• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 56
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 59
  • 59
  • 59
  • 23
  • 22
  • 20
  • 19
  • 18
  • 13
  • 13
  • 11
  • 9
  • 7
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Efeito da combinação de gessos de inclusão sobre a adaptação das bases de protese total superior

Almeida, Maria Helena Waack de 02 December 2001 (has links)
Orientadores : Saide Sarckis Domitti, Simonides Consani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T05:33:00Z (GMT). No. of bitstreams: 1 Almeida_MariaHelenaWaackde_D.pdf: 5508767 bytes, checksum: b03c3c13c9774dfa80be1f7537d1c28d (MD5) Previous issue date: 2001 / Resumo: O objetivo desta pesquisa foi verificar os efeitos da combinação de gessos de inclusão na adaptação das bases de prótese total superior, confeccionadas com resina acrílica ativada termicamente, polimerizadas de acordo com os seguintes ciclos: convencional, calor seco e energia de microondas. Foram confeccionados quarenta e cinco modelos padrões em gesso pedra, a partir de um molde de borracha representando uma arcada superior desdentada. Sobre os modelos foram confeccionadas quarenta e cinco bases de prova, divididas aleatoriamente em três grupos de quinze elementos cada, baseados no tipo do gesso utilizado durante a fase de inclusão dos modelos. No Grupo l, as bases de prova foram incluídas em mufla pela técnica convencional, utilizando-se gesso comum e pedra. No Grupo lI, utilizando-se gesso comum e especial, e no Grupo III, gesso pedra e especial. Cada Grupo foi subdividido em três subgrupos, de acordo com o ciclo de polimerização ao qual as amostras foram submetidas: Subgrupo 1: polimerização através do ciclo convencional (74+2°C por 9 horas); Subgrupo 2: polimerização por calor seco (74+2°C por 9 horas); e Subgrupo 3: polimerização através de energia de microondas (900 W por 3 minutos). A seguir, as bases em resina foram fixadas em seus respectivos modelos com adesivo instantâneo. O conjunto base de prótese-modelo de gesso foi posicionado, fixado e seccionado em aparelho específico onde foram executados três cortes látero-Iaterais: A (anterior), B (médio) e C (posterior). A alteração dimensional ocorrida na resina acrílica foi avaliada por meio de um microscópio comparador, em cinco pontos referenciais. Os resultados numéricos foram submetidos à análise de 1 variância e ao teste de Tukey (5%). Concluiu-se que, independente dos demais fatores, o ciclo convencional mostrou o maior desajuste das bases de prótese em relação aos modelos. Quando o tipo de inclusão foi analisado em relação ao fator ciclo de polimerização, verificamos que as inclusões Comum/Especial e Pedra/Especial não apresentaram valores com diferença estatística significativa. Na inclusão Comum/Pedra o ciclo convencional apresentou o maior desajuste. Quando o fator corte foi analisado em função do ciclo de polimerização, notamos que no corte A, o ciclo convencional apresentou o maior desajuste. Quando os cortes foram analisados independente de outros fatores, houve diferença estatística significativa entre eles. O maior desajuste ocorreu no corte C. Quando os cortes foram analisados em relação ao tipo de inclusão independente de outros fatores, verificamos que nas inclusões Comum/Especial e Pedra/Especial, o maior desajuste ocorreu no corte C. Quando o tipo de inclusão foi observado independente de outros fatores, verificamos que a inclusão Comum/Pedra apresentou o menor desajuste / Abstract: he purpose of this study was to verify the effects of the combination of inclusion plaster in the adaptation of upper denture bases, made with heat-cured acrylic resin, ocurred under the influence of three cycles of polymerization: conventional, by dry heat and with microwave energy. Forty-five master casts were made in stone plaster from a rubber cast representing upper nondental arch. The forty-five experimental bases were made on the casts which were divided at randon into three groups of fifteen elements, based on the kind of plaster used during the inclusion phase of the casts. The casts with the experimental bases from Group I were included in flask by conventional technique, using commum plaster and stone. In the Group II, using commum plaster and special, and the Group II stone plaster and special. Each group was subdivided into three subgroups, according the polymerization cycle to which the casts were submitted: Subgroup 1: polymerization through the conventional cycle (74 + 2°e for nine hours). Subgroup 2: polymerization by dry heat (74 + 2° e for nine hours) and Subgroup 3: polymerization in Microwave Oven (900 W for 3 minutes). Next, the bases in resin were fixed on their casts with instantaneous adhesive. The plaster model - prosthesis bases set was positined, fixed and cut on an especific instrument, three lateral plane cuts were made: A (anterior), B (median) and e (posterior). The occurred dimensional alteration on the acrylic resin was evaluated with a comparator microscope in five referential points. The numerical results were submitted to a variance analysis and the Tukey Test (5%). It was concluded that, independent of other factors, the conventional cycle showed the biggest disadjustment of the denture bases in relation to the casts. When the kind of inclusion was analysed in relation to the cycle fa cto r of polymerization, it was verified that the Commum/Special and Stone/Special inclusions did not show statistic significative difference. In the Commum/Stone inclusion the conventional cycle showed the biggest disadjustment. When the cut factor was analysed in relation to the polymerization cycle, it was verified that in the A cut, the conventional cycle showed the biggest disadjustment. When the cuts were analysed independent of other factors, there was significative statistic difference among them. The biggest disadjustment occurred in the C cut. When the cuts were analysed in relation to the kind of inclusion independent of other factors, it was verified that in the Commum/Special and Stone/Special inclusions, the biggest disadjustment occurred in the C cut. When the kind of inclusion was analysed independent of other factors, it was verified that the Commum/Stone inclusion showed the smallest disadjustment / Doutorado / Protese / Doutor em Clínica Odontológica
32

Estudo da atividade eletromiografica e eficiencia mastigatoria e sua correlação em usuarios de proteses totais / Study of electromyographic activity and masticatory performace and their correlation in wearers of double complete denture

Ferreira, Daniel Filgueiras 06 January 2007 (has links)
Orientador: Marcelo Ferraz Mesquita / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-09T19:30:32Z (GMT). No. of bitstreams: 1 Ferreira_DanielFilgueiras_D.pdf: 20631987 bytes, checksum: 0a017286a161e436c081c4f57ace20ab (MD5) Previous issue date: 2007 / Resumo: O objetivo desta pesquisa foi avaliar a eficiência mastigatória, a atividade eletromiográfica (EMG) e sua possível correlação em usuários de próteses totais duplas. Vinte e quatro pacientes totalmente edêntulos, livres de sinais e sintomas de Desordem Temporomandibular (DTM) com no mínimo cinco anos de uso de próteses totais, foram selecionados e separados aleatoriamente em dois grupos de 12 pacientes: (G1 e G2). Os pacientes foram reabilitados com novas próteses de acordo com os grupos. No G1, utilizou-se a técnica Convencional, onde o equilíbrio foi obtido através de contatos interferentes entre dentes artificiais. No G2, utilizou-se a técnica das Rampas Posteriores de Nóbilo, que proporcionou equilíbrio através de contatos deslizantes entre as superfícies das rampas. No terceiro mês de uso das próteses totais, os pacientes tiveram sua eficiência mastigatória avaliada através da trituração de 1,5 g de alimento teste (amendoim), em 15 e 30 ciclos mastigatórios utilizando o método de fracionamento em peneiras. Na mesma época, a atividade EMG dos músculos temporal anterior e masseter foi avaliada nas posições de repouso (R) e de contração isométrica em máxima intercuspidação (CIMI) utilizando o eletromiógrafo Myosystem I'MARC REGISTRADA' (Prosecon Ltda, Uberlândia, MG, Brasil). O sinal eletromiográfico foi condicionado através de filtro digital passa faixa e analisado em relação RMS (Root Mean Square). O teste Anova não mostrou diferenças estatísticas significantes (p<0.05) para as médias praticamente idênticas da eficiência mastigatória entre os grupos 1 e 2 com 15 ciclos mastigatórios e para a pequena diferença com 30 ciclos mastigatórios. Já, o teste de Correlação de Pearson mostrou diferenças estatísticas significantes (p<0.05) na correlação da eficiência mastigatória entre os ciclos dentro de cada grupo, a qual não foi exatamente proporcional ao número de ciclos realizados. A atividade EMG analisada pelo teste Anova não mostrou diferenças estatísticas significantes (p<0.05) entre as pequenas diferenças das médias avaliadas entre os grupos. Conclui-se que as técnicas avaliadas não influenciam na eficiência mastigatória nem na atividade EMG e que a eficiência mastigatória é proporcional ao número de ciclos mastigatórios / Abstract: The aim of this study was to evaluate the masticatory efficiency, the electromyographic (EMG) activity and their possible correlation in wearers of double complete dentures. Twenty-four totally edentulous patients, free from signs and symptoms of Temporomandibular Disorders (TMD) with at least five years use of double complete dentures, were selected and randomly separated into two groups of 12 patients: (G1 and G2). The patients were rehabilitated with new complete denture according to the groups. In G1, the Conventional technique was used, where the balance was obtained through interference contacts among artificial teeth. In G2, the Nóbilo's balancing ramps technique was used, which provided balance through sliding contacts between the surfaces of the ramps. In the third month of use of complete dentures, the patients had their masticatory efficiency evaluated through the comminution of 1.5 g of test food (peanuts), in 15 and 30 masticatory cycles using the sieving method. In the same period, the EMG activity of the anterior temporal and masseter muscles was evaluated in mandibular rest (R) and in maximal biting in the intercuspal positions (CIMI) using the Myosystem I'TRADE MARK' (Prosecon Ltda, Uberlândia, MG, Brazil). The EMG sign was conditioned through digital filter pass band and analyzed in relation to RMS (Root Mean Square). The Anova test did not show significant statistical differences (p<0.05) for the practically identical averages of the masticatory efficiency between the groups 1 and 2 with 15 masticatory cycles and for the small difference with 30 masticatory cycles. On the other hand, the Pearson Correlation test showed significant statistical differences (p<0.05) in the correlation of the masticatory efficiency among the cycles in each group, which was not exactly proportional to the number of accomplished cycles. The EMG activity analyzed by the Anova test did not show significant statistical differences (p<0.05) between the small differences of the evaluated averages between the groups. In conclusion, the evaluated techniques do not influence the masticatory efficiency nor the EMG activity and that the masticatory efficiency is proportional to the number of masticatory cycles / Doutorado / Protese Dental / Doutor em Clínica Odontológica
33

Influencia de diferentes tipos de muflas na movimentação de dentes de proteses totais superiores / Influence of different flask types on teeth displacement in complete upper dentures

Santos, Mateus Bertolini Fernandes dos, 1985- 02 October 2010 (has links)
Orientador: Rafael Leonardo Xediek Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piraciaba / Made available in DSpace on 2018-08-15T04:23:57Z (GMT). No. of bitstreams: 1 Santos_MateusBertoliniFernandesdos_M.pdf: 2329758 bytes, checksum: 359af0abc873ef75f6b0cf7077d9a714 (MD5) Previous issue date: 2010 / Resumo: O objetivo neste estudo foi verificar a influência de diferentes tipos de muflas na movimentação de dentes ocorrida em próteses totais padronizadas após o processamento laboratorial em ciclo de polimerização longo (74±2°C por 9 horas), em banho de água. A partir de matrizes em silicone, foram obtidos 31 modelos em gesso pedra tipo III de uma arcada desdentada superior e 31 de uma inferior. Sobre um modelo superior foram confeccionada base de prova e plano de orientação em cera com dimensões de 20 mm de altura na região anterior e 10 mm na região posterior. Este plano foi montado em articulador semi-ajustável, e após isso foi confeccionada base de prova e plano de cera inferior seguido pela montagem do modelo inferior no articulador. Após a realização da montagem dos dentes artificiais nos planos de cera, foi confeccionada uma matriz em silicone laboratorial para possibilitar a reprodução da montagem dos dentes. Foram então encerados 30 pares de próteses totais, distribuídos aleatoriamente em três grupos (n=10): Mufla convencional, Mufla Dupla e Mufla HH com os dentes em oclusão. Antes da inclusão pinos referenciais foram colocados em locais padronizados e as distâncias entre incisivos (I-I), pré-molares (P-P), molares (M-M), incisivo a molar do lado esquerdo (IE-ME) e incisivo a molar do lado direito (ID-MD) aferidas em microscópio óptico linear com 0,0005 mm de precisão. Após a polimerização estas distâncias foram aferidas novamente, e os dados obtidos analisados estatisticamente através dos testes t-pareado, ANOVA e Holm-Sidak, todos com 95% de confiança. Foram encontradas diferenças estatisticamente significantes entre as distâncias P-P (p=0,003 para mufla dupla; e p<0,001 para mufla HH) e M-M (p=0,006 para mufla convencional; p=0,005 para mufla dupla; e p<0,001 para mufla HH). Quando comparadas entre si, foi encontrada diferença estatisticamente significante entre pré-molares (p=0,011) sendo que a mufla convencional apresentou menor diferença entre as distâncias pré/pós-polimerização que a mufla HH (p=0,003). Todas as muflas envolvidas neste estudo apresentaram diferenças estatisticamente significantes em ao menos uma das distâncias aferidas, sendo que a mufla convencional apresentou os melhores resultados / Abstract: The aim of this study was to verify the influence of different flask types in the teeth displacement after processing standardized complete dentures in long cycle of polymerization in water bath (9 hours at 74°C). Thirty-one superior and thirty-one inferior stone casts of an edentulous arch were poured with type III stone, from a silicone matrix. One superior cast was mounted in a semi-adjustable articulator with wax rim height of 20 mm in anterior region and 10 mm in the posterior, and then the inferior cast was mounted too. After teeth wax-up, silicone matrix were made with laboratory silicone to enable the reproduction of the same wax-up pattern. The dentures were assigned randomly in 3 groups (n=10): Traditional flask, Double Flask and HH flask with teeth in occlusion. Before flasking reference pins were placed in standardized places and the distances between incisive (I-I), pre-molars (P-P), molars (M-M), left incisor to left molar (LI-LM) and right incisor to right molar (RI-RM) were measured in an optical microscope with 0.0005 mm accuracy. After polymerization, these distances were re-measured and the data obtained was statistical analyzed trough paired t-test, ANOVA and Holm-Sidak, all with 95% of confidence level. It was found statistical differences among P-P (p=0.003 for double flask; and p<0.001 for HH flask) and M-M (p=0.006 for traditional flask; p=0.005 for double flask; and p<0.001 for HH flask). When compared, it was found statistical differences among pre-molars (p=0.011) where conventional flask showed minor differences than HH flask (p=0.003). All flask types used in this study presents statistical differences in at least one of the measured distances, being that traditional flask showed better results / Mestrado / Protese Dental / Mestre em Clínica Odontológica
34

Avaliação clinica da formação de biofilme sobre reembasadores em bases de proteses totais submetidas a diferentes metodos de higienização

Rahal, Juliana Saab 03 August 2018 (has links)
Orientador: Marcelo Ferraz Mesquita / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T14:39:58Z (GMT). No. of bitstreams: 1 Rahal_JulianaSaab_D.pdf: 754546 bytes, checksum: 0064d427038108e9a3a75b95790898fe (MD5) Previous issue date: 2003 / Doutorado
35

Influencia de ciclos de polimerização sobre o polimento, rugosidade, porosidade e dureza superficial de resina acrilica QC 20

Borges, Luiz Henrique 15 December 1998 (has links)
Orientadores: Saide Sarckis Domitti, Simonides Consani / Dissertação (Mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-24T14:33:24Z (GMT). No. of bitstreams: 1 Borges_LuizHenrique_M.pdf: 4200895 bytes, checksum: 4ef5ed6f9264f15fa030b9367b082b2f (MD5) Previous issue date: 1998 / Resumo: Este trabalho teve o objetivo de analisar - as condições de polimento, rugosidade, porosidade e dureza superficial da resina acrílica QC-20, sob influência de diferentes ciclos de polimerização. Para a confecção dos corpos-de-prova foram utilizadas três matrizes retangulares de alumínio (65xl0 e 64x9 x 3,5 mm), fixadas com cola super bonder (Loctite) em um suporte de madeira. Em seguida, as matrizes foram moldadas com silicona por condensação para uso. laboratorial, zetalabor, (zhermack spa - Itália, distribuidor no Brasil, labordental Ltda.) e os moldes incluídos em muflas metálicas (DCL n.o 5,5) emuflas com reforço de fibra de vidro (GC), próprias para utilização em fomo.. de microondas. A proporção pó/líquido e mistura, assim como a prensagem da resina acrílica QC 20 foram feitas de acordo com as instruções do fabricante. Após a polimerização nos ciclos ,de água aquecida a 74°C por 9 horas; água em ebulição; e, por energia ',de microondas, e resfriamento em temperatura ambiente, os corpos-de-prova foram removidos das muflas e submetidos aos processos de acabamento e polimento convencional. Posteriormente, os corpos-de-prova foram submetidos aos testes de rugosidade, num Rugosímetro Prazis Rug 3; dureza em um Microdurômetro Future Tech, polimento superficial, utilizando uma lupa estereoscópica (Carl Zeiss), com aumento de 25 vezes e fotografias de áreas pré-determinadas; e porosidade aparente, através da imersão dos corpos-de-prova em tinta Nankin (acrilex) por 2 horas, lavados em água corrente por 10 segundos, e posteriormente contada e fotografada na área previamente determinada. Os 10 resultados obtidos foram submetidos à análise de variância, eao teste de Tukey ao nível de significância de 5%. Os resultados do teste de polimento superficial foram avaliados através da comparação fotográfica. da superficie dos corpos-deprova. Concluiu-se que o método recomendado pelo fabricante não diferiu estatisticamente dos outros métodos em dureza, diferiu estatisticamente de ambos em rugosidade e não apresentou diferença estatística emporosidade. Para a variável polimento convencional, observou-se que as superficies mais lisas e polidas foram devidas ao processamento Tecomendado pelo fabricante, seguidos do ciclo convencional e por energia de microondas / Abstract: The aim of this study was to evaluate the eonditions of polishing, roughness, porousness and surfaee hardness of the aerylie resin QC-20, under the influenee of different eycles of euring. The speeimens eonsisted of three reetangular aluminium matrixes (65 x 10 and 64 x 9 x 3,5 mm) attaehed to a wooden holder by super bonder glue (Loetite). Then the matrixes were printed using a silieone for eondensation for laboratory purposes, zetalabor, (zhermaek sp a - Italy, distributed in Brazil by, labordental ltda) and the molds were included into metal flasks (DCL n° 5,5) and into reinforeed fiberglass flasks (GC), espeeially designed for mierowave oven use. The proportion powder/liquid andmixture as well as pressing of the aerylie resin QC -20 were done following the manufaeture's instruetions. After euring in eyclos hot water (74°C) for 9 hours; boiling water; mierowave energy and eooling in room temperature, the speeimens were submitted to tests of roughness in a praxis (rug-3) roughness gauge; hardness in á hardness gauge future teeh, su~aee polishing using a stereoseopie magnifying glass (earl zeiss), magnifieation of 25 times and photographs of pre determined areas; and aparent porousness by the .immersion of the speeimens into nankin ink (aerilex) for 2 hours, washed .into running water for 10 seeonds and thereafter the porousness was eounted and photographed in the pre determined area. The obtained results were submitted to the statistieal analysis, where it ean be eonclued that the manufaeturer' s reeommended method was no statistieal differenee from the others in hardness, it differed statistieal of both in roughness and it didn't present st:atistieal differenee in porousness. For the eonventional polish, it was observed the flatest surfaces and polished form owed to the processing recommended by the maker, followed by the conventional cycle and for energy of microwaves / Mestrado / Protese / Mestre em Clínica Odontológica
36

Influencia do metodo de polimerização, da espessura da base e da presença de dentes na adaptação de proteses totais superiores

Carrilho, Eduardo 10 July 1999 (has links)
Orientador: Celia Marisa Rizzatti Barbosa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-25T02:25:16Z (GMT). No. of bitstreams: 1 Carrilho_Eduardo_M.pdf: 3925876 bytes, checksum: 6a9b683da2ee5624d5c358caaea42920 (MD5) Previous issue date: 1999 / Resumo: Com o intuito de melhorar a adaptação de próteses totais e, assim, a qualidade de vida dos pacientes, vários autores têm dedicado a vida à pesquisas que visam melhorar ou, pelo menos, minimizar este problema. Diversos são os fatores que podem contribuir para o desajuste, entre eles a espessura, o aumento descontrolado da temperatura de polimerização e até mesmo o método de polimerização. Este trabalho envolveu algumas destas variáveis, como a espessura, o método de polimerização e mais um assunto que se tomou controverso na literatura, a alteração causada pela presença dos dentes. Sessenta e quatro próteses foram confeccionadas, a partir de um modelo fundido em liga de Cobre e Alumínio simulando uma maxila edêntula e divididas em oito grupos com oito amostras em cada grupo; quatro grupos foram polimerizados por banho de água a 74 °C/ 9 hs e 4 por energia de microondas a 500W/ 3 mino Dentro destes quatro grupos, dois grupos foram confeccionados com espessura uniforme de 1 mm e dois, com espessura de 2 mm, e, .ainda dentro destes grupos, dois com a presença de dentes e dois com a ausência de dentes. Foi utilizada a resina Lucitone 550; após a polimerização as próteses recebiam acabamento e eram submetidas a um teste na qual um material de impressão (EXPRESS - 3M) foi interposto entre a base e o modelo de metal e depois pesado. Após o resultado, concluiu - se que: 1) existiu diferença significante para as médias de desajuste entre as duas espessuras, e que a que causou menor desajuste foi a de 2 IDID. 2) Não houve diferença estatisticamente significativa entre as médias de desajustes com ou sem dentes e nem entre os dois critérios de polimerização. 3) O grupo que apresentou menor desajuste foi o de próteses com 2 mm e com a presença de dentes e o que apresentou maior desajuste foi o de próteses com 1 mm e com a presença de dentes / Abstract: With the objetive of improving the adaptation of total prostheses and like this the pattem of the patients' life, several authors have been dedicating the life in researches that seek to improve or at least to minimize this problem. Several factors can contribute to the desadaptation to bases of prostheses, among them are the thickness, the uncontrolled increase of polimerization temperature, and even the polimerization method. The objective of this work was verify the alteration in the adaptation to bases of prostheses with some of these variants like thickness, the polimerization method is one more subject that became controversial in the literature, and the alteration caused by the presence of the teeth. Sixty four prostheses were made, starting from a melted model in alloy of Copper and Aluminum simulating a maxilla and divided in 8 groups with 8 samples in each group, 4 groups were polimerized in baths of water to 74°C / 9 hs and 4 by microwaves energy at 500W / 3 mino ln these 4 groups, 2 had uniform 1 mm thickness and 2 with 2 mm thickness and still inside these groups 2 with the presence of teeth and 2 with the absence of teeth. The resin utilized was Lucitone 550, after the polimerization the prostheses received the fmishing and they were submitted to a test where an impression material was interposed between the base and the metal model and later the heavy one. After the result, the authors conc1uded the following: 1) Signim.cant difference existed in the desadaptation averages between the two thickness, and that the one which caused smaller desadaptation was to of 2 mm. 2) there was no significant statisticaly difference among the desadaptation averages with or without teeth and neither between the two polimerization criteria. 3) the group that presented smaller desadaptation was the prostheses with 2 mm and with the presence of teeth, and the one that presented larger desadaptation was the prostheses with 1 mm and with the presence of teeth / Mestrado / Protese Dental / Mestre em Clínica Odontológica
37

Caracteristicas clinicas de pacientes edentulos e presença de Candida sp. na saliva antes e 6 meses após a confecção de novas proteses totais

Pires, Fábio Ramôa 16 July 1999 (has links)
Orientadores: Marcio Ajudarte Lopes, Oslei Paes de Almeida / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-25T11:10:02Z (GMT). No. of bitstreams: 1 Pires_FabioRamoa_M.pdf: 9940933 bytes, checksum: 4f02a5452eb9e60c99efdb9fe1122e38 (MD5) Previous issue date: 1999 / Resumo: As condições clínicas intra-bucais e radiográficas dos maxilares de 107 pacientes desdentados totais foram analisadas antes da confecção de próteses totais. O fluxo salivar, a quantificação e identificação das espécies de Candida, a presença de mucosite por próteses e os valores de IgA anti Candida salivar, foram avaliados antes e seis meses após a confecção de próteses totais nos pacientes. Foram encontradas alterações clínicas e radiográficas em cerca de 30% dos pacientes, algumas das quais interferiram com o tratamento proposto e necessitaram tratamento prévio. Os valores de fluxo salivar mostraram-se normais em todos os grupos etários, mas foram menores em pacientes do sexo feminino. Níveis mais elevados de Candida na saliva foram encontrados em pacientes com fluxo salivar reduzido, em mulheres e em pacientes com higiene das próteses considerada insatisfatória. Cerca de 80% dos pacientes apresentaram Candida na saliva em ambas as consultas, sendo que a espécie C. albicans representou cerca de 73% das espécies isoladas em ambas as consultas. Cerca de 92% dos pacientes já utilizavam próteses anteriores, dos quais 54 % apresentaram mucosite por próteses na primeira consulta. Seis meses após a confecção das novas próteses, apenas 18% dos pacientes apresentavam mucosite. No entanto, o número de pacientes apresentando Candida na saliva na primeira e segunda consultas foi semelhante, mostrando que embora tenha sido obtida melhora clínica importante, o potencial de recidiva da condição permaneceu bastante alto. Não foi obtida correlação entre os valores de IgA anti-Candida e os níveis salivares de Candida e a presença de mucosite por PTs / Abstract: The clinical intra-oral and panoramic radiographic findings of 107 clinically edentulous patients were studied before complete denture treatment. Also, salivary flow, Candida counts and species, presence of denture stomatitis and salivary anti-Candida IgA values were compared before and 6 months after the introduction of the new complete dentures. Clinical and radiographic findings were founded em about 30% of the patients, some of them interfering with the treatment, claiming for previous management. Salivary flow values were similar in all age groups, but lower in females. Salivary Candida counts were raised in patients with reduced salivary flow, in females and in those with insatisfactory denture hygiene. About 80% of the patients were Candida carriers in both examinations, and C. albicans was responsible for 73 % of the species. Almost 92% of the patients were complete denture users in the first examination, 54% of them showed denture stomatitis. Six months after the introduction of new dentures, only 16% of the patients showed denture stomatitis. However, the number of Candida carriers of the first and in the second examinations were similar, showing that although we have obtained clinical improvement in most of the cases, the denture stomatitis recurrence potential remained high. It was not obtained positive correlation between the values of salivary anti-Candida IgA and salivary Candida counts and presence of denture stomatitis / Mestrado / Biologia e Patologia Buco-Dental / Mestre em Odontologia
38

Efeito da escovação mecanica e da termociclagem sobre dureza e rugosidade superficiais de reembasadores resilientes / Effect of mechanical brushing and ageing by thermal cycling on hardness and roughness surface of resilient soft liners

Hermann, Caio 24 February 2005 (has links)
Orientador: Marcelo Ferraz Mesquita / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-04T03:47:30Z (GMT). No. of bitstreams: 1 Hermann_Caio_M.pdf: 1426714 bytes, checksum: 9b5d60e0226de3bf4200bec3b2f9f1c7 (MD5) Previous issue date: 2005 / Resumo: Este trabalho teve como objetivo avaliar o efeito da escovação mecânica e termociclagem sobre dureza e rugosidade superficiais de três materiais reembasadores resilientes considerados definitivos, dois à base de silicone, um auto (Sofreliner MS) e outro termopolimerizável (Molloplast-B), além de um à base de resina acrílica autopolimerizável (Dentuflex). Para a confecção das amostras, foram utilizadas matrizes de silicone polimerizado por reação de condensação incluídas em muflas, obtendo um molde impresso no gesso posteriormente preenchido com os materiais resilientes. Foram confeccionadas 60 amostras, submetidas à leitura de rugosidade superficial num rugosímetro SURFCORDER SE 1700 (Kosaka Laboratory) e à leitura de dureza num durômetro Shore A (GS ¿ 709 Teclock, Osaka, Japão). Em seguida as amostras foram separadas em dois grupos, onde metade foi submetida ao ensaio de termociclagem numa máquina MSCT ¿ 3 PLUS regulada em 2.000 ciclos com banhos alternados de 60 segundos a 5±1oC e 55±1oC e a outra metade ao ensaio de escovação mecânica numa máquina MSEt, seguida de termociclagem. O ensaio de escovação foi executado sob carga estática de 200 g, com movimentos lineares, totalizando 30.000 ciclos, onde uma solução de dentifrício contendo água era liberada a cada 1 minuto sobre as amostras. Após os ensaios, foram executadas novas leituras de dureza e rugosidade superficial. Os valores obtidos foram submetidos à análise de variância em parcelas subdivididas no tempo, seguida do teste de Tukey em nível de 5% de significância. O material Dentuflex apresentou os maiores valores médios de rugosidade e dureza iniciais, seguidos do Molloplast-B e Sofreliner MS. Após termociclagem, os materiais Dentuflex e Sofreliner MS apresentaram aumento estatisticamente significante da dureza. Após escovação, o material Dentulfex apresentou diminuição nos valores de rugosidade e o Sofreliner MS aumento, ambos estatisticamente significantes. Após a escovação seguida de termociclagem, todos os materiais apresentaram valores de rugosidade estatisticamente semelhantes entre si, provavelmente devido ao polimento do material Dentuflex, abrasão do Sofreliner MS e preservação das características do Molloplast-B / Abstract: The aim of this study was to evaluate the effect of mechanical brushing and thermocycling on hardness and roughness of three resilient definitive lining materials: 1) auto (Sofreliner MS), 2) heat-polymerized (Molloplast-B) silicone bases; and 3) auto-polymerized plasticized acrylic resin (Dentuflex). To prepare the samples, silicone rubber matrixes were made and placed in a flask to obtain a cast pressed mold, and then filled with resilient lining materials, handled according to the manufacturer¿s directions. All samples were submitted to surface roughness readings in a roughness readings machine (SURFCORDER SE 1700 ¿ Kosaka Laboratory) and hardness readings in a Shore A durometer (GS ¿ 709 Teclock, Osaka, Japan). After the readings, the samples were assigned into 6 groups of 10 each, half of which were submitted to thermocycling treatment in a thermal cycler machine (MSCT ¿ 3 PLUS) for 2.000 cycles at temperatures ranging from 5±1oC to 55±1oC and a 60-second dwell time. The other half was submitted to a mechanical brushing simulation in an MSEt brushing machine followed by thermocycling. The samples were submitted to 30.000 strokes with linear brushing movements, under a 200 g static load pressure. Toothpaste solution was injected every one-minute break. Then new readings of hardness and roughness were done, and the values were submitted to variance analysis test followed by Tukey test, with 5% of significance. Dentuflex showed the highest initial values for both roughness and hardness, followed by Molloplast-B and Sofreliner MS. After thermocycling, Dentuflex and Sofreliner-MS showed a statistically significant increase in hardness values. After mechanical brushing, Dentuflex showed a decrease and Sofreliner MS an increase in roughness values. After mechanical brushing followed by thermocycling, all materials showed similar roughness values (statistically significant), probably due to the Dentuflex polished surface, the Sofreliner MS abrasion and the remained features of the Molloplast-B / Mestrado / Protese Dental / Mestre em Clínica Odontológica
39

Efeito da escovação mecanica e de agentes quimicos de limpeza de proteses sobre as caracteristicas superficiais de materiais reembasadores resilientes

Oliveira, Luciana Valadares 16 February 2005 (has links)
Orientador: Marcelo Ferraz Mesquita / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-04T03:56:46Z (GMT). No. of bitstreams: 1 Oliveira_LucianaValadares_M.pdf: 2328929 bytes, checksum: d3dcd162bfa4e1648664f19245daaffd (MD5) Previous issue date: 2005 / Resumo: O objetivo deste trabalho foi avaliar o efeito da escovação mecânica e de agentes de limpeza sobre as características superficiais de materiais reembasadores resilientes. Foram utilizados os materiais Luci Sof (Dentsply), Molloplast-B (Dentax) e Sofreliner (Tokuyama), os agentes de limpeza Hipoclorito de Sódio a 0,5% (Medicinallis-Fármacia de Manipulação-SP-BR) e Efferdent (Warner-Lamber Co-EUA), a escova dental extra macia Johnson & Johnson Reach Professional (Johnson & Johnson Industrial LTDA.) e dentifrício Sorriso Dentes Brancos (Kolynos do Brasil). Foram confeccionadas 30 amostras de cada material, a partir da moldagem do dispositivo porta matriz da máquina de ensaio de escovação mecânica, com 25mm de comprimento X 14mm de largura X 3mm de espessura. Dez amostras de cada material foram submetidas à escovação mecânica e 20 imersas em agente de limpeza. A escovação mecânica foi realizada na máquina MSEt (Máquina de Simulação de Escovação), com velocidade de 5 movimentos por segundo (20.000 ciclos). Foram utilizados 2 agentes de limpeza: 1) Hipoclorito de Sódio a 0,5% a 37 + 1ºC, durante 20 minutos; 2) Efferdent, a 37 + 1ºC, durante 15 minutos. Após as imersões, as amostras foram lavadas e imersas em água destilada, a 37 ± 1ºC, pelo período restante das 24 h. Esse processo foi repetido 8 vezes por dia, durante 90 dias (720 ciclos). A rugosidade superficial, dureza Shore A e observação em microscópio eletrônico de varredura foram avaliadas antes e após os métodos de higienização. A rugosidade foi avaliada em rugosímetro Surfcorder SE 1700 (Kosaka ¿ Laboratory Ltda.); o ensaio de dureza Shore A em durômetro modelo GS-709 (Teclock-Japão), com aplicação de carga de 10N durante 1 segundo; a microscopia eletrônica de varredura em microscópio modelo JSM 5600 PV (JEOL-Japão), onde foi observada a morfologia superficial de amostras representativas de cada tratamento. Os resultados obtidos foram submetidos aos Testes de Wilcoxon-Mann-Whitney e de Kruskal-Wallis (5%). A escovação aumentou significantemente os valores de rugosidade dos materiais. Luci Sof (Ra=0,74m), Molloplast-B (Ra=1,28m) e Sofreliner (Ra=3,18m) apresentaram diferença estatisticamente significante entre si. O tratamento em Efferdent promoveu diminuição significante dos valores de rugosidade de Luci Sof e Sofreliner. Após o tratamento, os materiais não apresentaram diferença estatisticamente significante entre si (Luci Sof Ra=0,32m; Molloplast-B Ra=0,32m; Sofreliner Ra=0,36m). A imersão em Hipoclorito promoveu diminuição significante os valores de rugosidade dos materiais. Luci Sof (Ra=0,29m) e Molloplast-B (Ra=0,27m) e Molloplast-B e Sofreliner (Ra=0,17m) não apresentaram diferença estatisticamente significante entre si. A escovação diminuiu os valores de dureza significantemente de Molloplast-B (35,10), mas não alterou esses valores de Luci Sof (43,80) e Sofreliner (27,10). Após a escovação, os materiais apresentaram diferença estatisticamente significante entre si. A imersão em Efferdent diminui significantemente os valores de dureza dos materiais. Após o tratamento, Molloplast-B (25,70) e Sofreliner (25,75) não apresentaram diferença estatisticamente significante entre si, mas diferiram de Luci Sof (36,65). A imersão em Hipoclorito diminui significantemente os valores de dureza de Molloplast-B e Sofreliner, e não alterou para Luci Sof. Após o tratamento, Molloplast-B (28,85) e Sofreliner (26,00) não apresentaram diferença estatisticamente significante entre si, mas diferiram de Luci Sof (43,80). A escovação mecânica foi o tratamento que promoveu os maiores valores de rugosidade superficial para todos os materiais avaliados. Após a escovação, todos apresentaram valores estatisticamente diferentes entre si, na ordem crescente: Luci Sof, Molloplast-B e Sofreliner. Os tratamentos de imersão promoveram a diminuição dos valores de rugosidade superficial apresentados pelos materiais Luci Sof e Molloplast-B, e elevação para o material Sofreliner quando imerso em Efferdent. A escovação diminuiu o valor mediano de dureza do material Molloplast-B. Após a escovação, todos apresentaram valores estatisticamente diferentes entre si, na seguinte crescente: Sofreliner, Molloplast-B e Luci Sof. A imersão em Efferdent promoveu diminuição significativa dos valores de dureza para todos os materiais. A imersão em Hipoclorito de Sódio promoveu diminuição significativa dos valores de dureza dos materiais Sofreliner e Molloplast-B / Abstract: The aim of this study was to evaluate the influence of mechanical brushing and denture cleansers on the surface properties of soft lining materials. Three soft liners, Luci Sof (Dentsply), Molloplast-B (Dentax), and Sofreliner (Tokuyama), two denture cleansers Efferdent (Warner-Lamber Co- EUA), and 0,5% alkaline hypochlorite preparation, the Reach Professional toothbrush (Johnson & Johnson) and the dentifrice Sorriso Dentes Brancos (Kolynos do Brasil) were used. Thirty specimens of each soft liner material were prepared by molding the specimen container appliance of the brushing machine, measuring 25mm long, 15mm wide and 3mm thick. Ten specimens of each material were submitted to the mechanical brushing assay, and 20 specimens of each material immersed into the solution of each denture cleanser. The mechanical brushing assay was conducted on the MSEt plus machine, at a rate of 5.0 strokes per second (20.000 cycles). Two denture cleansing approaches were used: 1) specimens immersed in 0.5% alkaline hypochlorite preparation at 37 ± 1 ºC for 20 minutes; 2) specimens immersed in Efferdent at 37 ± 1 ºC for 15 minutes. The specimens were then washed thoroughly with tap water, and immersed into distilled water, for the remainder of the 24 h period, at 37 ± 1 ºC. This procedure was repeated 8 times a day, during 90 days (720 cycles). The specimens were evaluated before and after the cleansing procedures. The surface roughness was evaluated in a profilometer SE 1700 (Kosaka ¿ Laboratory), and the Shore A hardness in a microdurometer GS-709 (Teclock, Japan) with a penetrating load of 10N for 1 second. The observation of superficial morphology from representative specimens of each method of cleanser were observed using a scanning electron microscope JSM 5600 PV model (JEOL-Japan). All numeric data were subjected to Wilcoxon-Mann-Whitney and Kruskal-Wallis tests at the 5% level. The mechanical brushing assay increased significantly the roughness mean values for all materials. The mean values for Luci Sof (Ra=0.74m), Molloplast-B (Ra=1.28m) and Sofreliner (Ra=3.18m) were statistically different after the brushing assay. The Efferdent treatment decreased the roughness mean values of Luci Sof and Sofreliner significantly, but not for Molloplast-B. After the treatment, no differences in the mean values were observed among the materials (Luci Sof Ra=0.32m; Molloplast-B Ra=0.32m; Sofreliner Ra=0.36m). The Hypochlorite treatment decreased the roughness mean values of all materials significantly. After the treatment, neither Luci Sof (Ra=0.29m) and Molloplast-B (Ra=0.27m) nor Molloplast-B and Sofreliner (Ra=0.17m) showed statistically significant differences. The brushig assay decreased the hardness mean values significantly only for Molloplast-B. After the assay, no statistically significant differences were observed for Luci Sof (43.80), Molloplast-B (35.10) and Sofreliner (27.10). The Efferdent treatment decreased the hardness mean values significantly for all materials. After the treatment, mean values of Molloplast-B (25.70) and Sofreliner (25.75) were not statisticaly different, but they differed from that of Luci Sof (36.65). The Hypochlorite treatment decreased the hardness mean values of Molloplast-B and Sofreliner. After the treatment, mean values of Molloplast-B (28.85) and Sofreliner (26.00) were not statisticaly different, but they differed from that of Luci Sof (43.80). The mechanical brushing assay increased the roughness mean values for all materials significantly, from smoothest to roughest in the following order: Luci Sof, Molloplast-B, and Sofreliner. The denture cleansers decreased the roughness mean values of Luci Sof and Molloplast-B, and increased this values for Sofreliner in Efferdent. The mechanical brushing decreased the hardness mean value of Molloplast-B, and after this treatment, all materials showed statistical significantly differences, from smoothest to hardest in the following order: Sofreliner, Molloplast-B, and Luci Sof. The Efferdent treatment decreased the hardness mean values for all materials significantly. The Hypochlorite treatment decreased the hardness mean values for Sofreliner and Molloplast-B significantly / Mestrado / Protese Dental / Mestre em Clínica Odontológica
40

Estudo da adaptação e porosidade de bases de proteses confeccionadas com resina acrilica dental submetidas a dois ciclos de polimerização

Rodrigues-Garcia, Renata Cunha Matheus, 1964- 28 September 1995 (has links)
Orientador: Altair Antoninha Del Bel Cury / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-20T17:02:17Z (GMT). No. of bitstreams: 1 Rodrigues-Garcia_RenataCunhaMatheus_D.pdf: 2889884 bytes, checksum: a95426c1f4c9cf7fb15fbe65551ab547 (MD5) Previous issue date: 1995 / Resumo: Este estudo verificou a adaptação e porosidade de bases de prótese submetidas a um duplo ciclo de polimerização. Foram confeccionados 36 modelos em gesso pedra a partir de moldagem de um modelo-mestre metálico. Esses modelos foram divididos em 03 grupos de 12 elementos cada. Bases de resina acrílica convencional foram confeccionadas sobre os modelos dos grupos 1 (G 1) e 2 (G2), polimerizados em banho de água durante 9 horas a 730 C; e bases de resina específica para microondas foram construídas sobre os modelos do grupo 3 (G3) e curadas em fonlO de microondas a 500W durante 3 mino A adaptação foi verificada através do peso de um material de impressão interposto entre a base da resina e o modelo mestre sob carga de 2 Kg. A seguir todas as bases foram reembasadas pelo método de adição, sendo que aquelas dos grupos 1 e 3 foram reembasadas com o mesmo material e técnica de polimerização. As bases do grupo 2 foram preenchidas com a mesma resina, porém curadas em fonlO de microondas a 500W durante 3 mino A adaptação foi reavaliada da maneira descrita acima. A porosidade foi verificada através de imersão das amostras polidas em tinta preta, e os poros contados em lupa esteroscópica com aumento de 63x. As médias e desvios-padrão obtidos para a adaptação antes e após o reembasamento foram: G 1: 0,632 + 0,024 - 0,659 + 0,026; G2: 0,632 :t 0,033 - 0,677 + 0,031; G3: 0,580 + 0,019 - 0,798 + 0,049, sendo que houve diferença sigllificante apenas para o G3. As médias e desvio-padrão para a porosidade antes e após o reembasamento for'!ffi respectivamente: G 1 = 8,33 + 0,69 - 9,25 + 0,85; G2 = 8,17 + 0,98 - 10,08 + 1,63; G3 = 5,42 + 0,78 - 6,58 + t02, sendo que não houve diferenças significantes entre os grupos estudados após o reembasamento. Conclui-se que a resina convencional, quando polimerizada no primeiro ciclo pelo método convencional e no segundo ciclo através de energia de microondas, apresentou adaptação semelhante ao método convencional de reembasamento. Em relação à porosidade foi verificado que, tanto após o primeiro como o segundo ciclo de cura, a resina convencional apresentou maior número de poros / Abstract: In this study was verified the accuracy and porosity of denture submitted for double cycles of polymerization. Thirty six mas ter cast were made in dental stone from the impression of metal die. These master cast were divided by three groups of 12 elements each. Denture bases of conventional acrylic resin were made on the casts of the groups I e II (GI and GIl), polymerized in water bath duril1g 9 hours at 730C, and specific resin for denture bases for microwave polymerization were made on the casts of group III (GllI) and cured in microwave oven at 500W during 3 minutes. The accuracy was verified by the weight of a impression material was put between the denture base and cast die under load of 2 Kg. Afterwards, all the denture bases were relining by addition method, and those of the group 1 and III were relined with the same material and polymerization tech.l11c. The denture bases of the group II were filled with the same resin, however cured in microwave oven with 500W during 3 mil1utes. The accuracy was revaluable by the same way as described above. The porosity, was verified by the immersion of the polish specimens in a solution of pennanent black i.nk and the pores were counted through a stereo light microscope with under magnification of 6,3 x. The average and standard deviation gotten for an accuracy before and after the relinil1g were respectively: G 1: 0,632 + 0,024 - 0,659 + 0,026; G2: 0,632 + 0,033 - 0,677 + 0,031; G3: 0,580 + 0,018 - 0,798 + 0,049. There was a significant difference only for the group TIl. The average and standard deviatio.l1 for the porosity before and after the relining were respectively: Gl = 8,33 + 0,63 - 9,25 + 0~85; G2 = 8,17 + 0,98 + 10,08 + 1,63; G3 = 5,42 + 0,78 - 6,58 + 1,02. The concluslon is that the conventional resin when polymerizated in the fust cycle by conventional method and in the second cycle by microwaves energy showed similar accuracy to conventional relining. ln relatiori to the porosity was verified that as after the fust and second cycle of polymerization, the conventional resin showed the highest number of pores / Doutorado / Protese Dental / Doutor em Odontologia

Page generated in 0.1277 seconds