Spelling suggestions: "subject:"próteses"" "subject:"ortóteses""
71 |
Análise fotoelástica das tensões desenvolvidas nas diferentes estruturas de suporte e protéticas em próteses parciais removíveis de extremidades livres com encaixes / Photoelastic analysis of stresses developed in different support and prosthetic structures of distal-extension removable partial dentures with attachmentsMello, Pâmela Carbone 05 August 2011 (has links)
Uma prótese dental quando planejada, tem como objetivo manter o equilíbrio entre saúde e função do sistema estomatognático, preservar suas estruturas, proporcionar estética e conforto ao paciente durante o uso. Portanto, sabendo-se da repercussão que pode causar nos dentes suporte, o planejamento deve ser correto, evitando o estabelecimento de uma patologia mais severa no sistema suporte. O uso de encaixes em PPRs de extremidades livres se justifica pela melhora da estética e satisfação do paciente. A análise fotoelástica é uma técnica experimental para análise de tensões capaz de produzir resultados bastante confiáveis e fiéis aos parâmetros clínicos. Assim o presente estudo teve como objetivo avaliar a força de retenção simulando cinco anos de uso de três diferentes tipos de encaixes extracoronários: ASC 52: resiliente, movimento vertical/rotacional e retenção friccional ajustável; SR 3: semi-rígido, movimento rotacional e retenção friccional/mecânica, Swiss-Ex: rígido, retenção friccional/mecânica e as tensões desenvolvidas nas estruturas de suporte destas próteses. Para avaliar a retenção foi utilizada matriz metálica em Co-Cr, representando um hemi-arco inferior parcialmente desdentado com os dentes remanescentes 43/44 preparados para coroas totais e ausência dos dentes 45/46/47. Foram fundidas coroas totais em Ni-Cr com machos dos encaixes na distal do dente 44. Estruturas de PPR foram fundidas e as fêmeas dos encaixes capturadas. O total de corpos-de-prova foi 18 (6 por tipo de encaixe). Foram realizados 7205 ciclos de inserção/remoção a 20 ciclos/min, com o conjunto imerso em água deionizada (±37º C). Foram observados os valores de força (N) para t=0, ½, 1, 2, 3, 4 e 5 anos. Para análise estatística foi utilizado o modelo linear de efeitos mistos (efeitos aleatórios e fixos) que é utilizado na análise de dados onde as respostas de um mesmo corpo-de-prova estão agrupadas e a suposição de independência entre as observações num mesmo grupo não é adequada. O ajuste do modelo foi feito através do procedimento PROC MIXED do software SAS® 9.1. Houve diferença estatística significante (p=0,000) entre os grupos: ASC52(8,15±1,12N); SR 3(3,84±1,80N); Swiss-Ex(2,05±0,83N). Avaliando os tempos não houve diferença significante entre os encaixes ASC 52 e Swiss-Ex. Para o SR 3 a força diminuiu ao longo dos tempos. O ASC 52 proporcionou maior estabilidade na prótese e manteve a capacidade retentiva durante os 5 anos simulados. Para análise fotoelástica foi confeccionado um modelo mestre em plexiglass representando um hemi-arco inferior de extremidade livre com os dentes 43 e 44 preparados para coroa total e ausência do 45, 46 e 47. Foram fundidas coroas totais em Ni-Cr com machos dos encaixes na distal do dente 44. Estruturas de PPR foram fundidas e as fêmeas dos encaixes capturadas. Sobre a sela foram montados os dentes artificiais 45 e 46. Posicionou-se os dentes 43 e 44 preparados e com as raízes simulando o ligamento periodontal no molde do modelo mestre e verteu-se resina fotoelástica. As análises foram realizadas em 3 diferentes aplicações de força (15N) nas distais: pontual no dente 45 e 46 e simultânea nos dentes 44 e 46. Os encaixes semi-rígido e resiliente ciclados geraram mais tensão nos pontos mais distais localizados no rebordo e a aplicação de carga pontual na distal do dente 46 foi a que gerou menos tensão nos dentes pilares para todos os encaixes novos e ciclados. Projeto FAPESP 05/58363-5 / A planned dental prosthesis aims to maintain the balance between health and function of the stomatognathic system, preserving its structures, providing aesthetics and patient comfort during use. Therefore, knowing the repercussions that may result on the support teeth, it must be correctly planned to avoid the establishment of a more severe pathology in the support system. The use of distal-extension removable partial dentures with attachments is justified by the improved aesthetics and patient satisfaction. The photoelastic analysis is an experimental technique for analysis of stresses capable of producing reliable and faithful results to clinical parameters. Thus, this study aimed to evaluate the retention force of three different extracoronal attachments simulating five years of use: ASC 52: resilient, vertical/rotational movement and adjustable fictional retention; SR 3: semi-rigid, rotational movement and frictional/mechanical retention; Swiss-Ex: rigid, frictional/mechanical retention and the stresses developed in the support structures of these prostheses. To assess the retention a partially edentulous metallic matrix Co-Cr representing a lower hemi-ach was used with teeth 43/44 remaining prepared for crowns and lacking teeth 45/46/47. Crowns were cast in Ni-Cr, with male attachments on the distal of tooth 44. PPR structures were merged and the female attachments captured. The total sample was 18 (6 for each type). A total of 7205 cycles of insertion/removal were performed at 20 cycles/min with the set submerged in deionized water (±37°). Force values (N) for t = 0, ½, 1, 2, 3, 4, and 5 years were observed. The linear mixed effects model (random and fixed effects) that is used in data analysis where the responses of the same sample are grouped and the assumption of independence of observations within the same group is not appropriate was used for statistical analysis. The model adjustment was done using the PROC MIXED procedure of the SAS® 9.1 software. There was a significant difference (p =0,000) between groups: ASC 52 (8,15 ± 1,12N); SR 3 (3,84 ± 1,80N); Swiss-Ex (2,05 ± 0,83N). There was no significant difference in the time evaluation between the attachments ASC 52 and Swiss-Ex. The SR 3 force decreased over time. The ASC 52 provided greater stability and maintained the retentive capacity over the 5 year simulation. A Plexiglas master model representing a distal extension hemi-arch inferior with teeth 43 and 44 prepared for crowns and absence of teeth 45, 46 and 47 was made for photoelastic analysis. Crowns were cast in Ni-Cr, with male attachments on the distal of tooth 44. PPR structures were merged and the female attachments captured. Artificial teeth 45 and 46 were mounted on the saddle. Prepared teeth 43 and 44 with roots simulating the periodontal ligament were positioned in the master model and the photoelastic resin was poured. Analyses were performed in three different applications of force (15N) in the distal: specific on teeth 45 and 46 and simultaneously on teeth 44 and 46. Cycled semirigid and resilient attachments generated more tension on the most distal points located at the edge and load application on the distal of tooth 46 was the one that generated the least stress on the abutment teeth for all attachments, new and cycled.
|
72 |
Influência das desadaptações angulares unilaterais na distribuição de tensões da região peri-implantar de elementos unitários tipo UCLA submetidos a pré-carga e carga axial: estudo in vitro / Influence of the unilateral angular misfit in frameworks made of UCLA on the peri-implant strain distribution, subjected to preload and axial loadBianco, Vinicius Cappo 24 June 2013 (has links)
Atualmente, os implantes são utilizados em diversos tipos de tratamento na reabilitação oral. Para manutenção da osseointegração, é essencial que o conjunto prótese/implante/osso seja submetido a forças às quais estejam aptos a suportar. Os diferentes tipos de desadaptações das infraestruturas das próteses sobre implantes são fatores que podem contribuir para o aumento das tensões na região peri-implantar. Este estudo teve como objetivo avaliar a influência das desadaptações angulares unilaterais na distribuição de tensões na região periimplantar de pilares tipo UCLA, no momento da pré-carga e carga axial. Infraestruturas de CoCr, confeccionadas utilizando-se pilares tipo UCLA, foram divididas em quatro grupos: Grupo A (adaptado), Grupo B, Grupo C e Grupo D (50, 100 e 200 μm de desadaptação unilateral angular por vestibular, respectivamente). Cada grupo foi representado por quatro infraestruturas (n=4). Quatro implantes (4.1mm/15mm) foram posicionados em uma matriz metálica, onde posteriormente foi vazado o poliuretano (PU), com função de simular o tecido ósseo. Quatro extensômetros (strain gauges) foram posicionados na região vestibular, distal, lingual e mesial de cada implante, para aferir a quantidade de deformação; cada grupo foi posicionado em seu respectivo implante. Foram realizados dois testes: o teste de pré-carga com um torque de 32Ncm e o teste de carga com uma força axial estática de 300N. Cada infraestrutura foi sujeita aos dois testes, por cinco vezes. Para análise estatística dos dados, foram utilizados ANOVA (dois critérios) e o teste de Tukey (p<0,05). Os resultados mostraram que os grupos A e B tiveram menos deformação da região peri-implantar em ambos os testes, quando comparados aos grupos C e D. A estatística também mostrou que o Grupo A apresentou melhor distribuição de tensões em sua região, peri-implantar quando comparado aos outros três grupos (p<0,05). Como conclusões, este estudo mostrou que as desadaptações influem na distribuição das tensões da região peri-implantar e que quanto maior o nível de desadaptação, mais altas são as tensões geradas. / Nowadays implants are used in several kinds of oral rehabilitation treatments. For the osseointegration maintenance it is important that crow/implant/bone are subjected to forces which are able to withstand. Different kinds of misfit on the crown frameworks are factors that could lead to an increase of strain around the implanted bone. This study aimed to evaluate the influence of the unilateral angular misfit in frameworks made of UCLA on the peri-implant strain distribution, subjected to preload and axial load. Frameworks made of chrome-cobalt were fabricated on UCLA abutments and divided in 4 groups: Group A (no misfit), Group B, Group C, Group D (50, 100, and 200 of unilateral angular misfit by buccal side, respectively). Each group was represented for 4 frameworks (n=4). Four implants (4.1mm/15mm) were positioned in a metallic matrix which was subsequently poured the polyurethane (PU) to simulate the bone. Four strain gauges were positioned on the buccal, distal, lingual and mesial sides of each implant to assess the amount of strain, each group was connected on its respectively implant. It was performed 2 tests: the preload test with a 32Ncm torque and the load test by applying an axial force of 300N. Each framework was subjected to the both test five times. To the statistics analysis ANOVA (2 ways) and Turkeys test were performed. The results showed that the Groups A and B presented less deformation when compared to Groups C and D. The statistics also showed that the Group A presented better distribution of strain on its peri-implant bone when compared to the other three groups (p<0,05). In conclusion this study showed that misfit had influence on the strain distribution on the peri-implant bone and that strain increased on the Groups C and D which presented higher levels of misfit.
|
73 |
Titânio revestido com recobrimento de matriz híbrida contendo hidroxiapatita visando a diferenciação osteogênica de células-tronco mesenquimaisBoniatti, Rosiana January 2016 (has links)
O titânio comercialmente puro (Ti-Cp) e suas ligas destacam-se como biomateriais metálicos devido a sua biocompatibilidade sendo amplamente utilizados. Buscando aprimorar o sucesso clínico dos implantes de Ti-Cp em longo prazo, é necessário revestir a sua superfície, proporcionando uma eficiente ancoragem mecânica do implante com o tecido ósseo. Dentre os diversos revestimentos superficiais destacam-se os revestimentos híbridos orgânicos-inorgânicos à base de precursores alcóxidos de silício, obtidos via processo sol-gel. Para que ocorra uma satisfatória adesão do revestimento no substrato, precisa-se levar em consideração a natureza e a preparação da superfície metálica antes da aplicação deste revestimento. Na etapa inicial do trabalho, pré-tratamentos superficiais foram propostos previamente à aplicação dos revestimentos buscando aumentar a aderência entre o titânio e este revestimento híbrido. Utilizou-se três diferentes pré-tratamentos na superfície do Ti-Cp: o "piranha" (ácido sulfúrico e peróxido de hidrogênio), o "kroll" (ácido fluorídrico, ácido nítrico e água) e o "hidróxido de sódio". Em sequência, aplicou-se por processo de dip-coating sobre as superfícies tratadas, um revestimento híbrido produzido a partir dos precursores alcóxidos de silício tetraetoxisilano (TEOS) e metiltrietoxisilano (MTES), obtido pelo processo de sol-gel. Em uma segunda etapa, sobre a superfície do Ti-Cp com o pré-tratamento superficial que proporcionou uma maior aderência do revestimento híbrido ao titânio, aplicou-se por dip-coating, um revestimento híbrido à base de precursores alcóxidos de silício TEOS e MTES com adição de partículas de hidroxiapatita buscando aprimorar a diferenciação celular sobre o revestimento híbrido. O pré-tratamento com o hidróxido de sódio promove o melhor resultado dentre os pré-tratamentos, pois o revestimento híbrido aplicado posteriormente apresenta recobrimento regular e adesão ao substrato de Ti-Cp. Os resultados morfológicos por MEV-FEG mostraram um revestimento híbrido com boa dispersão da hidroxiapatita e um recobrimento regular e adesão ao substrato de Ti-Cp. Nos resultados biológicos Ti-Cp revestido com TEOS/MTES com a presença de partículas de hidroxiapatita obteve uma adesão celular semelhante ao Ti-Cp sem tratamento. Porém este mesmo revestimento não propiciou a proliferação e diferenciação celular. Os resultados indicaram que a combinação de fatores como a sua superfície hidrofóbica (91°) e a presença da hidroxiapatita no revestimento tornou a superfície desorganizada, acarretando em uma superfície com comportamento desfavorável para o desenvolvimento das células-tronco mesenquimais. / Commercially pure titanium (cp-Ti) and its alloys stand out among the metallic materials due to their biocompatibility being widely used in biomaterials. In order to improve the clinical success of cp-Ti implants in the long term, it is necessary to coat the surface, providing an efficient mechanical anchoring of the implant with the bone tissue. Among the various surface coatings are the hybrid coatings based on silicon alkoxide precursors, obtained by the sol-gel process, however, considering the nature and the preparation of the metal surface prior to the application of this coating. In the initial stage of the work, surface pre-treatments were proposed prior to the application of the coatings seeking to increase the adhesion between the titanium and this hybrid coating. Three different pretreatments were used on the cp-Ti surface: "piranha" (sulfuric acid and hydrogen peroxide), "kroll "(hydrofluoric acid, nitric acid and water) and "sodium hydroxide". Subsequently, a hybrid coating produced by the tetraethoxysilane silicon (TEOS) and methyltriethoxysilane (MTES) precursors obtained by the sol-gel process was applied by the dip-coating process onto the treated surfaces. In a second step, on the surface of the cp-Ti with the surface pretreatment that gave a greater adhesion of the hybrid coating to the titanium, dip-coating, a hybrid coating based on precursors silicon alkoxides TEOS and MTES with the addition of hydroxyapatite particles to enhance cell differentiation on the hybrid coating. Pretreatment with sodium hydroxide promotes the best result among the pre-treatments, since the hybrid coating applied afterwards presents regular coating and adhesion to the cp-Ti substrate. The morphological results by SEM-FEG showed a hybrid coating with good dispersion of the hydroxyapatite and a regular coating and adhesion to the cp-Ti substrate. In the biological results Ti-Cp coated with TEOS / MTES with the presence of hydroxyapatite particles obtained a cell adhesion similar to Ti-Cp without treatment. However, this same coating did not promote cell proliferation and differentiation. The results indicated that the combination of factors such as its hydrophobic surface (91°) and the presence of the hydroxyapatite encapsulated in the coating rendering the surface disorganized led to a surface with unfavorable behavior for the development of mesenchymal stem cells.
|
74 |
Avaliação clínica da eficácia dos métodos químico (peróxido alcalino) e mecânico (ultra-som) frente à propriedade de remoção do biofilme de próteses totais / Clinical evaluation of the efficacy on biofilm removal from complete denture of the chemical (alkaline peroxide) and mecanical (ultrasonic) methodsPatricia Costa Cruz 07 November 2007 (has links)
O objetivo deste trabalho foi avaliar clinicamente a capacidade de remoção do biofilme da prótese total dos métodos de higiene: químico (pastilha efervescente para imersão de próteses totais à base de peróxido alcalino), mecânico (aparelho ultra-sônico), e associado (pastilha efervescente + aparelho ultra-sônico). Oitenta pacientes (usuários de próteses totais superiores e inferiores) participaram de um período experimental de 21 dias e foram distribuídos em 4 grupos (n=20): 1) Controle - escovação das próteses com escova específica (Bitufo) 3 vezes ao dia (após café da manhã, almoço e jantar) com água; 2) Químico - escovação das próteses com escova específica (Bitufo) 3 vezes ao dia (após café da manhã, almoço e jantar) com água e imersão em recipiente contendo ½ copo de água morna e 01 pastilha efervescente Corega Tabs por 5 minutos; 3) Mecânico - escovação das próteses com escova específica (Bitufo) 3 vezes ao dia (após café da manhã, almoço e jantar) com água, e uma única agitação ultra-sônica por 15 minutos ao final do período experimental (21 dias); 4) Associado - associação dos métodos 2 e 3. Para a quantificação do biofilme, as superfícies internas das próteses totais superiores foram evidenciadas (vermelho neutro 1%), fotografadas em 45º (Canon EOS Digital Rebel), processadas (Adobe Photoshop 5.0) e as áreas (total da superfície interna e corada com biofilme) quantificadas (Image Tool 2.02). A porcentagem do biofilme foi calculada como a relação entre a área do biofilme multiplicado por 100 e a área da superfície total da base interna da prótese. Os resultados mostraram diferenças entre os métodos (teste de Kruskal-Wallis, significância de 0,05), com superioridade dos métodos químico (37.2), mecânico (35.2) e associado (29.1) sobre o controle (60.5). Como conclusão, a imersão em peróxido alcalino e o uso do ultra-som podem ser empregados como agentes auxiliares na higienização de próteses totais. / The aim of this study was to evaluate the hability of the biofilm removal from complete denture of the chemical (alkaline peroxide-effervescent tablets to complete denture immersion), mechanical (ultrasonic) and combined (association of the effervescent and ultrasonical methods) methods. Eighty patients that use upper and lower complete denture participated of the experimental period of 21 days and they were distibuted in 4 groups (n=20): 1) Control - brushing the dentures with especifc brush (Bitufo), 3 times a day (after breakfast, lunch and dinner) with water; 2) Chemical - brushing the dentures with especifc brush (Bitufo), 3 times per day (after breakfast, lunch and dinner) with water and immersion in a recipient containing warm water and 01 effervescent tablet of Corega Tabs for 5 minutes; 3) Mechanical - brushing the dentures with especific brush (Bitufo), 3 times a day (after breakfast, lunch and dinner) with water and only one ultrasonic vibration per 15 minutes in the end of the esperimental period (21 days); 4) Combined - association of the methods 2 and 3. To quantify the biofilm, the internal surfaces of the upper complete dentures were stained and photographed in 45º (Canon EOS Digital Rebel), processed (Adobe Photoshop 5.0) and the areas (total internal surface and stained with biofilm) quantified (Image Tool 2.02). The percentage of the biofilm was calculated by the relation between biofilm area multiplier by 100 and total area of the internal surface of the upper complete denture. The results showed diferences between the methods (teste de Kruskal-Wallis, significância de 0,05), with superiority of the chemical (37.2), mechanical (35.2) and combined (29.1) methods above control group (60.5). As conclusion, the immersion with alkaline peroxide and the use of ultrasonic vibration can be employed as auxiliary agents on the hygiene of complete dentures.
|
75 |
Análise fotoelástica das tensões desenvolvidas nas diferentes estruturas de suporte e protéticas em próteses parciais removíveis de extremidades livres com encaixes / Photoelastic analysis of stresses developed in different support and prosthetic structures of distal-extension removable partial dentures with attachmentsPâmela Carbone Mello 05 August 2011 (has links)
Uma prótese dental quando planejada, tem como objetivo manter o equilíbrio entre saúde e função do sistema estomatognático, preservar suas estruturas, proporcionar estética e conforto ao paciente durante o uso. Portanto, sabendo-se da repercussão que pode causar nos dentes suporte, o planejamento deve ser correto, evitando o estabelecimento de uma patologia mais severa no sistema suporte. O uso de encaixes em PPRs de extremidades livres se justifica pela melhora da estética e satisfação do paciente. A análise fotoelástica é uma técnica experimental para análise de tensões capaz de produzir resultados bastante confiáveis e fiéis aos parâmetros clínicos. Assim o presente estudo teve como objetivo avaliar a força de retenção simulando cinco anos de uso de três diferentes tipos de encaixes extracoronários: ASC 52: resiliente, movimento vertical/rotacional e retenção friccional ajustável; SR 3: semi-rígido, movimento rotacional e retenção friccional/mecânica, Swiss-Ex: rígido, retenção friccional/mecânica e as tensões desenvolvidas nas estruturas de suporte destas próteses. Para avaliar a retenção foi utilizada matriz metálica em Co-Cr, representando um hemi-arco inferior parcialmente desdentado com os dentes remanescentes 43/44 preparados para coroas totais e ausência dos dentes 45/46/47. Foram fundidas coroas totais em Ni-Cr com machos dos encaixes na distal do dente 44. Estruturas de PPR foram fundidas e as fêmeas dos encaixes capturadas. O total de corpos-de-prova foi 18 (6 por tipo de encaixe). Foram realizados 7205 ciclos de inserção/remoção a 20 ciclos/min, com o conjunto imerso em água deionizada (±37º C). Foram observados os valores de força (N) para t=0, ½, 1, 2, 3, 4 e 5 anos. Para análise estatística foi utilizado o modelo linear de efeitos mistos (efeitos aleatórios e fixos) que é utilizado na análise de dados onde as respostas de um mesmo corpo-de-prova estão agrupadas e a suposição de independência entre as observações num mesmo grupo não é adequada. O ajuste do modelo foi feito através do procedimento PROC MIXED do software SAS® 9.1. Houve diferença estatística significante (p=0,000) entre os grupos: ASC52(8,15±1,12N); SR 3(3,84±1,80N); Swiss-Ex(2,05±0,83N). Avaliando os tempos não houve diferença significante entre os encaixes ASC 52 e Swiss-Ex. Para o SR 3 a força diminuiu ao longo dos tempos. O ASC 52 proporcionou maior estabilidade na prótese e manteve a capacidade retentiva durante os 5 anos simulados. Para análise fotoelástica foi confeccionado um modelo mestre em plexiglass representando um hemi-arco inferior de extremidade livre com os dentes 43 e 44 preparados para coroa total e ausência do 45, 46 e 47. Foram fundidas coroas totais em Ni-Cr com machos dos encaixes na distal do dente 44. Estruturas de PPR foram fundidas e as fêmeas dos encaixes capturadas. Sobre a sela foram montados os dentes artificiais 45 e 46. Posicionou-se os dentes 43 e 44 preparados e com as raízes simulando o ligamento periodontal no molde do modelo mestre e verteu-se resina fotoelástica. As análises foram realizadas em 3 diferentes aplicações de força (15N) nas distais: pontual no dente 45 e 46 e simultânea nos dentes 44 e 46. Os encaixes semi-rígido e resiliente ciclados geraram mais tensão nos pontos mais distais localizados no rebordo e a aplicação de carga pontual na distal do dente 46 foi a que gerou menos tensão nos dentes pilares para todos os encaixes novos e ciclados. Projeto FAPESP 05/58363-5 / A planned dental prosthesis aims to maintain the balance between health and function of the stomatognathic system, preserving its structures, providing aesthetics and patient comfort during use. Therefore, knowing the repercussions that may result on the support teeth, it must be correctly planned to avoid the establishment of a more severe pathology in the support system. The use of distal-extension removable partial dentures with attachments is justified by the improved aesthetics and patient satisfaction. The photoelastic analysis is an experimental technique for analysis of stresses capable of producing reliable and faithful results to clinical parameters. Thus, this study aimed to evaluate the retention force of three different extracoronal attachments simulating five years of use: ASC 52: resilient, vertical/rotational movement and adjustable fictional retention; SR 3: semi-rigid, rotational movement and frictional/mechanical retention; Swiss-Ex: rigid, frictional/mechanical retention and the stresses developed in the support structures of these prostheses. To assess the retention a partially edentulous metallic matrix Co-Cr representing a lower hemi-ach was used with teeth 43/44 remaining prepared for crowns and lacking teeth 45/46/47. Crowns were cast in Ni-Cr, with male attachments on the distal of tooth 44. PPR structures were merged and the female attachments captured. The total sample was 18 (6 for each type). A total of 7205 cycles of insertion/removal were performed at 20 cycles/min with the set submerged in deionized water (±37°). Force values (N) for t = 0, ½, 1, 2, 3, 4, and 5 years were observed. The linear mixed effects model (random and fixed effects) that is used in data analysis where the responses of the same sample are grouped and the assumption of independence of observations within the same group is not appropriate was used for statistical analysis. The model adjustment was done using the PROC MIXED procedure of the SAS® 9.1 software. There was a significant difference (p =0,000) between groups: ASC 52 (8,15 ± 1,12N); SR 3 (3,84 ± 1,80N); Swiss-Ex (2,05 ± 0,83N). There was no significant difference in the time evaluation between the attachments ASC 52 and Swiss-Ex. The SR 3 force decreased over time. The ASC 52 provided greater stability and maintained the retentive capacity over the 5 year simulation. A Plexiglas master model representing a distal extension hemi-arch inferior with teeth 43 and 44 prepared for crowns and absence of teeth 45, 46 and 47 was made for photoelastic analysis. Crowns were cast in Ni-Cr, with male attachments on the distal of tooth 44. PPR structures were merged and the female attachments captured. Artificial teeth 45 and 46 were mounted on the saddle. Prepared teeth 43 and 44 with roots simulating the periodontal ligament were positioned in the master model and the photoelastic resin was poured. Analyses were performed in three different applications of force (15N) in the distal: specific on teeth 45 and 46 and simultaneously on teeth 44 and 46. Cycled semirigid and resilient attachments generated more tension on the most distal points located at the edge and load application on the distal of tooth 46 was the one that generated the least stress on the abutment teeth for all attachments, new and cycled.
|
76 |
Materialização do imaginário por meio da estética de próteses de membro superiorCaselas, Raissa Gonçalves 27 September 2018 (has links)
Submitted by Filipe dos Santos (fsantos@pucsp.br) on 2018-12-05T11:48:18Z
No. of bitstreams: 1
Raissa Gonçalves Caselas.pdf: 4140601 bytes, checksum: 39e478f743f8ad192024eec9ac3c9304 (MD5) / Made available in DSpace on 2018-12-05T11:48:18Z (GMT). No. of bitstreams: 1
Raissa Gonçalves Caselas.pdf: 4140601 bytes, checksum: 39e478f743f8ad192024eec9ac3c9304 (MD5)
Previous issue date: 2018-09-27 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / With the increasing insertion of 3D printing technologies in the industry, it becomes possible to develop new approaches for objects of different uses, allowing the creation of products highly adaptable to users, as well as the possibility of overcoming design barriers. Being aware of the limits of production and mechanical strength of materials as for lower limb prostheses when related to 3D printing, this research focused on the development of upper limb prostheses. Aiming to analyze the aesthetic and functional ways that the production of these prostheses has covered, were proposed case studies that sharpened the user's imagination and allowed them to be brought from the intangible to the palpable. Projects that were once considered to be impractical, with the technological advance are shown to be feasible, since CAD modeling with 3D printing opens new possibilities. Basing on the information sharing and using open source prosthesis designs, it was possible to attest to its reproducibility as well as the recurring aesthetic attributes, thus, two prostheses were printed and constructed with the use of additive manufacturing technology. Based on several authors from different areas, such as Lucia Santaella, Masahiro Mori, Vilem Flusser, João Teixeira, Chris Anderson and Kathryn Allan, as well as product development concepts, it was finally noticed that the aesthetics resulting from this union permeates the cyberpunk universe, introducing people who have physical disabilities not as "imperfect," but through technology, they can be like superhumans. Contrary to what was believed, prostheses showed a certain tendency towards robotization, admitting their inorganic nature and providing other means of personalization / Com a crescente inserção das tecnologias de impressão 3D na indústria, torna-se possível o desenvolvimento de novas abordagens para objetos de usos diversos, permitindo a criação de produtos altamente adaptáveis aos usuários, bem como a possibilidade de vencer barreiras projetuais. Tendo conhecimento dos limites de produção e de resistência mecânica dos materiais quanto as próteses de membro inferior quando relacionados à impressão 3D, esta pesquisa focou no desenvolvimento de próteses de membro superior. Buscando analisar os caminhos estéticos e funcionais que a produção dessas próteses tem cursado, foram propostos estudos de caso que aguçavam o imaginário do usuário e que permitiam trazê-los do intangível ao palpável. Projetos que outrora viam-se como sendo impraticáveis, com o avanço tecnológico se mostram realizáveis, pois a modelagem CAD junto a impressão 3D abrem novas possibilidades. Apoiando-se também no compartilhamento de informações e utilizando projetos de próteses open source, foi possível atestar sua reprodutibilidade, bem como os atributos estéticos recorrentes, assim, foram impressas e construídas duas próteses com a utilização de tecnologia de manufatura aditiva. Nos embasando em diversos autores de áreas distintas como, Lucia Santaella, Masahiro Mori, Vilem Flusser, João Teixeira, Chris Anderson e Kathryn Allan, além de conceitos de desenvolvimento de produtos, percebeu-se, por fim, que a estética que resulta dessa união permeia o universo do cyberpunk, apresentando as pessoas que possuem deficiências físicas não como “imperfeitas”, mas por meio da tecnologia, podem ser como super-humanos. Diferentemente do que se acreditava, as próteses apresentaram certa tendência à robotização, admitindo sua natureza inorgânica e propiciando outros meios de personalização
|
77 |
Modelamento médico: uma integração entre CAD, CAE, engenharia reversa e prototipagem rápida / Medical modeling: an integration among CAD, CAE, reverse engineering and rapid prototypingCoelho, Marco Antonio Oliveira 29 April 2003 (has links)
Modelamento médico é uma técnica utilizada por cirurgiões no auxílio da diagnose, comunicação com o paciente, estudos pré-operatórios, definição e simulação de procedimentos cirúrgicos, visando diminuir o tempo cirúrgico e de convalescença do paciente. Em aplicações mais recentes, esta técnica tem sido utilizada no desenvolvimento de próteses personalizadas, possibilitando que reconstituições de grande complexidade sejam feitas de maneira rápida e segura. Resumidamente, a técnica consiste em produzir um protótipo em terceira dimensão do tecido ou deformidade em estudo. Utiliza-se hoje de modernas tecnologias como tomografia computadorizada e prototipagem rápida entre outras, representando um exemplo significativo de integração entre diferentes áreas do conhecimento. Este trabalho apresenta e discute o modelamento médico no que se refere às suas aplicações, enfocando a integração entre as tecnologias de prototipagem rápida, engenharia reversa (RE) e projeto e engenharia assistidos por computador (CAD/CAE). É feita uma descrição dos procedimentos de geração dos modelos médicos usando técnicas de prototipagem rápida a partir de dados obtidos de tomografia computadorizada, e um estudo de sua precisão dimensional e geométrica. São explorados os recursos possibilitados pela integração com sistemas CAD/CAE, e apresentadas aplicações reais das técnicas na área de cirurgias craniofaciais, evidenciando as vantagens de sua utilização e validando os procedimentos propostos. / Medical modeling is a technique used by surgeons in the diagnosis, communication with the patient, preoperative studies, definition and simulation of surgical procedures. It helps to reduce the operative and convalescence time. It consists of producing a prototype in third dimension of the tissue or deformity in study. In some more recent applications, this technique has been used to develop customized prosthesis, enabling that quite complex reconstructions can be made in a safe and fast way. Nowadays, it uses modern technologies as the computer tomography and rapid prototyping, and it represents significant example of integration among different areas of the knowledge. This work presents the medical modeling and discusses its applications, with emphasis in the integration of the technologies of rapid prototyping, reverse engineering (RE) and computer aided design and engineering (CAD/CAE). It is made a description of the procedures to generate the medical models using rapid prototyping techniques starting from computer tomography data, and a study regarding the dimensional and geometric precision of the medical models generated by rapid prototyping. The advantages of the integration with CAD/CAE technologies are shown and a case study is developed aiming to validate the proposed procedures.
|
78 |
Análise do comportamento biomecânico por meio de elementos finitos, de próteses parciais fixas, apoiadas sobre diferentes conexões entre dente-implante / Fit evaluation on prefabricated abutments and transmitted stress to implants by I beam superstructures as a function of implants numberLencioni, Karina Albino 03 July 2015 (has links)
Limitações anatômicas, falhas na osseointegração, necessidade de esplintagem de dentes naturais com comprometimento periodontal podem levar a união dente-implante. Alguns autores relatam que a união com conexão da prótese semi-rígida pode causar a intrusão do dente natural, por esse motivo o uso de conexão da prótese em monobloco vem causando maior sucesso. Com isso o objetivo do trabalho é analisar a distribuição de tensão pelo método dos elementos finitos, em prótese sobre conexão dente-implante alterando o tipo de conexão da prótese, rígida e semi-rígida, e o tipo de conexão do implante, cone morse ou hexágono externo, em regiões de ligamento periodontal, osso periimplantar e conjunto prótese e implante. Para a realização do trabalho foi realizado o escaneamento dos dentes 45 e 46, através de um microtomógrafo (SkyScan, Kontich, Bélgica), as imagens em 3D dos implantes e componentes protéticos foram cedidas pela empresa Neodent (Curitiba, PR, Brasil). Nesse trabalho foram desenvolvidos quatro modelos tridimensionais todos eles representavam um hemiarcada mandibular direita com presença do dente 45 e ausência do dente 46 e 47, foram feitos modelos com implante com conexão hexagonal externa e prótese com conexão rígida ou semi-rígida, e modelos com implantes cone morse com prótese com conexão rígida ou semi-rígida. As modelagens foram realizadas no programa Rhinoceros 3D (Robert McNeel& Associates, EULA, EUA) o programa utilizado para análise dos elementos finitos foi o ABAQUS FEA (Simulia, Providence, RI, EUA).Os resultados mostraram que modelos com conexão do implante em hexágono externo geraram uma tensão de tração na distal do ligamento periodontal com presença de tensão de compressão da região apical do ligamento periodontal, sugerindo uma possível rotação do elemento dentário com posterior intrusão, independentemente do tipo de conexão protética. Já em modelos com implantes cone morse observamos uma maior distribuição de tensão no ligamento sugerindo até mesmo uma anulação da forças de tração, também independentemente do tipo de conexão da prótese. Foi observado também que próteses com implantes cone morse sofreram maior distribuição de tensão, que próteses com implantes hexágono externo, porém foi observado maior concentração de tensão na região de união pilar/implante nos dois tipos de implantes usados, não dependendo do tipo de conexão da prótese. Outro resultado observado foi um maior acúmulo de tensão no osso cortical que no osso medular, e também maior tensão no osso cortical em modelos com implante cone morse que em modelos com implante hexagonal externo, para os dois tipos de conexão da prótese. Com isso, concluímos que independentemente do tipo de conexão da prótese, o uso de implantes cone morse na união dente-implante gerou melhores resultados que o uso de implantes hexágono externo. / Anatomical limitations, failures in osseointegration, need for splinting of natural teeth with periodontal disease can lead to tooth-implant union. Some authors report that the union with the semi-rigid prosthesis connection can cause the intrusion of the natural tooth, therefore the use of the prosthesis connection monobloc is causing greater success. Thus the objective of this study is to analyze the stress distribution by finite element method, in denture on implant-tooth connection by changing the type of prosthesis connection, rigid and semi-rigid, and the type of implant connection, morse taper or external hexagon in areas of periodontal ligament, peri-implant bone and joint prosthesis and implant. To carry out the work was carried out scanning of teeth 45 and 46, through a microtomography (SkyScan, Kontich, Belgium), the 3D images of prosthetic implants and components were provided by Neodent company (Curitiba, Brazil). In this work we developed four-dimensional models they all represented a mandibular right hemi-arch with presence and absence of the tooth 45 of the tooth 46 and 47 models were made with implants with external hex connection and prosthesis with rigid or semi-rigid connection, and models with implants morse taper with prosthesis with rigid or semi-rigid connection. The modeling was performed in Rhinoceros 3D program (Robert McNeel & Associates EULA, USA) program used for finite element analysis was ABAQUS FEA (SIMULIA, Providence, RI, USA) .The results showed that implant connection with models in hexagon generated a distal external tensile stress in the periodontal ligament with presence of the apical region compressive stress of the periodontal ligament, suggesting a possible rotation of the tooth with subsequent intrusion, regardless of the type of prosthetic connection. Already in models with morse taper implants found a higher voltage distribution ligament even suggesting a reversal of traction, also regardless of the type of prosthesis connection. It was also observed that prostheses with morse taper implants suffered greater stress distribution, which aids with external hex implants, but there was a higher concentration of stress in the joining region pillar / implant in the two types of implants used, not depending on the type of connection prosthesis. Another result was observed a higher voltage accumulation in the cortical bone in the cancellous bone, and also higher voltage on cortical bone models in morse taper implant external hexagon implant models for the two types of prosthesis connection. Thus, we conclude that regardless of the type of prosthesis connection, using morse taper implants in implant-tooth union gave better results than the use of external hex implants.
|
79 |
Validação de uma máquina de testes de flexão rotacional e seus efeitos em implantes de hexágono externo e interno / Validation of a rotating bending machine and its effects on external and internal hexagon implantsOliveira Neto, Luiz Alves de 24 April 2013 (has links)
O sucesso do tratamento com implantes dentários depende do conhecimento teórico-prático do profissional, condições biológicas do paciente, e das propriedades mecânicas dos seus componentes. Dois testes de fadiga podem avaliar as propriedades mecânicas destes materiais: ensaios monotônicos unidirecionais e testes de flexão rotacional. A vantagem do dispositivo de flexão rotacional é o ensaio mais rápido que fornece dados relevantes e uma previsão mais realista da longevidade clínica. Oliveira-Neto (2011) avaliou o dispositivo de flexão rotacional desenvolvido por Ferreira (2010), e mostrou que componentes do dispositivo necessitavam ser revistos para assegurar melhor fixação do implante, controle de temperatura, frequência e permitir modificação do momento de força aplicado aos espécimes. O objetivo deste trabalho foi confeccionar e avaliar novos componentes para o dispositivo de flexão rotacional de Ferreira (2010) e avaliar seus efeitos em sistemas de implante de hexágono externo e interno. Os grupos testados foram: Aimplantes Hexagono Externo (HE) com munhão (UCLA); B- implantes HE com Pilar Cônico; C- implantes Hexagono Interno (HI) com munhão (UCLA); D- implantes HI com Pilar Cônico. O novo método consistiu em modificações no: porta implante, porta rolamento, centralizador do implante, material de fixação (resina acrílica). As amostras foram submetidas a ciclagem em torno do seu eixo longitudinal enquanto uma extremidade estava fixada em um mandril à 45o e a outra extremidade recebia a carga. O objetivo foi determinar o nível de carga em que 50% dos espécimes sobreviveram e 50% fraturaram antes de 106 ciclos girando a 16Hz. Assim, a resistência a fadiga (F50) foi determinada através da técnica staircase analysis. Após a ciclagem, os componentes que não apresentaram falhas tiveram o destorque de remoção mensurado eletronicamente, e todas as amostras foram analisadas através de microscópio eletrônico de varredura, radiografia e fotografia digital. Os resultados mostraram que os grupos UCLA têm maior resistência à fadiga. O sistema de HI-UCLA mostrou um desempenho mais estável, com uma resistência igual ao HE. Os grupos com Pilar Cônico apresentaram falhas clinicamente melhor, permitindo a substituição de componentes protéticos. Os danos mais graves ocorreram em ambos os grupos HE, com danos aos implantes. O método de desinclusão do implante da resina precisa ser revisto visando a obtenção de imagens sem artefatos. O dispositivo de Ferreira (2010) associado às modificações propostas por Oliveira-Neto permitiu a execução do ensaio de flexão rotativa em sistema de implantes com variadas configurações, produzindo resultados clinicamente relevantes. / Implant success depends on professional ability, patient biological conditions and also mechanical properties. Two fatigue tests can study implant mechanical properties: unidirectional bend-release fatigue testing and rotational fatigue testing. Advantages of rotational bending devices include faster tests that can generate relevant data and provide more realistic prediction of clinical performance. Oliveira- Neto (2011) evaluated a rotational bending device developed by Ferreira (2010), and showed its components need to be revised to ensure better implant fixation, temperature control, frequency and also enable to increase force moment. The aim of this study was fabricate and evaluate new components to Ferreiras device and it evaluate it effects in external and internal hexagon implant systems.Following groups were tested: A-external hex (EH) implants with UCLA abutment, B- EH implants with Conical Abutment, C- internal hex (HI) implants with UCLA abutment, D- IH implants with Conical Abutment. The new methodology consisted in changes on implant holder, bearing case, implant centralizer and bone material simulator (acrylic resin). Samples were spun around their long axes while being clamped into a 45o revolving collet on one end and loaded normal to their long axis on the other end. The aim was to determine the load level at which 50% of the specimens survived- and 50% fractured before 106 cycles at 16Hz. Fatigue resistance (F50) were determined using the staircase procedure. After cycling, torque of survival components were measured electronically, and all samples were analyzed by scanning electron microscopy, x-ray and digital photography. Results showed that UCLA groups have higher fatigue resistence. The IH-UCLA system showed more stable performance, with equal resistance to EH. Conical Abutment groups failure clinically better, allowing replacement of prosthetic components. The most severe damage occurred in both EH groups, with implant damages. Ferreiras device with Oliveira-Neto changes enabled to perform a rotating bending test on implant system in numerous configurations, producing clinically relevant results.
|
80 |
Análise microbiológica da vedação com selante industrial de microgaps nas diferentes conexões implantares: estudo in vitro / Microbiological analysis of the seal with industrial sealant on the microgaps in the different implant connections: in vitro studyTunes, Fábio Sanches Magalhães 29 June 2018 (has links)
A utilização de implantes osseointegráveis e componentes protéticos tornaram-se recursos muito viáveis à resolução de casos simples e complexos na odontologia reabilitadora. No entanto, a junção implante componente pode apresentar problemas, tais como a presença de um microgap entre essas partes constituintes. Assim, vários materiais tem sido testados na tentativa de obstruir esse espaço, com resultados controversos. O objetivo deste estudo foi avaliar in vitro o comportamento de um adesivo anaeróbico (Loctite® 510, Henkel Ltda) monocomponente, de alta resistência e inerte, na vedação do microgap impedindo a passagem bacteriana do meio externo para o interno do conjunto. Foram utilizados 90 implantes de conexão externa hexagonal (n = 30), conexão interna hexagonal (n = 30) e conexão interna cônica (n = 30), divididos em Grupo Controle (n = 45) e Grupo Teste (n = 45). Os implantes foram abertos em fluxo laminar e cada unidade recebeu 3l de BHI estéril internamente. Sobre cada unidade era parafusado um componente protético especifico para cada marca e com torques recomendados pelos fabricantes com torquímetro digital. Os conjuntos Teste receberam ainda uma fina camada de adesivo que era aplicada com microbrush entre as partes; e todas as unidades dos grupos Controle e Teste foram vedados com material obturador provisório na sua porção mais coronal. Cada conjunto foi então imerso em 75 l de Enterococcus faecalis (ATCC 29212) em minitubos até o limite entre a junção implante/componente protético. Todas as amostras foram incubadas em estufa bacteriológica por 7, 14 e 28 dias a 37oC antes de serem reabertas. Após o período proposto, o conteúdo interno dos implantes foi coletado com cones de papel estéreis, diluído e semeado em placas de Petri, incubadas por 48 horas. Houve diferença significante entre o grupo teste e controle no grupo de conexão externa hexagonal, em todos os tempos (Teste de Fischer e Qui-quadrado, p 0.05). O adesivo anaeróbico testado funciona como barreira, não permitindo a migração de bactérias para o meio interno do conjunto implante/componente protético. / The use of dental implants and prosthetic components have become very feasible resources to solve simple and complex cases in rehabilitation dentistry. However, the implant component junction may present problems, such as the presence of a microgap between these components parts.Therefore, several materials have been tested in an attempt to obstruct this space, with controversial results. The objective of this study was to evaluate in vitro the behavior of an anaerobic monocomponent adhesive (Loctite® 510, Henkel Ltda), high resistance and inert characteristics, in the microgap seal preventing bacterial passage from the external side to the inner side of the assembly. A total of 90 implants were used, with hexagonal external connection (n = 30), internal hexagonal connection (n = 30) and internal conical connection (n = 30) divided into Control Group (n = 45). Implants were opened in laminar flow cabinet and each unit received 3l of sterile BHI internally. On each unit a specific prosthetic component was screwed in for each brand and with torques recommended by the manufacturers with digital torque wrench. The sets of Test also received a thin layer of adhesive that was applied with microbrush between the parts; and all units of the Control and Test groups were sealed with provisional obturator material in their most coronal portion. Each set was immersed in 75 l of Enterococcus faecalis (ATCC - 29212) in mini-tubes to the limit between the implant / prosthetic component junction. All samples were incubated in a bacteriological incubator for 7, 14 and 28 days at 37oC before being reopened. After the proposed period, the internal contents of the implants were collected with sterile paper cones, diluted and seeded in Petri dishes, incubated for 48 hours. There was a significant difference between the test and control groups in the hexagonal external connection group at all times (Fischer and Chi-square test, p 0.05). The anaerobic adhesive tested works as a barrier, not allowing the migration of bacteria into the internal environment of the implant / prosthetic component assembly.
|
Page generated in 0.0708 seconds