• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 20
  • 11
  • 5
  • 3
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 44
  • 44
  • 11
  • 10
  • 9
  • 9
  • 8
  • 8
  • 6
  • 6
  • 6
  • 6
  • 6
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Numerical Simulation of Debris Flows Using a Multi-phase Model and Case Studies of Two Well-documented Events

Naqvi, Mohammad Wasif January 2020 (has links)
No description available.
22

Částice plovoucí na volné hladině vln / Floating particles at water waves free surface

Kupčíková, Laura January 2021 (has links)
This master’s thesis deals with analytical and numerical description of surface gravity waves. Wave theories and their influence on water particle movement is described in the theoretical part of the thesis. Water particle moves in the same direction as wave propagation and this phenomenon is called Stokes drift. It has a significant influence on sediment transport and floating particle movement at water free surface. The experimental part consists of wave profile monitoring and water particle tracking in a wave flume with wave generator and beach model. The experimental results are compared with numerical simulation performed in the ANSYS Fluent software. Finally, the wave profiles obtained from simulation are compared with experimental wave profiles extracted by digital image processing.
23

Modeling of Catalytic Channels and Monolith Reactors

Struk, Peter M. January 2007 (has links)
No description available.
24

Análise da aplicação do modelo de fase constante na avaliação da mecânica respiratória em animais durante broncoconstrição. / Analysis of application of constant phase model in the evaluation of respiratory mechanics in animals during bronconconstrição.

Vitorasso, Renato de Lima 20 June 2016 (has links)
A avaliação da mecânica respiratória é realizada comumente por meio de modelagem matemática. Um modelo amplamente utilizado é o de fase constante que se ajusta à impedância respiratória. Uma das variáveis exibidas por equipamentos de ventilação que aplicam o modelo citado é o Coeficiente de Determinação (COD), um medidor do ajuste do modelo. Há algumas situações em que o COD pode apresentar-se baixo, como: sedação superficial, respiração espontânea, perturbações externas e não linearidade. Entretanto, apesar de os valores de COD estarem disponíveis em ventiladores que utilizam os modelos de fase constante, a literatura é escassa em trabalhos que o citem. O objetivo deste trabalho foi analisar o comportamento do COD em uma curva dose resposta de camundongos BALB/c divididos em um grupo controle e um grupo com modelo animal de asma (OVA) e propor uma alternativa caso o modelo de fase constate não possa ser aplicado. Foram encontrados piores ajustes nas doses mais altas, principalmente no grupo OVA. Foi encontrada uma associação entre parâmetros excluídos nas 5 primeiras medidas e doses (p=0,0026) no grupo OVA. Foram excluídas 11 mensurações na última dose enquanto na primeira ou segunda doses apenas 2. O risco relativo para apresentar medidas excluídas entre a última e primeira ou segunda doses foi: 5,5 e IC: 1,30 - 23,26. A problemática de ter-se encontrado diferenças nestes momentos é que estas são as medidas relacionadas aos maiores valores de parâmetros de cada dose e tradicionalmente são os valores apresentados em estudos científicos. Os valores de pressão traqueal máxima média e mínima comportaram-se de maneira similar em termos de discriminação intergrupos, apresentando diferença (p<0,05) nas doses de 0,3 e 1 mg/kg, assim como o Rn . Em termos de substituição, é possível optar pelo uso de valores de pressão traqueal em detrimento aos parâmetros modelados em momentos em que o modelo de fase constante não deveria ser aplicado, a exemplo de valores baixos de COD em momentos de extrema broncoconstrição. A utilização dos valores de pressão traqueal é viável, por não serem obtidos por meio de uma modelagem matemática e sim por mensuração. Portanto, como os parâmetros Rn G e H são obtidos por meio de modelagem matemática e não por mensuração direta, o mau ajuste do modelo significa que os parâmetros modelados não podem ser aplicados na análise da situação em questão. Ademais, como alternativa é possível utilizar valores de pressão mensurados como variável de resposta, ainda que estes não discriminem vias aéreas e parênquima. / Assessment of respiratory mechanics is commonly performed through the application of mathematical models. A widely applied model is the constant phase model, which fits the respiratory impedance. One of the variables presented by ventilators that apply this model is the Coefficient of Determination (COD), it is used to assess the goodness of fit of the model. There are situation where the COD value is low, such as: superficial sedation, spontaneous breathing, external disturbances and nonlinearity. However, despite the COD value are available for ventilators that apply the constant phase model, the literature is still scarce in studies that mention this coefficient. The aim of this study was to analyze the COD behavior in dose response curves of BALB/c mice divided into a control group and animal model of asthma (OVA) and offer an alternative for moments that the constant phase model should not be applied. It was found an association between parameters excluded in the first five measures and doses (p = 0.0026) in the OVA. Eleven measurements were excluded at the last dose while in the first or in the second doses, only two. The relative risk to present excluded measures between the last and first or second doses was 5.5 and CI: 1.30 to 23.26. The problem about the differences found in these moments is that these are the measures associated to higher model parameter\'s values for each dose and traditionally are the values shown in scientific studies. The minimum, mean and maximal values of tracheal pressure behaved similarly on a inter group matter, presenting differences (p<0,05) at these doses: 0.3 and 1 mg/kg. The same pattern was observed for Rn . It is possible to use values of tracheal pressure instead of modeled parameters in moments that the constant phase model should not be applied, like low COD in moments of severe bronchoconstriction. This replacement of parameters through tracheal pressure is possible because tracheal pressure is not obtained via mathematical models but through mensuration. Therefore, as the Rn G e H parameters are obtained through mathematical modeling and not via direct mensuration, the poor adjustment means that these parameters should not be applied on the moments presented on this study. In addition, as an alternative it is possible to use pressure values measured as a variable of response, even if the pressure values are not able to distinguish between airway and parenchyma.
25

Impedância respiratória de entrada: comparação entre os métodos convencional e de wavetube. / Input respiratory impedance: comparison between conventional and wavetube methods.

Mori, Vitor 26 August 2015 (has links)
A impedância respiratória de entrada pode ser obtida pela Técnica das Oscilações Forçadas (FOT) através de dois métodos diferentes: convencional e de wavetube. Nessa dissertação, primeiramente realizamos uma revisão bibliográfica com enfoque nos assuntos de interesse para esse trabalho, como definições e modelagem de impedância, descrições e bases teóricas para a realização dos dois métodos e descrição dos equipamentos utilizados por cada um dos métodos. A partir de dados experimentais da impedância, em camundongos machos do tipo BALB/c normais, obtidos em dois equipamentos diferentes fez-se uma comparação utilizando como base o Modelo de Fase Constante, analisando possíveis divergências e buscando compreender os motivos de eventuais discrepâncias. Um dos equipamentos (flexiVent, SCIREQ, Canadá) emprega o método convencional enquanto o outro equipamento foi desenvolvido pelo grupo do professor Zoltán Hantos, da Universidade de Szeged, Hungria, e se utiliza do método de wavetube. Tal trabalho foi motivado pela ausência de referências bibliográficas que comparam os dois métodos. A análise dos resultados experimentais nos sugere que os parâmetros obtidos para o Modelo de Fase Constante nos dois equipamentos são diferentes e não comparáveis. / The input respiratory impedance can be obtained by two different methods of performing the Forced Oscillations Technique (FOT): conventional and wavetube method. In this dissertation, first we made a literature review focusing on issues of interest to this work, as definitions and models of impedance, description and theoretical basis for the realization of the two methods and description of the equipments used by each method. Using experimental data of impedance in BALB/c male mice, from two different equipments a comparison was made based on the Constant Phase Model, analyzing possible differences between them and trying to understand the reasons for any discrepancies. The first equipment (flexiVent, SCIREQ, Canada) uses the conventional method while the second one, developed by the research group of Professor Zoltán Hantos of the University of Szeged, Hungary, uses the wavetube method. This work was motivated by the lack of literature references comparing the model parameters obtained by both methods. The analysis of experimental results suggests that the equipments are different and not comparable.
26

Ein Beitrag zur Optimierung klinischer Patientenpfade und deren Anwendung auf komplexe Behandlungsfälle am Beispiel der Station Mund-, Kiefer- und Gesichtschirurgie am Universitätsklinikum Dresden / A contribution to the optimization of clinical patient pathways and their application to complex treatment cases using the example of the station of oaral and maxillofacial surgery at the University Medical Center Dresden

Koch, Thomas 08 July 2014 (has links) (PDF)
Um den Kostendruck in medizinischen Versorgungseinrichtungen, getrieben von den Forderungen aus SGB V und DRG, bei gleichzeitiger Patientenzufriedenheit und Behandlungsqualität im komplexen Rahmen gerecht zu werden, ist die Identifizierung von Optimierungspotentialen und deren Realisierung ein wesentlicher Hebel für das Überleben von Krankenhäusern am medizinischen Markt. Der Patientenpfad, der den Kernprozess der Wertschöpfung der medizinischen Dienstleistung im Krankenhaus darstellt, bildet gleichzeitig die "Logistische Kette an medizinische und sozialen Dienstleistungen". Zur Darstellung der komplexen Struktur des Zusammenwirkens von Prozessen und Schnittstellen entwickelt der Autor das Phasenmodell "Gesundheitsversorgungsprozess" (GVP), bestehend aus seinen drei Hauptprozessen prästationärer-, stationärer- und poststationärer Prozess, die durch deren medizinische, logistische, ökonomische und humansoziale Interdisziplinarität charakterisiert werden. Dieses Modell erweist sich als ein tragfähiger Ansatz für die Analyse zur Optimierung von Behandlungspfaden im klinischen Bereich der Mund-, Kiefer- und Gesichtschirurgie (MKG). Im Ergebnis wird ein Vorschlag erarbeitet, der 7 elektive Krankheitsbilder und deren heterogene Prozessstrukturen in einen standardisierten Behandlungspfad MKG überführt. Ausgehend von der Herleitung standardisierter Behandlungspfade und der Definition sogenannter "Standard Operating Procedures" (SOP´s) wird ein Baukastensystem für die medizinische Behandlung bereitgestellt, welches eine konfigurierbare Individualisierung des Behandlungsprozesses für den Patienten garantiert. Mit der detaillierten Analyse und Ableitung der Sollstrukturen klinischer Behandlungspfade am Beispiel der MKG am Uniklinikum Dresden und dern Verknüpfung zu Interdisziplinaritäten unter dem prozessualen Aspekt liefert die Arbeit einen Beitrag zur Prozessoptimierung im Krankenhaus und bildet gleichzeitig einen Beitrag zur Modellierung für ein modellgestütztes, evidenzbasiertes Prozessmanagement. / To meet the cost pressures in medical care facillities, driven by the demands of the volume V of the German Social Code and DRG, while patient satisfaction and quality of care in complex organizational requirements, the identification of optimization potentials and its realization is an essential lever for the survival of hospitals on the medical market. The patient pathway, which is the core process of the value added chain of medical services at the hospital, froms the "Logistical chain for medical and social services" at the same time. To illustrate the complexity of the interaction of processes and interfacesthe author develops the phase madel "Health Care Process" (HCP) consisting of its three madical and care main processes pre-clinical; clinical and post-clinical process, characterized by their medical, logistical, economic and human social interdisciplinary. This model proves to be a viable approach for the analysis for the optimization of tretment pathways in the clinical field of oral and maxillofacial surgery (OMS). As a result a proposal is being developed which converts 7 elective medical pattern and the heterogeneous processstructures in a standardized treatment pathway OMS. Based on the derivation of standardized treatment pathways and the definition of so-called "Standard Operating Procedures" (SOPs) a modular system for medical treatment is provided which guarantees a configurable individualization of the treatmet process for the patient. Based on the detailed analysis and derivation of target structures for clinical pathways on the example of OMS at the University Medical Center Dresden and their linkage to interdisciplinarities under the procedural aspect this bachelor graduation paper-work makes a contribution to process optimization in the hospital and at the same time forms a contribution to the modeling of a model-aided, evidence-based process management.
27

Využití židovské hudby v hodinách hudební výchovy / The Use of Jewish Songs in Music Classes

Filipová, Eva January 2018 (has links)
Czech school's curriculum often omits Jewish music. Based on the proposal of concrete music classes, this thesis aims at evolving and enriching this topic. The thesis is divided into two parts. Theoretical part (chapters one and two) begins with description of Jewish culture, history, religion, habits and holidays, including Jewish languages and specifics between Ashkenazi and Sephardic Jews, and follows with description of Jewish music, comprising particular modes and religious and secular music. The objective of this part is to present necessary broader information about Jewish culture for proposed concrete classes. Practical part (third chapter) proposes five thematically divided music classes based on three-phase model. Each music class includes staves extracts and texts; sheet music is annexed. The objective of music classes, which are based on music activities and methods of critical thinking and emphasise creativity of students and cooperation among them, is to build key competences and evolve multicultural behaviour. Nonetheless, this thesis is not a dogmatic proposal of plan of music classes, but primary serves as a source of inspiration for use and further development of concrete musical activities at school. KEY WORDS Jewish culture, Jewish music, music education, three-phase model,...
28

Análise da aplicação do modelo de fase constante na avaliação da mecânica respiratória em animais durante broncoconstrição. / Analysis of application of constant phase model in the evaluation of respiratory mechanics in animals during bronconconstrição.

Renato de Lima Vitorasso 20 June 2016 (has links)
A avaliação da mecânica respiratória é realizada comumente por meio de modelagem matemática. Um modelo amplamente utilizado é o de fase constante que se ajusta à impedância respiratória. Uma das variáveis exibidas por equipamentos de ventilação que aplicam o modelo citado é o Coeficiente de Determinação (COD), um medidor do ajuste do modelo. Há algumas situações em que o COD pode apresentar-se baixo, como: sedação superficial, respiração espontânea, perturbações externas e não linearidade. Entretanto, apesar de os valores de COD estarem disponíveis em ventiladores que utilizam os modelos de fase constante, a literatura é escassa em trabalhos que o citem. O objetivo deste trabalho foi analisar o comportamento do COD em uma curva dose resposta de camundongos BALB/c divididos em um grupo controle e um grupo com modelo animal de asma (OVA) e propor uma alternativa caso o modelo de fase constate não possa ser aplicado. Foram encontrados piores ajustes nas doses mais altas, principalmente no grupo OVA. Foi encontrada uma associação entre parâmetros excluídos nas 5 primeiras medidas e doses (p=0,0026) no grupo OVA. Foram excluídas 11 mensurações na última dose enquanto na primeira ou segunda doses apenas 2. O risco relativo para apresentar medidas excluídas entre a última e primeira ou segunda doses foi: 5,5 e IC: 1,30 - 23,26. A problemática de ter-se encontrado diferenças nestes momentos é que estas são as medidas relacionadas aos maiores valores de parâmetros de cada dose e tradicionalmente são os valores apresentados em estudos científicos. Os valores de pressão traqueal máxima média e mínima comportaram-se de maneira similar em termos de discriminação intergrupos, apresentando diferença (p<0,05) nas doses de 0,3 e 1 mg/kg, assim como o Rn . Em termos de substituição, é possível optar pelo uso de valores de pressão traqueal em detrimento aos parâmetros modelados em momentos em que o modelo de fase constante não deveria ser aplicado, a exemplo de valores baixos de COD em momentos de extrema broncoconstrição. A utilização dos valores de pressão traqueal é viável, por não serem obtidos por meio de uma modelagem matemática e sim por mensuração. Portanto, como os parâmetros Rn G e H são obtidos por meio de modelagem matemática e não por mensuração direta, o mau ajuste do modelo significa que os parâmetros modelados não podem ser aplicados na análise da situação em questão. Ademais, como alternativa é possível utilizar valores de pressão mensurados como variável de resposta, ainda que estes não discriminem vias aéreas e parênquima. / Assessment of respiratory mechanics is commonly performed through the application of mathematical models. A widely applied model is the constant phase model, which fits the respiratory impedance. One of the variables presented by ventilators that apply this model is the Coefficient of Determination (COD), it is used to assess the goodness of fit of the model. There are situation where the COD value is low, such as: superficial sedation, spontaneous breathing, external disturbances and nonlinearity. However, despite the COD value are available for ventilators that apply the constant phase model, the literature is still scarce in studies that mention this coefficient. The aim of this study was to analyze the COD behavior in dose response curves of BALB/c mice divided into a control group and animal model of asthma (OVA) and offer an alternative for moments that the constant phase model should not be applied. It was found an association between parameters excluded in the first five measures and doses (p = 0.0026) in the OVA. Eleven measurements were excluded at the last dose while in the first or in the second doses, only two. The relative risk to present excluded measures between the last and first or second doses was 5.5 and CI: 1.30 to 23.26. The problem about the differences found in these moments is that these are the measures associated to higher model parameter\'s values for each dose and traditionally are the values shown in scientific studies. The minimum, mean and maximal values of tracheal pressure behaved similarly on a inter group matter, presenting differences (p<0,05) at these doses: 0.3 and 1 mg/kg. The same pattern was observed for Rn . It is possible to use values of tracheal pressure instead of modeled parameters in moments that the constant phase model should not be applied, like low COD in moments of severe bronchoconstriction. This replacement of parameters through tracheal pressure is possible because tracheal pressure is not obtained via mathematical models but through mensuration. Therefore, as the Rn G e H parameters are obtained through mathematical modeling and not via direct mensuration, the poor adjustment means that these parameters should not be applied on the moments presented on this study. In addition, as an alternative it is possible to use pressure values measured as a variable of response, even if the pressure values are not able to distinguish between airway and parenchyma.
29

Impedância respiratória de entrada: comparação entre os métodos convencional e de wavetube. / Input respiratory impedance: comparison between conventional and wavetube methods.

Vitor Mori 26 August 2015 (has links)
A impedância respiratória de entrada pode ser obtida pela Técnica das Oscilações Forçadas (FOT) através de dois métodos diferentes: convencional e de wavetube. Nessa dissertação, primeiramente realizamos uma revisão bibliográfica com enfoque nos assuntos de interesse para esse trabalho, como definições e modelagem de impedância, descrições e bases teóricas para a realização dos dois métodos e descrição dos equipamentos utilizados por cada um dos métodos. A partir de dados experimentais da impedância, em camundongos machos do tipo BALB/c normais, obtidos em dois equipamentos diferentes fez-se uma comparação utilizando como base o Modelo de Fase Constante, analisando possíveis divergências e buscando compreender os motivos de eventuais discrepâncias. Um dos equipamentos (flexiVent, SCIREQ, Canadá) emprega o método convencional enquanto o outro equipamento foi desenvolvido pelo grupo do professor Zoltán Hantos, da Universidade de Szeged, Hungria, e se utiliza do método de wavetube. Tal trabalho foi motivado pela ausência de referências bibliográficas que comparam os dois métodos. A análise dos resultados experimentais nos sugere que os parâmetros obtidos para o Modelo de Fase Constante nos dois equipamentos são diferentes e não comparáveis. / The input respiratory impedance can be obtained by two different methods of performing the Forced Oscillations Technique (FOT): conventional and wavetube method. In this dissertation, first we made a literature review focusing on issues of interest to this work, as definitions and models of impedance, description and theoretical basis for the realization of the two methods and description of the equipments used by each method. Using experimental data of impedance in BALB/c male mice, from two different equipments a comparison was made based on the Constant Phase Model, analyzing possible differences between them and trying to understand the reasons for any discrepancies. The first equipment (flexiVent, SCIREQ, Canada) uses the conventional method while the second one, developed by the research group of Professor Zoltán Hantos of the University of Szeged, Hungary, uses the wavetube method. This work was motivated by the lack of literature references comparing the model parameters obtained by both methods. The analysis of experimental results suggests that the equipments are different and not comparable.
30

Práce s historickou literaturou v primě a sekundě víceletého gymnázia / Historical literature in the first and second classes of grammar school

Špoková, Markéta January 2015 (has links)
Main goal of this thesis is to test efectivity of teaching grammar school literature based on one book only. Secundary goal is to make teaching of historical literature for grammar's school first and second year students more attractive. This thesis is based on five worksheets, every one of them is designed for different literary aim. All of them are based on book "Můj Golem" wrote by Marek Toman. Lectures are governed by three-phase model of teaching which combines different methods for work with pupils. This thesis proofs that, use of one book in long-term tuition with different attitude, combined with appropriate goals and attractive methods, is one way to teach literature. Also this thestis helps making rather unpopular subject of historical literature more attractive to students.

Page generated in 0.0618 seconds