• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 9
  • Tagged with
  • 9
  • 9
  • 9
  • 9
  • 8
  • 6
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

LIBS e nanopartículas fluorescentes : novas estratégias para determinação de íons Cu(II) em águas / LIBS and fluorescent nanoparticles : new strategies for the determination of Cu(II) ions in water

Santos, Klecia Morais dos, 1979- 20 August 2018 (has links)
Orientador: Ivo Milton Raimundo Júnior / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Química / Made available in DSpace on 2018-08-20T16:51:10Z (GMT). No. of bitstreams: 1 Santos_KleciaMoraisdos_D.pdf: 2306751 bytes, checksum: bf7642f623ca7798b881b810cd6dd821 (MD5) Previous issue date: 2012 / Resumo: Neste trabalho diferentes fases sensoras foram desenvolvidas para implementar novas estratégias para a determinação de íons cobre em águas naturais, empregando Espectroscopia Óptica de Emissão em Plasma Induzido por Laser (LIBS) e Espectroscopia de Luminescência. Nas determinações por LIBS, membranas de PVC plastificadas foram empregadas para extração e pré-concentração de íons cobre em meio aquoso, fornecendo curvas analíticas na faixa de 10 mg L - 100mg L (R > 0,90). Esses estudos mostraram que a técnica LIBS é capaz de detectar íons cobre em concentrações da ordem de mg L, indicando que membranas extratoras podem ser aplicadas como uma eficiente estratégia de pré-concentração. Dessa forma, LIBS pode ser considerada como uma potencial e viável ferramenta para determinação de íons Cu(II) em águas. Determinações baseadas em Espectroscopia de Luminescência foram realizadas usando o bis(1,10-fenantrolina)1-(4-hidroxi 3-(1H-imidazol [4,5-f][1,10] rutênio(II) bis hexafluorofosfato ([Ru(phen)2HAIP](PF6)2), que foi imobilizado em membranas de metacrilato, de PVC e iônicas, sol-gel e nanopartículas (NP) de sílica. O reagente luminescente apresenta alta seletividade para íons Cu (II) em solução, enquanto somente as nanopartículas mostraram sensibilidade adequada para esse íon. As nanopartículas de sílica foram sintetizadas através do método Stöber, sendo que o reagente luminescente foi adicionado em diferentes estágios da síntese (0, 3, 6 e 8 horas), a qual foi realizada em um total de 10 horas. A microscopia de transição eletrônica (TEM) mostrou nanopartículas com diâmetros em torno de 10-20 nm. As nanopartículas sintetizadas pela adição do reagente após 8h de síntese apresentaram uma faixa linear entre 2,0-8,0 mmol L, um limite de detecção de 0,30 mmol L, um limite de quantificação de 1,0 mmol L e um tempo de resposta (t90%) < 30 s. A nanopartícula apresentou alta seletividade para íons cobre, não mostrando interferências dos íons Zn(II), Cd(II), Ni(II), Hg(II), Pb(II) e Fe(III). As nanopartículas foram aplicadas para determinação de íons Cu(II) em amostras de água mineral e de torneira que foram enriquecidas com 5,0 e 7,0 mmol L do analito. Recuperações na faixa de 88,1-109,6% foram obtidas, indicando a potencialidade das NPs fluorescentes para determinação de Cu(II) em águas. Além disso, os íons Cu (II) podem ser liberados na NP depois de tratamento ácido, sendo regenerado para um novo conjunto de medidas, tornando o reagente reutilizável, fato que está de acordo com os princípios da Química Verde / Abstract: In this work, different sensing phases were developed to implement new strategies for determination of copper ions in natural waters, employing Laser Induced Breakdown Spectroscopy (LIBS) and Luminescence Spectroscopy. In the determinations by LIBS, plasticized PVC membranes were employed for extraction and pre-concentration of copper ions in aqueous medium, providing analytical curves in the range from 10 mg L to 100mg L (R > 0.90). These studies have shown that LIBS is able to detect copper ions in concentrations as low as mg L, indicating that extraction membranes can be applied as an efficient strategy of pre-concentration. In this way, LIBS can be considered as a potential and feasible tool for Cu(II) determination in waters. Determinations based on luminescence spectroscopy were performed by using the bis(1,10-phenanthroline)1-(4-hydroxy 3-(1H-imidazo [4,5-f][1,10] ruthenium(II) bis(hexafluorophosphate) reagent ([Ru(phen)2HAIP](PF6)2), which was immobilized in methacrylate, PVC and ionic membranes, sol-gel silica and silica nanoparticles (NP). The luminescent reagent presented high selectivity to Cu(II) ions in solution, while only the silica nanoparticles showed adequate sensitivity to this ion. The nanoparticles were synthesized by the Stöber method, being the luminescent reagent added at different stages of the synthesis (0, 3, 6 and 8 hours), which was a performed in a total interval of 10 hours. The transmission electron microscopy (TEM) showed nanoparticles with diameters around 10-20 nm. The nanoparticles synthesized by adding the reagent after 8 hours provided a linear response range from 2.0 to 8.0 mmol L, a detection limit of a 0.30 mmol L, a quantification limit of 1.0 mmol L and response time (t90%) < 30 s. The nanoparticle presented high selectivity for copper ions, showing no interference of Zn(II), Cd(II), Ni(II), Hg(II), Pb(II) and Fe(III) ions. The nanoparticles were applied to determination of Cu(II) ions in mineral and tap water samples, which were spiked with 5.0 and 7.0 mmol L of the analyte. Recovery within 88.1-109.6% were attained, indicating the capability of the fluorescent NPs for Cu(II) determination in waters. In addition, the Cu(II) ions can be released from the NP by acidic treatment, being regenerated for another set of measurements, making the reagent reusable, fact that is in agreement with the principles of Green Chemistry / Doutorado / Quimica Analitica / Doutor em Ciências
2

Desenvolvimento e aplicação de polímeros de impressão molecular em extração em fase sólida para determinação de fluoxetina em efluente

Bianchi, Viviane do Nascimento January 2017 (has links)
Orientadora: Profa Dra Elizabete Campos de Lima / Dissertação (mestrado) - Universidade Federal do ABC, Programa de Pós-Graduação em Ciência e Tecnologia Ambiental, 2017. / Nos efluentes, estão presentes as mais variadas misturas de fármacos, produtos de limpeza, de higiene, derivados de processos industriais, entre outros. Mesmo após o tratamento, estudos indicam que esses compostos podem continuar presentes, sendo despejados nos corpos hídricos, representando riscos para o ecossistema aquático, os quais só se tornam conhecidos após estudos científicos. Dentre essas substâncias, os fármacos são grandes representantes e a fluoxetina é um antidepressivo massivamente utilizado, capaz de promover alterações comportamentais em espécies aquáticas expostas a mesma concentração em que essa substância é encontrada em matrizes ambientais. Para controle de compostos considerados potencialmente nocivos ao ecossistema e à saúde humana, é indispensável conhecer suas concentrações em efluentes e corpos d'água. Contudo, esse tipo de matriz contém impurezas e compostos que não são de interesse, necessitando preparo de amostra para limpeza e pré-concentração do analito alvo. Nesse contexto, o objetivo deste trabalho foi desenvolver um polímero de impressão molecular para extração em fase sólida como preparo de amostra para determinação de fluoxetina em efluentes por cromatografia líquida acoplada a detector de arranjo de diodos, HPLC-DAD. Foram sintetizados polímeros de impressão molecular com ácido acrílico, ácido metacrílico e estireno como monômeros funcionais. Os rendimentos de síntese foram de 67,2% para estireno, 64,0% para ácido acrílico e 62,2% para ácido metacrílico. Foi avaliada a seletividade entre cafeína e fluoxetina, resultando em melhor afinidade do polímero com o antidepressivo. A adsorção ocorre como reação de pseudo segunda ordem, com melhor adsorção do polímero impresso do que o polímero não impresso. Ao aplicar a extração em fase sólida em efluente e analisá-lo pelo método HPLC-DAD desenvolvido e validado, o valor de recuperação do polímero molecularmente impresso (30,6%), apesar de estar abaixo do desejado, se mostrou bastante superior ao valor de recuperação do cartucho comercial C18 (2,1%). / In the sewage, there are the most varied mixtures of medicines, cleaning products, hygiene products, industrial processes derivatives, among others. Even after treatment, studies indicate that these compounds may remain in wastewater, being discharged into the water bodies, representing risks to the aquatic ecosystem, risks which only become known after scientific studies. Among these substances, the pharmaceuticals are great representatives and fluoxetine is a massively used antidepressant, capable of promoting behavioral changes in aquatic species exposed to the same concentration in which this substance is found in environmental matrices. For control of compounds considered potentially harmful to the ecosystem and to human health, it is indispensable to know their concentrations in effluents and water bodies. However, such matrix contains impurities and compounds that are not of interest, thus it is necessary some sample preparation for cleaning and preconcentration of the target analyte. In this context, the objective of this work was to develop a molecularly imprinted polymer for solid phase extraction as sample preparation for the determination of fluoxetine in effluents by liquid chromatography coupled to a diode arrangement detector, HPLC-DAD. Molecularly imprinted polymers were synthesized with acrylic acid, methacrylic acid and styrene as functional monomers. The yields of synthesis were 67.2% for styrene, 64.0% for acrylic acid and 62.2% for methacrylic acid. The selectivity between caffeine and fluoxetine was evaluated, resulting in better affinity of the polymer with the antidepressant. The adsorption occurs as a pseudo second order reaction, with better adsorption of the imprinted polymer than the non-imprinted polymer. By applying the solid phase extraction in effluent and analyzing it by the developed and validated HPLC-DAD method, the recovery value for the molecularly imprinted polymer (30.6%), although below the desired one, was shown to be much higher than the recovey value for commercial C18 cartridge (2.1%).
3

Materiais impressos molecularmente (MIMs) : síntese, caracterização e avaliação / Molecularly imprinted materials (MIMs) : synthesis, characterization and evaluation

Manzoor, Suryyia, 1984- 22 August 2018 (has links)
Orientadores: Adriana Vitorino Rossi, Regina Buffon / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Química / Made available in DSpace on 2018-08-22T19:48:13Z (GMT). No. of bitstreams: 1 Manzoor_Suryyia_D.pdf: 4523839 bytes, checksum: 9aa2a7bc8376699193b0d5e83f0ec0f5 (MD5) Previous issue date: 2013 / Resumo: Este trabalho envolveu um estudo elaborado da técnica de impressão molecular para síntese, caracterização e avaliação de materiais impressos molecularmente (MIMs) para fluconazol (FLU), cafeína (CAF) e antocianinas (ACYs). O polímero de impressão molecular para FLU (FLUMIP) foi sintetizado utilizando-se ácido metacrílico (monômero funcional), etilenoglicoldimetacrilato (EGDMA) (agente reticulador) e acetonitrila em polimerização térmica. O FLUMIP foi caracterizado e aplicado como sorvente em cartuchos de extração em fase sólida (SPE). Sua capacidade de interação seletiva com o analito foi avaliada, obtendo-se alta afinidade para FLU, em comparação com análogos estruturais, com limite de detecção menor que 1,63X10 mmol/L com cromatografia de ultra alta eficiência acoplada com espectrometria de massas. Este MIP foi usado em cartuchos de SPE para extrair o analito de medicamento em cápsula, com recuperação de 91±10 % (n=9). Outro MIM obtido foi uma sílica organicamente modificada (ORMOSIL) para extração de CAF, a partir da reação de metacrilato de 3- (trimetoxisilil) propila e acetato de vinila, seguindo-se condensação e hidrólise com tetraetilortosilicato usando CAF como molécula modelo. Este ORMOLSIL foi caracterizado e testado quanto à sua eficácia de extrair CAF de amostras de café, com recuperação de 88±5 % (n=9); ele atuou como grupo seletivo com alta porcentagem de recuperação para teofilina (77 %) e teobromina (82 %). Limites de detecção e quantificação 5,14x10 e 1,71x10 mmol/L respectivamente foram obtidos com cromatografia líquida de alta eficiência. Também foi sintetizado um MIP usando rutina molécula modelo (RUTMIP), acrilamida (monômero funcional), EGDMA (agente reticulador) e tetraidrofurano por polimerização em bulk. Embora tenha sido alcançada impressão bem sucedida de rutina, confirmada pela comparação de afinidade de RUTMIP em aplicação de SPE (12 vezes maior que afinidade do polímero não impresso), não se alcançou a seletividade esperada para ACYs utilizando o RUTMIP / Abstract: This work involves an elaborative study of molecularly imprinting technique. Keeping in view its robustness and selectivity, this technique was applied for the synthesis of molecularly imprinted materials for the extraction of fluconazole (FLU), caffeine (CAF) and anthocyanins (ACYs). Molecularly imprinted polymer (MIP) for FLU (FLUMIP) was synthesized using methacrylic acid (functional monomer), ethyleneglycoldimethacrylate (crosslinker) and acetonitrile through thermal polymerization. The FLUMIP was characterized and applied as sorbent in solid phase extraction (SPE) cartridges. It was then evaluated for its ability to selectively interact with the analyte and presented an apparent affinity for FLU, which was confirmed by comparing it with structural analogues. The application of ultra high performance liquid chromatography with spectrometer mass detection, allowed a limit of detection 1.63x10 mmol/L. Furthermore, the SPE procedure was applied to extract FLU from medicine samples with recovery of 91±10 % (n=9). An organically modified silica (ORMOSIL) for CAF was also synthesized by reacting vinyl acetate and 3- (trimethoxysilyl) propyl methacrylate, followed by the condensation and hydrolysis with tetraethyl orthosilicate, using CAF as template molecule. The ORMOSIL was characterized and tested for its efficiency to extract the analyte from coffee samples and the percentage recovery of 88±5 % (n=9) was obtained. The cross reactivity studies for theophylline and theobromine showed high recovery (77 % and 82% respectively). The limit of detection and quantification, 5.14x10 and 1.71x10 mmol/L respectively, were achieved using high performance liquid chromatography. Also, a MIP for ACYs (RUTMIP) was synthesized using rutin (template molecule), EGDMA (cross linker) and tetrahydrofuran by the bulk polymerization method. A successful imprinting of rutin was attained. This can be confirmed by the high affinity of rutin for MIP (12 times greater than non imprinted polymer) during SPE procedure; however, the RUTMIP was not efficient enough to selectively extract ACYs from vegetal extracts / Doutorado / Doutora em Ciências
4

Aplicação de eletrodos compósitos à base de grafite-poliuretana modificados com polímeros com impressão molecular, na determinação de ácido fólico e diclofenaco / Application of graphite-polyurethane composite electrodes modified with molecularly imprinted polymers in the determination of folic acid and diclofenac

Pereira, Abigail Vasconcelos 14 August 2015 (has links)
Neste trabalho foram preparados eletrodos compósitos grafite-poliuretana modificados com polímeros metacrilatos com impressão molecular (EGPU-MIP) visando a determinação de ácido fólico (FA) e forma ácida do diclofenaco (DCF), os quais foram usados como moléculas molde. O objetivo principal era avaliar o desempenho dos MIPs em relação à seletividade e sensibilidade, além da inovação em relação ao uso dos compósitos como material de eletrodo, relativamente a esses analitos. No caso do FA, os MIP foram preparados com essa molécula, relativamente grande e contendo vários grupos funcionais, para avaliar o efeito dessas características no desempenho do sensor. Inicialmente foram feitos estudos exploratórios usando voltametria cíclica (CV), nos quais o FA apresentou pico irreversível de oxidação em +0,80 V (vs. SCE) e picos reversíveis de redução em -0,40 e -0,65 V (vs. SCE), com respectivos processos de oxidação em -0,33 e -0,49 V (vs. SCE). Foi desenvolvido um procedimento analítico para determinação do fármaco usando voltametria de pulso diferencial (DPV), após otimizar parâmetros tais como composição de MIP no sensor de (2,5%, m/m), amplitude de pulso (a = 50 mV), velocidade de varredura (&nu; = 10 mV s-1) e meio eletrolítico (tampão acetato, pH = 4,5). Nesse procedimento, determinou-se uma mesma região linear de resposta entre 0,6 e 2,0 &micro;mol L-1 para os dois picos de redução em -0,52 e -0,58 V (vs. SCE), com limites de detecção (LOD) de 0,17 e de 0,03 &micromol L-1, respectivamente. O pico em -0,58 V mostrou-se mais sensível e foi escolhido para determinar o FA nas formulações farmacêuticas Folacin&reg, Afopic&reg e Folifolim&reg, com resultados concordantes com o método oficial baseado na Cromatografia líquida de alta eficiência (HPLC), em 95% de confiança, segundo o teste t-Student. O MIP-FA mostrou-se mais seletivo que o polímero sem impressão molecular (NIP-DCF) frente às interferências do metotrexato (MTX), porem o ácido ascórbico (AA), ácido úrico (UA) e dopamina (DA) mostraram interferências, em relação aos grupos funcionais presentes nessas espécies, com forte influência da rigidez estrutural e da mobilidade rotacional de tais grupos. Outro MIP foi sintetizado com impressão para DCF. A voltametria cíclica mostrou que o DCF apresenta pico irreversível de oxidação em + 0,83 V (vs. SCE), na primeira varredura e picos reversíveis de redução em +0,40 e +0,65 V (vs. SCE), a partir da segunda varredura, com respectivos processos de oxidação em +0,27 e +0,58 V (vs. SCE). Foi desenvolvido um procedimento analítico para determinação do fármaco em formulações comerciais, usando DPAdASV, após otimização dos parâmetros tais como composição de MIP no sensor (2,5%, m/m), tempo de acumulação (300 s) e potencial de pré-concentração (+0,2 V), a = 50 mV, &nu; = 10 mV s-1 em ácido perclórico pH condicional (pHcond) = 1,6, com uma região linear entre 0,010 e 0,20 nmol L-1 e LOD de 0,99 nmol L-1 para o pico anódico em +0,8 V (vs. SCE). O DCF foi determinado nas formulações farmacêuticas Biofenac&reg, Medley&reg e Voltaren&reg e em urina sintética. O MIP-DCF se mostrou relativamente seletivo ao sinal do DCF, mesmo na presença dos interferentes como ácido meclofenâmico (AMCFN) e ácido mefenâmico (AMFN), os quais apresentam grande semelhança estrutural e funcional em relação ao analito. Deve-se tomar cuidado ao estender o intervalo de potencial operacional para o GPU, neste meio de ácido perclórico, para evitar ativação de grupos funcionais do grafite e/ou da PU. / In this work methacrylate molecularly imprinted polymers (MIP) were prepared using folic acid (FA) as well as diclofenac (DCF) templates. These MIPs were used in the modification of graphite-polyurethane (GPU) composites in order to evaluate the performance of the resulting electrodes in the determination of the templates in pharmaceutical formulations and to estimate the sensitivity and selectivity of the resulting devices joined to the innovation of using the composites in such development regarding these analytes. In the case of FA, MIPs were prepared with this relatively large and containing multiple functional groups, to evaluate the effect of such characteristics in the performance of the sensor. First of all exploratory experiments were performed using cyclic votammetry (CV) in which the FA presented an irreversible oxidation peak at + 0.80 V (vs. SCE) and reversible reductions peaks at -0.40 and -0.65 V (vs. SCE) with respective oxidation at -0.33 and -0.49 V (vs. SCE). An analytical procedure was developed based on differential pulse voltammetry (DPV), after optimizing parameters such as MIP composition in the sensor (2.5%, m/m), pulse amplitude (a = 50 mV), scan rate (&nu; = 10 mV s-1) and supporting electrolyte (acetate, pH = 4.5). In such procedure was obtained a linear dynamic range from 0.6 to 2.0 &micromol L-1 for both DPV reduction peaks at -0.52 and -0.58 V (vs. SCE), with limit of detection (LOD) of 0.17 and 0.03 &micromol L-1, respectively. As the second on was more sensitive it was chosen for the determination of FA in the commercial pharmaceutical formulation Folacin&reg, Afopic&reg and Folifolim&reg,with results that agreed with those from the official HPLC procedure within 95% confidence level according to the t-Student test. The MIP-FA was more selective than the non-imprinted polymer (NIP-DCF) in relation to the interference of metotrexate (MTX), however ascorbic acid (AA), uric acid (UA) and dopamine (DA) revealed significant interferences regarding the functional groups present in these species, with strong influence from the structural rigidity of the molecule that plays an important role in the rotational mobility of these groups. Another MIP was synthesized with DCF as a template. Cyclic voltammetry demonstrated that the DCF presented a single irreversible oxidation peak at + 0.83 V (vs. SCE) in the first scan, and two reversible reduction peaks at +0.40 and +0.65 V (vs. SCE) with respective oxidation at +0.27 and +0.58 V (vs. SCE), from the second scan. A DPAdASV procedure was also developed for the determination of DCF in commercial formulations after optimizing some experimental parameters such as MIP composition in the sensor (2.5%, m/m), accumulation time (300 s) and potential (+0.2 V), a = 50 mV, v = 10 mV s-1 and supporting electrolyte (perchloric acid pHcond = 1.6). A linear dynamic range from 0.010 to 0.20 nmol L-1 and a LOD of 0.99 nmol L-1 were observed for the anodic peak at +0.8 V (vs. SCE). Then the DCF was determined in the commercial formulations Biofenac&reg, Medley&reg and Voltaren&reg and also in synthetic urine samples. The MIP-DCF sensor showed to be selective regarding the DCF signal even in the presence of meclophenamic acid (AMCFN) and mefenamic acid (AMFN), which present structural and functional similarity when compared with the analyte. Care must be taken when using the GPU in extreme potential windows in the perchloric acid medium, to avoid activation of functional groups in the polymer.
5

Aplicação de eletrodos compósitos à base de grafite-poliuretana modificados com polímeros com impressão molecular, na determinação de ácido fólico e diclofenaco / Application of graphite-polyurethane composite electrodes modified with molecularly imprinted polymers in the determination of folic acid and diclofenac

Abigail Vasconcelos Pereira 14 August 2015 (has links)
Neste trabalho foram preparados eletrodos compósitos grafite-poliuretana modificados com polímeros metacrilatos com impressão molecular (EGPU-MIP) visando a determinação de ácido fólico (FA) e forma ácida do diclofenaco (DCF), os quais foram usados como moléculas molde. O objetivo principal era avaliar o desempenho dos MIPs em relação à seletividade e sensibilidade, além da inovação em relação ao uso dos compósitos como material de eletrodo, relativamente a esses analitos. No caso do FA, os MIP foram preparados com essa molécula, relativamente grande e contendo vários grupos funcionais, para avaliar o efeito dessas características no desempenho do sensor. Inicialmente foram feitos estudos exploratórios usando voltametria cíclica (CV), nos quais o FA apresentou pico irreversível de oxidação em +0,80 V (vs. SCE) e picos reversíveis de redução em -0,40 e -0,65 V (vs. SCE), com respectivos processos de oxidação em -0,33 e -0,49 V (vs. SCE). Foi desenvolvido um procedimento analítico para determinação do fármaco usando voltametria de pulso diferencial (DPV), após otimizar parâmetros tais como composição de MIP no sensor de (2,5%, m/m), amplitude de pulso (a = 50 mV), velocidade de varredura (&nu; = 10 mV s-1) e meio eletrolítico (tampão acetato, pH = 4,5). Nesse procedimento, determinou-se uma mesma região linear de resposta entre 0,6 e 2,0 &micro;mol L-1 para os dois picos de redução em -0,52 e -0,58 V (vs. SCE), com limites de detecção (LOD) de 0,17 e de 0,03 &micromol L-1, respectivamente. O pico em -0,58 V mostrou-se mais sensível e foi escolhido para determinar o FA nas formulações farmacêuticas Folacin&reg, Afopic&reg e Folifolim&reg, com resultados concordantes com o método oficial baseado na Cromatografia líquida de alta eficiência (HPLC), em 95% de confiança, segundo o teste t-Student. O MIP-FA mostrou-se mais seletivo que o polímero sem impressão molecular (NIP-DCF) frente às interferências do metotrexato (MTX), porem o ácido ascórbico (AA), ácido úrico (UA) e dopamina (DA) mostraram interferências, em relação aos grupos funcionais presentes nessas espécies, com forte influência da rigidez estrutural e da mobilidade rotacional de tais grupos. Outro MIP foi sintetizado com impressão para DCF. A voltametria cíclica mostrou que o DCF apresenta pico irreversível de oxidação em + 0,83 V (vs. SCE), na primeira varredura e picos reversíveis de redução em +0,40 e +0,65 V (vs. SCE), a partir da segunda varredura, com respectivos processos de oxidação em +0,27 e +0,58 V (vs. SCE). Foi desenvolvido um procedimento analítico para determinação do fármaco em formulações comerciais, usando DPAdASV, após otimização dos parâmetros tais como composição de MIP no sensor (2,5%, m/m), tempo de acumulação (300 s) e potencial de pré-concentração (+0,2 V), a = 50 mV, &nu; = 10 mV s-1 em ácido perclórico pH condicional (pHcond) = 1,6, com uma região linear entre 0,010 e 0,20 nmol L-1 e LOD de 0,99 nmol L-1 para o pico anódico em +0,8 V (vs. SCE). O DCF foi determinado nas formulações farmacêuticas Biofenac&reg, Medley&reg e Voltaren&reg e em urina sintética. O MIP-DCF se mostrou relativamente seletivo ao sinal do DCF, mesmo na presença dos interferentes como ácido meclofenâmico (AMCFN) e ácido mefenâmico (AMFN), os quais apresentam grande semelhança estrutural e funcional em relação ao analito. Deve-se tomar cuidado ao estender o intervalo de potencial operacional para o GPU, neste meio de ácido perclórico, para evitar ativação de grupos funcionais do grafite e/ou da PU. / In this work methacrylate molecularly imprinted polymers (MIP) were prepared using folic acid (FA) as well as diclofenac (DCF) templates. These MIPs were used in the modification of graphite-polyurethane (GPU) composites in order to evaluate the performance of the resulting electrodes in the determination of the templates in pharmaceutical formulations and to estimate the sensitivity and selectivity of the resulting devices joined to the innovation of using the composites in such development regarding these analytes. In the case of FA, MIPs were prepared with this relatively large and containing multiple functional groups, to evaluate the effect of such characteristics in the performance of the sensor. First of all exploratory experiments were performed using cyclic votammetry (CV) in which the FA presented an irreversible oxidation peak at + 0.80 V (vs. SCE) and reversible reductions peaks at -0.40 and -0.65 V (vs. SCE) with respective oxidation at -0.33 and -0.49 V (vs. SCE). An analytical procedure was developed based on differential pulse voltammetry (DPV), after optimizing parameters such as MIP composition in the sensor (2.5%, m/m), pulse amplitude (a = 50 mV), scan rate (&nu; = 10 mV s-1) and supporting electrolyte (acetate, pH = 4.5). In such procedure was obtained a linear dynamic range from 0.6 to 2.0 &micromol L-1 for both DPV reduction peaks at -0.52 and -0.58 V (vs. SCE), with limit of detection (LOD) of 0.17 and 0.03 &micromol L-1, respectively. As the second on was more sensitive it was chosen for the determination of FA in the commercial pharmaceutical formulation Folacin&reg, Afopic&reg and Folifolim&reg,with results that agreed with those from the official HPLC procedure within 95% confidence level according to the t-Student test. The MIP-FA was more selective than the non-imprinted polymer (NIP-DCF) in relation to the interference of metotrexate (MTX), however ascorbic acid (AA), uric acid (UA) and dopamine (DA) revealed significant interferences regarding the functional groups present in these species, with strong influence from the structural rigidity of the molecule that plays an important role in the rotational mobility of these groups. Another MIP was synthesized with DCF as a template. Cyclic voltammetry demonstrated that the DCF presented a single irreversible oxidation peak at + 0.83 V (vs. SCE) in the first scan, and two reversible reduction peaks at +0.40 and +0.65 V (vs. SCE) with respective oxidation at +0.27 and +0.58 V (vs. SCE), from the second scan. A DPAdASV procedure was also developed for the determination of DCF in commercial formulations after optimizing some experimental parameters such as MIP composition in the sensor (2.5%, m/m), accumulation time (300 s) and potential (+0.2 V), a = 50 mV, v = 10 mV s-1 and supporting electrolyte (perchloric acid pHcond = 1.6). A linear dynamic range from 0.010 to 0.20 nmol L-1 and a LOD of 0.99 nmol L-1 were observed for the anodic peak at +0.8 V (vs. SCE). Then the DCF was determined in the commercial formulations Biofenac&reg, Medley&reg and Voltaren&reg and also in synthetic urine samples. The MIP-DCF sensor showed to be selective regarding the DCF signal even in the presence of meclophenamic acid (AMCFN) and mefenamic acid (AMFN), which present structural and functional similarity when compared with the analyte. Care must be taken when using the GPU in extreme potential windows in the perchloric acid medium, to avoid activation of functional groups in the polymer.
6

Desenvolvimento e aplicação de plataformas fundamentadas na tecnologia dos polímeros impressos molecularmente para detecção de 4-nitrofeno / Development and application of platforms based on polymer molecularly imprinted technology for detection of 4-nitrofenol

Cordeiro, Walker de Lima 20 June 2017 (has links)
The present work describes the development of a highly sensitive and selective molecularly imprinted electrochemical sensor for 4-nitrophenol detection. A glassy carbon electrode was modified with vyniltrimethoxisylane (VTMS) and multiwall carbon nanotubes (MWCNT). The introduced nanocomposite increased surface area and active sites for electron transfer. When the sillane is used on the synthesis, it is named MIS (molecularly imprinted silane) and NIS (non-imprinted silane) when the analyte is not on the synthesis. For those silane films characterization, it was used the scanning electron microscopy (SEM), thermogravimetric analysis (TGA) and fourier transform infrared spectroscopy (FTIR). This sensor showed its best performance in 0.1 mol L-1 phosphate buffer solution, at pH 7.0. After optimizing the operational conditions, this sensor provided a linear response range for 4-NP from 0.1 up to 100 μmol L-1 and good parameters as LOD, LOQ and sensibility, 0.03 μmol L-1, 0.1 μmol L-1 and 1.4×10-2 A mol L-1 respectively. Furthermore, the MIS/PNP sensor exhibited good stability with adequate reproducibility and accuracy. / No presente trabalho é descrito o desenvolvimento de um sensor eletroquímico altamente sensível e seletivo baseado na tecnolgia dos Polímeros Impresso Molecularmente para detecção de 4-nitrofenol. Um eletrodo de carbono vítreo foi modificado com viniltrimetoxisilano (VTMS) e nanotubos de carbono de pardes múltiplas (MWCNT). O nanocompósito de carbono introduzido aumentou a área superficial e os locais ativos para transferência de elétrons. No método sol-gel quando um sillano é usado na síntese, é denominado MIS (Molecular Imprinted Silane) e NIS (non-imprinted Silane) quando o analito não está na síntese. Para a caracterização dos filmes de silanos utilizou - se a microscopia eletrônica de varredura (MEV), a análise termogravimétrica (TGA) e a espectroscopia de infravermelho por transformação de Fourier (FTIR). Este sensor apresentou o seu melhor desempenho em solução tampão fosfato 0,1 mol L-1, a pH 7,0. Depois de otimizado as condições operacionais, este sensor proporcionou uma faixa de resposta linear para o 4-nitrofenol de 0,1 a 100 μmol L-1 e bons parâmetros como limite de detecção, quantificação e sensibilidade de 0,03 μmol L-1, 0,1 μmol L-1 e 1,4×10-2 A mol L-1 respectivamente. Além disso, o sensor MIS/4-nitrofenol apresentou boa estabilidade com reprodutibilidade e precisão adequadas.
7

SENSOR AMPEROMÉTRICO A BASE DE UM POLÍMERO DE IMPRESSÃO MOLECULAR COM PROTOPORFIRINA IX DE FERRO PARA A DETERMINAÇÃO DE 4-AMINOFENOL / AMPEROMETRIC SENSOR BASE OF AN IMPRESSION OF POLYMER MOLECULAR PROTOPORPHYRIN IX WITH IRON FOR THE DETERMINATION OF 4-AMINOPHENOL

Martins Neto, José de Ribamar 15 January 2010 (has links)
Made available in DSpace on 2016-08-19T12:56:34Z (GMT). No. of bitstreams: 1 Jose de Ribamar Martins Neto.pdf: 683212 bytes, checksum: dd95cedfe01600e58259c96b38a5f571 (MD5) Previous issue date: 2010-01-15 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This work presents an analytical study on determination of 4-aminophenol (4-APh) with a system based on molecurlaly imprinted polymer (MIP) and iron protoporphyrin IX as biomimetic sensor of the peroxidase enzyme. The MIP synthesis was performed by the precipitation method and the analytical determinations by amperometric measurements with a glassy carbon electrode modified with the biomimetic system. The best analytical conditions established for 4-APh determination were: applied potential of -0.1 V vs. Ag/Agl, 0.05 mol L-1 Tris buffer solution, pH 7 and hydrogen peroxide concentration of 100 μmol L-1. Under such optimized conditions, a good linear sensor response was observed in a concentration range from 10 to 90 μmol L-1 (r>0.998), with detection and quantification limits of 3 and 10 μmol L-1, respectively. Experiments performed with tap and river water samples spiked with 4-APh resulted in 93 to 112 % recovery values, suggesting the viability of using the MIP/iron protoporphyrin IX system as biomimetic sensor for determinations of 4-APh in real samples. / O presente trabalho apresenta um estudo analítico da determinação de 4-aminofenol com um sistema a base de um polímero de impressão molecular (MIP, do inglês Molecularly Imprinted Polymer) e protoporfirina IX de ferro como sensor biomimético da enzima peroxidase. A síntese do MIP foi realizada pelo método de precipitação e as determinações analíticas realizadas amperometricamente com um eletrodo de carbono vítreo modificado com o sistema biomimético. As melhores condições analíticas estabelecidas para a determinação de 4-aminofenol foram: potencial aplicado de - 0,1V vs Ag/AgCl, tampão Tris 0,05 mol L-1, pH 7,0 e concentração de peróxido de 100 μmol L-1. Sob tais condições, uma boa resposta linear do sensor foi observada numa faixa de concentração de 10 a 90 μmol L-1 (r>0,9978), com limites de detecção e de quantificação de 3 e de 10 μmol L-1, respectivamente Experimentos realizados com amostras de águas de torneira e de rio fortificadas com 4-aminofenol, resultaram em valores de recuperação entre 93 a 112 %, indicando a viabilidade da aplicação do sistema MIP/proptoporfirina IX de ferro como sensor amperométrico para a detecção de 4-aminofenol em amostras reais.
8

Degradação de profenofós em solução aquosa e em ervilhas processadas por feixe de elétrons e a síntese de polímeros impressos para extração seletiva desse pesticida / Degradation of profenofos in aqueous solution and peas by electron beam processed and synthesis of imprinted polymers for selective extraction of this pesticide

Flavio Thihara Rodrigues 10 April 2015 (has links)
Profenofós é um organofosforado empregado como inseticida e acaricida amplamente utilizado no Brasil para o controle de pragas de cebolas, milho, soja, café, tomate, algodão, feijão, batata e outros. A irradiação é um processo empregado em todo o mundo e recomendada por diversos órgãos de saúde para a conservação de alimentos. A radiação ionizante utiliza raios gama, raios X ou aceleradores de elétrons e tem sido aplicada para eliminar ou reduzir a ação de agentes patogênicos e contribuir para aumentar o tempo de estocagem de vários alimentos. Os objetivos desse trabalho foram: (a) avaliar a degradação de soluções aquosas de profenofós submetidas à radiação ionizante, identificar e quantificar a formação de novos produtos por GC-MS; (b) analisar o efeito de feixe de elétrons em ervilhas inoculadas com soluções aquosas de profenofós; (c) sintetizar Polímeros Molecularmente Impressos (MIP) e Sílica Impressa Molecularmente (MIS), posteriormente, caracterizar os adsorventes em fase sólida e verificar sua seletividade para profenofós. O tratamento com aceleradores de elétrons com dose 31,6 kGy promoveu a formação de um novo produto de degradação e redução de 93,40 % de profenofós em soluções aquosas. Em ervilhas inoculadas com 1 &mu;g de profenofós submetidas à radiação ionizante de 30,4 kGy promoveu uma redução na concentração de profenofós em 57,46 %. Além disso, foram realizadas sínteses de MIP e MIS para a extração em fase sólida de profenofós. Os MIS sintetizados por sol-gel mostraram-se eficazes para o reconhecimento molecular e extração seletiva de profenofós. / Profenofos is an organophosphate widely used in Brazil as insecticide and acaricide in the control of pests in onions, corn, soybeans, coffee, tomato, cotton, beans, potatoes among others. Irradiation is a process used worldwide and recommended by many health agencies for food preservation. Food irradiation preserving process uses accelerated electrons, gamma rays or X-rays. Ionizing radiation treatment is applied to eliminate or to reduce the action of pathogens and to increase the shelf life of some foods. The objective of this study were (a) to evaluate the degradation of aqueous solutions of Profenofos by ionizing radiation, identify and quantify the formation of new products by GC-MS; (b) to analyze the effects of electron beam in peas inoculated with aqueous solutions of Profenofos; (c) to synthesize Molecularly Imprinted Polymer (MIP) and Molecularly Imprinted Silica (MIS), subsequently characterize the adsorbents in solid phase and check its selectivity for profenofos. The treatment with electron accelerators with 31.6 kGy dose promoted the formation of a new by-product and 93.40 % reduction of profenofos in aqueous solutions. In peas inoculated with 1 &mu;g of profenofos by ionizing radiation of 30.4 kGy promoted a reduction of 57.46 % in the concentration of profenofos. Furthermore, the MIP and MIS were performed for solid phase extraction of profenofos. The MIS synthesized by sol-gel proved to be effective for the recognition molecular and selective extraction of profenofos.
9

Degradação de profenofós em solução aquosa e em ervilhas processadas por feixe de elétrons e a síntese de polímeros impressos para extração seletiva desse pesticida / Degradation of profenofos in aqueous solution and peas by electron beam processed and synthesis of imprinted polymers for selective extraction of this pesticide

Rodrigues, Flavio Thihara 10 April 2015 (has links)
Profenofós é um organofosforado empregado como inseticida e acaricida amplamente utilizado no Brasil para o controle de pragas de cebolas, milho, soja, café, tomate, algodão, feijão, batata e outros. A irradiação é um processo empregado em todo o mundo e recomendada por diversos órgãos de saúde para a conservação de alimentos. A radiação ionizante utiliza raios gama, raios X ou aceleradores de elétrons e tem sido aplicada para eliminar ou reduzir a ação de agentes patogênicos e contribuir para aumentar o tempo de estocagem de vários alimentos. Os objetivos desse trabalho foram: (a) avaliar a degradação de soluções aquosas de profenofós submetidas à radiação ionizante, identificar e quantificar a formação de novos produtos por GC-MS; (b) analisar o efeito de feixe de elétrons em ervilhas inoculadas com soluções aquosas de profenofós; (c) sintetizar Polímeros Molecularmente Impressos (MIP) e Sílica Impressa Molecularmente (MIS), posteriormente, caracterizar os adsorventes em fase sólida e verificar sua seletividade para profenofós. O tratamento com aceleradores de elétrons com dose 31,6 kGy promoveu a formação de um novo produto de degradação e redução de 93,40 % de profenofós em soluções aquosas. Em ervilhas inoculadas com 1 &mu;g de profenofós submetidas à radiação ionizante de 30,4 kGy promoveu uma redução na concentração de profenofós em 57,46 %. Além disso, foram realizadas sínteses de MIP e MIS para a extração em fase sólida de profenofós. Os MIS sintetizados por sol-gel mostraram-se eficazes para o reconhecimento molecular e extração seletiva de profenofós. / Profenofos is an organophosphate widely used in Brazil as insecticide and acaricide in the control of pests in onions, corn, soybeans, coffee, tomato, cotton, beans, potatoes among others. Irradiation is a process used worldwide and recommended by many health agencies for food preservation. Food irradiation preserving process uses accelerated electrons, gamma rays or X-rays. Ionizing radiation treatment is applied to eliminate or to reduce the action of pathogens and to increase the shelf life of some foods. The objective of this study were (a) to evaluate the degradation of aqueous solutions of Profenofos by ionizing radiation, identify and quantify the formation of new products by GC-MS; (b) to analyze the effects of electron beam in peas inoculated with aqueous solutions of Profenofos; (c) to synthesize Molecularly Imprinted Polymer (MIP) and Molecularly Imprinted Silica (MIS), subsequently characterize the adsorbents in solid phase and check its selectivity for profenofos. The treatment with electron accelerators with 31.6 kGy dose promoted the formation of a new by-product and 93.40 % reduction of profenofos in aqueous solutions. In peas inoculated with 1 &mu;g of profenofos by ionizing radiation of 30.4 kGy promoted a reduction of 57.46 % in the concentration of profenofos. Furthermore, the MIP and MIS were performed for solid phase extraction of profenofos. The MIS synthesized by sol-gel proved to be effective for the recognition molecular and selective extraction of profenofos.

Page generated in 0.125 seconds