• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 56
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 59
  • 59
  • 59
  • 23
  • 22
  • 20
  • 19
  • 18
  • 13
  • 13
  • 11
  • 9
  • 7
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Avaliação funcional de próteses totais e satisfação do paciente = correlação com performance mastigatória e limiar de deglutição / Functional assessment of dentures and patient satisfaction : correlation with masticatory performance and swallowing threshold

Lucena, Sílvia Carneiro de 16 August 2018 (has links)
Orientador: Altair Antoninha Del Bel Cury / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-16T11:46:32Z (GMT). No. of bitstreams: 1 Lucena_SilviaCarneirode_M.pdf: 2259749 bytes, checksum: 2b22cec4dff4521ca67b434ebf089b02 (MD5) Previous issue date: 2010 / Resumo: O sucesso da reabilitação com prótese total está condicionado ao atendimento de requisitos técnicos e da satisfação do paciente. Dentre os requisitos técnicos, usuários de prótese apontam a mastigação como mais importante, porém, estudos têm sugerido uma fraca associação entre a qualidade técnica da prótese e a satisfação dos pacientes. Desta forma, o objetivo deste estudo foi verificar a correlação entre a avaliação de próteses totais feita pelo paciente e pelo cirurgião-dentista, assim como investigar a correlação destas duas variáveis com medidas objetivas da função mastigatória. Foram selecionados 28 voluntários (cinco homens e 23 mulheres, idade média 71,1 anos), usuários de próteses totais há pelo menos seis meses, com boa saúde geral e sem sinais ou sintomas de disfunção temporomandibular. A avaliação da satisfação com as próteses pelo paciente foi realizada com auxílio da escala visual analógica (escores de 0-100) e a qualidade técnica das próteses foi avaliada por um cirurgião-dentista que atribuiu escore de 0 a 9 considerando aspectos funcionais. Os dentes posteriores das próteses foram avaliados quanto ao desgaste dental, considerando a presença ou ausência de anatomia oclusal. A função mastigatória foi avaliada pelo método de fracionamento de peneiras, no qual o voluntário mastigava porções de 17 cubos de Optocal. A performance mastigatória (PM) foi avaliada após 40 ciclos mastigatórios pelo tamanho mediano de partícula. O limiar de deglutição (LD) foi determinado pelo número de ciclos mastigatórios contados até o voluntário sentir vontade de deglutir e tamanho mediano da partícula obtida após esses ciclos. As correlações entre os resultados da avaliação da prótese pelo profissional com a satisfação do paciente e com a função mastigatória foram obtidas pelo coeficiente de Spearman. A correlação entre satisfação do paciente e função mastigatória foi determinada pelo coeficiente de Pearson. O Teste t foi aplicado para comparar os escores de satisfação entre as próteses superiores e inferiores e a função mastigatória entre indivíduos com e sem desgaste dental. O nível de confiança estabelecido foi de 95%. A satisfação geral dos pacientes com ambas as próteses obteve escore 49,1. A prótese superior obteve maiores escores de satisfação que a inferior para todos os fatores avaliados, mas apenas para estabilidade houve diferença estatisticamente significante (p=0,002). A avaliação da qualidade das próteses pelo profissional obteve escore mediano de 6 e não apresentou correlação com a satisfação do paciente. A análise da performance mastigatória e limiar de deglutição mostrou tamanho mediano de partícula de 5,5 (±1,0) mm e 4.9 (±1,2) mm, respectivamente. Os dados de ambos os testes mastigatórios não apresentaram correlação significativa com a satisfação do paciente (p>0,05). A correlação entre a função mastigatória e a qualidade da prótese não foi estatisticamente significante (PM: r=-0,103; LD: r=0,011) e não houve diferença do grau de trituração do alimento teste para as próteses com ou sem desgaste dental (PM: p=0,137; LD: p=0,589). Dentro das limitações do trabalho, pode-se concluir que não houve correlação entre a avaliação funcional das próteses totais e a satisfação do paciente e não foi observada correlação destas variáveis com a função mastigatória / Abstract: For a successful rehabilitation, it is important for complete dentures to accomplish adequate technical requirements and patients' satisfaction. Dentures wearers have pointed out an adequate mastication as the most important aspect of prosthetic rehabilitation, however, studies have suggested a poor association between patients' satisfaction and denture quality. Thus, the aim of this study was to evaluate the relation between patients' and dentists' assessment of dentures and the correlation of these variables with objective measures of masticatory function. Twenty eight volunteers (five men and 23 women, mean age 71.1 years), who wore both complete dentures for at least 6 months, with good general health and no signs or symptoms of temporomandibular joint disorders, were selected. Their level of satisfaction with dentures was assessed on a visual analogue scale (scores from 0 to 100) and the technical condition of dentures were evaluated by an experienced dentist that attributed scores from 0 to 9 considering functional aspects. Tooth wear was also assessed on posterior teeth of dentures considering the presence of occlusal anatomy. The evaluations of masticatory function were performed using a sieving method in which the volunteers were instructed to chew portions of 17 cubes of a standardized artificial test food, Optocal. The masticatory performance (MP) was assessed after 40 masticatory cycles by the median particle size. The swallowing threshold (ST) was determined by the number of cycles performed until the time the volunteers felt the urge to swallow and by the median particles size of comminuted food. The correlation of functional assessment of denture by dentist with volunteers' satisfaction and masticatory function were calculated by Spearman's correlation coefficients. The correlation between volunteers' satisfaction scores and masticatory function was performed by Pearson's correlation coefficient. Student t test was used to compare satisfaction scores between upper and lower dentures and also to compare masticatory function of subjects wearing dentures with and without excessive tooth wear. The significance level was fixed at 95%. The mean general satisfaction score of the volunteers with both dentures was 49.1. The means satisfaction scores for upper dentures were superior to the lower ones for all factors evaluated but significant differences were observed only for stability (p=0.002). Dentures assessment by dentist had a median score of 6 and had no correlation with patients' satisfaction. The median particle size anchieved by volunteers for masticatory performance and swallowing thresholds was of 5.5 (±1.0) mm and 4.9 (±1.2) mm, respectively. Data of both masticatory tests showed no significant correlation with patients satisfaction scores (p>0.05). No significant correlation was observed between masticatory function and dentist evaluation of dentures (MP: r=-0.103; SWT: r=0.011) and there was no different of food comminution between subjects with and without excessive tooth wear. (MP: p=0.137; SWT: p=0.589). Within the limitations of this study, it can be concluded that there was no correlation between functional assessment of dentures and patients' satisfaction and no correlation was observed between these variables and masticatory function / Mestrado / Protese Dental / Mestre em Clínica Odontológica
12

Influencia da forma do palato e da sorção de agua na adaptação de proteses totais

Arioli Filho, João Neudenir 25 February 1997 (has links)
Orientador: Saide Sarckis Domitti / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-22T09:35:23Z (GMT). No. of bitstreams: 1 ArioliFilho_JoaoNeudenir_M.pdf: 2981700 bytes, checksum: 24c8fa1c41812f1d51e9dbbe4a62b31e (MD5) Previous issue date: 1997 / Resumo: Neste trabalho foram analisadas as influências das fonnas geométricas dos palatos (triangular, oval e plano) e os tempos de armazenagem em água a 37:1:2 °c (24 horas, 15 e 30 dias) na adaptação das bases de próteses totais superiores confeccionadas com resina acrílica polimerizada termicamente. A metodologia consistiu na confecção de próteses totais superiores à partir de modelos mestres de gesso, devidamente duplicados em moldeiras individuais com silicona por adição e gesso pedra tipo IV. Após enceramento, inclusão, polimerização e demuflagem, as peças protéticas foram armazenadas em água nos períodos previamente determinados. Posterionnente, com auxílio de um aparelho específico adaptado à mna mesa de fixação, foi possível controlar o assentamento final das próteses sobre os respectivos modelos mestres e sua fixação com adesivo instantâneo. Orientados por guias existentes na própria mesa de fixação, foram realizados cortes padronizados com serra manual, correspondentes as regiões do selado periférico posterior ("post -dam"), fossas centrais dos primeiros molares e regiões distais dos caninos. Os desajustes entre as bases de resina acrílica e os modelos mestres foram mensurados com um microscópio comparador linear. Os resultados indicaram que existe uma significância estatística ao nível de 5 % nas fonnas geométricas do palato tendo o palato plano apresentado os menores desajustes. O palato triangular demonstrou os maiores valores de desajuste entre a base de resina acrílica e o modelo de gesso. As localizações dos cortes também apresentaram valores significantes estatisticamente, sendo que o corte mais posterior (corte I) revelou os maiores desajustes, seguido pelos cortes li e IIl, respectivamente. Os períodos de armazenagem em água destilada a 37:t2 DC não demonstraram qualquer significância estatística entre os dados. Desta maneira, os resultados indicaram que a região do "post-dam" foi a mais desfavorável à adaptação em prótese total, tendo a forma geométrica triangular do palato contribuído para o aumento dos desajustes que poderão interferir na retenção e estabilidade de próteses totais superiores / Abstract: The purpose of this study was to evaluate the influence of palate geometric shapes ( deep, intennediate and flat) and the period of storage in water at 3712 DC (24 hours, 15 and 30 days) related to the adaption of superior complete dentures bases of heat -cured acrylic resin. The superior complete dentures was confeccioned from master cast duplicated with individual trays using silicone and embebed with stone plaster. After waxed, cured and deflasked, the complete dentures were storaged in water in the previously determined periods. Afterly, with the aid of an especific instnnnent on fixation grip, it was possible to control the final adjustment of the dentures over the master cast and its fixation with instantanious adhesive. The cuts were made with manual saw in corresponding postpalatal region, central region of first molars and distal regions of canines. The disadjustment between acrylic resin base and cast stone was mesured with an linear microscope. The results showed an statistical significative difference when the most . posterior cut (cut l) was compared with the cuts H and lH. The greater disajustment was obtained in the cut l and the smallest one was observed in cut lH. The periods of storage in water at 37-:12 DC didn't show any statistic difference between the data. The results showed that the postpalatal region is the most adversely to the adaptation in total dentures, with the deep geometric shape increasing the disadjustments, being able to interfere in retention and stability of superior total dentures / Mestrado / Protese / Mestre em Clínica Odontológica
13

Programação de articuladores em protese total : comparação entre metodos

Cardoso, Luiz Antonio Morais, 1963- 08 January 1998 (has links)
Orientador: Jose Roberto Lovadino / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-23T03:09:08Z (GMT). No. of bitstreams: 1 Cardoso_LuizAntonioMorais_D.pdf: 1865461 bytes, checksum: eae73caa17a06a50397f7619a4458242 (MD5) Previous issue date: 1997 / Resumo: Neste estudo foram considerados dois valores de grande interesse protético: inclinação da trajetória condílica ântero-posterior (guia condilar) e ângulo de Bennett. Essas duas grandezas serviram para referência de comparação entre dois métodos de programação de articuladores empregados na confecção de próteses totais. O primeiro método foi o chamado desgaste de Paterson que utiliza arcos de orientação com mistura abrasiva, que atritados pelo próprio paciente, conforma individualmente cada conjunto, que por sua vez, serve para programar o articulador. O segundo método, chamado técnica de Nóbilo, emprega o registro intra oral modificado, permitindo que as posições de interesse para a programação do articulador sejam definidas e tranferidas com o auxílio de moldagens vestibulares das posturas. Os métodos foram aplicados em 27 pacientes desdentados totais. Para a inclinação da guia condilar, o método de Paterson obeve média de 26,10 graus e o de Nóbilo 30,87 graus. Para o ângulo de Bennnett, o método de Paterson conseguiu 13,14 graus e o de Nóbilo 16,34 graus. Para ambos os valores protéticos a análise de variância considerou haver diferença entre os resultados obtidos pelos métodos. No entanto, em relação ao lado das articulações, nenhum método detectou diferença / Abstract: In this study were considerate two values with big prosthetic interest: anterior-posterior trajectory inclination of condyle and Bennett angle. These two greatness were useful for reference to compare two methods of articulators programation employed in dentures construclion. The first method was called Paterson abrasion that wich utilize orientation arcs with abrasive misture, frictioned for the own patient conform individualy each conjunct; that which in this way serve to articulator shedule. The second method, called Nobilo's technique used the intra-oral register modifyed, allowing to be defined to the articulator sheduling to be able to be defined and transfered with the vestibular posture impression. The methods were apliyed in 27 patients. To the inclination of condylar guide, the Paterson method got 26.10 grades and Nobilo's one got 30.87 grades. To the Bennett angle, Paterson method got 13.14 grades and Nobilo's one got 16.34 grades. To both prosthetic values, the variance analysis considered to the difference between the results got for the two methods. Never the lless in articulations side relation, no one method detected differences / Doutorado / Protese / Doutor em Clínica Odontológica
14

Influencia das resinas acrilicas, tecnicas de polimerização e do periodo de armazenamento em agua na movimentação total superior

Arioli Filho, João Neudenir 10 March 1998 (has links)
Orientadores: Saide Sarkis Dominitti, Simonides Consani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-23T10:20:15Z (GMT). No. of bitstreams: 1 ArioliFilho_JoaoNeudenir_D.pdf: 3667904 bytes, checksum: af02ed1626db8a56027835c5e7ba4380 (MD5) Previous issue date: 1998 / Resumo: O objetivo deste estudo foi analisar a intluência do período de armazenagem e das técnicas de polimerização, em três marcas comerciais de resinas acrílicas, na movimentação dental de prótese total superior. As resinas acrílicas utilizadas foram LUCITONE 550 (polimerizada em banho de água a 740C por 9 horas e em microondas a 500 W por 3 minutos), QC20 (ciclo em água fervente por 20 minutos) e ACRON-MC (ciclo em microondas 500W por 3 minutos). As distâncias dentais foram mensuradas após o enceramento da prótese (To), inclusão (TI), polimerização e demutlagem (Tz) e nos períodos de 3 (T3), 7 (T4) e 30 dias (Ts) de armazenagem em água a 37°C. Os resultados obtidos foram submetidos ao teste de T~ey (p :::; 0,05) e permitindo concluir que: (1) A resina ACRONMC apresentou os maiores deslocamentos dentais~ (2) No período T3 (3 dias de armazenagem) ocorreram os maiores índices de deslocamentos dentais~ (3) Os períodos de armazenagem em água não compensaram totalmente as distorções~ e, (4) As distâncias entre pré-molares e molares mensuradas no plano horizontal nas direções látero-Iateral e ânteroposterior apresentaram contração e expansão respectivamente / Abstract: The objective of this study was to analyze the teeth movement during different cure techniques of three commercial acrylic resins and afier periods of water storage in upper complete dentures. The acrylic resins used and the cure techniques proposed were : LUCITONE 550 (cured in water 9 Hs at 74° C and energy microwave 550 W at 3 min.), QC-20 (cured in boiled water 20 min.) and ACRON-MC (cured in energy microwave 550 W at 3 min.). The teeth distances, measured in the frontal and sagital planes by linear microscopy, were taken afier denture wax (To), denture inc1usion(T 1), cureq and demuflask (T2) and in the periods of 3(T3), 7- (T4) and 30-day (Ts) water storage. The results were analysed for Tukey's test (p ~ 0,05) and permited to conc1ued that: (1) ACRON-M..Ç resin presented_the highes~h movement in all perioqs: (2) the 3-d.ro: water storage ITJJ showed--1he highest movement scores: (3) the water storage did not fully compensate the cur~ distortions in upper complete illnture anq (4) cont;rngion anq expansion occurreq among ~ ' measured frontal/sagital planes. respectively / Doutorado / Protese Dental / Doutor em Clínica Odontológica
15

Influencia do processamento, do polimento e da sorção de agua das resinas acrilicas, na desadaptação do bordo posterior de proteses totais superiores polimerizadas com energia de microondas

Rizzatti-Barbosa, Celia Marisa, 1957- 26 July 2018 (has links)
Tese (livre-docencia) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-26T12:43:08Z (GMT). No. of bitstreams: 1 Rizzatti-Barbosa_CeliaMarisa_LD.pdf: 2629405 bytes, checksum: 49683e3bcf132f8fb2bdd217e3bf70f2 (MD5) Previous issue date: 2000 / Resumo: O objetivo deste trabalho foi investigar o grau de alterações na adaptação ao modelo, da borda posterior de bases de prótese totais superiores polimerizadas por energia de microondas, em sete posições pré estabelecidas, em função de três tratamentos: o método de processamento (TO), o polimento (Tp) e a sorção de água (T30). Foram confeccionadas 24 réplicas de próteses totais superiores a partir de um padrão metálico fundido. Estas foram aleatoriamente divididas em dois grupos: o primeiro foi polimerizado com resina LUCITONE 550® em banho de água durante 9 horas a 73±2°C, e o segundo com resina Acron MC®, processada em forno de microondas durante 3 minutos a 500 W de potência. Após o processamento, as amostras foram polidas por método convencional em politriz de bancada, e armazenadas em água destilada durante 30 dias a 37±2°C. Em cada tratamento, o grau de desadaptação da região posterior foi avaliado em microscópio comparador linear, em sete pontos: a 1 mm do fundo de sulco vestibular esquerdo (PI), sobre a crista do rebordo esquerdo (P2), 10 mm à esquerda da linha mediana <P3), sobre a linha mediana (P4), 10 mm à direita da linlia mediana (P5), sobre a crista do rebordo direito (PÓ) e a 1 mm do fundo de sufco vestibular direito (P7). O maior grau de desadaptação observado foi em P4, após o processamento com energia de microondas (0,7141 mm) e o menor foi em PI, após a sorção de água das amostras processadas com energia de microondas (0,0983 mm). Os dados numéricos de desadaptação dos sete pontos para os três tratamentos foram submetidos à análise estatística pelo teste t e teste de Tukey (p<0,05), e os resultados permitiram concluir que: a) todas as amostras apresentaram desadaptação em todos os pontos, após terem sido processadas; b) em ambos os métodos de processamento, os locais que apresentaram maior desadaptação foram os pontos sobre os rebordos (P2 e P6) e na região central do palato (P4); c) as amostras polimerizadas através da energia de microondas apresentaram maior desadaptação que as polimerizadas por banho de água nos pontos sabre a região central do palato (P4), na região a 10 milímetros da linha mediana para o lado direito (P5) e na região sobre o rebordo direito (P6); d) após o polimento, as amostras polimerizadas por energia de microondas apresentaram maior desadaptação em relação às polimerizadas por banho de água nos pontos sobre os rebordos direito e esquerdo (P2 e P6), região central do palato (P4) e regiões a dez milímetros da linha mediana à direita e à esquerda (P3 e P5); e) após o período de armazenagem em água, todos os pontos de todas as amostras apresentaram menor desadaptação em relação aos valores apresentados após o processamento, g) após o período de armazenagem em água, as amostras polimerizadas com energia de microondas apresentaram maior desadaptação que as polimerizadas com banho de água, nas regiões central do palato (P4) e a 10 milímetros da linha mediana à direita (P5). Palavras-chave: prótese total, resina, energia de microondas, adaptação / Abstract: The aim of this research was to investigate the degree of adaptation at posterior border of denture bases cured by microwave energy, at seven pre-established reference positions, after each of three processing stages: the processing method (TO), the polishing (Tp) and the water sorption (T30). Twenty four maxillary dentures were constructed on an edentulous maxillary arch metal master die. They were divided in two groups: the first was cured with a LUCITONE 550 ® resin while immersed in a water bath for nine hours at 73°C, and the second was cured with Acron MC®, which was processed in a microwave oven (500W) for 3 minutes. After curing, the samples were polished by a conventional method, and then stored in distilled water for 30 days at 37°±2°C. The adaptation of the posterior border denture base to the master die was evaluated after each processing stage using a light microscope with a measuring graticule, at seven reference points: (PI). 1 mm medial of the point of maximal depth of the left buccal sulcus; (P2), on the left ridge crest; on the 10 mm to midline (P3); on the midline (P4); right 10 mm to midline (P5); on the right ridge crest (P6); and 1mm medial of the point of maximal depth of the right buccal sulcus (P7), The worst adaptation was observed at P4, after the microwave cure (0.7141 mm) and the closest adaptation was at PI after water adsorption with the microwave cured samples (0.0983 mm). The numerical data at the seven reference positions after the three processing stages was submitted to statistical analysis using a Y test and the Tukey test (p<0.05). The results were statistically significant and the following conclusions were obtained: a) after processing, all samples presented with decreased adaptability at all reference positions than before processing; b) with both curing methods, the reference positions that displayed the worst adaptability were the ridge crest positions (P2 and P6) and the midline position (P4); c) the samples cured by microwave energy displayed decreased adaptability when compared to the samples cured in the water bath at the midline position (P4), at the right 10 mm of midline (P5) and on the right ridge crest (P6); d) after polishing the samples cured by microwave energy had decreased adaptability compared to those cured in the water bath on both the right and left ndge crest (P2 and P6), the midline (p4) and left and 10 mm bilaterally of the midline (P3 ad P5); e) after storage in water, all samples displayed greater adaptability to the master die than that found immediately after processing, g) after storage in water, the microwave samples displayed decreased adaptability than the samples cured in the water bath at the midline (P4) and 10 mm to the right of the midline (P5>. Key-words - denture, resin, microwave energy, adaptation / Tese (livre-docencia) - Univer / Protese Dental e Periodontia / Livre-Docente em Clinica Odontologica
16

Efeito da ação de diferentes escovas, na manutenção das caracteristicas superficiais de reembasadores resilientes submetidos a escovação mecanica

Carmo Filho, Jose Lopes do 24 October 2000 (has links)
Orientador: Marcelo Ferraz Mesquita / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Campinas / Made available in DSpace on 2018-07-27T09:42:09Z (GMT). No. of bitstreams: 1 CarmoFilho_JoseLopesdo_M.pdf: 2851043 bytes, checksum: 65b6ca0779ecc240d74dba3e452b088c (MD5) Previous issue date: 2000 / Resumo: Este trabalho teve como objetivo avaliar "in vitro", o efeito da ação de diferentes escovas na manutenção das características superficiais de reembasadores resilientes. Foram confeccionadas 30 amostras, divididas em 6 grupos de variáveis, com 5 amostras para cada variável. Para a confecção das amostras, foram utilizadas matrizes acrílicas incluídas em muflas, obtendo um molde impresso no gesso e posteriormente preenchido com os materiais resilientes Dentuflex (ativado quimicamente) ou Eversoft (ativado termicamente). Os materiais foram manuseados seguindo as orientações dos fabricantes. As amostras foram submetidas à leitura de rugosidade superficial num rugosímetro Prazis modelo Rug-03 (AROTEC­Argentina). Em seguida, foram fixadas no recipiente metálico da máquina de escovação (Equilabor) e submetidas ao ensaio de escovação mecânica. Foram utilizadas as escovas: 1- Te_ de cerdas duras; 2- Johnson's 30, de cerdas extra macias; e 3- Phb, de cerdas ultra-suaves. As escovas foram presas a um dispositivo da máquina de escovação. No recipiente de escovação da máquina, foi colocada uma solução contendo 6g de dentifrício para 6ml de água. As amostras foram submetidas à movimentos lineares de escovação, totalizando 30.000 ciclos, sob carga estática de 200g. Após a escovação, foram realizadas novas leituras dos valores de rugosidade superficial, e os valores obtidos submetidos à análise de variância e ao teste de Tukey, com 5% de significância. O material Dentuflex apresentou valores de rugosidade superficial estatisticamente superiores aos apresentados pelo material Eversoft, antes da escovação. Após a escovação, o material Dentuflex apresentou valores estatisticamente semelhantes aos apresentados pelo Eversoft. Para o material Eversoft, a escova Tek provocou maior rugosidade superficial, seguida pela escova Johnson's, sendo que a escova Phb não alterou estatisticamente os valores de _rugosidade superficial. Para o material Dentuflex, as escovas Te_ Johnson's e Phb produziram valores estatisticamente semelhantes, entretanto a escova Phb parece ter provocado polimento na sua superficie, diminuindo seus valores de rugosidade superficial / Abstract: The aim ofthis study was to evaluate "in vitro" the effect ofbrushing on the surface features of resilient lining materiaIs. TIrirty samples were prepared and divided into 6 groups of variables with 5 test repetitions for each variable. The samples were made with acrylic matrixes placed in a flask to obtain a cast pressed molel, later filled with resilient lining materiaIs like Dentuflex ( chemically activated) or Eversoft ( thermally activated). The materiaIs were handled according to the manufacturer's directions. The samples were subjected to surface roughness readings in a roughness reOOing machine (prazis, model RUg-03, AROTEC- Argentine). They were fixed to the brushing machine (Equilabor) and submited to a mechanical brushing simulation. Three different brushes were used in the experiment: "l-Tek" with thick filaments, "2-Johnson's 30" with extra-soft filaments and "3-Phb " with ultra-soft filaments. The brushes were attached to a device in the brushing machine and a solution of 6g. of toothpaste/ 6 ml of water was placed in the brushing recipient of the machine. The samples were submited to linear brushing movements, totaling 30,000 cycles, under a 200g. static 1000 pressure. After the brushing, new readings of the surface roughness were made and the values obtained were subjected to variance analysis and the Tukey test, with 5% of significance. Before brushing, Dentuflex showed values of surface roughness statistically higher than the values obtained with Eversoft. After brushing, Dentuflex showed values statistically equivalent to the ones obtained with _Eversoft. The use ofEversoft with the three different brushes had the following results: the "PHb" brush did not statistically change the values of surface roughness. The use of "Tek" brush caused higher roughness, followed by the "Johnson's" brush, however, the Dentuflex with the "Tek", "Johnson's" and "PHb" brushes showed similar statistical values, however, the "Phb" brush seems to have polished the surface, thus decreasing the surface roughness values / Mestrado / Protese / Mestre em Clínica Odontológica
17

Influencia da pressão e temperatura no processo de sorção e perda de agua em resina acrilica polimerizada por energia de microondas

Carrilho, Eduardo 12 June 2000 (has links)
Orientador: Celia Marisa Rizzatti Barbosa / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-27T11:29:41Z (GMT). No. of bitstreams: 1 Carrilho_Eduardo_D.pdf: 7335257 bytes, checksum: 978543ef1a57f239aa1795cca8e71a0c (MD5) Previous issue date: 2000 / Resumo: O objetivo do presente trabalho foi verificar a influência da pressão e da temperatura sobre o índice de sorção e perda de água em amostras de resina termopolimerizável, processadas por energia de microondas à 500W durante três minutos, quando comparadas ao método de banho de água à 73 :t 1°C, por nove horas. Para tanto, foram confeccionadas 80 amostras, de acordo com a especificação n.o 12 da American Dental Association, reunidas em oito grupos (GI, GIl, GIII, GIV, GV, GVI, GVII e GVIII), com 10 repetições cada. Os grupos GI a GIV (grupo controle) continham as amostras processadas por banho de água, enquanto os grupos G V a G VIII continham as processadas por energia de microondas. A seguir, todos eles foram submetidos a dois tipos de tratamento de sorção de água: os GI, GIII, GV e GVII, ao de imersão em água destilada, pressão ambiente, temperatura de 37°C, por 30 dias; os GII, GIV, GVI e GVIII, ao de imersão em água destilada, pressão de 40 Lbs., temperatura de 90°C, por 60 minutos. Já no terceiro momento - teste de perda de água, os grupos foram assim divididos: os GI, GIl, GV e GVI foram submetidos à pressão ambiente, temperatura de 37°C e mantidos em estufa seca; os GIII, GIV, GVII e GVIII, à pressão ambiente, temperatura de 37°C e mantidos, dentro de um recipiente com água destilada, em estufa seca. Os resultados obtidos ao fim dos experimentos de (a) sorção de água e de (b) perda de água foram analisados estatisticamente pelo Teste t de Student e permitiram as respectivas seguintes constatações: a) da mesma forma que as do grupo controle, as amostras (GV, GVI, GVII e GVIII) polimerizadas por energia de microondas sorveram água. Deve-se ressaltar que, quando da análise e levando-se em conta o tipo de polimerização em relação ao tipo de sorção, não foi notada diferença significante; b) quando analisados os resultados do teste de perda de água, as amostras (GIII, GIV, GVII e GVIII) mantidas em estufa seca, porém dentro de um recipiente com água destilada, continuaram ganhando peso. Tais constatações ensejam concluir que as amostras polimerizadas por energia de microondas terão uma sorção total e organizada quando submetidas a uma pressão de 40 Lbs. (teste de sorção) e mantidas em água destilada à 3 7°C (teste de perda de água) / Abstract: The aim of the present work was verify the influence of the pressure and temperature on the index of the sorption and desorption of acrylic resin cured by energy of microwaves at 500W for 3 minutes and compared to the method of water bathing for 73 ±J: l°e for 9 hours. Eighty samples were made in agreement with the specification n.o 12 of Dental American Association. The samples were joined in 8 groups (GI, GIl, GlIl, GIV, GV, GVI, GVIl and GVIII) with 10 repetitions each one. The groups I to IV was cured by water bathing and the groups V to VIII were cured by microwaves energy, they were still divided with the following treatments of water sorption: (GI, GIII, GV and GVII) immersion in water, pressure sets, temperature of 37°e for 30 days; (GII, GIV, GVI and GVIII) immersion in water, pressure of 40 Lbs., temperature of 90oe for 60 minutes. After this period the groups were submitted to the sorption test described by the specification n.o 12 of A. D. A.. For the desorption test the groups were divided in: (GI, GII, GV and GVI) pressure sets, temperature of 37°e and inside dry heater; (GIII, GIV, GVII and GVIII) pressure sets, temperature of 37°e and inside the water in dry heater. The results were statistically analized by "t" test and when analized they allowed to conclude that the resins that were submitted to the sorption test gained water and consequently weight increasing, and the samples that were submitted to the pressure increase, temperature, whose desorption occurred inside the water, had their weight stabilized with no alterations. Keywords: acrylic resin, microwaves, water sorption, water desorption / Doutorado / Protese Dental / Doutor em Clinica Dental
18

Efeito da termociclagem na deformação permanente e na resistencia a tração da união entre materiais reembasadores resilientes e resinas acrilicas

Pinto, Jose Renato Ribeiro 27 July 2018 (has links)
Orientador : Marcelo Ferraz Mesquita / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-27T15:44:52Z (GMT). No. of bitstreams: 1 Pinto_JoseRenatoRibeiro_M.pdf: 2240755 bytes, checksum: bba30074db6c533e3f9e02730326069b (MD5) Previous issue date: 2001 / Mestrado
19

Efeito do tempo pos-prensagem sobre a rugosidade, dureza e porosidade superficial da resina acrilica QC 20, em diferentes ciclos de polimerização

Borges, Luiz Henrique 15 February 2001 (has links)
Orientadores : Saide Sarckis Domitti, Simonides Consani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-27T17:36:03Z (GMT). No. of bitstreams: 1 Borges_LuizHenrique_D.pdf: 3778776 bytes, checksum: e1a8e978c93c200285af8af68e063845 (MD5) Previous issue date: 2001 / Resumo: Este trabalho teve o objetivo de avaliar o efeito do tempo pós-prensagem sobre a rugosidade, dureza superficial e porosidade da resina acrilica QC-20, em diferentes ciclos de polimerização. Para a confecção dos 81 corpos-de-prova foram utilizadas matrizes circulares de silicona de condensação medindo 30 mm de diâmetro e 5 mm de espessura, obtidas através de um molde padrão. As matrizes foram incluídas em muflas metálicas emuflas com reforço de fibra de vidro. A proporção pó/líquido, e a prensagem da resina acrílica foram feitas de acordo com as instruções do fabricante. As muflas foram deixadas em descanso por 30 minutos, 12 e 24 horas antes da polimerização que foi realizada nos ciclos de água aquecida a 74°C por 9 horas, 20 minutos em água em ebulição, e energia de microondas por 3 minutos a 500 W. Após o resfriamento em temperatura ambiente, os corpos-de-prova foram submetidos aos processos de acabamento e polimento em politriz, e submetidos aos testes de rugosidade superficial média, através do rugosímetro Surfcorder SE 1700, dureza superfical em um microdurômetro Shimadzu, e porosidade superficial, através da imersão dos corpos-de-prova em tinta nankin por 8 horas, contados em área determinada. Os resultados obtidos foram submetidos à análise de variânci_ e ao teste de Tukey ao nível de significância de 5%. Concluiu-se que não houve diferenças significativas entre as médias obtidas pelos métodos para as variáveis rugosidade e porosidade. Para a variável dureza superficial, houve diferenças significativas entre o método convencional e os outros dois métodos, mostrando que o método convencional apresentou menor dureza em relação aos demais / Abstract: The purpuse of this study was to investigate the effect of post-pressing step time on the roughness, surface hardness Knoop and porosity of a QC-20 acrylic resin in different polymerization cycles. Specimens were manufactured using 30 mm high and 5 mm thick round condensation silicone matrices, obtained through a standard method. The matrices were placed in metallic and in fiberglass-reinforced mufles. Powderlliquid ratio and acrylic resin pressing were carried as recommended by the manufacturer. Mufles were allowed to rest in the 0011 press for 30 minutes, 12 and 24 hours before being polymerized in heated water, boiling water and microwave energy cycles at 74°C for 9 hours. Afier cooling in room temperature, specimens were fmished and polished with politriz. Afterwords, specimens were submitted to superficial roughness test, using roughness tester Surfcorder SE 1700; to a superficial hardness test in a microdurometer Shimadzu 2000, and apparent porosity in which specimens were immersed in Nankin ink for 8 hours, being sectioned in a determined area later. The results were submitted to variance analysis and Tukey's test 5% significance leveI. 1t was concluded that there were no significant differences between the averages obtained by the methods used for roughness and porosity. For superficial hardness, there were significant differences between the conventional method and the other two used, showing that the conventional method demonstrated less hardness when compared to the others / Doutorado / Protese / Doutor em Clínica Odontológica
20

Efeito do tempo pos-prensagem na adaptação das bases de proteses totais confeccionadas com resina acrilica QC-20 em diferentes ciclos de polimerização

Padovan, Silvia Helena Marques 20 February 2001 (has links)
Orientadores : Saide Sarckis Domitti, Simonides Consani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-27T21:17:11Z (GMT). No. of bitstreams: 1 Padovan_SilviaHelenaMarques_D.pdf: 15209835 bytes, checksum: 2dde449f58929c4e56d3f8ca768ea66f (MD5) Previous issue date: 2001 / Resumo: Este trabalho verificou a influência do tempo de pósprensagem (imediato, 12 horas e 24 horas) em diferentes ciclos de polimerização, na adaptação de bases de prótese total confeccionadas com resina acrílica de rápida polimerização QC-20. Foram confeccionados 45 modelos em gesso pedra a partir da moldagem de um modelo mestre metálico. Sobre estes modelos foram confeccionadas bases de prótese com espessura uniforme de 1,5 mm, divididas aleatoriamente em 9 grupos de 5 amostras e incluídas em muflas específicas. Os grupos foram constituídos de acordo com o tipo de tratamento que as amostras foram submetidas: Grupo 1- pósprensagem imediato e polimerização convencional; Grupo 2- pós-prensagem imediato e polimerização por ciclo rápido; Grupo 3- pós-prensagem imediato e polimerização por energia de microondas; Grupo 4- pós-prensagem 12horas e polimerização convencional; 5- pós-prensagem 12horas e polimerização por ciclo rápido; Grupo 6- pós-prensagem 12 horas e polimerização por energia de microondas; , Grupo 7- pós-prensagem 24 horas e polimerização convencional; 8- pós-prensagem 24 horas e polimerização por ciclo rápido; Grupo 9- pós-prensagem 24 horas e polimerização por energia de microondas; Após o resfriamento das muflas em temperatura ambiente, as bases de prótese foram removidas, limpas, acabadas e fixadas em seus respectivos modelos com adesivo instantâneo Super Bonder (Loctite). O conjunto, base de prótese modelo foi seccionado em três secções látero-Iaterais (anterior, médio e posterio) e as superfícies seccionadas lixadas numa politriz. Em cada secção foram marcados 7 pontos referenciais para a leitura da desadaptação, verificada num microscópio para mensuração linear e os resultados obtidos foram submetidos à análise de variância e ao teste de Tukey em nível de significância de 5%. De acordo com os resultados obtidos pudemos concluir que não houve interfêrencia dos tempos de pós-prensagem nos níveis de desajuste das bases de prótese total. O maior desajuste foi obtido no corte C (posterior) independente dos fatores tempo de espera e ciclos de polimerização / Abstract: This study evaluated the influence of the post-compressing rest time (immediate, 12 h and 24 h) and the cycles of polymerization (conventional, fast cycle, and by microwave energy) on the adaptation of complete denture bases made with the fast polymerization acrylic resin QC-20. Forty-five plaster rock models were made from a metallic master model of an edentulous maxilla. Using these models, denture bases with a uniform thickness of 1.5 mm were obtained. These bases were then randomly divided into 9 groups of 5 samples each: Group 1- post-compressing rest immediate time and conventional polymerization; Group 2- post-compressing rest immediate time and fast cycle polymerization; Group 3- post-compressing rest immediate time and polymerization by microwave energy; Group 4- post-compressing rest time 12 h and conventionalpolymerization;Group 5- post-compress ingrest time 12 h and fast cycle polymerization; Group 6- post-compressing rest time 12 h and polymerization by microwave energy; Group 7- post-compressing rest time 24 hours and conventional polymerization; Group 8- postcompressing rest time 24 hours and fast cycle polymerization; and Group 9- post-compressing rest time 24 hours and polymerization by microwave energy. After cooling the flasks at room temperature, the denture bases were removed, trimmed, finished and fixed in their respective plaster models with adhesive Super Bonder (Loctite). The denture base-modeI set was sectioned in three frontal sections, and the surfaces were polished with sandpaper in an electric polishing machine. In each section, seven reference points were marked for the recording of the gap between base and model using an optical microscope. Data were analyzed at the 5 % leveI of significance. The results suggest that the post-compressing rest time did not influence the adaptation of denture bases. The widest gap occurred in section C (posterior) independent1y of the post-compressing rest time and cyc1e of polymerization / Doutorado / Protese Dental / Doutor em Clínica Médica

Page generated in 0.0993 seconds