• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 56
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 59
  • 59
  • 59
  • 23
  • 22
  • 20
  • 19
  • 18
  • 13
  • 13
  • 11
  • 9
  • 7
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Avaliação da precisão de metodos utilizados na determinação do desajuste das bases de protese total

Hayacibara, Roberto Masayuki 19 April 2001 (has links)
Orientadores : Saide Sarckis Domitti, Simonides Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T03:49:16Z (GMT). No. of bitstreams: 1 Hayacibara_RobertoMasayuki_M.pdf: 2978473 bytes, checksum: deedb6107fb0c5076942b5ad9d4ad29b (MD5) Previous issue date: 2001 / Resumo: O objetivo deste trabalho foi avaliar a precisão de dois métodos utilizados na determinação do desajuste das bases de prótese total, confeccionadas com resina acrílica ativada termicamente. Foram obtidos 10 modelos em gesso pedra a partir de um molde de silicone representando uma arcada superior desdentada normal. Sobre os modelos foram confeccionadas as bases de pro:va, incluídas em mufla pela técnica de rotina com polimerização da resina acrílica em banho de água aquecida a 74 :f:2°C por 9 horas. Após esfriamento das muflas em temperatura ambiente, as bases de prótese foram removidas, limpas e acabadas. Em cada conjunto modelo-base de prótese foram demarcadas três linhas transversais (anterior, médio e posterior) e em cada linha foram marcados 5 pontos (fundo de sulco vestibular esquerdo e direito, crista do rebordo esquerdo e direito e linha mediana) onde foram feitas as mensurações. Os métodos estudados na verificação da desadaptação foram: A- interposição de silicona por condensação entre a base e o modelo e a aferição com paquímetro digital modificado; B- após fixação da base no modelo com adesivo, três cortes transversais foram efetuados e as mensurações feitas com microscópio comparador linear. Os dados foram submetidos a Análise de Variância e ao teste de Tukey (5% de significância) que mostraram que o método da medição linear com microscópio comparador foi mais preciso que o método da interposição de silicona, revelando desadaptação com valores estatisticamente menor e significantes, quando foram considerados os fatores método, região e pontos estudados / Abstract: The aim of this study was to evaluate the accuracy of two measurement methods used for the detennination of the adaptation and stability of denture bases made of thermopolymerizing acrilic resin. One rubber mold was used to produce ten identical maxillary edentulous casts in dental stone. Ten denture bases were included into flasks and processed by the conventional method of polymerization (thennostatically controlled water bath for 9 hours at 74 :t2°C) above the dental casts. After cooling at room temperature, the denture bases were removed ITom the flasks, cleaned and trimmed. In each cast with the denture in place, three transversallines settled in the anterior, medial and posterior regions were demarcated, and in each line the space between the base and the cast was measured at 5 reference points (left and right sulcus depth, left and right ridge crest and midpalatal points). Two methods were used: A- interposition of an impression material (silicone rubber) and measurement of its thickness using a modified caliper; B- after fixation of the bases into the casts with adhesive, they were transversely seccioned at the reference lines and read in a linear comparator microscope. AlI data were analysed by ANOV A and Tukey test (5%), and it was concluded that the analyses done by using microscope were more accurate than the interposition of the impression material, revealing for the former method, statistically significant low values, considering methods, regions and points studied. / Mestrado / Protese Dental / Mestre em Clínica Odontológica
22

Efeito do numero de ciclos termicos sobre a deformação permanente de materiais reembasadores resilientes e sua resistencia a tração da união com a resina acrilica

Pinto, Jose Renato Ribeiro 11 July 2002 (has links)
Orientador: Marcelo Ferraz Mesquita / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-02T19:45:26Z (GMT). No. of bitstreams: 1 Pinto_JoseRenatoRibeiro_D.pdf: 3564212 bytes, checksum: a1dc81c846bf56c322b5ab2a519b1da2 (MD5) Previous issue date: 2002 / Resumo: O objetivo deste estudo foi avaliar o efeito do número de ciclos térmicos sobre a deformação permanente e resistência à tração da união com resina acrílica, de reembasadores resilientes definitivos usados como forradores de bases de próteses: um à base de silicone (Softliner), e outro à base de resina acrílica (Eversoft). Para o ensaio de resistência à tração da união, estes materiais foram unidos a uma resina acrílica (QC-20), e para o de deformação, não. Para a confecção das amostras foram utilizadas matrizes metálicas (40 x 10 x 10 e 13 x 19 mm) incluídas em mufla, cujo molde impresso na silicone por condensação e no gesso foi preenchido com resina acrílica e/ou material resiliente. Foram confeccionadas 400 amostras, metade para o ensaio de resistência à tração da união e metade para o de deformação permanente, divididas em 10 grupos, com 10 amostras por material para o ensaio de tração, e 10 para o de deformação permanente: grupo I - não submetido à termociclagem (grupo controle); grupo II -200 ciclos; grupo III - 500 ciclos; grupo IV - 1000 ciclos; grupo V - 1500 ciclos; grupo VI - 2000 ciclos; grupo VII ¿2500 ciclos; grupo VIII - 3000 ciclos; grupo IX -3500 ciclos e grupo X - 4000 ciclos. O tratamento térmico foi realizado no aparelho termociclador MSCT-3 plus com ciclos de imersão de 1 minuto em água a 5°C (± l°C) e 1 minuto em água a 55°C (±1°C). Para o ensaio de resistência à tração da união, as amostras foram adaptadas às garras autotravantes de uma máquina de ensaios universal EMIC DL-500 MF, com velocidade de 5 mm/minuto. Para o ensaio de deformação permanente, foi utilizado um dispositivo mecânico descrito na especificação nº 18 da A.D.A. Os dados obtidos foram submetidos à análise de variância (ANOVA) e as médias comparadas pelo Teste de Tukey, em nível de 5% de probabilidade, e as amostras do ensaio de resistência à tração da união, observadas quanto ao tipo de falha ocorrida (adesiva, coesiva ou mista). O material Softliner submetido aos diferentes números de ciclos térmicos não apresentou diferença estatística nos valores de resistência à tração da união, entretanto, o material Eversoft, quando se comparou o grupo controle (0,47 MPa) e o de 500 ciclos (0,46 MPa) com o de 4000 ciclos térmicos (0,70 MPa), observou-se aumento dos valores de resistência à tração da união, com significância estatística. Quanto ao tipo de falha, observou-se que: Eversoft apresentou maior porcentagem de falha adesiva e mista. Já, a base resiliente Softliner, apresentou 100% de falha adesiva. Para o ensaio de deformação permanente, independente do tratamento recebido, o material Eversoft apresentou o valor mais elevado (2,27%) e diferiu estatisticamente do Softliner (0,38%). A termociclagem promoveu a elevação gradativa da porcentagem de deformação permanente apenas para o material à base de resina acrílica, diferindo estatisticamente a partir dos 1500 ciclos térmicos (1,88%) e respectivamente nos grupos dos 2000 (2,19%), 2500 (2,57%), 3000 (2,85%) e 3500 ciclos (3,24%). O grupo dos 4000 ciclos (3,45%) não apresentou diferença estatística significativa se comparado com o dos 3500 ciclos / Abstract: The purpose of this study was to evaluate the effect of thermal cycling on the tensile bond strength and the permanent deformation of two soft denture liner materiaIs (one silicone - Softliner and one acrylic resin - Eversoft). In the first study (tensile bond strength), one acrylic resin (QC-20) for denture base was used. For each study was used 200 samples divided in 10 groups, with 10 samples for each material: group I - not thermocycled (control group); group II- 200 cycles; group III - 500 cycles; group IV - 1000 cycles; group V - 1500 cycles; group VI ¿ 2000 cycles; group VII - 2500 cycles; group VIII - 3000 cycles; group IX - 3500 cycles and group X - 4000 cycles. The thermal cycling was made in the machine MSCT-3 plus where cycles of 1 minute in water at 5°C (± l°C) and 1 minute of water at 55°C (± l°C) were made. For the making of the samples, metallic dies (40 x 10 x 10 and 13 x 19 mm) were used invested in flasks, whose model impressed in the silicone of the condensation and in the gypsum was filled up with acrylic resin and/or soft materiaIs. After each period, the samples of the first study were submitted to a tensile bond strength test in a universal testing machine (EMIC DL-500 MF) at the crosshead speed of 5 mm / minute. The samples of the second study were submitted to a permanent deformation test in a mechanic machine described in the A.D.A.' s specification nº 18. The obtained results were submitted to the variance analyses (ANOVA) and to the Tukey' s Test, at the leveI of 5% of probability and the tensile bond strength samples were analyzed according to the kind of failure occurred. Based in the results of the tensile bond strength study, the Softliner material submitted to the thermal treatments didn't presented values of the bond strength with statistical difference, however Eversoft presented a significant statistical difference in the control group (0.47 MPa) and the group of the 500 cycles (0.46 MPa) when compared with the group of the 4000 cycles (0.70 MPa). The Eversoft material presented adhesive and mixed failures. The Softliner material presented 100% of adhesive failures. Based in the results of the permanent deformation study, when we observe the averages of the values independent the treatment was used, the Eversoft material presented the highest values (2.27%) and the Softliner presented the lowest (0.38%). To the acrylic resin soft denture material the thermal cycling increased the values of permanent deformation, however were observed a significant statistical difference only after the group of 1500 cycles / Doutorado / Protese Dental / Doutor em Clínica Odontológica
23

Movimentação dental linear em protese total superior em função dos materiais de inclusão e metodos de polimerização

Boscato, Noeli 02 August 2018 (has links)
Orientadores : Saide Sarckis Domitti, Simonides Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-02T19:35:31Z (GMT). No. of bitstreams: 1 Boscato_Noeli_M.pdf: 1495029 bytes, checksum: c863e45b8ffda144f65c6b53a089e4e9 (MD5) Previous issue date: 2002 / Mestrado
24

Avaliação do arco gotico de Gysi e da atividade eletromiografica computadorizada bilateral dos musculos masseter e temporal anterior, em pacientes portadores de proteses totais superiores

Lisboa, Jose Augusto Ataide 18 June 2003 (has links)
Orientador: Frederico Andrade e Silva / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T17:10:46Z (GMT). No. of bitstreams: 1 Lisboa_JoseAugustoAtaide_D.pdf: 6829620 bytes, checksum: 7203c2b2fda77f4b780bcc0df088535b (MD5) Previous issue date: 2003 / Resumo: Muitas vezes, pacientes reabilitados com próteses totais acabam desenvolvendo alterações funcionais do sistema estomatognático, muito embora possam parecer assintomáticos. Neles, podem ser detectadas alterações nas atividades dos músculos relacionados com a mastigação e, como conseqüência, também alterações na cinética dos côndilos durante os movimentos mandibulares. Essas alterações podem ser perpetuadas e/ou agravadas, se uma correta conduta clínica não for efetivamente realizada para normalizar a atividade funcional dos músculos, previamente à reabilitação. O tratamento com aparelhos oclusais planos previamente à reabilitação protética, foi instituído para harmonizar a atividade muscular e a cinética condilar. O arco gótico de Gysi foi obtido antes e após o tratamento com aparelhos oclusais planos e a reabilitação protética de cada um dos pacientes. Em seguida, os pacientes foram submetidos a uma avaliação eletromiográfica computadorizada dos músculos temporal anterior e masseter. A avaliação do arco gótico de Gysi mostrou que, após o tratamento, ocorreu um aumento na amplitude do mesmo, tanto durante os movimentos lateroprotrusivo como protrusivo, assim como, uma redução no desvio da linha média. A análise eletromiográfica mostrou não haver diferença estatisticamente significante para o músculo temporal anterior e masseter / Abstract: The oral rehabilitation needs a great sum of knowledge for the obtain of the functional and aesthetic success, which is the purpose of ali the efforts, during the clinical procedures. A lot of times, patients rehabilitated with total prostheses end up developing functional alterations of the stomathognatic system, althought they show no signs, their alterations can be detected in the activities of the muscles related with the mastication, and as consequence, also alterations in the kinetics of the condile during the mandibular movements . These alterations can be perpetuated and/or worsened, if a correct clinical conduct is not accomplished to normalize the functional activity of the muscles previously to the rehabilitation. The treatment with oclusal plane splints previously the prosthetic rehabilitation was instituted to harmonize the muscular activity and the kinetic condylar. The gothic arch tracing was obtained before and after the treatment with splints and prosthetic rehabilitation of each one of the patients. Soon afterwords, the patients were submitted to computerized electromyographic evaluation of the anterior temporalls and masseter muscles. The evaluation of the gothic arch tracing showed that after the treatment happened an increase in the amplitude of the same amount during the movements lateroprotrusive and protrusive, as well as a reduction in the deflection of medium line. The electromyographic analysis showed there were no significant difference between anterior temporalls and masseter muscle / Doutorado / Protese Dental / Doutor em Clínica Odontológica
25

Efeito de um limpador de protese na concentração de compostos sulfurados volateis e na microbiota bucal de pacientes idosos institucionalizados portadores de proteses totais

Oliveira, Viviane Maia Barreto de 11 November 2003 (has links)
Orientadores: Altair A. Del Bel Cury, Pedro Luiz Rosalen / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T18:53:40Z (GMT). No. of bitstreams: 1 Oliveira_VivianeMaiaBarretode_D.pdf: 3110818 bytes, checksum: 40e9aa33bfe2bfa6fd45609e4b286025 (MD5) Previous issue date: 2003 / Resumo: O objetivo deste estudo foi verificar a eficácia do limpador de prótese Polident 5 minutes@ (Block and Drug Corp.) quanto à redução da concentração de Compostos Sulfurados Voláteis (CSV), por meio do Halimeter@ (Interscan Corp.) e a ação bactericida pela cultura microbiana em ágar sangue e MacConkey, além de avaliar a correlação entre a habilidade em higienizar as próteses (HA) e o índice de biofilme (IB) sobre as mesmas. Foram selecionados 19 voluntários, com idades entre de 62 a 86 anos, portadores de pelo menos prótese total superior. As análises foram realizadas em duas fases (F). FI: avaliação m e verificação HA, determinação da concentração de CSV e coleta do biofilme das próteses antigas, nos tempos To (sem uso do limpador), TI, T2eT3 (uso contínuo do limpador por 7, 14 e 28 dias); FII: novas próteses foram instaladas, a concentração de CSV foi determinada e o biofilme foi coletado após 30, 60 e 90 dias de uso contínuo do limpador (Tu, T2.2, T3.3). Os resultados para a concentração de CSV apresentaram diferença estatística entre os períodos Toe TI, e Tu e T 2.2, verificada pelo 64, 67A; T3.3: 53,67B. Na avaliação de microrganismos crescidos em aerobiose os resultados não mostraram diferença estatística significativa na FI e na F 11 houve diferença estatística entre todos os tempos, verificada pelo Teste T pareado (p<0,05): To: 3,34a; TI: 2,22a; T2: 2,92a; T3: 4,24a; Tu: O, 14c; T2.2: 1,12B; T33: 2,74B. Concluiu-se que houve uma correlação positiva entre a HA e m, que o limpador não foi eficaz na remoção do biofilme aderido à prótese antiga e não impediu a formação de biofilme nas novas próteses, assim como não reduziu os níveis de CSV dos pacientes / Abstract: The purpose of this study was to determine the effectiveness of the Polident 5 minutes@ (Block and Drug Corp.) denture cleanser in reducing V olatile Sulphur Compounds (VSC) concentration, estimated by Halimeter@ (Interscan Corp.) and the bactericide action by Blood Ágar and MacConkey culture, besides evaluating the correlation among the denture cleaning dexterity (DC) and the biofilm index (BI). 19 volunteers were selected with age range 62 to 86 years, wearing at least the upper denture. The analysis was conducted in two phases (P): PI: BI evaluation, volunteers DC, determination of VSC concentration and the biofilm was collected ITom the old denture before the use of the treatment protocol (To), and after 7, 14 and 28 days of continuous cleanser use (TI, T2 and T3); Pu: new denture was installed, VSC concentration was determinated and biofilm was collected at 30, 60 and 90 days with daily use ofthe denture cleanser (Tu, T2.2, T3.3). The VSC concentration results showed statistical difference between To and results did not show statistical difference at Phase I and, at Phase 11, there was statistical difference between alI the times, by paired-T test (p<0.05): To: 3,343; TI: 2,223; T2: 2,923; denture cleanser was not efficient to remove the old denture biofilm, did not prevent the new denture biofilm and did not reduce patients VCS levels / Doutorado / Protese Dental / Doutor em Clínica Odontológica
26

Avaliação eletromiografica da eficiencia de duas tecnicas de montagem de dentes artificiais em protese total dupla / Electomyographic evaluation of the efficiency ot two prosthetic teeth arrangement techniques in double complete dentures

Ferreira, Daniel Filgueiras 21 February 2005 (has links)
Orientador: Marcelo Ferraz Mesquita / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-04T05:56:39Z (GMT). No. of bitstreams: 1 Ferreira_DanielFilgueiras_M.pdf: 1227737 bytes, checksum: 8574e46d80b04a8d94d10a74cac5fef3 (MD5) Previous issue date: 2005 / Resumo: O objetivo desta pesquisa foi avaliar eletromiograficamente o padrão de atividade muscular resultante da utilização de duas técnicas de montagem de dentes artificiais para obtenção de equilíbrio em prótese total dupla. Vinte e quatro pacientes totalmente edêntulos, livres de sinais e sintomas de Desordem Temporomandibular (DTM) com no mínimo cinco anos de uso de próteses totais, foram separados em dois grupos de 12 pacientes: (G1 e G2). Para o G1, utilizou-se a técnica Convencional, onde o equilíbrio foi obtido através de contatos interferentes entre dentes artificiais. Para o G2, utilizou-se a técnica das Rampas Posteriores de Nóbilo, que proporciona equilíbrio através de contatos deslizantes entre a superfície das rampas. O padrão de atividade muscular foi mensurado através da atividade eletromiográfica (EMG) dos músculos temporais porção anterior e masseteres nas posições de repouso (R) e na contração isométrica em máxima intercuspidação (CIMI), avaliado em quatro tempos: T0 - instalação; T1 - 1o mês; T2 - 2o meses; T3 - 3o meses de uso das próteses. Foi utilizado o eletromiógrafo Myosystem I® (Prosecon Ltda, Uberlândia, MG, Brasil) e o sinal eletromiográfico condicionado através de filtro digital passa faixa e analisado em relação RMS (Root Mean Square). Em ambos os grupos, observou-se pequenas alterações nos valores da atividade EMG para os músculos temporais anteriores e masseteres na posição de R. Na posição de CIMI, no G1 os músculos temporais anteriores apresentaram valores finais menores que os iniciais, e situação inversa foi observada para os masseteres, com valores finais maiores que os iniciais; no G2 observou-se inversão dos valores para os músculos temporais anteriores e aumento para os masseteres com ligeiro equilíbrio no terceiro mês de avaliação. O teste Wilcoxon-Mann-Whitney entre as técnicas e o de Friedman nos tempos avaliados não mostraram diferenças estatísticas significativas (p<0.05). Conclui-se que as técnicas estudadas clinicamente não apresentaram diferença entre si, e que as avaliações nos tempos não proporcionaram o equilíbrio dos músculos mastigatórios estudados. Dessa forma, ambas técnicas podem ser utilizadas com performances clínicas semelhantes / Abstract: The aim of this study was to evaluate by the electromyography muscular activity pattern resulting of two prosthetic teeth arrangement techniques that promote balance in double complete dentures. Twenty-four subjects totally edentulous, free from signs and symptoms of TMJ disorders and with at least five years complete dentures use were divided in two groups of 12 subjects: G1 and G2. In the Group 1, the Conventional technique was used and the interference contacts between artificial teeth were responsible for the balance. In the Group 2, the Nóbilo's Balancing Ramps technique, slippery contacts between ramps surfaces provided balance. The muscular activity pattern was measured by electromyographic (EMG) activity of anterior temporal and masseter muscles in the mandibular rest (R) and maximal biting in the intercuspal position (CIMI) at four times: T0 - installation; T1 - 1st month; T2 - 2nd month; T3 - 3rd month of prostheses use. The electromyographic sign was collected with Myosystem I® conditioned through of digital filter pass band and analyzed in relation to RMS (Root Mean Square). In both groups, in the mandibular rest of the anterior temporal and masseter muscles was observed small alterations in the EMG activity values. In CIMI position, in the Group 1, anterior temporal muscles showed final values smaller than the initial, differently of masseter muscles that showed final values greater than the initial; in the Group 2 inversion values were observed in the temporal muscles and increase in the masseter with light balance in the third month evaluation. Wilcoxon-Mann-Whitney test between the techniques and the Friedman test in the evaluated times did not show significant statistical differences (p<0.05). The techniques clinically studied did not show differences between themselves and the times evaluation did not provide balance in the masticatory muscles studied. In this way, both techniques can be used with similar clinic performance / Mestrado / Protese Dental / Mestre em Clínica Odontológica
27

Recuperação da difusão fonetica em individuos desdentados com emprego de proteses totais duplas confeccionadas com base na tecnica da zona neutra

Pomilio, Arnaldo 09 February 1994 (has links)
Orientador: Moustafa Mohamed El-Guindy / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-19T06:27:10Z (GMT). No. of bitstreams: 1 Pomilio_Arnaldo_M.pdf: 3030641 bytes, checksum: 4b9e0f2ff868ff282bd42846fbd7ce39 (MD5) Previous issue date: 1993 / Resumo: Embora o estudo da fala relacionada aos pacientes desdentados e reabilitados com Prótese Total Dupla possua vários trabalhos publicados, ainda não é considerado com a devida importância que merece, tanto em seu aspecto fisiológico como social e emocional. Utilizando Espectrografia foi analisada a intensidade dos sons da consoante "S" e das vogais "A", "E", "I" e "O" em 5 indivíduos brasileiros, do sexo masculino, com faixa etária de 40 a 76 anos, que nunca se utilizaram de prótese dental e que procuraram a Clinica de Prótese Total da Faculdade de Odontologia da Pontifícia Universidade Católica de Campinas, para confeccionar dentaduras duplas. Trés espectrogramas foram feitos para cada indivíduo: um antes da instalação das dentaduras, outro 30 dias após o uso das mesmas e outro imediatamente após a remoção destas próteses. Aplicou-se aos dados obtidos análise estatistica de média das diferenças, desvio padrão e variância. A significância foi testada por meio do teste t. Como resultado obtldo da amostra estudada, determinamos que os valores de intensidade de som, na situação desdentado, reabilitado ou quando a prótese é removida, apresentam alterações estatisticamente signlficantes, agindo diretamente na qualidade da fala / Abstract: Although several studies have been published about toothless patients rehabilitated with Double Total Prosthesis, this subject has not yet been fully considered as to its physiological, social or emotional aspects. By means of Spectrography, the intensity of sound of the consonant "5" and of the vowels "A", "E", " I" , and "O" was analyzed in five Brazilian male individuals, ages ranging from 40 to 76, who had never made use of dental prosthesis before and who had sought the Total Prosthesis Clinic of the Odontology College at Pontificia Universidade Católica de Campinas to have double dentures made. Three spectrograms were made for each individual: one before the dentures were set, one after 30 days of their use, and another immediately after their removal. A statistic analysis of differences average, standard deviation and variation was applied to the data obtained. Significancy was tested through Teste t. From the studied sample we found that the values concernlng sound intensity in the three different conditions toothless, rehabilitated and after prosthesis removal - show statlstically significant alterations, directly interfering with the quality of speech / Mestrado / Fisiologia e Biofisica do Sistema Estomatognatico / Mestre em Ciências
28

Influencia de tecnicas de polimerização sobre adaptação das bases de protese total

Almeida, Maria Helena Waack de 30 April 1998 (has links)
Orientadores: Saide Sarckis Domitti, Simonides Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-23T15:36:03Z (GMT). No. of bitstreams: 1 Almeida_MariaHelenaWaackde_M.pdf: 4543291 bytes, checksum: e498330720bead407e49365e84feda17 (MD5) Previous issue date: 1998 / Resumo: O objetivo desta pesquisa foi verificar as alterações de adaptação das bases de prótese total, confeccionadas com resina acrílica ativada termicamente, ocorridas sob a influência de 3 técnicas de polimerização: convencional, por calor seco e por energia de microondas. Foram confeccionados 30 modelos padrões em gesso pedra, a partir de um molde de borracha representando uma arcada superior desdentada normal. Sobre os modelos foram confeccionadas as bases de prova, que foram divididas aleatoriamente em 3 grupos de 10 elementos e incluídos. em mufla pela técnica convencional, a fim de receber os seguintes tratamentos experimentais: Grupo 01: prensagem com resina termopolimerizável (Clássico) e polimerização em banho de água aquecida a 74+2°C por 9 horas (método convencional). Grupo 02: prensagem com resina termopolimerizável (Clássico) e polimerização por calor seco (estufa) a 74+2°C por- 9 horas. Grupo 03: prensa$em com resina termopolimerizável (Acron MC) e polimerização em forno de microondas a 900 W por 3 minutos. A seguir, as bases em resina, limpas e acabadas, foram fixadas em seus respectivos modelos com adesivo instantâneo (Super Bonder). O conjunto base de prótese modelo de gesso foi posicionado e fixado em um aparelho específico para obtenção das secções. Orientados por .guias existentes na mesa de fixação, com auxílio de serra manual, foram executados 3 cortes látero laterais passando pela região correspondentes à distal de caninos direito e esquerdo (A), mesial de primeiros molares direito e esquerdo (B) e região "pos-dam" (C) e 3 cortes ântero-posteriores passando pela região correspondente à crista do rebordo direito (A) e esquerdo (C) e região mediana do palato (B). A alteração dimensional ocorrida na resina acrílica foi avaliada por meio de um microscópio comparador, em 5 pontos referenciais para cada tipo de corte. Os resultados numéricos obtidos foram submetidos à análise estatística e as médias ao Teste de Tukey ao nível de significância de 5%. Todas as técnicas avaliadas produziram distorções, sem diferença estatisticamente significante. Quando o desajuste foi analisado dentro de uma mesma técnica, verificou-se que no Grupo 01 (Termopolimerizadora) não houve diferença estatisticamente significante entre os cortes látero-laterais. Entretanto, no Grupo 02 (Estufa), o corte A foi semelhante ao B e o B ao C, enquanto no Grupo 03 (Microondas), os dados demonstraram o mesmo comportamento estatístico entre os cortes B e C, porém diferentes do A, que mostrou a melhor adaptação. Por outro lado, quando os cortes ântero-posteriores foram analisados, houve comportamento estatístico semelhante entre eles nas 3 técnicas de polimerização estudadas. Neste caso, o corte B foi diferente estatisticamente dos cortes A e C, mostrando o maior desajuste. Independente da técnica de polimerização e da localização dos cortes; não houve diferença estatística quando se comparou os índices de desajuste entre os cortes látero-Iaterais e ântero-posteriores / Abstract: The purpose of this study was to veri1)1 the denture bases accuracy, made with heat-cured acrylic resin, occurred under the influence of three cycles of polymerization: conventional, by dry heat and with microwave. energy. Thirty master cast were made in stone plaster from a rubber cast, representing a normal nondental arch. The experimental bases were made on the casts which were divided at randon into three groups of ten elements and included in flask by conventional technique in order to receive the following experimental treatments: Group 01: press with thermicpolymerized resin (Clássico) and polymerized with hot water bath at 74+2°C during 9 hours (conventional method). Group 02: press with thermic-polymerized resin (Clássico) and polymerized with dry heat (oven) at 74+2°C during 9 hours. Group 03: press with thermicpolymerized resin (Acron MC) and polymerized in microwave oven at 900 W during 3 minutes. Afterly the bases in clean and tlnished resin were atlxed on their casts with instantaneous adhesive. The plaster model-prosthesis bases set was positioned and atlxed on an especitlc instrument to obtain the sections. Guided by instruments on tlxation grip, with the aid of a manual saw, three saggital plane cuts were made on the corresponding region to the right crest of ridge (A) and left (C) and on the palatal median region (8) and 3 lateral plane cuts corresponding to the distal of right and left canines (A), right and left tlrst molars mesial (8) and pos-dam region (C). The occurred dimensional alteration on the acrylic resm was evaluated with a comparator microscope in 5 referential points to each kind of cut. The numerical results were submited to a statistical analysis and the averages by the Tukey Test to a significance levei of 5%. AlI the evaluated techniques caused distortions, without statistical significative difference. There wasn't any statistical significative difference on the sagittal plane and lateral plane cuts among the three studied polymerization techniques. When the disadjustement was analysed within the same techniques, it was verified that in Group 01 (thermicpolymerizer) there was no statistical significative difference among the lateral plane cuts. However, in group 02 (Oven), the cut A was similar to B and B to C and in group 03 (Microwaves) the datas showed the same statistical conduct between cuts B and C, but different from cut A, which showed the best adaptation . On the other hand, when the sagittal plane cuts were analys~d, there was a similar statistical conduct among them on the three studied polymerization techniques. In this case, the cut B was statisticalIy different from cuts A' and C, showing the biggest disadjustment / Mestrado / Protese / Mestre em Clínica Odontológica
29

Influencia da tecnica de caracterização intrinseca sobre a dureza, rugosidade superficial e porosidade de uma resina acrilica em diferentes tempos pós-prensagem

Almeida, Marco Antônio Borges de 04 September 2001 (has links)
Orientador: Marcelo Ferraz Mesquita / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-27T22:44:32Z (GMT). No. of bitstreams: 1 Almeida_MarcoAntonioBorgesde_M.pdf: 5917806 bytes, checksum: 9fe425ba0979361a5689e9725739a1d5 (MD5) Previous issue date: 2001 / Resumo: O objetivo deste estudo foi avaliar a influência da técnica de caracterização intrínseca sobre a dureza, rugosidade superficial e ocorrência de porosidade de uma resina acrílica ativada termicamente em forno de microondas em diferentes tempos pós-prensagem (1/2, 2, 6, 12 e 24 horas). Foram confeccionadas 270 amostras em resina acrílica, sendo metade produzida pela técnica convencional com resina incolor (M1) e metade pela técnica de caracterização intrínseca (M2). Todas as amostras foram polimerizadas em forno de microondas em ciclo de 6 minutos a 40% de potência, intervalo de 5 minutos a 0% de potência e 3 minutos a 80% de potência. Após a polimerização as amostras foram desincluídas e receberam acabamento e polimento padronizado. Foram realizados ensaios de dureza Knoop em um microdurômetro HM V-200O (SHIMADZU), rugosidade superficial em um rugosímetro SURFCORDER SE 1700 (KOSAKA LAB) e verificada a ocorrência de porosidade em uma lupa estereoscópica MG 63A (CARL ZEISS). Além disso foram realizadas observações em microscopia eletrônica de varredura da morfologia superficial das amostras e das fibras de caracterização. Os dados obtidos foram analisados estatisticamente por Análise de Variância e pelo Teste F. Os resultados médios obtidos para dureza Knoop (KHN) e rugosidade superficial (JJm), parâmetros Ra e Rz, foram para o Grupo M1: 18,25; 0,0587 e 0,3474 e para o Grupo M2: 18,04; 0,0795 e 0,5375, respectivamente. A análise dos resultados permitiu concluir que: não houve influencia do tempo pós-prensagem sobre as propriedades estudadas; a dureza superficial da resina acrílica caracterizada foi estatisticamente semelhante à da incolor obtida de modo convencional; os valores de rugosidade superficial média da resina caracterizada foram superiores aos da incolor; a ocorrência de porosidade foi desprezível em todos os grupos avaliados / Abstract: The aim of this study was to evaluate the influence of the intrinsic characterization technique on hardness, surface roughness and porosity of a microwave cured acrylic resin in different post packing and press periods (1/2, 2, 6, 12 and 24 hours). 270 samples of acrylic resins were prepared. Half of them were prepared by the conventional technique using clear resin (M1) and the other half by the intrinsic characterization technique (M2). Ali samples were cured in a microwave oven in cycle of 6 minutes at 40% potency, 5 minutes at 0% potency and 3 minutes at 80% potency. After cured the samples were deflasked, finished and polished. Knoop microhardness assay was performed in a microhardness teste r HM V-200O (SHIMADZU), surface roughness assay was conducted in a profilometer SURFCORDER SE 1700 (KOSAKA LAS) and the occurrence of porosity was verified by means of a stereoscopic magnifying glass MG 63A (CARL ZEISS). In addition, scanning electron microscopy was used to observe the surface texture of the samples and characterization fibers. ANOVA and F-test statistically analyzed the data. The mean results of Knoop hardness (KHN), surface roughness Ra and Rz parameters (j.Jm) were: 18,25; 0,0587 and 0,3474 in M1 Group and 18,04; 0,0795 and 0,5375 in M2 Group, respectively. Based on the results analysis it was concluded that: post packing and press periods did not influence the studied properties; the surface hardness of the characterized acrylic resin was similar to the surface hardness of the clear acrylic resins; the mean values of surface roughness of the characterized acrylic resin were higher than those of the clear acrylic resin; the occurrence of porosity was negligible in ali evaluated groups / Mestrado / Protese Dental / Mestre em Clínica Odontológica
30

Estudo comparativo do registro da guia condilar atraves dos metodos desgaste de Paterson e registro intra-oral de Nobilo. Correlação com a inclinação da eminencia articular por tomografia linear

Trindade, Marilene de Oliveira 30 January 2001 (has links)
Orientador: Mauro Antonio de Arruda Nobilo / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T04:51:40Z (GMT). No. of bitstreams: 1 Trindade_MarilenedeOliveira_D.pdf: 2667807 bytes, checksum: 5f5365440f1052e0d38e7affcf6aa49a (MD5) Previous issue date: 2001 / Resumo: O objetivo deste trabalho foi comparar os valores angulares obtidos por dois métodos de registro das trajetórias condilares, Desgaste de Paterson e Registro Intra-Oral de Nóbilo com a inclinação da parede posterior da eminência articular através da tomografia linear de pacientes desdentados completos. Foram avaliados 12 pacientes desdentados totais, com idade variando entre 39 e 73 anos e que não apresentavam sinais e sintomas clínicos de desordens temporomandibulares. Os pacientes foram submetidos ao registro das relações maxilomandibulares através dos métodos de Desgaste de Paterson e Registro Intra-oral de Nóbilo. O primeiro consistia da individualização das curvas oclusais pelo esmerilhamento de abrasivos incorporados a roletes de godiva em bases de prova. O segundo método consistia de dispositivo intra-oral formado por duas plataformas sendo uma composta de pua registradora e outra de disco metálico. Alem disto, as plataformas possuíam entalhes vestibulares que permitiam a fixação de posições mandibulares de interesse protético. Após os registros, os modelos foram montados em articulador semi-ajustável (Dentatus ARL-P) e registradas as guias condilares ântero-posteriores. Em seguida, os pacientes foram submetidos a exames de tomografia linear referentes à parede posterior da eminência articular, para isso foi utilizado o aparelho tomográfico (Denar Quit Sectograph). Foram obtidas as medidas angulares com o auxílio de um transferidor plástico de Bimler. Os dados obtidos foram submetidos à análise de variância e as médias ao teste t ao nível de 5% de significância. As médias das inclinações condilares para o lado direito e tomografia linear (45,5°) foram superiores aos métodos de Nóbilo (31,58°) e Paterson (23,25°) que diferiram estatisticamente entre si. ... Observação: O resumo, na íntegra, poderá ser visualizado no texto completo da tese digital / Abstract: The purpose of this work was to study the angular values obtained through two different methods for registering condylar paths: that of Paterson's Register of Wear and Nobilo's Intra-Oral Register with the inclination of the posterior surface of the articular eminence through linear tomography. Twelve completely edentulous patients were evaluated, with ages ranging from 39 to 73, that did not present any signs or clinical symptoms of temporal-mandibular disorders. The patients were submitted to registers of maxillo-mandibular relationships through the methods proposed in Paterson's Register of Wear and Nobilo's Intra-Oral Register. The first method consisted of making individualized occlusal curvatures through abrasive wastage incorporated in compound rollers in denture bases. The second method consisted of creating an intra-oral device made up of two platforms, with one having a screw with a needle point attached to it and the other having a metallic disc attached. Moreover, the platforms had vestibular jongs which made it possible to fix mandibular positions that could prove interesting, trom a prosthetic's point of view. After the registers had been made, models (cast moulds) were mounted on a semi-ajustable articulator (Dentatus ARL-P) and the anterior-posterior condylar guides were registered. After that, the patients were submitted to exams of the posterior surface of the articular eminence using linear tomography, and in order to carry out these exams the Denar Quit Sectograph equipment was used. Angular measures were obtained through the use of a Bimier plastic protractor. The results obtained were analyzed with regards to variations and the averages were submitted to the t-test at a levei of 5% of significance. The averages of the condylar inclinations for the right side as measured through linear tomography (45.5°) were higher than those obtained through the methods presented by Nobilo (31.58°) and by Paterson (23.25°), and the latter two presented statistical variations between each other. ... Note: The complete abstract is available with the full electronic digital thesis or dissertations / Doutorado / Protese Dental / Doutor em Clínica Odontológica

Page generated in 0.1188 seconds