• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 3
  • 1
  • Tagged with
  • 11
  • 11
  • 11
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Decision support for emergency handling in energy management systems

Hopley, Ingrid Elizabeth January 1993 (has links)
No description available.
2

Microprocessor control and instrumentation of electrical power systems

Singh, B. January 1987 (has links)
No description available.
3

Review of primary frequency control requirements on the GB power system against a background of increasing renewable generation

Pearmine, Ross Stuart January 2006 (has links)
The system frequency of a synchronous power system varies with the imbalance of energy supplied and the electrical energy consumed. When large generating blocks are lost, the system undergoes a frequency swing relative to the size of the loss. Limits imposed on the magnitude of frequency deviation† prevent system collapse. Operation of frequency responsive plant to control frequency, results in lower machine efficiencies. Changes to the generation mix on the British transmission system have occurred in the past ten years, when the response requirement was last reviewed. Future increased levels of wind turbines‡ will alter the operational characteristics of the system and warrant investigation. A process to optimise the response requirements while maintaining statutory limits on frequency deviation has been identified. The method requires suitable load and generator models to replicate transmission system performance. A value to substitute for current load sensitivity to frequency has been presented from empirical studies. Traditional coal fired generator models have been improved with additional functions to provide a comparable response with existing units. A novel combined cycle gas turbine model using fundamental equations and control blocks has also been developed. A doubly fed induction generator model, based on existing literature, has been introduced for representing wind turbine behaviour in system response studies. Validation of individual models and the complete system against historic loss events has established confidence in the method. A review of the current system with the dynamic model showed that current primary response requirements are inadequate. The secondary response requirements generally show a slight reduction in the holding levels. Simulations including extra wind generation have shown that there is potential to reduce the primary response requirement in the future. The secondary response requirements are maintained with added wind farms.
4

Real-time state estimation of a distributed electrical power system under conditions of deregulation

Kusekwa, Mashauri A. D. January 2010 (has links)
Thesis (DTech (Electrical Engineering))--Cape Peninsula University of Technology, 2010. / Static state estimation is a mathematical procedure in which physical measurements from sub-stations and physical model are combined in an optimal way. That is, the measurements obtained from the sub-stations are used with the physical model and the states of the power system are selected or calculated such that the states match the measurements in some best way. The states of a power system are the bus voltage magnitude and voltage angle of each bus of the system. Static state estimation is an increasingly common part of electrical power utility energy management systems (EMS). It plays a critical part in a day-to-day operation of a power system utility. The system measurements obtained from static estimation are used for realtime operations like optimal power flow calculations and contingency analysis. Proper system operations with regards to avoidance of insecure conditions includes situational awareness, therefore, the static estimator plays an important role in power system security. A further motivation: in increasingly electrical power deregulation, more economic operations mean savings for customers and electrical power provider alike. Economic benefit might be realized if system operators have a more accurate situational awareness of the system through improved power system state estimator. The objective of the study was to develop method, algorithm and MATLAB program for solution of power system state estimation using parallel processing techniques. In achieving the objective, the study has concentrated on development of an approximate Tanzanian power system network model comprising of 30 buses and used as a case study; decomposing the bus admittance matrix of the model into 3 interconnected sub-systems; development of mathematical model for real and reactive power injections, real and reactive power flows in the transmission lines and tie-lines connecting the sub-systems; development of measurement data model for voltage magnitude, real and reactive power injections, real and reactive power flows; formulating of a constrained weighted least absolute value state estimation problem; development of decomposition-coordination method and algorithm; and formulating algorithm and MATLAB program for solving the constrained state estimation problem using parallel processing technique.
5

Modeling and control coordination of power systems with FACTS devices in steady-state operating mode

Nguyen, Van Liem January 2008 (has links)
This thesis is devoted to the development of new models for a recently-implemented FACTS (flexible alternating current transmission system) device, the unified power flow controller (UPFC), and the control coordination of power systems with FACTS devices in steady-state operating mode. The key objectives of the research reported in the thesis are, through online control coordination based on the models of power systems having FACTS devices, those of maximising the network operational benefit and restoring system static security following a disturbance or contingency. Based on the novel concept of interpreting the updated voltage solutions at each iteration in the Newton-Raphson (NR) power-flow analysis as dynamic variables, the thesis first develops a procedure for representing the unified power flow controllers (UPFCs) in the steady-state evaluation. Both the shunt converter and series converter control systems of a UPFC are modeled in their dynamical form with the discrete time variable replaced by the NR iterative step in the power-flow analysis. The key advantage of the model developed is that of facilitating the process of UPFC constraint resolution during the NR solution sequence. Any relative priority in control functions pre-set in the UPFC controllers is automatically represented in the power-flow formulation. Although the developed UPFC model based on the dynamic simulation of series and shunt converter controllers is flexible and general, the number of NR iterations required for convergence can be large. Therefore, the model is suitable mainly for power system planning and design studies. For online control coordination, the thesis develops the second UPFC model based on nodal voltages. The model retains all of the flexibility and generality of the dynamic simulation-based approach while the number of iterations required for solution convergence is independent of the UPFC controller dynamic responses. Drawing on the constrained optimisation based on Newton’s method together with the new UPFC model expressed in terms of nodal voltages, a systematic and general method for determining optimal reference inputs to UPFCs in steady-state operation is developed. The method is directly applicable to UPFCs operation with a high-level line optimisation control (LOC) for maximising the network operational benefit. By using a new continuation technique with adaptive parameter, the algorithm for solving the constrained optimisation problem extends substantially the region of convergence achieved with the conventional Newton’s method. Having established the foundation provided by the comprehensive models developed for representing power systems with FACTS devices including the UPFC, the research, in the second part, focuses on real-time control coordination of power system controllers, with the main purpose of restoring power system static security following a disturbance or contingency. At present, as the cost of phasor measurement units (PMUs) and wide-area communication network is on the decrease, the research proposes and develops a new secondary voltage control where voltages at all of the load nodes are directly controlled, using measured voltages.
6

DESIGN OF SERVO CONTROL SYSTEM BY INTEGRAL VARIABLE STRUCTURE MODEL FOLLOWING CONTROL WITH APPLICATION TO ROLLER GEAR CAM AND POWER SYSTEM

Chang, Geeng-Kwei 01 January 2002 (has links)
A robust servo control system based on Integral Variable Structure Model Following Control (IVSMFC) is proposed. The IVSMFC approach comprises a reference model part for specifying the design requirements and an Integral Variable Structure Control (IVSC) part for minimizing the errors between the plant and the model. Sliding mode thus obtained features robustness against external disturbances and parameter variations. Design procedures in both continuous-time and discrete-time have been detailed. The IVSMFC-based servo control system has been successfully applied to a DSP-based brushless DC motor drive for globoidal cam indexing system and to power system. Simulation and experimental results demonstrate that the proposed scheme can achieve fast and robust responses.
7

Avaliação de métodos para projeto de controlador em dois níveis usando sinais de medição fasorial sincronizada / Methods assessment for controlling design on two levels using synchronized phasor measurement signals

Bento, Murilo Eduardo Casteroba 19 February 2016 (has links)
Esta proposta de pesquisa visa avaliar métodos de projeto de controladores em dois níveis, composto por controladores descentralizados e centralizado, utilizando sinais de medição fasorial sincronizada. Pesquisas iniciais foram realizadas utilizando a abordagem baseada na resolução da equação de Riccati num sistema multimáquinas, considerando aquisição de dados via medição fasorial sincronizada e atrasos de tempo nos canais de comunicação da entrada e da saída do controlador centralizado. Esta pesquisa propõe o projeto e avaliação de controladores centralizados através das abordagens baseadas na resolução da equação de Riccati, Desigualdades Matriciais Lineares e Algoritmos Genéticos. O projeto consiste em obter um controlador centralizado robusto a variações de carga e topologia do sistema, além de possíveis perdas de links de comunicação da entrada e da saída do controlador centralizado com o sistema elétrico. A fim de verificar a eficácia das abordagens de projeto foram utilizados o Sistema Equivalente Sul-Sudeste Brasileiro e o Sistema Simplificado Australiano. Além disso, simulações dinâmicas dos sistemas com aplicação de contingências foram realizadas com o propósito de se avaliar os controladores centralizados obtidos através de um modelo linear. Os resultados alcançados mostram semelhança e eficiência das abordagens quando se consideram múltiplos pontos de operação do sistema. A abordagem baseada em Algoritmos Genéticos se sobressai de acordo com os resultados obtidos para os sistemas-teste mencionados por propiciar um controlador centralizado robusto a múltiplos pontos de operação e possíveis perdas de links de comunicação. / This research proposal aims to compare control design methods on two levels, consisting of centralized and decentralized controllers, using signals synchronized phasor measurement. Initial researches have been conducted using the approach in solving the Riccati equation in a multi-machine system, considering data acquisition via synchronized phasor measurement and time delays in the communication channels of input and output of the centralized controller. This research proposes the design and comparison of centralized controllers through approaches based on resolution of the Riccati equation, Linear Matrix Inequalities and Genetic Algorithms. The project is to achieve a robust centralized controller to load variations and system topology changes and possible loss of communication of the input and output of the centralized controller with the electrical system. In order to verify the effectiveness of design approaches were used the Southern-Southeastern Brazil Equivalent Equivalent and Australian Simplified System. In addition, simulations of the dynamic systems with application of contingency were performed in order to evaluate the centralized controlling obtained by a linear model. The results show similarity and efficiency of the approaches when considering multiple system operating points. The Genetic Algorithms-based approach stands out according to the results obtained for the test systems mentioned, as demonstrated by the results, because it provides a robust centralized controller to multiple points of operation and possible loss of communication links.
8

Avaliação de métodos para projeto de controlador em dois níveis usando sinais de medição fasorial sincronizada / Methods assessment for controlling design on two levels using synchronized phasor measurement signals

Murilo Eduardo Casteroba Bento 19 February 2016 (has links)
Esta proposta de pesquisa visa avaliar métodos de projeto de controladores em dois níveis, composto por controladores descentralizados e centralizado, utilizando sinais de medição fasorial sincronizada. Pesquisas iniciais foram realizadas utilizando a abordagem baseada na resolução da equação de Riccati num sistema multimáquinas, considerando aquisição de dados via medição fasorial sincronizada e atrasos de tempo nos canais de comunicação da entrada e da saída do controlador centralizado. Esta pesquisa propõe o projeto e avaliação de controladores centralizados através das abordagens baseadas na resolução da equação de Riccati, Desigualdades Matriciais Lineares e Algoritmos Genéticos. O projeto consiste em obter um controlador centralizado robusto a variações de carga e topologia do sistema, além de possíveis perdas de links de comunicação da entrada e da saída do controlador centralizado com o sistema elétrico. A fim de verificar a eficácia das abordagens de projeto foram utilizados o Sistema Equivalente Sul-Sudeste Brasileiro e o Sistema Simplificado Australiano. Além disso, simulações dinâmicas dos sistemas com aplicação de contingências foram realizadas com o propósito de se avaliar os controladores centralizados obtidos através de um modelo linear. Os resultados alcançados mostram semelhança e eficiência das abordagens quando se consideram múltiplos pontos de operação do sistema. A abordagem baseada em Algoritmos Genéticos se sobressai de acordo com os resultados obtidos para os sistemas-teste mencionados por propiciar um controlador centralizado robusto a múltiplos pontos de operação e possíveis perdas de links de comunicação. / This research proposal aims to compare control design methods on two levels, consisting of centralized and decentralized controllers, using signals synchronized phasor measurement. Initial researches have been conducted using the approach in solving the Riccati equation in a multi-machine system, considering data acquisition via synchronized phasor measurement and time delays in the communication channels of input and output of the centralized controller. This research proposes the design and comparison of centralized controllers through approaches based on resolution of the Riccati equation, Linear Matrix Inequalities and Genetic Algorithms. The project is to achieve a robust centralized controller to load variations and system topology changes and possible loss of communication of the input and output of the centralized controller with the electrical system. In order to verify the effectiveness of design approaches were used the Southern-Southeastern Brazil Equivalent Equivalent and Australian Simplified System. In addition, simulations of the dynamic systems with application of contingency were performed in order to evaluate the centralized controlling obtained by a linear model. The results show similarity and efficiency of the approaches when considering multiple system operating points. The Genetic Algorithms-based approach stands out according to the results obtained for the test systems mentioned, as demonstrated by the results, because it provides a robust centralized controller to multiple points of operation and possible loss of communication links.
9

Projeto de controladores de sistemas de potência utilizando otimização bioinspirada / Power system controllers design using bio-inspired optimization

Peres, Wesley 28 March 2016 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-06-06T12:01:24Z No. of bitstreams: 1 wesleyperes.pdf: 8553175 bytes, checksum: 6f7d954432a35224645decbd6b1e94f7 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-07-02T13:24:49Z (GMT) No. of bitstreams: 1 wesleyperes.pdf: 8553175 bytes, checksum: 6f7d954432a35224645decbd6b1e94f7 (MD5) / Made available in DSpace on 2016-07-02T13:24:49Z (GMT). No. of bitstreams: 1 wesleyperes.pdf: 8553175 bytes, checksum: 6f7d954432a35224645decbd6b1e94f7 (MD5) Previous issue date: 2016-03-28 / Os Estabilizadores de Sistemas de Potência (ESP) têm sido usados por décadas para fornecer amortecimento às oscilações eletromecânicas através do controle de excitação dos geradores síncronos. No presente trabalho, são propostas metodologias para o projeto de estabilizadores por meio do ajuste de ganho e fase. O ajuste é realizado de forma simultânea (coordenada), considerando múltiplos pontos de operação com o objetivo de garantir a robustez dos controladores. Duas estruturas são consideradas: a descentralizada, que utiliza somente sinais locais, e a hierárquica, que utiliza sinais remotos. A dinâmica do sistema elétrico de potência é modelada em espaço de estados e o procedimento de ajuste é formulado como um problema de otimização para a maximização do coeficiente de amortecimento do autovalor dominante do sistema em malha fechada considerando todos os pontos de operação. As metodologias, aqui abordadas, são baseadas em métodos de otimização bioinspirados no comportamento de enxames: Enxame de Partículas e Eco-localização de Morcegos. São desenvolvidas metodologias híbridas baseadas no acoplamento dos métodos bioinspirados com o Método do Gradiente Descendente para o refinamento dos ganhos dos controladores de forma a melhorar a busca local do processo de otimização. Com o objetivo de manter a diversidade da população, estratégias baseadas em multipopulações também são propostas. As metodologias propostas foram validadas através da simulação de sistemas teste de pequeno e médio porte, que são normalmente utilizados na literatura especializada. Os resultados são considerados promissores e acredita-se que as metodologias propostas possam ser de grande valor nessa área de conhecimento. / Power system stabilizers have been used for decades in order to provide the necessary damping of power system oscillations through generators excitation control. In this thesis, methodologies for stabilizers design (gain and phase compensation tuning) are presented. All stabilizers are simultaneously designed (coordinated design) taking into account a set of pre-specified operating conditions in order to ensure robustness. Two control structures are considered: decentralized (based on the use of local signals) and hierarchical (that uses remote signals). The power system dynamic is modeled in state space and the tuning procedure is formulated as an optimization problem in order to maximize the damping coefficient associated to the dominant pole in closed-loop operation for all operating conditions. The proposed methodologies are based on optimization algorithms bio-inspired in swarm behavior: Particle Swarm Optimization and Bat Algorithm. Hybrid methodologies are developed through coupling bio-inspired methods to the Steepest Descent method in order to enhance the local search procedure during the optimization process (only the stabilizers gain are adjusted in the local search). Multipopulational approaches are also developed in order to prevent the population diversity lost. The proposed methodologies are validated by using small and medium-sized benchmark power systems. The results are considered to be promising and the proposed methodologies are found of a great value in this research field.
10

Sensory input encoding and readout methods for in vitro living neuronal networks

Ortman, Robert L. 06 July 2012 (has links)
Establishing and maintaining successful communication stands as a critical prerequisite for achieving the goals of inducing and studying advanced computation in small-scale living neuronal networks. The following work establishes a novel and effective method for communicating arbitrary "sensory" input information to cultures of living neurons, living neuronal networks (LNNs), consisting of approximately 20 000 rat cortical neurons plated on microelectrode arrays (MEAs) containing 60 electrodes. The sensory coding algorithm determines a set of effective codes (symbols), comprised of different spatio-temporal patterns of electrical stimulation, to which the LNN consistently produces unique responses to each individual symbol. The algorithm evaluates random sequences of candidate electrical stimulation patterns for evoked-response separability and reliability via a support vector machine (SVM)-based method, and employing the separability results as a fitness metric, a genetic algorithm subsequently constructs subsets of highly separable symbols (input patterns). Sustainable input/output (I/O) bit rates of 16-20 bits per second with a 10% symbol error rate resulted for time periods of approximately ten minutes to over ten hours. To further evaluate the resulting code sets' performance, I used the system to encode approximately ten hours of sinusoidal input into stimulation patterns that the algorithm selected and was able to recover the original signal with a normalized root-mean-square error of 20-30% using only the recorded LNN responses and trained SVM classifiers. Response variations over the course of several hours observed in the results of the sine wave I/O experiment suggest that the LNNs may retain some short-term memory of the previous input sample and undergo neuroplastic changes in the context of repeated stimulation with sensory coding patterns identified by the algorithm.

Page generated in 0.0758 seconds