verificadas alterações estatisticamente significantes (f<0,05) durante as etapas do estudo. As mudanças temporárias induzidas nos limiares auditivos das orelhas incluídas no Grupo Experimental aumentaram nos primeiros quinze a trinta e cinco dias após o inicio do treinamento. Com a continuidade do treinamento essas alterações foram gradualmente se reduzindo. As mudanças temporárias induzidas no final do treinamento (etapa pós-experimental) foram as menores observadas durante o estudo. A redução teve inicio nas freqüências abaixo de 1000 Hz e se extendeu na faixa de freqüência mais afetada nas orelhas protetizadas durante a exposição inicial ao ruído ambiente (250 a 2000 Hz). Para as orelhas incluídas no Grupo Convencional não foram constatadas alterações estatisticamente significantes (f>0,05) nas mudanças temporárias induzidas nos limiares auditivos quando avaliadas nas mesmas condições de exposição ao ruído ambiente. Entretanto, para as freqüências mais graves (250 Hz), foi verificada uma tendência a redução nestas alterações no decorrer do estudo / It is well known that the temporary threshold shift in hearing sensitivity is the most obvious hearing effect of the high level acoustic stimulation. Temporary threshold shifts induced in the aided ears were measured in 25 patients after the use of the hearing aids fitted in the prescribed gain during a controlled exposition time (2 a 2 ½ h) to an environmental noise. The study was performed in three phases. In the first phase a first measure of the temporary threshold shift was obtained for 42 aided ears (25 patients) in order to measure the initial amount of temporary threshold shift induced by the hearing aids fitted in the prescribed acoustic gain. In the second phase the ears were included into two study groups: The Experimental Group (EG) formed by 22 ears (13 patients) with greater temporary threshold shift in the initial measure and the Conventional Group(CG) , formed by 20 ears with the shorter temporary threshold shift in the initial measure . The hearing aids amplification in the 22 aided ears of the Experimental Group was reduced during the daily use for a \"training\" period of about 60 to 90 days, and after that was turned to the prescribed gain. The prescribed gain was not modified to the 20 ears of the Conventional Group. Four measure of temporary threshold shift were performed in the second phase when the patients included in the two groups were exposed to an environmental noise in the same conditions used to obtain the initial measure. The last measure (post-experimental phase) of the temporary threshold shift was performed in the same conditions , 30 days in average after the patients of Experimental Group had returned to use their hearing aids in the prescribed gain. In the Experimental Group, the analysis of the variance (ANOVA) showed significant differences(f<0,05) in the amount of induced temporary threshold shifts measured during the three phases of the study. Fifteen or thirteen five days after the training had begun the amount of temporary threshold shift increase, but with the continuous training it was gradually to reduced .In the end of the study, the last measure (post-experimental phase) was performed and the amount of temporary thresholds shift was very shorter. This reduction of temporary threshold shift was initially verified in the frequencies below 1000 Hz and at the end of the study all of the frequencies initially affected during the exposition time to the environmental noise (250 to 2000 Hz) were significantly reduced. In the ears included in the Conventional Group it was not verified temporary threshold shift statistically significant (f>0,05) in any moment, but in the low frequencies (250 Hz) it was noticed a gradually reduction of the amount of temporary threshold shift during the period of this study
|
34 |
Avaliação do trauma intracoclear causado pela inserção do feixe de eletrodos do implante coclear via janela redonda em ossos temporais / Assessment of intracochlear trauma caused by insertion of cochlear implant electrode array via round window in temporal bonesGraziela de Souza Queiroz Martins 12 May 2014 (has links)
INTRODUÇÃO: A ampliação dos critérios de indicação para cirurgia do implante coclear e os benefícios da preservação da audição residual no pósoperatório estimularam o desenvolvimento de técnicas cirúrgicas atraumáticas. Minimizar os traumas intracocleares durante a inserção do feixe de eletrodos do implante coclear é um passo fundamental para este intuito. O objetivo deste trabalho é avaliar se o trauma intracoclear é diferente quando o feixe de eletrodos do implante coclear é inserido através do quadrante anterossuperior ou anteroinferior da membrana da janela redonda. MÉTODOS: Vinte e cinco ossos temporais frescos de cadáveres humanos foram submetidos à timpanomastoidectomia padrão. Após exposição adequada da membrana da janela redonda, em metade dos ossos o feixe de eletrodos do implante coclear foi inserido via quadrante anterossuperior da membrana da janela redonda, e na outra metade via quadrante anteroinferior. Os ossos temporais foram desidratados e embebidos em epóxi, com o feixe de eletrodos in situ. As peças foram serialmente polidas, tingidas e visualizadas por meio de estereomicroscópio para avaliar o trauma intracoclear causado pela inserção do feixe de eletrodos. As imagens foram fotografadas. RESULTADOS: Em treze ossos temporais o feixe de eletrodos do implante coclear foi inserido via quadrante anterossuperior da membrana da janela redonda, e em doze ossos via quadrante anteroinferior. Obteve-se 372 superfícies. As análises histológicas revelaram diferentes graus de traumas às estruturas intracocleares. Os resultados mostraram que a inserção do feixe de eletrodos via quadrante anterossuperior ou anteroinferior acarretam a mesma frequência de trauma intracoclear. CONCLUSÕES: A presença de trauma intracoclear e a severidade dos traumas ocorridos no tocante à inserção do feixe de eletrodos de implante coclear pelo quadrante anterossuperior e anteroinferior da membrana da janela redonda não apresentou diferença estatisticamente significativa. Observou-se, porém, maior facilidade para exposição cirúrgica do quadrante anterossuperior em relação ao quadrante anteroinferior / INTRODUCTION: The expansion of the indication criteria for cochlear implant surgery and the benefits of preserving residual hearing postoperatively have stimulated the development of atraumatic surgeries. Minimizing the intracochlear traumas during the electrodes insertion is a critical step for this aim. The objective of this study is to assess whether there is a difference in intracochlear trauma when the cochlear implant electrode array is inserted through the anterior-superior or anterior-inferior quadrants of the round window membrane. METHODS: Twenty-five fresh human temporal bones were submitted to standard tympanomastoidectomy. After adequate exposure of the round window membrane, in half of the bones the cochlear implant electrode array was inserted via anterior-superior quadrant of round window membrane and in the other half via anterior-inferior quadrant. The temporal bones were dehydrated and embedded in epoxy with the electrodes array in situ. The specimens were serially polished, stained and viewed through a stereomicroscope to assess the intracochlear trauma caused by insertion of the electrode array. Resulting images were documented. RESULTS: In thirteen temporal bones the cochlear implant electrode array was inserted via anterior-superior quadrant of round window membrane and in twelve bones via anterior-inferior quadrant. Three hundred and seventy two surfaces were obtained. Histological examinations revealed varying degrees of damage to the intracohlear structures. The results showed that the insertion of the electrode array via anterior-superior or anterior-inferior quadrant lead to the same frequency of intracochlear trauma. CONCLUSIONS: The presence of intracochlear trauma and severity of traumas regarding the insertion of cochlear implant electrode array via anterior-superior and via anterior-inferior quadrant of the round window membrane showed no statistically significant difference. However, it was observed that surgical exposure of anterior-superior quadrant was easier than surgical exposure of anterior-inferior quadrant
|
35 |
Análise molecular do gene da conexina 26 em pacientes com deficiênica auditiva sensorioneural não-sindrômicaPiatto, Vânia Belintani 28 November 2003 (has links)
Made available in DSpace on 2016-01-26T12:51:55Z (GMT). No. of bitstreams: 1
vaniapiatto_tese.pdf: 1479841 bytes, checksum: 96e04c84851d635167398b1a4196d2fe (MD5)
Previous issue date: 2003-11-28 / Mutações no gene que codifica a proteína conexina 26 têm contribuído para a maioria das deficiências auditivas pré-lingual, sensorioneural não-sindrômicas recessivas. Uma mutação específica, a 35delG, é a mais freqüente das mutações detectadas no gene GJB2 nos vários grupos étnicos estudados. O objetivo foi determinar a prevalência de mutações no gene GJB2 em pacientes com deficiência auditiva sensorioneural não sindrômica, do Serviço de Otorrinolaringologia da FAMERP, em São José do Rio Preto, SP. Trinta e três casos-índice foram avaliados por exames fisico e complementares para excluir formas sindrômicas e causas ambientais da deficiência auditiva e, pela reação em cadeia da polimerase alelo-específico (AS-PCR) para a detecção da mutação 35delG. Os pacientes heterozigotos para a mutação 35delG e aqueles que não tiveram a mutação detectada foram submetidos, posteriormente, ao PCR para detecção da mutação A(GJB6-D 1381830) e ao sequenciamento automático direto para análise da região codificante do gene GJB2. A mutação 35delG foi detectada em 27,3% dos casos-índice (9/3 3) ou em 2 1,2% dos alelos (14/66). A mutação A(GJB6-DI3SI 830) foi encontrada em um (3,0%) caso-índice heterozigoto 35delG. O seqüenciamento direto nos casos-índice heterozigotos identificou um paciente (3,0%) com as mutações 35delG/V3 71. As mutações no gene GJB2 são responsáveis por mais de um quarto das deficiências auditivas sensorioneural não-sindrômica na população do estudo e, o teste PCR alelo-específico (AS-PCR) é um método fácil para rastreamento da mutação 35delG e os resultados positivos podem estabelecer o diagnóstico etiológico e aconselhamento genético nos pacientes afetados.
|
36 |
Efeito nas mudanças temporárias dos limiares auditivos durante o uso de próteses auditivas de alta potência / Effect in the temporary threshold shift during the use of the high power hearing aidUrsula Maria Lellis de Vitto 17 February 2005 (has links)
Alterações temporárias ou permanentes na audição podem ser encontradas nas orelhas submetidas a níveis elevados de pressão sonora. As mudanças temporárias induzidas nas orelhas protetizadas, quando estimuladas por suas próteses auditivas ajustadas na amplificação prescrita, foram avaliadas em um grupo de 25 pacientes após um período controlado (2 a 2 ½ h) de exposição ao ruído presente em um ambiente acústico comum. O estudo foi dividido em três etapas. Uma medida inicial foi realizada na primeira etapa para mensurar a magnitude das mudanças temporárias dos limiares auditivos, induzidas nas 42 orelhas (25 pacientes) durante um período contínuo de exposição ao ruído, com suas próteses auditivas ajustadas na amplificação prescrita. Na segunda etapa, essas 42 orelhas foram divididas em dois grupos distintos: as 22 orelhas protetizadas (13 pacientes) que apresentaram maior mudança temporária inicial nos limiares auditivos foram incluídas no Grupo Experimental e as 20 orelhas protetizadas (12 pacientes) que apresentaram menor mudança temporária inicial nos limiares auditivos foram incluídas no Grupo Convencional. Nesta etapa, as próteses auditivas, adaptadas nas 22 orelhas incluídas no Grupo Experimental, tiveram a sua amplificação reduzida por um período de 60 a 90 dias proposto para o \"treinamento\" das orelhas no uso cotidiano de suas próteses auditivas. Após este período de treino, a amplificação das próteses auditivas retornou ao nível prescrito. No Grupo Convencional, a amplificação prescrita das próteses auditivas adaptadas não foi alterada. Durante esta etapa, quatro medidas das mudanças temporárias induzidas nos limiares auditivos foram realizadas para os dois grupos nas mesmas condições de exposição ao ruído adotadas para a determinação da medida inicial. Uma última medida das mudanças temporárias induzidas nos limiares auditivos foi realizada na terceira etapa, também em idênticas condições. Esta última medida ocorreu em média 30/35 dias depois do término do treinamento, quando os pacientes do Grupo Experimental já faziam o uso cotidiano de suas próteses auditivas reajustadas na amplificação prescrita. A análise estatística de variância (ANOVA) comparou o comportamento das mudanças temporárias induzidas nos limiares auditivos nas três etapas do estudo. Para as orelhas incluídas no Grupo Experimental, foram verificadas alterações estatisticamente significantes (f<0,05) durante as etapas do estudo. As mudanças temporárias induzidas nos limiares auditivos das orelhas incluídas no Grupo Experimental aumentaram nos primeiros quinze a trinta e cinco dias após o inicio do treinamento. Com a continuidade do treinamento essas alterações foram gradualmente se reduzindo. As mudanças temporárias induzidas no final do treinamento (etapa pós-experimental) foram as menores observadas durante o estudo. A redução teve inicio nas freqüências abaixo de 1000 Hz e se extendeu na faixa de freqüência mais afetada nas orelhas protetizadas durante a exposição inicial ao ruído ambiente (250 a 2000 Hz). Para as orelhas incluídas no Grupo Convencional não foram constatadas alterações estatisticamente significantes (f>0,05) nas mudanças temporárias induzidas nos limiares auditivos quando avaliadas nas mesmas condições de exposição ao ruído ambiente. Entretanto, para as freqüências mais graves (250 Hz), foi verificada uma tendência a redução nestas alterações no decorrer do estudo / It is well known that the temporary threshold shift in hearing sensitivity is the most obvious hearing effect of the high level acoustic stimulation. Temporary threshold shifts induced in the aided ears were measured in 25 patients after the use of the hearing aids fitted in the prescribed gain during a controlled exposition time (2 a 2 ½ h) to an environmental noise. The study was performed in three phases. In the first phase a first measure of the temporary threshold shift was obtained for 42 aided ears (25 patients) in order to measure the initial amount of temporary threshold shift induced by the hearing aids fitted in the prescribed acoustic gain. In the second phase the ears were included into two study groups: The Experimental Group (EG) formed by 22 ears (13 patients) with greater temporary threshold shift in the initial measure and the Conventional Group(CG) , formed by 20 ears with the shorter temporary threshold shift in the initial measure . The hearing aids amplification in the 22 aided ears of the Experimental Group was reduced during the daily use for a \"training\" period of about 60 to 90 days, and after that was turned to the prescribed gain. The prescribed gain was not modified to the 20 ears of the Conventional Group. Four measure of temporary threshold shift were performed in the second phase when the patients included in the two groups were exposed to an environmental noise in the same conditions used to obtain the initial measure. The last measure (post-experimental phase) of the temporary threshold shift was performed in the same conditions , 30 days in average after the patients of Experimental Group had returned to use their hearing aids in the prescribed gain. In the Experimental Group, the analysis of the variance (ANOVA) showed significant differences(f<0,05) in the amount of induced temporary threshold shifts measured during the three phases of the study. Fifteen or thirteen five days after the training had begun the amount of temporary threshold shift increase, but with the continuous training it was gradually to reduced .In the end of the study, the last measure (post-experimental phase) was performed and the amount of temporary thresholds shift was very shorter. This reduction of temporary threshold shift was initially verified in the frequencies below 1000 Hz and at the end of the study all of the frequencies initially affected during the exposition time to the environmental noise (250 to 2000 Hz) were significantly reduced. In the ears included in the Conventional Group it was not verified temporary threshold shift statistically significant (f>0,05) in any moment, but in the low frequencies (250 Hz) it was noticed a gradually reduction of the amount of temporary threshold shift during the period of this study
|