• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1977
  • 27
  • 25
  • 25
  • 25
  • 14
  • 13
  • 12
  • 10
  • 6
  • 5
  • 4
  • 4
  • 1
  • Tagged with
  • 2028
  • 1276
  • 728
  • 391
  • 250
  • 178
  • 169
  • 166
  • 158
  • 148
  • 126
  • 119
  • 119
  • 113
  • 112
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Excreção urinária de albumina e pressão arterial nas 24 horas em pacientes com diabete melito tipo 2 normoalbuminúricos

Leitão, Cristiane Bauermann January 2005 (has links)
A nefropatia diabética (ND) é uma complicação freqüente do diabete melito (DM) e acarreta grande morbi-mortalidade. A prevenção desta complicação será mais efetiva se os indivíduos de maior risco, que se beneficiariam de tratamento intensivo dos fatores risco modificáveis, fossem precocemente identificados. A microalbuminúria, definida por valores de excreção urinária de albumina (EUA) de 20-199 g/min, ainda é o melhor marcador da instalação e progressão da ND, além de ser um fator de risco para o desenvolvimento de doenças macrovasculares. Estas associações podem ser explicadas pela teoria de que a microalbuminúria representa, na verdade, dano endotelial generalizado. A albuminúria nos limites superiores da normalidade também está associada ao desenvolvimento futuro de micro- e macroalbuminúria. Além disso, existe uma associação entre albuminúria normal-alta, doença cardiovascular e mortalidade geral em indivíduos com e sem DM. A EUA tem correlação direta e contínua com o desenvolvimento de doença renal e cardiovascular, sem um ponto determinado a partir do qual ocorreria um aumento mais importante do risco. No entanto, na prática clínica se faz necessário o estabelecimento de um valor crítico para guiar o tratamento dos pacientes. Algumas evidências apontam para valores de EUA em torno de 10 g/min como um novo ponto de corte para o diagnóstico de microalbuminúria.Concluindo, a associação entre a EUA e os desfechos renais e cardiovasculares parece ser contínua e já está presente até mesmo com níveis de EUA considerados normais. A adoção do valor de 10 g/min como de risco poderá identificar os pacientes que deveriam receber tratamento mais precoce e agressivo dos fatores de risco modificáveis.
32

Protocolo para monitorização residencial da pressão arterial : acurácia diagnóstica e correlação com marcadores prognósticos

Almeida, Antonio Eduardo Monteiro de January 2012 (has links)
Resumo não disponível
33

Avaliação da adesão à dieta DASH pelo escore DASH em paciente hipertensos : ensaio clínico randomizado

Santos, Luciana Kaercher John dos January 2017 (has links)
Novas formas terapêuticas e o progresso da medicina proporcionaram a emergência de infecções por Rhodotorula mucilaginosa em pacientes imunocomprometidos. Este estudo tem o objetivo de avaliar a suscetibilidade dos isolados de R. mucilaginosa aos antifúngicos convencionais, verificar a habilidade destes em modificar seu perfil de suscetibilidade após exposição a crescentes concentrações de anfotericina B (AMB) e comparar a atividade antifúngica de AMB ou voriconazol (VCR) em combinação com fármacos diversos frente aos dois grupos de R. mucilaginosa. Trinta e cinco isolados de R. mucilaginosa proveniente de pacientes foram estudados. Os isolados foram identificados baseado em métodos microbiológicos e moleculares. Definimos como grupo I os isolados fúngicos originais e grupo II como estes mesmos isolados após serem submetidos a crescentes concentrações de AMB. A exposição à AMB foi realizada segundo Fekete-Forgács et al., com algumas modificações. Os testes de susceptibilidade foram realizados de acordo com a técnica de microdiluição em caldo (CLSI M27-A3). AMB, caspofungina, fluconazol e VRC foram testadas isoladamente e ciprofloxacino, levofloxacino, anlodipino, ciclosporina A, fluoxetina, ibuprofeno, sinvastatina e varfarina foram testadas em combinação com AMB ou VRC, utilizando a técnica de microdiluição em caldo “checkerboard”. Os isolados do grupo I foram suscetíveis a baixas concentrações de AMB. A suscetibilidade ao VCR foi muito reduzida. Fluconazol e caspofungina não exibiram atividade frente a R. mucilaginosa. A exposição prolongada à AMB modificou a suscetibilidade dos isolados. Os testes de suscetibilidade com os isolados do grupo II mostraram elevadas Concentrações Inibitórias Mínimas (CIMs) para AMB e a inibição pelo VCR requisitou CIMs mais elevadas. No grupo I, a combinação de AMB + ibuprofeno mostrou o maior número de interações sinérgicas. No grupo II, a combinação com o maior número de interações sinérgicas foi AMB + sinvastatina. No grupo I, quando VCR foi combinado com levofloxacino, um potente sinergismo foi observado frente a isolados de R. mucilaginosa. No grupo II, combinação de VRC + ciclosporina A mostrou um potente sinergismo. Os tratamentos para infecção por R. mucilaginosa são restritos e a terapia combinada pode ser uma alternativa quando novos fármacos são combinados com aqueles já disponíveis no mercado. / New therapies and medical progress have led to emerging fungal infections by Rhodotorula mucilaginosa in immunocompromised patients. The objectives of this study were to evaluate the susceptibility profile of Rhodotorula mucilaginosa, verify the ability of this species to change its susceptibility profile after exposure to high concentrations of AMB, and compare the antifungal activity of AMB or voriconazole (VCR) plus combinations of non-antifungal medications against the two groups of R. mucilaginosa. Thirty-five strains of R. mucilaginosa isolated from patients were studied. The isolates were identified based on microbiological and molecular methods. We defined group I to be the original strains isolated from patients and group II as the same strains after in vitro exposure to AMB. AMB exposure was assayed according to Fekete-Forgács et al., with some modifications. Susceptibility tests were performed using the broth microdilution method (CLSI M27-A3). AMB, caspofungin, fluconazole (FLC), and VRC were tested alone and ciprofloxacin, levofloxacin, amlodipine, cyclosporine A, fluoxetine, ibuprofen, simvastatin, and warfarin were tested in combination with AMB or VRC, using the broth microdilution checkerboard technique. All group I isolates were susceptible to low concentrations of AMB. Susceptibility to VRC was quite poor. FLC and CAS exhibited no activity against R. mucilaginosa. Prolonged exposure to AMB changed the susceptibility of the isolates. The susceptibility tests with strains from group II showed high minimal inhibitory concentration (MICs) for AMB and the inhibition by VRC required more elevated MICs. In group I, the combination AMB + ibuprofen demonstrated the highest number of synergistic interactions. In group II, the most synergistic interactions was AMB + simvastatin. In group I, When VCR was combined with levofloxacin, a strong synergism was demonstrate against R. mucilaginosa isolates. In group II, VRC + cyclosporine A combination demonstrated a potent synergism. Treatments for R. mucilaginosa are restricted and a multidrug approach seems to be an alternative by administering novel chemical entity drugs with drugs currently on the market simultaneously.
34

Contribuição a calibração dinâmica de transdutores de pressão em altas pressões / Dynamic calibration of pressure transducers at high pressures / Contribution à l'etalonnage dynamque des capteurs de pression en hautes pressions

Leódido, Leonardo Moreira 15 December 2011 (has links)
Tese (doutorado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Mecânica, 2011. / Tese submetida ao Departamento de Engenharia Mecânica da Faculdade de Tecnologia da Universidade de Brasília como parte dos requisitos necessários para a obtenção do título de doutor em Ciências mecânicas e a Escola de Doutorado 432 SMI da Arts et Métiers ParisTech para obtenção do Título de Docteur Arts et Métiers. / Submitted by Tania Milca Carvalho Malheiros (tania@bce.unb.br) on 2013-05-08T15:03:46Z No. of bitstreams: 1 2011_LeonardoMoreiraLeódido_Parcial.pdf: 10241504 bytes, checksum: 6ad59b1bbf0f3b765f5d9ed78a01f758 (MD5) / Approved for entry into archive by Guimaraes Jacqueline(jacqueline.guimaraes@bce.unb.br) on 2013-05-16T14:15:02Z (GMT) No. of bitstreams: 1 2011_LeonardoMoreiraLeódido_Parcial.pdf: 10241504 bytes, checksum: 6ad59b1bbf0f3b765f5d9ed78a01f758 (MD5) / Made available in DSpace on 2013-05-16T14:15:02Z (GMT). No. of bitstreams: 1 2011_LeonardoMoreiraLeódido_Parcial.pdf: 10241504 bytes, checksum: 6ad59b1bbf0f3b765f5d9ed78a01f758 (MD5) / A variação dinâmica de grandezas físicas está presente na maior parte dos fenômenos físicos. Mas medir e avaliar esta variação não são tarefas simples, sendo necessário então, o desenvolvimento de sistemas de medição, que por sua vez devem ser caracterizados dinamicamente. Ou seja, é preciso submetê-los a um processo de calibração dinâmica, que consiste em determinar experimentalmente a função de transferência e as características dinâmicas do sistema. No domínio da pressão, a medição dinâmica vem sendo estudada desde a década de 60 de onde surgiram dispositivos e métodos capazes de fornecer os elementos necessários a um processo de calibração dinâmica e o estabelecimento de padrão primário em pressão dinâmica. Os trabalhos do Laboratório de Metrologia Dinâmica da Arts et Métiers ParisTech (LMD-ENSAM/Paris) e levaram ao desenvolvimento de um método de calibração e cálculo da incerteza para uma amplitude de pressão de 1 MPa. É nesse contexto que se insere esse trabalho, que tem como objetivo utilizar o mesmo método de calibração e cálculo de incerteza, utilizado em baixas, para altas pressões (> 1 MPa). Ou seja, desenvolver meios e/ou melhorias nos já existentes que visem reduzir as fontes de incerteza e permitir a aplicação do método sem alterá-lo. Para isso esse trabalho foi realizado no âmbito de um acordo de cooperação entre o LMD-ENSAM e o LMD-UnB. ______________________________________________________________________________ ABSTRACT / The dynamic change of physical quantities is present in most physical processes. But, measuring and evaluating this variation is not a simple task. This leads to the development of measurement systems, which be characterized dynamically. In other words, submit it to a dynamic calibration process (the experimental transfer function and the dynamic characteristics of the system). In the field of pressure, dynamic measurement has been studied since the 60's, enabling the development of devices and methods for a dynamic calibration and the establishment of primary standard in dynamic pressure. The works of the Laboratoire de Métrologie Dynamique of the Arts et Métiers ParisTech (LMD-ENSAM/Paris) led to the development of a method of calibration and uncertainty for a range of pressure of 1 MPa. This study aims to use the same method used in low pressure to high pressures (> 1 MPa), and develop the means or make upgrades in the devices to reduce the uncertainty and allow the application of the method without changing it. This work is part of a cooperation agreement between the LMD and LMD-ENSAM-UNB. ______________________________________________________________________________ RESUMÉ / La variation dynamique de grandeurs physiques est présente dans la plupart de phénomènes physiques. Mais, mesurer et évaluer ce changement n’est pas évident. Donc, il faut développer systèmes de mesure qui doivent être soumis à un étalonnage dynamique, c'est-à-dire déterminer sa fonction de transfert e ses caractéristiques dynamiques. Dans le domaine de la pression, l’étalonnage dynamique est étudié depuis les années 60, avec le développement de dispositifs, de méthodes et d’un, possible, étalon collectif. Les travaux do Laboratoire de Métrologie Dynamique des Arts et Métiers ParisTech (LMD-ENSAM/Paris) ont amené au développement d’une méthodologie d’étalonnage et de calcul de l’incertitude jusqu’à la pression de 1 MPa (10 bar). Donc, cette thèse a comme objectif utiliser cette même méthode en hautes pressions (> 1 MPa). C’est à dire, développer les moyens d’étalonnage et/ou faire des mises à jour aux méthodes déjà disponibles, de façon à réduire les sources d’incertitude. Cette thèse est faite dans le cadre de la coopération entre le LMD-ENSAM et le LMD-UnB.
35

Efeitos agudos do exercício resistido na pressão intra-ocular em homens ativos, jovens e saudáveis / Variações agudas da pressão intra-ocular durante o exercício resistido dinâmico em homens, jovens, ativos e saudáveis

Vieira, Geraldo Magela 03 June 2008 (has links)
Tese (doutorado)—Universidade de Brasília, Faculdade de Ciências da Saúde, 2008. / Submitted by Larissa Ferreira dos Angelos (ferreirangelos@gmail.com) on 2010-03-09T02:48:00Z No. of bitstreams: 1 2008_GeraldoMagelaVieira.pdf: 698788 bytes, checksum: 7fbcacb7f63e662f9de54bbfb8966c77 (MD5) / Approved for entry into archive by Daniel Ribeiro(daniel@bce.unb.br) on 2010-03-10T01:12:38Z (GMT) No. of bitstreams: 1 2008_GeraldoMagelaVieira.pdf: 698788 bytes, checksum: 7fbcacb7f63e662f9de54bbfb8966c77 (MD5) / Made available in DSpace on 2010-03-10T01:12:38Z (GMT). No. of bitstreams: 1 2008_GeraldoMagelaVieira.pdf: 698788 bytes, checksum: 7fbcacb7f63e662f9de54bbfb8966c77 (MD5) Previous issue date: 2008-06-03 / OBJETIVO: Verificar os do exercício resistido de supino reto horizontal sobre a pressão intra-ocular (PIO) executado com e sem bloqueio da respiração. MÉTODOS: Sessenta olhos de 30 indivíduos (todos homens) foram envolvidos. Os indivíduos executaram 4 repetições do exercício de supino, de dois modos diferentes. No modo I, eles deveriam prender a respiração durante a última repetição. No modo dois, eles deveriam soltar o ar normalmente durante a última repetição. A tonometria eletrônica (Tono-pen XL) foi utilizada para as medições da PIO. O olho direito foi usado para testar o modo I, e o esquerdo para o modo II. A PIO foi medida durante a quarta e última repetição, enquanto o indivíduo sustentava a barra de pesos na posição superior. RESULTADOS: A PIO média durante o exercício no modo I sofreu um aumento de 4,3 (SD 4,2) mmHg (p< 0.001, teste t pareado; variando de – 3,6 a + 17,7 mmHg). No modo II, a PIO média sofreu um aumento de 2,2 (SD 3,0) mmHg (p< 0.001, teste ANOVA, variando de -6,0 a + 8,7 mmHg). A PIO aumentou em 90% dos olhos submetidos ao exercício modo I e em 62 % no modo II. Um aumento na PIO > 5,0 mmHg foi observado em 9 olhos (30%) no modo I, e em 6 olhos no modo II (21%). A PIO em dois indivíduos que executaram o exercício modo I teve um aumento marcante (> 10.0 mmHg). CONCLUSÃO: A PIO aumenta de modo significativo durante o levantamento de peso no exercício de supino. Prender a respiração durante o exercício leva a um aumento extra da PIO. Os resultados podem são clinicamente significantes. _____________________________________________________________________________________ ABSTRACT / AIM: To evaluate the effect of resisted exercise bench press on intraocular pressure (IOP). METHODS: Sixty eyes of 30 normal, male subjects were enrolled. Subjects performed four repetitions of bench press exercise in two different ways: in mode I, breathing was held in the last repetition, and in mode II, subjects exhaled normally in the last repetition. An electronic tonometer (Ton-pen XL) was used for IOP measurements. The right eye was used for testing in mode I and the left eye for testing in mode II. IOP was measured during the fourth repetition in both modes while the subject sustained the exercise. RESULTS: mean IOP during exercise in mode I increased by 4.3 (SD 4.2) mmHg (p<0.001, ANOVA test; range -3.6 to +17.7 mmHg). In mode II, mean IOP increased by 2.2 (SD 3.0) mmHg (p< 0.001, paired t test; range -6.0 to + 8.7 mmHg). IOP increased in 90% of eyes submitted to mode I, and in 60% of eyes in mode II. An increase on IOP > 5.0 was observed in 9 eyes (30%) in mode I, and in six eyes (21%) in mode II. IOP in two eyes from subjects who performed exercise mode I was markedly increased (> 10.0 mmHg). CONCLUSION: IOP increases significantly during weight lifting in a bench press exercise. Holding the breath during the exercise leads to a further increase on IOP. The results are clinically significant.
36

Excreção urinária de albumina e pressão arterial nas 24 horas em pacientes com diabete melito tipo 2 normoalbuminúricos

Leitão, Cristiane Bauermann January 2005 (has links)
A nefropatia diabética (ND) é uma complicação freqüente do diabete melito (DM) e acarreta grande morbi-mortalidade. A prevenção desta complicação será mais efetiva se os indivíduos de maior risco, que se beneficiariam de tratamento intensivo dos fatores risco modificáveis, fossem precocemente identificados. A microalbuminúria, definida por valores de excreção urinária de albumina (EUA) de 20-199 g/min, ainda é o melhor marcador da instalação e progressão da ND, além de ser um fator de risco para o desenvolvimento de doenças macrovasculares. Estas associações podem ser explicadas pela teoria de que a microalbuminúria representa, na verdade, dano endotelial generalizado. A albuminúria nos limites superiores da normalidade também está associada ao desenvolvimento futuro de micro- e macroalbuminúria. Além disso, existe uma associação entre albuminúria normal-alta, doença cardiovascular e mortalidade geral em indivíduos com e sem DM. A EUA tem correlação direta e contínua com o desenvolvimento de doença renal e cardiovascular, sem um ponto determinado a partir do qual ocorreria um aumento mais importante do risco. No entanto, na prática clínica se faz necessário o estabelecimento de um valor crítico para guiar o tratamento dos pacientes. Algumas evidências apontam para valores de EUA em torno de 10 g/min como um novo ponto de corte para o diagnóstico de microalbuminúria.Concluindo, a associação entre a EUA e os desfechos renais e cardiovasculares parece ser contínua e já está presente até mesmo com níveis de EUA considerados normais. A adoção do valor de 10 g/min como de risco poderá identificar os pacientes que deveriam receber tratamento mais precoce e agressivo dos fatores de risco modificáveis.
37

Resposta autonômica durante imersão em indivíduos frequentadores e não frequentadores do meio líquido

Buss, Greiciane Jesus de Oliveira January 2005 (has links)
INTRODUÇÃO: Indivíduos saudáveis, quando expostos agudamente à imersão em água termoneutra, apresentam alterações no sistema de controle cardiovascular, com diminuição da atividade simpática e elevação da atividade vagal. Os efeitos crônicos da imersão em água termoneutra não são conhecidos. OBJETIVOS: Testar a hipótese de que a freqüente exposição à imersão em água termoneutra promove adaptações autonômicas. MÉTODOS: Participaram do estudo indivíduos freqüentadores (n= 14) e não freqüentadores do meio líquido (n=12). Foram registradas a pressão arterial e a freqüência cardíaca (FC) durante 15 minutos, estando o indivíduo inicialmente fora da água, em repouso, na posição supina e, em seguida, em ortostase. Imediatamente após, os indivíduos foram imersos em água termoneutra (32°C) até o terço médio do esterno, em posição ortostática. A variabilidade da freqüência cardíaca (VFC) foi determinada através de índices no domínio do tempo e da freqüência. RESULTADOS: A imersão em água termoneutra promoveu menor aumento do componente de alta freqüência da FC nos indivíduos freqüentadores do meio líquido (26,5 ± 7,8 un) do que nos não freqüentadores (40,1 ±12,3 un, p=0,012) . Houve uma tendência a menor redução do componente de baixa freqüência nos indivíduos freqüentadores (69,6 ± 7,3 un) do que nos indivíduos não freqüentadores (56,9 ± 12,4 un, com p= 0,069). CONCLUSÃO: Indivíduos freqüentemente expostos ao meio líquido apresentam menor modulação vagal e provável aumento da modulação simpática quando submetidos à imersão em água termoneutra. A exposição crônica ao meio líquido promove adaptações no sistema autonômico cardiovascular. / INTRODUCTION: During immersion in thermoneutral water, healthy individuals present a reduction in sympathetic nervous activity and reduction in vagal modulation to the heart. The chronic effects of the thermoneutral water immersion are unknown. OBJECTIVES: To test the hypothesis of that the frequent exposure to thermoneutral water immersion promotes autonomic adaptations. METHODS: In this study, we evaluated 14 healthy individuals who were frequently exposed and 12 healthy individuals who were not frequently exposed to water immersion. Subjects were maintained in the supine position, at rest out of the water, followed by the same period of time standing. They were then immersed in thermoneutral water (32°C) to the mild chest level, in the standing position for 15 minutes. Blood pressure, heart rate and time and frequency domain indices of heart rate variability were measured. RESULTS: Immersion in thermoneutral water resulted in significantly less increase in the high frequency component of the heart rate variability in individuals frequently exposed (26.5 ± 7.8 un) than individuals not frequently exposed to water immersion (40,1 ±12,3 un, p=0.012). There was a trend for less reduction in the low frequency component of heart rate variability in individuals frequently exposed (69.6 ±7,3 un) than individuals not frequently exposed to water immersion (56.9 ±12.4 un, p= 0.069). CONCLUSION: Individuals frequently exposed to water immersion present less vagal modulation and probably increased sympathetic modulation when immersed in thermoneutral water. Chronic exposure to the aquatic ambient promotes adaptations in the cardiovascular autonomic system.
38

Protocolo para monitorização residencial da pressão arterial : acurácia diagnóstica e correlação com marcadores prognósticos

Almeida, Antonio Eduardo Monteiro de January 2012 (has links)
Resumo não disponível
39

Condições maternas interferentes nas concentrações plasmaticas da gonadotrofina corionica e lactogenio placentario no primeiro trimestre de gravidez

Sollero, Celina de Paula Azevedo 06 December 1996 (has links)
Orientador: Jesse de Paula Neves Jorge / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-07-21T21:35:04Z (GMT). No. of bitstreams: 1 Sollero_CelinadePaulaAzevedo_D.pdf: 3949620 bytes, checksum: 6f7cdfc8912d5039d8dbe3c676068889 (MD5) Previous issue date: 1996 / Resumo: Partindo de estudos epidemiológicos que demonstraram haver associações entre baixo peso ao nascer, hipertrofia placentária e hipertensão arterial na vida adulta, nós estudamos um grupo de mulheres no primeiro trimestre da gestação, para verificar se existem indícios de interferências entre as condições maternas e a função placentária. Analisamos as relações entre o hormônio gonadotrófico coriônico e o hormônio lactogênio placentário e idade materna, paridade, índice de massa corpórea, pressão arterial, hemoglobina materna, hematócrito, volume corpuscular médio, contagem de glóbulos vermelhos, ferro, ferritina, capacidade total de ligação do ferro, 2,3-difosfoglicerato, carbóxihemoglobina, pressão parcial do oxigênio para a hemoglobina saturada em 50%, pressão parcial do hidrogênio, pressão parcial do oxigênio, pressão parcial do dióxido de carbono e saturação do oxigênio. Encontramos diferenças significativas entre fumantes e não fumantes com relação ao hormônio gonadotrófico coriônico, hematócrito, volume corpuscular médio, ferro e carbóxihemoglobina. Encontramos ainda correlações entre o hormônio gonadotrófico coriônico, e o índice de massa corpórea, a hemoglobina, o hematócrito e a carbóxihemoglobina, para o grupo total de gestantes. Entre as não fumantes o hormônio gonadotrófico coriônico se correlacionou negativamente com a pressão sistólica. O hormônio lactogênio placentário se correlacionou com a pressão sistólica. Entre as não fumantes o hormônio lactogênio placentário se correlacionou com a pressão parcial do oxigênio e a saturação do oxigênio. Concluímos que as condições maternas tem interferência na concentração plasmática dos hormônios placentários já no primeiro trimestre da gestação. / Abstract: Several studies have shown a relationship between low birth weight, large placental size and high blood pressure in adult life. Large placentas, were reported to be associated with maternal anaemia at the time of delivery. We studied a group of pregnant women during the first trimester of gestation, with the aim of investigating the influences of the maternal environment into the levels of placental hormones in maternal blood at this stage of pregnancy. We studied maternal blood levels of hCG and hPL and its relations to maternal age, parity, gestation age, maternal high and weight, Body Mass Index, blood pressure, Hb, Ht, MCV, RBCC, iron, ferritin, TIBC, 2,3-DPG, carboxi Hb, P50, PH, PC02, P02, 02sat and smoking habits. We found significant differences between smokers and non smokers in relation to hCG, Ht, MCV, Iron and carboxi Hb. We also found a relationship between hCG, and maternal weight, BMI, Hb, Ht, and carboxi Hb. Among the non smokers there was a significant negative correlation between the sistolic blood pressure and the levels of hCG. In hPL, there were significant correlation with maternal weight, BMI, and systolic blood pressure. Among the non smokers hPL correlated positively with P02 and 02sat. We concluded that maternal environment has influence in maternal blood levels of hCG and hPL in the early stages of pregnancy / Doutorado / Tocoginecologia / Doutor em Ciências Médicas
40

Subsidios ao estudo do efeito da concentração de solidos na perda de pressão e no rendimento de coleta de ciclones

Fassani, Fábio Luís, 1967- 03 March 1997 (has links)
Orientador: Leonardo Goldstein Junior / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-07-23T12:41:37Z (GMT). No. of bitstreams: 1 Fassani_FabioLuis_M.pdf: 4796890 bytes, checksum: c7409e7a6bb56260e87e590d164d2b29 (MD5) Previous issue date: 2018-07-23T09:41:25Z / Resumo: Nesta dissertação de mestrado,é estudado o efeito da concentração de sólidos na perda de pressão e no rendimento de coleta de ciclones. Para tanto, utiliza-se um dispositivo experimental constituído basicamente por um ciclone de 0,154 m de diâmetro, por um sistema de armazenamento e alimentação de partículas sólidas com ejetor, por um coletor de partículas coletadas pelo ciclone, por um filtro de mangas, e por dispositivos de medida de pressão, temperatura e vazão. São utilizadas partículas de FCC, um catalisador do processo de craqueamento do petróleo, e velocidades de entrada do gás entre 5 e 28 m/s. A concentração de sólidos atinge 20 kg de FCC/ kg de ar, valor bastante superior aos descritos pela literatura disponível. Considera-se também o efeito de uma válvula flap instalada na perna do ciclone. Os resultados mostram que a perda de pressão do escoamento com partículas é cerca de 47 por cento da perda de pressão do escoamento apenas de ar, na faixa de concentração estudada. Existe a tendência de aumento do rendimento de coleta com aumento da concentração de sólidos, até concentrações em tomo de 12 kg de FCC/ kg de ar. Acima dessa concentração o rendimento passa a diminuir. Nas condições. avaliadas, o rendimento de coleta foi maior na velocidade de 18 m/s do que na velocidade de 27 m/s. Os resultados indicam que deve existir um contrapeso ideal na válvula flap para otimizar o rendimento de coleta, em cada condição de concentração. Os métodos de previsão atualmente disponíveis não foram desenvolvidos para abranger as altas concentrações utilizadas neste trabalho, e não se mostraram adequados para estimar o rendimento de coleta / Abstract: In this thesis, the effect of solids loading on the cyclone pressure drop and overall collection efficiency was studied. The experimental setup was rnade up of a 0.154 m diameter cyclone, a solids storage and feeding system with an injector, a cyclone hopper, a bag filter, and pressure, temperature and flow measuring instruments. The solid particles used were FCC particles. Solids loading up to 20 kg DfFCC/ kg of air were used, with air inlet velocities between 5 and 28 m/s. The effect of a flap valve in the cyclone leg was also considered. The results showed that the cyclone pressure drop of the solids laden air flow was 47 per cent of the clean air flow, in the range of concentrations employed. There was a trend of increasing collection efficiency with increasing solids loading up to 12 kg of FCC/ kg of air. Above this loading, the collection efficiency decreased. At the conditions evaluated, the collection efficiency was higher at an inlet velocity of 18 m/s than it was at 27 m/s. The results indicated that it should exist an ideal flap valve counterweight that maximizes the collection efficiency in each loading condition. The available methods for estimating collection efficiency were not originally developed to cover the high solids loading used in the prestmt work, and were not able to predict the results in the range covered here / Mestrado / Termica e Fluidos / Mestre em Engenharia Mecânica

Page generated in 0.0345 seconds