• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 19
  • 1
  • Tagged with
  • 20
  • 20
  • 20
  • 16
  • 12
  • 8
  • 8
  • 8
  • 7
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Utilização do ácido ascórbico como tentativa de reverter o efeito da desproteinização com hipoclorito de sódio na dentina radicular, utilizando diferentes sistemas de cimentação / Redox potencial of ascorbic acid after sodium hypochlorite deproteinization to root dentine with different adhesive systems

Leonardo Fernandes da Cunha 06 April 2009 (has links)
O objetivo deste trabalho foi avaliar o efeito da aplicação de ácido ascórbico após a desproteinização da dentina radicular, utilizando um cimento auto-adesivo e comparando-o a outros dois sistemas adesivos. Possíveis diferenças de união adesiva entre os terços radiculares também foram avaliadas. Quarenta e cinco raízes de incisivos bovinos foram divididas em três grupos, conforme o tratamento da raiz: irrigação com soro fisiológico; desproteinização com NaOCl (5%) por 10 minutos; irrigação com NaOCl por 10 min seguida da aplicação de ácido ascórbico por 10 min. O cimento autoadesivo Rely X U100 foi utilizado para cada um dos grupos citados. O cimento Rely X ARC foi utilizado com outros dois adesivos, para efeito de comparação: Single Bond e Clearfil SE Bond. Os espécimes foram armazenados em água destilada por 24 horas e testados quanto à resistência à extrusão (push-out). Os resultados foram submetidos ao teste ANOVA a três critérios e Dunnet T3 (=0.05). Não foram encontradas diferenças estatisticas entre os materiais utilizados. A desproteinização resultou em resistência adesiva diminuída, enquanto o tratamento subsequente com ácido ascórbico foi capaz de devolver a resistência adesiva em valores semelhantes aos do grupo controle. Diferenças entre os terços radiculares foram encontradas na seguinte sequência: coronal>médio>apical. O cimento auto-adesivo utilizado se comportou da mesma forma que os demais sistemas adesivos. O ácido ascórbico foi capaz de reverter o efeito de oxidação causado pela desproteinização. / The aim of this study was to evaluate the effect of ascorbic acid after root dentin treatment with sodium hypochlorite. A self-adhesive cement was compared with other two adhesive systems. The bond strength was also evaluated at different depths (coronal, middle, apical). Forty five single-rooted standard bovine teeth were divided in three groups. Specimens in each group were treated as follows: irrigation with physiologic serum; with NaOCl (5%) for 10 min; with NaOCl for 10 min and ascorbic acid for 10 min. The self-adhesive cement Rely X U100 was used for each one of the mentioned groups. The cement Rely X ARC was used with other two adhesives (Single Bond and Clearfil SE Bond). Specimens were stored in distilled water for 24 hours. Push-out tests were performed by using a universal testing machine, and the data was statistically analyzed (analysis of variance [ANOVA] and Dunnet T3; P < .05) A significant difference was not found among the materials tested. The deproteinization resulted in reduced bond strengths; though the subsequent treatment with ascorbic acid was capable to return the bond strengths. Differences among the region of post space were found: coronal>middle>apical. The ascorbic acid was capable to reverse the oxidation effect of the dentin deproteinization; the self-adhesive cement was similar to the other systems tested.
12

Influência do cimento resinoso e do cimento endodôntico sobre a resistência e durabilidade da união entre um pino de fibra de vidro e a dentina intra radicular: avaliação in vitro

Landa, Fabiano Vieira de 01 March 2013 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-05-13T13:13:15Z No. of bitstreams: 1 fabianovieiradelanda.pdf: 991924 bytes, checksum: 76f33860854c1fc8809b33683cbef6a6 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-06-27T20:33:37Z (GMT) No. of bitstreams: 1 fabianovieiradelanda.pdf: 991924 bytes, checksum: 76f33860854c1fc8809b33683cbef6a6 (MD5) / Made available in DSpace on 2016-06-27T20:33:37Z (GMT). No. of bitstreams: 1 fabianovieiradelanda.pdf: 991924 bytes, checksum: 76f33860854c1fc8809b33683cbef6a6 (MD5) Previous issue date: 2013-03-01 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo do presente estudo foi avaliar as seguintes hipóteses: Ho- não haveria influência do cimento resinoso e do cimento obturador do canal radicular sobre a durabilidade da união entre um pino de fibra de vidro e a dentina intra-radicular; H1- haveria a influência do tipo do cimento obturador sobre a durabilidade de união entre um pino de fibra de vidro e a dentina intra-radicular: H2-haveria a influência do tipo de cimento resinoso sobre a durabilidade de união entre um pino de fibra de vidro e a dentina intra-radicular e H3-haveria a influência da profundidade da cimentação sobre a durabilidade de união entre um pino de fibra de vidro e a dentina intra-radicular. Foram utilizados 40 caninos humanos, os quais foram divididos aleatoriamente em quatro grupos.R+E Relyx U100/ Endofill, P+E Panavia F2.0/EndoFill, R+S Relyx U100/Sealer 26, P+S Panavia F2.0/Sealer 26. Ao término dos procedimentos de cimentação, os corpos de prova foram seccionados em uma máquina de corte de precisão (Lab Cut Isomet 1000 Precision Saw) em 4 fatias de 2mm referente as diferentes profundidades: Apical, Médio Apical, Médio Coronal, Coronal. Em seguida, as fatias foram submetidas a ensaios mecânicos de extrusão Push-out em uma máquina de ensaios mecânicos EMICcom célula de carga de 50N, a velocidade de 0,5mm/min.Os resultados obtidos de acordo com as diferentes profundidades de cimentação analisados foram os seguintes(p≥0,05) (Mpa),1 porção apical R+E (1,35±1,28), P+E (2,70±0,89), R+S (3,89±0,70), P+S (4,30±1,02), 2 porção médio apical R+E (1,38±1,28), P+E (2,98±1,43), R+S (4,02±1,14), P+S (4,49±1,82), 3 porção médio coronal R+E (2,46±0,73), P+E (3,72±0,78), R+S (4,85±0,71), P+S (6,14±0,73), 4 porção coronal R+E (5,59±1,08), P+E (5,74±1,06), R+S(6,71±1,07), P+S (7,40±1,51).Os resultados obtidos confirmam as três hipóteses testadas: h1,h2 e h3. / This work has sought to evaluatethe following hypothesis: Ho-there would be no influence ofresin cementandroot canalsealeron the durabilityof the union betweenthe fiberglass postand the dentin, H1- would influencethetypesealeron the durabilityof the union between thefiber glass post andthedentin: H2-wouldinfluencethe type ofresin cementon the durabilityof the union betweenthe fiber glass post andthedentinandH3-would influencethe depth ofcementationon the durabilityof the union between the fiber glass post andthe dentin. Fortyhuman canines, were randomly dividedinto four groups. G1(R +E)RelyxU100/Endofill, G2(P +E)PanaviaF2.0/EndoFill, G3(R +S) RelyxU100/Sealer26,G4(P +S) PanaviaF2.0/Sealer26.At the endof thecementingprocedure, the specimenswere sectionedin aprecisioncutting machine(Isomet 1000PrecisionLabCutSaw) on 4slices of2mm. Thenthe sliceswere subjected tomechanical testsextrusionPush-out in amechanical testing machinewith a load cellEMIC50N, speed 0.5 mm/ min.The resultsaccording to different depthcementinganalyzedwere as follows: (p ≥ 0.05) (Mpa) 1apical R+E (1.35 ±1.28), P+E (2.70 ±0.89),R+S(3.89±0.70), P+S(4.30±1.02), 2 middleapicalR+E(1.38±1.28), P+E(2.98±1.43), R+S(4.02± 1.14), P+S(4.49±1.82), 3 mediumcoronalR+E(2.46±0.73), P+E(3.72±0.78), R+S(4,85 ±0.71), P+S(6.14±0.73), 4 coronalR+E(5.59±1.08), P+E(5.74±1.06), R+S(6.71±1.07), P+S (7.40 ±1.51). The results also confirmedthe threehypothesis tested: h1, h2andh3.
13

Comparação entre cimentos resinosos e uma resina \"bulk fill\" na cimentação de pinos de fibra de vidro - Análise de resistência adesiva e dureza / Comparison between resin cements and a \"bulk fill\" resin composite on the luting of fiberglass- reinforced posts cementation - Bond strength and hardness analysis

Lobo, Tamile Rocha da Silva 29 January 2018 (has links)
Este estudo comparou a performance de quarto agentes cimentantes com diferentes estratégias adesivas para cimentação de pinos de fibra de vidro em canais radiculares, através do teste de resistência adesiva e avaliando a dureza em diferentes profundidades. Para isto, foram utilizadas 60 raízes bovinas tratadas endodonticamente. Foram cimentados pinos de fibra de vidro Rebilda Post 20 de acordo com os seguintes protocolos divididos nos seguintes grupos: Grupos QM: Adesivo autocondicionante dual Futurabond DC + cimento resinoso dual Bifix QM; Group SE: Cimento resinoso autocondicionante de polimerização dual Bifix SE; Group RB: Adesivo autocondicionante de polimerização dual Futurabond DC + Resina Rebilda; Group XB: aplicação do adesivo autocondicionante de polimerização dual Futurabond DC + resina composta do tipo \"bulk fill\" X-tra Base. As raízes foram cortadas em fatias de 1mm e separadas em terços, sendo obtidos 2 corpos de prova por terço. Foram avaliadas a resistência adesiva (n=10) e a microdureza (n=5), após uma semana e após 4 meses de armazenamento em água. Para o teste de resistência adesiva (push- out) uma fatia de cada terço foi testada depois de uma semana e as outras 3 fatias provenientes do mesmo dente avaliadas após 4 meses. O ensaio de push out foi realizado a uma velocidade de 0,5mm/min até o deslocamento do pino e/ou fratura da interface adesiva. Para o teste de microdureza 20 dentes foram selecionados aleatoriamente e de cada dente foram obtidas seis 6 fatias que foram armazenadas em água destilada por uma semana até a mensuração em microdurômetro, após uma semana e após 4 meses. Os corpos de prova foram submetidos ao teste de microdureza Knoop em microdurômetro HMV-2000 (Shimadzu, Tokyo, Japan), cinco endentações foram realizadas na camada de cimento de cada fatia. Os dados referentes aos testes de resistência adesiva (push- out) e microdureza foram submetidas análise de variância 3 fatores (ANOVA), teste de tukey (p<0,05) e teste de correlação de Person. Os valores de resistência adesiva não apresentaram diferenças estatísticas significantes quando observado os valores de resistência adesiva entre os grupos QM, RB e XB (p>=0.05), porém menores valores de resistência adesiva foram observados no Grupo SE. Quando considerada a variável envelhecimento não foram encontradas diferenças na resistência adesiva medida em uma semana e 4 meses (p>=0.05). Para a microdureza diferenças estatisticamente significantes foram encontradas nos diferentes terços da raiz (p<0.05). Os agentes cimentantes apresentaram diferenças estatísticas significantes na dureza (p<0.05). O grupo XB apresentou os maiores valores seguido por QM, RB e SE. Os grupos SE, RB e XB não apresentaram 80% da dureza máxima nas fatias correspondentes a região apical do canal radicular. O teste de Person mostrou haver correlação positiva linear entre a resistência adesiva e a dureza medidas antes e após o envelhecimento. O uso cimento resinoso dual, associado a uma aplicação anterior do sistema adesivo, ainda é a escolha mais segura, pois apresentou valores de força de adesão elevados, associados a valores de dureza adequados, mesmo em regiões apicais do canal radicular. / This study compared the performance of four cementitious agents with different adhesive strategies for cementing fiberglass pins in root canals, through the adhesive strength test and evaluating the hardness at different depths. For this, 60 endodontically treated bovine roots were used. Rebilda Post 20 fiberglass pins were cemented according to the following protocols divided into the following groups: QM groups: dual self-etching adhesive Futurabond DC + resin cement Bifix QM; Group SE: Dual polymerization resin cement Bifix SE; Group RB: application of self-etching dual-polymerization adhesive Futurabond DC + resin Rebilda; Group XB: application of the self-etching adhesive for dual polymerization Futurabond DC + composite resin of the bulk fill type X-tra Base. The roots were cut into 1mm slices and separated into thirds, obtaining 2 specimens per third. Bond strength (n =10) and microhardness (n = 5) were evaluated after one week and after 4 months of storage in water. For the push-out test one slice of each third was tested after one week and the other 3 slices from the same tooth evaluated after 4 months. The push out test was performed at a speed of 0.5mm / min until the pin displacement and / or fracture of the adhesive interface. For the microtensile test, 20 teeth were randomly selected and six slices were obtained from each tooth, which were stored in distilled water for one week until microdurometer measurement, after one week and after four months. The specimens were submitted to the Knoop microhardness test in HMV-2000 microdurometer (Shimadzu, Tokyo, Japan), five indentations were performed in the cement layer of each slice. The data for the tests of bond strenght (push-out) and microhardness were submitted to analysis of variance 3 factors (ANOVA) and Tukey test (p <0.05) and Person correlation test. The bond strength values did not present significant statistical differences when the adhesive strength values were observed between the groups QM, RB and XB (p>=0.05), but lower values of adhesive strength were observed in the SE Group. When the aging variable was considered, differences in adhesive strength measured at one week and 4 months (p>=0.05) were not found. For microhardness, statistically significant differences were found in the different thirds of the root (p <0.05). The cementing agents presented significant statistical differences in the hardness (p <0.05). The XB group presented the highest values followed by QM, RB and SE. The groups SE, RB and XB did not present 80% of the maximum hardness in the slices corresponding to the apical region of the root canal. The Person test showed a linear positive correlation between the adhesive strength and the hardness measured before and after aging. The use of dual resin cement, combined with a previous application of the adhesive system, is still the safest choice, since it presented high values of bond strength, associated with adequate hardness values, even in apical regions of the root canal.
14

EFEITO DA DENSIDADE DE ENERGIA DA LUZ NA ADESÃO ENTRE PINOS DE FIBRA E DENTINA RADICULAR / Effects of energy density of light-activation of adhesive systems on bonding fiber posts to root canals

Szesz, Anna Luiza 25 February 2014 (has links)
Made available in DSpace on 2017-07-24T19:22:35Z (GMT). No. of bitstreams: 1 ANNA LUIZA SZESZ.pdf: 3989892 bytes, checksum: 237bfbd8af89362f6139a3c445f884d8 (MD5) Previous issue date: 2014-02-25 / This study evaluated, the intensity of light transmitted through a translucent fiber post ( Whitepost DC n° 2) using an experimental system and the effect of different densities of light energy in adhesive properties: degree of conversion within the hybrid layer (DC), nanoleakage (NL) and bond strength (μTBS) of two adhesive systems to dentin (Ambar [AM] and Excite DSC [EX]). The roots of 72 human premolars were prepared endodontically and divided into groups (n=6) according to the combination of factors: adhesive system (AM and EX) and energy density (16, 48 and 288 J/cm²). After cementing fiber post the roots with fiber post were subjected to μTBS (push-out) (n = 7) in a universal testing machine (0.5 mm/min). DC analysis (%) in situ (n = 2) was made by micro -Raman spectroscopy and NL was evaluated by SEM after immersing the samples in 50% silver nitrate (n=3). Data from the μTBS, NL, and DC of each adhesive were analyzed by 3-way repeated measures ANOVA (adhesive vs. Energy density vs. root third) and Tukey test (α = 0.05) . To measure the intensity of light transmitted through the post, the measuring device consisted of a light beam pulsed laser focusing perpendicular to the bottom surface of the post, and in the direction parallel to the axis of the post detector capable of measuring the scattered light at the post. To simulate the variation of light intensity, filters were used in this system with optical density varying the light intensity of 100, 25 and 10%. The results of μTBS (MPa) showed a significant difference for the middle and apical (p <0.05) thirds when an increase in energy density from 16 to 48 and 288 J/cm²respectively. The DC (%) significantly increased the density of 288 J/cm² in the middle and apical thirds compared the same with the lower energy density of 16 J/cm² (p < 0.05). The NL (%) decreases significantly from the energy density of 48 J/cm² in the middle and apical (p thirds < 0.05) and remained constant for the density of 288 J/cm² (p > 0.05), in general, none of the tests results showed a significant difference when the cervical third was evaluated . Regarding the results of the intensity of light scattered by the post, light intensity reduced to 45,5% in the cervical region, to 14,2% and 5,3% in the middle and apical thirds, respectively. As for simulating the variation of light intensity, it was observed that the increase of the intensity of light incident on the base of the cervical post provides a gain of intensity of light reaching the apical level. / Este estudo avaliou, através de um sistema experimental, a intensidade de luz transmitida por um pino de fibra translúcido (Whitepost DC n°2) e o efeito de diferentes densidades de energia da luz nas propriedades adesivas: grau de conversão no interior da camada híbrida (GC), nanoinfiltração (NI) e resistência de união (RU) à dentina de dois sistemas adesivos (Ambar [AM] e Excite DSC [EX]). As raízes de 72 pré-molares humanos foram preparadas endodonticamente e divididas em grupos (n=6) de acordo com a combinação dos principais fatores: sistema adesivo (AM e EX), e densidade de energia (16, 48 e 288 J/cm²). Após cimentação dos pinos de fibra, foi testado a RU (push-out) (n=7) em uma máquina de ensaios universal (0,5 mm/min). A análise do GC (%) in situ (n=2) foi feita através da espectroscopia micro-Raman e a NI foi avaliada por MEV após a imersão das amostras em 50% em nitrato de prata (n=3). Os dados de RU, GC e NI de cada adesivo foram analisados por ANOVA de 3 fatores de medidas repetidas (adesivo vs. densidade de energia vs. terço radicular) e teste de Tukey (α = 0,05). Para mensuração da intensidade de luz transmitida pelo pino, o sistema era constituído por um feixe de luz laser pulsado incidindo perpendicularmente a superfície da base do pino, e na direção paralela ao eixo do pino um detector capaz de mensurar a luz espalhada no pino. Para simular a variação da intensidade de luz foram utilizados junto a esse sistema filtros de densidade óptica, variando a intensidade de luz em 100, 25 e 10%. Os resultados de RU (MPa) demonstraram diferença significativa para os terços médio e apical (p < 0,05) quando houve aumento da densidade de energia de 16 para 48 e 288 J/cm² respectivamente. O GC (%) aumentou significativamente na densidade de 288 J/cm² nos terços médio e apical quando comparado os mesmos terços com a menor densidade de energia 16 J/cm² (p <0,05). A NI (%) diminui significativamente a partir da densidade de energia de 48 J/cm² nos terços médio e apical (p < 0,05) e se manteve constante para a densidade de 288 J/cm² (p > 0,05). Em geral, nenhum dos testes apresentaram resultados com diferença significativa quando o terço cervical foi avaliado. Em relação aos resultados da intensidade da luz espalhada pelo pino observamos que na região cervical a intensidade de luz reduz para 45,5 % no terço médio para 14,2 % e para apical 5,3%. Quanto a simulação da variação da intensidade da luz, foi possível observar que o aumento da intensidade de luz incidente na base cervical do pino proporciona um ganho de intensidade de luz que chega ao nível apical.
15

EFEITO DO TIPO DE INSTRUMENTO E DA TÉCNICA OBTURADORA NA RESISTÊNCIA À FRATURA DE DENTES RESTAURADOS. / EFFECT OF THE INSTRUMENT TYPE AND ROOT CANAL FILLING TECHNIQUE ON FRACTURE RESISTANCE OF RESTORED ROOTS

Santini, Manuela Favarin 03 March 2012 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The aim of this study was to assess the effect of instrument type (K-files and nickel-titanium rotary files) and the root canal filling technique (active and passive lateral condensation) on fracture resistance. Sixty eight teeth (canines and premolars) were divided into 4 groups (n=17): G1 - hand instrumentation and active lateral condensation; G2 - hand instrumentation and passive lateral condensation; G3 - rotary instrumentation and active lateral condensation; G4 - rotary instrumentation and passive lateral condensation. Before the filling, the roots were embedded in acrylic resin to simulate the periodontal ligament using a polyether impression material. Every root was restored with glass fiber post and metallic crown. The specimens were mechanical cycled (500.000 cycles, 45°, 37° C, 133 N, 2 Hz) and they were submitted to fracture test (45º, 1 mm/ min) until the fracture occurred. The Kruskal-Wallis test showed that the groups were not different from each other (p = 0. 247). In situations where an endodontic post is required, the instrument type and the obturation technique seem to have no influence on fracture resistance. / O objetivo deste estudo foi avaliar o efeito do tipo de instrumento (limas manuais tipo K e instrumentos rotatórios de NiTi) e da técnica obturadora (condensação lateral ativa e condensação lateral passiva) na resistência à fratura. Para isso, 68 dentes (caninos e pré-molares) foram divididos em 4 grupos (n=17): G1 - instrumentação manual e condensação lateral ativa; G2 - instrumentação manual e condensação lateral passiva; G3 - instrumentação rotatória e condensação lateral ativa; G4 - instrumentação rotatória e condensação lateral passiva. Antes da etapa obturadora, as raízes foram embutidas em resina acrílica para a simulação do ligamento periodontal com material de moldagem à base de poliéter. Todas as raízes foram restauradas com pino de fibra de vidro e coroa metálica. Os espécimes foram submetidos à ciclagem mecânica (500.000 ciclos, 45°, 37° C, 133 N, 2 Hz) e ao teste de resistência à fratura (45º, 1 mm/ min) até a falha ocorrer. O teste de Kruskal-Wallis mostrou que os grupos não foram diferentes entre si (p = 0, 247). Em situações em que há a necessidade de cimentação de pino intrarradicular, a escolha do tipo de instrumento e da técnica obturadora parece não ter influência na resistência à fratura.
16

Comparação entre cimentos resinosos e uma resina \"bulk fill\" na cimentação de pinos de fibra de vidro - Análise de resistência adesiva e dureza / Comparison between resin cements and a \"bulk fill\" resin composite on the luting of fiberglass- reinforced posts cementation - Bond strength and hardness analysis

Tamile Rocha da Silva Lobo 29 January 2018 (has links)
Este estudo comparou a performance de quarto agentes cimentantes com diferentes estratégias adesivas para cimentação de pinos de fibra de vidro em canais radiculares, através do teste de resistência adesiva e avaliando a dureza em diferentes profundidades. Para isto, foram utilizadas 60 raízes bovinas tratadas endodonticamente. Foram cimentados pinos de fibra de vidro Rebilda Post 20 de acordo com os seguintes protocolos divididos nos seguintes grupos: Grupos QM: Adesivo autocondicionante dual Futurabond DC + cimento resinoso dual Bifix QM; Group SE: Cimento resinoso autocondicionante de polimerização dual Bifix SE; Group RB: Adesivo autocondicionante de polimerização dual Futurabond DC + Resina Rebilda; Group XB: aplicação do adesivo autocondicionante de polimerização dual Futurabond DC + resina composta do tipo \"bulk fill\" X-tra Base. As raízes foram cortadas em fatias de 1mm e separadas em terços, sendo obtidos 2 corpos de prova por terço. Foram avaliadas a resistência adesiva (n=10) e a microdureza (n=5), após uma semana e após 4 meses de armazenamento em água. Para o teste de resistência adesiva (push- out) uma fatia de cada terço foi testada depois de uma semana e as outras 3 fatias provenientes do mesmo dente avaliadas após 4 meses. O ensaio de push out foi realizado a uma velocidade de 0,5mm/min até o deslocamento do pino e/ou fratura da interface adesiva. Para o teste de microdureza 20 dentes foram selecionados aleatoriamente e de cada dente foram obtidas seis 6 fatias que foram armazenadas em água destilada por uma semana até a mensuração em microdurômetro, após uma semana e após 4 meses. Os corpos de prova foram submetidos ao teste de microdureza Knoop em microdurômetro HMV-2000 (Shimadzu, Tokyo, Japan), cinco endentações foram realizadas na camada de cimento de cada fatia. Os dados referentes aos testes de resistência adesiva (push- out) e microdureza foram submetidas análise de variância 3 fatores (ANOVA), teste de tukey (p<0,05) e teste de correlação de Person. Os valores de resistência adesiva não apresentaram diferenças estatísticas significantes quando observado os valores de resistência adesiva entre os grupos QM, RB e XB (p>=0.05), porém menores valores de resistência adesiva foram observados no Grupo SE. Quando considerada a variável envelhecimento não foram encontradas diferenças na resistência adesiva medida em uma semana e 4 meses (p>=0.05). Para a microdureza diferenças estatisticamente significantes foram encontradas nos diferentes terços da raiz (p<0.05). Os agentes cimentantes apresentaram diferenças estatísticas significantes na dureza (p<0.05). O grupo XB apresentou os maiores valores seguido por QM, RB e SE. Os grupos SE, RB e XB não apresentaram 80% da dureza máxima nas fatias correspondentes a região apical do canal radicular. O teste de Person mostrou haver correlação positiva linear entre a resistência adesiva e a dureza medidas antes e após o envelhecimento. O uso cimento resinoso dual, associado a uma aplicação anterior do sistema adesivo, ainda é a escolha mais segura, pois apresentou valores de força de adesão elevados, associados a valores de dureza adequados, mesmo em regiões apicais do canal radicular. / This study compared the performance of four cementitious agents with different adhesive strategies for cementing fiberglass pins in root canals, through the adhesive strength test and evaluating the hardness at different depths. For this, 60 endodontically treated bovine roots were used. Rebilda Post 20 fiberglass pins were cemented according to the following protocols divided into the following groups: QM groups: dual self-etching adhesive Futurabond DC + resin cement Bifix QM; Group SE: Dual polymerization resin cement Bifix SE; Group RB: application of self-etching dual-polymerization adhesive Futurabond DC + resin Rebilda; Group XB: application of the self-etching adhesive for dual polymerization Futurabond DC + composite resin of the bulk fill type X-tra Base. The roots were cut into 1mm slices and separated into thirds, obtaining 2 specimens per third. Bond strength (n =10) and microhardness (n = 5) were evaluated after one week and after 4 months of storage in water. For the push-out test one slice of each third was tested after one week and the other 3 slices from the same tooth evaluated after 4 months. The push out test was performed at a speed of 0.5mm / min until the pin displacement and / or fracture of the adhesive interface. For the microtensile test, 20 teeth were randomly selected and six slices were obtained from each tooth, which were stored in distilled water for one week until microdurometer measurement, after one week and after four months. The specimens were submitted to the Knoop microhardness test in HMV-2000 microdurometer (Shimadzu, Tokyo, Japan), five indentations were performed in the cement layer of each slice. The data for the tests of bond strenght (push-out) and microhardness were submitted to analysis of variance 3 factors (ANOVA) and Tukey test (p <0.05) and Person correlation test. The bond strength values did not present significant statistical differences when the adhesive strength values were observed between the groups QM, RB and XB (p>=0.05), but lower values of adhesive strength were observed in the SE Group. When the aging variable was considered, differences in adhesive strength measured at one week and 4 months (p>=0.05) were not found. For microhardness, statistically significant differences were found in the different thirds of the root (p <0.05). The cementing agents presented significant statistical differences in the hardness (p <0.05). The XB group presented the highest values followed by QM, RB and SE. The groups SE, RB and XB did not present 80% of the maximum hardness in the slices corresponding to the apical region of the root canal. The Person test showed a linear positive correlation between the adhesive strength and the hardness measured before and after aging. The use of dual resin cement, combined with a previous application of the adhesive system, is still the safest choice, since it presented high values of bond strength, associated with adequate hardness values, even in apical regions of the root canal.
17

Influência da terapia endodôntica e do envelhecimento artificial acelerado na resistência de união de pinos de fibra de vidro à dentina intrarradicular / Influence of endodontic therapy and artificial accelerated aging on fibreglass post bond strength to intraradicular dentine

Santana, Fernanda Ribeiro 28 May 2012 (has links)
Submitted by Luanna Matias (lua_matias@yahoo.com.br) on 2015-03-09T11:19:12Z No. of bitstreams: 2 Tese - Fernanda Ribeiro Santana - 2012.pdf: 12111889 bytes, checksum: 84cf2d3d0d514483cc202fde5fa79301 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luanna Matias (lua_matias@yahoo.com.br) on 2015-03-09T14:09:39Z (GMT) No. of bitstreams: 2 Tese - Fernanda Ribeiro Santana - 2012.pdf: 12111889 bytes, checksum: 84cf2d3d0d514483cc202fde5fa79301 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2015-03-09T14:09:39Z (GMT). No. of bitstreams: 2 Tese - Fernanda Ribeiro Santana - 2012.pdf: 12111889 bytes, checksum: 84cf2d3d0d514483cc202fde5fa79301 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2012-05-28 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Aim: To evaluate in vitro the influence of root canal instrumentation techniques, endodontic irrigants, endodontic sealers and artificial accelerated aging on fibreglass post bond strength to bovine intraradicular dentine. Methodology: Part 1. 120 bovine incisors were divided into 12 experimental groups (n=10) resulting from the interaction among 3 study factors: root canal instrumentation technique (RCPSS- root canal preparation with stainless steel instruments - KFile; RCPNiTi- root canal preparation with K3 Nickel-Titanium instruments), endodontic irrigant (NaOCl- 1% sodium hypochlorite; CHX- 2% chlorhexidine; O3- 1.2% ozonated water) (in all samples 17% EDTA was used to remove the smear layer) and specimens artificial accelerated aging (Immediate, test with no aging; Mediate, test performed after 2 months of water storage at 37°C). After root canal preparation, endodontic filling was not performed. Fibreglass posts were cemented with self-adhesive resin cement (RelyX U100, 3M-ESPE) and roots were cross-sectioned to obtain two slices of each third. Samples were submitted to micropush-out test and bond strength values (MPa) were analyzed by ANOVA in a split-plot arrangement and Tukey’s test (α = 0.05). Failure modes were evaluated under a confocal microscope. Part 2. 60 bovine incisors were divided into 6 experimental groups (n=10) resulting from the interaction between 2 study factors: endodontic sealer (Sx- Sealapex; S26- Sealer 26; AHAH Plus) and specimens artificial accelerated aging (Immediate, test with no aging; Mediate, test performed after 2 months of water storage at 37°C). Two control groups were employed (without root canal filling), represented by groups RCPNiTiNaOCl immediate and RCPNiTiNaOCl mediate of part 1 of the present study. In the six experimental groups, root canals were prepared 1mm from the apex with K3 Nickel-Titanium instruments associated with 1% sodium hypochlorite irrigation and 17% EDTA. They were then filled with gutta-percha and the specific sealer of each group, using the lateral compaction technique. Fibreglass posts were cemented with self-adhesive resin cement (RelyX U100, 3M-ESPE) and roots were cross-sectioned to obtain two slices of each third. Abstract xx Samples were submitted to micropush-out test and bond strength values (MPa) were submitted to ANOVA in a split-plot arrangement and Tukey’s test (α = 0,05). Comparisons with control groups were made using Dunnet test (α = 0.05). Failure modes were evaluated under a confocal microscope. Results: Part 1. In specimens submitted to water artificial aging, RCPNiTi presented higher bond strength values than RCPSS in apical third irrigated with NaOCl or CHX. Irrigation with NaOCl resulted in higher bond strength than O3. Artificial aging resulted in significant bond strength increase, except for middle and apical thirds of RCPSSO3 and apical of RCPNiTiO3. Bond strength significantly reduced in apical third. The prevalence of adhesive cement-dentine failure was verified in all groups. Part 2. Endodontic sealers showed no significant differences among them, however they presented significantly lower bond strength values than control groups (without filling), except in cervical third of groups tested immediately. Artificial aging did not interfere on bond strength to intraradicular dentine. There was a significant decrease on bond strength from cervical to apical third. The prevalence of adhesive cement-dentine failure was verified in all groups. Conclusions: Part 1. Root canal preparation with NiTi instruments associated with NaOCl irrigation and EDTA increased the bond strength of fiberglass posts cemented with self-adhesive resin cement to intraradicular dentine. Part 2. Endodontic sealers interfered negatively on bonding of fibreglass posts cemented with self-adhesive resin cement to intraradicular dentine. / Objetivo: Analisar in vitro a influência das técnicas de instrumentação do canal radicular, dos irrigantes e cimentos endodônticos e do envelhecimento artificial acelerado na resistência de união do pino de fibra de vidro à dentina intrarradicular em dentes bovinos. Metodologia: Parte 1. Cento e vinte incisivos bovinos foram divididos em doze grupos experimentais (n=10) resultantes da interação entre três fatores em estudo: técnica de instrumentação do canal radicular (PAI – preparo do canal radicular com instrumentos de aço inoxidável - K-File; PNiTi – preparo do canal radicular com instrumentos de Níquel-Titânio - K3); irrigante endodôntico (NaOCl- hipoclorito de sódio 1%; CHX- clorexidina 2%; O3- água ozonificada 1,2%) (em todas as amostras o EDTA 17% foi utilizado para a remoção de smear layer) e envelhecimento artificial acelerado dos espécimes (Imediato, teste sem envelhecimento; Mediato, teste após 2 meses de envelhecimento em água a 37°C). Após o preparo dos canais radiculares não foi realizada a obturação endodôntica. Pinos de fibra de vidro foram cimentados com cimento resinoso auto-adesivo (RelyX U100, 3M-ESPE) e as raízes foram seccionadas para obtenção de duas fatias de cada terço. As amostras foram submetidas ao teste de micropush-out e os dados de resistência de união (MPa) foram analisados por ANOVA com parcela subdividida e teste de Tukey (α = 0,05). Os padrões de falha foram avaliados por meio de microscopia confocal. Parte 2. Sessenta incisivos bovinos foram divididos em seis grupos experimentais (n=10) resultantes da interação entre dois fatores em estudo: cimento endodôntico (SX- Sealapex; S26- Sealer 26; AH- AH Plus) e envelhecimento artificial acelerado dos espécimes (Imediato, teste sem envelhecimento; Mediato, teste após 2 meses de envelhecimento em água a 37°C). Foram empregados dois grupos controles (sem obturação do canal radicular) representados pelos grupos PNiTiNaOCl imediato e PNiTiNaOCl mediato da parte 1 do presente estudo. Nos seis grupos experimentais os canais radiculares foram preparados 1mm aquém do ápice com instrumentos de Níquel-Titânio - K3 associado a Resumo xviii irrigação com NaOCl 1% e EDTA 17%. Em seguida, foram obturados com gutapercha e o cimento endodôntico específico de cada grupo, usando a técnica de condensação lateral. Pinos de fibra de vidro foram cimentados com cimento resinoso auto-adesivo (RelyX U100, 3M-ESPE) e as raízes foram seccionadas para obtenção de duas fatias de cada terço. As amostras foram submetidas ao teste de micropush-out e os dados de resistência de união (MPa) foram analisados por ANOVA com parcela subdividida e teste de Tukey (α = 0,05). Comparações com os grupos controles foram feitas pelo teste de Dunnet (α =0,05). Os padrões de falha foram avaliados por meio de microscopia confocal. Resultados: Parte 1. Nos espécimes submetidos ao envelhecimento artificial em água, PNiTi apresentou maiores valores de resistência de união que PAI no terço apical irrigado com NaOCL ou CHX. A irrigação com NaOCL resultou em maior resistência de união comparada a O3. O envelhecimento artificial resultou em aumento significante da resistência de união, exceto para os terços médio e apical de PAIO3 e apical de PNiTiO3. A resistência de união reduziu significativamente no terço apical. A prevalência de falha adesiva cimentodentina foi verificada em todos os grupos. Parte 2. Os cimentos endodônticos não mostraram diferenças significantes entre si, entretanto apresentaram valores de resistência de união significativamente menores que os grupos controles (sem obturação), exceto no terço cervical dos grupos testados imediatamente. O envelhecimento artificial não interferiu na resistência de união à dentina intrarradicular. Houve uma diminuição significante na resistência de união do terço cervical para o apical. A prevalência de falha adesiva cimentodentina foi verificada em todos os grupos. Conclusões: Parte 1. O preparo do canal radicular com instrumentos de NiTi associado a irrigação com NaOCl e uso do EDTA aumentou a resistência de união de pinos de fibra de vidro cimentados com cimento auto-adesivo à dentina intrarradicular. Parte 2. Os cimentos endodônticos interferiram negativamente na união de pinos de fibra de vidro cimentados com cimento auto-adesivo à dentina intrarradicular.
18

Efeito do número de pinos de fibra de vidro na resistência à fratura, deformação estrutural e distribuição de tensão em molares tratados endodonticamente

Barcelos, Luciana Mendes 12 February 2016 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / The aim of this study was to evaluate the biomechanical effect of the presence and number of fibreglass post in endodontically treated molars restored with composite resin. 45 human molars were selected, included in polystyrene resin cylinders with simulation of the periodontal ligament and endodontically treated. These teeth were randomized into three groups (n = 15): Wfgp, without fibreglass post and restored with Filtek Z350 XT; 1fgp, 1 fiberglass post Exact #2 cemented in the distal root with RelyX U200 and restored with Z350XT; and 2fgp, 2 fiberglass posts cemented with RelyX U200, one in the distal root and the other in the mesiobuccal root, restored with Z350XT. The specimens were submitted to mechanical fatigue with axial load of 50N. The tooth remaining deformation was measured using extensometers (n = 10) during occlusal loading of 100N and then until fracture. The other teeth (n = 5) were used to calculate the modulus of elasticity (GPa) and Vickers hardness (VH, N/mm2) of the enamel, dentin composite resin and fiberglass post in two positions: parallelly and transversally to the long axis of the post. The stress distribution was analyzed using three dimensional finite elements model, generated from micro-CT image of an intact tooth with its geometry similar of those used in the in vitro study. The calculated mechanical properties were used to characterize models of finite element analysis. The data of deformation and fracture resistance were tested for normality (Shapiro-Wilk) and equivalence of variances (test Levene), followed by parametric statistical tests appropriated for each test. One way Anova was performed for the axial compressive strength values, tooth remaining deformation and fracture resistance. Multiple comparisons were performed using Tukey test. The mean fracture data were submitted to the Chi-square test. Factorial analysis of variance on two factors was carried out considering as factors in study: the tooth surface deformation (B and L) and rehabilitation technique. All tests done had significance level &#945; = 0.05 and all analyses were performed with the statistical program Sigma Plot version 13.1 (Systat Software, San Jose, CA, USA). The use of two fiber glass posts resulted in lower fracture resistance than the groups without fiber glass - 22 - post and with one fiber glass post. During occlusal loading of 100N lingual surface of the remaining tooth showed higher deformation for all groups. The absence of fiber glass post resulted in significantly higher values of stress in the root and more irreparable fracture modes than the other groups. The use of a fiber glass post resulted in better ratio deformation/fracture resistance. The concentration of stress in the furcation area was slightly reduced with use of fiber glass post. It is concluded that the use of one fiber glass post to rehabilitated molars with direct composite resin showed higher resistance to fracture than the use of two fiberglass posts, lower tooth remaining deformation, better stress distribution and failure pat more repairable when compared to molars restored without use of fiber-glass post / O objetivo deste trabalho foi avaliar o efeito biomecânico da presença e do número de pinos de fibra de vidro em molares tratados endodonticamente e restaurados de forma direta com resina composta. Quarenta e cinco molares humanos foram selecionados, incluídos em cilindros de resina de poliestireno com simulação do ligamento periodontal e tratados endodonticamente. Estes dentes foram randomizados em três grupos (n=15): Spfv, sem pino de fibra de vidro, restaurado com Filtek Z350XT; 1pfv, 1 pino de fibra de vidro Exacto Nº 2 cimentado no canal distal com RelyX U200 restaurado com Z350XT; e 2pfv, 2 pinos de fibra de vidro Exacto Nº 2 cimentados com RelyX U200, um no canal distal e o outro no mesio-vestibular restaurado com Z350XT. As amostras foram submetidas à fadiga mecânica com carregamento axial de 50N. A deformação do remanescente foi mensurada usando extensômetros (n=10) durante o carregamento oclusal de 100N e em seguida até o momento de fratura. Os demais dentes (n=5) foram usados para calcular o módulo de elasticidade (E, GPa) e dureza Vickers (VH, N/mm2) do esmalte, dentina, resina composta e pino de fibra de vidro em duas posições: paralelamente e transversalmente ao longo eixo do pino. A distribuição de tensões foi analisada usando modelo tridimensional de elementos finitos gerado a partir de imagem de micro-CT de um dente hígido com medidas e geometrias representativo das amostras usadas na etapa experimental. Às propriedades mecânicas calculadas foram utilizadas para caracterizar os modelos da análise por elementos finitos. Os dados de deformação e resistência à fratura foram submetidos à teste de normalidade (Shapiro-Wilk) e equivalência de variâncias (teste de Levene), seguido por testes estatísticos paramétricos adequados para cada tipo de ensaio. Análise de variância em fator único foi realizada para os valores de resistência à compressão axial, deformação do remanescente e resistência à fratura. Comparações múltiplas foram realizadas usando teste de Tukey. Os dados de padrão de fratura foram submetidos ao teste Quiquadrado. Análise de variância fatorial em dois fatores foi realizada considerando como fatores em estudo: deformação da superfície do remanescente (V e L) e a técnica de reabilitação. Todos os testes empregados - 19 - tiveram nível de significância &#945;=0,05 e todas as análises foram realizadas com o programa estatístico Sigma Plot versão 13.1 (Systat Software Ins, San Jose, CA, USA). O uso de dois pinos de fibra de vidro resultou em menor resistência à fratura que os grupos sem pino de fibra de vidro e com um pino de fibra de vidro. Durante o carregamento oclusal de 100N a superfície lingual do remanescente demonstrou maior deformação para todos os grupos. A ausência de pino de fibra de vidro resultou em valores significativamente mais elevados de tensões na dentina radicular e modos de fratura irreparáveis significativamente maiores que os outros grupos. O uso de um pino de fibra de vidro resultou em melhor razão deformação/resistência fratura. A concentração de tensão na área de furca foi ligeiramente reduzida com uso de pino de fibra de vidro. Conclui-se que o uso de um pino de fibra de vidro para reabilitar molares inferiores com resina composta direta mostrou maior resistência à fratura que o uso de dois pinos de fibra de vidro, menor deformação do remanescente, melhor distribuição de tensões e padrão de falha com maior número de fraturas reparáveis quando comparado a molares restaurados sem uso de pino de fibra de vidro / Mestre em Odontologia
19

Restauração de dentes tratados endodonticamente: ensaio clínico randomizado e revisão sistemática com metánalise / Restoration of endodontically treated teeth: a randomized clinical trial and a systematic review with meta-analysis

Onofre, Rafael Sarkis 13 December 2012 (has links)
Made available in DSpace on 2014-08-20T14:30:09Z (GMT). No. of bitstreams: 1 Dissertacao_rafael_sarkis_onofre.pdf: 1491340 bytes, checksum: 00453dc2916d638be0bec47f9d29aa11 (MD5) Previous issue date: 2012-12-13 / The best way to restore endodontically treated teeth has been discussed in the literature because some factors can influence the post selection and the final restoration. Two of the most used intra-radicular posts are cast metal posts and glass fiber posts. Moreover, there is a large variability of in vitro studies that evaluate the use of different resin cement and the alterations of technique and the influence in the bond strength of glass fiber posts. The aims of the study were to compare the survival of two types of dental posts used to restore endodontically treated teeth with great damage of coronal walls and verify through a systematic review if there is difference on bond strength of glass fiber posts to dentin between self-adhesive and regular resin cements. Systematic review: In vitro studies that investigated the bond strength of glass fiber post luted with self-adhesive (RC) and regular (RC) were selected. Global comparison between self-adhesive (RC) and regular resin cement was performed. Two subgroup analyses were performed: self-adhesive resin cement x regular resin cement (etch-and-rinse adhesive), self-adhesive resin cement x regular resin cement (self-etch adhesive). The three analyses performed showed favorable results to self-adhesive resin cement. Clinical trial: The teeth were randomly allocated into two groups depending on the post used: glass fiber or cast metal post. Fifty-four (45 women) patients and 72 teeth were evaluated up to 3 years and the survival probabilities were 97.1% and 91.9% to cast metal posts and glass fiber posts. Four failures were observed, 2 glass fiber posts debonding (premolar and anterior tooth), 1 glass fiber post debonding associate with root fracture and 1 root fracture with a cast metal post. We can conclude that in vitro literature seems to suggest that the use of self-adhesive cement could help to achieve higher bond strength of GFPs to the root canal and after 3 years of follow up, both posts presented the same clinical performance and / A melhor maneira de se restaurar dentes tratados endodonticamente vem sendo muito discutida na literatura principalmente porque alguns fatores como a escolha do pino a ser utilizado pode influenciar o resultado final da restauração. Dois dos retentores intra-radiculares mais utilizados atualmente são os núcleos metálicos fundidos e os pinos de fibra de vidro. Além disso, existe uma grande variabilidade de estudos in vitro que avaliam tanto a utilização de diferentes cimentos resinosos como alterações das técnicas e a influência na resistência de união de pinos de fibra de vidro. O objetivo deste trabalho foi avaliar as taxas de sucesso clínico de dentes tratados endodonticamente sem remanescente coronário e restaurados com de pino de fibra de vidro ou núcleo metálico fundido através de um ensaio clínico randomizado. Além disso, realizar uma revisão sistemática da literatura de ensaios in vitro que comparassem a resistência de união de pinos de fibra de vidro cimentados com cimento resinoso regular e cimento resinoso autoadesivo. Para a revisão sistemática, estudos in vitro que avaliaram a resistência de união de pinos de fibra de vidro cimentados com cimento autoadesivo e cimento regular foram selecionados. As seguintes metánalises foram realizadas: comparação global entre cimento autoadesivo x cimento regular e análises de subgrupo cimento autoadesivo x cimento regular (adesivo etch-and-rinse) e cimento autoadesivo x cimento regular (adesivo self-etch). As três análises mostraram resultados estatisticamente significantes e favorecendo o uso de cimento autoadesivo. No ensaio clínico, os dentes selecionados foram randomizados e alocados em 2 grupos dependendo do pino utilizado. Após 3 anos, 54 pacientes (72 dentes: 35 núcleos metálicos fundidos e 37 pinos de fibra de vidro) foram avaliados. As taxas de sobrevivência foram 97,1% e 91,9% para núcleos metálicos fundidos e pinos de fibra de vidro respectivamente. Quatro falhas foram observadas: duas descimentações de pinos de fibra de vidro (pré-molar e dente anterior), uma descimentação de pino de fibra de vidro associada a fratura radicular (pré-molar) e uma fratura radicular associada ao uso de núcleo metálico fundido (molar). Conclui-se que a literatura sugere que o uso de cimento resinoso autoadesivo poderia ajudar a conseguir maior resistência de pinos de fibra vidro ao canal radicular e que após 3 anos, ambos os pinos apresentaram performance semelhante
20

Uso de materiais diretos e indiretos para amplas restaurações: implicações clínicas e laboratoriais / Use of direct and indirect materials for extensive restorations: clinical and laboratory implications

Skupien, Jovito Adiel 14 March 2014 (has links)
Made available in DSpace on 2014-08-20T14:30:19Z (GMT). No. of bitstreams: 1 Tese_Jovito_Adiel_Skupien.pdf: 8297294 bytes, checksum: 72ce694b2bb9e499cf0353c4c4b8df4e (MD5) Previous issue date: 2014-03-14 / Glass fiber posts and composite resins are widely used materials in restorative dentistry. The various forms of presentation and technical approach, as well as different handling prior to their use, can result in diverse outcomes, which can determine the success or failure of the restorative procedure. Thus, the aim of this study was to evaluate the performance of glass fiber posts and composite resins in front of several factors related to it uses in dentistry. For this, the study was divided into three parts: An in vitro study, an in vivo study and a systematic review. The in vitro study aimed to evaluate the effect of cementation delay of indirect composite resin restorations in previously hybridized dentin. Three strategies of cementation were tested through different protocols. Beam-shaped specimens from tooth/restoration were obtained and submitted to microtensile testing to evaluate the bond strength and types of failures, where the results were analyzed by ANOVA and Tukey s post hoc tests and linear regression. Regular cement and adhesive threestep etch-and-rinse adhesive system showed the highest values of bond strength, followed by the same cement and two-step etch-and-rinse adhesive system and the lowest values for self-adhesive cement groups. Linear regression showed an improvement in the bond strength values when three-step adhesive system was used, however, all groups had adequate values of bond strength, even in unfavorable situations. The randomized clinical trial evaluated the longevity of metal-ceramic crown and composite resin restorations performed in endodontically treated teeth that received a glass fiber post. Fifty-six severely damaged teeth but with at least one entire wall were randomly allocated into two groups according to the type of restoration. The longevity was assessed through Kaplan-meier and clinical evaluation by descriptive analysis. The recall rate was 100%, fifty-six teeth were re-evaluated with no absolute failure. However, eight composite resin restorations had failed (all reparable). A significant difference between type of restoration was found. Indirect restorations provided higher acceptable clinical performance after two-year of followup, although composite failures were liable to repair. The systematic review compared factorts that can influence retention of glass fiber posts to intraradicular based on in vitro studies which compared the bond strength of resin cements. Searches were carried out in Pubmed and Scopus database up to December 2013. Thirty-four studies were included in the review and several variables were extracted. The presence of endodontic treatment significantly decrease the bond strength, meanwhile other variables can influence according to the type of resin cement. Thus, factors as type of cement application and pretreatment of post can influence glass fiber post retention, however, self-adhesive resin cements are less sensitive to luting procedures / Pinos de fibra de vidro e resinas compostas são materiais amplamente utilizados em odontologia restauradora. As diferentes formas de apresentação e técnicas de emprego, bem como diferentes manobras prévias às suas utilizações podem implicar em desfechos clínicos mais ou menos favoráveis, que podem determinar o sucesso ou falha de um procedimento restaurador. Assim, o objetivo deste estudo foi avaliar o desempenho de pinos de fibra de vidro e resinas compostas frente a diversos fatores relacionados ao seu uso em odontologia. Para isso, o estudo foi dividido em três partes: estudo in vitro, estudo in vivo e revisão sistemática. O estudo in vitro objetivou avaliar o efeito do retardamento da cimentação de restaurações indiretas de resinas compostas em dentina previamente hibridizada. Três estratégias de cimentação foram testadas com diferentes protocolos. Palitos do conjunto dente/restauração foram obtidos e submetidos ao teste de microtração para avaliação da resistência de união e padrão de fratura, onde os valores foram analisados através de ANOVA e teste post hoc Tukey (!=0,05) e regressão linear. Cimento convencional e sistema adesivo de 3 passos apresentaram os maiores valores de resistência de união, seguidos do mesmo cimento e sistema de 2 passos, sendo os menores valores para o grupo do cimento auto-adesivo. A regressão linear demonstrou uma melhora significativa nos valores de resistência quando o sistema de 3 passos foi utilizado, entretanto, todos os grupos tiveram resultados adequados, mesmo em condições desfavoráveis. O ensaio controlado randomizado avaliou a longevidade de restaurações metalo-cerâmicas e de resinas compostas confeccionadas em dentes tratados endodonticamente que receberam um pino de fibra de vidro. Cinqüenta e seis dentes com a coroa danificada, porém, com uma face intacta, foram alocados em dois grupos aleatoriamente, de acordo com o tipo de restauração. A longevidade das restaurações foi avaliadas através de Kaplan- Meier e critérios clínicos foram analisados de forma descritiva. Com uma taxa de rechamada de 100%, 56 dentes foram reavaliados e nenhum foi perdido. Porém, 8 restaurações de resina composta falharam e sofreram reparos. Houve uma diferença significativa para o tipo de restauração em relação ao sucesso. Assim, restaurações indiretas apresentaram uma melhor performance clínica após 2 anos de acompanhamento, embora as falhas apresentadas no grupo que recebeu resinas diretas tenham sido reparáveis. A revisão sistemática comparou fatores que podem influenciar na retenção de pinos de fibra de vidro em dentina intra-radicular baseado em estudos in vitro que compararam a resistência de união de cimentos resinosos. Após uma busca realizada nos bancos de dados Pubmed e Scopus até dezembro de 2013, trinta e quatro estudos foram incluídos na revisão e diferentes variáveis foram extraídas. A presença de tratamento endodôntico diminuiu significativamente a resistência de união, enquanto que demais variáveis variam sua influência de acordo com o tipo de cimento resinoso. Assim, fatores como método de aplicação do cimento e pré-tratamento do pino podem influenciar a retenção de pinos de fibra de vidro, porém, cimentos auto-adesivos são menos sensíveis à técnica de cimentação

Page generated in 0.0781 seconds