Spelling suggestions: "subject:"plumbing lemsystems"" "subject:"plumbing atemsystems""
1 |
Volatiles in Melt Inclusions from Mexican and Nicaraguan Volcanoes: Implications for Complex Degassing ProcessesAtlas, Zachary D. 04 August 2008 (has links)
The first section of this work examines melt inclusions in phenocrysts from Volcán Popocatépetl and Volcán de Colima within the Trans Mexican Volcanic Belt (TMVB). These inclusions are dacitic to rhyolitic. Trends in melt inclusion major element and water concentrations form the evolved extension of other Mexican volcanics including those presumably derived directly from primitive melts. Water concentrations in Popocatépetl and Colima melt inclusions are similar (0.3 to 3.4 weight percent Hsub2O). Melt-vapor equilibration pressures calculated from dissolved Hsub2O and COsub2 (Popocatépetl) or Hsub2O (Colima) in melt inclusions correspond to depths of entrapment of 12 km or less. Water and carbon dioxide concentrations correlate negatively with SiOsub2 and potassium. Normalized olivine-augite-quartz compositions are consistent with near cotectic crystallization under vapor-saturated conditions at pressures of 1.5 kb or less. Our results show that Popocatépetl and Colima magmas have undergone vapor-saturated crystallization during ascent in conjunction with varying degrees of mixing between degassed rhyo-dacitic and less degassed, mafic melts in the upper portions of the crust. These data suggest melt evolution occurred in conduits or inter-fingered dikes rather than a large stratified magma chamber. Part II looks at the Masaya caldera in Nicaragua. This volcano has erupted frequently in recorded history, producing lava lakes and very high gas emissions. Melt inclusions from Masaya are basaltic, with low Hsub2O (below 0.5 wt. %), low S (less than 300 ppm) and high COsub2 concentrations (up to approximately 6000 ppm). Relationships between water, sulfur, Cl and F in combination with Masaya's high COsub2 and Ba/Zr and Ba/Nb ratios suggest that Masaya has undergone a multi stage degassing process involving 1) shallow degassing, 2) recycling of magma into a deeper reservoir, and 3) fluxing of previously degassed magma with a nearly pure COsub2 vapor. Trace element signatures of melt inclusions are consistent with contributions that have been variably metasomatized by fluids generated by dehydration of subducted sediments and/or altered oceanic crust.
|
2 |
Gestão de agua em edificações : formulação de diretrizes para o reuso de agua para fins não potaveis / Water management in buildings : formulation of guidelines for the reuse water non potableBoni, Solange da Silva Nunes 14 August 2018 (has links)
Orientador: Marina Sangoi de Oliveira Ilha / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-14T17:19:44Z (GMT). No. of bitstreams: 1
Boni_SolangedaSilvaNunes_D.pdf: 2475928 bytes, checksum: 1748c60492975188a4888d1d5259fbc9 (MD5)
Previous issue date: 2009 / Resumo: Varias medidas de conservação de água tem sido adotadas visando minimizar o consumo de água, utilizando este insumo de maneira sustentável e racional, alem de proteger os recursos hídricos da poluição, por meio da geração de menor volume de esgoto. Dentre as linhas de ação dos programas de conservação de água em edifícios, destaca-se o reuso de água em atividades que possam prescindir da potabilidade. No entanto, para isso, e necessário o conhecimento dos diversos usos da água dentro de uma edificação, bem como determinar onde será possível utilizar este insumo, tendo como base um plano de gestão. Este trabalho propõe um conjunto de diretrizes para reuso de água para fins não potáveis em edificações, levando-se em consideração os riscos ocasionados com a utilização desta técnica. O método de pesquisa foi baseado em estudo de caso exploratório, de natureza fenomenológica, contando com duas fontes de evidencias: observação direta e entrevista. O Fator motivador do trabalho e o subsidio de diretrizes para a substituição de água potável por efluentes tratado, de forma a reduzir o consumo da edificação. O trabalho contou um estudo de caso em uma edificação existente, ocorrendo em duas fases distintas: caracterização da edificação e da demanda de água não potável e caracterização da oferta de fontes alternativas e a avaliação dos custos envolvidos para a implantação do sistema de reuso de água. Foi realizada a analise dos estudos e proposta as diretrizes para reuso de água para fins não potáveis, dentro dos contextos estudados. As diretrizes formuladas estão baseadas na complexidade das ações que envolvem a implantação do sistema de reuso, verificando-se a necessidade de estabelecimento de códigos de praticas e normas para implantar o referido sistema. / Abstract: Various measures to conserve water have been taken to minimize water consumption, using this input for sustainable and rational way, and protect water resources from pollution through the generation of lower quantity of sewage. Among the lines of action programs for water conservation in buildings, is the use of alternative sources to the public in activities that can disperse the drinking. However, for this reason it is necessary to know the various uses of water within a building and determine where you can use this input, based on a management plan. This paper proposes a set of guidelines for reuse of non-potable water in buildings, taking into account the risks incurred by using this technique. The research method was based on exploratory case study, a phenomenological, with two sources of evidence: direct observation and interview. The motivating factor is the work of the subsidy guidelines for the replacement of drinking water by treated effluent, to reduce the consumption of the building. The work had two case studies, one in an existing building and the other in design, occurring in two distinct phases: construction and characterization of the demand for non-drinking water and characterization of alternative sources of supply and assessment of the costs involved for deployment of the system for reuse of water. We performed the analysis of the studies and proposed guidelines for reuse of non-potable water, within the contexts studied. The guidelines are formulated based on the complexity of actions involving the deployment of the system for reuse, there is a need to establish codes of practice and standards to implement the system. / Doutorado / Arquitetura e Construção / Doutor em Engenharia Civil
|
3 |
Avaliação do uso de agua em edificios escolares publicos e analise de viabilidade economica da instalação de tecnologias economizadoras nos pontos de consumo / Water use evaluation in public schools buildings and economic feasibility analysis of installation of water saving technologiesYwashima, Lais Aparecida 23 February 2005 (has links)
Orientador: Marina Sangoi de Oliveira Ilha / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-04T11:15:45Z (GMT). No. of bitstreams: 1
Ywashima_LaisAparecida_M.pdf: 4111482 bytes, checksum: 8b37c02d441b73933d2437667f623e43 (MD5)
Previous issue date: 2005 / Resumo: O volume de água consumido em uma edificação, constante na conta de água, pode
ser dividido em duas parcelas: o uso propriamente dito e o desperdício. O desperdício pode ocorrer tanto pela ocorrência de vazamentos como pelo mau uso desse insumo nas diferentes atividades realizadas. Em edificações escolares públicas, é freqüente o uso não racional desse insumo, uma vez que os usuários não são os responsáveis diretos pelo pagamento da conta de água. Inserido nesse contexto, o presente trabalho apresenta a metodologia e os resultados obtidos em uma investigação de campo realizada com o objetivo de identificar a forma de realização das diferentes atividades que envolvem o uso da água em uma amostra de escolas da rede pública de Campinas, com a indicação dos ambientes responsáveis pelas maiores parcelas do consumo e a proposição de uma metodologia para a avaliação qualitativa da percepção dos usuários para o uso racional de água nessa tipologia de edificação. Além disso, tendo em vista que uma das ações para a implementação do uso racional consiste na instalação de tecnologias economizadoras nos pontos de consumo de água e que o fator motivador para a implementação desse tipo de intervenção é, na maioria das vezes, de ordem financeira, apresenta-se um método para a avaliação econômica dos investimentos necessários para tanto / Abstract: The water consumption, which is printed in water bills can be divided in two parts: the use itself and waste. The waste is usually due to leaking events or bad use of tap water in several daily activities. In public schools buildings, it¿s often the irrational use of water due the user is not directly responsible for paying the water bill. In this context, the present research presents the methodology and results obtained in a field survey that was done to identify different ways of water use in a sample of public schools from Campinas, Sao Paulo, and it also be done the identification of which environments are responsible for higher portions of the water consumption and the proposition of a methodology to evaluate the users perception for the rational use of water at this building type. Moreover, one of the alternatives to achieve the rational use of water is the installation of water saving technologies at consumption points and the motivator reason to the implementation of these devices it is, normally, financial issues, then, this work shows a method to evaluate economic feasibility of the essential investments to do it / Mestrado / Edificações / Mestre em Engenharia Civil
|
4 |
INVESTIGAÇÃO DO RUÍDO GERADO POR INSTALAÇÕES HIDROSSANITÁRIAS EM UMA EDIFICAÇÃO MULTIFAMILIAR / INVESTIGATION OF NOISE GENERATED PLUMBING SYSTEMS IN A MULTIFAMILY RESIDENTIAL BUILDINGPavanello, Lívia Ribeiro 14 August 2014 (has links)
In Brazil, the noise generated by plumbing systems into buildings is still little studied. Despite residents of multi-family vertical building citing this pathology as a cause of discomfort and complaints, there is not yet a standard that regulate noise measurements of hydrosanitary installations in the country in loco. This paper has as objective to establish an adequate measurement procedure of sound pressure level based in ISO 16032 (ISO, 2004) appropriate to evaluation the noise of plumbing systems, executed according to national standards, aiming to provide acoustic comfort to users. To verify the standard applicability, a 10 floor residential building, not inhabited yet, in the city of Santa Maria, with reinforced concrete structure and masonry wall, was chosen. The hydrosanitary devices measured were the faucet of the sink and the flushing cistern of the toilet bowl, both located in the master bathroom of the background apartments. The measurements was realized in suites, in 5 floors, and in the master bathroom of the 9th floor. The general rule was that the sanitary devices to be measured were triggered in the master bathroom, of the autonomous unit situated 1 floor above the suite, where was the microphone. However, exceptions occurred on the 10th and on the 7th floor, where measurements were made relating to hydrosanitary devices of the same floor and of two floors above, respectively. Therefore were measured and subsequently analyzed, all quantities allowed by ISO 16032 (ISO, 2004), in the weighting A and C, they are: Leq,nT, LFmax,nT and LSmax,nT. Were also performed measurements of the reverberation time of the suites according to ISO 3382-2 (ISO, 2008). After analyzing the results, it was found that in the situation of measurements, some results of the sink were influenced or masked by residual noise. Finally, to ensure the usefulness of the measurement procedure used, the results were compared with unique values expressed in NBR 15575-6 (ABNT, 2013) and was then evaluated the performance of hydrosanitary installations of the building, in situations that apply to standard. It is considered, therefore, that this paper contributed to the improvement of studies that search to enlarge the acoustic comfort in the Brazilian buildings, to establish measurement procedure of sound pressure level for the noise evaluation of plumbing systems. / No Brasil, o ruído gerado pelas instalações prediais hidrossanitárias ainda é pouco estudado. Apesar dessa patologia seguidamente ser citada como motivo de desconforto e reclamações, por parte de moradores de edificações residenciais multifamiliares verticais, ainda não há no país uma norma que regulamente medições de ruído de instalações hidrossanitárias in loco. Este trabalho teve como objetivo estabelecer um procedimento de medição dos níveis de pressão sonora, com base na ISO 16032 (ISO, 2004), apropriado para avaliação de ruído de instalações hidrossanitárias executadas conforme os padrões brasileiros, visando proporcionar conforto acústico aos usuários. Para a verificação da aplicabilidade da norma, foi escolhido um prédio residencial de 10 pavimentos, ainda não habitado, na cidade de Santa Maria, com estrutura de concreto armado e paredes de alvenaria. Os aparelhos hidrossanitários medidos foram a torneira do lavatório e a caixa de descarga da bacia sanitária, ambos localizados no banheiro da suíte dos apartamentos de fundo. As medições foram realizadas nas suítes em cinco diferentes pavimentos e no banheiro da suíte do 9º andar. Por norma, os aparelhos sanitários a serem medidos são acionados no banheiro da unidade autônoma situada um pavimento acima de onde se instala o microfone. Isso foi realizado e, além disso, no 10º e no 7º pavimento realizaram-se medições referentes aos aparelhos hidrossanitários do mesmo pavimento e de dois pavimentos acima, respectivamente. Foram medidas e, posteriormente analisadas, todas as grandezas recomendadas pela ISO 16032 (ISO, 2004), nas ponderações A e C, são elas: Leq,nT, LFmax,nT e LSmax,nT. Também foram realizadas medições do tempo de reverberação das suítes, segundo a ISO 3382-2 (ISO, 2008). Após a análise dos resultados, foi constatado que, na situação das medições, houve resultados do lavatório que foram influenciados ou mascarados pelo ruído residual. Por fim, para garantir a utilidade do procedimento de medição adotado, os resultados foram comparados com os valores únicos expressos na NBR 15575-6 (ABNT, 2013) e foi, então, avaliado o desempenho das instalações hidrossanitárias da edificação, nas situações que se aplicam à norma. Considera-se, portanto, que esse trabalho contribuiu para o avanço dos estudos que buscam ampliar o conforto acústico nas edificações brasileiras, ao estabelecer um procedimento de medição dos níveis de pressão sonora para avaliação do ruído de instalações hidrossanitárias.
|
5 |
Two Issues in Premise Plumbing: Contamination Intrusion at Service Line and Choosing Alternative Plumbing MaterialLee, Juneseok 01 May 2008 (has links)
Worldwide water distribution infrastructure system is old and deteriorating. A water system with its myriad appurtenances (including pumps and valves and tanks) is susceptible to hydraulic transients resulting in high and low pressure waves alternatively passing through the network. While both low and high pressure events structurally tax the already weak system, there is copious evidence indicating intrusion of contaminants into the drinking water pipes from the pipe's exterior environment due to low pressure events associated with water hammer phenomenon. These contaminants enter into the drinking water as the home plumbing system is a passive recipient from the water main. While the major (municipal) system is readily recognized as a vast infrastructure system of nearly 1,409,800 km of piping within the United States, the minor (plumbing) system that is at least 5 to 10 times larger is generally not well analyzed. In this study, an experimental plumbing rig was designed and implemented that replicates the range of pressures encountered in actual minor water distribution systems. This research addresses how a pressure transient triggered within a house and from municipal systems can impact the service line with a possible suction effect. Experimental results on low pressure events and the accompanying numerical modeling showed good agreement. The experiment also enabled visualization of the various pressure transient phenomena. It is demonstrated that hydraulic transients triggered from water mains result in low pressures events (up to -10 psig) in service lines which can allow possible intrusion of microbial and chemical contaminants at the service line. Structural integrity of service line and hydraulic integrity at water mains should be maintained to minimize any public health risks.
In the USA, about 90% of residential drinking water plumbing systems use copper pipes. Pinhole leaks in copper plumbing pipes have become a nationwide concern because these leaks cause property damage, lower property values, and result in possibility of adversely affecting homeowners' insurance coverage. In addition, resulting mold damage may cause health concerns. This research also addresses the concerns of the affected homeowners by enabling them to decide on whether to continue to repair or replace their plumbing system, the factors to be considered in a replacement decision, and the type of material to use for replacement. Plastic pipes such as PEX (cross-linked polyethylene), CPVC (Chlorinated Polyvinyl Chloride), and copper are considered in present analysis. Other alternatives include an epoxy coating technique on the existing piping systems, without the need to tear into walls. Multiple attributes of a plumbing system including cost (material plus labor charges), taste and odor impacts, potential for corrosion, longevity of the pipe system, fire retardance, convenience of installation or replacement, plumber or general contractor's opinions or expertise, and proven record in the market are considered. Attributes and material rankings are formalized within the framework of the preference elicitation tools namely AHP (Analytical Hierarchical Process). Surveys are conducted with selected homeowners in pinhole leak prone area in Southeastern US Community to observe their revealed and stated preferences. Participants' overall preference tradeoffs are reported in addition to comparing their revealed and stated preferences. Health effects, taste and odor of water turned out to be the most important factors from the survey. In real life, however, homeowners were not well aware of these safety issues related with plumbing materials. It is recommended that water professionals should work on bridging the gap between public perception and research results related to major and minor systems. / Ph. D.
|
6 |
Diretrizes para o gerenciamento da água pluvial nas edificações escolares municipais da cidade de Ribeirão Preto. / Guidelines on rainwater management for Ribeirão Preto municipal school buildings.Hernandes, André Teixeira 31 August 2006 (has links)
Made available in DSpace on 2016-06-02T20:09:05Z (GMT). No. of bitstreams: 1
DissATH.pdf: 18368287 bytes, checksum: b45251643897100029d341df26cf3598 (MD5)
Previous issue date: 2006-08-31 / The current projects of rainwater plumbing systems are extremely simple and present
only one exclusive concern: to divert the rainfall from the place where it occurs to the
drainage public system. In general, it s possible to verify that they do not attend even
the word semantic meaning. The no existence of a coordinated set of action aiming at
ampler results makes rainwater plumbing system unconcerned with the surrounding
area, not composing harmonically with the urban site in particular, and the environment
as a general form. Generally, designers expect only rainwater goes toward out of the
site, and that is a good result of a good system. Due the lack of attention to the impact
that generates and does harm to society, they ignore its potential as instrument of
water building conservation. They do not assess correctly its capacity as a source of
supply of so expensive and scarce water, according with its necessities, conveniences
or limitations that can exist.
Therefore, the goal of this study is to propose a new function for the rainwater plumbing
system, in special for Ribeirão Preto municipal school buildings, becoming it from a
passive to an active system of environment protection. With a proper and molded
conception for this new proposal, the system must contemplate the aspects related to
the reduction of the impacts caused by the civil construction activities on urban sites, its
preservation and providing environment education for people and also, as an worthy
water building management tool. / Os atuais projetos dos sistemas prediais de água pluvial são em sua grande
maioria, extremamente simples, apresentando uma única e exclusiva preocupação: a
transferência da precipitação do local onde ocorre para o sistema público de
drenagem, constituído por sarjetas, galerias e por fim, os córregos e rios. Verifica-se
que, em geral, não atendem nem ao sentido semântico da palavra sistema. A
inexistência de um conjunto coordenado de ações visando um resultado mais amplo
faz com que o sistema predial de água pluvial se dissocie de seu entorno, sem se
compor harmônicamente com o meio urbano em particular, e o meio natural de uma
forma geral. Na concepção atual de seus projetistas, o simples encaminhamento
destas águas para fora da edificação é o resultado esperado de um bom sistema.
Alheios ao impacto que gera e que penaliza a socidade, passam ao largo de seu
potencial como instrumento de conservação de água nas edificações. Ignoram sua
capacidade de suprir as mesmas com tão caro e cada vez mais escasso recurso, de
acordo com as necessidades, conveniências ou limitações que possam existir.
Portanto, o objetivo deste trabalho consiste na proposição de uma nova função para o
sistema predial de água pluvial, em especial nas escolas muncipais de Ribeirão Preto,
transformando-o de um sistema passivo de captação e drenagem em um sistema ativo
de conservação ambiental. Com uma concepção própria e moldada para esta nova
proposta, o sistema deve contemplar os aspectos relacionados à redução dos
impactos causados pela ocupação do solo no meio urbano, à preservação e educação
ambiental e também, à gestão da oferta de água nas edificações.
|
7 |
Aproveitamento de água pluvial em edifícios residenciais multifamiliares na cidade de São Carlos. / Rainwater harvesting in a residential tall building in the city of São Carlos.Campos, Marcus André Siqueira 06 May 2004 (has links)
Made available in DSpace on 2016-06-02T20:09:10Z (GMT). No. of bitstreams: 1
DissMASC.pdf: 3170204 bytes, checksum: 83bd0768232793a648b29a0d4da7f753 (MD5)
Previous issue date: 2004-05-06 / Financiadora de Estudos e Projetos / The potable water scarcity afflicts the begging of the 21st Century, being today, one of the
main worries of the manhood. This way, it becomes necessary to reduce the per capita
consumption.
From the actions that promote the racional use of water, the technological ones seems to be ,
in the most of the cases, the most recomended to reduce the consumption without being necessary
radical changes of the users. One of these technologies is the rainwater harvesting. This one erges as
an action of good perspectives since it subistitutes the use of potable water in activities where it is
not necessary a good quality water, younder, it will reduce the amount of stormwater in the public
drainage net, working as a non-structural action of urban drainage.
The lack of kwondlege as well a the real advantages that a rainwater system can bring to a
builind, is the points to find out about this issue.. At this paper, it seeked to clear this techonolgy up
with the study of national and international examples .
It also seeked the cistern sizing, getting the best results to technical and economical issues,
as well, as procedures to design and to mantain the devices that make part of the system used in this
study.
Besides that, it studied the changes that would be necessary to build the system, and the
possibles changes at the work routine of the construction company. It also studied the financial
feasibility of the investiment of this interprisement, checking the real economical advantages that
can be get.
It is waited that this research contributes to the development of this techonology, contributing
to Racional use of water in residential tall buildings. / A escassez de água potável atormenta o início do Século XXI, sendo hoje uma das principais
preocupações da humanidade neste século que começa. Dessa forma, surge a necessidade de
redução do consumo per capita.
Dentre as ações que promovem o uso racional da água, as tecnológicas parecem ser , na maioria dos
casos, as mais recomendadas para reduzir o consumo sem que seja necessário mudanças radicais
nos hábitos dos usuários. Entre estas, o aproveitamento de água pluvial surge como uma ação de
boas perspectivas, pois substitui o uso de água potável onde a qualidade desta não é necessária e, a
retirada desta diminuirá a quantidade de volume de água pluvial lançada na rede pública de
drenagem, funcionando como uma medida não-estrutural de drenagem urbana.
A falta de conhecimento técnico bem como das reais vantagens que um sistema de aproveitamento
de água pluvial poderá trazer para uma edificação são as principais incógnitas desse assunto. Neste
trabalho buscou-se clarear a tecnologia, com o estudo de diversos casos nacionais e internacionais.
Também se buscou realizar o dimensionamento de forma mais correta e econômica, bem como
listar procedimentos para elaboração e manutenção de todos os elementos constituintes do sistema
utilizado no edifício objeto de estudo.
Além disto, verificou-se as possíveis interferências nos processos construtivos, além de alterações
das rotinas de trabalho da construtora, além do estudo da viabilidade financeira do empreendimento,
verificando as reais vantagens da implantação do sistema neste caso.
Espera-se que esse trabalho contribua para o desenvolvimento de uma tecnologia específica para o
uso racional de água.
|
8 |
Diretrizes para licitações de projetos de sistemas prediais de água fria e esgoto sanitário em campi universitáriosCover, Marcelo Pinarelli 31 July 2012 (has links)
Made available in DSpace on 2016-06-02T20:09:16Z (GMT). No. of bitstreams: 1
4449.pdf: 2769612 bytes, checksum: e3079cd0b8c8a33fb2955ef26b04de84 (MD5)
Previous issue date: 2012-07-31 / In the context of the plumbing systems, the design stage may be responsable for considerable parcel of pathological manifestations that may occur after the building occupation. These problems can bring negative impact for the users, considering the built environment, and also demands premature maintenance with respective extra costs, which may decrease the building lifetime. In this context, this dissertation aims to propose guidelines that can be used in the bidding for projects of building systems of cold water and sanitary sewer in university campuses. The method used for the research was the case study. Firstable, a bibliographic survey was carried out by addressing the systems studied, the concepts of performance evaluations, as well as a collection of studies on pathologies, that had served to appraise the work. The guidelines, final result of this research, was developed, based on a survey of criteria and performance requirements present in the NBR 15575: 2008 Residential buildings of up to five floors Performance (ABNT, 2008), and based else in the author experience in the area. After that, two projetcs on Campus Are Carlos from the Federal University of São Carlos were analysed, as practice demonstration of the obtained results. / No contexto dos Sistemas Prediais Hidráulicos e Sanitários (SPHS), a etapa projeto pode ser a responsável por considerável parcela de manifestações patológicas que venham a surgir na edificação após sua ocupação. O surgimento de tais problemas impacta negativamente a qualidade do ambiente, gerando uma demanda precoce por manutenções corretivas, tendo como consequência maiores custos, e reduzindo a vida útil do sistema. Neste contexto, a presente dissertação tem como objetivo propor diretrizes que possam ser utilizadas em licitações de projetos de sistemas prediais de água fria (SPAF) e de esgoto sanitário (SPES) em campi universitários. O método utilizado para a obtenção dos resultados foi o estudo de caso. Inicialmente foi realizado um levantamento bibliográfico abordando os sistemas estudados, conceitos de desempenho, assim como uma coletânea de estudos sobre manifestações patológicas, que serviram para conceituar o trabalho. As diretrizes, resultado final da pesquisa, foram então desenvolvidas, com base em um levantamento de requisitos e critérios de desempenho para projetos presentes na NBR 15575-6: Desempenho de edifícios habitacionais de até 5 pavimentos Desempenho Parte 6: Sistemas hidrossanitários (ABNT, 2008) e na experiência do autor na área. A seguir essas diretrizes foram aplicadas em dois projetos no Campus São Carlos da Universidade Federal de São Carlos, e feita a análise dos resultados. Palavras-chave: Construção Civil. Sistemas Prediais. Projeto. Diretrizes. Patologia das Construções. Cover, Marcelo P. Guidelines for bidding for projects of building systems of cold water and sanitary sewage in university campuses. São Carlos SP. Civil Engineering Department, Federal University of São Carlos, 2012. 117 pages. Master Dissertation.
|
9 |
Zdravotně technické instalace ubytovacích zařízení / Plumbing Systems for Accommodation FacilitiesMožná, Pavlína January 2013 (has links)
Master’s thesis "Plumbing systems for accommodation facilities" is processed in the form of project documentation plumbing according to applicable regulations. Designed building has five floors, basement. The ground floor restaurant and relaxing part of the hotel, in the remaining floors are guest rooms with 75 beds. One room is completely wheelchair. The building is located outside urban areas without connection to public utilities. The work focuses on the design of plumbing hotel and presents two variants of the possible solutions for waste water from the building. Building water supply is secured from drilled wells and the proposed pumping equipment.
|
10 |
Zdravotně technické instalace v hotelu s lázeňským provozem / Sanitation installation in a hotel with health resortŠimon, Michal January 2014 (has links)
Thesis: Sanitation installation in a hotel with health resort The unit has 6 floors, it is partly with a cellar. The 1st floor is intended for spa purposes, the floors 3-5 serve as the acommodation area and in the 6th floor there is a machine room. The theoretic part is focused on the water problematics, on the type of sewages, including the labeling of their colors, and the following secondary use of the sewages. The next step is the choosing of the appropriate obtion. The project concerns the sanitation installation in a hotel with health resort.
|
Page generated in 0.0532 seconds