• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 504
  • 11
  • 11
  • 11
  • 9
  • 8
  • 8
  • 2
  • 2
  • 1
  • Tagged with
  • 526
  • 181
  • 127
  • 124
  • 75
  • 64
  • 60
  • 59
  • 55
  • 53
  • 52
  • 49
  • 47
  • 46
  • 46
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
191

Novo recipiente para processamento radiográfico manual = uma alternativa para a economia de soluções e preservação do meio ambiente / New container for manual radiographic processing : an alternatitve to save chemical solutions and preserve of the environmet

Eid, Nayene Leocádia Manzutti 06 September 2010 (has links)
Orientador: Li Li Min / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-16T04:54:04Z (GMT). No. of bitstreams: 1 Eid_NayeneLeocadiaManzutti_D.pdf: 3371365 bytes, checksum: c5958487d4a3f2d1c58e3f284b78b334 (MD5) Previous issue date: 2010 / Resumo: Embora o avanço tecnológico tenha viabilizado o uso dos sistemas digitais para a aquisição de imagens radiográficas, ainda hoje, no Brasil, os filmes radiográficos convencionais continuam sendo os tipos de receptores mais utilizados nos consultórios odontológicos. Deste modo, após a exposição aos raios X, os filmes radiográficos devem ser processados em soluções químicas a fim de que a imagem latente seja convertida em imagem real, passível de análise para diagnóstico. Sabe-se que, tanto o revelador quanto o fixador radiográfico contém em sua composição substâncias químicas altamente tóxicas, podendo apresentar risco à saúde de profissionais, que podem desenvolver lesões cutâneas e dermatites em decorrência do manuseio e manipulação destas soluções de processamento, além de apresentarem risco à saúde pública, caso ocorra a ingestão de produtos oriundos do meio ambiente previamente contaminado e ainda, sérios prejuízos ao meio ambiente, contaminação da fauna e flora, em virtude do descarte indevido destas soluções após seu uso. Tendo isto em vista, os objetivos deste trabalho foram: 1) Avaliar a eficácia de um novo modelo de recipiente para processamento radiográfico manual em câmara-escura portátil, para uso em consultórios odontológicos; 2) Avaliar qualitativamente e quantitativamente as imagens radiográficas obtidas por meio do processamento radiográfico nos diferentes recipientes; 3) Comparar os resultados obtidos em ambas as análises; sob a hipótese de que, devido às suas configurações geométricas, este novo modelo de recipiente propiciaria a economia de soluções químicas para que a execução do processamento radiográfico manual, reduziria os custos aos profissionais da área odontológica e, além disto, promoveria a redução do impacto ambiental devido à minimização da quantidade de químicos usados nestes recipientes. Para atender aos objetivos e conhecer sobre a aplicabilidade deste trabalho, realizou-se um outro estudo no qual se fez uma investigação sobre o descarte dos Resíduos de Serviço de Saúde produzidos em consultórios odontológicos localizados no Estado do Tocantins, Brasil. O estudo abordou aspectos relacionados ao conhecimento e atitudes dos cirurgiões dentistas frente aos resíduos gerados em seu ambiente de trabalho, e sua percepção sobre os resíduos gerados nos demais consultórios odontológicos. Um questionário foi aplicado a 239 cirurgiões-dentistas. Destes, 78,2% trabalhavam em clínica particular e 68,6% já haviam cursado alguma pós-graduação. Do total dos entrevistados, 87,9% afirmaram realizar exames radiográficos em seu consultório e estes foram unânimes em afirmar que o processamento das imagens era realizado manualmente em câmara-escura portátil e a maioria dos entrevistados (88,1%) afirmou que, em média, a cada 5 dias, descartava no esgoto as soluções químicas de processamento utilizadas. Ademais, 30,1% dos participantes acreditavam que os resíduos de amálgama eram descartados, por outros profissionais, em lixo comum e outros 8,8% supunham que o descarte era feito na pia dos consultórios; 61,9% acreditavam que o lixo contaminado (infectante) era disposto juntamente com o lixo comum e, em relação os resíduos perfurocortantes, 14,2% acreditavam que eram descartados em recipientes plásticos e 9,2% em lixo comum. Por meio deste trabalho, concluiu-se, que, em geral, os cirurgiões-dentistas entrevistados desconheciam sobre o correto descarte dos resíduos de serviço de saúde, uma vez que foi observada negligência desta prática por muitos deles, além da percepção de que outros profissionais também realizavam o descarte incorreto dos resíduos gerados em seu ambiente de trabalho. De posse destas informações, testou-se um novo modelo de recipiente para processamento radiográfico manual. Foram obtidas imagens radiográficas dos dentes posteriores de um phantom de mandíbula humana macerada e em seguida, estas imagens foram processadas em quatro câmaras-escuras portáteis. Em uma delas foram colocados dois recipientes convencionais (R1) abastecidos com 200ml das soluções de processamento e, em cada uma das demais câmaras-escuras, para este mesmo propósito, foi disposto um par de cada um dos três tipos de recipientes desenvolvidos pelos autores, R2, R3 e R4, abastecidos com 12, 19,2 e 24ml das soluções reveladora e fixadora respectivamente. Foram processadas 184 películas em R1, 40 em R2, 48 em R3 e 56 em R4. As películas radiográficas foram digitalizadas e posteriormente submetidas à análise objetiva no programa MaZda; em seguida, foram dispostas de maneira ordenadas, obedecendo a sequência do processamento, em papel cartão preto, para que pudessem ser submetidas à análise subjetiva. Os resultados da análise subjetiva mostraram que houve concordância dentre os cinco examinadores em relação às imagens consideradas aceitáveis para diagnóstico para os quatro recipientes estudados, e os resultados da análise objetiva mostraram que as imagens foram consideradas satisfatórias para diagnóstico até o 15º dia de pesquisa para R1, até o 4º dia para R2 e R3, e 5º dia para R4. A análise subjetiva mostrou-se menos sensível que a objetiva na avaliação da qualidade das imagens radiográficas processadas nos recipientes convencionais (R1), porém, mostrou grande correlação com a objetiva na avaliação da qualidade das imagens processadas nos demais recipientes (R2, R3 e R4). Deste modo, concluiu-se que o novo modelo de recipiente viabilizou o processamento de películas radiográficas em câmara-escura portátil, utilizando menor quantidade de soluções químicas para o processamento radiográfico manual, sendo que estas se apresentaram com qualidade satisfatória para diagnóstico. / Abstract: Even though the technological advances have allowed the utilization of digital systems for acquisition of radiographic images, conventional radiographic films are still the most used in dental offices in Brazil. Thus, after X-ray exposure, the radiographic films must be processed in chemical solutions to change the latent stored images into visible images for diagnostic purposes. Both the developer and fixer contain highly toxic chemical substances that may endanger the health of professionals, who may present skin lesions and dermatitis due to handling of these solutions. These chemicals may also constitute a public health problem if contaminated products of the environment are ingested, besides posing serious risks to the environment by contamination of the fauna and flora if these chemical solutions are improperly discarded after utilization. Therefore, this study aimed to: 1) evaluate the efficacy of a new container for manual radiographic processing in portable darkrooms for utilization in dental offices; 2) qualitatively and quantitatively evaluate the radiographic images obtained by radiographic processing in the different containers; 3) compare the results obtained in both analyses, considering that the design of the new container would allow dental professionals to save the chemical solutions used for manual radiographic processing, reducing the costs and also the environmental impact, considering the minimization of the quantity of chemical solutions used in these containers. To meet these objectives and know the applicability of this study, a previous study was conducted in which we investigated the discard of Health Service Wastes produced in dental offices of the state of Tocantins, Brazil. The study discussed the aspects related to the knowledge, perception and attitudes of dentists towards the waste generated in their work environment. We interviewed 239 dentists using a structured questionnaire, of whom 78.2% worked at private offices and 68.6% had post-graduate degree. From the total of respondents, 87.9% stated that they did perform intraoral radiographic exams in their offices, and these professionals unanimously used portable dark rooms from commercial brands for radiographic processing. Most dentists (88.1%) that perform radiographic exams in their offices declared that the mean period for changing the radiographic processing chemicals was 5 days. Conversely, 30.1% of participants believed that amalgam wastes were discarded in common garbage, and 8.8% believed that amalgam wastes were discarded in the offices' sink; 61.9% of them believed that the infectious waste were discarded together with the common garbage. Regarding the sharp objects, 14.2% believed that these were discard in plastic recipients, and 9.2% believed that the majority of dentists discarded sharp objects in the common garbage. The data obtained in this study revealed that, in general, the dentists interviewed were unaware of the correct procedures for the discard of health service waste, since there was both negligence in these practices by many of them and the perception that other professionals also performed incorrect discard of waste generated in their work environment. After achievement of these data, a new model of container for manual radiographic processing was tested. Radiographic images were obtained from the posterior teeth of a phantom dry human mandible and processed in four portable darkrooms. One darkroom had two conventional containers (R1) filled with 200ml of processing solutions. For the same purpose, each of the other darkrooms had one pair of the three types of containers designed by the authors, namely R2, R3 and R4, filled with 12, 19.2 and 24ml of developing and fixer solutions. A total of 184 films were processed in R1, 40 in R2, 48 in R3 and 56 in R4. The films were digitized and objectively analyzed using the software MaZda; following, they were arranged according to the sequence of processing in black cardboards for subjective analysis. The results of the subjective analysis revealed good agreement between the five examiners concerning the images considered acceptable for diagnosis for all four containers investigated. The results of the objective analysis demonstrated that the images were considered satisfactory for diagnosis until the 15th day of investigation for R1, fourth day for R2 and R3, and fifth day for R4. The subjective analysis was less sensitive than the objective analysis to evaluate the quality of radiographic images processed in the conventional containers (R1), yet presented high correlation with the objective analysis for evaluation of the quality of images processed in the other containers (R2, R3 and R4). Thus, it was concluded that the new model of container allowed processing of radiographic films in portable darkrooms using a smaller quantity of chemical solutions for manual radiographic processing and presenting satisfactory quality for diagnosis. / Doutorado / Neurocirugia / Doutor em Fisiopatologia Medica
192

DeterminaÃÃo de Micropoluentes Emergentes em Esgoto SanitÃrio, Hospitalar e Ãguas Superficiais / Determination of Emerging Micropollutants in Sewage, and Surface Water Hospital

Neyliane Costa de Souza 18 November 2011 (has links)
FundaÃÃo Cearense de Apoio ao Desenvolvimento Cientifico e TecnolÃgico / No Brasil, estudos de avaliaÃÃo de micropoluentes emergentes em matrizes ambientais como esgotos sanitÃrios e hospitalares, e corpos de Ãgua, ainda sÃo bastante incipientes, assim como a remoÃÃo desses compostos em EstaÃÃes de Tratamento de Esgotos (ETEs) de baixo custo como lagoas de estabilizaÃÃo, assim como em sistemas de lodos ativados e sistemas anaerÃbio-aerÃbio compactos. O presente trabalho teve como objetivo geral investigar a presenÃa de micropoluentes em matrizes ambientais como esgotos sanitÃrios e hospitalares, e Ãgua superficial, avaliar a remoÃÃo destes compostos em ETEs de baixo custo e aplicar o processo de oxidaÃÃo avanÃada (POA) UV/H2O2 como opÃÃo de pÃs-tratamento. Os principais micropoluentes emergentes estudados foram: 2,4,6-triclorofenol, pentaclorofenol, cafeÃna (CAF), dipirona (DIP), diclofenaco de sÃdio (DCF), bis (2-etil-hexil) ftalato (DEHP), estrona (E1), 17β-estradiol (E2), β-estradiol 17-acetato (EA2), 17α-etinilestradiol (EE2) e colesterol (COL). As amostras foram coletadas em ETEs localizadas em Fortaleza e em sua regiÃo metropolitana. Os corpos receptores investigados foram o Rio Maranguapinho e o Riacho Paupina. Para a prÃ-concentraÃÃo dos micropoluentes utilizou-se extraÃÃo em fase sÃlida (SPE) com cartuchos C-18 e extraÃÃo lÃquido-lÃquido (ELL). A SPE foi a tÃcnica mais eficiente na concentraÃÃo da maioria dos micropoluentes emergentes, e a ELL se mostrou a melhor tÃcnica para compostos organoclorados. Foram realizados estudos de otimizaÃÃo das condiÃÃes de detecÃÃo dos compostos pelo uso de tÃcnicas de cromatografia gasosa acoplada à espectrometria de massas (GC/MS). Foram identificados compostos farmacÃuticos e desreguladores endÃcrinos em todas as amostras de esgotos com as seguintes faixas de concentraÃÃes efluentes: CAF (3,0-15,8 μg/L), DIP (0,3 μg/L), DCF (1,9 μg/L), DEHP (0,01-8,5μg/L), E1 (0,04-1,7 μg/L), E2 (0,03-4,0 μg/L), EA2 (0,14-9,3 μg/L), EE2 (1,0 μg/L) e COL (0,01-6,2 μg/L). Nos dois corpos receptores estudados (Rio Maranguapinho e Riacho Paupina) foram identificados desreguladores endÃcrinos. Os tratamentos realizados pelas ETEs nÃo foram suficientes para remoÃÃo total de todos os micropoluentes estudados, no entanto, a eficiÃncia para a maioria dos compostos foi acima de 50%. Em se tratando da avaliaÃÃo em sistemas de lagoas de estabilizaÃÃo, o estudo revelou boas eficiÃncias de remoÃÃo em sistemas constituÃdos de lagoa anaerÃbia seguida de facultativa e de maturaÃÃo, sendo os menores valores de remoÃÃo alcanÃados quando uma Ãnica lagoa facultativa primÃria estava presente. A avaliaÃÃo do uso do POA por meio do planejamento fatorial multivariado revelou que as melhores condiÃÃes para remoÃÃo de micropoluentes emergentes foram pH Ãcido (pH 3), concentraÃÃo de perÃxido de hidrogÃnio acima de 400 mg/L e tempos de detenÃÃo hidrÃulica no reator acima de 50min. / In Brazil, studies evaluating emerging micropollutants in environmental matrices such as sewage and hospital wastewater, as well as surface waters, are still quite incipient as well as the removal of these compounds in low cost Wastewater Treatment Plants (WWTPs) such as stabilization ponds, as well as in activated sludge systems or anaerobic/aerobic compact systems. This work aimed to investigate the presence of micropollutants in environmental matrices such as sewage and hospital wastewaters, and in surface waters. Additionally, this study evaluated the removal of these compounds in low-cost WWTPs and studied the advanced oxidation process (AOP) â UV/H2O2 â as a post-treatment option. The main emerging micropollutants studied were: 2,4,6-trichlorophenol, pentachlorophenol, caffeine (CAF), dipyrone (DIP), sodium diclofenac (DCF), bis (2-ethylhexyl) phthalate (DEHP), estrone (E1), 17β-estradiol (E2), estradiol acetate (EA2), 17α-ethinyl estradiol (EE2) and cholesterol (CHO). The samples were collected from WWTPs located in Fortaleza and its metropolitan region. The receiving surface waters investigated were: Maranguapinho River and Paupina Creek. For the pre-concentration studies of micropollutants, solid phase extraction (SPE) with C-18 cartridges was used, as well as the liquid-liquid extraction (LLE) method. The SPE technique was the most efficient method in concentrating the majority of emerging micropollutants, and the LLE proved to be the best technique for organochlorine compounds. Optimization studies were performed to detect the ideal conditions to determine the compounds by using gas chromatography (GC) and gas chromatography-mass spectrometry (GC/MS) techniques. In all wastewater samples pharmaceuticals and endocrine disrupting compounds were identified, and the range of effluent concentrations were: CAF (3.0-15.8 μg/L), DIP (0.3 μg/L), DCF (1.9 μg/L), DEHP (0.01-8.5μg/L), E1 (0.04-1.7 μg/L), E2 (0.03-4.0 μg/L), EA2 (0.14-9.3 μg/L), EE2 (1.0 μg/L) and CHO (0.01-6.2 μg/L). Endocrine disrupting compounds were identified in the Maranguapinho River and Paupina Creek. The wastewater treatment in the WWTPs was not enough for the complete removal of all micropollutants studied; however, the efficiency level for most of compounds was above 50%. Regarding the evaluation in stabilization ponds systems, the study revealed good removal of micropollutants in systems composed of anaerobic pond followed by facultative and maturation ponds, in which the lowest efficiency levels were verified when a single facultative pond was present. The evaluation of the AOP as a post-treatment option by multivariate factorial design showed that the optimal conditions for the removal of emerging micropollutants were acidic pH (pH 3), hydrogen peroxide concentration above 400 mg/L and hydraulic retention times in the reactor above 50 minutes.
193

Effects of aquatic contaminants on the habitat selection and spatial distribution in fish: a complementary approach to traditional ecotoxicological tests / Efeitos de poluentes aquáticos na seleção de hábitat e distribuição espacial em peixes: uma abordagem complementar aos testes ecotoxicológicos tradicionais

Silva, Daniel Clemente Vieira Rêgo da 04 December 2017 (has links)
Conventional ecotoxicological tests (forced exposure) are an important tool when what is sought are the possible acute and chronic effects of environmental pollutants on each individual that is exposed. The disadvantage of this approach lies in the fact that the organisms are kept enclosed within containers of the same concentration for several hours and / or days. The forced exposure test has no ecological relevance when the modeled environment exhibits a contamination gradient and organisms can move along this gradient. In many aquatic ecosystems, it is common to observe a contamination gradient, with concentrations decreasing with distance from the discharge zone, so that organisms do not necessarily exhibit continuous and forced exposure to the contaminant. The objective of this work was to analyze how aquatic pollutants (e.g Triclosan, Bisphenol, Atrazine and Copper) influence the dispersion / habitat selection pattern of two species of fish: Poecilia reticulata and Danio rerio, using a static system (non-forced exposure) with several compartments, forming a gradient of contamination with the compound to be analyzed. All pollutants tested triggered an avoidance response in fish at environmentally relevant concentrations. The concentrations that caused avoidance on the organisms are lower than those that cause sub-lethal effects on aquatic organisms, including fish. We also find in one of our approaches the potential for the formation of a chemical barrier (habitat fragmentation) by the release of pollutants into the water bodies, reducing the migration potential of aquatic organisms. Finally, one of the most important findings is the interaction of the species with each other when exposed to a pollution gradient. In this case, the presence of one species interfered in the distribution of the other (reduction of the migration potential), when both were in the same system. Thus, the non-forced approach demonstrates to be a powerful tool in the evaluation of environmental risk, complementary to the traditional ecotoxicological tests / Os testes ecotoxicológicos convencionais (exposição forçada) são uma ferramenta importante quando o que se busca são os possíveis efeitos agudos e crônicos dos poluentes ambientais sobre cada indvíduo que é exposto. A desvantagem dessa abordagem está no fato de que os organismos são mantidos enclausurados dentro de recipientes com uma mesma concentração por várias horas e/ou dias. O teste de exposição forçada não tem relevância ecológica quando o ambiente modelado apresenta um gradiente de contaminação e os organismos podem se mover ao longo deste gradiente. Em muitos ecossistemas aquáticos, é comum observar um gradiente de contaminação, com as concentrações diminuindo com a distância da zona de descarga, de modo que os organismos não apresentam obrigatoriamente uma exposição contínua e forçada ao contaminante. Desta forma, este trabalho teve como objetivo a análise de como os poluentes aquáticos (e.g. Triclosan, Bisfenol, Atrazina e Cobre) influenciam o padrão de dispersão / seleção de habitat por duas espécies de peixes: Poecilia reticulate e Danio rerio, utilizando um sistema estático (não forçado) com vários compartimentos, formando um gradiente de contaminação com o composto a ser analisado. Todos os poluentes testados dispararam uma resposta de fuga nos peixes em concentrações ambientalmente relevantes. As concentrações que causaram a fuga dos organismos são menores do que aquelas que causam efeitos sub-letais em organismos aquáticos, incluindo peixes. Encontramos também em uma de nossas abordagens o potencial de formação de uma barreira quimica (fragmentação de habitat) pela liberação de poluentes nos corpos hídricos, reduzindo o potencial de migração dos organismos aquáticos. Por fim, um dos achados mais importantes está na interação das espécies entre si quando expostas a um gradiente de poluição. Nesse caso, a presença de uma espécie interferiu na distribuição da outra (redução do potencial de migração), quando ambas se encontravam no mesmo sistema. Sendo assim, a abordagem não forçada demonstra ser uma ferramenta poderosa na avaliação de risco ambiental, complementar aos testes ecotoxicológicos tradicionais
194

Investigação das propriedades elétricas, ópticas e eletroquímicas de filmes finos semicondutores de BiVO4 e NiO para aplicação em fotoeletrocatálise /

Silva, Marcelo Rodrigues da. January 2012 (has links)
Orientador: Luíz Vicente de Andrade Scalvi / Banca: Valmor Roberto Mastelaro / Banca: Joelma Perez / Banca: Fenelon Martinho Lima Pontes / Banca: Luiz Henrique Dall'Antonia / Resumo: Os semicondutores BiVO4 e NiO vem sendo bastante estudados nos últimos anos para aplicação em fotoeletrocálise, mais especificamente na degradação de poluentes orgânicos em meio aquoso, implicando em sustentabilidade ambiental. Neste trabalho, estes materiais foram obtidos na forma de filmes finos pelas técnicas: Síntese de Combustão em Solução e Co-precipatação, combinadas ao processo de deposição via molhamento (dip-coating). A composição, microestrutura e morfologia dos filmes foram avaliadas por TG-DTA, DTX e MEV. Os resultados de TG-DTA e DRX permitiram verificar a temperatura de formação das classes desejadas, 287ºC para o BiVO4 e 305ºC NiO. Imagens MEV mostram que os filmes são compostos por partículas de formato aproximadamente eférico, com boa dispersão sobre o suporte. Espectros UV-VIS mostraram que filmes de BiVO4 absorvem na região do visível com bandgap da ordem de 2,5 eV, e filmes de NiO absorvem no ultravioleta no ultravioleta com bandgap da ordem de 3,0 eV. A caracterização elétrica, trouxe resultados surpreendentes, particularmente no filme de NiO, onde iluminação com luz de energia acima do gap aumentou a resistividade do material, o que está ligado a variâncias de Ni2+. A caracterização eletroquímica, realizada por voltametria cíclica e cronoamperometria, mostrou que ambos os filmes respondem à excitação à excitação com luz de determinado comprimento de onda, além de apresentar estabilidade na corrente fotogerada. Ambos os filmes se mostraram eletroativos frente à reação de degradação do azul de metileno, sendo que na presença de luz ocorre a maior degradação. Um eletrodo com heterojunção p-n foi confeccionado utilizando estes dois materiais. O eletrodo FTO/p-NiO/n-BiVO4 apresentou excelente desempenho frente à degradação do azul de metileno, em... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The semiconductor BiVO4 and NiO have been extensively studied in recent years for the photoelectrocatalysis application, more specifically in the organics polluants degradation in aqueous solution, which leads to sustainability environment. In this work, these materials were obtained in the form of thin films by Solution Combustion Systhesis and co-precipitation techniques, combinee with the dip-coating deposition process. The composition, microstructure and morphology of these films was evaluated by TG-DTA, XRD and SEM. TG-DTA and XRD results were important to verify the temperature of the desired phase formation, which tuned out as 287ºC and 305ºC for the BiVO4 and NiO, respectively. SEM images show that the films consist of spherical particles with good dispersion on the support . UV-VIS Spectroscopy, have shown that BiVO4 thin film absorbs in the viable region with bandage energy of about 2.5 eV, whereas the NiO thin film absorbs in the ultraviolet region with bandagap energy about 3.0 eV. The electrical characterization has shown striking results, particularly on the NiO film, where irradiation with above bandgap light leads to a resistivity increase, which was related to the presence of Ni2+ vacancies. The electrochemical characterization, carried out by cyclic voltammetry and chronoamperometry, has shown that both the films respond to excitation with light of specific wavelength and provides stability in the photocurrent. Both the films are electroactive in the methylene blue dedradation reaction and that the greatest degradation takes place in the presence of light. A p-n heterojunction electrode was made using these two materials. The FTO/p-NiO/n-BiVO4, electrode showed excellent performance in the methylene blue degradation in different electrolytes under visible and UV light ilumination. The percentages of... (Complete abstract click electronic access below) / Doutor
195

Efeitos da poluição atmosférica em marcadores inflamatórios pulmonares e sistêmicos de indivíduos submetidos ao exercício físico em ambiente aberto e fechado /

Coripio, Iris Cristina January 2019 (has links)
Orientador: Dionei Ramos / Resumo: Introdução: A poluição atmosférica é um assunto discutido mundialmente, causando um impacto na saúde humana e se tornando um grave problema de saúde pública, condições meteorológicas como temperatura, e umidade relativa do ar, também podem influenciar na magnitude dos efeitos adversos da poluição atmosférica na saúde humana.Objetivo:Verificar impactos da exposição aos poluentes atmosféricos sobre internações hospitalares por doenças cardiovasculares em uma população adulta, e o efeito da realização de exercício aeróbico em ambiente aberto e fechado com diferentes concentrações de MP2,5, temperatura e umidade relativa do ar na toxicidade pulmonar de indivíduos sedentários e ativos.Métodos: Registros de internações hospitalares por doenças cardiovasculares captados a partir da base de dados referentes ao sistema único de saúde no período de janeiro de 2014 a dezembro de 2015. Níveis de MP10, NO2, temperatura e umidade relativa foram registrados. No segundo estudo foram avaliados 27 indivíduos, divididos em dois grupos: ativos e sedentários submetidos a um exercício aeróbico em ambiente aberto e fechado. Níveis séricos de CC16, monóxido de carbono no ar exalado (COex), e parâmetros hemodinâmicos foram coletados antes e após a prática da atividade, concentrações de MP2,5, temperatura e umidade relativa do ar foram mensurados durante todo exercício. O nível de significância foi considerado p<0,05. Conclusões: Foi concluído que o impacto da exposição aos poluentes atmosféricos, pri... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Introduction: Air pollution is a subject discussed world wide, inducing an impact on human health and becoming a severe public health problem, weather conditions such as temperature and relative humidity can also influence the magnitude of the adverse effects of air pollution on human health. Objective: To verify the impact of exposure to air pollutants on hospital admissions due to cardiovascular diseases in an adult population and the effect of aerobic exercise in outdoor and indoor ambient with different concentrations of PM2.5, temperature and relative air humidity in pulmonary toxicity of sedentary and active individuals. Methods: Records of hospital admissions for cardiovascular diseases collected from Brazilian Unified Health System (SUS) database from January 2014 to December 2015. Levels of PM10, NO2, temperature and relative humidity were recorded. In the second study, 27 subjects were evaluated, splited into two groups: active and sedentary subjects submitted to an aerobic exercise in an outdoor and indoor ambient. Serum levels of CC16, carbon monoxide in the exhaled air (COex), and hemodynamic parameters were collected before and after the practice of the activity, concentrations of PM2.5, temperature and relative humidity were measured throughout the exercise. The significance level was considered p<0.05. Conclusions: It was concluded that the impact of exposure to air pollutants mainly PM10 on hospital admissions for cardiovascular diseases in adults, and PM2.5 ... (Complete abstract click electronic access below) / Mestre
196

Poluição atmosférica derivada de queimadas de cana-de-açúcar no estado de São Paulo / Air Pollution Derivate from Sugarcane Burning in Sao Paulo State

Silveira, Thiago Souza 12 September 2014 (has links)
O presente trabalho teve como objetivo a análise do transporte de poluentes atmosféricos gerados na queima da cana-de-açúcar no estado de São Paulo durante o ano de 2010, pois a cultura canavieira no estado é muito forte, abastecendo o mercado alimentício, energético e de bebidas. Porém, apresenta um grave problema com a queima da plantação antes da colheita, gerando poluição e enfraquecendo o argumento de energia limpa. Baseado nas teorias: dos Sistemas e dos Geossistemas, na dinâmica atmosférica e no uso de modelagem como instrumento de análise; além do levantamento dos dados atmosféricos e de poluição aferidos, mapeamento da área e das queimadas, concluiu-se que há áreas com picos de poluição ao longo do ano; a pluma de poluentes normalmente vai para outros estados como Minas Gerais e Mato Grosso do Sul e ocorreram eventos generalizados de queima de biomassa, principalmente entre agosto e setembro, porém com a mudança na direção do vento, geralmente quando está prestes a chegar uma frente fria, quando esses poluentes são direcionados para a Região Metropolitana de São Paulo e Campinas; confirmando a hipótese observando a distribuição e concentração de poluentes segundo os dados de circulação atmosférica e de poluição / This study has the objective to analyze the air pollution transport from sugarcane burn in Sao Paulo State in 2010, as the planted areas are very vast, it supplies the food, energy and beverage industry. By the other hand, it presents severe problem of burning culture before the harvest period, it causes air pollution and disqualify the clean energy argument. Based on the System and Geosystem theories, on atmospheric dynamic and using models as analysis instrument; in addiction getting atmospheric and pollution data observed, mapping sugarcane and the burned area, it was concluded there were parts with peaks of pollution during this year, the plume of pollutants normally are transported to other States as Minas Gerais and Mato Grosso do Sul and also there were several and generalized events of biomass burn principally in August and September, despite the wind change generally when it is upcoming a cold front, those pollutants are directed to Metropolitan Region of Sao Paulo and Campinas; confirming the hypothesis observing the concentration and distribution of them by the air circulation and pollutants data
197

Análise da fonte e composição da poluição atmosférica em diferentes locais da região metropolitana de São Paulo / Analysis of source and composition of air pollution in different locations in the Metropolitan Region of São Paulo

Ramires, Letícia Ogushi Romeiro 10 January 2013 (has links)
Grandes cidades, como São Paulo, são afetadas de forma significante pela poluição atmosférica. É de grande importância a caracterização das fontes emissoras da poluição atmosférica, não somente nas regiões centrais, mas também nas regiões periféricas, pois a composição da poluição pode não ser homogênea em toda a extensão da cidade. Neste estudo foram caracterizados os componentes da poluição atmosférica em quatro regiões dentro cidade de São Paulo. Para este fim foram Coletados Material Particulado (PM2.5) durante vinte dias no período de inverno de 2011 e vinte dias durante o período de verão de 2011. O material foi coletado através de filtros de policarbonato com 24 h de exposição, e foi submetido a análises gravimétricas, determinação da concentração de Black Carbon por refletância e determinação da composição elementar por Fluorescência de Raios-X. A identificação das diferentes fontes geradoras de material particulado foi baseada na análise de Componentes Principais (ACP). A variação da concentração da massa do material particulado fino (PM2.5) em g/m3 não teve diferença significativa entre os locais amostrados, mas mostrou diferença entre as estações do ano, sendo maior no período do inverno em todos os locais. A proporção do Black Carbon teve um comportamento diferente da massa. O Black Carbon não variou significantemente entre as estações do ano, porém apresentou diferença entre os locais amostrados, destacando-se no Parque do Ibirapuera e na Zona Leste. Foram encontrados 3 Fatores que explicam 75% da variabilidade. O Fator 1 é constituído pelos elementos Ti, V, Mn, Fe, Ni, Pb, P, S Cr e K e foi atribuído como sendo associado à ressuspensão de solo e emissões veiculares, O Fator 2 é composto por V, P, BC, e S e foi interpretado como sendo representativo de emissões veiculares de combustíveis com alto teor de enxofre. O Fator 3 é 7 associado aos elementos BC e Ni e foi interpretado como sendo produzido por emissões veiculares em geral / Large cities such as São Paulo are significantly affected by air pollution. It is of great importance to characterize the emission sources of air pollution, not only in the central regions of the city of São Paulo, but also in peripheral regions, do to the fact that the composition of pollution may not be homogeneous across the city area. This study shows the Characterized the components of air pollution in four different areas of the metropolitan region of São Paulo. Particulate matter (PM 2.5) was collected during the winter of 2011 and summer of 2011. It was collected 24-h PM2.5 samples, employing gravimetry to determine PM2.5 mass concentrations; reflectance to quantify black carbon concentrations and X-ray fluorescence to characterize elemental composition. A receiver model based on principal component analysis (PCA) was used to identify the involvement of the different sources for the generation of particulate matter. The fine particulate matter (PM2.5) in g/m3 did not differ significantly among the locations. However, the results collected showed differences according the seasons evaluation, being higher in the winter for all regions sampled. The proportion of Black Carbon behaves differently than the mass. It does not vary significantly between the seasons, but between the different regions. The proportion of Black Carbon was higher in Ibirapuera Park and the East Zone. Was found 3 factors explaining 75% of the variability. Factor 1 consists of the elements Ti, V, Mn, Fe, Ni, Pb, P, S Cr e K and was related to crustal emission (soil) and vehicle emissions, Factors 2 consists of the elements V, P, BC, e S and can be related to vehicular emissions of fuels with high sulfur content. Factor 3 consists of the elements BC and Ni was associated to vehicle emission
198

Efeitos da adição de O2 puro sobre as emissões poluentes produzidas na incineração industrial de resíduos perigosos / not available

Sindicic, Daniel Ricardo 25 March 2002 (has links)
Estudou-se o efeito da adição de oxigênio puro ao processo de incineração de resíduos industriais perigosos como meio de reduzir emissões poluentes para a atmosfera. Deu-se ênfase especial à emissão de Material Particulado (MP) pois este é freqüentemente o fator limitante dos processos de incineração e o mais difícil de controlar. O trabalho experimental foi desenvolvido em uma unidade industrial com fornalha rotativa, câmara de pós combustão e sistema de tratamento de gases. Foram utilizados percentuais de oxigênio na vazão de oxidante do resíduo variando de 21% (ar atmosférico) até 55% (ar com adição de O2). Os resíduos de teste, sólidos e líquidos, foram materiais e misturas de materiais escolhidos por apresentarem diferentes propriedades físicas e químicas. Os teores de cloro destes materiais foram de até 26%, o de nitrogênio até 6,5%, a umidade até 33,5% e o poder calorífico inferior variou entre 13,6 e 50,5 MJ/kg. Sais metálicos foram adicionados em testes especiais destinados à detecção deste tipo de emissão. Os resultados mostraram, para a maioria dos casos, redução expressiva na emissão de particulados, no volume de escórias e na emissão de gases ácidos. O tempo de combustão de uma carga típica caiu para 1/3 daquele obtido como o uso de ar atmosférico apenas. Por outro lado a emissão de NOx subiu, mas não ultrapassou o limite estabelecido pela legislação. A operação com a mistura de alto teor de cloro (26%) e nitrogênio (6,5%) mostrou comportamento diferente das demais, produzindo aumento da emissão de MP e gases ácidos, e acentuando a emissão de NOx. A maior emissão de MP parece decorrente da operação do sistema de tratamento de gases e não do processo de incineração em si. Um modelo matemático baseado em rede neural foi desenvolvido para a previsão das emissões de MP e NOx, mostrando resultados razoáveis para o número de testes disponíveis, 27 ao todo. No geral o processo mostrou-se exequível e técnica, econômica e ambientalmente atraente. / The addition of pure oxygen to a process of incineration of industrial hazardous wastes was investigated as a mean to reduce atmospheric pollutants. Special attention was given to the emission of particulate matter (PM), once this is often the lirniting and most difficult factor to control in the incineration processes. The experimental work was developed in an industrial plant comprised by a rotary kiln incinerator equipped with a post combustion chamber and a gas treatment system. Oxygen percentage in the waste oxidant flow was varied from 21% (atmospheric air) to 55% (air plus pure O2). The wastes, liquid and solid, were materiaIs and mixtures of materials specifically chosen to present a range of physical and chemical properties. In them chlorine content were up to 26%, nitrogen up to 6.5%, humidity up to 33.5% and net calorific value from 13.6 to 50.5 MJ/kg. Metallic saIts were added in tests designed to detect this kind of emission. The resuIts show for the majority of the tests an expressive reduction in the emissions of PM, bottom ash, and acid gases. The combustion time of a typical load was decreased to 1/3 of its usual value (atmospheric air) when O2 was added. On the other hand, emissions of NOx have increased, although they remained bellow legislation limits. The operation with a mixture containing high levels of chlorine (26%) and nitrogen (6.5%) showed a different behavior increasing PM and acid gases emissions and accentuating the NOx emissions. The increase in PM seems to be a resuIt of the cleaning gas plant operational characteristics, rather than of the incineration process itself. A mathematical model based on neural networks was developed to predict PM and NOx emissions, showing reasonable agreement with experimental data for the 27 tests carried out. In general the process showed to be feasible and technical, economical end environmentally attractive.
199

Estudo da influência do material particulado na incidência e mortalidade por câncer na cidade de São Paulo / The influence of particulate matter on the incidence and mortality cancer in São Paulo

Yanagi, Yoshio 19 October 2010 (has links)
Objetivo. Este trabalho teve como objetivo geral verificar a influência do poluente atmosférico material particulado inalável (MP10) na incidência e na mortalidade por câncer, na cidade de São Paulo. Métodos. Os dados de câncer foram coletados do Registro de Câncer de São Paulo e os dados do poluente provenientes da CETESB. Foram utilizadas técnicas estatísticas para verificar a relação do MP10 sobre a incidência e a mortalidade por câncer (pele, pulmão, laringe, tireóide, estômago, próstata, colo do útero, mama, bexiga, cólon, esôfago e reto), nos distritos do Brás, Santana, Moóca, Cambuci, Moema, Freguesia do Ó, Campo Belo, Lapa, Consolação, Santo Amaro e São Miguel. Os distritos também foram agrupados, de acordo com as concentrações de MP10, para orientar a expansão da rede de monitoramento do poluente na cidade de São Paulo. Resultados. Os resultados mostraram que, para alguns tipos de câncer (pele, pulmão, tireóide, laringe e bexiga), os coeficientes de correlação estatística ficaram entre 0,60 e 0,80, em alguns períodos, para a incidência. Para a mortalidade, o câncer de pulmão apresentou mais correlações neste intervalo. O agrupamento dos distritos permitiu a formação de quatro grupos distintos, o que possibilitaria, após estudo técnico, a redistribuição de alguma estação de monitoramento do segundo grupo para outras regiões da cidade, como leste ou sul. A Análise Espacial mostrou que distritos distantes do centro da cidade apresentaram risco relativo (RR) acima do esperado, dependendo do tipo de câncer. Conclusões. O estudo mostrou que o poluente atmosférico MP10 tem correlação alta com a incidência de alguns tipos de câncer (pele, pulmão, tireóide, laringe e bexiga) e com a mortalidade por câncer de pulmão, em alguns períodos, na cidade de São Paulo. A expansão da rede de monitoramento de MP10, na cidade de São Paulo, poderia ser direcionada às regiões leste ou sul / Objective. The general objective of this study was to verify the influence of pollutant inhalable particulate matter (PM10) on the incidence and cancer mortality in the city of São Paulo. Methods. The cancer data were collected from the Cancer Registry of São Paulo and pollutant data from the CETESB. Statistical techniques were used to investigate the relationship between PM10 and the incidence and mortality of cancer (skin, lung, larynx, thyroid, stomach, prostate, cervix, breast, bladder, colon, esophagus and rectum), in the districts of Brás, Santana, Moóca, Cambuci, Moema, Freguesia do Ó, Campo Belo, Lapa, Consolação, Santo Amaro and São Miguel. The districts were also grouped according to the concentrations of PM10, to guide the expansion of the pollutant monitoring network in São Paulo. Results. The results showed that for some types of cancer (skin, lung, thyroid, larynx and bladder), the statistical correlation coefficients were between 0.60 and 0.80, in some periods, for incidence. For mortality, lung cancer showed more correlations in this interval. The grouping of districts allowed the formation of four distinct groups, which would allow, after a technical study, the redistribution of any monitoring station in the second group to other parts of the city, like east or south. A Spatial Analysis showed that districts distant from the center presented a relative risk (RR) greater than expected, depending on the type of cancer. Conclusions. The study showed that air pollutant PM10 has high correlation with the incidence of some cancers (skin, lung, thyroid, larynx and bladder) and mortality from lung cancer in some periods, in São Paulo. The expansion of network monitoring PM10, in the city of São Paulo, could be targeted to areas east or south
200

Efeito da exposição in vitro à bifenila policlorada nº 126 em células 3T3-L1 / In vitro exposure effect of polychlorinated biphenyl n° 126.

Cruz, Wesley Soares 29 October 2015 (has links)
A bifenila policlorada n° 126 (3,3\',4,4\',5-Penta-cloro-bifenil, PCB126) é um poluente orgânico persistente (POP), tóxico para os seres vivos. Recentemente, a associação entre a exposição aos POPs e doenças metabólicas têm sido descrita. No entanto, os mecanismos desta toxicidade não estão esclarecidos. Desta forma, este trabalho visou elucidar os efeitos da exposição ao PCB126 sobre pré-adipócitos da linhagem 3T3-L1, diferenciados ou não, focando nos mecanismos de morte celular, proliferação, diferenciação e metabolismo. O PCB 126 foi diluído em DMSO (0,13%). Células 3T3-L1 foram mantidas em meio Dulbecco\'s modified Eagle\'s (DMEM, 5% de CO2 a 37ºC) e sua diferenciação foi realizada pela incubação com solução contendo coquetel adipogênico durante 10 dias. As células foram incubadas com diferentes concentrações de PCB126, DMSO (0,13%) ou DMEM. Células não diferenciadas foram empregadas em ensaios de viabilidade, morte, proliferação, ciclo celular, fragmentação do DNA (citometria de fluxo) e ensaios de produção de espécies reativas de oxigênio (ROS, espectrofotometria de fluorescência). Células diferenciadas foram empregadas para quantificação dos mediadores inflamatórios (ELISA), acúmulo de triglicérides intracelulares (Oil red, microscopia de luz), produção de óxido nítrico (NO, reação de Greiss), expressão do receptor de aril hidrocarboneto (AhR, WB) e do proliferador de peroxissoma (PPAR-&#947;, WB). Os resultados obtidos mostraram que a exposição ao PCB126 (10, 30 ou 100&#181;M; 24, 48 ou 72 h) não alterou a viabilidade e proliferação celular; reduziu a porcentagem de células em apoptose (30, 100&#181;M; 24 ou 72 h); não alterou o ciclo celular (10, 30 ou 100&#181;M; 24 ou 72 h); induziu a fragmentação do DNA (10, 30 ou 100&#181;M; 24h); não induziu a geração de ROS (30, 100&#181;M; 24 ou 72 h); induziu a produção de NO (300&#181;M; 24 ou 72h); não alterou a secreção do fator quimiotáxico para monócito (MCP-1); aumentou a secreção do fator de necrose tumoral (TNF-&#945;; 100 ou 300&#181;M, 72 h) e da interleucina 12 (IL-12; 300&#181;M, 72 h); reduziu a secreção de interleucina 1&#946; (IL-1&#946;, 300 &#181;M, 72 h) e de interleucina 10 (IL-10; 300&#181;M; 24h, 100 ou 300&#181;M; 48 h; 100&#181;M, 72 h); aumentou a expressão de PPAR&#947; (100 ou 300&#181;M, 24h; 300&#181;M, 72h) e de AhR (300&#181;M, 72h); aumentou a concentração de triglicérides intracelulares (100 ou 300&#181;M; 24, 48 ou 72h). Em conjunto, os resultados obtidos mostram as ações diretas do PCB126 em células 3T3-L1 envolvidas na adipogênese, o que reforça, embora que em ensaios in vitro, o papel desta classe de poluentes na obesidade. / The polychlorinated biphenyl (PCB) 126 is a persistent organic pollutant and toxic to human being. The association between exposition to POPs and metabolic diseases has been described. Nevertheless this toxicity mechanism is not yet elucidated. This way this work aim to elucidate the exposure over pre adipocytes 3T3-L1 line to PCB 126, differentiated or not, focused on cellular death mechanisms, proliferation, differentiation and metabolism. The PCB126 was diluted in DMSO (0,13%). 3T3-L1 cells were maintained in Dulbecco´s modified Eagle´s medium (DMEM, 5% CO2 at 37º) and the differentiation process was performed by incubation with adpogenic cocktail solution by 10 days. The cells were incubated with different concentration of PCB126, DMSO (0,13%) or DMEM. Cells not differentiated were used on viability assays, death, proliferation, cell cycle and DNA fragmentation (flow cytometry) and reactive oxygen species production assay (ROS, fluorescence spectrophotometry). Differentiated cells were used to quantify inflammatory mediators (ELISA), Intracellular triglycerides accumulation (Oil red staining, light microscopy), nitric oxide production (NO, Greiss reaction), aril hydrocarbon receptor expression (AhR, Western Blot) and Peroxisome proliferator receptor gamma (PPAR-y, Western Blot). The obtained results showed that exposure to PCB126 (10, 30 or 100 &#181;M; 24, 48 or 72 hours) did not interfere on cellular viability and proliferation; reduced the cells percentage in apoptosis (30, 100 &#181;M; 24 or 72h); did not interfere on cellular cycle (10, 30 or 100 &#181;M; 24 or 72h); induced DNA fragmentation (10, 30 or 100 &#181;M; 24h); did not induced ROS generation (30, 100 &#181;M; 24 or 72h); induced the production of NO (300 &#181;M; 24 or 72h); did not alter the secretion of monocyte chemoattractant protein (MCP-1); enhanced the secretion of tumoral necrosis factor (TNF-&#945;; 100 or 300 &#181;M; 72h) and interleukin 12 (IL12; 300 &#181;M; 72h); reduced secretion of interleukin 1&#946; (IL1&#946; 300 &#181;M; 72h) and interleukin 10 (IL10; 300 &#181;M; 24h; 100 or 300 &#181;M; 48h; 100 &#181;M; 72h); increased PPAR-y expression (100 or 300 &#181;M; 24h; 300 &#181;M; 72h) and AhR (300 &#181;M, 24h); increased intracellular triglycerides concentration (100 or 300 &#181;M, 24, 48 or 72h). In summary the results show direct actions of PCB126 in 3T3-L1 cells evolved on adipogenesis, reinforcing, although in vitro, the role of this pollutant class on obesity.

Page generated in 0.086 seconds