• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 17
  • Tagged with
  • 17
  • 17
  • 17
  • 17
  • 10
  • 10
  • 10
  • 9
  • 9
  • 9
  • 9
  • 7
  • 5
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Distribuição das tensões geradas ao redor de implantes osseointegrados de diferentes conexões cone morse : análise fotoelástica e pelo método dos elementos finitos /

Anami, Lilian Costa. January 2011 (has links)
Orientador: Fernando Eidi Takahashi / Banca: Alexandre Luiz Souto Borges / Banca: Cristiane Aparecida de Assis Claro / Resumo: O objetivo deste trabalho foi avaliar a localização e distribuição das tensões geradas ao redor de implantes com pilares protéticos de diferentes conexões cone Morse através da análise fotoelástica (AFE) e do método dos elementos finitos (MEF). Para o MEF, implante e pilares protéticos de diferentes conexões cone Morse (hexagonado e sólido) foram digitalizados pela técnica da microtomografia computadorizada e, com auxílio de softwares computacionais foi realizada a modelagem da malha tridimensional e o carregamento dos objetos. Foi realizada a caracterização das propriedades mecânicas da resina fotoelástica. Foram simulados blocos com propriedades mecânicas de osso cortical e trabecular e de resina fotoelástica. A AFE foi realizada a partir de blocos de resina fotoelástica onde foram incluídos os implantes aparafusados aos diferentes pilares protéticos. Estes blocos foram confeccionados a partir de um bloco prototipado do modelo utilizado no MEF. Os corpos-deprova foram imersos em um recipiente com óleo mineral e o conjunto foi observado no polariscópio circular com dispositivo de aplicação de cargas acoplado e recebendo a mesma carga, em sentido e posição iguais. Foi feita análise descritiva para as imagens obtidas em ambas as metodologias onde observou-se que: as imagens obtidas no MEF apresentaram distribuição de tensões bastante similar entre os dois modelos com diferentes pilares protéticos. Foram observadas diferenças entre a distribuição das tensões em blocos ósseo e de resina; As imagens obtidas na AFE se assemelharam às obtidas em MEF com bloco de resina. As imagens da AFE também foram analisadas quantitativamente, por comparação a valores atribuídos às franjas. A concordância interobservadores foi conferida pelo teste de Dahlberg. Concluiu-se que o Pilar Sólido transfere cargas mais homogeneamente para o osso adjacente ao implante... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The goal of this study was to evaluate the location and distribution of stresses generated around implants with different Morse taper connections abutments by photoelastic (PA) and finite element analysis (FEA). For FEA, implant and abutments with different Morse taper connections (hexagonal and solid) were scanned by computerized microtomography technique. The tridimensional mesh was modeled and the objects were loaded with the help of computer software. Photoelastic resin was characterized by mechanical properties. Trabecular and cortical bone and photoelastic resin blocks were simulated with their respective mechanical properties. The PA was performed with photoelastic resin blocks where implants were included and the different abutments were bolted. These blocks were made from a prototyped block of model used in FEA. Specimens were immersed in a mineral oil container and it was observed in the circular polariscope with the application device attached, where loads were received on same charge, on equal direction and position. Images obtained in both methodologies were descriptively analyzed where it was that: FEA images showed very similar stress distribution between two models with different abutments. Differences were observed between stress distribution in bone and resin blocks; PA images resembled those obtained on resin block FEA. PA images were also quantitatively analyzed by comparing the values assigned to fringes. Inter-observer agreement was given by Dahlberg test. It was concluded that solid abutment distributes loads more evenly to bone adjacent to implant compared with hexagonal abutment, for both analysis methods employed. Among the methodologies employed, it was observed that the PA has generated very similar results to those obtained in FEA with resin block, but different to those obtained in FEA when the clinical condition of the bone block was simulated / Mestre
2

Estudo de preparos e da forma da infraestrutura na distribuição de tensões em prótese parcial fixa /

Yamamoto, Eron Toshio Colauto. January 2011 (has links)
Resumo: O objetivo do estudo foi verificar o comportamento de prótese fixa de três elementos confeccionada em Zircônia e dos dentes suportes quando são utilizados diferentes preparos dos dentes suportes e diferentes formas da infra-estrutura. Simulou-se a ausência do segundo pré-molar superior e realizou-se preparos do tipo ocluso-proximal, proximal-ocluso-proximal, preparo para overlay e para coroa total nos dentes suportes. Utilizou-se dois tipos de formato de conector, o convencional e em forma de arco. Os modelos tridimensionais foram realizados em softwares CAD Rhinoceros® e 3D Studio Max®. Os modelos tridimensionais simularam uma secção da maxila na região entre primeiro pré-molar e primeiro molar e foram compostos por osso medular e cortical, ligamento periodontal, dentina e esmalte. Foi realizada análise de elementos finitos, as análises de tensões foram processadas no programa Ansys®. Os resultados foram apresentados por meio de mapas de cores de tensão/deformação, com a distribuição de tensões e valores numéricos. Os diferentes preparos dos dentes suportes não influenciaram na distribuição de tensões nos dentes suportes. O preparo de coroa total foi o único preparo que diminui a tensão sobre a infra-estrutura. O formato do conector foi significativamente diferente. O conector em forma de arco distribui melhor as tensões na infra-estrutura do que o conector convencional / Abstract: The aim of this study was to investigate the behavior of three elements fixed partial denture made of three elements made of Zirconia and support teeth when use different preparations of the support teeth and different forms of framework. Simulated the absence of the superior second premolar and the support teeth preparation was occlusal-proximal, proximal-occlusal-proximal, overlay preparation and full crown. We used two types of connector format, the conventional and arc-shaped. The three-dimensional models were made in Rhinoceros CAD software and 3D Studio Max. The model was composed with maxillary first premolar and first molar, cortical and medullary bone, periodontal ligament, dentin and enamel. Analyses of stresses were processed in the program ANSYS ®. The results were presented in color maps of stress / strain, with the stress distribution and numerical values. The different preparations of the support teeth didn't influence the stress distribution in supppot teeth. The preparation of full crown was the only preparation that reduces the strain on the infrastructure. The shape of the connector was significantly different. The arch-shaped connector was better than conventional connector in the framework stress distribution / Orientador: Clóvis Pagani / Coorientador: Eduardo Galera da Silva / Banca: Eduardo Shigueyuki Uemura / Banca: Rubens Corte Real de Carvalho / Banca: Pedro Yoshito Noritomi / Banca: Daniel Maranha da Rocha / Doutor
3

Efeito da espessura oclusal do cimento e da sua união à cerâmica na resistência à fratura de coroas CAD/CAM: método de elementos finitos e testes monotônicos /

May, Liliana Gressler. January 2010 (has links)
Orientador: Marco Antonio Bottino / C0-orientador : Alvaro Della Bona / Banca: Luiz Felipe Valandro / Banca: Renata Marques de Melo Marinho / Banca: Ricardo Marins de Carvalho / Banca : Dolores Ribeiro Ricci Lazar / Resumo: Neste estudo avaliou-se a influência da espessura oclusal do cimento e de sua união à cerâmica na resistência à fratura de coroas CAD/CAM. O software COMSOL Multiphysics® foi utilizado para análise de elementos finitos (AEF) em modelos axi-simétricos bidimensionais de coroas de cerâmica vítrea estilizadas, com espessura oclusal de 1,5 mm, cimentadas à troqueis de material análogo à dentina quanto ao módulo elástico e potencial de união à resina composta (NEMA G-10 International Paper, USA). Variou-se as espessuras oclusais de cimento resinoso de 50 a 500 μm. Uma carga de 500 N foi aplicada com um pistão de extremidade circular plana (2 mm de diâmetro) sobre as coroas. A contração de polimerização do cimento foi simulada através de contração térmica. O contato entre cimento e cerâmica foi configurado para "união" e "ausência de união". O contato cimento-troquel foi sempre do tipo "união". As tensões dadas pela AEF foram utilizadas para o cálculo de cargas para fratura, levando-se em conta os efeitos deletérios da usinagem e do condicionamento ácido relatados na literatura. As coroas (Mark II, Vita Zhanfabrik, Germany) foram usinadas (CEREC InLab, Sirona, Germany), condicionadas e cimentadas (Multilink Automix, Ivoclar, Lietchstein) à troqueis de NEMA G-10 (n=6). Para a produção de corpos-de-prova na condição "ausência de união", aplicou-se uma fina película de poli(dimetilsiloxano) 30,000 cSt na superfície interna das coroas. As coroas foram submetidas à carregamento de 5N/s, com pistão de NEMA G-10, de extremidade plana e 2 mm de diâmetro. As fraturas radiais foram detectadas por sensor acústico. A magnitude das tensões resultantes da contração de polimerização dependeram da condição de união à cerâmica e da espessura oclusal de cimento. As cargas médias para fratura (N) de coroas com "união" ao cimento foram... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: In this study the influence of the occlusal cement thickness and its bonding to ceramic on the stresses and failure-loads of CAD/CAM crowns were evaluated. The software used for finite element analysis (FEA) was COMSOL Multiphysics®. Bi-dimensional axially symmetric models simulated stylized feldspathic crowns (1.5 mm occlusal thickness) with resin cement layers of 50 μm, 100 μm, 300 μm and 500 μm on dentin analog (NEMA G-10, International Paper, USA) under 500 N loading (2 mm diameter piston). Polymerization shrinkage of the cement layer was simulated as thermal contraction. Ceramic-cement interface was either bonded or not; cement-dentin was always bonded. Stress data were used for load-to-fracture predictions, using literature strengths accounting for milling and acid etching. Mark II® (Vita Zahnfabrik) crowns were milled (Cerec InLab®, Sirona), etched and cemented (Multilink Automix®, Ivoclar) to dentin analogs (NEMA G-10) (n=6). Non-bonding was achieved by applying a thin layer of 30,000 cSt poly(dimethylsiloxane) on the internal surface of the crowns. Crowns were loaded (5N/s) beneath a 2mm flat G-10 piston and radial cracks were detected acoustically. Stress magnitude resulting after cement shrinkage and loading depended on the bonding condition and on the cement thickness. Average failure loads (N) of bonded crowns were: 673.5 N for 50μm-cement thickness and 300.6 N for 500 μm. For non-bonded crowns, failure loads were 308,3 N, for 50 μm cement thickness and 233,3 N, for 500 μm. Bonded crowns presented failure loads at least two times higher than non-bonded, for 50 μm cement thickness, both experimentally and by FEA-based predictions. The benefit of bonding was lost when the cement was thicker than 500 μm. The resistance to fracture decreased with the cement thickness. Calculated loads based on FEA stresses and experimental data were comparable for the evaluate... (Complete abstract click electronic access below) / Doutor
4

Avaliação da resistência á flexão e determinação das propriedades mecânicas de resinas compostas e sua aplicação no método dos elementos finitos /

Piccioni, Máyra Andressa Rodrigues Valinhos. January 2010 (has links)
Orientador: José Roberto Cury Saad / Banca: Pedro Yoshito Noritomi / Banca: Edson Alves de Campos / Resumo: O Método de Elementos Finitos (MEF) constitui-se de uma ferramenta de amplo uso que permite, em computador, simular condições específicas em um material e determinar sua resposta para essas condições. O MEF pode ser utilizado em diversas áreas das ciências e, devido à sua grande aplicabilidade e eficiência, trabalhos com esta metodologia têm sido realizados nas diversas especialidades odontológicas, quando se deseja analisar comportamento mecânico. O objetivo deste trabalho foi determinar a resistência à flexão de resinas compostas "in vitro", suas propriedades mecânicas e comprovar a aplicabilidade do Método dos Elementos Finitos nas mesmas. As resinas compostas selecionadas para esse trabalho foram: Nano-híbrida (Tetric NCeram - Ivoclar Vivadent), Nanoparticulada (Filtek Z350 - 3M Espe) e Microparticulada (Heliomolar - Ivoclar Vivadent). A primeira etapa do trabalho foi a execução do ensaio de resistêcia à flexão segundo a norma ISO no 4049:1988 no qual os corpos de prova foram confeccionados usando uma matriz metálica. O material restaurador foi inserido e acomodado na cavidade da matriz até o preenchimento com mínimo excesso. Após o preenchimento da matriz, a resina composta foi fotoativada. Após a fotopolimerização, o corpo de prova permaneceu em repouso, para em seguida, ser cuidadosamente separado da matriz e imerso em água destilada e em seguida polido. Posteriormente, foram armazenados em água destilada, à temperatura de 37oC, por 24 horas. Os espécimes foram retirados da água, secos, e suas dimensões verificadas e inseridas na fórmula para o cálculo da resistência à flexão. Então, o teste de resistência à flexão foi executado. A segunda etapa do trabalho consistiu em determinar as propriedades mecânicas: coeficiente de Poisson e módulo de Young (módulo de elasticidade) dessas resinas compostas segundo a norma... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The Finite Element Method (FEM) consists of a tool of ample use that allows, in computer, to simulate specific conditions in a material and to determine their behavior for these conditions. The FEM can be used in various fields of sciences and, because of its wide applicability and efficiency, works with this methodology have been conducted in various dental specialties, when we want to analyze mechanical behavior. The aim of this study was to determine the flexural strength of composite resins in vitro, their mechanical properties and prove the applicability of the Finite Element Method in them. The composite resins were selected for this work were: Nano-hybrid (Tetric N-Ceram - Ivoclar Vivadent), nanoparticulated (Filtek Z350 - 3M Espe) and microparticulated (Heliomolar - Ivoclar Vivadent). The first stage of this work was the flexural strenght test according to ISO 4049:1988 where the specimens were prepared using a metal matrix. The restorative material was inserted and accommodated in the cavity of the matrix filling it with minimal excess. After filling the matrix, the composite was light cured. After curing, the specimen remained at rest, to then be carefully separated from the matrix and immersed in distilled water and then polished. Were subsequently stored in distilled water at a temperature of 37oC for 24 hours. The specimens were removed from water, dried, and its dimensions recorded and entered into the formula for calculating the flexural strength. Then, the test was performed. The second stage of the study was to determine the mechanical properties: Poisson's Ratio and Young's Modulus (Modulus of Elasticity) of these composites according to ASTM D638 - 01, where the specimens were prepared using a matrix and the material cured subjected to the test in a tensile testing machine. The third stage of this work was to generate a CAD model with the mechanical properties:... (Complete abstract click electronic access below) / Mestre
5

Sistemas adesivos autocondicionantes : estudo micromecânico da interface de união através do método dos elementos finitos tridimensional /

Anchieta, Rodolfo Bruniera. January 2010 (has links)
Resumo: Introdução: Embora os sistemas adesivos autocondicionantes se caracterizem por desmineralizar e infiltrar a dentina simultaneamente, a presença de dentina alterada abaixo da camada híbrida tem sido reportada, sugerindo comportamento mecânico distinto. Proposição: Avaliar por meio do método dos elementos finitos tridimensional a influência da espessura da dentina parcialmente alterada no comportamento micromecânico de dois sistemas adesivos autocondicionantes. Materiais e Métodos: Foram elaborados 5 micro-modelos (M) simulando a interface dentina/adesivo (d/a) (82x41x41 μm), sendo: M1-representação da interface d/a baseada em sistema adesivo convencional de 2 passos; M2-representação de um sistema adesivo autocondicionante de 2 passos. Nos M3, M4 e M5 representação de um sistema adesivo autocondicionante de 1 passo, variando a espessura da camada de dentina parcialmente alterada em 0, 1,5 e 3 μm, respectivamente. Os modelos foram considerados isotrópicos, homogêneos e linearmente elásticos. A base de todos os modelos foi fixada nos eixos x, y e z, sendo aplicado um carregamento em tração (90º; 0,03 N) na face superior da resina composta. A análise numérica foi realizada para a obtenção da tensão principal máxima ( max). Resultados: o pico da max (MPa) foi encontrada no M5 (79,5), seguido do M4 (78,0) e do M3 (70). O topo dos tags foi o local mais solicitado em todos os modelos. Conclusão: O aumento da espessura da dentina parcialmente alterada aumentou a tensão na interface d/a; a ausência desta camada contribuiu para a menor concentração de tensão; o topo dos tags foi o local mais exigido na interface d/a. / Abstract: Introduction: Although the self-etching adhesives are characterized by etching and infiltrating simultaneously the dentin, the presence of an altered dentin layer has been showed by literature, which might show specific mechanical behavior. Proposition: To evaluate through 3-D finite element analysis the influence of the partially altered dentin thickness on the micromechanical behavior of the self-etch adhesives. Materials and Methods: 5 micro-models (M) were developed for simulating the dentin/adhesive (d/a) interface (82x41x41 μm): M1-representation of the d/a interface based on 2 steps conventional adhesive system; M2-d/a interface based on 2 steps self-etch adhesive system M3, M4 and M5 - d/a interface based on all-in-one adhesive system, varying the thickness of the partially altered dentin (0, 1.5 and 3 μm, respectively). All the models were considered isotropic, homogeneous and lineally elastic. The bottom of all the models were constrained in the axes x, y and z. A tensile load (90o; 0.03N) was applied on the top of the composite resin. The numeric analysis was accomplished, being obtained the maximum principal stress ( max). Results: The pick of max (MPa) was found in M5 (79.5), followed by M4 (78.0) and M3 (70). The top of the resin tags was the most requested place in all models. Conclusion: The increase of the partially altered dentin thickness raised the max in the d/a interface; the absence of this layer contributed to the smallest tension concentration; the top of the tags showed higher stress concentration. / Orientador: Eduardo Passos Rocha / Coorientador: Renato Herman Sundfeld / Banca: Paulo Henrique dos Santos / Banca: André Figueiredo Reis / Mestre
6

Sistemas adesivos convencional e autocondicionante : análise micromecânica tridimensional da interface dentina-adesivo /

Martin Júnior, Manoel. January 2008 (has links)
Orientador: Eduardo Passos Rocha / Banca: Marco Antonio Luersen / Banca: Renato Herman Sundfeld / Banca: Marcelo Giannini / Banca: Washington Rodrigues Camargo / Resumo: OBJETIVO: Avaliar a distribuição das tensões na interface dentina-adesivo variando o sistema adesivo, convencional e autocondicionante, através do método dos elementos finitos tridimensional. MATERIAL E MÉTODO: Foram elaborados 4 modelos no programa Solidworks 2007, sendo: Mc - representação de um espécime em dentina (41x41x82 μm) restaurado com resina composta (RC), apresentando camada de adesivo, camada híbrida (CH), TAGs, dentina peri-tubular, dentina intertubular parcialmente desmineralizada, dentina intertubular e prolongamento odontoblástico, simulando a formação da CH segundo o sistema adesivo convencional; Mr - idêntico ao Mc, com ramificações laterais do infiltrado do adesivo; Ma - idêntico ao Mc, sem TAGs, e com "smear plug", simulando o sistema adesivo autocondicionante; Mat - idêntico ao Ma, com TAGs. Os modelos foram considerados isotrópicos, homogêneos e linearmente elásticos e a análise numérica foi realizada no ANSYS Workbench 10.0 para obtenção da máxima tensão principal (MAX) após aplicação de força de tração de 0,03 N perpendicular à superfície da RC. A base de todos os modelos foi fixada nos eixos x, y e z. RESULTADOS: A MAX foi maior para o sistema convencional. A presença da ramificação lateral aumentou a MAX na CH para o sistema convencional. Os TAGs modificaram a distribuição da MAX na camada de adesivo para o sistema autocondicionante. CONCLUSÃO: A CH para o sistema convencional apresentou maior MAX em comparação ao sistema autocondicionante. A presença das ramificações laterais do adesivo aumentaram a tensão na CH para o sistema convencional. / Abstract: OBJECTIVE: The aim of this study was to evaluate the stress distribution in the hybrid layer varying the adhesive system (total each and self-etching systems) using three-dimensional finite element analysis (FE). METHODS: 4 FE models (M) were developed in Solidworks 2007: Mc - representation of a specimen of dentin (41x41x82 μm) restored with composite resin (RC), showing the adhesive layer, hybrid layer (HL), TAGs, peri-tubular dentin, intertubular dentin in order to simulate simulating the HL according to the total-etch adhesive system; Mr - similar to Mc, with lateral branches of the adhesive; Ma - similar to Mc, without TAGs and showing the "smear plug" in order to simulate the environment for the self-ethcing adhesive system; Mat - similar to Ma, with TAGs. The models were considered isotropic, homogeneous and linearly elastic and numerical analysis was performed in ANSYS Workbench 10.0 to obtain the maximum principal stress (MAX) after application of a tension force of 0.03N perpendicular to the surface of the RC. The botton of all models was fixed in x, y and z axis. RESULTS: The highest MAX in HL was observed in the total etching system. The lateral branches increased the MAX in HL. The TAGs had a little influence on the stress distribution in self-ethching system. CONCLUSION: The HL for the total-etch system showed MAX higher in comparison with the self-etch system. The presence of TAGs increased the MAX in the HL for the total-etch system. / Doutor
7

Análise da influência dos sistemas de retenção para overdentures implanto-retidas na distribuição interna das tensões, através do método de elementos finitos /

Tabata, Lucas Fernando. January 2005 (has links)
Resumo: No tratamento com overdentures o mecanismo de transmissão e distribuição das tensões geradas por cargas funcionais através dos sistemas de retenção e implantes ao osso não está bem documentado. A intensidade e a forma como esta tensão é transmitida e distribuída ao osso determina os locais e a amplitude da reabsorção óssea. O objetivo deste estudo foi analisar, através do Método de Elementos Finitos (MEF) bidimensional, as tensões geradas pelas overdentures e transmitidas aos sistemas de retenção, implantes e tecido ósseo adjacente. Foram construídos em computador, através do programa AutoCAD, três modelos matemáticos representativos de cortes frontais da mandíbula na região inter-caninos, sendo: modelo A (Controle), mandíbula edêntula suporte de prótese total convencional; modelo B, mandíbula edêntula, suporte de overdenture com dois implantes ferulizados por meio de barra e clipe plástico; modelo C, mandíbula edêntula, suporte de overdenture com dois attachments esféricos O'rings em dois implantes isolados. Para análise, foi aplicada carga vertical de 100N em três regiões distintas: nos incisivos centrais inferiores, no canino inferior esquerdo e no primeiro molar inferior esquerdo. Os mapas de tensão evidenciaram as máximas e mínimas tensões e foram agrupados de acordo com as situações clínicas simuladas, para análise dos efeitos dos sistemas de retenção sobre as estruturas de suporte. O modelo A apresentou menores valores de tensão máxima (10,928MPa) que os modelos B (74,244MPa) e C (78,454MPa) em relação aos tecidos de suporte, sendo que os maiores valores foram obtidos no modelo C, na região peri-implantar do osso cortical para os três carregamentos aplicados. Os resultados sugerem a ferulização dos implantes e a utilização do sistema de retenção barra-clipe quando se pretende ter distribuição otimizada de tensões no tratamento com overdentures implanto-retidas. / Abstract: on treatment with overdenture, the transfer and distribution mechanism of the stress generated by functional loads through retention system and implants to bone it is not well documented, The intensity and the manner how this stress is tranfered and distributed to bone determine the sites and amplitude of bone resorption. The objective of this study was to analyse, through Finite Element Analysis (FEA) bidimensional, the stress generated on overdentures and transfer to retention system, implants and surrounding bone tissue. Three mathematic models were made in computer, through AutoCAD software, representing a frontal mandibular slice of inter-canine... (Complete abstract click electronic access below) / Orientador: Wirley Gonçalves Assunção / Coorientador: Edson Antônio Capello Sousa / Banca: Eduardo Passos Rocha / Banca: Ricardo Faria Ribeiro / Banca: Wirley Gonçalves Assunção / Mestre
8

Influência da altura da coroa em implantes osseointegrados : estudo pelo método dos elementos finitos tridimensionais /

Moraes, Sandra Lúcia Dantas de. January 2011 (has links)
Resumo: Os implantes dentais têm sido usados extensivamente para a reabilitação de edentulismo total e parcial, com próteses fixas ou removíveis. Em detrimento das suas taxas de sucesso e previsibilidade, falhas ocorrem e são associadas a complicações biomecânicas. Entre os fatores biomecânicos podemos destacar uma proporção adequada entre comprimento do implante e superestrutura. Porém, pouco é encontrado sobre a influência da altura da coroa, o alcance do braço de alavanca e, conseqüentemente, a tensão no osso cortical e no osso trabecular. Apesar do aumento no uso de implantes, muito pacientes que necessitam dessa terapia ficam limitados devido à pouca altura óssea. Sistemas disponibilizam no mercado implantes curtos, onde procedimentos cirúrgicos invasivos poderiam ser evitados; nesses implantes, porém, é muito comum uma relação coroa/área implantada invertida. Desenvolveremos este trabalho em dois capítulos. O primeiro irá avaliar a influência de três alturas de coroas pré-estabelecidas, quando associadas a implantes de hexágono externo em todas as suas estruturas associadas. No segundo, avaliaremos a influência das mesmas alturas de coroas, associadas a implantes de hexágono externo e cone - morse, na distribuição das tensões no tecido ósseo. Para a primeira parte do trabalho, foram confeccionados três modelos tridimensionais, com auxilio dos programas de modelagem gráfica SolidWorks 2006 e Rhinoceros 4.0, além do programa InVesalius (CTI, São Paulo, Brasil), utilizado para gerar o modelo ósseo a partir de uma tomografia computadorizada. Cada modelo foi composto por um bloco ósseo, com um implante de 3,75 x 10,00mm (Conexão Sistemas de Prótese, São Paulo), com o tipo de conexão: hexágono externo, utilizando três alturas de coroas (10 mm; 12.5 mm e 15 mm), colocadas na plataforma oclusal (hexágono externo). Após geração ... (Resumo completo, clicar acesso eletrônco abaixo) / Abstract: The dental implants have been widely used for rehabilitation of partial and complete edentulism using fixed and removable prostheses. Despite the success rate and predictability, failures are reported and commonly associated with biomechanical complications. Among the biomechanical factors, an adequate proportion between the implant and superstructure dimensions should be established. However, there is little information about the influence of crown height and lever arm on stress in cortical and trabecular bone. Although the use of implants has increased, many patients are limited by insufficient bone height. Thus, some implant systems developed short implants to avoid invasive surgical procedures. Nevertheless, such implants present an inverted crown/anchored area ratio. The present study will be divided into two chapters. The first one will evaluate the influence of three pre-established crown heights attached to external hexagon implants on all structures. In the second chapter, it will be evaluated the influence of the same crown heights attached to external hexagon and morse taper implants on the stress distribution in bone tissue. Initially, three 3D models were fabricated using the softwares SolidWorks 2006 and Rhinoceros 4.0. The software InVesalius (CTI, Sao Paulo, Brazil) was also used to generate the bone model through a computed tomography. Each model was composed by a bone block with an external hexagon implant (3.75 X 10.0 mm) (Conexao Sistemas de Protese, Sao Paulo) and a crown with different heights (10 mm, 12.5 mm and 15 mm) attached to the implant platform (external hexagon). After generation of the geometries, the models were imported to the software FEMAP 10.0 (Siemens PLM Software Inc., USA) for pre- and post-processing of finite elements to generate the meshes as well as the loading and boundary conditions. Axial load of 200N and oblique load of 100N were ... (Complete abstract click electronic access below) / Orientador: Eduardo Piza Pellizzer / Coorientador: Jorge Vicente Lopes da Silva / Banca: Fellipo Ramos Verri / Banca: Regina Tamaki / Banca: Estevão Tomomitsu Kimpara / Banca: Cátia Maria Fonseca Guerra / Doutor
9

Análise da distribuição das tensões em restaurações cerâmicas sobre dente natural e implante por meio do método dos elementos finitos /

Freitas Júnior, Amilcar Chagas. January 2008 (has links)
Resumo: As restaurações cerâmicas têm proporcionado resultados satisfatórios estética e biomecanicamente. Porém, a comparação dos dados sobre a distribuição das tensões nos casos de diferentes restaurações suportadas por dente ou por implante é inconclusiva. O objetivo desse estudo foi avaliar, através da análise de elementos finitos bidimensional, a distribuição interna das tensões nos materiais e estruturas de suporte em função de duas possibilidades restauradoras em cerâmica (faceta laminada e coroa total) e dois tipos de suportes (dente natural e implante). Foram confeccionados 8 (oito) modelos (M) no programa AutoCad 2006, variando o tipo de suporte e restauração: MA (controle) - representação do incisivo central maxilar, hígido, seccionado sagitalmente; MB1, MB2 e MB3 - semelhantes ao MA, restaurados com faceta laminada pelo sistema IPS Empress, IPS Empress Esthetic e Laminado Procera, respectivamente; MC1 e MC2 - semelhantes ao MA, com coroa total pelo sistema IPS Empress 2 (MC1) e Procera AllCeram (MC2); MD1 e MD2 - porção coronária semelhante ao MC1 e MC2, respectivamente, com a presença de um implante osseointegrado (Sistema Bränemark - 4,3 X 15,0 mm) e pilar em zircônia. Para análise numérica (Ansys 10.0), os modelos foram carregados (C) sob duas condições (50N): C1 - 45º de inclinação com o longo eixo dental, no terço médio da face palatina; C2 - perpendicular à borda incisal. Adicionalmente, uma terceira condição foi adotada para o MA: C3 - 50N na borda incisal paralelo ao longo eixo dental. Foram obtidas a tensão equivalente de von Mises (σvM) e a máxima tensão principal em tensão (σmax.t) e compressão (σmax.c). Observou-se que C3 proporcionou a menor variação de svM no dente e estruturas de suporte quando comparada à C1 e C2. / Abstract: The ceramics restorations have provided excellent aesthetic and biomechanical clinical results. However, the data about the stress distribution in tooth and implant-supported restorations are inconclusive. Using two-dimensional finite element analysis, the purpose of this study was to evaluate the stress distribution in the materials and support structures based on two ceramics restorative possibilities (laminate veneer and ceramic crown) and two support structures (tooth and implant). 8 models (M) were built in the program AutoCAD 2006, varying the restorations and their support structures: MA (control) - an intact maxillary central incisor in sagittal cut; MB1, MB2 and MB3 - similar to MA, with laminate veneers of IPS Empress, IPS Empress Esthetic and Procera veneer, respectively; MC1 and MC2 - similar to MA, with a full crown of IPS Empress 2 (MC1) and Procera AllCeram (MC2); MD1 and MD2 - coronary portion similar to MC, with an osseointegrated implant (Bränemark System - 4.3 X 15.0 mm) and zircon abutment. To the numerical analysis (Ansys 10.0), the following loadings (L) were performed (50N): L1 - on the medium third of the lingual face, in 45º with the dental long axis; L2 - perpendicular to the incisal edge; L3 - 50N in the incisal edge parallel to the tooth long axis (only for the natural tooth). The von Mises equivalent stress (σvM) and maximum principal stress in tension (σmax.t) and compression (σmax.c) were obtained. It was observed that L3 provided the smallest variation of σvM in the tooth and support structures in comparison with L1 and L2. The beam3 elements used for the periodontal ligament modeling showed an appropriate behavior for parallel loading. In the MB and MC, the ceramics increased the σvM in the adhesive interface, mainly for Procera. In the models with implant, the IPS Empress2 showed higher σvM than that for Procera AllCeram. / Orientador: Eduardo Passos Rocha / Coorientador: Paulo Henrique dos Santos / Banca: Altair Antoninha Del Bel Cury / Banca: Wirley Gonçalves Assunção / Mestre
10

Restaurações inlays em cerâmicas feldspáticas injetadas em pré-molares : efeito da estratégia de cimentação e da ciclagem mecânica na resistência adesiva entre dentina e restauração /

Feitosa, Sabrina Alves. January 2011 (has links)
Orientador: Marco Antonio Bottino / Banca: Paulo Francisco Cesar / Banca: Luiz Felipe Valandro Soares / Resumo: O estudo avaliou o efeito da estratégia de cimentação e da ciclagem mecânica na resistência de união entre dentina e restauração. O tipo de falha dos espécimes foi classificado e a distribuição de tensões foi analisada pela simulação utilizando o método de análise por elementos finitos (MEF). Quarenta e oito (N= 48) pré-molares superiores foram preparados (cavidade tipo MOD) e 48 restaurações inlays de cerâmica feldspática foram obtidas. Os espécimes foram alocadas em 3 grupos, considerando a estratégia de cimentação (N= 16): 1- convencional (Grupos 1 e 2): sistema adesivo condicionamento total de passo único (tratamento da dentina), tratamento da superfície cerâmica com ácido fluorídrico (HF) e silano (S), e cimentação com cimento resinoso; 2- estratégia simplificada (grupos 3 e 4) utilizando o cimento resinoso autoadesivo RelyX U100 (3M) sem tratamento das superfícies da dentina e da cerâmica; 3- estratégia simplificada modificada (grupos 5 e 6) utilizando o cimento resinoso RelyX U100 associado ao tratamento de superfície com HF+S. Os dentes dos grupos 2, 4 e 6 não foram ciclados, enquanto que aqueles dos grupos 1, 3 e 5 foram submetidos a ciclagem mecânica (CM): 2.000.000 pulsos, carga de 100N sobre as cúspides (a restauração não recebeu carga), a 37 oC. Cada espécime foi seccionado de forma seriada para produzir corpos de prova em forma de barras dente-restauração-dente para serem submetidas ao teste de microtração. A região da fratura de cada espécime foi analisada e classificada. A distribuição de tensões em um modelo virtual simulando as condições do estudo in vitro, pelo método de elementos finitos, foi verificada. A Análise de Variância mostrou que: o efeito interação dos fatores não foi estatisticamente significante (a alteração da resistência de união em razão da ciclagem mecânica (CM) para a Estratégia ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The study evaluated the effect of the bonding strategy and mechanical cycling on the bond strength between dentin and inlay restoration. The specimens failure mode and stress distribution (Finite element analysis FEA) was analyzed. Forty-eight (n = 48) pre-molars were prepared (MOD cavity) and 48 feldspathic ceramic inlays restorations were obtained. Specimens (tooth-restoration) were allocated into three groups considering the bonding strategy (n = 16): 1 - Conventional (groups 1 and 2): one-step total etch adhesive system (dentin treatment), hydrofluoric acid (HF) and silane (S) ceramic surface treatment, cementation with resin cement, 2 - Simplified (groups 3 and 4): RelyX U100 (3M) adhesive resin cement without dentin and ceramic surface treatment; 3 - Simplified modified (groups 5 and 6): RelyX U100 associated with HF + surface treatment. Specimens from groups 1, 3 and were subjected to mechanical cycling (CM) - 2,000,000 pulses, 100N on the cusp, 37ºC. Each specimen was sectioned to produce tooth-restoration-tooth bars specimens (cross-sectional area: 1mm2) that were submitted to microtensile bond strength test. The fractured area of each specimen was analyzed. Stress distribution was analyzed by a virtual model simulating the in vitro study by FEA. Variance analysis showed that: factors effect interaction was not statistically significant (there was no statistically differences between strength bond values with CM from groups 1 and 3). Strategy effect was statistically significant (strategy 3 mean strength bond [5.59 MPa] was significantly higher than the strategy 1strength bond [3.44 MPa]). Predominant failure mode was cement-cohesive-type. Von Mises analysis showed stress concentration at cement near the marginal ridge / Mestre

Page generated in 0.1122 seconds