• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • 2
  • 1
  • Tagged with
  • 8
  • 8
  • 6
  • 4
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Apport de l'électrophorèse capillaire pour l'étude des anomalies de glycosylation de protéines liées à des pathologies : vers l'identification de nouveaux biomarqueurs / Contribution of capillary electrophoresis for the study of disease-associated modifications in protein glycosylation : towards the identification of new biomarkers

Ruel, Coralie 13 December 2018 (has links)
La glycosylation est l’une des principales modifications post-traductionnelles des protéines. La glycosylation des protéines est fortement modifiée lors de diverses pathologies comme le cancer, la polyarthrite rhumatoïde ou les troubles congénitaux de la glycosylation («Congenital disorders of glycosylation», CDGs). Ainsi, la nature et les proportions relatives des oligosaccharides liés aux protéines peuvent être utilisées pour dépister, pronostiquer voire suivre l’évolution de pathologies. Les travaux de cette thèse se sont focalisés sur l’étude de la glycosylation pour permettre le dépistage de certaines pathologies : les CDGs, la maladie d’Alzheimer (MA) et la dégénérescence rétinienne. Plusieurs stratégies fondées sur l’électrophorèse capillaire (EC) ont été envisagées pour répondre à cet objectif. Tout d’abord, le développement d’une méthode par EC de zone (ECZ) l’apolipoprotéine C-III (ApoC-III) intacte, une O-glycoprotéine impliquée dans le dépistage des troubles de la O-glycosylation, a permis de séparer les différentes glycoformes selon leur degré de sialylation. L’analyse d’échantillons d’ApoC-III standard provenant de différents fournisseurs par spectrométrie de masse (MS) MALDI -TOF a mis en évidence une hétérogénéité liée à la présence (inattendue) de formes carbamylées. Un traitement du plasma basé sur une immunocapture de l’ApoC-III suivie d’une dérivation sur billes magnétiques de la protéine par un fluorophore a permis de séparer ses différentes glycoformes en ECZ. Ensuite, une analyse N-glycomique de fluides biologiques employant une nouvelle technique de préparation d’échantillon que nous avons adaptée au plasma et au liquide céphalorachidien, a été réalisée par EC en gel couplée à une détection par fluorescence induite par laser (ECG-LIF) sur des patients sains et atteints de la MA. Cette étude a permis de mettre en évidence quelques modifications des N-glycanes chez ces patients. Enfin la combinaison des deux stratégies d’analyse de la glycosylation (glycoprotéine intacte et glycanes libérés), a permis de détecter la transferrine intacte présente dans le liquide vitré à des concentrations faibles ainsi que ses N-glycanes libérés, dans le cadre du dépistage d’une maladie oculaire. L’EC-QTOF-MS a également été explorée pour l’analyse de N-glycanes dérivés avec un nouveau fluorophore permettant d’améliorer la sensibilité en MS. / Glycosylation is one of the most main types of post-translational modifications of proteins. Disease-associated modifications in protein glycosylation have been observed for various pathologies such as cancer, rheumatoid arthritis, or «Congenital disorders of glycosylation» (CDGs). They are often exploited for diagnosis, prognosis and monitoring of these diseases. This thesis work focused on the glycosylation study with the aim to allow the screening of different pathologies: CDGs, Alzheimer’s disease and retinal degeneration diseases. Different strategies based on capillary electrophoresis (CE) were considered to fulfil this goal. First, the developement of a CZE analysis of intact apolipoprotein C-III (ApoC-III), an O-glycoprotein implied in the screening of O-glycosylation disorders, allowed the separation of its glycoforms according to their sialylation degree. The MALDI-TOF mass spectrometry (MS) analysis of standard ApoC-III batches from different standard ApoC-III batches from different suppliers highlighted an additonnal heterogeneity due to (unexpected) carbamylated species. A plasma pretreatment based on an immunocapture of apoC-III followed by protein derivatization on magnetic beads using a fluorophore allowed to separate its glycoforms by CZE. Second, a glycomic analysis of biologicial fluids using a new sample treatment method that we adjusted to plasma and cerebrospinal fluid samples was performed by CGE-LIF on controls and Alzheimer’s patients. It allowed to highlight some modifications of N-glycans for this disease. Finally, the combination of both strategies of glycosylation analysis (intact glycoprotein and released N-glycans) allowed the detection of intact transferrin present in vitrous humor but also of its released N-glycans for the screening of retinal degeneration disease. CE-QTOF-MS was also investigated for the analysis of released N-glycans derivatized by a new fluorophore which increases MS sensitivity.
2

Méthodes physiques d’extraction de micro-organismes à partir d’échantillons sanguins à l'aide de microsystèmes / New methods for continuous microorganism separation from biological samples within a microsystem

Bisceglia, Émilie 07 November 2013 (has links)
Dans le domaine du diagnostic in vitro, l'étape d'extraction de micro-organismes à partir d'un échantillon complexe est une étape clé pour permettre l'identification du pathogène responsable d'une infection. Pour les septicémies, cette étape d'extraction est généralement précédée d'une étape de culture, ce qui conduit à une obtention des résultats au bout de plusieurs jours. Un résultat plus rapide (typiquement inférieur à 24h) permettrait d'augmenter le taux de survie des patients, et aurait ainsi une forte valeur ajoutée pour le corps médical. Le but de ces travaux est donc de développer une nouvelle méthode d'extraction et de concentration de pathogènes directement à partir d'un échantillon sanguin, sans étape de culture. Une stratégie en deux modules microfluidiques associés en série est proposée : elle repose sur la modification de la conductivité et de l'osmolarité de l'échantillon dans un premier module, puis sur la capture des micro-organismes par diélectrophorèse dans un second module. L'étude du premier module a permis de déterminer l'impact de la conductivité et de l'osmolarité du milieu sur les propriétés diélectriques des cellules. Deux voies ont ainsi été abordées, afin de diriger les cellules du sang et les micro-organismes vers un milieu de conductivité et d'osmolarité contrôlées : la dilution, et l'utilisation de forces acoustiques. L'étude du deuxième module a ensuite permis de démontrer la possibilité de capturer et concentrer des micro-organismes à partir d'un échantillon hypotonique et faiblement conducteur dans un écoulement microfluidique par diélectrophorèse. L'architecture d'un microsystème dédié a été définie grâce à un modèle numérique, puis validé expérimentalement avec des échantillons sanguins et différents micro-organismes (E. coli, S. epidermidis et C. albicans). La capture générique des micro-organismes est démontrée, et un taux de capture de 97% a été obtenu pour la séparation de \EC, avec une vitesse moyenne de l'échantillon dans le microsystème de 100 à 200 µm.s-1. Enfin, des perspectives d'amélioration sont présentées pour permettre d'effectuer cette étape de séparation sur un gros volume d'échantillon (1 à 10mL) en quelques heures, afin de répondre aux exigences imposées par l'urgence des tests de diagnostic des septicémies. / Extraction of pathogens from a biological sample is a key step for efficient diagnostic tests of infectious diseases. For bloodstream infections, current diagnostic methods are usually based on bacterial growth and take several days to provide valuable information. An accelerated result would have a high medical value to adjust therapeutic strategies. The aim of this study is to design a new approach for separation and concentration of microorganisms directly from a blood sample, to avoid time-consuming growth stages. We report a method based on two different microsystems connected in series: it combines modification of conductivity and osmolarity of the sample with generic capture of microorganisms by dielectrophoresis. First we explore the impact of conductivity and osmolarity on the dielectric properties of blood cells and microorganisms. Dilution and acoustic forces are both analyzed to transfer blood cells and microorganisms to the optimized buffer. Then we demonstrate the feasibility of achieving the dielectrophoretic separation of microorganisms from blood cells in a low conductivity and low osmolarity medium inside a fluidic device. The structure of the device is optimized with numerical simulations and experiments performed on blood samples and various microorganisms (E. coli, S. epidermidis and C. albicans).The generic capture of microorganisms is validated, and we achieved a separation of 97% efficiency with E. coli, with an optimal inlet velocity around 100-200 µm.s-1. Finally, we propose an improved microsystem to perform the sample preparation step on a larger volume (1-10mL) in a few hours, in order to fit the medical need.
3

Développement d'un dispositif microfluidique de Déplacement Latéral Déterministe (DLD) pour la préparation d'échantillons biologiques, en vue de l'extraction de vésicules extracellulaires / Development of a microfluidic device based on Deterministic Lateral Displacement (DLD) for biological sample preparation, towards the extraction of extracellular vesicles

Pariset, Eloïse 01 October 2018 (has links)
Les vésicules extracellulaires (EVs) apparaissent depuis une dizaine d'années comme de nouveaux biomarqueurs à fort potentiel pour des applications de biopsie liquide. En effet, les EVs portent la signature de leurs cellules émettrices, par le transport de matériel génétique et protéique cellulaire, qui peut être exploité comme outil de diagnostic précoce. L’une des principales limitations actuelles à l'utilisation clinique des EVs est la difficulté à extraire ces nano-objets à partir de biofluides complexes et à standardiser les protocoles de préparation d'échantillon. En effet, de nouvelles technologies sont requises pour effectuer un isolement efficace, bas coût et rapide de sous-populations d'EVs, sans altérer leur intégrité et à partir de faibles volumes d'échantillon. La technique microfluidique de Déplacement Latéral Déterministe (DLD) apparaît comme une des technologies prometteuses pour atteindre ces performances grâce à une purification passive et sans marquage. Les dispositifs de DLD mettent en oeuvre un réseau de piliers générant un tri en taille des particules, et dont les paramètres géométriques permettent de contrôler précisément le diamètre de séparation. Parmi les nombreuses applications de cette technologie dans le secteur biomédical, aucune ne permet pour le moment de réaliser l'extraction complète d'EVs directement à partir du biofluide d'intérêt, sans étapes de purification intermédiaires par centrifugation par exemple. Dans cette perspective, nos développements technologiques ont pour but d'améliorer la fiablilité, l'efficacité et l'intégration des dispositifs de DLD. A partir d'études numériques et expérimentales, nous proposons ici de nouveaux modèles pour anticiper au mieux le comportement des particules lors de la conception de réseaux de DLD. Par ailleurs, dans une approche orientée système, nous proposons également un packaging fluidique des dispositifs de DLD. Plusieurs étapes de tri étant généralement requises pour la purification d’échantillons biologiques, nos développements portent également sur la façon d’interconnecter ces modules au sein d'une configuration en série. Deux applications biologiques sont adressées et démontrent la versatilité de la technologie de DLD : l'isolement de bactéries E. coli à partir de prélèvements sanguins humains - en vue du diagnostic du sepsis - et l'extraction d'EVs dans des milieux de culture cellulaires - avec en perspective la détection d'EVs spécifiques par biopsie liquide. L'étape de préparation d'échantillon ne peut être dissociée de l'étape de caractérisation. C'est pourquoi, l'isolement des EVs devra dans un second temps être couplé à leur analyse au sein d'un dispositif intégré, portable et autonome, ce qui pourrait ouvrir de nouvelles perspectives vers l'application clinique des recherches actuelles sur les EVs. / Over the past decades, Extracellular Vesicles (EVs) have demonstrated strong potential as new biomarkers for liquid biopsy. Indeed, since EVs are fingerprints of parent cells, they can be exploited as early diagnostic tools. However, owing to their small size and high heterogeneity, EVs are challenging to extract from biofluids. In particular, reproducible and standardized protocols are required to perform fast, efficient, and cost-effective preparation of undamaged EV subpopulations from limited sample volumes. Deterministic Lateral Displacement (DLD) appears to be a promising microfluidic technology for this preparation by means of passive and label-free separation. DLD performs size-based separation of particles around a critical diameter that can be fine-tuned according to design parameters in an array of micropillars. Across the numerous biotechnological applications of DLD, none has yet successfully performed the complete extraction of EVs from unprocessed biofluids. This is the underlying motivation of this thesis, which outlines technological enhancements that make DLD separation more predictable, efficient, and easy-to-integrate. Based on both numerical and experimental developments, predictive models are proposed in order to anticipate particle behavior and to help in the design of efficient DLD devices. In addition to the optimization of single DLD devices, this thesis also addresses the issue of system integration. An innovative approach of serial connection between DLD modules is proposed to address the sequential sorting of particles from a complex biofluid and ensure that there is no loss of function of individual DLD devices when operated alone or in series. Two biological applications illustrate the potential of DLD-based sample preparation systems: the isolation of E. coli bacteria from human blood samples for sepsis diagnostics and the extraction of EVs from cell culture media with the perspective of liquid biopsy applications. And as sample preparation cannot be dissociated from detection or characterization, this thesis moreover highlights the potential integration of DLD in an all-in-one microfluidic device for both sample preparation and analysis of extracted EVs. Such a portable and autonomous device could overcome some of the current limitations with regard to the clinical use of EVs.
4

Analyse de défaillance de nouvelles technologies microélectroniques : nouvelles approches dans la méthodologie de préparation d’échantillon / Failure analysis of new microelectronic technologies : new approaches in the sample preparation flow

Aubert, Amandine 11 July 2012 (has links)
Dans le développement des technologies microélectroniques, l’analyse de défaillance permet par l’étude des mécanismes de défaillance potentiels de définir des solutions correctives. La mise en œuvre des techniques de localisation et d’observation des défauts requiert une méthodologie, dont l’étape clé est la préparation d’échantillons. Celle-ci doit continuellement évoluer pour s’adapter aux innovations technologiques qui introduisent de nouveaux matériaux, et augmentent la complexité des composants assemblés. Cette thèse s’est intéressée à la méthodologie de préparation d’échantillons pour l’analyse de défaillance de deux familles de produits : les produits discrets et IPAD, et les micro-batteries. Pour les produits discrets et IPAD, une optimisation de la méthodologie existante a été réalisée en intégrant de nouvelles approches, développées pour résoudre des cas jusqu’alors en échec. Pour les micro-batteries, les matériaux utilisés et leur architecture ont nécessité une remise en question complète de la méthodologie de préparation d’échantillon. / In the development of microelectronic technologies, the failure analysis makes it possible to define corrective actions thanks to the understanding of the failure mechanism. In order to define the most adequate localization and observation techniques to use, a failure analysis flow is required. The sample preparation is a key step of this flow. This flow must continuously evolve to take into account the technological innovations that introduce new materials, and increase the complexity of assembled components. This work concerned the sample preparation flow for the failure analysis of two product families : the discrete products and IPAD, and the micro-batteries. Concerning the discrete products and the IPAD, an optimization of the current flow was performed with the integration of new approaches developed to solve failed cases. For the micro-batteries, the used materials and their architecture required an entire reappraisal of the sample preparation flow.
5

Analyse de défaillance de nouvelles technologies microélectroniques : nouvelles approches dans la méthodologie de préparation d'échantillon

Aubert, A. 11 July 2012 (has links) (PDF)
Dans le développement des technologies microélectroniques, l'analyse de défaillance permet par l'étude des mécanismes de défaillance potentiels de définir des solutions correctives. La mise en œuvre des techniques de localisation et d'observation des défauts requiert une méthodologie, dont l'étape clé est la préparation d'échantillons. Celle-ci doit continuellement évoluer pour s'adapter aux innovations technologiques qui introduisent de nouveaux matériaux, et augmentent la complexité des composants assemblés. Cette thèse s'est intéressée à la méthodologie de préparation d'échantillons pour l'analyse de défaillance de deux familles de produits : les produits discrets et IPAD, et les micro-batteries. Pour les produits discrets et IPAD, une optimisation de la méthodologie existante a été réalisée en intégrant de nouvelles approches, développées pour résoudre des cas jusqu'alors en échec. Pour les micro-batteries, les matériaux utilisés et leur architecture ont nécessité une remise en question complète de la méthodologie de préparation d'échantillon.
6

Synthèse de sondes moléculaires pour l'imagerie multimodale et multi-échelle appliquée en science du vivant / Molecular probes synthesis for multimodal and multi-scale imaging in life science

Vorng, Jean-luc 16 December 2013 (has links)
Les travaux décrits dans ce mémoire ont pour objectif d'imager des cellules par des techniques d'imagerie complémentaires à la spectroscopie de fluorescence : la micro-spectroscopie Raman et l'imagerie NanoSIMS. Le présent manuscrit se divise en quatre chapitres et présente les différents aspects menant à la mise en place de ce projet. Le premier chapitre du manuscrit a pour but de positionner le projet d'un point de vue biologique. Ce chapitre présente l'organite que nous souhaitions marquer, le nucléole, et la façon dont nous avons procédé à sa localisation par l'intermédiaire de sondes moléculaires. Le marquage que nous avons choisi est un immuno-marquage indirect faisant intervenir deux anticorps : un anticorps primaire spécifique à la nucléophosmine, protéine majoritairement présente dans le nucléole et un anticorps secondaire, reconnaissant l'anticorps primaire, marqué par une sonde moléculaire d'intérêt. Ce chapitre a également permis de montrer par une analyse en immunofluorescence l'absence d'interférence des sondes moléculaires dans le cadre de ce marquage. Le second chapitre se focalise sur la synthèse des sondes moléculaires permettant le marquage des anticorps secondaires. Les sondes envisagées pour ce marquage possèdent un groupement ester de succinimide réactif capable de "s'accrocher" de manière covalente aux fonctions amines de l'anticorps secondaire et un ou plusieurs groupements fonctionnels visible par la technique d'imagerie voulue. Trois catégories de sondes ont été préparées et dépendent de la technique d'imagerie employée. Les sondes Raman comportant une triple liaison carbone-carbone visible par cette technique, les sondes NanoSIMS dont l'acquisition d'image sera possible par les halogènes présents dans la structure et les sondes bimodales comportant les deux éléments dans la même structure. Les sondes bimodales sont obtenues par le couplage pallado-catalysé de Sonogashira. Dans la dernière partie du chapitre, une nouvelle série de sonde a été envisagée dans le cadre d'une application future : le marquage de l'ATP-ϒ-SH grâce à une fonction mésylate. Les deux derniers chapitres ont pour but de mettre en application tout ce qui a été présenté dans les chapitres précédents. Les deux techniques employées permettent d'accéder à des types d'informations différentes : la spectroscopie Raman donne accès aux modes de vibrations d'une molécule tandis que l'imagerie NanoSIMS permet d'obtenir des informations élémentaires et isotopiques. Nous présenterons le cheminement suivi pour imager des cellules via leurs constituants par micro-spectroscopie Raman et imagerie NanoSIMS via les sondes moléculaires introduites. / Life sciences imaging are widely used for different applications, they are interested in medical diagnosis as well as basic research. In cells biology, fluorescence microscopy is mainly used for organelles observation at sub-cellular scale. However, techniques based on fluorescence phenomena are limited by some drawbacks like technical resolution, fluorescent dye degradation and the number of channels, which can be visualized. In this context, the exploration and the development of new way for image acquisition are considered as an experimental and technical scientific challenge. Furthermore, it can lead to complementary technique to fluorescence microscopy.This PhD thesis is a life science imaging project development and application allowing image acquisition base on molecular vibrations phenomena and elementary analysis in cells. Two techniques have been chosen in relation to both specificity: micro Raman spectroscopy and NanoSIMS imaging. Micro Raman spectroscopy allows the observation of molecular vibration mode at micron scale and NanoSIMS leads to elementary and isotopic sample information at sub-micronic scale. Combination of both techniques will lead to multi-scale and multi-modal imaging of biological samples. Molecular probes designing and synthesis for both techniques were used to visualize an organelle inside the nucleus: the nucleolus. Nucleolus has a key role in ribosomal RNA transcription and researchers shows some interest in the study of this organelle for his multifunctional role like ribosome biogenesis and nuclear organization. An immuno-labelling method combine with the introduction of molecular probes will allow nucleolus imaging by micro-Raman spectroscopy and NanoSIMS spectrometry. This immuno-labelling is specific to a phosphoprotein mainly localized inside the nucleolus: the nucleophosmin (NPM). In this project, the introduction of molecular probes in an immuno-labelling will act as a Raman Tag or a NanoSIMS tag for NPM's nucleolus observation and studies.This work at the interface between different fields: chemistry, biology and physics shows all the aspect of this project starting from molecular probes synthesis, immuno-labelling methods uses to direct application of both Raman and NanoSIMS techniques.
7

Nouvelles méthodes de préparation et d'analyse par combinaison de techniques synchrotron hyperspectrales pour l'étude de micro-fragments de peintures et d'autres matériaux du patrimoine culturel / New methods for the preparation and analyses of paint samples from Cultural Heritage artifacts with combined hyperspectral techniques.

Pouyet, Emeline 03 October 2014 (has links)
Le projet vise à développer une nouvelle approche méthodologique dans le but d'améliorer l'utilisation combinée de plusieurs techniques de microscopies infrarouge et X lors de l'analyse de fragments de peintures. Historiquement et ordinairement, les fragments de peintures sont préparés en coupes épaisses polies et les analyses sont réalisées à la surface de ces dernières. Bien que cette préparation d'échantillon facilite sa manipulation ainsi que son orientation lors des analyses, elle limite aussi l'efficacité et la faisabilité de certaines techniques de microscopie. Par conséquent, ce travail propose d'explorer une nouvelle stratégie analytique : la préparation et l'analyse de coupes fines. Ces deux étapes ont été optimisées et validées dans le cadre d'analyses par µFTIR, µXRD, µXRF et µXANES. En parallèle, de nouvelles possibilités analytiques ont été testées dans le cadre de l'analyse des peintures, basées sur la technique XANES plein champ. Les échantillons de peintures se sont révélés être d'excellents candidats pour évaluer les avantages et inconvénients de cette technique pour les matériaux du Patrimoine Culturel en général. / This project aims at developing a new methodological approach, providing a more efficient and synergetic use of FTIR and X-ray microscopies, for the analysis of painting fragments. Usually, painting fragments are prepared as polished sections and analyses are carried out on the cross-section surface. This sample preparation is easy to handle, however ends into critical constraints regarding feasibility and efficiency of micro-analyses. We propose to explore a different strategy: preparation and analysis of thin sections. These preparation procedures were first optimized and validated with µFTIR, µXRF, µXRD and µXANES. Besides, new methodological capabilities based on full-field/µXANES were assessed. Paintings were ideal candidates for estimating pros and cons of this new strategy for CH materials in general.
8

Méthodes physiques d'extraction de micro-organismes à partir d'échantillons sanguins à l'aide de microsystèmes

Bisceglia, Émilie 07 November 2013 (has links) (PDF)
Dans le domaine du diagnostic in vitro, l'étape d'extraction de micro-organismes à partir d'un échantillon complexe est une étape clé pour permettre l'identification du pathogène responsable d'une infection. Pour les septicémies, cette étape d'extraction est généralement précédée d'une étape de culture, ce qui conduit à une obtention des résultats au bout de plusieurs jours. Un résultat plus rapide (typiquement inférieur à 24h) permettrait d'augmenter le taux de survie des patients, et aurait ainsi une forte valeur ajoutée pour le corps médical. Le but de ces travaux est donc de développer une nouvelle méthode d'extraction et de concentration de pathogènes directement à partir d'un échantillon sanguin, sans étape de culture. Une stratégie en deux modules microfluidiques associés en série est proposée : elle repose sur la modification de la conductivité et de l'osmolarité de l'échantillon dans un premier module, puis sur la capture des micro-organismes par diélectrophorèse dans un second module. L'étude du premier module a permis de déterminer l'impact de la conductivité et de l'osmolarité du milieu sur les propriétés diélectriques des cellules. Deux voies ont ainsi été abordées, afin de diriger les cellules du sang et les micro-organismes vers un milieu de conductivité et d'osmolarité contrôlées : la dilution, et l'utilisation de forces acoustiques. L'étude du deuxième module a ensuite permis de démontrer la possibilité de capturer et concentrer des micro-organismes à partir d'un échantillon hypotonique et faiblement conducteur dans un écoulement microfluidique par diélectrophorèse. L'architecture d'un microsystème dédié a été définie grâce à un modèle numérique, puis validé expérimentalement avec des échantillons sanguins et différents micro-organismes (E. coli, S. epidermidis et C. albicans). La capture générique des micro-organismes est démontrée, et un taux de capture de 97% a été obtenu pour la séparation de \EC, avec une vitesse moyenne de l'échantillon dans le microsystème de 100 à 200 µm.s-1. Enfin, des perspectives d'amélioration sont présentées pour permettre d'effectuer cette étape de séparation sur un gros volume d'échantillon (1 à 10mL) en quelques heures, afin de répondre aux exigences imposées par l'urgence des tests de diagnostic des septicémies.

Page generated in 0.1539 seconds