• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 127
  • 76
  • 6
  • 4
  • 4
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 287
  • 128
  • 86
  • 85
  • 70
  • 51
  • 37
  • 29
  • 28
  • 28
  • 27
  • 26
  • 23
  • 22
  • 22
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Proposta de protocolo clínico para utilização do laser de baixa potência em estomatite protética associada a candidose atrópica

MEZZARANE, LILIAN A. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:54:18Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:09:21Z (GMT). No. of bitstreams: 1 12722.pdf: 558008 bytes, checksum: 01284590d84b5a596a55c0b0b7177695 (MD5) / Dissertacao (Mestrado Profissionalizante em Lasers em Odontologia) / IPEN/D-MPLO / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP; Faculdade de Odontologia, Universidade de Sao Paulo, Sao Paulo
82

Estudo de materiais alternativos para aplicacao em sistemas de proteses odontologicas com conexoes magneticas / Alternative materials study for dental magnetics attachments applications

MARQUES, ROGERIO A. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:26:12Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:10:32Z (GMT). No. of bitstreams: 0 / Materiais ferromagnéticos são investigados como possíveis candidatos para aplicações em próteses dentais em substituição aos conectores magnéticos feitos em ligas ferromagnéticas de elevado custo. Neste trabalho, três materiais foram investigados: o aço inoxidável 17-4 PH, confeccionado por moldagem de pós por injeção (PIM), a liga PM2000, obtida por mechanical alloying e endurecida por dispersão de óxidos, e o aço inoxidável 1802, isento de níquel. O ensaio de citotoxicidade in vitro mostrou que nenhum dos três materiais era citotóxico. O comportamento frente à corrosão foi estudado através de curvas de polarização anódica potenciodinâmicas e por espectroscopia de impedância eletroquímica (EIE) em solução tamponada com fosfato (PBS), a 25°C. Como material de referência, foi utilizado o aço inoxidável 316L devido ao seu amplo emprego como biomaterial, principalmente na confecção de próteses ortopédicas. Todos os materiais se mostraram passivos em condições estacionárias, mas apresentaram tendência à corrosão por pite. O que apresentou maior resistência à corrosão por pite foi o PM2000, enquanto o aço 1802 mostrou a maior susceptibilidade a este tipo de corrosão, entre os estudados. Os diagramas de Mott-Schottky indicaram que o filme passivo superficial do aço PM2000 é pelo menos uma ordem de grandeza menos dopado que o filme do aço 316L e, portanto, menos defeituoso. Os resultados apontaram para o PM2000 como um possível candidato para a substituição das ligas nobres ferromagnéticas de alto custo. / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
83

Torque de afrouxamento dos parafusos proteticos em proteses implanto-suportadas com diferentes niveis de desajuste / Loosening torque of prosthetic screws in implante-supported dentures with different fit levels

Spazzin, Aloísio Oro, 1984- 02 December 2009 (has links)
Orientador: Marcelo Ferraz Mesquita / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Campinas / Made available in DSpace on 2018-08-12T19:41:12Z (GMT). No. of bitstreams: 1 Spazzin_AloisioOro_M.pdf: 136206020 bytes, checksum: 3bd1b222bdf09c7c84975da4fc525ca7 (MD5) Previous issue date: 2009 / Resumo: O objetivo neste estudo foi verificar a influência da composição da liga (titânio ou ouro) e do re-aperto no torque de afrouxamento dos parafusos protéticos, sob diferentes níveis de desajustes (adaptação passiva e desajuste) de próteses mandibulares implantosuportadas. Foram confeccionadas 10 próteses totais mandibulares implanto-suportadas e criados dois níveis de desajustes, confeccionando 20 modelos de gesso (n = 10): próteses com adaptação passiva (G1_controle); e próteses com desajuste (G2). Para G1, as estruturas protéticas foram parafusadas diretamente aos análogos de mini-pilares cônicos. Para G2, os desajustes foram simulados utilizando anéis interpostos entre os cilindros da infra-estrutura e os análogos. O objetivo da interposição dos anéis foi obter média de 250 µm de desajuste no teste do parafuso único. Os análogos de todos os conjuntos montados foram incluídos em gesso utilizando delineador. Um microscópio óptico comparador (120x) foi usado para quantificar os valores de desajuste vertical no teste do parafuso único. As estruturas protéticas foram utilizadas para os dois níveis de desajustes. O torque de afrouxamento (TA) foi avaliado utilizando parafusos fabricados em liga de titânio (Ti) ou ouro (Au), sendo avaliadas também duas técnicas de aplicação de torque (10 Ncm): 1) torque e destorque após 24 horas (SR); e 2) torque, retorque após 10 minutos e destorque após 24 horas (CR). Foi utilizado torquímetro digital (TQ8800; Lutron) para aplicação do torque e leitura do TA. Os resultados foram submetidos à análise de variância de dois fatores (ANOVA) seguida do teste de Tukey (a=0,05). Os valores médios de TA (Ncm) para parafusos de Ti foram: G1/SR=6,99(±1,03); G1/CR=7,33(±0,79); G2/SR=5,65(±1,18); G2/CR=7,24(±1,00). Para parafusos de Au foram: G1/SR=5,42(±0,99);G1/CR=5,97(±1,00); G2/SR=5,03(±1,33); G2/CR=5,71(±1,02). No Capítulo-1, os materiais dos parafusos foram comparados sem aplicação do retorque (SR): Ti apresentou valor médio de TA mais elevado, diferindo estatisticamente do de Au no G1; o G2 apresentou menor valor médio de TA, diferindo estatisticamente do G1 para Ti. Não foi encontrada diferença estatística significante entre Ti e Au no G2, ou entre G1 e G2 para Au. No Capítulo-2, o retorque foi avaliado separadamente para Ti e Au. Para parafusos de Ti: o G2/SR apresentou menor valor médio de TA, diferindo estatisticamente do G1/SR; o G2/CR apresentou valor médio de TA mais elevado, diferindo estatisticamente de G2/SR; não foi encontrada diferença no valor médio de TA entre G1/CR e G2/CR, ou entre G1/SR e G1/CR. Para parafusos de Au, os grupos não apresentaram valores médios com diferença estatística entre si. Os materiais dos parafusos protéticos apresentaram comportamento diferente frente aos desajustes e retorque. A estabilidade da conexão dos parafusos de ouro não foi influenciada pelas variáveis avaliadas, enquanto os parafusos de titânio foram mais suscetíveis ao afrouxamento com aumento do desajuste, uma vez que o torque de afrouxamento diminuiu para valores semelhantes aos encontrados para os parafusos de ouro independentemente do nível de desajuste das próteses. Porém, a aplicação do retorque aumentou o torque necessário para afrouxar os parafusos de titânio para valores similares àqueles encontrados em próteses com adaptação passiva. / Resumo: O objetivo neste estudo foi verificar a influência da composição da liga (titânio ou ouro) e do re-aperto no torque de afrouxamento dos parafusos protéticos, sob diferentes níveis de desajustes (adaptação passiva e desajuste) de próteses mandibulares implantosuportadas. Foram confeccionadas 10 próteses totais mandibulares implanto-suportadas e criados dois níveis de desajustes, confeccionando 20 modelos de gesso (n = 10): próteses com adaptação passiva (G1_controle); e próteses com desajuste (G2). Para G1, as estruturas protéticas foram parafusadas diretamente aos análogos de mini-pilares cônicos. Para G2, os desajustes foram simulados utilizando anéis interpostos entre os cilindros da infra-estrutura e os análogos. O objetivo da interposição dos anéis foi obter média de 250 µm de desajuste no teste do parafuso único. Os análogos de todos os conjuntos montados foram incluídos em gesso utilizando delineador. Um microscópio óptico comparador (120x) foi usado para quantificar os valores de desajuste vertical no teste do parafuso único. As estruturas protéticas foram utilizadas para os dois níveis de desajustes. O torque de afrouxamento (TA) foi avaliado utilizando parafusos fabricados em liga de titânio (Ti) ou ouro (Au), sendo avaliadas também duas técnicas de aplicação de torque (10 Ncm): 1) torque e destorque após 24 horas (SR); e 2) torque, retorque após 10 minutos e destorque após 24 horas (CR). Foi utilizado torquímetro digital (TQ8800; Lutron) para aplicação do torque e leitura do TA. Os resultados foram submetidos à análise de variância de dois fatores (ANOVA) seguida do teste de Tukey (a=0,05). Os valores médios de TA (Ncm) para parafusos de Ti foram: G1/SR=6,99(±1,03); G1/CR=7,33(±0,79); G2/SR=5,65(±1,18); G2/CR=7,24(±1,00). Para parafusos de Au foram: G1/SR=5,42(±0,99);G1/CR=5,97(±1,00); G2/SR=5,03(±1,33); G2/CR=5,71(±1,02). No Capítulo-1, os materiais dos parafusos foram comparados sem aplicação do retorque (SR): Ti apresentou valor médio de TA mais elevado, diferindo estatisticamente do de Au no G1; o G2 apresentou menor valor médio de TA, diferindo estatisticamente do G1 para Ti. Não foi encontrada diferença estatística significante entre Ti e Au no G2, ou entre G1 e G2 para Au. No Capítulo-2, o retorque foi avaliado separadamente para Ti e Au. Para parafusos de Ti: o G2/SR apresentou menor valor médio de TA, diferindo estatisticamente do G1/SR; o G2/CR apresentou valor médio de TA mais elevado, diferindo estatisticamente de G2/SR; não foi encontrada diferença no valor médio de TA entre G1/CR e G2/CR, ou entre G1/SR e G1/CR. Para parafusos de Au, os grupos não apresentaram valores médios com diferença estatística entre si. Os materiais dos parafusos protéticos apresentaram comportamento diferente frente aos desajustes e retorque. A estabilidade da conexão dos parafusos de ouro não foi influenciada pelas variáveis avaliadas, enquanto os parafusos de titânio foram mais suscetíveis ao afrouxamento com aumento do desajuste, uma vez que o torque de afrouxamento diminuiu para valores semelhantes aos encontrados para os parafusos de ouro independentemente do nível de desajuste das próteses. Porém, a aplicação do retorque aumentou o torque necessário para afrouxar os parafusos de titânio para valores similares àqueles encontrados em próteses com adaptação passiva. / Abstract: The aim of this study was to verify the influence of alloy composition (titanium or gold) and retightening of the prosthetic screws on the loosening torque of these screws under different misfit levels (passive fit and misfit) of mandibular implant-supported prostheses. Ten mandibular implant-supported prostheses were fabricated. Two misfit levels of the prostheses were obtained fabricating twenty cast models using the prosthetic structures (n=10): prostheses with passive fit (G1_control); and prostheses with misfit (G2). For G1, the prosthetic structures were screwed directly to the analogs. For G2, the misfits were simulated using rings placed between the framework cylinders and the analogs. The analogs of all assembled sets were casted using delineator. The goal of the rings was to obtain mean of 250-µm misfit at one-screw test. An optic microscopic (120x) were used to quantifier the vertical misfit values at the one-screw test. The prosthetic frameworks were used in two misfit levels. The loosening torque (LT) was evaluated using screws made of titanium (Ti) or gold (Au) alloy, two techniques of torque application (10 Ncm) were also evaluated: 1) torque and loosening torque after 24 hours (wR); and 2) torque, retorque after 10 minutes and torque loosening after 24 hours (R). A digital torque meter (TQ8800; Lutron) was used to torque application and to measure the LT. Data were separately analyzed by two-away ANOVA followed by Tukey's test (a=0,05). The LT mean values (Ncm) for titanium screws were: G1/wR=6.99 (±1.03); G1/R=7.33(±0.79); G2/wR=5.65(±1.18); and G2/R=7.24(±1.00). For gold screws were: G1/wR=5.42(±0.99); G1/R=5.97(±1.00); G2/wR=5.03(±1.33); and G2/R=5.71(±1.02). In the Chapter-1, the screw materials were compared without retorque application (wR): Ti showed significant higher LT than Au in the G1; and G2 presented significant lower LT than G1 for Ti. No significant statistic difference was found between Ti and Au in the G2, or between G1 and G2 for Au screws. In the Chapter-2, the retorque was evaluated separately to Ti and Au. For titanium screws: the G2/wR showed lower LT than G1/wR; the G2/R presented higher LT than G2/wR; no significant difference on the LT between G1/R and G2/R; or between G1/wR and G1/R. For gold screws, the groups did not show mean values with statistic difference between each other. The prosthetic screw materials presented different behavior for the misfits and the retorque. The joint stability of the gold screw was not influenced by variables tested. While the titanium screws were more susceptible to the loosening with the misfit increase, once the loosening torque decreased to similar values those found for the gold screws regardless of the prosthetic fit level. However, the torque application increased the loosening torque of the titanium screws to similar values those found to the prostheses with passive fit. / Abstract: The aim of this study was to verify the influence of alloy composition (titanium or gold) and retightening of the prosthetic screws on the loosening torque of these screws under different misfit levels (passive fit and misfit) of mandibular implant-supported prostheses. Ten mandibular implant-supported prostheses were fabricated. Two misfit levels of the prostheses were obtained fabricating twenty cast models using the prosthetic structures (n=10): prostheses with passive fit (G1_control); and prostheses with misfit (G2). For G1, the prosthetic structures were screwed directly to the analogs. For G2, the misfits were simulated using rings placed between the framework cylinders and the analogs. The analogs of all assembled sets were casted using delineator. The goal of the rings was to obtain mean of 250-µm misfit at one-screw test. An optic microscopic (120x) were used to quantifier the vertical misfit values at the one-screw test. The prosthetic frameworks were used in two misfit levels. The loosening torque (LT) was evaluated using screws made of titanium (Ti) or gold (Au) alloy, two techniques of torque application (10 Ncm) were also evaluated: 1) torque and loosening torque after 24 hours (wR); and 2) torque, retorque after 10 minutes and torque loosening after 24 hours (R). A digital torque meter (TQ8800; Lutron) was used to torque application and to measure the LT. Data were separately analyzed by two-away ANOVA followed by Tukey's test (a=0,05). The LT mean values (Ncm) for titanium screws were: G1/wR=6.99 (±1.03); G1/R=7.33(±0.79); G2/wR=5.65(±1.18); and G2/R=7.24(±1.00). For gold screws were: G1/wR=5.42(±0.99); G1/R=5.97(±1.00); G2/wR=5.03(±1.33); and G2/R=5.71(±1.02). In the Chapter-1, the screw materials were compared without retorque application (wR): Ti showed significant higher LT than Au in the G1; and G2 presented significant lower LT than G1 for Ti. No significant statistic difference was found between Ti and Au in the G2, or between G1 and G2 for Au screws. In the Chapter-2, the retorque was evaluated separately to Ti and Au. For titanium screws: the G2/wR showed lower LT than G1/wR; the G2/R presented higher LT than G2/wR; no significant difference on the LT between G1/R and G2/R; or between G1/wR and G1/R. For gold screws, the groups did not show mean values with statistic difference between each other. The prosthetic screw materials presented different behavior for the misfits and the retorque. The joint stability of the gold screw was not influenced by variables tested. While the titanium screws were more susceptible to the loosening with the misfit increase, once the loosening torque decreased to similar values those found for the gold screws regardless of the prosthetic fit level. However, the torque application increased the loosening torque of the titanium screws to similar values those found to the prostheses with passive fit. / Mestrado / Protese Dental / Mestre em Clínica Odontológica
84

"Critérios indicadores de higiene em próteses totais e fatores contribuintes da população geriátrica" / Indicating criteria of hygiene in total próteses and contributing factors of the geriatrical population

Fernanda Aparecida Napolitano 11 July 2006 (has links)
O presente trabalho se propôs a fazer uma avaliação da higiene e saúde orais de pacientes geriátricos portadores de próteses totais. Devido ao crescimento da população idosa houve um aumento do número de pacientes que passaram a usar algum tipo de prótese (total, removível ou implantes). Espera-se que as próteses totais restituam as funções estéticas, mastigatórias e fonéticas, no entanto sua instalação não representa o final da reabilitação protética, existindo a necessidade da realização de controles periódicos. Um dos fatores essenciais para o sucesso do tratamento odontológico é a higienização eficiente, capaz de remover o biofilme das próteses. Em casos de estomatite protética associada à Cândida ssp, as medidas terapêuticas mais eficientes são os controles efetivos da higiene oral, assim como das próteses (HEARTWELL; RAHN, 1993). Partindo desse raciocínio, o índice de placa nas faces interna e externa das próteses totais maxilares foi avaliado, neste trabalho, através do uso de evidenciadores. Esse procedimento foi realizado em próteses novas tendo-se a preocupação de orientar, no momento da instalação, os portadores das mesmas sobre cuidados de higienização da cavidade oral e das próteses. Foi realizado ainda exame citológico do palato desses mesmos pacientes a fim de verificar a presença de Cândida albicans. Os resultados encontrados não mostraram diminuição dos índices de biofilme depositados nas próteses totais maxilares tanto dos pacientes do grupo experimental como dos pacientes do grupo controle, sendo que se procurou avaliar também distúrbios cognitivos. Estes resultados sugerem que o método de motivação não foi eficiente e que fatores psicológicos, sociais e culturais influenciam a motivação dos pacientes em relação a hábitos de saúde oral. / This research intended to evaluate hygiene and oral health in geriatric patients using complete dentures. Because the elderly population has increased fast much more people uses today some kind of prostheses (complete, removable or implants). It’s expected that complete dentures should replace facial expression, mastigatory function and speech as well. However this is not always possible because patients are supposed to accept the inconvenience and responsibility of taking care of their own prostheses. A very important step is to perform a good hygiene intending to control biofilm development on tooth surface as well as over the prostheses. In Candida-associated denture stomatites the most important therapeutic measure is institution of effective oral and denture hygiene (HEARTWELL; RAHN, 1993). Based on what was mentioned before it was analyzed by means of staining, the biofilm index in the internal and external faces of complete dentures. Such procedures were performed in the new prostheses after instructing the patient how to clean them. It was also performed a cytologic exam of the palatal mucosa to verify if Candida albicans were present, or not. The results did not show any diminution of the biofilm index accumulate in the maxillary prostheses of both groups: control and experimental with or without deficit of cognition. Such results suggest that the motivation method was not efficient and also that psychologic, social and cultural factors do influence the patient’s motivation when we deal with oral health.
85

Efeito do desajuste marginal, tipo de soldagem e material do parafuso sobre a força de destorque de parafusos protéticos e tensões induzidas aos pilares / Effect of marginal misfit, welding type and screw material on the strength of the detorque prosthetic screws and stress induced the abutments

Rodrigues, Sabrina Alessandra, 1986- 20 August 2018 (has links)
Orientador: Marcelo Ferraz Mesquita / Texto em português e inglês / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-20T10:21:04Z (GMT). No. of bitstreams: 1 Rodrigues_SabrinaAlessandra_M.pdf: 1119923 bytes, checksum: 0658dc800fd1f207e56523b3a09bd2e2 (MD5) Previous issue date: 2012 / Resumo: O objetivo neste estudo foi analisar as tensões induzidas aos análogos de pilares protéticos, utilizando-se strain gauges; e avaliar a força de destorque de parafusos protéticos (ouro e titânio) em infraestruturas fundidas em titânio comercialmente puro (Ti cp), antes e após os procedimentos de soldagem laser e TIG (tungsten inert gas). Foram confeccionadas vinte infraestruturas fundidas em titânio comercialmente puro (Ti cp), simulando uma prótese fixa de três elementos; vinte modelos índex com análogos de pilares protéticos modificados para desenvolvimento da análise de tensão e vinte modelos índex com análogos de pilares protéticos convencionais para realização das soldagens e avaliação da força de destorque de parafusos protéticos. Os dois tipos de modelos índex foram confeccionados simulando desajuste marginal vertical de aproximadamente 200 'mi'm. A mensuração do nível de desajuste marginal vertical das infraestruturas foi realizada em microscópio de precisão, por meio do teste do parafuso único (antes e após a soldagem). As soldagens seguiram os seguintes parâmetros: Laser (370V/9ms), TIG (3:36A/2: 60 ms). As tensões induzidas nos análogos modificados de pilares protéticos foram avaliadas por análise extensométrica, utilizando-se strain gauges (antes e após as soldagens). O torque dos parafusos de ouro e titânio foi realizado utilizando-se a técnica de torque (10 N cm) e retorque (10 N cm), após 10 minutos. O destorque dos parafusos foi realizado após 10 minutos do retorque, utilizando-se torquímetro digital. Os resultados foram analisados estatisticamente (ANOVA/Tukey (?=0,05) e teste de correlação de Pearson). Observou-se redução dos níveis de desajuste marginal vertical das infraestruturas, após os procedimentos de soldagem (laser e TIG). Quanto aos níveis de tensão induzidos aos análogos de pilares protéticos pós-soldagem, foram menores para soldagem a laser quando comparados à TIG. Em relação ao destorque dos parafusos, após as soldagens, a força de destorque dos parafusos de ouro foi menor em relação a força de destorque dos parafusos de titânio, que aumentou após os procedimentos de soldagem. Não houve correlação entre desajuste marginal, tensão e força de destorque. Assim, conclui-se que o procedimento de soldagem a laser foi mais eficaz na melhora da adaptação das infraestruturas de três elementos implantossuportadas, quando comparado ao procedimento de soldagem a TIG; e que a os parafusos protéticos de titânio podem ser considerados mais estáveis que os parafusos protéticos de ouro quando torqueados em próteses que possuem satisfatória adaptação / Abstract: The aim of this study was to evaluate the stress induced to analogs of prosthetic abutment using strain gauges and to analyze the detorque strength of prosthetic screws (gold and titanium) of frameworks casted in commercially pure titanium (cp Ti) before and after laser and TIG (tungsten inert gas) welding procedures. Twenty frameworks were made simulating a three-element fixed prosthesis. Twenty index models with modified analogs of prosthetic abutments were obtained for stress analyses and twenty index models with conventional analogs of prosthetic abutments for welding (laser e TIG) and detorque analyses of the prosthetic screws. Both index models were made with 200 'mi'm vertical marginal misfit. An optic microscope was used to measure the vertical marginal misfit following the single-screw test protocol. The welding parameters were the following: laser welding (370V/9ms), TIG welding (3: 36A/2: 60ms). The stress induced on the analogs was evaluated through of the extensometric analysis using strain gauges (before and after welding). The torque of gold and titanium screws was performed with torque (10 Ncm) and retorque (10 Ncm) after 10 minutes. The detorque of the prosthetic screws was performed 10 minutes after the retorque using a digital torquemeter. The results were statistically analyzed (ANOVA/Tukey test (?=0.05)/ Pearson correlation test). A decrease in the levels of vertical marginal misfit was observed after the welding procedures (laser and TIG). Regarding the stress, after the welding procedures, stress levels were lower using laser welding than the TIG. The detorque values were lower for the gold screws than the titanium ones, which presented increased destorque values after welding procedures. There was no correlation between marginal misfit, stress and detorque strength. Thus, it can be concluded that the laser welding procedure was more effective for the improvement of adaptation of three-element implant-supported frameworks, when compared to TIG; and that titanium prosthetic screws can be considered more stable than the gold prosthetic screws when torqued in prostheses that present adaptation satisfactory / Mestrado / Protese Dental / Mestre em Clínica Odontológica
86

Aspects of bone sugar biology:pectin nanocoatings of hard tissue implants

Kokkonen, H. (Hanna) 24 November 2009 (has links)
Abstract The improvement of implant biocompatibility is constantly under investigation. Titanium is a standard biomaterial that performs well in dental and orthopedic implantations. However, detrimental adverse effects resulting from e.g. biomaterial properties, inflammatory responses and surgical procedures occasionally occur. Coating the biomaterials aims at increasing the proportion of successful operations. Pectins, large plant cell wall polysaccharides, are innovative, modifiable, and potentially anti-inflammatory candidates for biomaterial nanocoatings. In this thesis, covalently-grafted pectin fragments (modified hairy regions, MHRs) modified either in vitro (from apple) or in vivo (from potato) were tested. Cell culture vessels and titanium substratum coated with the apple-MHRs, MHR-A and a further-tailored fragment type, MHR-B, were compared with controls for their ability to support proliferation and differentiation of osteoclasts and osteoblasts. Cells grew and differentiated on MHR-B and on the control surfaces; MHR-A did not perform well in these assays. Genetically-engineered potato MHRs did not support bone cell growth to the same extent as apple MHR-B, but nonetheless the possibility to manipulate cellular proliferation with specific in vivo – modifications of pectins was introduced. When implanted into rat soft tissues, neither of the apple MHRs provoked severe acute inflammatory reactions, which indicates good in vivo - tolerance of these botanical macromolecules. These studies illustrate the biocompatibility of MHRs, and the directions towards which they could be further tailored. In terms of clinical use, their tolerability in vivo is especially significant.
87

The use of magnets in biomedical applications

Riley, Melissa Alessandra January 2000 (has links)
No description available.
88

Desempenho biomecânico de sistemas de barra para retenção adicional de sobredentaduras : análise de elementos finitos / Biomechanical performance of overdenture-retaining bar system: finite element analysis

Spazzin, Aloísio Oro, 1984- 02 May 2013 (has links)
Orientador: Lourenço Correr Sobrinho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-22T04:13:28Z (GMT). No. of bitstreams: 1 Spazzin_AloisioOro_D.pdf: 2599609 bytes, checksum: 3bc29d307ef5b6eeccc41da825aaec01 (MD5) Previous issue date: 2013 / Resumo: Neste estudo foram avaliados os efeitos da amplificação do desajuste horizontal, material e formato da secção transversal da barra, e da reabsorção óssea peri-implantar na distribuição das tensões estáticas em um sistema de barra para retenção adicional de sobredentaduras utilizando o método dos elementos finitos. Para a análise computacional, foi criado um modelo tridimensional incluindo dois implantes de titânio e uma barra metálica colocada na região anterior de uma mandíbula severamente reabsorvida. Quatro diferentes ligas (ouro, prata-paládio, cobalto-cromo e titânio comercialmente puro) e três diferentes formatos da secção transversal (circular, ovoide e Hader) da barra foram avaliados. Uma região anterior de mandíbula simulando uma reabsorção óssea peri-implantar de 1,4 mm de altura foi também criada. Os modelos foram exportados para programas de simulação mecânica, em que deslocamentos foram aplicados simulando distorção da barra que sofreu contração durante os procedimentos laboratoriais. Quatro análises foram realizadas, separadamente, para reduzir a quantidade de modelos envolvidos: Capítulo 1 - i) diferentes desajustes horizontais (10, 50, 100, e 200 ?m) utilizando liga de ouro como material da barra; ii) diferentes materiais da barra simulando 50 ?m de desajuste horizontal (neste capítulo foi utilizada barra de secção transversal circular); Capítulo 2 - iii) diferentes secções transversais da barra simulando diferentes desajustes horizontais (10, 50 e 100 ?m); iv) diferentes secções transversais da barra simulando 1,4 mm de reabsorção óssea peri-implantar e 50 ?m de desajuste horizontal (neste capítulo foi utilizado liga de cobalto-cromo como material da barra). Os dados foram analisados por meio de figuras e dados numéricos gerados pelos programas. A amplificação do desajuste horizontal aumentou os níveis de tensões estáticas nas estruturas do sistema. Materiais mais rígidos e geometrias mais complexas da barra aumentaram os níveis de tensões estáticas no sistema de barra quando desajustes horizontais estão presentes. A reabsorção óssea simulada aumentou a deformação e a concentração de tensões no tecido ósseo peri-implantar quando desajustes horizontais estão presentes / Abstract: In this study were evaluated the effects of horizontal misfit amplification, material and cross-section geometry of the bar, and peri-implant bone loss on the distribution of static stresses in an overdenture-retaining bar system using finite element analysis. For the computational analysis, a three-dimensional model was created including two titanium implants and a metallic bar placed in the anterior part of a severely resorbed jaw. Four different alloys (gold, silver-palladium, cobalt-chromium, and commercially pure titanium) and three different cross-section geometries (circular, ovoid and Hader) of the bar were evaluated. An anterior part of jaw simulating a peri-implant bone loss of 1.4 mm height was also created. The models were exported to mechanical simulation software, where horizontal displacements were applied simulating the settling of the bar that suffered shrinkage during laboratory procedures. Four analyses were carried out, separately, to reduce the quantity of involved models: Chapter 1 - (i) different horizontal misfits (10, 50, 100, and 200 ?m) using gold alloy as bar material; (ii) different bar materials simulating 50-?m misfit horizontal (circular cross-section of the bar was used in this chapter); Chapter 2 - (iii) different cross-section geometries of the bar simulating different horizontal misfits (10, 50 and 100 ?m); (iv) different cross-section geometries of the bar simulating 1.4-mm peri-implant bone loss and 50-?m horizontal misfit (cobalt-chromium alloy was used as bar material in this chapter). Data were analyzed using figures and numerical data generated by software. The amplification of the horizontal misfit increased the levels of static stress in the structures of the system. Stiffer materials and more complex geometries of the bar increased the levels of static stress on bar system when horizontal misfits are present. The bone loss simulated increased the strain and stress concentration in the peri-implant bone tissue / Doutorado / Materiais Dentarios / Doutor em Materiais Dentários
89

Influência do número de implantes no comportamento biomecânico de overdentures mandibulares : análise fotoelástica / Number of implant influence on the biomechanical behavior of mandibular overdentures : photoelastic stress analysis

Campana, Júlia Trevizam, 1989- 27 August 2018 (has links)
Orientador: Rafael Leonardo Xediek Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-27T08:10:23Z (GMT). No. of bitstreams: 1 Campana_JuliaTrevizam_M.pdf: 13654859 bytes, checksum: 968de9ae31cd28485a92b1f5b52edc6c (MD5) Previous issue date: 2015 / Resumo: O objetivo neste estudo in vitro foi avaliar por meio da análise fotoelástica o comportamento das tensões induzidas em diferentes overdentures. Os grupos experimentais foram: I- overdenture retida por um implante colocado na linha média da mandíbula; II- overdenture retida por dois implantes distantes 20 mm entre si; III- overdenture retida por três implantes, com o central colocado na linha média da mandíbula e os restantes distantes 18 mm de cada lado; e IV- overdenture retida por quatro implantes distantes 12 mm entre si. Para o estudo foi confeccionada uma prótese overdenture mandibular para cada grupo experimental e uma prótese total superior convencional, possibilitando que a análise fotoelástica fosse conduzida com as próteses se relacionando em máxima intercuspidação habitual. Foram feitos carregamentos axiais de 10, 20 e 30 kgf em cada modelo fotoelástico mandibular. Também foi realizado carregamento na oclusal dos primeiros molares direito e esquerdo de cada modelo com mesma intensidade de carga, para simular o efeito da mastigação. Dois tipos de avaliação foram conduzidos: qualitativa, por meio da análise das imagens obtidas com fotografias do modelo em polariscópio, e quantitativa, com as imagens analisadas no programa FRINGES. A análise qualitativa mostrou que a distribuição das tensões no Grupo I foi diferente dos Grupos II, III e IV, com maior quantidade de franjas concentradas na região posterior da mandíbula. O grupo IV apresentou melhor distribuição de tensão quando comparado aos Grupos II e III. Na análise quantitativa, a overdenture retida por um implante (Grupo I) mostrou valores de tensão similares aos Grupos II, III e IV. Com base nesses resultados pode-se concluir que: em todas as overdentures a tensão se concentrou predominantemente ao redor dos implantes; o aumento do carregamento oclusal ou pontual promoveu aumento das tensões induzidas sobre os implantes; maior tensão foi induzida no lado da aplicação da carga pontual, principalmente, quando a overdenture era suportada por um implante, e a concentração da tensão em overdenture suportada por maior quantidade de implante mostrou distribuição mais homogenia das tensões induzidas / Abstract: The aim of this in vitro study was to evaluate through photoelastic analysis the behavior of the induced stress in different overdentures. The experimental groups were: I- overdenture retained by one implant placed in the midline of the mandible; II- overdenture retained by two implants 20 mm distant from each other; III- overdenture retained by three implants, with the center placed on the midline of the mandible and the other distant 18 mm on each side; and IV- overdenture retained by four implants 12 mm distant from each other. For the study was made a prosthetic mandibular overdenture for each experimental group and a conventional complete denture, allowing the photoelastic analysis was conducted with the dentures related in maximum intercuspation. Axial loads of 10, 20 and 30 kgf were made in each mandibular photoelastic model. It was also performed on the occlusal loading of the first left and right molars of each model with similar load intensity to simulate the effect of mastication. Two types of evaluation were conducted: qualitative, by analyzing the images from photographs obtained with polariscope, and quantitative, with the images analyzed by the FRINGES program. Qualitative analysis showed that the distribution of tensions in Group I was different from the Groups II, III and IV, showing a higher amount of concentrated fringes on the posterior region of the mandible. Group IV showed better stress distribution when compared to Groups II and III. In the quantitative analysis, the overdenture retained by implant (Group I) showed similar stress values for Groups II, III and IV. Based on these results, it can be concluded that in all overdentures the stresses focused predominantly around the implants; increased single and occlusal loading promoted an increase of induced stresses on the implants; higher stress was induced on the application side, especially when the overdenture was supported by one implant; and stress concentration in overdenture supported by a larger amount of implantation showed more homogeneous stress distribution / Mestrado / Protese Dental / Mestra em Clínica Odontológica
90

The effects of orthopedic pathologies on the prevalence of hip osteoarthritis

Sanchez, Aubrie M. 14 June 2019 (has links)
Osteoarthritis (OA) is a degenerative joint disease that is a leading cause of disability among aging adults. In the U.S., many individuals living with total hip arthroplasties attribute OA as the cause. Because the majority of anthropological OA research excludes pathological individuals (i.e., individuals with systemic disease, traumatic injuries, or arthroplasties), little is known about how prostheses and pathologies impact OA. This project adds to the research surrounding OA by investigating its relationship with age, disease, and prostheses. The proximal femora of 186 African- and European-American individuals (21-95 years old) from the Edmonds Orthopedic Pathology Collection (National Museum of Health and Medicine; Armed Forces Institute of Pathology) were analyzed. These individuals were grouped into three cohorts: non-disease; disease; and previous injury/prosthesis. Jurmain’s (1990) method was used to score OA, using an ordinal fourpoint scale to categorize OA changes as: none/slight; moderate; severe; and ankylosis. Results show that osteoarthritic hip changes are positively correlated with age and presence of a prosthesis, and that systemic diseases, such as cancer, increase the likelihood of OA in an individual. Results from Chi-square tests, exploratory data analysis, and ordinal logistic regression show that there is a statistically significant relationship (p<0.000) between degree of OA, age, recorded disease, and evidence of previous injury or prostheses. In contrast with the expectation that different populations would exhibit different patterns of OA, no sex or ancestry effects are observed. These results will help researchers better understand the etiology and contemporary risk factors of OA, as well as contribute data to OA research on an underrepresented sample.

Page generated in 0.0365 seconds