• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 710
  • 37
  • 37
  • 37
  • 37
  • 28
  • 9
  • 8
  • 4
  • 4
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 728
  • 728
  • 357
  • 269
  • 232
  • 185
  • 141
  • 141
  • 123
  • 118
  • 107
  • 105
  • 89
  • 80
  • 77
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
211

Efeito da complementação térmica de polimerização sobre a resistência flexural e dureza de resinas acrílicas para reembasamento

Seó, Rosangela Seiko [UNESP] 25 February 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:56Z (GMT). No. of bitstreams: 0 Previous issue date: 2003-02-25Bitstream added on 2014-06-13T19:58:18Z : No. of bitstreams: 1 seo_rs_me_arafo.pdf: 703350 bytes, checksum: 5c30291cb31b160b0c3ae925308ad49c (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O procedimento de reembasamento da prótese é normalmente utilizado para restabelecer a adaptação entre a prótese e o tecido bucal. As resinas autopolimerizáveis são um dos materiais indicados para o reembasamento. No entanto, tem sido demonstrado que, após a polimerização das resinas autopolimerizáveis, nem todo o monômero é convertido em polímero e esse monômero residual pode afetar as propriedades mecânicas desses materiais. Estudos têm sugerido que o conteúdo de monômero residual pode ser reduzido pela irradiação em microondas ou tratamento em banho de água. Esse estudo avaliou o efeito dos tratamentos térmicos sobre a resistência à flexão e dureza Vickers de quatro resinas autopolimerizáveis para reembasamento (Duraliner II - D, Kooliner-K, Tokuso Rebase Fast - TR e Ufi Gel Hard - UGH) e uma resina termopolimerizável (Lucitone 550 - L). Para cada material, trinta corpos-de-prova foram confeccionados e igualmente divididos em três grupos. No grupo controle, os corpos-de-prova foram submetidos ao teste de resistência à flexão imediatamente após sua polimerização. Previamente ao teste, os grupos 2 e 3 foram submetidos ao tratamentos complementares em banho de água e irradiação por microondas, respectivamente. Os corpos-de-prova do material para base de prótese foram armazenados em água por 48 horas a 37o l 1oC previamente ao teste. As medidas de força foram realizadas em máquina de ensaio universal MTS 810 com uma velocidade de 5 mm/min, utilizando o teste em três pontos a uma distância de 50 mm entre os apoios. Em seguida, um dos fragmentos do corpo-de-prova foi submetido ao teste de dureza Vickers. Os valores de dureza foram determinados utilizando-se uma carga de 25 gf (resinas K, TR, L e UGH) e 10 gf para a resina D, após 30 segundos de contato. Doze mensurações de dureza foram realizadas em cada corpo-de-prova e... / To maintain the prosthesis-tissue relationship, denture base reline procedure is commonly required. Autopolymerizing resins are one of the materials indicated for relining. It has been shown that, after polymerization, not all the monomer is converted to polymer in autopolymerizing resins and this residual monomer could detrimentally affect the mechanical properties of the materials. It has been suggested that the residual monomer could be decreased by microwave irradiation or water bath heat-treatments. This study investigated the effect of heat treatments on the flexural strength and Vickers hardness of four autopolymerizing reline resins (Duraliner II - D, Kooliner-K, Tokuso Rebase Fast-TR and Ufi Gel Hard-UGH) and one heat-polymerized resin (Lucitone 550-L). For each material, 30 specimens were made and equally divided into three groups. In control group, the specimens were submitted to the flexural strength test immediately after polymerization. Before testing, groups 2 and 3 were submitted to water bath and microwave post-cure treatments, respectively. The denture base material specimens were stored in water for 48 h at 37o l 1oC before they were bend-tested. Force measurements were made with a testing machine MTS 810 at a crosshead speed of 5 mm/min using a three-point bending fixture with a span of 50 mm. Thereafter, one fragment of specimen was submitted to Vickers microhardness test. The values were determined by using a 25 gf load (resins K, TR, UGH and L) and 10 gf for resin D, after 30 s contact. Twelve hardness measurements were taken on each specimen and the average was then calculated. Kruskal-Wallis non-parametric test was used for determination of statistical significance (p<0.01). The results demonstrated that: compared to the control groups, the flexural strength of TR and...(Complete abstract, click electronic access below)
212

Efetividade da irradiação por microondas na desinfecção de próteses totais

Silva, Mariana Montenegro [UNESP] 17 February 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:56Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-02-17Bitstream added on 2014-06-13T18:58:05Z : No. of bitstreams: 1 silva_mm_me_arafo.pdf: 485003 bytes, checksum: a3299f64dc8ce209e1a2c0ea6740be6d (MD5) / Este estudo teve por objetivo avaliar a efetividade da irradiação por microondas na esterilização de próteses totais. Para isso, oitenta próteses totais padronizadas foram confeccionadas e submetidas à esterilização com óxido de etileno. As próteses foram então individualmente inoculadas (107 ufc/mL) com meio de cultura de Tryptic Soy Broth (TSB) contendo um dos seguintes microrganismos: C.albicans, S. aureus, B. subtilis e P. aeruginosa. Após 48 horas de incubação a 37oC, 40 amostras foram imersas em 200 mL de água e irradiadas a 650 W por 6 minutos. Quarenta amostras não irradiadas foram utilizadas como controle. A seguir, 25 uL da suspensão resultante das diluições seriadas de 10-1 a 10-6, foram semeados em placas de Petri contendo os meios de cultura seletivos para cada microrganismo. Todas as placas foram incubadas a 37oC por 48 horas. Após a incubação, as colônias foram quantificadas em ufc/mL. Para verificação da efetividade exposição às microondas em longo prazo as amostras irradiadas foram imersas em meio de cultura e incubadas a 37oC por 7 dias. A esterilização foi obtida, após 48 horas, para as próteses contaminadas com C.albicans, S. aureus e B. subtilis. Um pequeno número de colônias foi observado em 2 placas de Petri para o microrganismo P. aeruginosa. Após 7 dias de incubação a 37oC houve crescimento microbiológico em 3 culturas de TSB, sendo 2 para P. aeruginosa e um para B. subtilis. Todas as próteses totais do grupo controle apresentaram crescimento microbiano nas placas de Petri, após 48 horas de incubação a 37oC. A irradiação por microondas por 6 minutos a 650 W provou ser um método rápido e efetivo para desinfecção das próteses totais contaminadas com P. aeruginosa e B. subtilis além, de promover a esterilização das inoculadas com C. albicans e S. aureus. / The aim of this study was to evaluate the effectiveness of microwave irradiation on the sterilization of complete dentures contaminated with individual suspension of 3 bacterias (P. aeruginosa, S. aureus and B. subtilis) and one fungus (C. albicans). Eighty simulated maxillary complete dentures were fabricated in a standardized procedure and subjected to ethylene oxide sterilization. The dentures were individually inoculated (107 cfu/mL) with Tryptic Soy Broth (TSB) media containing one of the tested microorganisms. After incubation at 37°C for 48 hours, forty dentures were immersed in 200 mL of distilled water and submitted to microwave irradiation at 650 W for 6 minutes. Forty non – irradiated dentures were used as positive controls. Using 0.9% sodium chlorine solution as diluent, tenfold serial dilutions 10-1 – 10-6 were plated onto 4 selective media appropriate for each organism: Manitol Salt Agar for S. aureus, Miller Hinton for P. aeruginosa, Sabourand Agar containing 5 μg/mL gentamicin for C.albicans, and Tryptic Soy Agar for B. subtilis. All plates were incubated at 37°C for 48 hours and colonies counts of each plate were quantified (cfu/mL). To verify the long - term effectiveness ofmicrowave sterilization, the TSB beakers with the microwave specimens were incubated at 37°C for 7 days. Data were statistically analyzed by Kruskal – Wallis’s test (α=0.05). Irradiated dentures showed consistent sterilization of S. aureus, B. subtilis and C. albicans after 48 hours. Compared to P. aeruginosa control, a very low number of colonies were detected only in two plates. Turbidity was observed in three broth beakers, two from P. aeruginosa and one from B. subtilis, after 7 days incubation at 37°C. All control dentures showed microbial...(Complete abstract, click electronic access below)
213

Influência de agentes adesivos, irradiação por microondas e ciclagem termomecânica na resistência de união entre uma resina acrílica termoativada e um reembasador rígido

Cavalcanti, Sâmia Carolina Mota [UNESP] 04 July 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-07-04Bitstream added on 2014-06-13T19:58:21Z : No. of bitstreams: 1 cavalcanti_scm_me_sjc.pdf: 1140033 bytes, checksum: ed396d8f55380698b309d4a7c2f4f6cb (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Este trabalho tem como objetivo analisar a resistência de união entre uma resina acrílica ativada térmicamente (Vipiwave) e um reembasador rígido (Tokuyama rebase fast II) considerando-se fatores que possam influenciar nesta união, tais como: agentes adesivos, irradiação por micro-ondas e ciclagem termomecânica. Para a execução da pesquisa estabeleceram-se 16 grupos (n=10), para qual foram confeccionados corpos de prova em formato cilíndrico(13mmx23mm) em resina acrílica termoativada em forno de micro-ondas. Após a polimerização, estes receberam acabamento com lixa d’agua 400 e tiveram suas superfícies tratadas com Tokuyama Rebase II adhesive, adesivo Palabond ou o monômero da resina Vipiwave, e reembasados. Uma parte dos corpos de prova foi tratado em micro-ondas, sendo imersos em 200ml de água, e submetidos a um ciclo de 3 min a 650W. Outros grupos foram levadosa ciclagem termomecânica, onde o estresse mecânico foi de 10.000 ciclos a 3,8 Hz. Todos os corpos de prova foram submetidos ao teste de cisalhamento, com velocidade de 1mm/min e carga de 100Kgf em máquina de ensaios universal. Os corpos de prova passaram em avaliação por perfilometria. Após obtenção dos resultados, estes foram submetidos a análise estatística por Anova e Tukey (5%) para comparação entre os grupos. Verificou-se que tanto a irradiação em micro-ondas quanto a ciclagem termomecânica melhoraram significativamente a união nos grupos tratados com Palabond. Os grupos Tokuso e controle apresentaram melhor resistência adesiva após a ciclagem embora o grupo controle apresentasse os piores valores de resistência em todas as situações. Já os resultados de perfilometria mostraram que o adesivo Palabond criou uma superfície mais rugosa (Ra=185,4 m) quando comparado ao grupo Tokuso (Ra= 121,9 m). Concluiu-se desta... / The aim of this study was to analyze the shear bond strength between a heat-activated acrylic resin (Vipiwave) and a soft liner (Tokuyama Rebase Fast II) considering factors that can influence bonding, such as adhesive agents, microwave irradiation and thermomechanical cycling. Sixteen groups (n=10) were stablished, and specimens of heat-activated acrylic resin were fabricated in a cylindrical shape (13mmx23mm) in microwave oven. After curing, they were finished with #400 sandpaper, the bonded surfaces were treated with Tokuyama Rebase II adhesive, Palabond or Vipiwave monomer, and were relined with Tokuyama Rebase Fast II. Half of specimens were microwave-cured (3 minutes at 650W). Remainder were heat-cured in water. Half of specimens were thermomechanical cycled (10,000 cycles at 3.8 Hz). Specimens were submitted shear bond strength test with crosshead speed of 1mm/min in a universal testing machine. Fractured specimens were evaluated in profilometry. Data (MPa) were submitted to 3-way ANOVA and Tukey test, both with =0.05 for comparison between groups. Microwave-cured and thermamechanical cycled Palabond treated groups showed higher bond strength. Untreated groups showed the lowest shear bond strengths and the groups treated with Tokuyama adhesive the highest bond strength values. Profilometry showed that Palabond created a rougher surface (Ra = 185.4 m) compared to Tokuso (Ra = 121.9 m). It was concluded that the surface treatment prior to relining, especially with Palabond produces satisfactory results, and microwave irradiation and thermomechanical cycling showed improvement of bond strength
214

Distribuição das tensões geradas ao redor de implantes osseointegrados de diferentes conexões cone morse : análise fotoelástica e pelo método dos elementos finitos /

Anami, Lilian Costa. January 2011 (has links)
Orientador: Fernando Eidi Takahashi / Banca: Alexandre Luiz Souto Borges / Banca: Cristiane Aparecida de Assis Claro / Resumo: O objetivo deste trabalho foi avaliar a localização e distribuição das tensões geradas ao redor de implantes com pilares protéticos de diferentes conexões cone Morse através da análise fotoelástica (AFE) e do método dos elementos finitos (MEF). Para o MEF, implante e pilares protéticos de diferentes conexões cone Morse (hexagonado e sólido) foram digitalizados pela técnica da microtomografia computadorizada e, com auxílio de softwares computacionais foi realizada a modelagem da malha tridimensional e o carregamento dos objetos. Foi realizada a caracterização das propriedades mecânicas da resina fotoelástica. Foram simulados blocos com propriedades mecânicas de osso cortical e trabecular e de resina fotoelástica. A AFE foi realizada a partir de blocos de resina fotoelástica onde foram incluídos os implantes aparafusados aos diferentes pilares protéticos. Estes blocos foram confeccionados a partir de um bloco prototipado do modelo utilizado no MEF. Os corpos-deprova foram imersos em um recipiente com óleo mineral e o conjunto foi observado no polariscópio circular com dispositivo de aplicação de cargas acoplado e recebendo a mesma carga, em sentido e posição iguais. Foi feita análise descritiva para as imagens obtidas em ambas as metodologias onde observou-se que: as imagens obtidas no MEF apresentaram distribuição de tensões bastante similar entre os dois modelos com diferentes pilares protéticos. Foram observadas diferenças entre a distribuição das tensões em blocos ósseo e de resina; As imagens obtidas na AFE se assemelharam às obtidas em MEF com bloco de resina. As imagens da AFE também foram analisadas quantitativamente, por comparação a valores atribuídos às franjas. A concordância interobservadores foi conferida pelo teste de Dahlberg. Concluiu-se que o Pilar Sólido transfere cargas mais homogeneamente para o osso adjacente ao implante... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The goal of this study was to evaluate the location and distribution of stresses generated around implants with different Morse taper connections abutments by photoelastic (PA) and finite element analysis (FEA). For FEA, implant and abutments with different Morse taper connections (hexagonal and solid) were scanned by computerized microtomography technique. The tridimensional mesh was modeled and the objects were loaded with the help of computer software. Photoelastic resin was characterized by mechanical properties. Trabecular and cortical bone and photoelastic resin blocks were simulated with their respective mechanical properties. The PA was performed with photoelastic resin blocks where implants were included and the different abutments were bolted. These blocks were made from a prototyped block of model used in FEA. Specimens were immersed in a mineral oil container and it was observed in the circular polariscope with the application device attached, where loads were received on same charge, on equal direction and position. Images obtained in both methodologies were descriptively analyzed where it was that: FEA images showed very similar stress distribution between two models with different abutments. Differences were observed between stress distribution in bone and resin blocks; PA images resembled those obtained on resin block FEA. PA images were also quantitatively analyzed by comparing the values assigned to fringes. Inter-observer agreement was given by Dahlberg test. It was concluded that solid abutment distributes loads more evenly to bone adjacent to implant compared with hexagonal abutment, for both analysis methods employed. Among the methodologies employed, it was observed that the PA has generated very similar results to those obtained in FEA with resin block, but different to those obtained in FEA when the clinical condition of the bone block was simulated / Mestre
215

Avaliação da distribuição das tensões em prótese do tipo "All on Four" : estudo pelo método dos elementos finitos tridimensionais /

Amoroso, Andressa Paschoal. January 2013 (has links)
Orientador: Humberto Gennari Filho / Co-orientador: José Vitor Quinelli Mazaro / Banca: Fellippo Ramos Verri / Banca: Ricardo Shibayama / Resumo: Considerando o aumento crescente e contínuo da demanda por tratamento protético reabilitador sobre implantes, aliado ao sucesso comprovado dos implantes osseointegrados, fazem com que a procura de meios possam fortalecer ainda mais este tipo de tratamento, seja abundante, principalmente no que diz respeito à distribuição das forças. Proposta: o objetivo desse trabalho foi analisar a distribuição das tensões geradas em diferentes configurações da prótese tipo protocolo, através do método dos elementos finitos tridimensionais. Materiais e método: para a realização deste estudo foram confeccionados 2 modelos mandibulares com auxílio dos programas de modelagem gráfica SolidWorks 2010 (SolidWorks Corp, Massachusetts, EUA) e Rhinoceros® 3D 4.0 (NURBS Modeling for Windows, EUA). Cada modelo representou uma mandíbula com prótese protocolo sobre implantes de hexágono externo 4,0 x 13,0mm (Master, Conexão Sistemas de Prótese Ltda., São Paulo, Brasil) localizados na região interforaminal, variando a inclinação. Modelo 1: prótese com 4 implantes dispostos perpendicularmente à crista do rebordo e modelo 2: prótese do tipo All on four (implantes distais inclinados em 30º). A representação da prótese foi em resina acrílica e a infra estrutura metálica em NiCr. Os desenhos tridimensionais foram exportados ao programa de elementos finitos FEMAP 11.0 para geração da malha. A carga axial aplicada foi de 300N, bilateral sendo 75N em cada dente, e a oblíqua 150N, unilateral sendo 75N em cada dente, em 1º pré-molares e 1º molares. Resultado: após a análise no programa NEiNastran® 9.2 (Noran Engineering, Inc., EUA), os resultados foram... / Abstract: The increasing and continuous demand for implants prosthetic rehabilitation along with the proven success of dental implants make that search for means which can further strengthen this type of treatment is abundant, especially regarding the distribution of forces. Purpose: The aim of this study was to analyze the stress distribution generated in different configurations of the full-arch implant-supported prostheses, through the three-dimensional finite element method. Material and method: For this study two mandibular models were made using the graphical modeling program SolidWorks 2010 (SolidWorks Corp., Massachusetts, USA) and Rhinoceros® 3D 4.0 (NURBS Modeling for Windows, EUA). Each model represented a jaw with a full-arch implant-supported prosthesis using external hexagon implants with 4.0 x 13.0 mm (Master Connection Implant Systems Ltda., São Paulo, Brazil) located in the interforaminal region, varying the inclination. Model 1: prosthesis with 4 implants arranged perpendicularly to the ridge crest and model 2: All-on-four prosthesis (distal implants tilted at 30 °). The representation of the prosthesis was with acrylic resin and the metallic infrastructure with NiCr. The three-dimensional images were exported to finite element programs FEMAP 11.0 for mesh generation. The axial load applied was 300N, being 75N bilateral in each tooth, and oblique of 150N, being 75N unilateral in each tooth, in 1st premolars and 1st molars. Results: After analysis at the program NEiNastran® 9.2 (Noran Engineering, Inc., EUA), the results were visualized through individualized maps of von Mises stress and main maximum stress on each model. It can be observed in the model with tilted implants, that for both loads the stress concentrations were higher. Conclusion: It was concluded that the All on four prostheses presented highest stress concentrations, especially in the region of the distal implant. / Mestre
216

Avaliação da eficácia de um gel de vedação no selamento da interface pilar/implante e na manutenção da pré-carga dos parafusos de retenção /

Seloto, Camila Berbel. January 2017 (has links)
Orientador: Wirley Gonçalves Assunção / Banca: Paulo Henrique dos Santos / Banca: Juliana Aparecida Delben / Resumo: Esse estudo avaliou a eficácia de um material de vedação na manutenção da pré-carga em parafusos de retenção bem como o desajuste pilar/implante e microinfiltração após ciclagem mecânica. Foram formados seis grupos (n=12) sendo, um grupo teste (T) e um grupo controle (C) para cada tipo de conexão pilar/implante (conexão hexagonal externa (HE) e pilares UCLA; conexão cone Morse (CM) e pilares UCLA; e conexão CM e pilares flexcone (FC)). Nos grupos testes (HET, CMT e FCT) foi aplicado um agente de vedação no parafuso de retenção, enquanto os grupos controle (HEC, CMC e FCC) foram mantidos da forma convencional. Todos os implantes foram embutidos em poliuretano e foram introduzido 0,7μl de Azul de Toluidina (AT) na porção mais profunda de cada um deles. Em seguida, os pilares foram posicionados sobre os implantes e parafusados com o torque recomendado pelo fabricante com auxílio de chave especifica e um torquímetro digital. Formados os corpos-de-prova, estes foram submetidos à ciclagem mecânica (1x106 ciclos), com frequência de 2Hz e carregamento oblíquo de 130N. As avaliações dos desajustes foram realizadas em um estereomicroscópio antes e após a ciclagem mecânica. Para verificar a capacidade de vedação do agente após a ciclagem mecânica foi desenvolvida uma curva padrão, na qual determinou-se a diluição de azul de toluidina (AT). Em seguida, os dados foram analisados em espectrofotômetro para a formação da curva padrão. Na sequência, os corpos-de-prova foram colocadas individu... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the effectiveness of a sealing material in preload maintaining of retaining screws and the misfit on implant / abutment interface after mechanical cycling. It was formed six groups (n=12), being one test group (T) and other control group (C) for each type of abutment / implant connection (external hexagonal connection (EH) and UCLA abutments, Morse taper (MT) and UCLA abutments, and CM connection and flexcone (CF) abutments). In the test groups (EHT, MTT and CFT) a sealing agent was applied on the retention screw, whereas the control groups (EHC, MTC and CFC) were maintained in the conventional manner. All implants were embedded in polyurethane and into the deeper portion of each implant it was introduced 0.7 μl of Toluidine Blue (TB). After that, the abutments were screwed to the implants with the torque values recommended by the manufacturer with the aid of a specific wrench and a digital torque wrench. The specimens formed were submitted to mechanical cycling (1x106 cycles) with frequency of 2Hz and oblique loading of 130 N. The misfit evaluation were performed at a stereomicroscope before and after a mechanical cycling. In order to verify the gel sealing ability after the mechanical cycling a standard curve was performed to determine the blue toluidine (TB) dilution. Then the data obtained were analyzed in a spectrophotometer for a standard curve formation. Afterwards, the specimens were placed in vials containing 400μl of distilled water. The spectrophotometric analysis was performed at 8 different times (1, 3, 6, 24, 48, 72, 96 and 144 hours). Finally, measurements of final destorque values (post-cycling) were performed. The misfit data, destorque and dye release (sealing ability) were obtained and submitted to normality statistical tests and then analyzed by ANOVA and Tukey tests (α = 0.05). The ANOVA... / Mestre
217

Avaliação das microdeformações ao redor de implantes, na utilização de pilares protéticos retos e angulados 17° e 30°, sob a influência de aplicação de cargas /

Rodrigues, Vinícius Anéas. January 2017 (has links)
Orientador: Renato Sussumu Nishioka / Banca: Sergio Eduardo de Paiva Gonçalves / Banca: Alfredo Mikail Melo Mesquita / Banca: Lucilene Hernandes Ricardo / Banca: Luis Gustavo Oliveira de Vasconcellos / Resumo: O objetivo deste estudo in vitro foi analisar a distribuição das microdeformações geradas ao redor de implantes de hexágono externo, sob a influência da utilização de intermediários do tipo mini pilares cônicos retos e angulados 17° e 30°, sob cargas axiais e não axiais, por meio da análise de elementos finitos e extensometria. Os modelos tridimensionais foram criados simulando três blocos de poliuretano, os quais receberam três implantes cada, um grupo perpendicular e outros dois com fixações inclinadas em 17° e 30°. Para o estudo também foram modelados os intermediários do tipo mini pilar cônico reto e angulados e uma supraestrutura metálica padronizada para ambos os grupos, os materiais foram considerados homogêneos, isotrópicos e lineares. Após a confecção, as geometrias foram exportadas em malhas para o software de análises (ANSYS 15.0, ANSYS Inc., Houston, USA), um carregamento axial de 30 kgf foi aplicado e os valores de tensão e as microdeformações foram analisados. Para análise in vitro, foram confeccionados blocos idênticos aos desenhados anteriormente. Foram colados sete extensômetros na superfície dos blocos, quatro tangenciando cada um dos implantes e três na transversal dos implantes. Coifas plásticas foram adaptadas a um enceramento padronizado e depois fundidas. A supraestrutura metálica foi parafusada com torque de 10 N.cm. Para aplicação de cargas foi utilizado um dispositivo de aplicação de cargas (DAC) com uma carga de 30 kgf. durante 10 segundos. Os dados... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The objective of this in vitro study was to analyze microstrains distribuition generated around external hexagon implants, under the influence of intermediary prosthetic componentes as straight, 17° and 30° angled miniconical abutments, under axial and non-axial loads, by finite elements and strain-gauge analysis. The three-dimensional models were created simulating three polyurethane blocks, being installed three implants each, one perpendicular group and another two with inclined fixations at 17° and 30°. For the study were also created straight and angled miniconical abutments and a standardized metallic superstructure for both groups. The materials were considered symmetrical, isotropic and solid. After the preparation, the geometries were exported in mesh to the analysis software (ANSYS 15.0, ANSYS Inc., Houston, USA). An axial load of 30 kgf was applied and the values of main maximum stress and microstrains were analyzed. For in vitro analysis, blocks identical to those created previously were made, seven strain-gauges were placed on the surface of the block, four tangential to each of the implants and three transverse to the implants. Plastic copings were adapted to a wax pattern and then cast. The metallic superstructure was screwed with a torque of 10 N.cm. For load application, a load application device (DAC) with a load of 30 kgf was used, for 10 seconds. Data were submitted to ANOVA and Tukey tests (p <0.05). Statistical difference was observed for "Implant angulation" factors (P = 0.000) and "Load application point" factor (P = 0.000). The data obtained by the finite element analysis were presented as: qualitative results of stress that were analyzed following the color scheme of the scale and results of deformation values, presented in graphs, where it observed a higher concentration of tension in the inclined implants in 30° at the ... (Resumo completo, clicar acesso eletrônico abaixo) / Doutor
218

Fratura precoce da porcelana em restaurações com infra-estrutura de zircônia : influência de gradientes térmicos no desenvolvimento e magnitude de tensões residuais e transitórias /

Benetti, Paula. January 2012 (has links)
Orientador: Alvaro Della Bona / Coorientador: Tarcísio José Arruda Junior / Coorientador: John Robert Kelly / Banca: Alexandre Luiz Souto Borges / Banca : Rubens Nisie Tango / Banca : Liliana Gressler May / Banca : Mario Alexandre Coelho Sinhoreti / Resumo: Esse estudo avaliou o desenvolvimento de tensões dentro da porcelana de restaurações metalo-cerâmicas (MC) e de zircônia-porcelana (ZC) como resultado de diferentes taxas de resfriamento a partir de temperaturas acima da transição vítrea (Tg). Restaurações unitárias (coroas) foram fabricadas com 1 ou 2 mm de espessura de porcelana. Termopares foram posicionados nas superfícies de cimentação (T1) e oclusal (T4) e inseridos na interface (T2) e dentro da porcelana (T3). Para o resfriamento rápido, o forno foi aberto imediatamente após o tempo de sinterização e desligado. O resfriamento lento foi obtido pela abertura do forno quando a 50°C abaixo da Tg. Modelos axi-simétricos foram construídos para simulação de tensões térmicas tempo-dependentes usando análise de elementos finitos (AEF). Equações de temperatura em função do tempo obtidas por termopares foram inseridas no modelo como condições das margens. A mudança do coeficiente de expansão térmica, densidade, módulo de cisalhamento, capacidade térmica e da Tg de acordo com a taxa de resfriamento foi considerada para simulação do comportamento da porcelana em temperaturas acima da Tg (visco-elástico). O comportamento dos materiais de infra-estrutura e da porcelana abaixo da Tg foi considerado elástico. A taxa de resfriamento na faixa de temperatura próxima a Tg foi 20°C/min e 900°C/min para resfriamento lento e rápido. Durante o resfriamento lento, os diferentes termopares mostraram temperaturas similares em ambas as coroas. Gradientes de temperatura foram observados no resfriamento rápido da coroa ZC (T1-T4 = 100°C) e, em menor magnitude, para a MC (T1-T4 = 30°C). Os resultados de AEF mostraram diferenças de tensão... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the development of transient and residual stresses within the porcelain of veneered restorations (zirconia- and metal-based) as a result of different cooling rates from temperatures above the glass transition temperature (Tg). All-ceramic (porcelain on zirconia-based ceramic) and porcelain-fused-to-metal (PFM) molar crowns were fabricated with 1 mm or 2 mm porcelain thickness. Thermocouples were attached to intaglio (T1) and occlusal (T4) surfaces and embedded within the ceramics interface (T2) and inside the porcelain (T3) to acquire temperature readings by time. For fast cooling, the furnace was opened immediately after the holding time and switched off afterward. Slow cooling was determined by opening the furnace when it reached 50 °C bellow the Tg. Axially-symmetric crown-like models were constructed to perform a simulation of time-dependent thermal stresses using finite element analyses (FEA). Time-dependent temperature equations from thermocouples were set as boundary conditions for surfaces of the model. Coefficient of thermal expansion, density, shear modulus, heat capacity and Tg dependency on cooling rate were considered for the porcelain simulation (visco-elastic above Tg). Porcelain below the Tg and the framework materials were considered to behave elastically. The cooling rates at Tg range were 20 °C/min and 900 °C/min for slow and fast cooling. During slow cooling, different thermocouples showed similar temperatures for both zirconia and metal crowns. Remarkable temperature gradients were observed for the fast cooled all-ceramic crown (T1-T4 = 100 °C) and, of lower magnitude, for PFM (T1-T4 = 30 °C). FEA results showed differences... (Complete abstract click electronic access below) / Doutor
219

Efeito do tipo e do posicionamento de reforço estrutural de sobredentaduras implanto-suportadas na transmissão de cargas aos implantes = Effect of the type and design of structural reinforcements of implant-supported overdentures in the stress transmission onto implants / Rodolfo Sommer Bittencourt ; orientador, Rodrigo Nunes Rached / Effect of the type and design of structural reinforcements of implant-supported overdentures in the stress transmission onto implants

Bittencourt, Rodolfo Sommer January 2009 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2009 / Inclui bibliografias / Este estudo avaliou o efeito de reforços estruturais de fibra de vidro e de metal fundido, bem como diferentes desenhos de posicionamento da fibra de vidro, no padrão de transmissão de cargas aos implantes em um modelo de sobre dentadura implanto-suportad / This study evaluated the effect of glass fibers and cast metal reinforcements, and different designs of the glass fibers reinforcement, in the patterns of force transmission onto the implants in an implant-supported overdenture model. Two titanium implant
220

Estudo clínico de técnica de reposicionamento do bloco ósseo e implantes em região anterior de maxila / Clinical study of implant-bone block repositioning technique in anterior region of maxilla

Osterne, Rafael Lima Verde 08 December 2016 (has links)
OSTERNE, R. L. V. Estudo clínico de técnica de reposicionamento do bloco ósseo e implantes em região anterior de maxila. 2016. 78 f. Tese (Doutorado em Odontologia) - Faculdade de Farmácia, Odontologia e Enfermagem, Universidade Federal do Ceará, Fortaleza, 2016. / Submitted by Erika Fernandes (erikaleitefernandes@gmail.com) on 2017-02-07T16:06:07Z No. of bitstreams: 1 2016_tese_rlvosterne.pdf: 8928902 bytes, checksum: d9707b7762617738f1015f80747f1ebb (MD5) / Approved for entry into archive by Erika Fernandes (erikaleitefernandes@gmail.com) on 2017-02-07T16:07:28Z (GMT) No. of bitstreams: 1 2016_tese_rlvosterne.pdf: 8928902 bytes, checksum: d9707b7762617738f1015f80747f1ebb (MD5) / Made available in DSpace on 2017-02-07T16:07:28Z (GMT). No. of bitstreams: 1 2016_tese_rlvosterne.pdf: 8928902 bytes, checksum: d9707b7762617738f1015f80747f1ebb (MD5) Previous issue date: 2016-12-08 / Vertical alveolar bone atrophy represents a challenge for reconstruction, especially when the esthetic zone of the maxilla is involved. When reconstruction is not achieved, a good esthetic outcome is rarely obtained. The aim of this retrospective study was to asses the outcome of implant-bone block movement, after segmental osteotomy in the maxillary aesthetic region in patients with vertical alveolar bone atrophy. Patients with vertical alveolar bone atrophy who underwent repositioning of the bone-implant block segment in the maxillary aesthetic region with a minimum of 6 months of follow-up were selected. Outcome measures were the success rate of the implant, complications after the surgical procedure, amount of vertical bone augmentation, papilla formation, keratinized mucosal band height and patient satisfaction analysis. Nine patients were included in the study, all with multiple implants, totaling 25 implants. The mean vertical bone augmentation was 4.9 mm (3.0-8.4 mm), and only 1 implant failure occurred. A statistically significant improvement in papilla formation was observed after surgery, leading to a good aesthetic result. More than 2 mm of height of keratinized mucosa was observed in 6 patients, and also a high satisfaction and acceptance to the treatment. After data evaluation, it was concluded that the technique presented can reconstruct vertical alveolar bone atrophy, with a high implant survival rate in a short period of follow-up, improving the aesthetic-functional result with a good acceptance by the Patients / Atrofia óssea alveolar vertical representa um desafio para a reconstrução e reabilitação oral, especialmente quando envolve a zona estética da maxila. Quando a reconstrução óssea não é realizada, um bom resultado estético dificilmente é obtido. O objetivo deste estudo retrospectivo foi avaliar o resultado do reposicionamento do bloco osso-implante, após a osteotomia segmentar em pacientes com atrofia óssea alveolar vertical na região estética de maxila. Para a realização deste trabalho, foram selecionados pacientes com atrofia óssea alveolar vertical que se submeteram à reposicionamento do segmento de bloco osso-implante na região estética maxilar com um mínimo de 6 meses de acompanhamento. As variáveis avaliadas foram o índice de sucesso do implante, complicações após o procedimento cirúrgico, quantidade de aumento ósseo vertical, formação da papila, altura da faixa de mucosa ceratinizada e a análise de satisfação do paciente. Nove pacientes foram incluídos no estudo, todos com implantes múltiplos, totalizando 25 implantes. A média de aumento ósseo vertical foi de 4,9 mm (3,0-8,4 mm), e apenas 1 falha de implante ocorreu. Uma melhora estatisticamente significativa na formação de papila foi observada após a cirurgia, levando a um bom resultado estético. Mais de 2 mm de altura de mucosa ceratinizada foi observado em 6 pacientes, e também uma alta satisfação e aceitação ao tratamento. Após a avaliação dos dados concluiu-se que, a técnica apresentada possui a capacidade de reconstruir atrofia óssea alveolar vertical, com uma elevada taxa de sobrevivência de implantes em período curto de acompanhamento, melhorando o resultado estético-funcional com uma boa aceitação por parte dos pacientes.

Page generated in 0.0783 seconds