• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 42
  • 11
  • 6
  • 2
  • Tagged with
  • 61
  • 23
  • 15
  • 15
  • 12
  • 9
  • 8
  • 8
  • 8
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Hand-Auge-Koordination bei videobasierten Augmented-reality-Systemen in der Schweiss- und Medizintechnik /

Park, Milda. January 2007 (has links)
Zugl.: Aachen, Techn. Hochsch., Diss., 2007.
52

Design of a Dual Band Local Positioning System

Joram, Niko 09 November 2015 (has links) (PDF)
This work presents a robust dual band local positioning system (LPS) working in the 2.4GHz and 5.8GHz industrial science medical (ISM) bands. Position measurement is based on the frequency-modulated continuous wave (FMCW) radar approach, which uses radio frequency (RF) chirp signals for propagation time and therefore distance measurements. Contrary to state of the art LPS, the presented system uses data from both bands to improve accuracy, precision and robustness. A complete system prototype is designed consisting of base stations and tags encapsulating most of the RF and analogue signal processing in custom integrated circuits. This design approach allows to reduce size and power consumption compared to a hybrid system using off-the-shelf components. Key components are implemented using concepts, which support operation in multiple frequency bands, namely, the receiver consisting of a low noise amplifier (LNA), mixer, frequency synthesizer with a wide band voltage-controlled oscillator (VCO) having broadband chirp generation capabilities and a dual band power amplifier. System imperfections occurring in FMCW radar systems are modelled. Effects neglected in literature such as compression, intermodulation, the influence of automatic gain control, blockers and spurious emissions are modeled. The results are used to derive a specification set for the circuit design. Position estimation from measured distances is done using an enhanced version of the grid search algorithm, which makes use of data from multiple frequency bands. The algorithm is designed to be easily and efficiently implemented in embedded systems. Measurements show a coverage range of the system of at least 245m. Ranging accuracy in an outdoor scenario can be as low as 8.2cm. Comparative dual band position measurements prove an effective outlier filtering in indoor and outdoor scenarios compared to single band results, yielding in a large gain of accuracy. Positioning accuracy in an indoor scenario with an area of 276m² can be improved from 1.27m at 2.4GHz and 1.86m at 5.8GHz to only 0.38m in the dual band case, corresponding to an improvement by at least a factor of 3.3. In a large outdoor scenario of 4.8 km², accuracy improves from 1.88m at 2.4GHz and 5.93m at 5.8GHz to 0.68m with dual band processing, which is a factor of at least 2.8. / Die vorliegende Arbeit befasst sich mit dem Entwurf eines robusten lokalen Positionierungssystems (LPS), welches in den lizenzfreien Frequenzbereichen für industrielle, wissenschaftliche und medizinische Zwecke (industrial, scientific, medical, ISM) bei 2,4GHz und 5,8GHz arbeitet. Die Positionsbestimmung beruht auf dem Prinzip des frequenzmodulierten Dauerstrichradars (frequency modulated continuous wave, FMCW-Radar), welches hochfrequente Rampensignale für Laufzeitmessungen und damit Abstandsmessungen benutzt. Im Gegensatz zu aktuellen Arbeiten auf diesem Gebiet benutzt das vorgestellte System Daten aus beiden Frequenzbändern zur Erhöhung der Genauigkeit und Präzision sowie Verbesserung der Robustheit. Ein Prototyp des kompletten Systems bestehend aus Basisstationen und mobilen Stationen wurde entworfen. Fast die gesamte analoge hochfrequente Signalverarbeitungskette wurde als anwendungsspezifische integrierte Schaltung realisiert. Verglichen mit Systemen aus Standardkomponenten erlaubt dieser Ansatz die Miniaturisierung der Systemkomponenten und die Einsparung von Leistung. Schlüsselkomponenten wurden mit Konzepten für mehrbandige oder breitbandige Schaltungen entworfen. Dabei wurden Sender und Empfänger bestehend aus rauscharmem Verstärker, Mischer und Frequenzsynthesizer mit breitbandiger Frequenzrampenfunktion implementiert. Außerdem wurde ein Leistungsverstärker für die gleichzeitige Nutzung der beiden definierten Frequenzbänder entworfen. Um Spezifikationen für den Schaltungsentwurf zu erhalten, wurden in der Fachliteratur vernachlässigte Nichtidealitäten von FMCW-Radarsystemen modelliert. Dazu gehören Signalverzerrungen durch Kompression oder Intermodulation, der Einfluss der automatischen Verstärkungseinstellung sowie schmalbandige Störer und Nebenschwingungen. Die Ergebnisse der Modellierung wurden benutzt, um eine Spezifikation für den Schaltungsentwurf zu erhalten. Die Schätzung der Position aus gemessenen Abständen wurde über eine erweiterte Version des Gittersuchalgorithmus erreicht. Dieser nutzt die Abstandsmessdaten aus beiden Frequenzbändern. Der Algorithmus ist so entworfen, dass er effizient in einem eingebetteten System implementiert werden kann. Messungen zeigen eine maximale Reichweite des Systems von mindestens 245m. Die Genauigkeit von Abstandsmessungen im Freiland beträgt 8,2cm. Positionsmessungen wurden unter Verwendung beider Einzelbänder durchgeführt und mit den Ergebnissen des Zweiband-Gittersuchalgorithmus verglichen. Damit konnte eine starke Verbesserung der Positionsgenauigkeit erreicht werden. Die Genauigkeit in einem Innenraum mit einer Grundfläche von 276m² kann verbessert werden von 1,27m bei 2,4GHz und 1,86m bei 5,8GHz zu nur 0,38m im Zweibandverfahren. Das entspricht einer Verbesserung um einen Faktor von mindestens 3,3. In einem größeren Außenszenario mit einer Fläche von 4,8 km² verbessert sich die Genauigkeit um einen Faktor von mindestens 2,8 von 1,88m bei 2,4GHz und 5,93m bei 5,8GHz auf 0,68m bei Nutzung von Daten aus beiden Frequenzbändern.
53

Absolute Positionierung unter Tage mittels transientelektromagnetischer Felder

Malecki, Stephan, Börner, Ralph-Uwe, Spitzer, Klaus January 2016 (has links)
Die dreidimensionale Positionsbestimmung unter Tage ist eine in der bergbautechnischen Praxis häufig gestellte Aufgabe. Die derzeit gebräuchlichen Verfahren basieren überwiegend auf zahlreichen relativen Messungen zwischen Festpunkten an der Erdoberfläche und dem zu bestimmenden Punkt unter Tage. Das hier vorgestellte Verfahren ist ein im geodätischen Sinn absolutes Verfahren. Die Punktbestimmung erfolgt direkt mit Hilfe der Festpunkte über Tage und dem unbekannten Punkt unter Tage. Relative Messungen zu benachbarten Punkten sind nicht notwendig. Die Grundlage des Verfahrens bildet die zeitliche Erfassung transienter elektromagnetischer Felder an einem zu bestimmenden Punkt unter Tage. Die Quellen dieser Felder sind gleichstromdurchflossene Drahtschleifen an der Erdoberfläche, die näherungsweise magnetische Dipole darstellen. Nach Abschalten des Stromes zerfällt das statische Magnetfeld und induziert elektrische Ströme in der leitfähigen Erde. Das transiente Magnetfeld wird unter Tage an einem Punkt für verschiedene Senderpositionen aufgezeichnet. Mit Hilfe eines Inversionsalgorithmus werden letztlich die dreidimensionalen Koordinaten des Messpunktes bestimmt. / Three-dimensional positioning in mines and caves is a common challenge. The methods currently used are based on numerous relative measurements. The method presented here is an absolute procedure in a geodesic sense. The coordinates of the unknown point are directly calculated using the surface points and the point underground. Relative measurements to neighboring points are not necessary. The localization procedure is based on recording transient electromagnetic fields under-ground. They are generated at the surface using direct-current carrying wire loops, which approximately represent magnetic dipoles. After shutoff the static magnetic field decays and induces electric currents in the conductive Earth. The transient electromagnetic field is recorded at an unknown point in the subsurface for different source positions. Finally, the three-dimensional coordinates of this point are reconstructed using an inversion algorithm.
54

Positioning of term infants during delivery room routine handling – analysis of videos

Konstantelos, Dimitrios, Gurth, Heidrun, Bergert, Renate, Ifflaender, Sascha, Rüdiger, Mario 07 July 2014 (has links) (PDF)
Background: Delivery room management (DR) of the newly born infant should be performed according to international guidelines, but no recommendations are available for an infant’s position immediately after birth. The present study was performed to answer the following questions: 1. How often is DR-management performed in term infants in side position? 2. Is routine DR-management possible in side position? 3. Is there any benefit of side position with respect to agitation or vital parameters? Methods: Cross-sectional study of video-recorded DR-management in term newborns delivered by C-section in 2012. Videos were analysed for infant’s position, administered interventions, vital parameters and agitation. Results: 187 videos were analysed. The Main Position (defined as position spent more than 70% of the time) was “supine” in 91, “side” in 63 and “not determinable” in 33 infants. “Supine” infants received significantly (p < 0.001) more often stimulation (12.5% of the total time) than “side” infants (3.9% of time). There were no differences between both groups with regard to suctioning; CPAP was exclusively (98%) administered in supine position. Newborns on side were less agitated than those on supine. There was a trend towards a better oxygenation in “side” positioned infants (p = 0.055) and significantly (p = 0.04) higher saturation values in “left-sided” infants than “right-sided” infants at 8th minute. “Side” positioned infants reached oxygen saturation values >90% earlier than “supine” positioned infants (p = 0.16). Conclusions: DR-management is feasible in the side position in term infants. Side position seems to be associated with reduced agitation and improved oxygenation. However, it remains unclear whether this represents a causal relationship or an association. The study supports the need for a randomized controlled trial.
55

Der Vorteil des ersten Zugriffs durch "Webpositioning" - das Internet als Schnittstelle von Markenrecht und Wettbewerbsrecht /

Rousseau, Marc-André. January 2007 (has links)
Thesis (doctoral)--Albert-Ludwigs-Universität Freiburg im Breisgau, 2007. / Includes bibliographical references (p. 271-284).
56

Positioning of term infants during delivery room routine handling – analysis of videos

Konstantelos, Dimitrios, Gurth, Heidrun, Bergert, Renate, Ifflaender, Sascha, Rüdiger, Mario 07 July 2014 (has links)
Background: Delivery room management (DR) of the newly born infant should be performed according to international guidelines, but no recommendations are available for an infant’s position immediately after birth. The present study was performed to answer the following questions: 1. How often is DR-management performed in term infants in side position? 2. Is routine DR-management possible in side position? 3. Is there any benefit of side position with respect to agitation or vital parameters? Methods: Cross-sectional study of video-recorded DR-management in term newborns delivered by C-section in 2012. Videos were analysed for infant’s position, administered interventions, vital parameters and agitation. Results: 187 videos were analysed. The Main Position (defined as position spent more than 70% of the time) was “supine” in 91, “side” in 63 and “not determinable” in 33 infants. “Supine” infants received significantly (p < 0.001) more often stimulation (12.5% of the total time) than “side” infants (3.9% of time). There were no differences between both groups with regard to suctioning; CPAP was exclusively (98%) administered in supine position. Newborns on side were less agitated than those on supine. There was a trend towards a better oxygenation in “side” positioned infants (p = 0.055) and significantly (p = 0.04) higher saturation values in “left-sided” infants than “right-sided” infants at 8th minute. “Side” positioned infants reached oxygen saturation values >90% earlier than “supine” positioned infants (p = 0.16). Conclusions: DR-management is feasible in the side position in term infants. Side position seems to be associated with reduced agitation and improved oxygenation. However, it remains unclear whether this represents a causal relationship or an association. The study supports the need for a randomized controlled trial.
57

Topography-controlled alignment of DNA origami nanotubes on nanopatterned surfaces

Teshome, Bezuayehu, Facsko, Stefan, Keller, Adrian 02 December 2019 (has links)
The controlled positioning of DNA nanostructures on technologically relevant surfaces represents a major goal along the route toward the full-scale integration of DNA-based materials into nanoelectronic and sensor devices. Previous attempts to arrange DNA nanostructures into defined arrays mostly relied on top-down lithographic patterning techniques combined with chemical surface functionalization. Here we combine two bottom-up techniques for nanostructure fabrication, i.e., self-organized nanopattern formation and DNA origami self-assembly, in order to demonstrate the electrostatic self-alignment of DNA nanotubes on topographically patterned silicon surfaces. Self-organized nanoscale ripple patterns with periodicities ranging from 20 nm to 50 nm are fabricated by low-energy ion irradiation and serve as substrates for DNA origami adsorption. Electrostatic interactions with the charged surface oxide during adsorption direct the DNA origami nanotubes to the ripple valleys and align them parallel to the ripples. By optimizing the pattern dimensions and the Debye length of the adsorption buffer, we obtain an alignment yield of ~70%. Since this novel and versatile approach does not rely on any chemical functionalization of the surface or the DNA nanotubes, it can be applied to virtually any substrate material and any top-down or bottom-up nanopatterning technique. This technique thus may enable the wafer-scale fabrication of ordered arrays of functional DNA-based nanowires.
58

Design of a Dual Band Local Positioning System

Joram, Niko 11 September 2015 (has links)
This work presents a robust dual band local positioning system (LPS) working in the 2.4GHz and 5.8GHz industrial science medical (ISM) bands. Position measurement is based on the frequency-modulated continuous wave (FMCW) radar approach, which uses radio frequency (RF) chirp signals for propagation time and therefore distance measurements. Contrary to state of the art LPS, the presented system uses data from both bands to improve accuracy, precision and robustness. A complete system prototype is designed consisting of base stations and tags encapsulating most of the RF and analogue signal processing in custom integrated circuits. This design approach allows to reduce size and power consumption compared to a hybrid system using off-the-shelf components. Key components are implemented using concepts, which support operation in multiple frequency bands, namely, the receiver consisting of a low noise amplifier (LNA), mixer, frequency synthesizer with a wide band voltage-controlled oscillator (VCO) having broadband chirp generation capabilities and a dual band power amplifier. System imperfections occurring in FMCW radar systems are modelled. Effects neglected in literature such as compression, intermodulation, the influence of automatic gain control, blockers and spurious emissions are modeled. The results are used to derive a specification set for the circuit design. Position estimation from measured distances is done using an enhanced version of the grid search algorithm, which makes use of data from multiple frequency bands. The algorithm is designed to be easily and efficiently implemented in embedded systems. Measurements show a coverage range of the system of at least 245m. Ranging accuracy in an outdoor scenario can be as low as 8.2cm. Comparative dual band position measurements prove an effective outlier filtering in indoor and outdoor scenarios compared to single band results, yielding in a large gain of accuracy. Positioning accuracy in an indoor scenario with an area of 276m² can be improved from 1.27m at 2.4GHz and 1.86m at 5.8GHz to only 0.38m in the dual band case, corresponding to an improvement by at least a factor of 3.3. In a large outdoor scenario of 4.8 km², accuracy improves from 1.88m at 2.4GHz and 5.93m at 5.8GHz to 0.68m with dual band processing, which is a factor of at least 2.8. / Die vorliegende Arbeit befasst sich mit dem Entwurf eines robusten lokalen Positionierungssystems (LPS), welches in den lizenzfreien Frequenzbereichen für industrielle, wissenschaftliche und medizinische Zwecke (industrial, scientific, medical, ISM) bei 2,4GHz und 5,8GHz arbeitet. Die Positionsbestimmung beruht auf dem Prinzip des frequenzmodulierten Dauerstrichradars (frequency modulated continuous wave, FMCW-Radar), welches hochfrequente Rampensignale für Laufzeitmessungen und damit Abstandsmessungen benutzt. Im Gegensatz zu aktuellen Arbeiten auf diesem Gebiet benutzt das vorgestellte System Daten aus beiden Frequenzbändern zur Erhöhung der Genauigkeit und Präzision sowie Verbesserung der Robustheit. Ein Prototyp des kompletten Systems bestehend aus Basisstationen und mobilen Stationen wurde entworfen. Fast die gesamte analoge hochfrequente Signalverarbeitungskette wurde als anwendungsspezifische integrierte Schaltung realisiert. Verglichen mit Systemen aus Standardkomponenten erlaubt dieser Ansatz die Miniaturisierung der Systemkomponenten und die Einsparung von Leistung. Schlüsselkomponenten wurden mit Konzepten für mehrbandige oder breitbandige Schaltungen entworfen. Dabei wurden Sender und Empfänger bestehend aus rauscharmem Verstärker, Mischer und Frequenzsynthesizer mit breitbandiger Frequenzrampenfunktion implementiert. Außerdem wurde ein Leistungsverstärker für die gleichzeitige Nutzung der beiden definierten Frequenzbänder entworfen. Um Spezifikationen für den Schaltungsentwurf zu erhalten, wurden in der Fachliteratur vernachlässigte Nichtidealitäten von FMCW-Radarsystemen modelliert. Dazu gehören Signalverzerrungen durch Kompression oder Intermodulation, der Einfluss der automatischen Verstärkungseinstellung sowie schmalbandige Störer und Nebenschwingungen. Die Ergebnisse der Modellierung wurden benutzt, um eine Spezifikation für den Schaltungsentwurf zu erhalten. Die Schätzung der Position aus gemessenen Abständen wurde über eine erweiterte Version des Gittersuchalgorithmus erreicht. Dieser nutzt die Abstandsmessdaten aus beiden Frequenzbändern. Der Algorithmus ist so entworfen, dass er effizient in einem eingebetteten System implementiert werden kann. Messungen zeigen eine maximale Reichweite des Systems von mindestens 245m. Die Genauigkeit von Abstandsmessungen im Freiland beträgt 8,2cm. Positionsmessungen wurden unter Verwendung beider Einzelbänder durchgeführt und mit den Ergebnissen des Zweiband-Gittersuchalgorithmus verglichen. Damit konnte eine starke Verbesserung der Positionsgenauigkeit erreicht werden. Die Genauigkeit in einem Innenraum mit einer Grundfläche von 276m² kann verbessert werden von 1,27m bei 2,4GHz und 1,86m bei 5,8GHz zu nur 0,38m im Zweibandverfahren. Das entspricht einer Verbesserung um einen Faktor von mindestens 3,3. In einem größeren Außenszenario mit einer Fläche von 4,8 km² verbessert sich die Genauigkeit um einen Faktor von mindestens 2,8 von 1,88m bei 2,4GHz und 5,93m bei 5,8GHz auf 0,68m bei Nutzung von Daten aus beiden Frequenzbändern.
59

Zielgruppensegmente und Positionierungsstrategien für das Marketing von Premium-Lebensmitteln / Target group segments and positioning strategies for the marketing of premium products

Lüth, Maren 19 May 2005 (has links)
No description available.
60

'The sight of sound': Gebärdensprachdolmetschen auf der lautsprachlichen Theaterbühne am Beispiel einer gedolmetschten Aufführung von 'My fair lady' am Hans Otto Theater Potsdam

Hildebrandt, Mandy 02 June 2016 (has links)
Während die Verdolmetschung lautsprachlicher Theateraufführungen in die Gebärdensprache in vielen Ländern selbstverständlich und regelmäßig angeboten wird, handelt es sich in Deutschland dabei noch um Einzelerscheinungen. Eine Ausnahme stellt das Hans Otto Theater Potsdam dar, das seit 1996 regelmäßig gedolmetschte Aufführungen anbietet und dabei die Methode des Shadow Interpreting nutzt. Am Beispiel einer gedolmetschten Aufführung von „My Fair Lady“ am Hans Otto Theater werden in dieser Arbeit folgende Aspekte der gebärdensprachlichen Verdolmetschung von Theateraufführungen untersucht: Stückauswahl, Dolmetscheranzahl und Rollenverteilung, Auswahl und Einführung von Namensgebärden der Figuren, Positionierung der Dolmetscher, Rollendarstellung und Rollenwechsel, Übertragung der akustischen Ebene des Aufführungstextes (linguistische und paralinguistische Informationen, Musik, Geräusche), äußere Erscheinung der Dolmetscher, Beleuchtung der Dolmetscher und die Inkorporation der Dolmetscher in die Aufgabe.

Page generated in 0.1412 seconds