• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 300
  • 46
  • 44
  • 44
  • 44
  • 30
  • 14
  • 14
  • 13
  • 13
  • 6
  • Tagged with
  • 309
  • 309
  • 309
  • 308
  • 108
  • 97
  • 97
  • 69
  • 58
  • 49
  • 44
  • 41
  • 39
  • 36
  • 36
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
271

Estratégias de computação paralela para a restauração de imagens com o funcional de regularização de Tikhonov / Parallel computing strategies for the restoration of functional images with the Tikhonov regularization

Dalmo Stutz 26 October 2009 (has links)
A Microscopia de Força Atômica é uma técnica que permite a aquisição de imagens em escalas nanométricas da superfície de quase todo tipo de material. Nessa escala, porém, as imagens podem apresentar uma relação sinal/ruído pobre, causado por efeitos degenerativos em sua qualidade. Para recuperar essas imagens ou minimizar os efeitos da degradação, técnicas de restauração de imagens são empregadas. Nas últimas décadas, diversas técnicas têm sido desenvolvidas e aplicadas com essa finalidade. Dentre elas, uma técnica de restauração, descrita aqui nesta tese, baseada na minimização de um funcional de Tikhonov com termos de regularização a um parâmetro, tem sido usada há alguns anos com resultados bastante satisfatórios no tratamento de imagens obtidas com o Microscópio de Força Atômica. O uso dessa técnica, entretanto, exige um grande esforço computacional que resulta em um tempo de execução elevado quando o programa que implementa o algoritmo de restauração é processado serialmente. Além disso, à medida que os equipamentos eletrônicos aumentam as suas capacidades, as imagens obtidas por esses equipamentos aumentam de resolução, assim como o esforço computacional e o tempo gasto para analisá-las e restaurálas. Assim, com o passar do tempo, o aumento da velocidade de processamento e do desempenho do programa de restauração tem-se tornado um problema cada vez mais crítico. Com o intuito de obter uma velocidade maior de processamento, nesta tese é descrita uma estratégia de implementação do algoritmo de restauração que faz uso de técnicas de computação paralela para se desenvolver uma nova versão paralela do programa de restauração. Os resultados obtidos com essa nova versão do programa mostram que a estratégia paralela adotada reduziu os tempos de execução e produziu bons desempenhos computacionais quando comparado com outras implementações feitas do mesmo algoritmo. Além disso, a nova estratégia apresenta níveis de desempenho maiores à medida que as resoluções das imagens restauradas aumentam, possibilitando a restauração de imagens maiores num tempo proporcionalmente mais curto.
272

Técnicas de processamento digital de imagens para análise de integridade do dossel - um modelo em mata semidecídua

Yamada, Thiago 28 February 2014 (has links)
Made available in DSpace on 2016-06-02T19:30:03Z (GMT). No. of bitstreams: 1 6171.pdf: 4392868 bytes, checksum: 676201b8bd1c6ecafe3c9456c172eb96 (MD5) Previous issue date: 2014-02-28 / Financiadora de Estudos e Projetos / The forests management and conservation are recently subjects discussed throughout the world, because they are directly correlation with the maintenance of environmental functions and services provided by natural environments. With growth of urban centers and extensive agriculture the natural areas have suffered and are suffering a big pressure making arise degraded areas constantly that encourage the recuperation movement in those areas. Moreover, the selective cut and the formation natural or artificial clearings make discontinuities in the canopy, irregularities reflected in the structure and profile. However, to realize the restoration and management, for example, a forest, first must to know your conservation state. This thesis intend to map more and less conserved areas through the analysis of structure and integrity in the canopy, realized with: canopy cover images, canopy closure images, vertical profile sketch, panchromatic image HRC of satellite CBERS-2B, and techniques digital image processing, beyond field survey. With intention to create a model able to identify, map, and monitor the forest degraded. / A conservação e manejo das florestas são temas muito atuais e discutidos em todo mundo, devido ao fato de estarem diretamente correlacionados com a manutenção das funções e serviços ambientais prestados pelos ambientes naturais. Com o crescimento dos centros urbanos e da agricultura extensiva, as áreas naturais sofreram e estão sofrendo uma grande pressão fazendo com que surjam constantemente áreas degradadas que acabam impulsionando o movimento de recuperação dessas áreas. Além disso, o corte seletivo e a formação de clareiras naturais ou artificiais produzem descontinuidades no dossel, refletindo em irregularidades na estrutura e no perfil. No entanto, para se realizar a recuperação e manejo, por exemplo, de uma floresta, deve-se primeiro conhecer seu estado de conservação. Esta tese pretende mapear áreas mais e menos conservadas, através da análise da estrutura e integridade do dossel, realizada com: imagens da cobertura do dossel, imagens da oclusão do dossel, desenho do perfil vertical, imagem pancromática HRC do satélite CBERS-2B e técnicas de processamento digital de imagens, além de levantamentos de campo. Com o intuito de criar um modelo capaz de identificar, mapear e monitorar a degradação de uma floresta.
273

Avaliação de exposição ocupacional em radiologia digital veterinária portátil

Drumond, Gisele Russo Canato 10 October 2012 (has links)
Este trabalho avalia a distribuição de dose recebida por trabalhadores envolvidos nos procedimentos de radiologia veterinária portátil digital e verifica a redução da dose obtida com a utilização de equipamentos de proteção individual. Para esta avaliação foram feitas medições utilizando dosímetros termoluminescentes tipo TLD-100, posicionados em sete diferentes pontos do corpo dos assistentes: mãos, tórax (por fora do avental), tireoide (por dentro do avental), cantos dos olhos esquerdo e direito e centro dos olhos e em cinco pontos diferente no médico veterinário: tórax (por fora do avental), tireoide (por dentro do avental), cantos dos olhos esquerdo e direito e centro dos olhos. As doses ocupacionais foram avaliadas em 63 procedimentos radiográficos de cães realizados com 49 assistentes e um médico veterinário na região metropolitana de Curitiba, PR. Os resultados mostram a importância do uso do protetor de tireoide e avental de chumbo para a redução da dose recebida pelos profissionais. As doses dos assistentes que seguraram os animais foram mais altas na região das mãos. Este estudo mostra a necessidade de medidas adicionais de proteção e a implementação de mecanismos de treinamento em proteção radiológica para os médicos e assistentes que trabalham com radiologia portátil digital. / This study evaluates the distribution of the dose received by work-people involved in portable digital veterinary radiology procedures and checks the dose reduction obtained with the use of individual protection equipments. For this evaluation measurements were made using TLD-100 thermoluminescent dosimeters,positioned at seven different spots on the body of the assistants: hands, chest (outside the apron), thyroid (inside the apron), left and right eye corners and at the forehead, and in five different spots in the veterinarian: chest (outside the apron), thyroid (inside the apron), left and right eye corners and the center of the eyes. The dosage was evaluated through the 63 procedures performed with 49 assistants and a veterinarian in the metropolitan region of Curitiba, PR. The results show the importance of using thyroid protection and lead aprons to reduce the dosage received by the veterinarian and assistants. The dosages of the assistants who held the animals were higher in the areas of the hands. This study shows the need for additional protective measurements and the implementation of training mechanisms in radiation protection for physicians and assistants who work with portable digital radiology.
274

Sistema de apoio na inspeção radiográfica computadorizada de juntas soldadas de tubulações de petróleo

Kroetz, Marcel Giovani 22 December 2012 (has links)
Petrobras / A inspeção radiográfica de juntas soldadas de tubulações é a atividade minuciosa e cuidadosa de observar imagens radiográficas de juntas soldadas em busca de pequenos defeitos e descontinuidades que possam comprometer a resistência mecânica dessas juntas. Como toda atividade que requer atenção constante, a inspeção radiográfica está sujeita a erros principalmente devido a fadiga visual e distrações naturais devido a repetitividade e monotonia inerentes à essa atividade. No presente trabalho, apresentam-se duas metodologias que têm por objetivo o auxílio e a automação da atividade de inspeção: a detecção automática dos cordões de solda nas radiografias e o realce das descontinuidades; compondo entre outras funcionalidades, um aplicativo completo de auxílio na inspeção radiográfica que agrega ainda a possibilidade de automação do processamento dessas imagens através da construção de rotinas e sua posterior aplicação a um conjunto de imagens semelhantes. Os resultados obtidos na detecção automática do cordão de solda são promissores, sendo possível, através da metodologia proposta, detectar cordões provenientes diferentes técnicas de ensaios radiográficos usuais. Quanto aos resultados do realce das descontinuidades, apesar de estes ainda não levarem a uma inspeção completamente autônoma e não supervisionada, apresentam resultados melhores do que aqueles existentes atualmente na literatura, principalmente quanto a correlação entre contraste visual do resultado do realce e a probabilidade de ocorrência de descontinuidades nas regiões demarcadas. Por fim, o realce das descontinuidades em conjunto com um aplicativo completo e iterativo contribui para uma maior leveza na atividade de inspeção, com o que se espera uma expressiva redução das taxas de erro devido à fadiga visual e um aumento considerável da produtividade através da automação das rotinas mais repetitivas de processamento digital a que as imagens radiográficas são submetidas durante sua inspeção. / The weld bead radiographic inspection is the activity of meticulously observe a radiographic image looking for small defects and discontinuities in the welded joints that can compromise the mechanical resistance of that joints. As any other activity than requires constant attention, the weld bead inspection is error prone due to visual fatigue, repetition and others distractions inherent to these activity. In this work, two new methodologies for help in the inspection activities are presented: the automatic detection of the weld bead and the highlighting of the weld bead discontinuities. Those that, among others functionalities, are included in a complete software solution for help in the weld bead inspection. Including the feature of macro programing for automation of the most common image processing routines and further processing bath of images in an automatic way. The results from the automatic weld bead detection is beyond the satisfactory, detecting weld bead from all the usual radiographic techniques. About the results of the highlight of the discontinuities, although that are not suited for a complete non supervised weld bead inspection, their correlation among intensity and the probability of the presence of a discontinuity is very well suited for discontinuities highlighting, a helpful tool in weld bead inspection. In conclusion, the proposed methodologies. combined with a fully featured interactive software solution, a lot contribute for the weld bead inspection activity, a decreased error rate due to visual fatigue and a better overall performance due to the automation of the most common procedures involved in this activity.
275

Métodos numéricos para o retoque digital /

Santos, Claudia Augusta dos. January 2005 (has links)
Orientador: Maurílio Boaventura / Banca: Antonio Castelo Filho / Banca: Heloisa Helena Marino Silva / Resumo: O objetivo deste trabalho þe aplicar Mþetodos Numþericos de ordem de precisão mais alta ao problema de Retoque Digital, visando melhorar a qualidade da aproximação quando comparada com o Método de Euler, que þe geralmente utilizado para esse tipo de problema. Para testar a eficiência de tais métodos, utilizamos três modelos de Retoque Digital: o modelo proposto por Bertalmþýo, Sapiro, Ballester e Caselles (BSBC), o modelo de Rudin, Osher e Fatemi conhecido como Variacional Total (TV) e o modelo de Chan e Shen, chamado de Difusão Guiada pela Curvatura (CDD). / Abstract: The purpose of this work is to apply Numerical Methods of higher order to the problem of Digital Inpainting, aiming to improve the quality of the approach when compared with the Euler’s Method which is generally used for this kind of problem. To test the e ciency of these methods we use three models of Digital Inpainting: the model considered by Bertalmþýo, Sapiro, Ballester and Caselles (BSBC), the model of Rudin, Osher and Fatemi known as Total Variation (TV) and the model of Chan and Shen, named Curvature Driven Di usion (CDD) / Mestre
276

Qualidade da imagem, limiar de contraste e dose glandular média em mamografia digital CR

Jakubiak, Rosangela Requi 30 January 2013 (has links)
Em muitos países, os sistemas de radiologia computadorizada (CR) representam a maioria dos equipamentos usados em mamografia digital. Este estudo apresenta um método para a otimização da qualidade da imagem e da dose em mamografia digital CR para pacientes com mamas de espessuras entre 45 e 75. As espessuras das mamas foram simuladas com placas de polimetilmetacrilato (PMMA). Técnicas de exposição otimizadas (tensão (kV), produto corrente-tempo (mAs) e combinação alvo/filtro) foram definidas como aquelas que fornecem uma razão contraste-ruído (CNR) ideal, denominada CNR alvo, que permite atingir o limiar de contraste das imagens do detalhe de diâmetro de 0,10 mm no simulador CDMAM (versão 3.4 Artinis Medical Systems, Netherlands) com um padrão de Dose Glandular Média (DGM) aceitável. Os resultados foram utilizados para os ajustes do Controle Automático de Exposição (CAE) pela equipe de manutenção. Um estudo retrospectivo de dois grupos de pacientes (Grupo 1-antes do ajuste do CAE e Grupo 2- após o ajuste do CAE) foi realizado. Os parâmetros de exposição foram reproduzidos nos simuladores para a determinação da CNR, da DGM e do limiar de contraste. As imagens clínicas destes pacientes foram analisadas por três radiologistas especialistas em mamografia que responderam questões sobre as estruturas anatômicas, ruído e contraste em áreas de valores de pixels altos ou baixos, sobre nitidez e contraste da imagem. Os resultados mostram que o método proposto foi efetivo para todas as espessuras de mama avaliadas. O ajuste do CAE proporcionou a concentração de valores da CNR no Grupo 2 mais próximas ao CNR alvo e que, mesmo como aumento do nível de ruído nas imagens clínicas, as análises do CDMAM mostraram que não houve prejuízo na identificação do objeto de 0,10 mm de diâmetro. Finalmente, este estudo conclui que o uso dos CAE das unidades de raios X baseados em fornecer uma dose constante ao detector pode ocasionar algumas dificuldades para alguns sistemas CR operarem nas condições ótimas. / In many countries, computed radiography (CR) systems represent the majority of equipments used in digital mammography. This study presents a method for optimizing image quality and dose in CR mammography of patients with breast thicknesses between 45 to 75mm. The breast thicknesses were simulated with polymethylmetacrylate (PMMA). Optimazed exposure parameters ((voltage (kV), mA and time product (mAs) and target/filter combination)) was defined as giving an ideal contrast to noise ratio (CNR), defined as target CNR, to reach the threshold contrast of CDMAM (version 3.4) phantom (Artinis Medical Systems, Netherlands) images for acceptable mean glandular dose (MGD). These results were used for adjustments in the automatic exposure control (AEC) by the maintenance team. A retrospective study of two groups of patients (Group 1-before AEC adjustment and Group 2- after AEC adjustment) were done. The exposure parameters were reproduced in the phantoms to determine of CNR, MGD and threshold contrast. The clinical images of these patients were analyzed by three experienced radiologists who answered questions about anatomical structures, noise and contrast in low and high pixel value areas and image sharpness and contrast. The results showed that the proposed method was effective for all breast thickness evaluated. The AEC adjustment showed a concentration of CNR in Group 2 nearer of target CNR, and that the increasing of noise in clinical images, the CDMAM analysis showed that this level of noise did not disturb the detail of 0,1 mm diameter. Finally, this study also concluded that the use AEC of X rays unit based on constant dose to the detector may bring some difficulties to CR systems operate in optimal conditions.
277

Fusão de modelos 3D com imagens térmicas para aplicações médicas

Krefer, Andriy Guilherme 26 June 2015 (has links)
CNPq; CAPES / A termografia permite a visualização de valores de temperatura de um corpo por meio de imagens. Na área médica, encontra aplicações em oncologia, análise de queimaduras, doenças vasculares, doenças respiratórias, doenças de pele e como forma geral de verificação da vitalidade dos tecidos. A termografia 3D consiste de uma malha 3D com uma textura térmica projetada em sua superfície, oferecendo uma visualização mais precisa dos padrões de temperatura das estruturas anatômicas. Propõe-se, por meio do presente trabalho, um sistema capaz de combinar imagens termográficas 2D com sua malha 3D correspondente e, como resultado, entregar uma imagem termográfica 3D para aplicações médicas. Para isso foram utilizadas as técnicas de Otimização por Enxame de Partículas (PSO) e de reconstrução 3D Structure from Motion (SfM). Diferentemente de outros trabalhos na literatura, a malha 3D e as imagens térmicas não precisam ser adquiridas simultaneamente, não sendo necessário um arranjo mecânico dedicado. A malha 3D pode ter origem em um scanner 3D ou em uma imagem de ressonância magnética, por exemplo. Para avaliar os resultados, um phantom, isto é, um objeto estático de avaliação, com propriedades conhecidas, foi construído. Para tal, uma técnica inédita, utilizando placas de circuito impresso foi desenvolvida. Como resultado, comparações entre a saída do método proposto e o phantom, apresentaram um erro máximo de 3,73 mm e médio de 1,41 mm, com desvio padrão de 0,74 mm, em um phantom de 100 x 150 x 103,2 mm. / Thermography is an imaging method that allows temperature visualization of various regions of an object. In medicine, it finds applications related to oncology, burn trauma, vascular, respiratory and skin diseases, and as a general tissue vitality checking tool. 3D thermography adds tridimensional information to the conventional 2D thermography. It is made from a 3D mesh wrapped by thermal texture, enabling a more precise visualization of thermal patterns of anatomical structures. We propose a system capable of combining 2D thermal images with their corresponding 3D mesh, delivering a 3D thermogram for medical applications as a result. We used Particle Swarm Optimization (PSO) for mesh alignment and Structure from Motion (SfM) for 3D reconstruction in the present method. In contrast to most research found in the literature, the 3D mesh and the thermal images do not need to be acquired simultaneously, and a mechanical support for the thermal camera and the 3D scanner is not required. The 3D mesh may be acquired, for instance, from a 3D scanner or a magnetic resonance imaging machine. In order to evaluate the results, a phantom, that is, a static assessment object of known properties has been built. For this purpose, a novel technique using printed circuit boards has been developed. As a result, comparison between the output of the method and the phantom shows a maximum error of 3.73 mm and a mean error of 1.41 mm with 0.74 mm of standard deviation in phantom of 100 x 150 x 103.2 mm. / 5000
278

Metodologia para análise na perícia criminal de microvestígios forenses: fios de cabelo / Method for criminal exam analysis in forensic trace: hair

Lara, Alexandre Guilherme de 19 March 2016 (has links)
A presente dissertação expositiva teve por objetivo o desenvolvimento de metodologia para análise forense de fios de cabelos. Considerado um microvestígio comum de ser encontrado em locais de crime contra pessoa (DOREA, 2010), fios de cabelo são capazes de fornecer informações úteis na identificação da autoria do crime, ou a entender a dinâmica de um crime violento (ROBERTSON, 1999). As fibras compostas por fio de cabelo deterioram-se lentamente (ROBBINS, 2012), e podem ser analisadas mesmo transcorrido longo período de tempo, tornando-se ainda mais relevante em locais de crime que são examinados tardiamente. Os equipamentos utilizados no presente estudo são de uso comum em laboratórios, permitindo que a metodologia seja amplamente empregada. O presente estudo buscou desenvolver metodologias para análise por microscopia ótica de fios de cabelo, identificando as características de interesse forense passíveis de serem estudadas. Utilizaram-se amostras de fios de cabelo para análise das seções transversais e longitudinais, de forma destrutiva e não destrutiva, com preparação de lâminas de forma permanente e não permanente. Como resultado obteve-se uma metodologia de baixo custo descrita para aplicações forenses em vestígios coletados em locais de crime, em armas de crimes ou em suspeitos, de forma a combater a criminalidade face o poder probatório da prova material. Constatou-se a possibilidade de identificação de características macroscópicas e microscópicas de fios de cabelo, que revelam atributos do doador e, em alguns casos, auxiliar no entendimento da dinâmica do crime. A agilidade observada no método permite ainda a obtenção de informações durante a fase preliminar ou de investigação em curtos espaços de tempo. / This monographic dissertation aimed to develop standards of microscopic forensic hair analysis. A very common trace to be found in certain crimes (DOREA, 2010), hair can be helpful to provide information regarding the perpetrator or the way that the crime was committed (ROBERTSON, 1999). Once hair is a low degradation fiber (ROBBINS, 2012), it can be analyzed long after the fact, becoming even more relevant in crime scenes processed after elapse time. The equipment’s used for this study are commonly found in forensic labs, allowing broad use. The study was restricted to literature review and further elaboration of preparation and analysis by optical microscopy of hairs methods, identifying the characteristics of forensic interest that can be studied. Samples of hair for cross section and longitudinal sections analysis had been used. Destructive and non-destructive methods in permanent and non-permanent blades where tested. As a result a low cost methodology was obtained for forensic applications in traces collected from crime scenes, weapons used in crimes or suspects, in order to combat crime by using the probative power of physical evidence.
279

Desenvolvimento de software e hardware para diagnóstico e acompanhamento de lesões dermatológicas suspeitas para câncer de pele

Oselame, Gleidson Brandão 28 August 2014 (has links)
O câncer é responsável por cerca de 7 milhões de óbitos anuais em todo o mundo. Estima-se que 25% de todos os cânceres são de pele, sendo no Brasil o tipo mais incidente em todas as regiões geográficas. Entre eles, o tipo melanoma, responsável por 4% dos cânceres de pele, cuja incidência dobrou mundialmente nos últimos dez anos. Entre os métodos diagnósticos empregados, cita-se a regra ABCD, que leva em consideração assimetria (A), bordas (B), cor (C) e diâmetro (D) de manchas ou nevos. O processamento digital de imagens tem mostrado um bom potencial para auxiliar no diagnóstico precoce de melanomas. Neste sentido, o objetivo do presente estudo foi desenvolver um software, na plataforma MATLAB®, associado a um hardware para padronizar a aquisição de imagens, visando realizar o diagnóstico e acompanhamento de lesões cutâneas suspeitas de malignidade (melanoma). Utilizou-se como norteador a regra ABCD para o desenvolvimento de métodos de análise computacional. Empregou-se o MATLAB como ambiente de programação para o desenvolvimento de um software para o processamento digital de imagens. As imagens utilizadas foram adquiridas de dois bancos de imagens de acesso livre. Foram inclusas imagens de melanomas (n=15) e imagens nevos (não câncer) (n=15). Utilizaram-se imagens no canal de cor RGB, as quais foram convertidas para escala de cinza, aplicação de filtro de mediana 8x8 e técnica de aproximação por vizinhança 3x3. Após, procedeu-se a binarização e inversão de preto e branco para posterior extração das características do contorno da lesão. Para a aquisição padronizada de imagens foi desenvolvido um protótipo de hardware, o qual não foi empregado neste estudo (que utilizou imagens com diagnóstico fechado, de bancos de imagem), mas foi validado para a avaliação do diâmetro das lesões (D). Utilizou-se a estatística descritiva onde os grupos foram submetidos ao teste não paramétrico para duas amostras independentes de Mann-Whitney U. Ainda, para avaliar a sensibilidade (SE) e especificidade (SP) de cada variável, empregou-se a curva ROC. O classificador utilizado foi uma rede neural artificial de base radial, obtendo acerto diagnóstico para as imagens melanomas de 100% e para imagens não câncer de 90,9%. Desta forma, o acerto global para predição diagnóstica foi de 95,5%. Em relação a SE e SP do método proposto, obteve uma área sob a curva ROC de 0,967, o que sugere uma excelente capacidade de predição diagnóstica, sobretudo, com baixo custo de utilização, visto que o software pode ser executado na grande maioria dos sistemas operacionais hoje utilizados. / Cancer is responsible for about 7 million deaths annually worldwide. It is estimated that 25% of all cancers are skin, and in Brazil the most frequent in all geographic regions type. Among them, the melanoma type, accounting for 4% of skin cancers, whose incidence has doubled worldwide in the past decade. Among the diagnostic methods employed, it is cited ABCD rule which considers asymmetry (A), edges (B), color (C) and diameter (D) stains or nevi. The digital image processing has shown good potential to aid in early diagnosis of melanoma. In this sense, the objective of this study was to develop software in MATLAB® platform, associated with hardware to standardize image acquisition aiming at performing the diagnosis and monitoring of suspected malignancy (melanoma) skin lesions. Was used as the ABCD rule for guiding the development of methods of computational analysis. We used MATLAB as a programming environment for the development of software for digital image processing. The images used were acquired two banks pictures free access. Images of melanomas (n = 15) and pictures nevi (not cancer) (n = 15) were included. We used the image in RGB color channel, which were converted to grayscale, application of 8x8 median filter and approximation technique for 3x3 neighborhood. After we preceded binarization and reversing black and white for subsequent feature extraction contours of the lesion. For the standardized image acquisition was developed a prototype hardware, which was not used in this study (that used with enclosed diagnostic images of image banks), but has been validated for evaluation of lesion diameter (D). We used descriptive statistics where the groups were subjected to non-parametric test for two independent samples Mann-Whitney U test yet, to evaluate the sensitivity (SE) and specificity (SP) of each variable, we used the ROC curve. The classifier used was an artificial neural network with radial basis function, obtaining diagnostic accuracy for melanoma images and 100% for images not cancer of 90.9%. Thus, the overall diagnostic accuracy for prediction was 95.5%. Regarding the SE and SP of the proposed method, obtained an area under the ROC curve of 0.967, which suggests an excellent diagnostic ability to predict, especially with low costs, since the software can be run in most systems operational use today.
280

Desenvolvimento de ferramenta computacional para metrologia com microtomografia computadorizada / Development of computational tool for metrology with computed microtomography

Júlio Cesar Corrêa de Oliveira 04 May 2015 (has links)
Esta tese apresentada uma proposta de desenvolvimento de uma ferramenta computacional para metrologia com microtomografia computadorizada que possa ser implantada em sistemas de microtomógrafos convencionais. O estudo concentra-se nas diferentes técnicas de detecção de borda utilizadas em processamento de imagens digitais.Para compreender a viabilidade do desenvolvimento da ferramenta optou-se por utilizar o Matlab 2010a. A ferramenta computacional proposta é capaz de medir objetos circulares e retangulares. As medidas podem ser horizontais ou circulares, podendo ser realizada várias medidas de uma mesma imagem, uma medida de várias imagens ou várias medidas de várias imagens. As técnicas processamento de imagens digitais implementadas são a limiarização global com escolha do threshold manualmente baseado no histograma da imagem ou automaticamente pelo método de Otsu, os filtros de passa-alta no domínio do espaço Sobel, Prewitt, Roberts, LoG e Canny e medida entre os picos mais externos da 1 e 2 derivada da imagem. Os resultados foram validados através de comparação com os resultados de teste realizados pelo Laboratório de Ensaios Mecânicos e Metrologia (LEMec) do Intstituto Politécnico do Rio de Janeiro (IPRJ), Universidade do Estado do Rio de Janeiro (UERJ), Nova Friburdo- RJ e pelo Serviço Nacional da Indústria Nova Friburgo (SENAI/NF). Os resultados obtidos pela ferramenta computacional foram equivalentes aos obtidos com os instrumentos de medição utilizados, demonstrando à viabilidade de utilização da ferramenta computacional a metrologia. / This thesis presents a proposal to develop a computational tool for metrology using computed microtomography (microCT) systems that can be implemented in conventional microCT systems.This study focuses on the different techniques used for edge detection in image processing.To test the feasibility of developing the tool we chose to use the Matlab 2010a. The proposed computational tool is capable of measuring circular and rectangular objects.The measures can be horizontal or circular and can be performed several measurements of the same image, a measure of multiple images or more measures of multiple images.The techniques implemented of processing digital images are global thresholding with choice of threshold manually based on the image histogram or automatically by the Otsu method, the high-pass filter in the space domain Sobel, Prewitt, Roberts, LoG and Canny and the distance between the outermost "peaks" of the 1st and 2nd derivative image.The results were validated by comparison with test results performed by the Mechanical Testing Laboratory and Metrology (LEMec) Polytechnic Intstituto of Rio de Janeiro (IPRJ), State University of Rio de Janeiro (UERJ), Nova Friburdo- RJ and the National Industry Service - Nova Friburgo (SENAI / NF).The results obtained by computational tool were equivalent to those obtained with the measuring instruments used, demonstrating the feasibility of using of computational tool for metrology.

Page generated in 0.1072 seconds