• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 3
  • Tagged with
  • 6
  • 6
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Aspect évolutif des cicatrices hépatiques de radiofréquence et de cryothérapie en échographie de contraste

Bertin, Caroline. Lucidarme, Olivier January 2008 (has links) (PDF)
Thèse d'exercice : Médecine. Imagerie médicale-Radiodiagnostic : Paris 12 : 2007. / Titre provenant de l'écran-titre. 60 f. : ill. Bibliogr. f. 58-60.
2

Développement de nouveaux agents de contraste pour l'IRM à base de β- et α-cyclodextrines régio-fonctionnalisées par des ligands pyridino-carboxylate et -phosphonate. / Development of new MRI contrast agents based on β- and α-cyclodextrins, regio-functionalized with pyridine-carboxylate and pyridyne-phosphonate ligands

Sappei, Celia 25 May 2018 (has links)
L’Imagerie par Résonance Magnétique est une technique d’imagerie possédant une des plus hautes résolutions d’images, utilisée pour le diagnostic clinique et en recherche. Cependant cette technique souffre d’une faible sensibilité intrinsèque due au faible contraste naturel entre les différents tissus. Pour pallier à cette limitation, des agents de contraste, principalement des complexes de Gd(III), sont actuellement utilisés et continus d’être développés. Ce projet de thèse s’inscrit dans la volonté de concevoir de nouveaux agents de contrastes plus efficaces et plus stables en utilisant la β- et l’α-cyclodextrines (CD) comme plateforme capables d’intégrer trois ou quatre fonctions pyridine-carboxylates ou pyridine-phosphonates, connues pour leur pouvoir chélatant du Gd(III). La première partie des travaux concerne les aménagements fonctionnels des CDs afin de pouvoir les fonctionnaliser régiosélectivement avec des bras chélatants du Gd(III) de types pyridino-carboxylate et pyridino-phosphonate. La deuxième partie traite de la caractérisation physico-chimique des nouveaux systèmes complexes Gd-ligands synthétisés (Gd-Lα et Gd-Lβ). Les principales propriétés caractérisant les agents de contraste ont été mesurées. Ainsi, de très bonne relaxivités ont été obtenue (25 mM-1s-1 < r1 < 40 mM-1s-1). Cependant, les stabilités des complexes se sont avérées faibles (4,24 < log KGdL < 5,58). En perspectives, il est nécessaire d’obtenir un juste équilibre entre une forte relaxivité et une stabilité élevée pour assurer la non-libération du Gd(III) toxique. / Magnetic Resonance Imaging is one of the most important and non-invasive tools for clinical diagnostics and biomedical researches. Nevertheless, this modality suffers from intrinsic low sensitivity. To overcome this limitation, contrast agents, mostly based on polyaminocarboxylate complexes of gadolinium are used. The aim of this project was to design new Gd(III)-based contrast agents using β- and α-cyclodextrins (CD), known to generate high relaxivity, functionalized with pyridine-carboxylate and pyridine-phosphonate ligands, known for their good affinity with the lanthanide cations. Here we first investigated the regio-functionalization of the β-CD on the primary face to access to scaffold called Lβ with four pyridine-carboxylate ligands. To develop an efficient and reproducible synthesis, HPLC analysis was implemented. Then, using these conditions, carboxylate- and phosphonate-ester, precursors to access α-CD ligands Lα and Lα’, were synthesized. The carboxylate-ester deprotection step successfully afforded the ligand noted Lα contrary to the deprotection of phosphonate ester which still have to be explored. Characterizations of these complicated Gd-ligands systems (Gd-Lα et Gd-Lβ) were reported. Their stability and relaxivity were measured and very good relaxivities were obtained (25 mM-1s-1 < r1 < 40 mM-1s-1). These new structures open the way to an improvement in term of stability.
3

Liver-specific contrast media for MRI and CT experimental studies

Leander, Peter. January 1995 (has links)
Thesis (doctoral)--Lund University, 1995.
4

Stealth nanoparticles for preclinical X-rays imaging and multimodal X-rays/MRI (magnetic resonance imaging) imaging / Nanoparticules furtives pour l'imagerie préclinique à rayons X et multimodale rayons-X/IRM (imagerie à résonance magnétique)

Wallyn, Justine 11 December 2017 (has links)
L’imagerie biomédicale est aujourd’hui un outil essentiel pour établir un diagnostic grâce à l’observation des tissus et des fluides biologiques. L’usage d’instruments à imagerie combinée avec des produits de contraste est la clé pour réussir à distinguer précisément un tissu ciblé via l’accumulation de produit de contraste dans le tissu. Les deux principaux appareils à imagerie utilisés sont le scanner à rayons X et l’imagerie à résonance magnétique (IRM). Ils sont fréquemment employés en complément de l’un et l’autre. Typiquement, de petites molécules iodées hydrophiles sont utilisées comme produit de contraste pour la radiographie à rayons X tandis que l’IRM implique des matériaux magnétiques tels que des nanoparticules d’oxyde de fer. Dans le cadre de ce projet doctoral, nous avons donc proposé deux nouveaux produits de contraste dont le premier visait à constituer une alternative aux produits iodés dont la rapide élimination et la toxicité rénale forment deux problèmes récurrents et un second produit, cette fois-ci bimodale, afin de faciliter les procédures d’imagerie bimodale. Pour le premier point, des nanoparticules de polymères iodés pour l’imagerie à rayons X ont été formulées et ce, par une technique de nanoprécipitation. Les paramètres de formulation ont été élucidés de telle sorte que les nanoparticules possédaient une distribution de taille adaptée pour l’administration par voie intraveineuse et une teneur en iode suffisante en iode pour contraster sous rayons X. Une étude in vivo a révélé le potentiel du produit de contraste à visualiser distinctement le foie et la rate et ce, tout en ne présentant pas les principaux problèmes des produits iodés commerciaux. La seconde étude a eu pour but de formuler des nano-véhicules lipidiques capables de générer un contraste pour l’imagerie à rayons X et l’IRM de par l’incorporation d’huile iodée et de nanoparticules d’oxyde de fer dans le coeur de nano-émulsions. Ceci avait pour objectif de fournir une plateforme nanoparticulaire bimodale pour réaliser efficacement et rapidement des procédures d’imagerie multimodale. Nous avons réussi à produire un efficace agent de contraste bimodal permettant d’observer distinctement le foie et les reins par IRM et le foie et la rate par imagerie à rayons X. La pharmacocinétique de la substance administrée a ainsi pu être mise en avant grâce à la bimodalité de l’agent. Employer l’IRM a permis de montrer qu’une fraction de la dose injectée était éliminée par voie rénale tandis que l’imagerie à rayons X a confirmé que les deux tissus, foie et rate,étaient passivement ciblés par l’agent de contraste. Ces deux études ont donc fournies de potentielles solutions pour répondre aux besoins en produits pour l’imagerie à rayons X et en formulations facilitant l’imagerie bimodale des tissus mous. / Biomedical imaging is nowadays an essential tool to establish a diagnosis by means of observation of tissues and biological fluids. Combination of imaging instrument with contrast enhancers is a key to obtain clear delineation of a desired tissue by accumulation of a contrast agent into this specific target. The two main imagers are the X-ray scanner and the magnetic resonance imaging (MRI).These imagers are frequently used in conjuncture. Typically, small hydrosoluble iodinated molecules are used as contrasting material for radiography whereas MRI involves magnetic materials like iron oxide nanoparticles. In this work, we proposed two novel contrast agents, the first one was aiming to form an alternative to iodinated contrast agents suffering from fast excretion and causing renal toxicity whereas the second one was aiming at providing bimodal contrasting ability to facilitate access to bimodal imaging procedure in clinics. In the first case, iodinated polymeric nanoparticles, serving for preclinical X-ray imaging were formulated by nanoprecipitation technique. Parameters of formulation were elucidated to provide nanoparticles with size distribution suitable for in vivo administration and high iodine content for contrast enhancement. In vivo study revealed the efficacy of our nanoparticles to clearly visualize liver and spleen and limiting current issues associated with marketed radiopaque contrast agents. The second work achieved was aiming at formulating bimodal lipids-based nanocarriers capable of yielding contrast enhancement for X-ray imaging and MRI by combining iodinated oil and iron oxide nanoparticles within a nano-emulsion core. This would provide bimodal nanoparticulate platform to carry out fast and efficient dual modal imaging procedures. In this context we succeeded to generate efficient dual modal contrast agent yielding clear visualization of liver and kidney by MRI and liver and spleen by X-ray imaging. Pharmacokinetic profile was so determined thanks to bimodal imaging. Using MRI allowed to show that kidneys eliminated a fraction of the dose whereas X-ray imaging confirmed that both tissues, liver and spleen, were passively targeted. These two studies proposed solutions limiting current issues of radiopaque contrast agents and novel formulations to facilitate bimodal imaging for soft tissues imaging.
5

Formulation de nano-particules iodées comme agents de contraste a longue rémanence vasculaire pour tomodensitométrie / Formulation of iodinated nano-particles as micro-CT blood pool contrast media

Hallouard, François 12 December 2012 (has links)
L’objectif de cette thèse est de réaliser un agent de contraste vasculaire pour tomodensitométrie utilisable en préclinique. En collaboration avec le laboratoire de biogalénique de Strasbourg, ce travail a permis d’obtenir des nano-émulsions iodées produites par diffusion spontanée de surfactif et des nanoparticules iodées produites par ”émulsion - diffusion de solvant”, comme agent de contraste vasculaire. Ces émulsions et particules polymériques présentent en effet, un temps de rémanence vasculaire de plusieurs heures, un pouvoir contrastant suffisant pour un usage en tomodensitométrie (compris entre 170 et 400 HU), la possibilité de les administrer par intraveineuse et une stabilité de plusieurs mois. Les nano-émulsions, notamment celles produites à partir de Lipiodol®, sont les plus prometteuses comme agents de contraste vasculaire de par leur forte radiopacité (475 ± 30 HU) et leur rémanence vasculaire (T1/2 of 4.1 ± 1.10 h). Les nanoparticules iodées à base de PCL présentent un pouvoir contrastant inférieur (168 ± 13 HU) mais elles sont connus pour leur capacité à modifier la libération du principe actif encapsulé. De ce fait même si les agents de contraste de nature lipidique ou ceux inorganiques sont plus performant, elles restent intéressantes pour une visualisation rapide de la distribution du principe actif dans l’organisme. Cette thèse par ailleurs, apporte plusieurs éléments pour la compréhension de la formulation des nano-émulsions obtenues par diffusion spontanée de surfactif et celle des nanoparticules produites par ”émulsion - diffusion de solvant”. Concernant les nano-émulsions, l’influence de l’iodation des huiles et du surfactif a été étudiée autant sur le plan pharmacotechnique que ceux toxicologique et pharmacocinétique. Concernant les nanoparticules à base de PCL, nous avons montré que l’impact du type d’huile et de l’iodation, des polymères PCL et PCL-mPEG et de diverses méthodes de concentration sur la formulation / The aim of this thesis is to formulate a blood pool contrast agent for preclinical X-ray imaging application. In collaboration with the galenic laboratory of Strasbourg, this work has allowed to obtain iodinated nano-emulsions produced by spontaneous diffusion of surfactant and nano-particles produced by iodine ”emulsion - solvent diffusion” as blood pool contrast agent. These emulsions and polymer particles present indeed a vascular persistence of several hours, a sufficient contrast to be use in computed tomography (between 170 and 400 HU), the ability to be administered intravenous and stability of several months. Nano-emulsions, including those produced from Lipiodol®, are the most promising as blood pool contrast media by their high radiopacity (475 ± 30 HU) and vascular persistence (T1/2 of 4.1 ± 1.10 h). Iodinated nano-particles of PCL have a lower X-ray attenuation (168 ± 13 HU), but they are known for their control release of the encapsulated substances. Therefore even if inorganic or lipidic contrast agents show a better contrast, they remain attractive for rapid visualization of the co-encapsulated substance distribution in the body. This thesis also introduced several features for understanding the formulation of nano-emulsions obtained by spontaneous diffusion of surfactant and the nano-particles produced by ”emulsion - solvent diffusion.”
6

Algorithms for the analysis of 3D magnetic resonance angiography images

Tizon, Xavier 15 October 2004 (has links) (PDF)
L'athérosclérose est une atteinte de la paroi des vaisseaux, qui détériore progressivement la circulation du sang à mesure qu'elle évolue. Les crises cardiaques et les attaques cérébrales qui sont les conséquences de cette maladie causent, dans les pays industrialisés, plus de décès que le cancer. L'angiographie est l'ensemble des techniques d'imagerie utilisées durant le diagnostic, le traitement, et le suivi de l'athérosclérose. Récemment, il a été montré que l'angiographie par Résonance Magnétique (ARM) avait un fort potentiel pour remplacer l'angiographie conventionnelle, invasive, par imagerie à rayons X. Cependant, pour exploiter toutes les informations apportées par cette modalité, il est nécessaire de mettre au point des méthodes plus objectives et plus reproductibles.<br />Cette thèse montre, à l'aide de deux applications, comment l'analyse d'images peut proposer une solution pour la définition et l'implémentation de ces méthodes. Premièrement, en utilisant la segmentation pour améliorer la visualisation de clichés d'ARM utilisant des produits de contraste du pool sanguin. Cette technique est aussi appliquée en angiographie scanner. Nous montrons que, en utilisant un algorithme issu de la théorie des graphes et de la logique floue, associé à une interaction limitée avec un utilisateur expert, nous pouvons simplifier la visualisation de structures 3D complexes comme les arbres vasculaires. Deuxièmement, nous proposons une méthodologie pour analyser la géométrie des artères en ARM corps entier. La ligne centrale des artères est extraite, et les propriétés géométriques de cette courbe 3D sont calculées, pour améliorer l'interprétation des angiogrammes. Ces techniques sont le point de départ d'une approche plus globale que la procédure conventionnelle d'évaluation de l'athérosclérose, dans l'espoir un jour d'utiliser ces méthodes pour un suivi systématique des maladies vasculaires.<br />Nous avons développé les méthodes que nous présentons dans le but qu'elles soient utilisées dans la pratique clinique. Cependant, elle peuvent potentiellement être utilisées pour d'autres applications de l'analyse d'images.

Page generated in 0.072 seconds